Evidence of Performance Thermal transmittance

Similar documents
Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Test of resistance to wind load under dynamic wind load. Roller shutter with built-in box, inspection from inside and foamed aluminium laths

WITH LOW EMISSIVITY GLASS

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

Certificate Sound reduction of building elements

Winter Night. Thermos 6mm Outdoors # #

Calculating the heat transfer coefficient of frame profiles with internal cavities

Collector test according to EN ,2:2002

Report TAG3-UA-1212-E07 Testing of the transmission and the g-value of a polycarbonate multiwall panel AKYVER 16/7 IR Control Grey

Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

Content. Thermal insulation

Report of Performance Test according to EN for a Glazed Solar Collector

HIGHLY INSULATING AEROGEL GLAZING

Warm surfaces warm edges Insulated glass with thermally improved edge seal

Heat Transfer: A Practical Approach - Yunus A Cengel Assignment 11 Fall 2003 Tuesday, November 18, 2003 Chapter 11, Problem 49

Technical Data Sheet - Planibel

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Declarations of equivalence of Verosol sun screens. SilverScreen and EnviroScreen

Glazing selection for solar design

Determination of thermal transmittance of window (test title)

Report of Performance Test according to EN for a Glazed Solar Collector

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

Approaching energy-neutral window glazing

BRE Client Report. Calculation of summertime solar shading performance for MicroLouvre. Prepared for: Smartlouvre. BRE Watford, Herts WD25 9XX

LOW E SATINÉ 5500 LOW E

Collector test according to EN ,2 : 2006

SIMULATION TEST REPORT NCTL E0A0

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

SIMULATED THERMAL PERFORMANCE OF TRIPLE VACUUM GLAZING. Yueping Fang, Trevor J. Hyde, Neil Hewitt

ISO INTERNATIONAL STANDARD

Evaluation of Program Calculation Procedures according to Standards EN 673 and EN 410

WINDOW SIMULATION REPORT

SCREEN LOW E SATINÉ 5500 LOW E

SCREEN LOW E SATINÉ 5500 LOW E

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

Collector test according to EN ,2:2006

1D and 3D Simulation. C. Hochenauer

Div. 1 Div. 2 Div. 3 Div.4 8:30 am 9:30 pm 12:30 pm 3:30 pm Han Xu Ruan Pan

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

THE INFLUENCE OF GLAZING TYPE, FRAME PROFILES SHAPE AND SIZE OF THE WINODOW OF THE FINAL VALUE OF WINDOW THERMAL TRANSMITTANCE U

THERMAL SIMULATION REPORT. TCL2013-Origin-01 Prepared For:

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Design strategy for Low e windows with effective insulation

LOW E SATINÉ 5500 LOW E

Available online at ScienceDirect. Energy Procedia 54 (2014 )

Performance Assessment of PV/T Air Collector by Using CFD

KEYWORDS Glazing; Window; Low E; Teflon; U-value; Shading Coefficient INTRODUCTION

Cool Roofs Standards & the ECRC Product Rating Program

TIR100-2 Measurement of Thermal Emissivity

Transparent building elements. Translucent building elements. Environmental Product Declaration (EPD) Short version Declaration Code: EPD-RLE-33.

Shielding Effectiveness of Modern Energy Saving Windows

The energy performance of an airflow window

Natté P CLARITY & COMFORT POLYESTER OF = 1-10% COPACO NATTÉ P

Description of Benchmark Cases for Window and Shading Performance Calculation

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Collector test according to EN ,2:2006

Blockout Déco N203 COLLECTION BLOCK SUNLIGHT BLOCKOUT OF = 0% COPACO BLOCKOUT DÉCO N203

Natté COLLECTION CLARITY & COMFORT GLASSFIBRE OF = 1-10% COPACO NATTÉ

CAE 331/513 Building Science Fall 2016

Solar Flat Plate Thermal Collector

CFD-SIMULATIONS OF TRANSPARENT COATED AND GAS-FILLED FACADE PANELS

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

DYNAMIC INSULATION APPLIED TO THE RESIDENTIAL BUILDING (PART 2) Numerical Evaluation of Thermal Insulation Effect on Air Supply Window System

Cool Roofs Standards & the ECRC Product Rating Program

INDUSTRIA ESPAÑOLA PARA EL DESARROLLO E INVESTIGACIÓN 2100, S.A. (IEdiSA) PATRICIA SILVA

Thermal Systems Design MARYLAND. Fundamentals of heat transfer Radiative equilibrium Surface properties Non-ideal effects

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

Sound insulation of planted noise barriers

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

ScienceDirect. Development of an insulated glass solar thermal collector

CAE 463/524 Building Enclosure Design Fall 2012

Serge 600 COLLECTION REFLECTS SUNLIGHT OUTDOORS GLASSFIBRE OF = 5%

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

reflect sunlight outdoors Serge 600 ARCHITECTS SELECTION GLASSFIBRE OF = 5%

Leybold Optics Low-E series

c. The Grashof number is the ratio of buoyant forces to viscous forces acting on a fluid.

D i s t a n ce Sensor DS 60

TREES Training for Renovated Energy Efficient Social housing

AC-829A. Issued on Apr. 15 th 2013 (Version 1.0)

TECHNICAL COMMITTEE of the EU Cool Roofs Council

SIMULATION OF FRAME CAVITY HEAT TRANSFER USING BISCO v10w

TFI Report Sound Absorption Impact Sound Insulation

Baker House Dining Room: Thermal Balance Report. + Q c. + Q v. + Q s. + Q e. + Q heating. + Q appliances. =Q appliances,21h Q appliances, x H

UNIT FOUR SOLAR COLLECTORS

Experimental Performance and Numerical Simulation of Double Glass Wall Thana Ananacha

visual comfort Natté 390 GLASSFIBRE OF = 3%

Renolit stretch ceilings

Mathematical Modelling of Ceramic Block Heat Transfer Properties

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Appendix 5.A11: Derivation of solar gain factors

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

Fabric HUSH Manufacturer Gabriel A/S

Transcription:

Evidence of Performance Thermal transmittance Test Report 10-001988-PR02 (PB-H01-06-en-01) Client Mályi-Glass Kft. Pesti ut 7 3434 Mályi Hungary Product Insulating glass unit System designation Variants of the following construction, see type sheet Construction filling IR-Coating Guardian ClimaGuard Solar coated surface: see type sheet, ε n =0.01* *source: as specified by the manufacturer Coating Special features -/- Thermal transmittance Basis EN 673 : 1997-11 +A1 : 2000-10 + A2 : 2002-12 Glass in building - Determination of thermal transmittance (U value) - Calculation method Test report 10-000228-H01-06-en-01 dated 08 July 2010 Instructions for use This test report serves to demonstrate the thermal transmittance U g. Validity The data and results given relate solely to the described configurations. Determination of thermal transmittance does not allow any statement to be made on further characteristics of the present structure regarding performance and quality. U g = 0.5 1.3 W/(m 2 K)* * specific value depends on construction (see type sheet) Notes on publication The ift Guidance Sheet "Conditions and Guidance for the Use of ift Test Documents" applies. The cover sheet can be used as an abstract only including the type sheet. ift Rosenheim 10 March 2011 Michael Rossa, Dipl. Phys. Head of Testing Department Building Material & Semifinished Products Konrad Huber, Dipl.-Ing. (FH) Deputy Head of Testing Department Building Physics Contents The report contains a total of 5 pages Type sheet 1 Object 2 Procedure 3 Detailed results 07-04 / 387

Page 2 of 5 Type sheet for insulating glass unit Type of pane Characteristic values used for calculation Construction in mm filling rate in % Type of gas/ proportions U g E** ε n * U g-value calculated according to DIN EN 673 T = 15 K in W/(m 2 K) 1 4/16/4 100 Air 2 0.01 1.3 2 4/16/4 90 Argon 2 0.01 1.0 3 4/18/4 90 Argon 2 0.01 1.1 4 4/18/4 93 Argon 2 0.01 1.0 5 4/14/4/14/4 90 Argon 2+5 0.01 0.6 6 4/16/4/16/4 90 Argon 2+5 0.01 0.5 ε n * normal emissivity; source: as specified by the manufacturer E** coated surface

Page 3 of 5 1 Object 1.1 Description of test specimen (All dimensions in mm) Product Insulating glass unit System designation Construction in mm Coating Type / manufacturer Guardian ClimaGuard Solar / Guardian Hungary Ltd. Coated surface Normal emissivity ε n 0.01 Source As specified by the manufacturer filling in cavity As specified by the manufacturer Type of gas filling rate in % Item designations/numbers as well as material specifications were given by the manufacturer. (Additional data provided by the client are marked with * ) ). 1.2 Representation of insulating glass construction The illustration was produced by the ift as a schematic representation of the cross section. surface 1 2 3 4 surface 1 2 3 4 air / Argon Argon Figure 1 4 16 4 Representation of Figure 2 4 18 4 Representation of

Page 4 of 5 surface 1 2 3 4 5 6 Argon 4 14/16 4 14/16 4 Figure 3 Representation 2 Procedure 2.1 Method/s 2.1.1 Calculation of thermal transmittance Basis EN 673: 1997-11 +A1: 2000-10 +A2: 2002-12 Boundary conditions Glass in building - Determination of thermal transmittance (U value) - Calculation method as per standard specifications Slope of glazing vertical ε n = 0.89 normal emissivity of the room-sided surface ε = 0.837 corrected emissivity of the room-sided surface h i = 8 W/(m² K) heat transfer coefficient h e = 23 W/(m² K) heat transfer coefficient Deviation 2.2 Testing Date/period 08 July 2010 Testing personnel There have been no deviations from the test methods and/or test conditions Christine Lux, Dipl.-Phys.

Page 5 of 5 3 Detailed results Table 1 Calculated thermal transmittances U g of insulating glass units listed below Type of pane Characteristic values used for calculation Construction in mm filling rate in % Type of gas/ proportions U g E** ε n * U g-value calculated according to DIN EN 673 T = 15 K in W/(m 2 K) 1 4/16/4 100 Air 2 0.01 1.3 2 4/16/4 90 Argon 2 0.01 1.0 3 4/18/4 90 Argon 2 0.01 1.1 4 4/18/4 93 Argon 2 0.01 1.0 5 4/14/4/14/4 90 Argon 2+5 0.01 0.6 6 4/16/4/16/4 90 Argon 2+5 0.01 0.5 ε n * normal emissivity; source: as specified by the manufacturer E** coated surface ift Rosenheim 10 March 2011