HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

Similar documents
HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

RoHS. Versatile. X g. X 2 e

ED 701 General Industry Pressure Transmitter

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Weather Station P03/3-Modbus-GPS for Modbus

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Installation guide 862 MIT / MIR

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Operating Instructions for Digital Manometer. Model: MAN-SD

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Meteorological Station P03/3-RS485-WAGO

A TEST OF THE PRECIPITATION AMOUNT AND INTENSITY MEASUREMENTS WITH THE OTT PLUVIO

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Weather Station P03/3-RS485-GPS with RS485 Interface

Linear measuring technology

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Weather Station P03/3-RS485 with RS485 Interface

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

WEATHER STATION FOR SOLAR FARM MONITORING

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes at any time without notice.

473 Dew Point Hygrometer

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

Rain Collector (# 7852 & 7852M)

473 Dew Point Hygrometer

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

GREAT EXPERIENCE IN MONITORING SYSTEMS CAPACITY ON DEVELOPMENT AND CREATING SOLUTIONS ADVANCED ITALIAN TECHNOLOGY

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Absolute encoders multiturn

Raindrops. Precipitation Rate. Precipitation Rate. Precipitation Measurements. Methods of Precipitation Measurement. are shaped liked hamburger buns!

CapaciTorr HV 200 HIGHLIGHTS

SVH with HYDROVAR (HVL range)

Sensor Guide WS100 Radar Precipitation Sensor

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

CapaciTorr HV Pumps. making innovation happen,together

Operating Manual. English. Compact Weather Station WS200-UMB WS300-UMB WS301-UMB WS400-UMB WS500-UMB WS501-UMB WS600-UMB.

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

PHOENIX CONTACT - 04/2016. Features

Meteorological Service

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed.

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes at any time without notice.

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Innovative Sustainable Technology

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

473-SHX Dew Point Mirror

IDENTIFICATION STS400

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Development of standard calibration equipment for the rain gauges

Field IT 50T Series Transmitters

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Industrial Pressure Transmitter

OPERATING MANUAL. EIB-Kombisensor AS 315 N

Assembly and Operation Manual. April 2016

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Suntracer KNX-GPS. Weather Station. Technical specifications and installation instructions Item number 3093

E8EB-N0C2B E8EB-N0B2B

WEATHER STATION FIELD GUIDE

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Industrial Pressure Transmitter

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Impedance relay and protection assemblies

E2T0 DVP

Monitoring the world around us since Rainfall Measurement

Manual Smart Weather Sensors

RS-C Flexible Reticle Stocker

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

SPECIFICATION SHEET : FHS2-UNV-36L

Relative pressure transmitter type 520

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

Vet Photometer DP 700 Operating Manual. Version V5.9

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Safety Barriers Series 9001, 9002 Standard Applications

POINTS OF CAUTION BEFORE USE...

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

RS 1700/1900/2300/2900 High Density Reticle Stockers

CDS. high density spring connection

ISEmax CAM40/CAS40. Technical Information

Transcription:

HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

[ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the rainfall collected by a 400 cm 2 inlet. The sensor is a load cell located at the base of the rainfall collecting reservoir. The signal of the load cell is processed by the internal electronic board of the rain gauge in order to output the information on the rainfall. Various outputs are available: RS485 with Modbus-RTU or proprietary ASCII protocol SDI-12 Voltage-free pulse contact output The rain gauge is able to provide the total rainfall, the partial rainfall (from the last reset command or from the last reading command), the average rainfall rate in the last minute and in the last hour. The measured rainfall is regularly saved into a non-volatile memory, which retains the information even in case of power failure. The automatic discharge of the rainfall collected allows using a compact and lightweight structure for the installation of the rain gauge. So as to ensure accurate measurement even with low temperature climatic conditions, a version with heating which is automatically activated below +4 C has been developed (HD2016R) so that snow deposits and ice formations are prevented. The corrosion resistant materials used and the absence of moving parts guarantee a reduced maintenance and a long operating life. The rainfall collecting parts are treated with a non-adherent product for a better water flow. The rain gauge is factory calibrated in three points. A self-diagnostic system periodically checks the correct operation of the instrument and reports any anomalies. The multiplicity of outputs makes the rain gauge suitable to be connected to different ac-acquisition systems. For example: The pulse contact output can be connected to the HD2013-DB data logger, to the wireless data loggers of the HD35EDW series provided with input for contact rain gauge (for example HD35EDWH, HD35EDW-MB, HD35EDWPTC, HD35EDLM, etc.) or to a generic pulse counter. The RS485 Modbus-RTU output can be connected to the HD32MT.1 and HD32MT.3 data loggers for weather station, or to the HD35EDW-MB wireless data logger or to any data logger provided with RS485 Modbus-RTU input. The SDI-12 output can be connected to the HD32MT.3 data logger for weather station or to any data logger provided with SDI-12 input. The rain gauge requires 10 15 Vdc power supply. When submitting your order, upon request a bird dissuader, made of eight 3 mm diameter spikes, 60 mm in height, can be installed on the rain gauge. If the discharge of the water collected takes place during a rainfall, a retention valve, located at the top of rain gauge, temporarily holds the current rainfall, so to avoid losing the amount of rainfall that falls while discharging. The rain gauge is equipped with sophisticated features that allow reducing the effects of wind, ensuring a better accuracy and stability of the measurement. An NTC temperature sensor allows keeping under control the internal temperature of the instrument. Filter The breaker plate and the wire mesh filter prevent obstruction of water flow by leaves or branches. They should be cleaned regularly. 2

view from below 6 10 7 9 8 1. Optional flange for the installation of the rain gauge raised above ground. 2. Electronic board housing. 3. M12 connector for the connection of the measuring circuit power supply and signals. 4. Optional support rod for the installation of the rain gauge raised above ground. 5. Optional flat base for fixing the support of the rain gauge raised above ground. 6. Place for the support rod. 7. Discharge of the rainfall collected. 8. Cover of the electronic board housing. To access the electronic board, loosen the 7 screws that secure the cover. 9. Terminal for protective earth connection. 10. Overflow drain. 11. Optional cable for the connection of the measuring circuit power supply and signals. 12. Cable gland for the heater power supply. 13. Port reserved for technical service. 14. Screws for fixing the cylindrical cover. 15. Cylindrical cover. 15 14 1 13 2 12 3 11 4 5 3

TECHNICAL CHARACTERISTICS Power supply Consumption Measuring circuit: 10 15 Vdc Heater: 12 Vdc 10% (only HD2016R) Measuring circuit: ~ 20 ma (~ 1.5 A while discharging, typ. for less than 1 min. with 300 cc and max. 5 min. with full reservoir) Heater: 90 W (only HD2016R) Contact output Isolated NO (Normally Open) contact (R ON 1 k, T ON 60 ms) Digital outputs Resolution Accuracy Operating temperature Heater intervention temperature Reservoir capacity RS485 with Modbus-RTU or ASCII proprietary protocol SDI-12 Rainfall: 0.001 mm Weight: 1 mg Rate: 0.001 mm/h or 0.001 mm/min Temperature: 0.1 C Weight: ± 0.5 g in the entire operating temperature range Temperature: ± 1 C +4 +60 C without heating -20 +60 C with heating (only HD2016R) +4 C (only HD2016R) 3000 g Protection degree IP 64 Collector area 400 cm 2 Minimum section of the wires of the connecting cable Measuring circuit: 0.7 mm 2 (AWG 19) Heater: 2.5 mm 2 (AWG 13, only HD2016R) INSTALLATION The rain gauge can be installed on the ground or raised 500 mm above the ground. Other sizes above the ground are available on request. For ground installation, three adjustable support feet, so that the instrument can be levelled correctly, and holes for fixing to the floor have been provided. RAIN GAUGE GROUND INSTALLATION Bird dissuader Feet Adjustement screws for levelling 4 Floor

For raised installations, a flange to be fastened to the base of the instrument, and on which the support rod must be inserted, is provided. The rod may end with a flange so that it can be fixed to the floor. RAIN GAUGE INSTALLATION RAISED ABOVE GROUND Bird dissuader HD2013.78 HD2016.33K (flange + support rod) Flat base Floor The base of the rain gauge is fitted with a bubble level to place the instrument perfectly levelled. Bubble level 5

ELECTRICAL CONNECTION The measuring circuit power supply and the outputs (RS485, SDI-12 or contact) are connected via the male 8-pole M12 connector of the instrument. Use a cable with a female 8-pole M12 connector and 0.7 mm 2 minimum wires section. Use a shielded cable over long distances. Upon request, CP18 cables with 5 or 10 m standard length are available (other lengths available upon request). Instrument M12 male connector CP18 cable Connector numbering Function 1 Measuring circuit power supply negative (GND) SDI-12 output negative CP18 cable numbering 12, 7, 6 2 Measuring circuit power supply positive (+Vdc) 1, 2, 4 3 Not connected 4 DATA (RS485) 9 5 DATA + (RS485) or SDI-12 line 5 6 1 st pole of the voltage-free contact 8 7 Not connected 8 2 nd pole of the voltage-free contact 11 MODBUS INPUT REGISTERS Register address 0 Content of the status register 1 Not used Datum 2,3 Partial rainfall, in μm, from the last reading command 4,5 Total rainfall in μm 6,7 Partial rainfall, in μm, from the last reset command 8,9 Average rainfall rate, in μm/min, calculated in the last minute 10,11 Average rainfall rate, in μm/h, calculated in the last hour Format 12,13 Rain gauge internal temperature in C 14,15 Rainfall total weight (Pmg) in mg (*) 16,17 Rainfall total weight, in mg, considering the evaporation (Wmg) (*) 18,19 Weight, in mg, of the current reservoir content (Tmg) (*) 20,21 Partial rainfall, in mils, from the last reading command 22,23 Total rainfall in mils 24,25 Partial rainfall, in mils, from the last reset command 26,27 Average rainfall rate, in mils/min, calculated in the last minute 28,29 Average rainfall rate, in mils/h, calculated in the last hour 30,31 Rain gauge internal temperature in F The measures are signed 32-bit values. Two consecutive registers must be accessed to read a measure. Sequence to remove the cylindrical cover from the base of the rain gauge. 6

Removing the cylindrical cover ORDERING CODES HD2016 HD2016R CP 18.5 CP 18.10 HD2013.18 HD2016.29K HD2016.33K HD2016.33K.1 HD2013.78 Weighing rain gauge, area 400 cm 2, Operating temperature from +4 C to +60 C. RS485 Modbus-RTU or SDI-12 output. Voltagefree contact (NO) output. Power supply: 10 15 Vdc. Weighing rain gauge, area 400 cm 2, with heater. Operating temperature from -20 C to +60 C. RS485 Modbus-RTU or SDI-12 output. Voltage-free contact (NO) output. Power supply: 10 15 Vdc for the measuring circuit, 12 Vdc / 90 W for the heater. 12-pole cable. Length 5 m. 8-pole M12 connector on one end, open wires on the other side. 12-pole cable. Length 10 m. 8-pole M12 connector on one end, open wires on the other side. Bird dissuader. Adjustable feet for the ground installation of the rain gauge. Kit of accessories for the installation of the rain gauge raised 500 mm above ground. Kit of accessories for the installation of the rain gauge raised 1 m above ground. Flat base for fastening the support of the rain gauge raised above ground. Reservoir The qualitative level of our instruments is the result of a continuous evolving of the product itself. This may bring to slight differences between what written in the following manual and the instrument you bought. We cannot completely exclude the presence of errors inside the manual, which we apologise for. Data, images and descriptions included in this manual cannot be enforced legally. We reserve the right to perform modifications and corrections at any time without notice. 7

MANUFACTURE OF PORTABLE, BENCH TOP AND PROCESS SCIENTIFIC INSTRUMENTS Current and voltage loop transmitters and regulators Temperature - Humidity, Dew point - Pressure - CO, CO 2 Air speed - Light - Optical Radiation Acoustics - Vibration Data logger - Data logger wireless Microclimate ph - Conductivity - Dissolved Oxygen - Turbidity Elements for weather stations LAT N 124 Signatory of EA, IAF and ILAC Mutual Recognition Agreements Temperature - Humidity - Pressure - Air speed Photometry/Radiometry - Acoustics CE CONFORMITY Directives: Low Voltage Directive 2014/35/EU Electromagnetic Compatibility Directive 2014/30/EU RoHS Directive 2011/65/EU Harmonised standards: Safety EN 61010-1:2010 EMC EN 61326-1:2013 RoHS EN 50581:2012 RoHS 2011/65/EU Delta Ohm srl Via G. Marconi, 5 35030 Caselle di Selvazzano (PD) - Italy Tel. 0039 0498977150 r.a. Fax 0039 049635596 e-mail: info@deltaohm.com Web Site: www.deltaohm.com Made in Italy 00 10.16