Fabric Medley Manufacturer Gabriel A/S

Similar documents
Fabric RUNNER Manufacturer Gabriel A/S

Fabric EVENT SCREEN Manufacturer Gabriel A/S

Fabric HUSH Manufacturer Gabriel A/S

Fabric XPRESS Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Curtain fabric type Ace Manufacturer Kvadrat A/S

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Fabric REFLECTACOUSTIC

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Roller blind fabric PRIMACOUSTIC R

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Renolit stretch ceilings

Sound insulation of planted noise barriers

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

Acoustic test report AU01+N01

Inspection Report. Coating name: IGP DURA xal IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

Testing of Lincolnshire Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

TFI Report Sound Absorption Impact Sound Insulation

Tests on glasswool air conditioning duct according to EN Pressure losses tests

Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests

RIVERBANK ACOUSTICAL LABORATORIES

CERTIFICATE OF ACCREDITATION

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

A L I O N Technical Center. Test Report

RIVERBANK ACOUSTICAL LABORATORIES

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

REPORT issued by an Accredited Testing Laboratory

TFI Report Impact Sound Insulation

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Testing of Ancaster Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

REPORT issued by an Accredited Testing Laboratory

Measurement of sound absorption coefficient for Fraster felt SpaceCover

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

CERTIFICATE OF CALIBRATION

TFI Report Impact Sound Insulation

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

Report. Laboratory for Acoustics

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

Test Report EN (2008)

Measurement of Acoustic Properties of light weight concrete SL-Deck

GESELLSCHAFT FÜR ELEKTRISCHE HOCHLEISTUNGSPRÜFUNGEN Mitglied der Short-Circuit-Testing Liaison (STL) Test Report

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

UN Regulation No. 118 Annex 8

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

REPORT OF SPECIAL TEST

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Dwelling Airtightness Testing Report

Testing Procedure: AS ISO

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

TEST CERTIFICATE PARTIAL REPRODUCTION OF THE PRESENT CERTIFICATE IS PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION BY EKANAL.

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

STATISTIQUE DE PERFORMANCE

REPORT N CR

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Measuring Viscosity. Advanced Higher Physics Investigation. Jakub Srsen SCN: Boroughmuir High School Center Number:

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

Appendix B1. Reports of SMU

Collector test according to EN ,2:2002

Dwelling Airtightness Testing Report

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

CERTIFICATE OF CALIBRATION

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Health Based Building Limited MgO Magnum Board Flexural Testing

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Hillsborough Appendix B: Cone Penetration Testing

The information included in the following report presents the results of sound pressure and sound power testing.

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

Displacement Flow Diffusers

M. A. Navacerrada, C. Díaz, A. Pedrero and L. Iglesias

Evaluation of in-plane orthotropic elastic constants of paper and paperboard

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

WeatherHawk Weather Station Protocol

Transcription:

Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com 2015-06-09 Fabric Medley Manufacturer Gabriel A/S Determination of the airflow resistance according to EN 29053 Test Report No. M104146/23 Client: Consultant: Accredited testing laboratory according to ISO/IEC 17025 Gabriel A/S Hjulmagervej 55 9000 Aalborg Denmark Date of report: 2015-06-09 Delivery date of test objects: 2015-06-03 Date of test: 2015-06-08 Total number of pages: In total 9 pages: 4 pages text, 3 pages Appendix A and 2 pages Appendix B. Müller-BBM GmbH HRB Munich 86143 VAT Reg. No. DE812167190 Managing directors: Joachim Bittner, Walter Grotz, Dr. Carl-Christian Hantschk, Stefan Schierer, Elmar Schröder, Norbert Suritsch

Inhaltsverzeichnis 1 Task 3 2 Basics 3 3 Test objects 3 4 Execution of measurements 3 5 Measurement results 4 6 Remarks 4 Appendix A: Appendix B: Measurement results and evaluation List of test equipment 2015-06-09 Page 2

1 Task On behalf of Gabriel A/S, DK 9000 Aalborg, the airflow resistance of three samples of the fabric type Medley was to be determined according to EN 29053 [1]. 2 Basics This test report is based on the following document: [1] EN 29053: Acoustics Materials for acoustical applications Determination of airflow resistance. 1993 3 Test objects The tested fabric is described in table 1. The indicated characteristic values were determined by the testing laboratory on the basis of the sample. Table 1. Test object. Test object (manufacturer s information) Area specific mass m [g/m²] Thickness d [mm] Appendix A, page Sample 1: Fabric type Medley, manufacturer Gabriel A/S material: 100 % polyester Sample 2: Fabric type Medley, manufacturer Gabriel A/S material: 100 % polyester Sample 3: Fabric type Medley, manufacturer Gabriel A/S material: 100 % polyester 355 0.66 1 347 0.65 2 345 0.67 3 4 Execution of measurements The airflow resistance was determined according to EN 29053 [1]. The test method, the test facility and the test equipment used are described in Appendix B. 2015-06-09 Page 3

5 Measurement results For the tested fabric type Medley a specific airflow resistance of was determined. R s = 1471 Pa s/m The determined air flow resistances of each of the three samples are shown in table 2. The measurement results are shown in diagrams and tables in the test certificate in Appendix A of this report. Table 2. Determined airflow resistances of the fabric Medley. Test object Airflow resistance R s [Pa s/m] Appendix A, page Sample 1: Fabric type Medley Sample 2: Fabric type Medley Sample 3: Fabric type Medley 1458 1 1499 2 1456 3 Mean value 1471 6 Remarks The test results exclusively relate to the investigated subjects and conditions described. M.Eng. Philipp Meistring This test report may only be published, shown or copied as a whole, including its appendices. The publishing of excerpts is only possible with prior consent of Müller-BBM. 2015-06-09 Page 4

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10233 Test object: fabric Medley, sample no. 01 colour: 61002 composition: 100 % polyester Diameter: 100 mm Thickness: 0.66 mm Area-specific mass: 355 g/m 2 Barometric pressure: B = 95,7 kpa Temperature: θ = 26,3 C Relative humidity: r. h. = 44,6 % 1800 1600 1400 m ars 1.2.5253.15707 - S:\M\Proj\104\M104146\MarsData\2015-06-08\Medley_01.mrs (10.06.2015) u/ R s / (mm/s) (Pa s/m) 1.15 1450 1.78 1459 2.42 1461 3.06 1458 3.69 1454 4.33 1451 4.97 1451 5.60 1451 6.24 1448 Airflow resistance R s /(Pa s/m) 1200 1000 800 600 400 200 0 0 1 2 3 4 5 6 7 Airflow velocity u/(mm/s) Airflow resistance R s = 1458 Pa s/m Laboratory: Responsible: Date: Planegg 2015/06/08 2015-06-09 Appendix A, Page 1

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10234 Test object: fabric Medley, sample no. 02 colour: 61002 composition: 100 % polyester Diameter: 100 mm Thickness: 0.65 mm Area-specific mass: 347 g/m 2 Barometric pressure: B = 95,8 kpa Temperature: θ = 24,6 C Relative humidity: r. h. = 41,6 % 1800 1600 1400 m ars 1.2.5253.15707 - S:\M\Proj\104\M104146\MarsData\2015-06-08\Medley_02-2.mrs (10.06.2015) u/ R s / (mm/s) (Pa s/m) 1.78 1492 2.41 1497 3.04 1494 3.68 1489 4.31 1488 4.94 1488 5.58 1488 6.21 1482 Airflow resistance R s /(Pa s/m) 1200 1000 800 600 400 200 0 0 1 2 3 4 5 6 7 Airflow velocity u/(mm/s) Airflow resistance R s = 1499 Pa s/m Laboratory: Responsible: Date: Planegg 2015/06/08 2015-06-09 Appendix A, Page 2

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10235 Test object: fabric Medley, sample no. 03 colour: 61002 composition: 100 % polyester Diameter: 100 mm Thickness: 0.67 mm Area-specific mass: 345 g/m 2 Barometric pressure: B = 95,7 kpa Temperature: θ = 26,5 C Relative humidity: r. h. = 37,2 % 1800 1600 1400 m ars 1.2.5253.15707 - S:\M\Proj\104\M104146\MarsData\2015-06-08\Medley_03.mrs (08.06.2015) u/ R s / (mm/s) (Pa s/m) 0.51 1456 1.15 1454 1.78 1450 2.41 1457 3.05 1452 3.68 1449 4.32 1447 4.95 1448 5.58 1448 6.22 1445 Airflow resistance R s /(Pa s/m) 1200 1000 800 600 400 200 0 0 1 2 3 4 5 6 7 Airflow velocity u/(mm/s) Airflow resistance R s = 1456 Pa s/m Laboratory: Responsible: Date: Planegg 2015/03/03 2015-06-09 Appendix A, Page 3

Description of the test procedure for the determination of the airflow resistance 1 Measurand The specific airflow resistance R S of the test object was determined. For this purpose the air pressure difference in front of as well as behind the test object was measured at different volumetric airflow rates. The specific airflow resistance R S,I for each volumetric airflow rate q i determined was calculated using the following equation: With R S,i specific airflow resistance in Pa s/m; p i air pressure difference across the test object with respect to the atmosphere in Pa; A q i u i R S, i pi A q cross-sectional area of the test object perpendicular to the direction of flow in m 2 ; volumetric airflow rate passing through the test object in m 3 /s; linear airflow velocity in m/s; i In addition the linear airflow velocity u i was determined: u i qi A The indicated measurement result is the specific airflow resistance R S, which is calculated for an airflow velocity of u = 0.0005 m/s by extrapolation with help of the linear regression. 2015-06-09 Appendix B, Page 1

2 Test procedure The direct airflow method (method A according to EN 29053) was applied. A steady unidirectional airflow with different air flow rates is pressed through the test object in the specimen holder. The resulting pressure drop between the two free faces of the test object is measured. The specimen holder had a diameter of D = 100 mm. 3 List of test equipment The test equipment used is listed in table B.1. Table B.1. Test equipment. Name Manufacturer Type Serial-No. Measurement system airflow resistance Software for measurement and evaluation Müller-BBM M89319-00 315003 Müller-BBM m ars v1.0.0.2 Digital measuring slide Mitutoyo CD-15PPR 07019377 Electronic balance Kern 440-49N WC0633572 2015-06-09 Appendix B, Page 2