Page AC : INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS

Similar documents
Chapter 3. Experimentation and Data Acquisition

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

MEMS Tuning-Fork Gyroscope Mid-Term Report Amanda Bristow Travis Barton Stephen Nary

Circular Motion and Centripetal Force

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Construction of a Vibrating Structure for Demonstration of Vibration Measurement

Week 14 The Simple Pendulum

Summary Notes ALTERNATING CURRENT AND VOLTAGE

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

Simple Harmonic Motion and Damping

Name Class Date. RC Circuit Lab

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

MAE106 Laboratory Exercises Lab # 6 - Vibrating systems

Mechanical and Acoustical Resonators

AN AUTOMATED GONIOPHOTOMETER FOR LUMINAIRE CHARACTERIZATION

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

DEVELOPMENT OF A NOVEL ACTIVE ISOLATION CONCEPT 1

Simple circuits - 3 hr

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Cambridge International Examinations Cambridge Ordinary Level

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

10 Measurement of Acceleration, Vibration and Shock Transducers

EXPERIMENTAL DETERMINATION OF DYNAMIC CHARACTERISTICS OF STRUCTURES

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

Investigating the Relationship Between Cavendish Temperature Fluctuation and Torsional Oscillation

Exp. #1-1 : Measurement of the Characteristics of the Centripetal Force by Using Springs and a Computer Interface

Parts II-V Sabbatical Leave Report

Coulomb s law with Cobra3

Newton s Second Law. Sample

THE CONSERVATION OF ENERGY - PENDULUM -

AN-1301 APPLICATION NOTE

AP Physics C Mechanics Objectives

Applied Fluid Mechanics

Applied Fluid Mechanics

Cavendish Experiment Proposal

PHY 221 Lab 9 Work and Energy

Recommended Testing Method of Aluminum Electrolytic Capacitor

PHY 221 Lab 7 Work and Energy

Special edition paper Development of Shinkansen Earthquake Impact Assessment System

Aries. Kapton QFP socket Cycling Test DC Measurement Results. prepared by. Gert Hohenwarter

Silicon Capacitive Accelerometers. Ulf Meriheinä M.Sc. (Eng.) Business Development Manager VTI TECHNOLOGIES

Topic 1.2 Measurement and Uncertainties Uncertainty and error in measurement. Random Errors

Simple Harmonic Motion Investigating a Mass Oscillating on a Spring

Acceleration levels of dropped objects. Technical paper 321

The Acceleration Due to Gravity: Free Fall Name

Hands-on Lab 3. System Identification with Experimentally Acquired Data

Capacitive Sensors. Contents

Double Inverted Pendulum (DBIP)

Partner s Name: EXPERIMENT MOTION PLOTS & FREE FALL ACCELERATION

Homework #1 - September 9, Due: September 16, 2005 at recitation ( 2 PM latest) (late homework will not be accepted)

The secondary winding have equal no. of turns. The secondary windings are placed identically on either side of the primary winding.

Energy Storage and Transfer: Gravitational Energy. Evaluation copy. Vernier Photogate (Extension only)

Study of Rupture Directivity in a Foam Rubber Physical Model

Equilibrium in Two Dimensions

Kinematics. Become comfortable with the data aquisition hardware and software used in the physics lab.

A Rain Sensitive House Window Closes Automatically When Raining

Variable Capacitance Accelerometers: Design and Applications

Varuvan Vadivelan. Institute of Technology LAB MANUAL. : 2013 : B.E. MECHANICAL ENGINEERING : III Year / V Semester. Regulation Branch Year & Semester

ELG4112. Electromechanical Systems and Mechatronics

Ruby crystals and the first laser A spectroscopy experiment

Lecture T2 The Pendulum-Based Start Gate (US 8,016,639 B2)

Class #12: Experiment The Exponential Function in Circuits, Pt 1

AC : ENGINEERING SQUEEZEOMETER AND HUGGOME- TER

Moment and angular momentum

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Spring Thing: Newton s Second Law. Evaluation copy

CAL GAUSS CALIBRATION MAGNET

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Motion on a linear air track

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

O P E R A T I N G M A N U A L

Forced oscillation - Pohl s pendulum with measure Dynamics. Equipment TEP

AE2610 Introduction to Experimental Methods in Aerospace DYNAMIC RESPONSE OF A 3-DOF HELICOPTER MODEL

Inverted Pendulum System

HIGHLY ACCURATE PENDULUM INSTRUMENT ECE-492/3 Senior Design Project Spring 2013

Simple Harmonic Motion *

SCLPX - An Alternative Approach to Experiments in Physics Lessons at School

YTÜ Mechanical Engineering Department

Work and Energy. computer masses (200 g and 500 g) If the force is constant and parallel to the object s path, work can be calculated using

Unit assessments are composed of multiple choice and free response questions from AP exams.

Angular Momentum. Brown University Physics 0030 Physics Department Lab 4

7.Piezoelectric, Accelerometer and Laser Sensors

STUDENT EXPERIMENTS PHYSICS, CHEMISTRY & BIOLOGY

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

AC : EXPERIMENTALLY DETERMINING MASS MOMENT PROPERTIES

THE EFFECT OF REVERSAL ON CAPACITOR LIFE

Basic Principle of Strain Gauge Accelerometer. Description of Strain Gauge Accelerometer

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Level

Work and Energy. This sum can be determined graphically as the area under the plot of force vs. distance. 1

Experiment A11 Chaotic Double Pendulum Procedure

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

14300 Dynamics Carts w/o Hoops Teachers Instructions

Activity P15: Simple Harmonic Oscillation (Force Sensor, Photogate)

o0, and since the period of vibration of the scale is related to the mass,

July 19 - Work and Energy 1. Name Date Partners

Vacuum Kelvin Force Probe Research Richard Williams August 1st 2008

Transcription:

AC 2010-2123: INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS Randy Buchanan, University of Southern Mississippi Steven Bunkley, University of Southern Mississippi American Society for Engineering Education, 2010 Page 15.756.1

Instrumentation for Impact Analysis Abstract A test apparatus and appropriate instrumentation were designed by a student with the help of a faculty, to test the deceleration time of a specified impact force applied to a test subject. The apparatus was made to be adaptable to different configuration requirements of future research. This apparatus utilized the accelerating force of gravity in a procedure known as drop testing, in which the test subject is placed at the base of the apparatus. A measured mass is then raised to a calculated height, where the potential energy is released as the mass is guided along a path to impact the test subject. An accelerometer was used to indicate the velocity and deceleration time, to verify the impact force, and calculate the impact rating of the test subject. The data was converted into useful graphs of acceleration, force, velocity, and position in respect to time. The accelerometer contained an internal voltage regulator and an oscillator and produced a signal that was modulated to represent the acceleration experienced by the accelerometer. The data from the procedure was stored electronically for calculations, analysis, and documentation. Results of the experimentation provided much insight into the varying characteristics of different materials to absorb the energy of physical impact. The paper will discuss the design process, the instrumentation involved, and the results of the tests as well as related student learning. Introduction The researchers were tasked with creating a method of determining the mechanical characteristics of various materials used in sports protective gear, particularly mouthpieces. A notable corporate sponsor approached the university about conducted related research. Faculty, facilities, and a graduate student were identified and put in place to accomplish the requested goals. Unfortunately, at the onset of the economic downturn, the company withdrew its support. By this time, the interested faculty and student had already identified the needed apparatus and methodologies. Existing instrumentation was identified to perform the task, as well as a minimal amount of budget reserves to purchase ancillary items. The test apparatus design was modified to fit the existing instrumentation and available resources. Test Apparatus The apparatus used was designed to utilize gravitational acceleration for consistent and repeatable results. Several differing configurations were considered throughout the design and even construction process. The final arrangement made use of two angle bars as guides for a solid rectangular mass, as shown in Figure 1. The mass can be freely lifted vertically along the guide rails to max height difference of 87.6 cm (34.5 in). The rigidity of the structure is maintained by two supports of metal plumbing pipe bolted to the base and top of the front half of the structure. The back part of the structure is bolted directly to a concrete wall. The base of the Page 15.756.2

structure uses an optical table for its rigidity, consistency, ease of positioning, and versatility. The impact surface is a machined block of aluminum similar to the drop mass. A small block of wood is placed between the mass and the impact surface to protect the integrity of the impact zone while not in use. The guide rails are held to the block and the top via angle brackets. Counter sunk bolts connect the brackets to the rails without impeding the fall of the mass. The top is constructed from wood and is used as a shelf to house much of the required instrumentation. Sensors and Instrumentation A capacitive accelerometer was implemented as part of the instrumentation to measure the acceleration of the mass though its fall and immediately after. Capacitive accelerometers utilize the changing distance between its plates to generate an electrical signal that is proportional to the applied acceleration. Given a known seismic mass of an accelerometer, it actually provides an indication of the force incumbent on the accelerometer, which is proportional to the acceleration through Newton s second law Figure 1. Test Fixture F = ma Figure 2. Accelerometer in "0 g" State 1 Since the internal structure of the accelerometer is that of a variable capacitor, force on the device causes the mass to move a distance closer to one electrode, equal but opposite to the distance from the opposing electrode. A diagram of the sensor is shown in Figure 2 in a 0 g state and in Figure 3 in a +1 g state. The distance (x) moved is not only a function of the applied force, but also the spring constant (k) as in Hooke s Law defined as F = -kx The change in capacitance that results from the change in plate distance is given by Figure 3. Accelerometer in "+1 g" State 1 Page 15.756.3

Where C is capacitance, A is electrode area, d is distance between mass and electrode, and x is displacement of the mass. The physical properties of the accelerometer included sensitivity of 102 mv/(m/s^2), a frequency range of 0 to 100 Hz, and a 10 Hz phase response of under 3 1. The accelerometer contains a voltage regulator integrated within its structure. This allows for external power to be supplied by any source within the 10 to 30 VDC excitation range. The change is capacitance is detected by a capacitance bridge where each arm of the bridge functions as a capacitance divider. The outputs of the bridge are then amplitude modulated signals that are directly proportional to the changes in capacitance. A series of diodes and capacitors within the accelerometer are used to demodulate the signals which are then summed, amplified, and filtered to provide a voltage signal that is proportional to the acceleration. Figure 4. Accelerometer Mounting The accelerometer is adhered to the top of the mass so that it can measure its movement as it impacts the test subject, as shown in Figure 4. Wires from the accelerometer are positioned free to move as not to obstruct the freefall of the object. This unobstructed movement is accomplished by tethering the wires to a block positioned at the midpoint of the accelerometers range of motion and ultimately connects to the power supply and the data acquisition module through a series of wiring terminal blocks. The collected data was then subsequently graphed as acceleration, force, velocity, and position in respect to time. The output of the accelerometer is passed to a data acquisition module. The module is designed to take analog voltages from instrumentation and perform analog to digital conversion. The converter used in this case provides wire terminals for the analog signals and a USB connector for connection to a computer. The digital information available at the USB port is thus transferred to a computer. A computer with virtual instrumentation software was used to acquire the digital data and display pertinent values on the screen. A graphical user interface, as shown in Figure 5, was developed to display this data, as well as providing operator control of testing, such as starting and stopping the data collection, and calculating the drop elevation for a desired impact force. Test Procedure The response to mechanical force impacted on a mouthpiece material was induced by impacting it with a direct force of 200 N. The measurement of the deceleration of the impacting mass upon the material may then be used to provide an indication of the protection provided by the material. Through this method of impact testing, various materials could be consistently characterized and ranked for their relative protective capabilities. Page 15.756.4

Figure 5. Graphical User Interface The accelerometer requires approximately fifteen minutes for orientation before a critical measurement. A timer was built into the data collection program to easily ensure that this time constraint is followed. The program also calculates the height to raise the impacting mass to achieve a desired force over a measured object. Due to its extreme sensitivity, the accelerometer is vulnerable to a discernible amount of noise. This noise can greatly influence the measured results over time. The program adjusts to filter this noise while the graphs are not running. The specifics of how this is done without altering the data are discussed under Data Collection and Analysis. Before conducting the experiment, the established procedure allows the program to adjust for noise by ensuring the graphs are not running before starting the program. Procedurally, the operator of the experiment must first raise the mass to height as specified by the program. The height is displayed once the user enters desired impact force in Newtons. The graphs are then initiated to establish baseline reference. The operator then ensures that all graphs are reading as expected and before releasing the mass. After the impact, all graphs are turned off, and the program stopped, thus completing the test. Page 15.756.5

Data Collection and Analysis The accelerometer transmits data as a varying dc waveform, and inherent noise in the signal can alter reliability of the data. All mathematical altercations of the signal stream were performed within the virtual instrumentation software. To filter the noise, the signal is first averaged over time. When the graphs are started the averaging stops and locks the current average into a variable. The previous average is then subtracted from current signal. This quickly and easily eliminates much of the noise and the offset due to gravity, but a constant signal of zero has not yet been achieved. Now the program passes the signal through a comparator. If the absolute value of the new average of the signal over time is less than.02v then it is removed completely, eliminating noise while not affecting the experiment. The signal is then divided by the sensitivity of the accelerometer to determine acceleration. This acceleration can now be multiplied by the mass given previously to calculate height. The velocity is derived by taking the integral of acceleration. Position is derived by taking the integral of velocity. The program is designed to do all mathematical functions automatically, as well as save each experiment s data to a separate spread sheet file. Results Initial testing consisted of two samples that were tested three times each. Both samples were cut from the same material for proof of consistency. The samples were made of ethylene vinyl acetate, the copolymer of ethylene and vinyl acetate, a common material used in sports mouthpieces and other protective equipment. The width of each sample was measured after each test run, as shown in Table 1. Table 1. Calculated Deceleration Distance Test Run Sample 1 Sample 2 Pre-Test 0.365cm 0365cm Test 1 0.360cm 0.360cm Test 2 0.355cm 0.355cm Test 3 0.350cm 0.350cm The sample width represents the hypothetical deceleration distance that can be experienced by the impacting mass. Therefore this number was used to calculate the height required to lift the mass to achieve a desired impact force of 200N. Since the width in practice never approaches zero, the use of the full width results in a resultant impact force that is slightly higher than that calculated. Data from each test run on each sample were recorded and subsequently plotted, as shown in Figures 6 through 11. The graphs are plotted in the dependent variable force (Newtons) vs. the independent variable time (sec). Page 15.756.6

Figure 6. Impact Force of Sample 1 Test 1 400 300 200 100 0 100 200 300 1 Figure 7. Impact Force of Sample 1 Test 2 400 300 200 100 0 100 200 1 31 61 91 121 31 61 91 121 151 181 211 241 151 181 211 241 Figure 8. Impact Force of Sample 1 Test 3 271 271 301 301 331 331 361 361 391 391 421 421 451 451 481 481 511 511 541 541 571 571 601 601 631 631 661 661 691 691 721 721 751 751 781 781 811 811 841 841 871 871 901 901 931 931 961 961 991 991 Page 15.756.7

400 300 200 100 0 100 200 300 1 Figure 9. Impact Force of Sample 2 Test 1 Figure 10. Impact Force of Sample 2 Test 2 400 300 200 100 0 100 200 300 1 31 61 91 31 61 91 121 121 151 151 181 181 211 211 241 241 271 271 301 301 331 331 361 361 391 391 421 421 451 451 481 481 511 511 541 541 571 571 601 601 631 631 661 661 691 691 721 721 751 751 781 781 811 811 841 841 871 871 901 901 931 931 961 961 991 991 Figure 11. Impact Force of Sample 2 Test 3 Page 15.756.8

Each graph contains three bursts of amplitude over time, as well as minor ringing before and after. The first burst on each graph represents the initial impact. Following bursts represent rebound forces resulting from impact, or bouncing. Variances in time as displayed on the individual graphs are the result of human variability in releasing the falling mass relevant to the starting of the data collection, and are inconsequential. Peak for from each impact test is shown in Table 2. Table 2. Measured Force from Impact Tests Test Run Sample 1 Sample 2 Test 1 282 N 296 N Test 2 295 N 287 N Test 3 294 N 290 N Average 291 N 291 N Data for sample one indicates that each measurement is within xx% of the average for that sample. Furthermore, two samples of the same material demonstrated similar characteristics. Variances can be attributed to human error in positioning of the elevated mass before releasing for impact. Student Learning A first-semester graduate student was assigned to the project for the purposes of acquainting the student with instrumentation and computer hardware. The student s undergraduate background was computer science, so he had little to no actual hardware experience. Furthermore, the student had never been exposed to experimental research. Fortunately, the student put forth the effort to learn the necessary components related to the research, and successfully completed the project. Feedback from the student indicated that he not only learned from this project, but the project also helped him understand and related unfamiliar subjects he was currently taking that semester. On many occasions, the student would bring other students into the lab to show them what he had accomplished and this exposed other student to experimental research and a learning process different from traditional classes. Conclusions The research project began with high expectations and an anticipated high level of support. Although all support was retracted, the project continued with minimal resources. Various aspects of the project, such as automated mass positioning, were scraped, in favor of manual methods. The test apparatus proved to be sturdy and dependable, even though it was constructed out of scrap materials and minimal purchases from the local hardware store. Fortunately, the research group had need instrumentation within the lab to complete the fabrication of a working test apparatus. Results of initial testing were positive, and the testing demonstrated reasonable repeatability of measurement. Surprisingly, the test configuration as designed requires human interaction, but Page 15.756.9

the effect of such on the results appears to be minimized. More tests were conducted and very similar results were obtained repeatedly. Improvements to the test fixture could be made, should funding become available. Primarily, the positioning of the mass could be automated, such that the mass could be placed at a specified height with a known level of accuracy. For example, the mass could be integrated to a vertical positioning table to provide positioning within 0.001 of an inch. Relevant to the original research, a force sensor could be placed beneath the test material on the subsurface, to provide an indication of shock, transmitted force, and an indication of energy dissipated by the material. The effects on the graduate student engaged in the project appeared to be the most beneficial outcome. Overall, the student learning component of the project was a success, and the excited student subsequently disseminated his learning outcomes and excitement to other students. Bibliography 1. PCB Electronics Vibration Division. Model 3701G2FB3G Capacitive Accelerometer Installation and Operating Manual. Depew, NY: PCB Electronics Page 15.756.10