FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS

Similar documents
dc15xx CONTROL dc1500 AB220A5111 dc1550 FP220A5911 AB320A5211 FP320A5951 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS

XL-550. Liste de pièces Lista de Piezas Parts List

XL-580. Liste de pièces Lista de Piezas Parts List Copyright SVP Worldwide - All rights reserved

Liste de pièces Lista de Piezas Parts List

Data Sheet. Functional Safety Characteristic Safety Values for BE.. Brakes * _0715*

WEIGHT INDICATOR WIDRA W90

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

PHOENIX CONTACT - 04/2016. Features

Acceleration/Velocity/Displacement VIBRATION METER

EXPERIMENT Traffic Light Controller

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Electric amplifiers. RE 30044/02.12 Replaces: Type VT-VRPA X/V0/RTS-2STV. Component series 2X 1/8

DSC-244 DSC-244V INSTRUCTION MANUAL. No.03

X-LSM-E Series: Miniature motorized linear stages with built-in motor encoder and controllers

Moment and angular momentum

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

p tot Mechanics LD Physics Leaflets

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

Operating Instructions for Digital Manometer. Model: MAN-SD

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

MC200E PARTS LIST

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

VIBRATION METER. Instruction Manual.

Dielectric Analysis of Insulation Liquids

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

King Fahd University of Petroleum and Minerals College of Computer Science and Engineering Computer Engineering Department

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Facts and figures MULTILIFT SELECT 15

ECE20B Final Exam, 200 Point Exam Closed Book, Closed Notes, Calculators Not Allowed June 12th, Name

Optical Fiber Strain/Loss Analyzer AQ8602/8602B

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

X-LSM-SV1 Series: Low vacuum miniature motorized linear stages with built-in controllers

Lecture 13: Sequential Circuits, FSM

Chapter 2. Review of Digital Systems Design

CSE140: Components and Design Techniques for Digital Systems. Midterm Information. Instructor: Mohsen Imani. Sources: TSR, Katz, Boriello & Vahid

Lab #10: Design of Finite State Machines

[Agilent Technologies] [Electrochemistry Products] Quick Reference

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Synchronous Sequential Circuit Design

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Book Automation for sectional doors up to 12 m 2 and overhead doors up to 11 m 2

Tile Pro Drainage Plow Instruction Manual Wayne s Inc.

Newton s 2nd Law with demonstration track and Cobra4

EE201L Homework # One-Hot state assignment method of designing a state machine LRH = 000 BOTH LIGHTS OFF IDLE Q I Q R = 1 = 1000 Q L Q H

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

COE 202: Digital Logic Design Sequential Circuits Part 3. Dr. Ahmad Almulhem ahmadsm AT kfupm Phone: Office:

X-LRT-EC Series: High-load, closed-loop stages with built-in stepper motors, motor encoders, controllers, and dust covers

CTC 155 / 350 / 660 Dry-block calibrator

Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr Althengstett Tel

Calio-Therm NC Type Series Booklet

EE201l Homework # 6. Microprogrammed Control Unit Design

Standard specifications ZX165UFE02001

Lecture 13: Sequential Circuits, FSM

Sequential Circuit Analysis

Emergency lighting units EM Inverter

Series P02-23Sx80-HP. Series P02-23Sx80-HP 2. P02-23Sx80F-HP/220x P02-23Sx80F-HP/290x P02-23Sx80F-HP/20x60 5. P02-23Sx80F-HP/350x410 13

Software BioScout-Calibrator June 2013

Centripetal and centrifugal force

LOW PROFILE TRANSFERS

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

STUDENT EXPERIMENTS PHYSICS, CHEMISTRY & BIOLOGY

PC Control / Touch Control

Lecture 14: State Tables, Diagrams, Latches, and Flip Flop

Digital Torque Meter ADT-C Series OPERATION MANUAL

COE 202: Digital Logic Design Sequential Circuits Part 3. Dr. Ahmad Almulhem ahmadsm AT kfupm Phone: Office:

Uniformly accelerated motion with an accelerating mass with the demonstration track and timer 4 4

QUANTUM CONCEPT. Swimming User s Manual

Pushbutton Units and Indicator Lights

OEM Flow sensor for liquid media type 200

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) ELECTRICAL & ELECTRONICS ENGINEERING EXAMINATION SEMESTER /2017

P E R S O N A L L I G H T I N G S Y S T E M

CSE370: Introduction to Digital Design

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

Training Guide. Coastal Environmental Systems, Inc.

3B SCIENTIFIC PHYSICS

Lifting Column DMD. 12, 24 and 36 Vdc - load up to 6800 N. Performance Specifications. Standard Features and Benefits. General Specifications

VK2 volume flow controller Overview

ATT 310 USER MANUAL

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

HawkEye Pro. NEW and EXCLUSIVE Professional Diagnostic tool for the workshop or mobile technician. Fully unlocked for ALL Land Rover vehicles*

Necchi Supernova Automatica Sewing Machine Manual

Quantum Series Product Catalog

ISSP User Guide CY3207ISSP. Revision C

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

ph Probe ReallyEasyData com

Characteristic X-rays of molybdenum

Capacitor in the AC circuit with Cobra3

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

State Machines ELCTEC-131

Dewpoint Meter Data Sheet / Instructions

473-SHX Dew Point Mirror

W250: Compact photoelectric switch series for a broad range of applications

Digital Logic Design - Chapter 5

COMPUTER SCIENCE TRIPOS

Barograph 1.080x

Sequential Logic Circuits

MIDI FOOT CONTROLLER FCB

Cooling Water Flow Regulator

Transcription:

dcxx CONTROL ABS0 Instruction Manual - Adapter Cords No. 0 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD.

Important Notes The particulars used in various figures and tables, such as type, program number, speed, etc., serve as examples. They may differ from those in your display. For current versions of the Instructions for Use and Lists of Parameters, necessary for operating EFKA drives in accordance with regulations, please refer to the EFKA web site www.efka.net, page Downloads. On our web site you will also find the following supplementary instructions for this control: General instructions for use and programming Use with USB Memory Stick Use of the C00 compiler Adapter cords

- ABS0 - - CONTENTS Page Adapter Cords for Special Machines - Overview Adapter Cords Interconnection Diagrams

- - Adapter Cords Adapter Cords for Special Machines - Overview AISIN high-speed seamer ADXX, AD, 0 and overlock machine EK BROTHER model -, - 0 BROTHER lockstitch machine with 00 Ω select resistor, models xxx, Bxx, B, 0 Bxx, B (mode ) BROTHER chainstitch machine with 0 Ω select resistor, models FD-B, xx, xx, xx (mode ) BROTHER models B, B, B, B, B, B, B, B, B, B, B, B Connection of the position sensor incorporated in the handwheel BROTHER model B 0 DÜRKOPP ADLER models 0 and 0 GLOBAL model CB0- JUKI high-speed seamer with index - JUKI high-speed seamer with index - JUKI lockstitch machines Connection of the position sensor incorporated in the handwheel JUKI lockstitch machine models LU0- and LUN- JUKI lockstitch machine model DNU- JUKI lockstitch machine model DNU- Connection of the position sensor incorporated in the handwheel JUKI lockstitch machine models LU0, LU0 JUKI lockstitch machine model LU0N- 0 KANSAI machine model RX 0 0 PEGASUS models W00/UT, W00/UT/MS with or without stitch condensing PEGASUS backlatch machine PEGASUS chainstitch machine MHG-00 PFF models,, 00, 0 (without thread monitor) PFF models, RIMOLDI model F 0 SINGER models, U, UTT and UNION SPECIAL lockstitch machine model 00AMZ (in replacement of US0A) UNION SPECIAL model 00 with stitch lock UNION SPECIAL models 000 and 00 (in replacement of US0A) UNION SPECIAL models CS00 and FS00 0 YAMATO VC/VG series chainstitch machines + stitch lock YAMATO backlatch machine ABT YAMATO backlatch machine ABT, ABT 0 MITSUBISHI lockstitch machines Connection of the position sensor incorporated in the handwheel

- ABS0 - - Adapter Cords Interconnection Diagrams AISIN high-speed seamer ADXX, AD, 0 and overlock machine EK Setting the functional sequence Thread trimming mode Set parameter 0 = 0 Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = ST Nr. +V in SUB- D- 0 in +V +V +V +V M M NHT + +V Z +V M +V KL BROTHER model -, - 0 BROTHER models B, B, B, B, B, B, B, B, B, B, B, B Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = 0 Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = ST SUB- D- 0 in in +V +V +V +V M M M Nr. + + V + V Z + V + V NHT 0 0 KL

- - BROTHER chainstitch machine with 0 Ω select resistor, models FD-B, xx, xx, xx (mode ) BROTHER models B, B, B, B, B, B, B, B, B, B, B, B Connection of the position sensor incorporated in the handwheel Adapter Cords Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = Input in Set parameter = Input in Set parameter = ST 0 +V in in in in Nr. LSP ZSTV +V ENTK STVU SUB- D- +V +V +V +V M M +V STV +V +V 0 0 LSP M +V KL

- ABS0 - - BROTHER Model B 0 Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = ST +V R-N-EXT in Nr.0 +V R-N-EXT in U SUB- D- 0 in in in +V +V +V NH HP DB L +V STL M 0 M0 M +V M +V FSPL Z 0 0 M +V +V STL MST KL in = Input speed limitation n (flip-flop ) output ST/ is active according to setting of parameter (DB) in = Input needle up (NH) in = Input high lift for walking foot with speed limitation n0 (flip-flop ) (HP) in= Input stitch regulator suppression / stitch regulator recall (U) in = Input intermediate backtack / intermediate stitch condensing (Z) **) Attention: Note the mark on pin of the connector strips!

- - Adapter Cords DÜRKOPP ADLER models 0 and 0 Setting the functional sequence Thread trimming mode Set parameter 0 = 0 Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = Input in Set parameter = Input in Set parameter = ST Nr. in SUB- D- 0 in in in +V +V 0 POS M M POS +V + 0 NHT U Z EST 0 M KLa GLOBAL model CB0- Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = ST Nr. + V in 0 +V SUB- D- +V M + V 0 LSP 0 KL0

- ABS0 - - JUKI high-speed seamer with index - Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter = Nr. Z ST 0 in +V +V +V SUB- D- +V +V +V M +V + 0 0 +V M KLb JUKI high-speed seamer with index - Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter = ST Nr. + in FZ Z SUB- D- +V 0 +V +V +V M M +V +V 0 +V +V 0 +V +V M KL **) Front view (component side) of the Molex Minifit plugs.

- 0 - Adapter Cords JUKI lockstitch machine models LU0- and LUN- Connection of the position sensor incorporated in the handwheel (LU0-) (LUN-) Setting the functional sequence Thread trimming mode Set parameter 0 = 0 0 Setting the functions of the keys Input in Set parameter 0 = 0 (Automatic setting) Input in Set parameter = 0 Input in Set parameter = Input in Set parameter = Input in Set parameter = in = Input high lift for walking foot with speed limitation n0 (operational mode not stored) for knee switch in = Input speed limitation bit 0 (S) in = Input speed limitation bit (S) in = Input intermediate backtack in = Input high lift for walking foot with speed limitation n0 (operational mode not stored) for additional pushbutton on the machine head **) Front view (component side) of the Molex Minifit plugs.

- ABS0 - - JUKI lockstitch machine model DNU- Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = 0 Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = ST 0 0 in in in in in in in in +V Nr. Z NHT U HP in LHP HP out +V +V +V FF in FFout 0 0 SUB- D- 0 +V +V M M0 M +V FSPL +V S S M M HP in KL0 in = Input high lift for walking foot with speed limitation n0 (operational mode not stored) for knee switch in = Input needle up/down in = Input speed limitation bit 0 (S) in = Input speed limitation bit (S) in= Input stitch regulator suppression / stitch regulator recall in = Input intermediate backtack in = Input high lift for walking foot with speed limitation n0 (operational mode not stored) for additional pushbutton on the machine head in = Input speed limitation n (operational mode stored)

- - Adapter Cords JUKI lockstitch machine models LU0, LU0 0 Connection of the position sensor incorporated in the handwheel Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input i0 Set parameter = ST 0 R-N-EXT in in in in Nr. 0 Z NHT U HP HP HP in in 0 SUB-D- i0 +V +V +V +V +V +V +V 0 LD +V M +V +V FSPL +V 0 M +V HP M +V W W +V,k/0,W BL +V LD U ML +V KLa in = Input needle up/down (NHT) in = Input Juki bobbin thread monitor (W) in = Input high lift for walking foot with speed limitation n0 (HP) (flip-flop ) in = Input intermediate backtack / intermediate stitch condensing (Z) in= Input stitch regulator suppression / stitch regulator recall (U) in = Input Juki bobbin thread monitor (W) i0 = Input reset bobbin thread monitor (U)

- ABS0 - - KANSAI machine model RX 0 0 Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = ST +V Nr. 0 +V LSP 0 in +V SUB- D- +V +V +V +V M +V +V ML M M +V KL PFF models,, 00, 0 (without thread monitor) Setting the functional sequence Thread trimming mode Set parameter 0 = 0 Setting the functions of the keys Input in Set parameter = Input in Set parameter = Nr. +V ST 0 in in +V EX +V SUB- D- +V +V +V +V +V M M M +V +V M ML +V Z +V Z KL

- - Adapter Cords PFF Kl., Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input in Set parameter = Input i0 Set parameter = ST SUB- D- 0 0 in in in in in in in in i0 +V M Nr. H NHT HP L-NHT L-HP U STL 0 STOP L-U L-STL L-STOP +V SUB- D- 0 M M +V M M M0 M M M +V +V +V +V FSPL 0 +V M HP 0 STL SUB- D- M ML 0 DB DB DBx KL +V ML in = Input needle up in = Input intermediate backtack in = Input needle moves from position to position in = Input speed limitation n with pedal (DB = speed limitation ) in = Input flip-flop for speed limitation n in = Input speed limitation n (DB = speed limitation ) in = Input high lift for walking foot with speed limitation n0 (operational mode stored) in= Input stitch regulator suppression / stitch regulator recall i0 = Input speed limitation with external potentiometer

- ABS0 - - PEGASUS models W00/UT, W00/UT/MS with or without stitch condensing Attention! When using this adapter cord on a Pegasus machine, the -core cable no. - must be removed from the machine! Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = ST SUB- D- 0 +V in +V +V +V +V M M Nr. +V +V +V +V LSP +V +V M STV +V KL0 PEGASUS backlatch machine Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = 0 ST 0 in Nr. Ped = Ped = - N-AUTO in SUB- D- LSP M M Ped = - KL

- - Adapter Cords PEGASUS chainstitch machine MHG-00 Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = input in Set parameter = Input in Set parameter = Input in Set parameter = Nr. in ST +V 0 in in in SEN +V SUB- D- in +V +V +V +V +V +V +V M M +V M M +V LSP M +V +V M M +V +V M +V M in KL

- ABS0 - - RIMOLDI model F 0 Setting the functional sequence Thread trimming mode Set parameter 0 = ST Nr. 0 0 +V +V +V ML SUB- D- M M M O U +V M KL SINGER models, U, UTT and Setting the functional sequence Thread trimming mode Set parameter 0 = (Singer model UTT) Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = ST 0 in in Nr. +V /FSPL NHT Z +V SUB- D- +V +V +V +V / M M +V +V M KL

- - Adapter Cords UNION SPECIAL model CS00 and FS00 0 Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = Nr. 0 ST in +V POS LSP SUB- D- 0 0 in +V +V POS +V ML +V M M +V -V M +V +V LSP 0 M -R 0 KL0 in = Input machine run blockage for thread trimming control proximity switch in = Input machine run blockage for thread monitor UNION SPECIAL lockstitch machine model 00AMZ (in replacement of US0A) Setting the functional sequence Thread trimming mode Set parameter 0 = 0 ST Nr. ML +V SUB- D- 0 +V +V M M M -V -R 0 0 KL

- ABS0 - - UNION SPECIAL model 00 with stitch lock Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter = Input in Set parameter = ST 0 Nr. 0 in in +V +V LSP NK 0 SUB- D- +V +V +V +V 0 0 POS +V M M M +V +V STV M +V POS STOP +V ML KL0

- 0 - Adapter Cords UNION SPECIAL model 000 and 00 (in replacement of US0A) Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = Input in Set parameter = Input in Set parameter = Input in Set parameter = ST in Nr. AT-S EX AT-S in EX 0 in in SUB- D- +V +V +V +V POS LSP 0 POS +V POS GEN +V GEN ML M M POS POS M +V +V ML -V +V -V +V LSP 0 -R 0 KL in = Input machine run blockage for thread trimming control proximity switch in = Input machine run blockage for thread monitor in = Input unlocking the chain corresponds to function flatseamer (AT-S) in = Input sewing foot lift with pedal in pos. 0 (neutral)

- ABS0 - - YAMATO VC/VG series chainstitch machines + stitch lock Setting the functional sequence Thread trimming mode Set parameter 0 = / Setting the functions of the keys Input in Set parameter 0 = ST in Nr. +V SUB- D- 0 +V +V +V M LSP +V M +V +V STV +V M ML KL

- - Adapter Cords YAMATO backlatch machine ABT Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = ST 0 +V in in Nr. Ped = Ped = - N-AUTO SUB- D- M POSQ LSP +V +V M R POSQ KL YAMATO backlatch machine ABT, ABT 0 Setting the functional sequence Thread trimming mode Set parameter 0 = Setting the functions of the keys Input in Set parameter 0 = (Automatic setting) input in Set parameter = input in Set parameter = ST 0 +V in in Nr. 0 Ped = Ped = - N-AUTO SUB- D- in POSQ M LSP +V M N-AUTO POSQ KL

- ABS0 - - For your notes:

FRANKL & KIRCHNER GMBH & CO KG SCHEFFELSTRASSE SCHWETZINGEN GERMANY PHONE: +-0-00 X: +-0-0 E-MAIL: info@efka.net http://www.efka.net OF AMERICA INC. NORTHCREST ROAD SUITE 0 ATLANTA GEORGIA 00 PHONE: + (0) -00 X: + (0) - E-MAIL: efkaus@bellsouth.net ELECTRONIC MOTORS SINGAPORE PTE. LTD., AYER RAJAH CRESCENT 0-0 SINGAPORE 0 PHONE: +- X: +-0 E-MAIL: efkaems@efka.net ()-00 (0 EN)