THE PRESSURE-TIME MEASUREMENTS PROJECT AT LTU AND NTNU

Similar documents
UNCERTAINTIES FOR PRESSURE-TIME EFFICIENCY MEASUREMENTS

Implementing unsteady friction in Pressure Time measurements

Transient wall shear stress measurements at a high Reynolds number

Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve

Experiment (4): Flow measurement

Experimental investigation on a high head model Francis turbine during load rejection

Experimental Investigation of a High Head Model Francis Turbine During Steady-State Operation at Off-Design Conditions

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Head loss coefficient through sharp-edged orifices

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

LEAKLESS COOLING SYSTEM V.2 PRESSURE DROP CALCULATIONS AND ASSUMPTIONS

International Journal of Civil Engineering and Geo-Environment. Investigation of Parameters Affecting Discrete Vapour Cavity Model

Feasibility study of the cascading mass ow rate evaluation as a new variant of Gibson's method

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

Investigation of Flow Profile in Open Channels using CFD

Efficient runner safety assessment during early design phase and root cause analysis

Installation effects on an ultrasonic flow meter with implications for self diagnostics

Evaluation of pump characteristic from measurement of fast deceleration

The influence of disc friction losses and labyrinth losses on efficiency of high head Francis turbine

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ME 316: Thermofluids Laboratory

Experimental Study on Port to Channel Flow Distribution of Plate Heat Exchangers

CHAPTER THREE FLUID MECHANICS

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Comparison between Numerical and Experimental for UVP Measurement in Double Bent Pipe with Out-of-Plane Angle

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

ME332 FLUID MECHANICS LABORATORY (PART II)

Experiment No.4: Flow through Venturi meter. Background and Theory

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

Applied Fluid Mechanics

Applied Fluid Mechanics

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

INTERNATIONAL STANDARD

Lecture23. Flowmeter Design.

UNSTABLE OPERATION OF FRANCIS PUMP-TURBINE AT RUNAWAY: RIGID AND ELASTIC WATER COLUMN OSCILLATION MODES

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Performance Prediction of the Francis-99 Hydroturbine with Comparison to Experiment. Chad Custer, PhD Yuvraj Dewan Artem Ivashchenko

Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

Flowmeter Discharge Coefficient Estimation

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

State of the art hydraulic turbine model test

Dynamic Behavior of a 2 Variable Speed Pump- Turbine Power Plant

Hydro-acoustic resonance behavior in presence of a precessing vortex rope: observation of a lock-in phenomenon at part load Francis turbine operation

PERFORMANCE OF A CENTRAL-TYPE JET PUMP II- EXPERIMENTAL STUDY ON WATER FLOW

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Q1 Give answers to all of the following questions (5 marks each):

Lesson 37 Transmission Of Air In Air Conditioning Ducts

An overview of the Hydraulics of Water Distribution Networks

Hydraulics and hydrology

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

Application of an ultrasonic velocity profile monitor in a hydraulic laboratory

Lesson 6 Review of fundamentals: Fluid flow

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Piping Systems and Flow Analysis (Chapter 3)

Numerical and Experimental Study on the Effect of Guide Vane Insertion on the Flow Characteristics in a 90º Rectangular Elbow

Bounding the Uncertainties of the Meter Factors for LEFM CheckPlus Flow Elements in Feedwater Flow Measurements

STRUCTURAL RESPONSE OF A PIPELINE APPARATUS TO PULSATING FLOW AT RESONANCE AND NON- RESONANCE CONDITIONS

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

ANALYSIS OF NATURAL FREQUENCIES OF DISC-LIKE STRUCTURES IN WATER ENVIRONMENT BY COUPLED FLUID-STRUCTURE-INTERACTION SIMULATION

The Fluid Flow in the T-Junction. The Comparison of the Numerical Modeling and Piv Measurement

To investigate the performance of the Pelton Wheel turbine with different range of flow rates and rotational speeds.

Reynolds, an engineering professor in early 1880 demonstrated two different types of flow through an experiment:

Lecture Note for Open Channel Hydraulics

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts. Flow in Pipes and Ducts. Flow in Pipes and Ducts (cont d)

Lecture 4. Lab this week: Cartridge valves Flow divider Properties of Hydraulic Fluids. Lab 8 Sequencing circuit Lab 9 Flow divider

FURTHER INVESTIGATION OF PARAMETERS AFFECTING WATER HAMMER WAVE ATTENUATION, SHAPE AND TIMING PART 2: CASE STUDIES

AN INDIRECT MEASUREMENT METHOD OF TRANSIENT PRESSURE AND FLOW RATE IN A PIPE USING STEADY STATE KALMAN FILTER

Chapter 8: Flow in Pipes

Applied Fluid Mechanics

Effect of Geometric Configuration on Performance of Uniflow Cyclone

Hydroelectric Design

An Essential Requirement in CV Based Industrial Appliances.

GUIDE VANES EMBEDDED VISUALIZATION TECHNIQUE FOR INVESTIGATING FRANCIS RUNNER INTER-BLADE VORTICES AT DEEP PART LOAD OPERATION

Determination of Optimum Pressure Loss Coefficient and Flow Distribution at Unsymmetrical Pipe Trifurcation Using Experimental and Numerical Technique

2 Internal Fluid Flow

1-Reynold s Experiment

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Chapter 7 The Energy Equation

Sudden Expansion Exercise

Numerical Simulation of a Complete Francis Turbine including unsteady rotor/stator interactions

ME 305 Fluid Mechanics I. Chapter 8 Viscous Flow in Pipes and Ducts

EXPERIMENT NO: F5. Losses in Piping Systems

DESIGN AND CONSTRUCTION OF A WATER TUNNEL. Stephen C. Ko

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

ANALYSIS OF THE GAMM FRANCIS TURBINE DISTRIBUTOR 3D FLOW FOR THE WHOLE OPERATING RANGE AND OPTIMIZATION OF THE GUIDE VANE AXIS LOCATION

Sensitivity Estimation of Permanent Magnet Flowmeter

Viscous Flow in Ducts

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

ME332 FLUID MECHANICS LABORATORY (PART I)

Laboratory work No 2: Calibration of Orifice Flow Meter

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

CIVE HYDRAULIC ENGINEERING PART II Pierre Julien Colorado State University

Visualization of flow pattern over or around immersed objects in open channel flow.

EXPERIMENT AND NUMERICAL STUDY OF SUPERCRITICAL CARBON DIOXIDE FLOW THROUGH LABYRINTH SEALS

Transcription:

THE PRESSURE-TIME MEASUREMENTS PROJECT AT LTU AND NTNU ABSTRACT Pontus P. Jonsson, Luleå University of Technology Jørgen Ramdal, Norwegian University of Science and Technology Michel J. Cervantes, Luleå University of Technology Ole G. Dahlhaug, Norwegian University of Science and Technology Torbjørn K. Nielsen Norwegian University of Science and Technology The Norwegian University of Science and Technology (NTNU) and Luleå University of Technology (LTU) have during the last two years collaborated in the development of the pressure-time method for hydropower application, also known as Gibson method. The research is motivated by the need of a fast, reliable and cost effective method for low head hydraulic efficiency measurements, i.e., outside the IEC 41 standard. The collaboration has involved the construction of a test rig at NTNU specifically designed to study the pressure-time method. The laboratory test rig allows high accuracy flow measurements and evaluation of different solutions before field tests. Furthermore, the high accuracy and repeatability of such measurements are used for the validation of numerical codes on the matter. Field tests at Anundsjoe power plant in Sweden have been performed. Simultaneous measurements within and outside the IEC 41 standard were made for comparison. The laboratory results show that the calculated mean flow rate does not differ much if the distance between the measuring cross-sections is shorter than specified in the standard. However, the uncertainty and spread become larger as the distance between the measurement cross-sections decreases. A slightly velocity dependence is found where the flow gets gradually over estimated with decreasing velocity. In the field test, the difference between the measured discharges (according to and outside the standard) is less than 1% and random. For the case with bends within the control volume, both the laboratory and field tests show that this will cause an underestimation of the flow. A future aim would be to develop a systematic compensation for this underestimation based on pipe diameter, bend angle and bend radius. INTRODUCTION Hydro power is a rather old and clean energy source. Nowadays many plants are in need of refurbishment. Also new power plants are under construction. After construction or refurbishment of hydro power plants efficiency measurements are desirable, usually for guarantee reasons. There are well known methods for this purpose, e.g., thermo dynamic, current meter, pressure-time and ultra sonic. Most of these methods have high accuracy when used at favorable conditions. However, in the case of low head power plants there are problems with most methods due to, e.g., short and non-uniform water passages. This makes guarantee tests difficult to perform and in some cases it is even skipped. The pressure-time method, also known as Gibson s method, was developed in the early 20 th century, see Gibson [1]. It has, for a long time, been commercially used for site efficiency test due to its accuracy and, often, easy installation. Throughout the years there have been developments which have founded the specifications stated in an International Standard (IEC 41 [2]). The pressure-time method measures the discharge through pipes and conducts and is de facto an indirect method for site efficiency tests. The method is, roughly described, based on Newton s second law and uses the relation of the retarded mass of water and the corresponding pressure force that occurs during a rapid deceleration of the flow. By 55

measuring the differential pressure force between two cross-sections and integrate over time it is possible to calculate the initial velocity from which the flow was retarded from, see equation 1. Q = A ρl t ( P + ζ ) dt + q 0 [m 3 /s] (1) The main, and well known, challenges of the method are according to the IEC 41 standard the limitation of the measuring length (the measuring length, L, must be over 10 m) and low initial velocities in combination of short measuring lengths (the velocity times the measuring length, UL, must exceed 50 m 2 /s). This paper describes and presents results from a joint project between the Norwegian University of Science and Technology and Luleå University of Technology aiming to extend the pressure-time method to power plants where water passages (straight and homogenous pipes) available for measurements are too short to fulfill the criterions stated in IEC 41. The project includes: Numerical analysis o Simulation of valve closure with corresponding pressure-time calculation Laboratory experiments o Measurements on straight pipes with variable L and UL o o Sections enclosed with bends Effects of sensor type Field tests to validate the laboratory results LABORATORY EXPERIMENTS AND NUMERICAL SIMULATIONS Experimental setup The laboratory work is performed at the Water Power Laboratory at NTNU. The test rig used for this purpose consists of an open gravity driven pipe system with a maximum discharge of about 0.410 m 3 /s, see Figure 3. The available head for the system is 9.75 m (from the head level down to the measuring section). The test section consists of a 26.67 m stainless steel pipe with an internal diameter of 0.3 m. For the experiments with straight pipes, measurement sections are made at 11 positions along the test section. The first section is located 3.7 m upstream the valve and the 10 remaining sections at every meter further upstream. At each measuring section 4 pressure taps are mounted with 90 degree spacing around the circumference. A reference measuring section is positioned 20.7 m upstream the valve. When a 90 degree double bend or a 45 degree double bend are inserted in the system the total length of the test section increases with 2.11 or 2.644 m, respectively. The downstream elbow is located 9.2 m upstream the gate valve, see Figure 3. A hydraulic driven gate valve is used for the closing sequence. The closing time can be adjusted down to 2.5 s but it is kept around 4-5 s due to safety reasons. Repeatability of the closing time and effect of different times can be seen in Jonsson et al [3]. The initial discharge is adjusted with a throttle downstream the gate valve. A magnetic flow meter from Krohne (IFS 4000) is used as reference during all tests. It is calibrated with a weighing-time system and has an over all accuracy of 0.3%. The tests are performed both with absolute and differential pressure sensors. The differential sensors used were Honeywell FP2000/FDW sensors. They have a range of ±0.5 bar and an accuracy of 0.25%. Totally 4 sensors are used; one at each position around the circumference. They are connected with plastic tubing which has an internal diameter of 6 mm and a length of 5 m. The absolute sensors used were Druck PTX 1830. They have a range from 0 to 5 bars and an accuracy of 0.1%. Totally 8 sensors are used; 4 at each measuring section, mounted directly on the pressure taps. 56

A 16 bit data acquisition system (Ni-6221) from National Instruments was used in the measurements. The sampling frequency was set to 2 khz and the logging was performed without filtering. Upper reservoir level Overfall Flowmeter Manual inlet valve 400 400 300 860 1st bends position Gatevalve for Gibson method experiments Overfall outlet 45 400 Outlet Flow calibration tank 300 400 2016,1 Figure 3: Schematic of the test rig at NTNU. MEASUREMENTS The measurements were performed at 4 different lengths; L=3, 6, 9 and 17 m for straight pipes and 4, 6, 9 and 20 m for the setup with bends. 3 discharges were chosen for the survey; Q 1 0.4, Q 2 0.3 and Q 3 0.17 m 3 /s. With these measuring lengths and flow rates the UL relation can be varied from 10 to 100 m 2 /s. This variation allows measurements inside and outside the criterions stated in the IEC 41 standard. For the cases with bends the laboratory measurements were performed in 4 steps. First reference measurements with a straight pipe were performed. Thereafter tests with the two different sets of s-shaped pipes and at last reference measurements with a straight pipe were repeated. Double bends was chosen to amplify possible effects of the bend. There is a discussion whether the double bend will double or cancel out the effects of the bend, but until otherwise can be proved it is assumed that it will double the effects. Furthermore, it was most suitable due to installation reasons. For more detail regarding the setup and measurement procedure, see Jonsson et al [3], Ramdal et al [4] and Ramdal et al [5]. NUMERICAL METHOD Numerical simulations are made for comparison with laboratory experiments. A 1-dimensional Godunov type scheme called MUSCL-Hancock is used for the simulations, see Toro et al [6]. The transient friction is modeled with Brunone s model with Viskovsky formulation, see Bergant et al [7]. The test rig, from the head tank down to the test section, consists of bends, contractions and different pipe dimensions. Thus, the numerical model becomes complex if all parts are modeled. Therefore, the geometry is simplified with a straight pipe with an internal diameter of 0.3 m and a length of 40 m (approximately the length from the gate valve up to the head water level). The simulated pressures are thereafter used in pressure-time calculations, i.e., in the same way as in the experiments. See Jonsson et al [8] for more details regarding the numerical procedure. 57

FIELD TESTS The field measurements were performed at the Anundsjoe power plant in Sweden. It has one Francis unit producing 5 MW at full load with a discharge of 10 m 3 /s. The nominal head is 58.5 m and the water is delivered to the turbine through a vertical penstock. The penstock consists of a straight tube about 50 m long with an internal diameter of 2.2 m. Major part of the tube is in an accessible shaft allowing installation of pressure-time equipment. Its length allows also measurements according to the IEC 41 standard as well as outside the criterions. Figure 4 shows an overview of the power plant geometry with the instruments. The measurements were performed with the same sensors as the laboratory experiments but since only 6 sensors were available for measurements, 3 sensors were used for each measuring length. Hence, the logging was simultaneously performed at both lengths. Pressure taps were mounted with 120 degrees around the circumference of the penstock. The sensors were connected to the taps with nylon hoses; internal diameter of 8 mm. Two lengths were chosen; 7 and 30 m. The 30 m length was used for the efficiency test and as reference in the present survey. It satisfies the IEC 41 standard from around 65% load (UL>50). Since it was an efficiency test, the measurements were performed over the whole operational range and thus, many operational points were tested with the drawback of few repetitions. It had been preferable with fewer operational points with gain of more repetitions. Totally 19 tests were completed; from part load up to full load. The results are presented in a similar way as the laboratory experiments but with the measurements at 30 m used as reference, see following equation: e= Q Q / Q + q [-] (2) ( ) ( ) 7 30 30 2x PT 2200 mm 3x DPT 7 m 3x DPT 30 m 2x PT Concrete 13,98 m R=3500 mm 2x PT 2081,4 mm 2050 mm 800 mm Figure 4: Anundsjoe power plant overview. (PT are absolute pressure transducers, DPT are differential pressure transducers) 58

Measurements with the bend were performed simultaneously with measurements in the pipe for L=30 m; the later is used as reference for analysis. Absolute pressure transducers were used instead of differential pressure transducers due to installation reasons. The transducers were mounted at the upper measurement cross-section and after the bend. The distance between the straight pipe measurement crosssection and the measurement cross-section after the bend is 47.938 m. Transducers were also placed at the down stream cross section used in the 30 m distance measurements. The pressure sensors used were Druck PTX 610 and Druck PTX 1830. The pressure sensors downstream the bend did not have an optimal position since the spiral casing is close to the bend. This means the pressure taps had to be placed just downstream the bend; hence, it gives velocity and pressure distributions which ads uncertainty to the measurement. They also had to be placed 0.8 m into the converging pipe, which make need for compensation in the flow calculation equation in order to compensate for the small pressure difference the velocity difference cause. The fact that the bottom half of the pipe in front of the spiral casing is cast-in in concrete also gave limitation. The pressure transducers could only be mounted on the top half, giving uncertainty of the mean pressure. Further only two pressure transducers were installed. They were installed as close to the vertical middle of the pipe as far as the installation of the pressure taps allowed it. The error for the bend measurements were calculated the same way as for L=7 m measurements with the measurements for L=30 m as reference. RESULTS Straight pipe with short distance between measurement cross sections The results from the numerical simulations and laboratory experiments are presented as deviation in percent from the reference (magnetic flow meter). Each value from the laboratory tests are mean values taken from 18 runs for the differential sensors and 6 to 12 runs from the absolute sensors. The results from the field measurements are presented in a similar way but with the measurements for L=30 m as reference value. Two main criterions in the IEC 41 are the limits of the measuring length (L>10 m) and the UL relation (UL>50 m 2 /s). Figure 5 and Figure 6 shows results from measurements outside these limitations. For the absolute sensors (Figure 6) reference measurements at 17 m (UL 40 to 100 m 2 /s) were performed for comparison. It can be seen that both the numerical and experimental results follow a similar pattern with a slight difference in magnitude. For both the absolute and differential sensors, the error deviates more from the numerical results with decreasing length. The difference in mean values is similar between both types of sensors but the spread at each measuring length is larger for the absolute sensors, especially for short lengths, see The presented results are extended measurements from the one presented in Jonsson et al [3], where only one absolute sensor was used at each measuring section. This sensor was connected to the 4 pressure taps with plastic tubing and through a manifold. That configuration gives much larger discrepancy of the mean value compared to the numerical for short lengths and low velocities, cf. Figure 8(a) in Jonsson et al [3]. Table 1. Hence, those sensors get a larger relative error compared to the differential sensors. 59

Figure 5: Experimental and numerical flow error with differential pressure sensors at measuring length 3, 6 and 9 m. Figure 6: Experimental and numerical flow error with absolute pressure sensors at measuring length 3, 6, 9 and 17 m. The presented results are extended measurements from the one presented in Jonsson et al [3], where only one absolute sensor was used at each measuring section. This sensor was connected to the 4 pressure taps with plastic tubing and through a manifold. That configuration gives much larger discrepancy of the mean value compared to the numerical for short lengths and low velocities, cf. Figure 8(a) in Jonsson et al [3]. Table 1: One standard deviation of the discharge error for each sensor type and measuring length. Measuring length [m] 3 6 9 17 Differential sensors [%] 0.57 0.31 0.16 - Absolute sensors [%] 1.03 0.55 0.24 0.26 Figure 7 presents the discharge error calculated from measurements performed at L=7 m (8<UL<19) relative to the one performed at L=30 m (36<UL<68). The error is plotted versus the guide vane opening where 100% is the opening of the highest tested discharge. The difference between the errors at the two measuring lengths never exceeds 1%. The error follows a random pattern and no U dependency can be found. Furthermore, measurements at the length of 30 m follow the IEC 41 standard and should be rather accurate. However, the discrepancies in the measurements are originated in both, and to find the magnitude an accurate reference measurement is needed. 60

Figure 7: Difference between measured discharge for L=7 and 30 m at the Anundsjoe power plant, Sweden. MEASUREMENTS WITH BEND Figure 8 shows the differences in the calculated mean values for the cases 2x90 degrees and 2x45 degrees bends versus the straight pipe reference. There is a 0.9% underestimation in the flow calculated with 2x90 degree bends compared to the straight pipe reference. The results for the 2x45 degree bends gave approximately the same result as the straight pipe. For both cases, the difference is found nearly constant, and independent of flow velocity. Furthermore, the spread for both cases are in the same range as for straight pipe, see Table 2. It can also be seen that the bend angle is an important parameter for the result. Figure 8: Differences between measurements with straight reference and measurements with bends. Table 2: One standard deviation of the mean for each setup (bend) and length. Measuring length [m] 4/3.7 6/5.7 9/8.7 18.7/20 2x90 degree [%] 0.27 0.29 0.22 0.23 2x45 degree [%] 0.43 0.31 0.30 0.33 For the field test there was also an underestimation of the flow when having a bend between the measurement cross-sections. The measured test points and the difference between the bend measurements and the reference are presented in Figure 9. Considering measurement uncertainties and spread of the results, the difference seems also to be constant at approximately -8%, and thus independent of U. 61

Figure 9: Differences between measurements with straight reference and measurements with bend. How relative differences in the geometry for the field measurement compared to the laboratory measurements affects the result can as for now not be explained. The differences are for the field measurements mainly compared to the laboratory: larger pipe diameter larger bend radius relative to pipe diameter only one 90 degree bend pressure transducer placement geometrical perturbation downstream the measuring cross-section A last parameter which can cause differences is the position of measurement cross sections relative to the bend and pipe diameter. Secondary flows and skewed flow velocity distribution in the pipe can be of significance for the calculated result. More detailed analysis on bends within pressure-time measurements can be found in Ramdal et al 0 DISCUSSION AND CONCLUSIONS The numerical and laboratory, when L>6 m, results show an increasing error with decreasing flow rate. For L=3 and 6 m the flow is under estimated for the highest discharge. Since measurements have been made with only one pipe diameter it is not possible to conclude if it is purely velocity or Reynolds number dependent. This behavior may arise from the transient friction during the valve closure. In the pressure-time method the friction is treated as quasi-steady with a friction factor obtained from the initial state and thereafter used during the whole integration. Transient friction during deceleration is complex and only empirical or semi empirical expressions exist. However, in the numerical case the differential pressure is obtained with simulations of a valve closure where the friction is treated as transient with Brunone model. It is then integrated back with pressure-time method that uses quasi steady friction. Thus, this loop may induce the difference between the initial and the pressure-time integrated flow. By implementing transient friction in the pressure-time method it may be possible to reduce this error. Even though it is small in the numerical results compared to the experimental ones, it may give good results for the experimental as well. A more detailed numerical analysis of the above mentioned behavior may point out its origin and velocity/reynolds number dependency. The laboratory results show that it is possible, under certain conditions, to use the pressure-time method at lower L and UL than stated in the IEC 41 Standard. The results from the field test shows that the flow difference obtained with a long and short length is below 1% for all cases. The error is randomly distributed and has a mean of -0.1%. If for L=30 m, measurements are treated as a precise reference, the short measurements will have results within the limit in the standard. Both field and laboratory measurements with bend(s) between the measurement cross-sections have proved to give a constant and water velocity independent underestimation of the flow. However, the laboratory measurements had a much smaller difference compared to the field tests. In the laboratory tests, 62

2x45 degree bends had almost no difference compared to the reference measurements, while the difference was significant with 2x90 degree bends. Such results support the hypothesis that 2 bends may compensate for each other. How different parameters, such as pipe diameter, bend angle and bend radius affect the result of the calculations are topics of interest in future research. It is a goal to get a systematic compensation for the under estimation based on these parameters. Also the measurement cross-sections distance from the bend, and how this affects due to secondary flows and skewed velocity profiles is not known. Finally, more field measurements are necessary and will be performed at a power plant where a permanent ultrasonic system is installed. Even though the accuracy of that equipment are in discussion, it will hopefully, give some answers to questions that have been arisen throughout this work. ACKNOWLEDGEMENTS The authors would like to thank Norwegian Association of Energy Companies (EBL) and Swedish Hydropower Centre (SVC) for financing the test rig in the Waterpower Laboratory. We would also like to thank Statkraft Sweden for allowing research at the Anundsjoe Power Plant. NOMENCLATURE A Cross-sectional area of the pipe [m 2 ] L Measuring length [m] U Initial velocity [m/s] Q Discharge [m 3 /s] ΔP Differential pressure [Pa] q Leakage flow [m 3 /s] ζ Pressure losses [Pa] ρ Water density [kg/m 3 ] REFERENCES [1] Gibson N. R., 1923, The Gibson method and apparatus for measuring the flow of water in closed conduits, ASME Power Division, pp. 343-392. [2] IEC., 1991, International Standard Field acceptance tests to determine the hydraulic performance of hydraulic turbines, storage pumps and pump-turbines. Volume 41, third edition, pp. 146-160, Geneva, Switzerland. [3] Jonsson P. P., Ramdal J. Cervantes M. J., 2008, Experimental Investigation of the Gibson s Method outside Standards, Proceedings of the 24th Symposium on Hydraulic Machinery and System, Foz do Iguacu, Brazil. [4] Ramdal, J., Jonsson, P. P., Nielsen, T. K., Cervantes, M. J., 2009, Finding inertia time constants for bends related to a modified Gibson s method, Proceedings of the 3rd IAHRWG on cavitation and dynamic problems in hydraulic machinery and Systems, Brno, Czech Republic. [5] Ramdal, J., Jonsson, P. P., Nielsen, T. K., 2010, Influence from bends on a pressure-time measurement, Proceedings of the 25th Symposium on Hydraulic Machinery and System, Timisoara, Romania. [6] Toro E. F., 1999, Riemann Solvers and Numerical Methods for Fluid Dynamics A Practical Introduction, Springer, Berlin. [7] Bergant, A., Simpson, A. R., and Vitkovsky, J., 2001, Developments in Unsteady Pipe Flow Friction Modelling, J. Hydraul. Res. 39(3), pp. 249 257. [8] Jonsson P. P., Cervantes M. J. and Finnström M., 2007 Numerical investigation of the Gibson's method: effects of connecting tubing, 2nd IAHR International Meeting of the Workgroup on Cavitation and Dynamic Problems in Hydraulic Machinery and Systems, Timisoara, Romania. 63