Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Similar documents
Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

The Development of ZrO 2 Based HPLC: From Colloid to Column

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases

Characteristics and Advantages of Zirconia-Based Stationary Phases for Use in Multi-Dimensional HPLC

Retention and Selectivity Variables

Multi-mode Separations Using Zirconiabased Stationary Phases

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

New Applications of Zirconia Based Stationary Phases

Method Development on Next Generation RPLC Supports

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Isomer Separation on ZirChrom -CARB

Method Development with ZirChrom's Ion Exchange Phases

Analytical Advantages of Highly Stable Stationary Phases for Reversed-Phase LC

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Packings for HPLC. Packings for HPLC

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

RP C18 column with feature of a silanol group

Method Development Kits

Inertsil ODS-EP Technical Information

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

Reversed Phase Solvents

mau 200 ph min

Optimisil HPLC & UPLC Column catalogue

Improving HPLC Column Selection and System Performance

Xiqin Yang, Jun Dai, Peter W. Carr* Chemistry Department University of Minnesota

Reversed-Phase Method Development Guide

High Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger

Optical Isomer Separation Columns and Packing Materials

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Advantages of polymerbased. an alternative for ODS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

TCI Dual ~Mixed-Mode Mode column~

1. What is the major organic product obtained from the following sequence of reactions?

N_HW1 N_HW1. 1. What is the purpose of the H 2 O in this sequence?

HPLC Column Product Guide

Overview Applications of NUCLEODUR HPLC Phases

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Gemini-NX Performance paired with Axia Technology

The Standard for ph Method Development

Oligonucleotide Separation on ZirChrom -SAX

TCI Chiral HPLC Column

Small Molecule Selectivity Sampler

Analysis - HPLC A.136. Primesep 5 µm columns B.136

HPLC Column Classification

Technical Guide Thermo Scientific Syncronis HPLC Columns

A C18 Silica Column With Exceptional Temperature and ph Stability

Comparison of different aqueous mobile phase HPLC techniques

Alltech Alltima HP Introduction

Optimizing GPC Separations

LC and LC/MS Column Selection Flow Chart

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Your Reversed Phase Method

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Solid Phase Micro Extraction of Flavor Compounds in Beer

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Shodex TM ODP2 HP series columns

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Capacity vs Throughput on Modified Macrocylics in Reversed Phase, Polar Ionic Mode and Normal Phase

Hypersil BDS Columns TG 01-05

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Cation Exchange HPLC Columns

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

1. CONCEPTS IN ORGANIC CHEMISTRY 2. SYNTHETIC ORGANIC CHEMISTRY 3. ISOMERISM II 4. HYDROCARBONS II 5. HALOALKANES. Vikasana - CET 2012

8. Methods in Developing Mobile Phase Condition for C18 Column

for Acclaim Mixed-Mode WCX-1

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

HPLC Column Product guide

Setting the Standard for ph Method Development

Comparison Guide to C18 Reversed Phase HPLC Columns

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

ChromegaChiral TM CSP Media and Columns

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Carbonaceous RPLC Stationary Phases Based on Porous Zirconia STABILITY is the Name and SELECTIVITY is the Game Paul T. Jackson

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

LC Columns with Liquid Separation Cell Technology

Fast Separation of Vastly Different Compounds by Isocratic HPLC

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

637. Thiamethoxam. HPLC method

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

HPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

BETASIL Columns TG Å high purity silica

CHEM340 Tutorial 4: Chromatography

1. CONCEPTS IN ORGANIC CHEMISTRY 2. SYNTHETIC ORGANIC CHEMISTRY 3. ISOMERISM II 4. HYDROCARBONS II 5. HALOALKANES. Vikasana - CET 2012

PHENOGEL GPC/SEC COLUMNS

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Fluophase and Fluofix Columns

Transcription:

Polymer Coated tania for Analytical and Preparative Reversed-Phase Chromatography Pittcon 2005 CLAYT V. MCEFF 1, BIGWE YA 1, JCHE WIKLER 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka, M 55303 2 Sachtleben, Duisburg, Germany 1-866-STABLE-1 www.zirchrom.com

utline Properties of tania RP Phase Stationary Phase Chromatographic Data Selectivity Comparison of Sachtopore-RP, Silica C18, ZirChrom-CARB, and ZirChrom-PBD Effect of Lewis Base Mobile Phase Additive on Elution of Basic Compounds Chemical and Thermal Stability Testing Conclusion - The Sachtopore -RP shows very similar selectivity to ZirChrom -PBD and has excellent stability from ph 1-12 and up to 100 o C.

Element Electronic Structures Silicon (element 14; 2.3 g/cc; Si 4+ ionic radius 0.400 Å) e3s 2 3p 2 tanium (element 22; 4.5 g/cc; 4+ ionic radius 0.605 Å) Ar3d 2 4s 2 Zirconium (element 40; 6.5 g/cc; Zr 4+ ionic radius 0.720 Å) Kr4d 2 5s 2 All have four valence electrons so some chemistry is similar, but presence of d orbitals and very electropositive nature allow and Zr (metals) to form strong electron donor-acceptor complexes (coordination chemistry).

Surface Chemistry of tania- Based Supports for HPLC H H H 2 H H 2 H 2 Weak Brönsted Acid: Weak Brönsted Base: Strong Lewis Acid: + H + H + H2 P + H + P - H SCX mode

tania Crystal Forms Crystallographic data and pi values of sorbents Anatase (tetragonal), 300 o C Rutile (tetragonal), 600 o C Brookite (orthorhombic), 850 o C. Si 2 2 Al 2 3 Zr 2 Ionisation potential (V) 45.14 (Si 4+ ) 43.27 ( 4+ ) 28.45 (Al 3+ ) 34.34 (Zr 4+ ) Coordination number 4 6 6 7 Ion radius (A) 0.41 (Si 4+ ) 0.68 ( 4+ ) 0.5 (Al 3+ ) 0.8 (Zr 4+ ) Ionisation potential/coordination number (V) 11.29 7.33 4.74 4.83 pi of sorbent (ph) 2.2 6.6 8.1 6 Porosities of test columns (%) 73 74 79 69 Anatase Rutile

Polyethylene Coated tania [ CH 2 -CH ] 2 n Polyethylene H H H 2 H H 2 H 2

22 on-electrolyte Solutes onpolar Benzene Toluene Ethylbenzene p-xylene Propylbenzene Butylbenzene Cl Polar Br Cl Bromobenzene p-dichlorobenzene Anisole Methylbenzoate aphathalene Acetonphenone 2 C 2 2 Cl Benzonitrile itrobenzene p-itrotoluene p-itrobenzyl Chloride Benzophenone Cl HB Donor H H H H H H Benzylalcohol 3-Phenyl Propanol -Benzyl Formamide Phenol p-chlorophenol

Selectivity Comparison 2.000 1.500 ZirChrom-PBD ZirChrom-CARB Silica C18 Sachtopore -RP 1.000 0.500 0.000-0.500-1.000 benzyl formamide benzyl alcohol phenol 3-phenyl propanol p-chlorophenol acetophenone benzonitrile nitrobenzene methylbenzoate anisole p-chlorotoluene p-nitrobenzyl chloride benzophenone bromobenzene naphthalene p-xylene p-dichlorobenzene -1.500 benzene toluene ethyl benzene propyl benzene butyl benzene Solute LC Conditions: Mobile phase, 40/60 AC/Water; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5ul; Detection at 254nm. log (k' Solute/k' benzene)

κ-κ Comparison 45.0 k' (PBD, CARB, C18) 40.0 35.0 30.0 25.0 20.0 15.0 Sachtopore -RP vs Silica-C18 Sachtopore -RP vs ZirChrom-CARB Sachtopore -RP vs ZirChrom-PBD R 2 = 0.911 R 2 = 0.036 10.0 5.0 R 2 = 0.992 0.0 0.00 1.00 2.00 3.00 4.00 5.00 k' (Schtopore RP) LC Conditions: Mobile phase, 40/60 AC/Water; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5ul; Detection at 254nm. Reference: Melander, W.; Stoveken, J.; Horvath, C. J. Chromatogr. 1980, 199, 35-56.

Chemical Stability ph 1.0 ph 12.0 6.0 6.0 toluene toluene k' 4.0 methyl benzoate k' 4.0 Methyl benzoate 2.0 anisole 2.0 anisole Benzonitrile 0.0 0 1000 2000 3000 4000 5000 Column Volumes 0.0 Benzonitrile 0 1000 2000 3000 4000 5000 Column Volumes Exposure and Evaluation Conditions: Mobile phase, 15/85 AC/0.1M itric acid, ph 1.0, or 0.01M Tetramethylammoniumhydroxide, ph 12.0; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5 µl; Detection at 254 nm; Column, 50 mm x 4.6 mm i.d. Sachtopore -RP.

Temperature Stability at 100 o C 3.0 toluene 2.0 k' 1.0 methyl benzoate anisole Benzonitrile 0.0 0 1000 2000 3000 4000 5000 6000 Column Volumes Exposure and Evaluation Conditions: Mobile phase, 15/85 AC/water; Flow rate, 1.0 ml/min.; Temperature, 100 o C with Metalox heater; Injection volume, 5 ml; Detection at 254 nm; Column, 50 mm x 4.6 mm i.d., Sachtopore -RP.

Effect of Lewis Base Additive on Separation of Basic Drugs 2 1 3 4 5 A 2 1 3 4 5 B 1 2+3 4 C 5 0 2 4 6 8 10 12 14 16 18 min Chromatographic Conditions: Column 50X4.6 mm Sachtopore -RP, Mobile phase: 30/70 AC/20 mm buffer (ph=7). (A) ammonium acetate, (B) ammonium fluoride, (C) ammonium phosphate. flow rate: 1ml/min, temperature: 40 o C. Wavelength: 254 nm. Solutes: (1) lidocaine, (2) quinidine, (3) tryptamine, (4) amitriptyline, and (5) nortriptyline.

Effect of Ionic Strength on Separation of Basic Drugs (A) 10 mm 1 2 3 4 5 2 1 3 4 5 (B) 15 mm 1 2+3 4 5 (C) 20 mm 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 min Chromatographic Conditions: Column 50X4.6 mm Sachtopore -RP, Mobile phase: 30/70 AC/phosphate buffer (ph=7). (A) 10 mm, (B) 15 mm, (C) 15 mm. flow rate: 1ml/min, temperature: 40 o C. Wavelength: 254 nm. Solutes: (1) lidocaine, (2) quinidine, (3) tryptamine, (4) amitriptyline, and (5) nortriptyline.

Antihistimines Separation at ph 10 45,0 mau 230 nm 40,0 H CH 3 5 H CH H 3 C 30,0 1 2 4 1: maleic acid 4: Diphenylpyraline Cl 20,0 2: Carbinoxamine Cl CH3 H 3 C 5: Phenyltoloxamine 10,0 3: Chlorphenamine 0,0-5,0 0,0 2,0 4,0 6,0 8,0 min 10,0 12,0 15,0 LC Cconditions: Mobile phase, 74% (50 mm H 3 P 4 + 5 mm KH 2 P 4 ), 26% AC, ph 10; Flow rate, 1.0 ml/min.; Temperature, Ambient; Injection volume, 20 µl; Detection at 220 nm; Column, Sachtopore -RP (300 Å, 3 µm, 150x4 mm).

Separation of Basic Cardiac Drugs at ph 10 33,0 mau 230 nm H H 3 C H C H 3 H 25,0 1 2 3 H 3 C 1: Trapidil H H 3 C C H 3 H 3 C H 3 C 2: Metoprolol I H H H 5: Dipyridamole C H 3 20,0 2 I 3: ifedipine 4: Amiodarone H 3 C C H 3 15,0 5 7: Etafenone 6 H 3 C C 10,0 4 H 3 C H 3 C C H 3 C H 3 6: Verapamil 7 5,0-1,0 0,0 2,0 4,0 6,0 8,0 10,0 12,0 15,0 LC Cconditions: Mobile phase, 70% (10 mm Borax + 10 mm Soda), 30% AC, ph 10; Flow rate, 1.0 ml/min.; Temperature, Ambient; Injection volume, 20 µl; Detection at 230 nm; Column, Sachtopore -RP (300 Å, 3 µm, 150x4 mm). min

Semi-Prep Separation of Pentifylline (vasodilator) 1800 SLB16 #69 A15 UV_VIS-1 mau 280 nm Particle Sizes: 3,5,10,20,40,80 100 micron 1 mm 1500 1250 1000 750 Pores sizes: 60, 100, 300, 500, 1000, 2000 Angstroms 500 250 0 min -200 0,0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 LC Cconditions: Mobile phase, (+ 10 mm a 2 B 4 7 + 1 mm H 3 B 3 ), ph 8.8; Flow rate, 1.0 ml/min.; Temperature, Ambient; Injection volume, 20 µl; Detection at 254 nm; Column, Sachtopore -RP (300 Å, 3 µm, 150 x 4 mm).

Conclusions The Sachtopore -RP shows similar selectivity to ZirChrom -PBD (DS-like for neutrals). The Sachtopore -RP has excellent stability from ph 1-12 and up to 100 o C. The type of Lewis base buffer has a profound effect on selectivity for Sachtopore -RP. Basic (amine) analytes generally undergo RP/CEX mixed-mode retention mechanism on Sachtopore -RP.

Acknowledgments Dr. Jochen Winkler Sachtleben Dr. Bingwen Yan - ZirChrom Visit Us at Booth 2801 1-866-STABLE-1 www.zirchrom.com For more information and web access to the free Buffer Wizard: www.zirchrom.com