PYCKO SCIENTIFIC LIMITED

Similar documents
M E E T I n s t r u m e n t s G.m.b.H.

1 of :32

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

Ion-Chamber Survey Meter OD-02

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Characterization of Large Structures & Components

QuantumMCA QuantumNaI QuantumGe QuantumGold

CHEMISTRY 170. Radioisotopes

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy

Survey Meter OD-01 Address: Phone: Fax: URL:

CHEMISTRY 130 General Chemistry I. Radioisotopes

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Radiation Detection. 15 th Annual OSC Readiness Training Program.

GUIDE TO LABORATORY SURVEYS. Introduction

Recent improvements in on-site detection and identification of radioactive and nuclear material

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

SLAC Radioanalysis Laboratory

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

E THERMADATA LOGGER Humidity & temperature recording meter

RMCC CANBERRA Latest developments

EAS 535 Laboratory Exercise Weather Station Setup and Verification

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Modular Survey Spectrometer and Compton Imager

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

Applied Nuclear Science Educational, Training & Simulation Systems

Identify Isotopes with the ICS-4000 Gamma Ray Spectrometer!

473-SHX Dew Point Mirror

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Alpha-Energies of different sources with Multi Channel Analyzer

GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium

Dual laser + type K thermometer INFRARED THERMOMETER

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Personal Dose Monitoring System

PROFILE S and C Series

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

OXEA - Online Elemental Analyzer

ɣ-radiochromatography

Practical Solutions to Radioactive Waste Characterization

IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO

GEOPHYSICAL GAMMA-RAY SPECTROMETER

"Neutron Flux Distribution"

Comparison of Several Detector Technologies for Measurement of Special Nuclear Materials i

Gamma-Spectrum Generator

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

NUCL 3000/5030 Laboratory 2 Fall 2013

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

PROFILE S and C Series P-type Semi-planar and Coaxial HPGe Detectors

INFRARED THERMOMETER TM0819

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Instruction Manual SEFRAM Thermal Camera

cobas e 411 analyzer Confidence in every result.

GAMMA RAY SPECTROSCOPY

GM Pancake Probe Victoreen Model D

NGN PhD Studentship Proposal

National Event Tree. **Combo Package** Eliminator 2000 Super & National Event Tree. Item # 3152 $849

The Best Gamma-Ray Detector

FoodScreen Radiological Food Screening System

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Acceleration/Velocity/Displacement VIBRATION METER

GM Pancake Probe Victoreen Model D

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

Frazier L. Bronson CHP Canberra Industries, Inc., Meriden, CT USA ABSTRACT

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

Distance from the face of the detector to the surface of the item being measured.

Calibration of the GNU and HSREM neutron survey instruments

Owlstone Nanotech Inc

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

PINS3-CW. Portable Chemical Identification System

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

CapeSym, Inc. Radiation Detection Solutions

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

General Overview of Radiation Detection and Equipment

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

J R. TransTech Systems T S. The World s Number 1 Supplier Of Non Nuclear Density Meters for Asphalt Pavements and Engineered Soils

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

2100TR Liquid Scintillation Counter

Assembly and Operation Manual. April 2016

O P E R A T I N G M A N U A L

Basic hands-on gamma calibration for low activity environmental levels

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

Utilization of advanced clutter suppression algorithms for improved spectroscopic portal capability against radionuclide threats

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

LUDLUM MODEL NEUTRON DETECTOR. December 2017

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

SPECTROPHOTOMETERS. Visible and UV-Visible

Transcription:

PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides with the world s high CZT handheld detector Instrument Features: Accurate dose Dynamic search and alarm capability Automated radionuclide ID for ANSI N42.48 RadBar TM included for spectral dose visualisation Library of 94 radionuclides. User can add custom nuclides for their application Feature locking with PIN codes Fully compatible w spectroscopy software, MultiSpect Analysis TM Detector: The RayMon10TM is the highest resolution CZT handheld radiation monitor in the world. It can be used to detect, measure, identify and analyse gamma ray emitting radionuclides. The CZT detector produces high resolution gamma-ray spectra for clear and unambiguous interpretation. The RayMon10TM algorithms provide spectral dose, radionuclide identification, line analysis and activity quantification. RayMon10TM is robust, lightweight and easy to use; its portability and usability are second-to-none. RayMon detachable probe Energy resolution: 2.0-2.5% FWHM @ 662 kev Energy range: 30 kev to 3.0 MeV enabling high resolution isotope ID using RayMon10TM creates PDF reports including photograph, the latest advances in CZT detector GPS position, radiation technology spectra and spectral analysis, with raw data Hardware: files as attachments. Rugged handheld platform Measurements can be Sunlight-visible VGA display shows transferred easily to a images, maps and data in ultra-sharp PC or laptop, with data detail transfer either via USB, Integrated GPS for location tagging or with reachback over Long-life rechargeable battery - 8 hours wireless, Bluetooth or in continuous use cellular networks. GSM 3G options (optional)

Integrated 5MP camera (optional)

Searching and measuring The search feature makes locating sources easy. As the detector is moved, clear visual graphs show when the count rate is increasing, guiding the user to the position of the source. When exposed to radiation the operator can use the high resolution CZT detector to measure a detailed spectrum of the gamma rays present. This spectrum is used for detailed analysis and can be saved for future reference, along with the location of the measurement and a photograph. Dose RayMon10TM provides accurate dose measurements to the user from both a simple front screen and as part of a gamma ray spectrum measurement. The spectral data is analysed by a Kromek developed algorithm across all energies to give an accurate dose value without the operator having to change any calibration factors. RadBarTM Technology For the first time high resolution CZT technology allows the user to see the dose spectrum clearly in a RadBarTM graphic. When viewed in conjunction with the emission energies of identified radionuclides the major dose contributors can be identified. Automatic Isotope Identification After recording a spectrum, fully automated radionuclide identification, designed to meet ANSI N42.48, can be performed for a library of 18 commonly encountered radionuclides*. Unknown Radionuclide a radiation source present that cannot be identified. Results are clearly ranked for the user with the largest contributor at the top of the results table. Identification can be performed on spectra from a single radionuclide, mixtures, and shielded radionuclides Colour scaling can be configured by the user depending on the application. Alarms is displayed if there is Counts per second alarms are configurable at user chosen levels and clearly visible on the front of the device. The dynamic search alarms, which utilise statistical significance algorithms, can also be configured to the user s needs. * For the list of radionuclides included, see the table on the following page

Exporting Data and ReachBack Communications Spectrum analysis for advanced users For advanced users RayMon10TM contains a detailed library of the emission lines from 94 radionuclides. Libraries can be configured by the user for the radionuclides of most interest. Emission peak parameters are calculated and returned to the user. Detailed.csv reports allow the user to access all measured peak parameter values from the spectrum analysis. After a spectrum has been measured emission lines that pass a statistical critical limit test are highlighted to the user allowing the user to interpret the peaks in the spectrum. RayMon10TM is fully compat desktop PC software MultiSpect AnalysisTM. Spectra, analysis configurations and results can easily be transferred by simply connecting the RayMon10TM to the PC with a USB cable and using the import functions within the MultiSpect AnalysisTM measurements database. The analysis of spectra can then continue with the convenience of a desktop and the extensive radionuclide library available in MultiSpect AnalysisTM. Both RayMon10TM and MultiSpect Analysis TM allow reports to be generated in pdf format of the measurement, including spectrum, peak analysis, radionuclide identification results, and photographs

4 <1min 95% 0.4 <10min 95% 0.1 <1hr 95% Applications include: Decommissioning Environmental Monitoring Waste Disposal Features: Rugged and easy to operate both in field and laboratory use Provides activity analysis in complex spectra where normal detectors cannot be used Can be used with distributed (soil, building material sample, liquid waste) and point source(air sampling filters, calibration sources) samples Unique field reporting technology allows isotope analysis to be tagged to photographs, notes and GPS coordinates and reports to be transmitted directly from the field for immediate response PDF reporting facility Radionuclide library tailored to customer needs Quantitative Analysis with RayMon10 TM Minimum Degree of Detectable Scan confidence Activity (Bq/g) Time in typical for Cs137 background

Quant TM for RayMon10 TM Quantitative activity analysis module provides the complete hardware and software package required for accurate measurements of specific radionuclides. The module is fully ruggedised for field use. Radionuclide Minimum Detectable Activity Cs134 0.1 Bq/g Cs137 0.1 Bq/g Other radionuclides available upon request Accurate measurements of radionuclide activity can now be made in field with the RayMon10 TM using the Quant TM module. Raymon10 TM advanced high resolution detector allows quantitative analysis of isotopes which normally overlap in lower resolution instruments based on LaBr3 or NaI. This unique capability allows rapid in-field analysis and sample classification, avoiding costly delays associated with laboratory or radiochemical analysis. Quant TM is simple to use for distributed or point sources. The beaker and sample collection tools provided allow either sample type to be accurately presented to the detector in seconds. Measurement time is determined by the required MDA and can be executed in minutes. The RayMon10 Quant eliminates the need for lab-based intrusive sampling and radiochemical analysis in order to determine the classification of the material Immediately reported activity results Clearly separated Cs137 energy peak GPS /time / photo capability essential for infield communication and immediate reach back

TECHNICAL DATA POWER ADAPTOR Input: 100 240 V 0.8 0.4 A 47 63 Hz DETECTOR PROBE Output: 5.0V 4.0A Detector: CZT detector 10 x 10 x 10 mm 3 International mains socket adaptors included as standard. High energy resolution: 2.0-2.5% FWHM @ 662 kev Display: 480 x 640 pixel (VGA) 16-bit colour TFT with LED backlight ENVIRONMENTAL Indicator: On screen display confirming detector PDA Unit connected. Dose rate display: µsv / hr Performance is specified at an ambient temperature of Connection: USB 25 C. Operation at extreme temperatures (above 50 C or Detector Testing: Tested by National Physical below 5 C) is not recommended. Meets or exceeds: Laboratory in accordance with the conditions in; ANSI N42.31 (2003) Measurement procedures for resolution and efficiency of wide-bandgap semiconductor detectors of ionizing radiation NPL Good Practice Guide No. 14 The examination, testing and calibration of portable radiation protection instruments Automated Radionuclide ID developed for: ANSI N42.48 (2008) Section 6.10 Requirements for Water: Immersed in 3.3 ft (1 m) of water for 240 minutes MIL-STD-810F, Method 512.4, Procedure I, IEC-529, IP68 Sand & dust: Totally protected against dust MIL -STD-810F, Method 510.3, Procedure I, II, IEC-529, IP68 Drop: 26 drops room temperature from 4 ft (1.22 m) onto plywood over concrete 6 additional drops at 22 F ( 30 C) 6 additional drops at 140 F (60 C) MIL-STD-810F, Method 516.5, Procedure IV Vibration: Spectroscopic Personal Radiation Detectors (SPRDs) General Minimum Integrity and Loose Cargo tests MIL-STDfor Homeland Security 810F, Method 514.5, Procedure I, II Operating Temperature: PERFORMANCE 22 F to 140 F ( 30 C to 60 C) Energy range (Gamma): 30 kev to 3.0 MeV MIL-STD-810F, Method 501.4, Procedure II MIL-STD-810F, Maximum throughput: 30,000 cps High level Method 502.4, Procedure I, II, III Storage Temperature: indicator warning on screen 40 F to 158 F ( 40 C to 70 C) Number of channels: 4096 MIL-STD-810F, Method 501.4, Procedure I MIL-STD-810F, Battery: 5000 mah Li-ion rechargeable module Method 502.4, Procedure I, II, III Temperature shock: giving 8 hours of continuous use -22 F/149 F ( 30 C/+65 C) MIL-STD-810F, Method 503.4, Library: 94 radionuclides Dose rate: Demonstrated up to 1mSv/h@ 662 kev Procedure I Humidity: Dose accuracy: Better than +/- 20% 90%RH temp cycle 32 F/158 F (0 C/+70 C) MIL-STD- Stability: Peak drift +/- 1 channel (4096) over 8 810F, Method 507.4 hours continuous measurement Altitude: Analysis Software: RayMon10 TM Analysis software 15,000 ft (4,572 m) at 73 F (23 C) to 40,000 ft (12,192 m) PDA platform: Windows mobile 6.1 at 22 F ( 30 C) MIL-STD-810F, Method 500.5, Procedure I, II, III PHYSICAL PDA Unit: 17.6 x 19.2 x 15.0 cm Detector Probe IP65 Weight: 769 g EMC tested Probe + Cable: 24 x 4.5 x 4.5 cm Weight: 252 g Recommended service interval: Annual

RayMon10 TM Every Kromek RayMon10TM comes complete in its own heavy-duty weatherproofed and ruggedised Peli Case containing the following items as standard: Ruggedised handheld PC RayMon10TM detector probe Detachable coiled cable Wall charger with universal international plug adapters Accessory/storage pocket Operating manual Test certificates Optional extras: Extra battery pack 12 volt in-car charger 5MP camera module 3G cellular network module