SYNCHROTRON X-RAY MICROBEAM CHARACTERIZATION OF SMECTIC A LIQUID CRYSTALS UNDER ELECTRIC FIELD

Similar documents
X-RAY MICRODIFFRACTION STUDY OF THE HALF-V SHAPED SWITCHING LIQUID CRYSTAL

High-speed infrared phase modulators using short helical pitch ferroelectric liquid crystals

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Fast-Response Infrared Ferroelectric Liquid Crystal Phase Modulators

ELECTROOPTIC AND DIELECTRIC PROPERTIES OF NEW ANTIFERROELECTRIC LIQUID CRYSTAL MIXTURES. Chalmers University of Technology, S Göteborg, Sweden;

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

V-shaped switching ferroelectric liquid crystal structure stabilized by dielectric surface layers

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

Field-Dependent Tilt And Birefringence Of Electroclinic Liquid Crystals: Theory And Experiment

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Evidence for de Vries structure in a smectic-a liquid crystal observed by polarized Raman scattering

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

object objective lens eyepiece lens

Polarity-directed analog electro-optic switching in a low-polarization chiral smectic liquid crystal with positive dielectric anisotropy

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

2D XRD Imaging by Projection-Type X-Ray Microscope

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

Laser-Modulator System

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Title. Author(s)Bourny, Valéry; Fajar, Andika; Orihara, Hiroshi. CitationPhysical Review E, 62(5): R5903-R5906. Issue Date Doc URL.

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

The ideal fiber pattern exhibits 4-quadrant symmetry. In the ideal pattern the fiber axis is called the meridian, the perpendicular direction is

Supporting Information

Molecular orientational properties of a high-tilt chiral smectic liquid crystal determined from its infrared dichroism

ANALYSIS OF AN UNUSUAL LIQUID CRYSTAL PHASE TRANSITION

(-)-ISOPINOCAMPHEOL SUBSTITUTED MESOGENS: AN INVESTIGATION OF THE EFFECT OF BULKY TERMINAL GROUPS IN CHIRAL SMECTIC LIQUID CRYSTALS

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Check the LCLS Project website to verify 2 of 6 that this is the correct version prior to use.

Diffractometer. Geometry Optics Detectors

Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

Strain and Stress Measurements with a Two-Dimensional Detector

ON THE COEXISTENCE OF SmC* AND SmC A * PHASES IN BINARY CHIRAL-DOPANT ANTIFERROELECTRIC MIXTURES

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

Diffraction light modulator based on transverse electro-optic effect in short-pitch ferroelectric liquid crystals

Early Development of Dispersive X-Ray Absorption Spectrometer and Recent Extension of Dispersive Optics to Quick X-ray Reflectometory

Experiments on deflection of charged particles using silicon crystals at. Proton Synchrotron (KEK(

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

AP5301/ Name the major parts of an optical microscope and state their functions.

Electro-Optic and Dielectric Study of the de Vries- Type Smectic A* Phase Exhibiting Transitions to Smectic-C*A and Smectic-C* Phases

Supplementary Figure 1: Crystal structure of CRCA viewed along the crystallographic b -direction.

RADIATION SOURCES AT SIBERIA-2 STORAGE RING

Two-dimensionally periodic phases in mixtures of compounds made of rodlike and bent-core molecules

EUV Reflectivity measurements on Acktar Sample Magic Black

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Supplementary Information

Undulator Commissioning Spectrometer for the European XFEL

A NEW SMALL ANGLE X-RAY SCATTERING TECHNIQUE FOR DETERMINING NANO-SCALE PORE/PARTICLE SIZE DISTRIBUTIONS IN THIN FILM

A New Technique for the Observation of X-ray CTR Scattering by Using an Imaging Plate Detector

Development of 2-Dimentional Imaging XAFS System at BL-4

Research with Synchrotron Radiation. Part I

SUPPLEMENTARY INFORMATION

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

MP5: Soft Matter: Physics of Liquid Crystals

XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY

Dielectric Spectroscopy of De Vries Smectic Liquid Crystals

A B. What s a Liquid Crystal? G = H - TS K = [B]/[A] K = e - G/RT

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

AN EXAFS STUDY OF PHOTOGRAPHIC DEVELOPMENT IN THERMOGRAPHIC FILMS

The MID instrument.

The European XFEL in Hamburg: Status and beamlines design

Basics of Synchrotron Radiation Beamlines and Detectors. Basics of synchrotron radiation X-ray optics as they apply to EXAFS experiments Detectors

Development of a High-Speed VUV Camera System for 2-Dimensional Imaging of Edge Turbulent Structure in the LHD

Anomalous orientation of ferroelectric liquid crystal films in an electric field

Supporting Information

Liquid Crystals IAM-CHOON 1(1100 .,4 WILEY 2007 WILEY-INTERSCIENCE A JOHN WILEY & SONS, INC., PUBLICATION. 'i; Second Edition. n z

Beamline Practice at BL02B2 (Powder diffraction)

DEVELOPMENT OF MEASURING SYSTEM FOR STRESS BY MEANS OF IMAGE PLATE FOR LABORATORY X-RAY EXPERIMENT

Ferro-electric SmC* elastomers Mark Warner Cavendish Laboratory, Cambridge.

Transient Electro-Optic Properties of Liquid Crystal Gels

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

David Martin Challenges in High Precision Beamline Alignment at the ESRF FIG Working Week Christchurch New Zealand 2016

Introduction to Synchrotron Radiation

Astronomy 203 practice final examination

Development of New MicroStrip Gas Chambers for X-ray Applications

ANTIFERROELECTRIC LIQUID CRYSTALS WITH 45 TILT - A NEW CLASS OF PROMISING ELECTRO-OPTIC MATERIALS

Development of Target Injection and Tracking for IFE in Japan

Evidence for Triclinic Symmetry in Smectic Liquid Crystals of Bent-Shape Molecules

Knot undulator to generate linearly polarized photons with low on-axis power density. Abstract

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Observation of ferroelectric domains in bismuth ferrite using coherent diffraction techniques

The Study of Charge Carrier Transports in the Calamitic Liquid Crystals 5, 5 -di-(decyl-pyridin-yl) - 2 Bithiophene.

Initial Results on the Feasibility of Hybrid X-Ray Microscopy

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

Local Atomic Image of 0.02 % Zn in GaAs Wafers Using X-ray Holography

Design of multilayer X-ray mirrors and systems

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

In Situ High-Temperature Study Of Silver Behenate Reduction To Silver Metal Using Synchrotron Radiation

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

Lab #13: Polarization

PRINCIPLES OF PHYSICAL OPTICS

X-ray non-resonant and resonant magnetic scattering Laurent C. Chapon, Diamond Light Source. European School on Magnetism L. C.

SSRL XAS Beam Lines Soft X-ray

Two-Stage Chirped-Beam SASE-FEL for High Power Femtosecond X-Ray Pulse Generation

Transcription:

73 SYNCHROTRON X-RAY MICROBEAM CHARACTERIZATION OF SMECTIC A LIQUID CRYSTALS UNDER ELECTRIC FIELD Atsuo Iida 1), Yoichi Takanishi 2) 1)Photon Factory, Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho Tsukuba, Ibaraki 305-0801, Japan 2) Department of physics, Faculty of science, Kyoto University, Kitashirakawa-oiwake, sakyou-ku Kyoto 606-8502, Japan ABSTRACT When an electric field is applied to chiral smectic A (SmA) liquid crystals, a tilt is induced in the director of orthogonal SmA liquid crystals (electroclinic effect). The layer shrinkage due to the tilted smectic arrangement is mitigated by local layer deformation. This paper presents detailed measurements of the local layer spacing under the electroclinic effect of the chiral SmA phase in a surface-stabilized liquid crystal cell, performed using time-resolved synchrotron X-ray microbeam diffraction with a high-resolution CCD X-ray detector. It is shown that the layer spacing variation corresponds well to the applied electric field and the horizontal chevron angle. Further, techniques for the simultaneous measurement of layer deflection and molecular orientation are discussed. INTRODUCTION The electroclinic effect (Garoff and Meyer, 1977) induces a tilt in the director of orthogonal smectic A (SmA) liquid crystals near the SmA chiral smectic C (SmC*) phase transition under the application of an electric field. This phenomenon has attracted considerable attention for understanding the electro-optical behavior of pre-transition phenomena in liquid crystals (Lagerwall, 1999; Williams et al., 1991). A study of the dynamics of the layer structure as well as the molecular orientation is important in understanding the electro-optical behavior of a surface-stabilized liquid crystal cell. One of the characteristic features of the layer structure is the formation of the so-called chevron layer due to the shrinkage in the layer spacing induced by molecular tilt under an electric field (Shao et al., 1991; Rieker et al., 1987; Selinger et al., 2000). A striped texture along the layer normal usually appears in connection with the chevron structure when observed under a polarizing optical microscope. Recently, the static and dynamic local layer structures in the electroclinic effect have been analyzed in detail by time resolved X-ray microdiffraction using synchrotron X-rays (Iida et al, 2005). As the applied field increased, the layer structure of the electroclinic liquid crystal changed from the bookshelf to the compound chevron, and

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

74 subsequently, it changed to the horizontal chevron (Fig.1). The direct result of the electroclinic effect is the molecular tilt in relation to the layer normal along with layer shrinkage, while the layer deformation (such as the formation of the chevron layer structure) is induced by the interaction between molecules and the alignment film of the surface-stabilized cell. A previous study has reported the relation between the molecular orientation and the layer deformation (Iida et al., 2010). In addition, although we carried out the preliminary layer spacing measurement during the electric field application (Iida et al, 2005), the precision of the measurement was not satisfactory. In the present study, the layer spacing dependence on the applied electric field is measured in order to examine the direct effect of the applied electric field with sufficient accuracy. The layer spacing dependence and its relation to the layer structure is also discussed. Furthermore, the techniques for the simultaneous measurement of the layer spacing, layer deformation and the molecular orientation were tested preliminarily in order to overcome the change in the layer response characteristic under prolonged electric field application (Iida et al, 2005). EXPERIMENTAL The sample and the cell alignment condition are the same as previous experiments (Iida et al, 2010). A ferroelectric liquid crystal sample was TK-C101 (Chisso) (Takanishi et al., 1996) and was sandwiched between ITO-coated glass plates (80 m thick) with Fig.1 Schematic drawing of layer structures of the smectic liquid crystal in the surface stabilized cell. Coordinates and rotation axes are also shown. X-rays are incident along Z axis. and are the layer deflection angles.

75 (a) (b) Fig.2 Two dimensional X-ray diffraction patterns on an X-ray CCD camera obtained from SmA liquid crystals. (a) A part of the Debye ring from a powder-like sample. (b) the time resolved layer reflection pattern obtained from the aligned sample in the surface stabilized cell. Horizontal and vertical directions approximately correspond to the change in the layer spacing and the rotation. A field of views of the square image is 24 mm on a side. The darker part corresponds to the higher intensity. polyimide alignment films. The phase sequence is isotropic (80ºC) N* (70ºC) SmA (56 C) SmC*. The experiments were performed in the SmA phase at 0.5 C to 1.0 C above the phase transition temperature. The cell gap was about 7 m. The X-ray experimental conditions are briefly described. The synchrotron X-ray micro-diffraction experiments were carried out on beam-line 4A at the Photon Factory. A combination of a double multilayer monochromator and Kirkpatrick Baez mirrors was used for X-ray optics. The beam size was slightly less than 5 5 m 2 and the angular divergence of the incident beam was approximately 0.7 mrad in the horizontal direction. The X-rays were incident on the sample normal to the cell surface. The rubbing direction was set to horizontal. For the layer diffraction measurement, the incident X-ray energy used was 9.5 kev. We used an image intensified CCD X-ray camera (Hamamatsu C4880-50) with a pixel size of 23.4 m; this size is approximately 5 times smaller than the pixel size used in the previous measurement (Iida et al, 2010). The X-ray detector was placed 175cm away from the sample. Fig.2(a) shows a section of the Debye ring obtained from the sample without the alignment process (powder pattern) ; this ring was used as a reference to correct the layer spacing variation. Several experimental arrangements were tested for the simultaneous measurement of the layer deformation, molecular orientation and the layer spacing. These are described in the following section.

76 LAYER SPACING VARIATION DUE TO ELECTROCLINIC EFFECT The time resolved measurement of the electroclinic liquid crystal was carried out in the quasi-static mode using a triangular waveform electric field (10 Hz, ±25 V). The diffraction data within a certain measurement time were summed and stored separately. In the present case, one cycle of the triangular field was divided into 24 subdivisions so that the time resolution was 4.17 ms (voltage resolution was 4.17 V). Fig.3(a) shows the angular intensity distribution obtained in the time integration mode, in which the integrated intensity of the layer diffraction peak during the electric field application was measured as a function of the sample position across the striped texture (Y), i.e., normal to the rubbing direction and parallel to the layer (see Fig.1). The peaks at near = 0 (central peak) and = (side peak) are due to the horizontal chevron and vertical chevron, respectively. It is seen that the compound chevron is realized from the alternate intensity variation between the central and the side peaks, and its periodicity is approximately 10 m. Fig.2(b) shows an example of the time resolved reflection pattern obtained at = 0 for an applied field between 20.8 V and 25 V. Two separate diffraction spots are due to the horizontal chevron. The time resolved angular distribution obtained at = 0 and Y = Fig.3 (a) Series of -profiles as a function of the vertical position (3 m step in Y-direction). (b)time resolved -profiles for a half cycle (50 ms) of the triangular wave form (10 Hz).

77 9 m as a function of time (applied electric field) for a half cycle of the triangular wave form is shown in Fig.3(b). The chevron angle depends on the applied field. Since the beam divergence due to the focused microbeam was large (0.7 mrad), the center of mass for each diffraction pattern was calculated, and the geometrical deformation of the diffraction pattern was corrected using the reference data (Fig.2(a)). Fig.4 shows the relative layer spacing variation d/d 0, where d 0 denotes the layer spacing without an electric field, and d represents the change in the layer spacing from d 0, as a function of time (applied field) during a half cycle of the applied field. The molecular tilt is proportional to the magnitude of the applied field. In addition, the layer spacing deduced from the horizontal chevron angle ( d/d ~ 2 / 2) is shown. The layer spacing changes during the field application: further it corresponds to the chevron angle. The previously reported preliminary results (Iida et al, 2005) were thus clearly confirmed. Fig.4 Relative layer spacing variations as a function of time (applied electric field) (closed circle) and that obtained by the layer deflection angle of the horizontal chevron (open circle). SIMULTANEOUS MEASUREMENT OF LOW- AND WIDE-ANGLE SCATTERING As shown in our previous paper (Iida et al, 2005), the chevron formation depends on the history of the applied electric field; prolonged application of the electric field changes the bookshelf to the compound chevron and subsequently to the horizontal chevron. This layer structure change is due to the interaction between the electroclinic effect and the anchoring effect at the alignment interface. A simultaneous measurement of the molecular orientation and the layer orientation (chevron angle) or the layer spacing is much preferable to sequential measurements in order to characterize the electroclinic effect quantitatively, since the sequential measurements may lead to analysis of different layer structures. The molecular orientation can be obtained by means of wide angle halo scattering with a detector placed near the sample, while the layer structure is measured by means of a low angle Bragg reflection with a high resolution detector set at a distance from the sample. Two types of simultaneous time resolved measurement systems are preliminarily examined in the study. When a 6 in. image intensified X-ray CCD camera was used for recording the full halo

78 pattern, the resolution for the low angle layer diffraction was poor. A method to improve the low angle scattering resolution is to move the camera downstream and record the layer diffraction and the halo pattern by using incident X-rays of the fundamental energy and those of higher harmonics, respectively (dual energy technique). This arrangement can be realized, because a conventional Si (111) double crystal monochromator has third and higher harmonics. The halo pattern appears perpendicular to the layer diffraction, consequently, each scattering does not overlap. Since the double multilayer monochromator was used in the present experiment, the second harmonic appeared. Fig.5(a) shows the overlapped diffraction pattern of the halo and the layer diffraction in the vertical and horizontal directions, respectively. The fundamental energy value for the layer diffraction was 8 kev and an absorber was inserted to reduce the incident X-ray intensity in order to avoid radiation damage of the liquid crystal sample. Though the second harmonic is weak due to the low critical energy of the Photon Factory 2.5 GeV ring (4 kev), two sets of scattering appear separately. If this technique is used at the higher critical energy beamline (e.g., the wiggler beamline or a beamline on the high energy third generation ring), the intensity of the higher harmonics is much stronger than the one shown in Fig.5(a). The resolution for the low angle scattering can be greatly improved in this case. This technique is used for obtaining the layer scattering and the halo scattering simultaneously with one detector and can be easily extended to the time resolved measurement. If another two dimensional (2D) detector is placed near the sample to obtain the halo pattern in addition to the present experimental arrangement, two scattering are obtained simultaneously with different detectors. A simultaneous time resolved measurement can be realized by applying the same gate signal to both detectors. Fig.5(b) shows one halo pattern obtained by a compact pixel array detector (PILATUS 100K, Dectris) placed 18cm away from the sample. The layer diffraction was obtained simultaneously with a high resolution CCD, in a manner similar to the one obtained in Fig.2(b). Due to the high signal to noise ratio of the pixel array detector, no background subtraction was required in order to obtain the pattern Fig.5 Simultaneous measurement of the layer diffraction (red arrow) and halo pattern (black arrows) obtained by a dual energy technique (a) and the halo pattern by a two 2D detectors system (b).

79 shown in Fig. 5(b). underway. The simultaneous time resolved measurement with this scheme is now In summary, the layer spacing in the electroclinic effect of the chiral smectic A phase in the surface stabilized cell near the phase transition temperature has been measured in detail using the time resolved synchrotron X-ray microbeam diffraction technique with a high resolution CCD X-ray camera. The layer spacing change during the field application well corresponds to the chevron angle. Further, techniques which measure the layer deflection and the molecular orientation simultaneously have been examined. ACKNOWLEDGEMENTS The authors would like to thank Dr. Y.Takahashi and Ms.Y.Ohtsuka for their help during experiments. They would also like to thank the staff of PF for their help during experiments. This work was carried out under the approval of the Photon Factory Advisory Committee (Proposal No. 2008G697 and 10G682). REFERENCES Garoff, S., and Meyer, R.B., (1977), Electroclinic effect at the A-C phase change in a chiral smectic liquid crystal, Phys. Rev. Lett. 38, 848-851. Iida, A., Takahashi, Y., Takanishi, Y., Nakata, M., Ishikawa, K., and Takezoe, H., (2005), Dynamic and microscopic X-ray characterization of a compound chevron layer in electroclinic liquid crystals, Liquid Cryst., 32, 717-726. Iida, A., Takahashi, Y., Takanishi, Y., (2010), X-ray characterisation of local molecular orientation in the electroclinic effect of surface-stabilised SmA liquid crystals, Liquid Cryst., 37, 1091-1096. Lagerwall, S. T., (1999), Ferroelectric and Antiferroelectric liquid crystals (Weinheim, Wiley) Rieker, T. P., Clark, N. A., Smith, G. S. S., Parmar, D. S., Sirota, E. B., and Safinya, C. R., (1987), "Chevron" local layer structure in surface-stabilized ferroelectric Smectic-C cells, Phys. Rev. Lett. 59, 2658-3661. Selinger, J.V., Xu, J., Selinger, R.L.B., Ratna, B.R., and Shashidhar, R., (2000), Theory of chiral modulations and fluctuations in smectic-a liquid crystals under an electric field, Phys. Rev., E 62, 666. Shao, R.F., Williams, P.C., and Clark, N.A., (1991), The field induced stripe texture in surface stabilized ferroelectric liquid crystal cells, Ferroelectrics, 121, 127-136. Takanishi, Y., Iida, A., Ishikawa, K., Takezoe, H., and Fukuda, A., (1996), Spontaneous layer twist in a stripe texture of chiral ferroelectric smectics observed by synchrotron x-ray microdiffraction, Jpn. J. Appl. Phys., 35, 683-687. Williams, P.A., Clark, N.A., Ros, M.B., Walba, D.M., and Wand, M.D., (1991), Large electroclinic effect in new liquid crystal material, Ferroelectrics, 121, 143-146.