Response characteristics of an imaging plate to clinical proton beams

Similar documents
Measurement ofdepth-dose distribution ofprotons by an imaging plate

THE mono-energetic hadron beam such as heavy-ions or

Chapter V: Cavity theories

A Correction Factor for Effects of Scattered X-rays at Calibration of Ionization Chambers in Low Energy X-ray Standard Fields

Author's personal copy

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Monte Carlo Simulation concerning Particle Therapy

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

Precision neutron flux measurement with a neutron beam monitor

PHITS calculation of the radiation field in HIMAC BIO

A Monte Carlo Study of the Relationship between the Time. Structures of Prompt Gammas and in vivo Radiation Dose in.

Instrumentation for Verification of Dose

Radiation protection issues in proton therapy

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Development of beam delivery systems for proton (ion) therapy

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Instrumentation for Verification of Dose

The scanning microbeam PIXE analysis facility at NIRS

Position sensitive detection of thermal neutrons with solid state detectors (Gd Si planar detectors)

Monte Carlo simulations of ripple filters designed for proton and carbon ion beams in hadrontherapy with active scanning technique

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

R&D of emulsion technology to study fragment interaction to improve ion therapy

Measurement of induced radioactivity in air and water for medical accelerators

Radiation Dosimetry. Electron interactions with matter. Important processes in radiotherapy. Contents. Alun Beddoe

Simulation Modeling in Dosimetry

Estimating proton beam energy spread using Bragg peak measurement

Radionuclide Imaging MII Detection of Nuclear Emission

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

New irradiation zones at the CERN-PS

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Secondary Particles Produced by Hadron Therapy

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Repeatability of Spectral Intensity Using an Auger Electron Spectroscopy Instrument Equipped with a Cylindrical Mirror Analyzer

Physics of Particle Beams. Hsiao-Ming Lu, Ph.D., Jay Flanz, Ph.D., Harald Paganetti, Ph.D. Massachusetts General Hospital Harvard Medical School

Laser-Accelerated protons for radiation therapy

Dosimetry for space radiation in ISS lifescience experiments using PADLES system

anti-compton BGO detector

In our recent paper [1], applicability of the self-activation of an NaI scintillator has been studied for the photo-neutron monitoring around

Radiation Dose, Biology & Risk

9. Application to Proton Therapy

1.E Neutron Energy (MeV)

The development of new generation electronic personal dosimeters

Electrostatic charging e ects in fast H interactions with thin Ar

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Radiation Protection & Radiation Therapy

Estimation of Radioactivity and Residual Gamma-ray Dose around a Collimator at 3-GeV Proton Synchrotron Ring of J-PARC Facility

Physics of particles. H. Paganetti PhD Massachusetts General Hospital & Harvard Medical School

Development of New MicroStrip Gas Chambers for X-ray Applications

CHARGED PARTICLE INTERACTIONS

Outline. Radiation Interactions. Spurs, Blobs and Short Tracks. Introduction. Radiation Interactions 1

INTERACTIONS OF RADIATION WITH MATTER

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Development of a Silicon PIN Diode X-Ray Detector

Radiation Detection and Measurement

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

Characterization of Low-Energy (6-30 kev) Response of Polish TLDs (MTS-N, MCP-N) with Synchrotron Radiation and Determination of Some TLD Quantities.

General Physics (PHY 2140)

General Physics (PHY 2140)

Stopping power for MeV 12 C ions in solids

Initial Studies in Proton Computed Tomography

arxiv: v2 [physics.med-ph] 29 May 2015

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Electron transparency, ion transparency and ion feedback of a 3M GEM

Introduction. X-Ray Production and Quality. Fluorescence Yield. Fluorescence X-Rays. Initiating event. Initiating event 3/18/2011

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Heavy ion fusion energy program in Russia

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

2 Improvements of Programs 2.1 L-X ray Energy dependent L subshell cross sections In 1996 version of L-X ray calculation [5], the ratio of L sub

Personal Dose Monitoring System

Absorption spectra variations of EBT radiochromic film from radiation exposure

FLUKA simulations of selected topics regarding proton pencil beam scanning

COMPARISON OF COMPUTER CODES APPLICABILITY IN SHIELDING DESIGN FOR HADRON THERAPY FACILITIES *

Tritium measurement using a photo-stimulable phosphor BaFBr(I):Eu 2+ plate

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

Characterization of heavy charged particle fields using fluorescent nuclear track detectors

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Multi-Purpose Accelerator-Accumulator ITEP-TWAC for Nuclear Physics and Practical Applications

SIMULATION OF COMPETING FADING AND IRRADIATION EFFECTS IN THERMOLUMINESCENCE (TL) DOSIMETRY: 1 st ORDER KINETICS

Ultrafast X-Ray-Matter Interaction and Damage of Inorganic Solids October 10, 2008

The heavy ion irradiation facility at KVI-CART

TRITIUM PRODUCTION IN PALLADIUM DEUTERIDE/HYDRIDE IN EVACUATED CHAMBER

City University of Hong Kong

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

At the conclusion of this lesson the trainee will be able to: a) Write a typical equation for the production of each type of radiation.

Atoms, Radiation, and Radiation Protection

The electron accelerator of the ISOF-CNR Institute: its characteristics and use

SLAC-PUB Submitted to Radiation Protection and Dosimetry. Work supported by Department of Energy contract DE-AC02-76SF00515

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

APPLIED RADIATION PHYSICS

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

Transcription:

Nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 Response characteristics of an imaging plate to clinical proton beams A. Nohtomi *, T. Terunuma, R. Kohno, Y. Takada, Y. Hayakawa, A. Maruhashi, T. Sakae Institute of Applied Physics, University of Tsukuba, Ten-nohdai 1-1-1, Tsukuba 305-8573, Japan Proton Medical Research Center (PMRC), University of Tsukuba, Ten-nohdai 1-1-1, Tsukuba 305-8575, Japan Institute of Basic Medical Science, University of Tsukuba, Amakubo 2-1-1, Tsukuba 305-8575, Japan Institute of Clinical Medicine, University of Tsukuba, Amakubo 2-1-1, Tsukuba 305-8575, Japan Received 6 July 1998; received in revised form 2 November 1998 Abstract For an application to a dose-distribution measurement, the response of an imaging plate (IP) has been studied with proton beams which are routinely utilized for the radiation therapy. The upper limit of measurable proton dose by an IP system is primarily controlled by the readout range of the scanner that is used. Within this limit, reasonable linear response of an IP to proton dose to water is maintained. Fading curves are neither sensitive to a small change of room temperature (22 26 C) nor to a variation of proton dose (0.0108 0.132 Gy). Reproducibility of the PSL intensity is fairly good if both the fading characteristics and the lot-dependence of the sensitivity of each IP are taken into account carefully. Stopping power dependence of the IP response has been examined at different positions in a Bragg curve. 1999 Elsevier Science B.V. All rights reserved. Keywords: Clinical proton beam; Imaging plate (IP); Dose distribution; Fading characteristics; Stopping power dependence 1. Introduction In the charged particle therapy, it is necessary to verify the achievement of expected dose distribution prior to the actual irradiation to patients. This is usually a quite time-consuming task with a small single detector. Therefore, a multi-dimensional * Corresponding author. Fax: #81 0298 64 2575; e-mail: nohtomi@medaxp.kek.jp. dosimeter is much desirable for such routine measurement [1,2]. An imaging plate (IP) system has been widely used in many fields as a two-dimensional detector for radiations owing to a large sensitive area and a high spatial resolution. The first application of an IP to proton dose-distribution measurement was carried out by Hayakawa et al. [3]. Using clinical proton beams, they showed that the linearity between the intensity of photo-stimulated luminescence (PSL) and proton dose to water was 0168-9002/99/$ see front matter 1999 Elsevier Science B.V. All rights reserved. PII: S 0 1 6 8-9 0 0 2 ( 9 8 ) 0 1 3 8 7-4

570 A. Nohtomi et al./nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 maintained up to 0.013 Gy. As a demonstration of the stopping power dependence, they measured a depth-dose distribution of an ordinary Bragg peak by an IP, which was found to be roughly proportional to that measured by a Si diode. Weissman et al. [4] successfully used an IP to measure the profile of a 600 kev proton beam in vacuum. In this paper, the application of IPs for proton beams has been extended with the aim of realization of a practical dosimetry system for therapy. Linearity between PSL intensity and proton dose has been measured to search the practical upper limit of measurable dose. Fading characteristics, the lot dependence and the stopping power dependence have been investigated for quantitative dose evaluation. 2. Proton dosimetry with imaging plates In the clinical dosimetry, ionization chambers are the primary dose measuring devices. In addition to this, other types of detectors have been successfully used to measure the dose deposited by heavy charged particles: such as diodes, thermoluminescent dosimeters (TLDs) and chemical dosimeters [5]. An IP can be a candidate for such application. Actually, in early days, a kind of PSL material, SrS-Eu,Sm, was studied as a dosimeter by Antonov-Romanovsky et al. (1955) [6]. A PSL sheet of the IP tested in the present work (BAS-III 2025, Fuji Film Co., Ltd.) is made of BaFBr : Eu. The sensitive layer is very thin, 100 150 μm, effectively less due to the attenuation of the stimulating light and its PSL with penetration. Therefore, all the energetic protons of a few MeV or more pass through the sensitive region, while low energy protons stop in it. For this complicated fact, response of IPs to clinical proton beams may not be so simple. On the other hand, however, similar situation is found in the dosimetry with TLDs; very small size of TLD plates whose thickness are a few hundred μm are often used for the precise determination of spatial dose distribution. As TLD dosimetry has been used to characterize the therapeutic heavy charged particles, we expect that proton dosimetry with IPs would be useful for the verification of dose distribution. 3. Apparatus and experimental setup Proton irradiation was carried out using the horizontal beam line of Proton Medical Research Center (PMRC), University of Tsukuba. In this beam line, approximately monoenergetic 250 MeV protons are delivered from the KEK 500 MeV booster synchrotron with the aid of a carbon energy-degrader and a momentum analyzing system. Delivered proton beams have a sharply-bunched time structure; each pulse consists of about 2 4 10 protons with a duration time of 50 ns in fwhm. The pulse frequency was about 1 Hz in the present experiment condition. Firstly, the incident protons were scattered by a 3 mm-thick lead plate (referred as first scatterer ) to obtain laterally uniform spatial distribution. Between the first scatterer and a patient bed, some beam shaping devices and beam monitors were inserted, if necessary: i.e. a binary range shifter, a ridge filter, a field collimator and a secondary-emission chamber (SEC) monitor. Imaging plates sandwiched by Mix-DP plates were put on the patient bed; the sensitive sides were faced toward the beam-coming direction. A thimble ionization chamber (TIC), JARP C110, 0.2 ml, was arranged just near the imaging plates to measure protons; the reading was evaluated as proton dose to water with a correction of recombination effect. The sensitivity of the TIC had been calibrated in a Co γ-ray standard field in advance. Twenty sheets of IPs (BAS-III 2025, Fuji Film Co., Ltd.) were used in the present work. Those IPs were classified into two groups for the sake of lot-dependence consideration: i.e. Group-A (serial No. 17745 17754) and Group-B (serial No. 17537 17546). Before each irradiation, latent images were erased off. During irradiation, each plate was kept inside a black thin vinyl bag. The scanner used was BAS2000-II (Fuji Film Co., Ltd.) with fixed scanning parameters of Latitude "4, Sensitivity "400 and Resolution "200 μm. The upper limit of measurable PSL intensity in this setting is 10 PSL/mm [7]. This is maximum one for BAS2000-II operation.

A. Nohtomi et al./nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 571 4. Results and discussion 4.1. Linearity of PSL intensity to proton dose Photo-stimulated luminescence intensity was measured for various proton doses from 0.003 Gy (1 pulse) to 0.240 Gy (75 pulses). The experimental setting is sketched in Fig. 1. A ridge filter was used to form a 70 mm iso-dose region in depth, spreadout Bragg peak (SOBP). An IP was placed in the SOBP. At this position, the maximum residual range of protons was about 50 mm in water, which corresponds to about 80 MeV of proton energy. On the other hand, because the iso-dose region is created by stacking some Bragg peaks of different range beams, the minimum proton energy must be almost 0 MeV at all points inside SOBP. Stored images were readout 90 min after the termination of each irradiation. As shown in Fig. 2, the PSL intensity is proportional to proton dose up to 0.148 Gy at least. At 0.224 and 0.24 Gy, readout PSL intensity reaches the upper limit of scanner range, 10 PSL/mm. It seems that the upper limit of measurable dose is controlled by the scanner range in this measurement. The PSL intensity in Fig. 2 is about twice as large as the one of Fig. 2 in Ref. [3]. The discrepancy is due to the following reasons. First of all, different amounts of fading of stored images occurred between both measurements. In Ref. [3], images were readout about 1 day after the irradiation. Secondly, the sort of scanner used in Ref. [3] was not identical with the present one. In addition, the sensitivity of IP used in Ref. [3] is unknown and may be somewhat different from that used here. 4.2. Fading characteristics It is known that the latent image of radiation stored in an IP fades as time goes by: so-called fading. Fading curves have been reported for α-rays [8,9], β-rays [9], γ-rays [10 12], X-rays [13,14] and electron beams [15]. The fading is essentially important for dosimetry with IPs. Fading characteristics up to 200 min after irradiation were measured for various proton dose to water, 0.0108 0.132 Gy, under some temperature conditions, 22 26 C. The experimental arrangement was almost the same as that in Fig. 1. In this measurement, however, 7 10 sheets of IPs were stacked against each other and inserted into the SOBP region; the influence of such stack configuration was carefully examined and found to be negligible for the present purpose. Protons were irradiated to those IPs simultaneously and each IP was readout after a certain duration to obtain the PSL intensity. This procedure was repeated and eight fading curves were evaluated. Those curves were normalized by the PSL intensity per proton Fig. 1. Arrangement for the measurement of linearity and fading characteristics of the IPs.

572 A. Nohtomi et al./nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 Fig. 3. Normalized fading curves of PSL intensity. Fig. 2. Linearity of PSL intensity to proton dose to water measured in an SOBP. dose at the termination of irradiation (t"0 min), I (PSL/mm /Gy), and plotted in Fig. 3. Before the normalization by I, a systematic difference of IP sensitivity was observed between two lot-groups in those fading curves. In Fig. 3, all experimental data can be fitted well by a combination of two exponential curves with different time constants. This means that obtained fading characteristics are neither so sensitive to a small change of room temperature (22 26 C) nor to a certain variation of irradiated proton dose (0.0108 0.132 Gy). A result of data fitting with two exponential decay functions gives the following equation: I/I "0.25 exp((!ln 2) t/15.5) #0.75 exp((!ln 2) t/3400). This fading curve (I/I ) consists of two components with half-lives of 15.5 min (25%) and 3400 min (75%). 4.3. Proton stopping power dependence Hayakawa et al. roughly demonstrated that an imaging plate is useful for the measurement of depth-dose distribution of a Bragg curve [3]. However, a direct and precise comparison of IP response with proton dose to water has not been carried out yet by using ionization chambers. A Bragg curve was measured with IPs by changing a binary range shifter which was arranged at about 3 m upstream of the patient bed instead of the ridge filter in Fig. 1. The proton dose to water was measured by the TIC which was put just in front of the IP. The SEC was used as a reference monitor in order to compensate the slight beamintensity fluctuation during irradiation. The dose by γ-rays was measured with film badges near the IP position and estimated to be less than 0.01% of irradiated proton dose. Therefore, PSL signal due to γ-rays from the range shifter was negligible. Fig. 4 shows the obtained data with different detectors, IP and TIC, as a function of the thickness of the range shifter. Each curve is normalized so that their plateaus come to the same level. As indicated in the figure, there is notable disagreement between the two curves beyond the peak position of Bragg curve. It should be kept in mind that the shapes of both Bragg curves are slightly distorted from the real dose distribution at the proximal region. This may be due to a scattering effect by the insertion of range-shifting material and use of thick dosimeters. In Fig. 4, the ratios of PSL intensity to proton dose measured by TIC are also plotted. That is normalized at the range-shifter thickness of 55 mm. From 0 to 190 mm, the ratio is kept almost constant. On the other hand, more than 190 mm, it decreases with approaching the distal edge. Similar

A. Nohtomi et al./nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 573 Fig. 4. Bragg curves obtained by the TIC and IPs. The ratios of IP signals relative to the dose measured by TIC are also plotted. Fig. 5. Depth dose profiles of an SOBP measured in a water phantom with TIC and IPs. The response of IP is calculated from the result in Fig. 4.

574 A. Nohtomi et al./nuclear Instruments and Methods in Physics Research A 424 (1999) 569 574 phenomenon has been observed in TLD dosimetry of heavy ion beams [16]. By using the result of Fig. 4, response of IPs can be predicted for an SOBP formed by a known ridge filter. As shown in Fig. 5, the distribution of measured PSL intensity shows a good agreement with calculated one. This means actual depth dose distribution should agree with the physical dose distribution expected from the ridge filter used. Such procedure is applicable to verify the planning algorithms. 5. Summary The upper limit of measurable proton dose by an IP system is primarily controlled by the readout range of the scanner used. For the irradiation of clinical dose level (a few Gy), PSL intensity exceeds the scanner limit. When stored images are read out 90 min after irradiation, reasonable linear response of an IP to proton dose to water is ascertained up to about 0.15 Gy. Fading curves are not sensitive to a small change of room temperature (22 26 C) or to a variation of proton dose (0.0108 0.132 Gy). As far as the measurements repeated in the present work are concerned, reproducibility of the PSL intensity seems to be fairly good if both the fading characteristics and the lot-dependence of the sensitivity of each IP are taken into account with caution. Stopping power dependence of the IP response must be considered very carefully for the quantitative evaluation of dose profiles. For proton dosimetry with IPs, it is necessary to check and control the sensitivity of each IP by the direct comparison with reference dosimeters, such as ionization chambers. By this, small variation of each IP response can be effectively compensated. A change of IP sensitivity due to radiation damage is another important aspect to clarify [17]. Acknowledgements This work was partly supported by a grant-inaid for scientific research from the Ministry of Education, Science and Culture, Japan. References [1] C. Brusasco et al., Nucl. Instr. and Meth. A 389 (1997) 499. [2] R. Cirio, M. Donetti, F. Marchetto, C. Pedroni, Proc. 6th Workshop on Heavy-Charged Particles in Biology and Medicine, GSI-Report-97-09, 1997, p. G6. [3] Y. Hayakawa, Y. Amemiya, J. Tada, K. Hosono, T. Arimoto, Nucl. Instr. and Meth. A 378 (1996) 627. [4] L. Weissman, M. Hass, V. Popov, Nucl. Instr. and Meth. A 400 (1997) 409. [5] W.T. Chu, B.A. Ludewigt, T.R. Renner, Rev. Sci. Instrum. 64 (8) (1993) 2055. [6] V.V. Antonov-Romanovsky et al., Conf. Academy of Sciences of the USSR on the Peaceful Uses of Atomic Energy: Session of the Division of Physical and Mathematical Sciences, July 1 5, 1955 (English transl. by Consultants Bureau, Washington, U.S. Atomic Energy Commission, 1956, p. 259). [7] BAS Technical Information No.1, Fuji Film Co., Ltd., 1993. [8] C. Mori, A. Matsumura, Nucl. Instr. and Meth. A 312 (1992) 39. [9] T. Suzuki et al., J. Nucl. Sci. Technol. 34 (5) (1997) 461. [10] R. Yamadera et al., Radioisotopes 42 (1993) 676. [11] M. Takebe et al., Jpn. J. Appl. Phys. 34 (1995) 4197. [12] C. Mori et al., Nucl. Instr. and Meth. A 339 (1994) 278. [13] T. Buecherl, C. Rausch, H. Seggern, Nucl. Instr. and Meth. A 333 (1993) 502. [14] S. Nakamura, K. Inabe, Ionizing Radiation 23 (2) (1997) 53 (in Japanese). [15] T. Oikawa, D. Shindo, K. Hiraga, J. Electron Microsc. 43 (1994) 402. [16] O. Gei{, M. Kraemer, G. Kraft, Proc. 6th Workshop on Heavy-Charged Particles in Biology and Medicine, GSI- Report-97 09, 1997, p. G7. [17] H. Kobayashi et al., Nucl. Instr. and Meth. B 135 (1998) 229.