Industrial Resistance Thermometers according to DIN Model MWD

Similar documents
Thermal Mass Flow Meter for Gases

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

Full Metal Variable Area Flow Meter and Counter

Operating Instructions for Digital Manometer. Model: MAN-SD

Oscillation Flow Meter for Gases

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

Infrared Hand-Held Thermometers

Industrial Pressure Transmitter

Infrared Hand-Held Thermometers

Industrial Pressure Transmitter

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure transmitters for industrial applications MBS 32 and MBS 33

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

ED 701 General Industry Pressure Transmitter

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Exchangeable measuring insets SensyTemp TSA101

Pressure Measurement Single-range transmitters for general applications

Pressure Transmitter ED 701

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ATEX/IECEx RTD temperature probe

Temperature sensors SensyTemp TSP311, TSP321, TSP331

HARTING D-Sub Selection Guide

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

ISEmax CAM40/CAS40. Technical Information

Relative pressure transmitter type 520

Electromagnetic Flowmeter

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Direct-operated 2/2-way compact solenoid valves Type EV210A

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Direct-operated 2/2-way solenoid valves Type EV210B

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Mineral-insulated thermocouples to DIN and EN

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

473 Dew Point Hygrometer

Metso Concentration Measurement 3300

473-SHX Dew Point Mirror

Field IT 50T Series Transmitters

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

473 Dew Point Hygrometer

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

Solenoid valves 2/2-way direct-operated type EV210A

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Field mounted Temperature Transmitter TF212/TF212-Ex

Absolute encoders multiturn

Size A DIN EN

RoHS. Versatile. X g. X 2 e

PRODUCT CATALOGUE PREssURE switch

Conductivity sensor for hygienic applications

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

EX-EMERGENCY LIGHT FITTINGS

PHOENIX CONTACT - 04/2016. Features

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS

Pressure. 1 Fitting PA R - N R2

One-hand ph/temperature measuring instrument

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Facts and figures MULTILIFT SELECT 15

Construction and application of resistance thermometers

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

K04 TYPE -40 C +85 C 20000H

Non-Contact Safety Systems CMS

Linear measuring technology

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Display counter electromechanical

Technical specification FLUXUS F502TE

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Surface-mounting Thermostats ATH Type Series

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Temperature Measurement

Transcription:

Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance or analogue 4... 20 ma O O Option: head with HART -protocol or Profibus /Fieldbus, display OProtection O / measuring insert material: steel.4404, others on request T2 /2-208 KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-6579 Hofheim/Ts. Office: +49(0)692 299-0 +49(0)692 23398 info.de@kobold.com

Description KOBOLD temperature assemblies comprise a rugged installation fitting made of steel with thread, flange or weld-on process, a head and a measuring element. A Pt00 temperature sensor according to IEC 75, class A, B, / 3 DIN or / 0 is fitted in the measuring element. On request, the measuring element can be removable, thus, allowing to remove the measuring element without interrupting the process as the customised thermowell remains in the installation and seals the process. Alternatively these sensors can be designed as single or double resistance thermometers, except the 4-wire version, which can only be built with one Pt00 due to lack of space. As an option the resistance thermometers can be supplied with a head. Transmitter with a standard 4-20 ma signal, with HART protocol or with Profibus /Fieldbus are there to choose from. Transmitter Resistance thermometers with head are used whenever a measuring signal must be transported long distance without any disturbance. The head which is encapsulated in epoxies resin is located right in the head and delivers a temperature-linear output signal of 4-20 ma. The head is available with standardised communication systems just like HART protocol or Profibus /Fieldbus. Applications OO HVAC OO Machinery OOChemical and petrochemical industries OOHeating /cooling processes OOIndustrial uses in general The resistance thermometers with thread and flange are favourably used for the temperature measurement in liquids, solids and gaseous media. The reliable water tightness of these installation methods for gauge pressure and vacuum is an important criteria for selection. Technical Details Measuring principle: temperature depending resistor Measuring range: -70...+250 C -70 +400 ºC -70 +600 ºC -98 +00 ºC Sensor: Pt00 single or double sensor ( x Pt00 or 2 x Pt00) IEC 75 Accuracy: class A, class B, /3 DIN, /0 DIN Ambient temperature: -40...+50 C with ceramic terminal block (without ) -40...+85 C (with ) -20...+70 C (with LCD display) -20...+80 C (with LED display) Connection head: BR screwed cover, with chain, DIN B cover with two screws, BUZ, hinged cover BUZ-H, high model hinged cover and others Electrical : M20 x.5 standard (others on request) Materials: Sensor: steel.4404 Connection head:, painted, steel, and PP (others on request) Terminal block: ceramic (without ) : Thread: G ¼, G ½, G ¾, G male, ¼" NPT, ½" NPT, ¾" NPT, " NPT male DIN-flange: DN 5, 20, 25, 32, 40, 50 PN 0, 6, 40 ANSI flange: ½", ¾", ", ½", 2" class 50, class 300 Max. pressure: Sensor wiring: Output: 30 bar 2, 3 or 4-wire resistance value Protection: head IP 54... 68 depending on cable gland Measuring insert exchangeable Protection / P max MWD-C, E, D yes yes / 30 bar MWD-F, G, W ) yes no / P atm MWD-A, B, L no yes / 30 bar ) F/G/W only with thermowell TWL-0 2 /2-208

EL MWD-A compact compression fitting Sensor element: Pt 00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D /2-208 MWD-A Protective diameter (D) 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 000 = none K5 = compression fitting G½-M C5 = compression fitting ½" NPT-M XX A = x Pt 00 class B B = 2 x Pt 00 class B C = x Pt 00 class A D = 2 x Pt 00 class A E = x Pt 00 class B F = 2 x Pt 00 class B G = x Pt 00 class A H = 2 x Pt 00 class A I = x Pt 00 class B J = 2 x Pt 00 class B K = x Pt 00 class A L = 2 x Pt 00 class A M = x Pt 00 class /3 DIN (-70 N = x Pt 00 class / 0 DIN (-70 O = x Pt 00 class / 3 DIN (-70 P = x Pt 00 class / 0 DIN (-70 RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay Q = x Pt 00 class (-98 +00 ºC) ) Only without 2) Please specify the measuring range in clear text, while ordering 3) With x Pt00 only 4) For A, B, C, D choose RTD wiring code»3«note: Please specify length»el«in clear text, while ordering 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to 3

EL MWD-L compact fixed thread Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D MWD-L Protective diameter (D) 3 = Ø3 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G-M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 RTD wiring 2 = 4 3) = 4-wire Q = x Pt00 class (-98 +00 ºC) ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to Note: Please specify length 'EL' in clear text, while ordering 4 /2-208

HL=30 EL 2 ø0 HL=30 EL ø0 MWD-B compact threaded or flanged with neck pipe Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D D /2-208 Protective diameter (D) G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M F5 = DN5 PN6 F20 = DN20 PN6 F25 = DN25 PN6 F32 = DN32 PN6 MWD-B 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 F40 = DN40 PN6 F50 = DN50 PN6 H5 = DN5 PN40 H20 = DN20 PN40 H25 = DN25 PN40 H32 = DN32 PN40 H40 = DN40 PN40 H50 = DN50 PN40 A5 = ½"CL50 RF A20 = ¾" CL50 RF A25 = " CL50 RF A40 = ½" CL50 RF A50 = 2" CL50 RF B5 = ½" CL300 RF B20 = ¾" CL300 RF B25 = " CL300 RF B40 = ½" CL300 RF B50 = 2" CL300 RF XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of ) Only without 2) Please specify the measuring range in clear text, while ordering 3) With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering Y = acc. to 5

EL MWD-C compact with removable measuring insert Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772 steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D MWD-C Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G-M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 6 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

EL MWD-E compact with removable measuring insert and compressing fitting Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772 steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D MWD-E Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 000 = none K5 = compression fitting G½-M C5 = compression fitting ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class /0 DIN (-70 O = x Pt00 class /3 DIN (-70 P = x Pt00 class /0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208 ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 7

HL=30 EL 2 ø0 HL=30 EL ø0 MWD-D compact with removable measuring insert and extension neck pipe Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772 steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D D MWD-D Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M F5 = DN5 PN6 F20 = DN20 PN6 F25 = DN25 PN6 F32 = DN32 PN6 F40 = DN40 PN6 F50 = DN50 PN6 H5 = DN5 PN40 H20 = DN20 PN40 H25 = DN25 PN40 H32 = DN32 PN40 H40 = DN40 PN40 H50 = DN50 PN40 A5 = ½" CL50 RF A20 = ¾" CL50 RF A25 = " CL50 RF A40 = ½" CL50 RF A50 = 2" CL50 RF B5 = ½" CL300 RF B20 = ¾" CL300 RF B25 = " CL 300 RF B40 = ½" CL 300 RF B50 = 2" CL 300RF XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 8 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

EL MWD-F compact fixed thread with removable measuring insert ), for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others : threaded Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection /2-208 MWD-F Measuring insert diameter (d) 3 = Ø3 4 = Ø4 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D 4-20 ma with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to 9

HL=30 EL 2 ø0 HL=30 EL MWD-G compact with removable measuring insert ) and neck pipe, for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection MWD-G Measuring insert diameter (d) 3 = Ø3 4 = Ø4 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire 0 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering Y = acc. to /2-208

EL HL=50mm Dd MWD-W compact with removable measuring insert ) and neck pipe (nipple union nipple), for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 50 mm, (nipple union nipple) Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection Measuring insert diameter (d) 3 = Ø3 4 = Ø4 MWD-W N5 = ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208 ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering

ML MWD-M measuring insert Sensor element: Pt00 3-wire class B, A, /3, /0,, and others : ceramic terminal block or Max. pressure: atmospheric pressure Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Measuring insert diameter (d) 3 = Ø3 4 = Ø4 MWD-M 00 A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class (-98 +00 ºC) RTD wiring 2 = 4 ) = 4-wire 2 Terminal head ) 2) With x Pt00 only Please specify measuring range in clear text while ordering. Only possible for wiring code '3' 3) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'ML' in clear text 3), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus /Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

MWD-S Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: 30 bar (at 20 ºC) only metallic immersion Protection : according to DIN 43763 steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-S 3 = Ø3 ) 4 = Ø4 ) 00 K5 = compression fitting G ½-M C5 = compression fitting ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class (-200 +00 ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector = with spring strain relief Y = according to ) With pot seal Ø6 x 40 for crimping cable /2-208 3

MWD-N Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: 30 bar (at 20 ºC) only metallic immersion Protection : according to DIN 43763 : thread steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC, silicone max. 200 ºC PTFE max. 220 ºC, fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-N 3 = Ø3 4 = Ø4 G08 = G ¼ M G5 = G ½ M G20 = G ¾ M G25 = G M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class (-200 +00 ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector = with spring strain relief Y = according to 4 /2-208

MWD-I Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: atmospheric pressure Handle: PVC material max. 80 ºC Protection : according to DIN 43763 steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-I 3 = Ø3 4 = Ø4 000 = PVC handle XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class (-200 +00 ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector Y = according to /2-208 5

MWD-P Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: atmospheric pressure Handle: PVC material max. 80 ºC Protection : according to DIN 43763 steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-P 3 = Ø3 4 = Ø4 000 = PVC handle XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class (-200 +00 ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector Y = according to 6 /2-208

MWD-T Sensor element: Pt00 3-wire class B, A, /3, /0 Max. pressure: atmospheric pressure Connection head: box or polycarbonate box Protection type: without holes outdoor installation with holes indoor installation Protection : according to DIN 43763 Max. temper. box: aluminum max. 80 ºC polycarbonate max. 80 ºC Aluminium Polycarbonate Immersion diameter RTD wiring Terminal head MWD-T H = Ø6 with holes 00 A = x Pt00 class B (-40 +80 ºC) B = 2 x Pt00 class B (-40 +80 ºC) C = x Pt00 class A (-40 +80 ºC) D = 2 x Pt00 class A (-40 +80 ºC) 2 = 4 = 4-wire A = P = polycarbonate 0 = ceramic terminal A = 5333D 4 20 ma B = 5337D 4 20 ma with HART protocol C = 5350A 4 20 ma Profibus / Fieldbus D = prepared for subsequent mounting of Y = according to /2-208 7

Accessories / Description DOK-FR05 3-point calibration report (additional points possible) DOK-FR03 Inspection certificate 3. Ø 82 Ø 6,5 50 Protection: IP Typ 65G, I, P IP protection Typ M depends on cable gland. Higher IP on request. Ø 82 Ø 6,5 64 38 Ø 23 83 50 87 Ø 33 46 3 Ø 38 55 8 Ø 39 Option K Housing material: steel.440 Typ H Protection: IP 65 Typ Z Housing material: Protection: IP 65 60 78 Ø 23 50 87 Ø 33 64 Ø 23 Terminal s 38 Option G Housing material: 46 I Housing material: 3 steel.440 Ø 38 P Housing material: PP Option Z Note: Housing 38 material: Aluminium 9 Protection: Ø 34 IP 65 Ø 84 Ø 84 Ø 27 83 4 Ø 27 Option M 4 55 8 Ø 39 60 Ø 72 78 Ø 23 72 50 50 Ø 26 8 8 42 42 Ø 28 Ø 28 Typ K 8 Typ B 8 0 5 82,5 85 42 Ø 28 38 9 Ø 34 Typ M Ø 9 /2-208

Terminal s (continuation) Option B Housing material: Protection: IP 54 87 72 Ø 33 Ø 26 50 50 42 8 Ø 28 46 3 Ø 38 Ø 72 Ø 82 Option H Housing material: Typ G, I, P Protection: IP 65 83 Ø 27 4 Typ H 55 8 Ø 39 Ø 84 64 Technical Details Housing material: Supply voltage: 7.5... 45 V DC Output signal: 4... 20 ma Load: max. (V supply 7.5 V)/0.022 A Signal on alarm: underranging: linear drop to 3.8 ma overranging: linear rise to 20.5 ma sensor break, sensor open-circuit: 3.6 ma or 22 ma Galvanic isolation: 2000 V AC (input/output) Response time: s Long term stability: RTDs ±0.% of reading or 0. C Ø 23 38 Ø 6,5 Switch delay: 5 s 38 Influence 9of ambient: negligible Load influence: Ø 34 negligible Power supply Typ M influence: negligible Filter configurating: 0... 60 μa Resolution: 0.3 μa Cable entry: M20 internal thread Ambient temperature: -40... +85 C (-40... 85 F) Storage temperature: -40... +00 C (-40... 22 F) Condensation: allowable Protection: IP 65 Shock and vibration resistance: 4g / 2 to 50 Hz as per IEC 60068-26 LCD-Display, with backlight: 55 visible range 32.5 x 22.5 mm; 8 main display: 5-digit, 7-segment, Ø 39 digit height 8 mm, range: -9999... 99999 Typ Z additional display: 8-digit 4 segment, digit height 5 mm for sensor type and units 83 Ø 27 4 Ø 84 Option E 60 Ø 72 0 82,5 5 85 78 Ø 23 72 50 Ø 26 8 42 04,5 Ø 28 6 50 8 42 Ø 28 Main features Typ K OO High accuracy 0.02% of span for Pt00 sensor 0 O O Sensor error detection 82,5 according to the guidelines in NAMUR NE 89 OOBacklight LCD-Display Typ B 5 85 Ø 9 /2-208 04,5 6 000.0 ºc 9

Terminal s (continuation) Option D/R Main Features p E Ø 9 000.0 ºc OOGraphical display with backlight OOShowing errors and limits by steady or flashing colours OOProgrammable by touch screen OOOption R: two configurable relay outputs Technical Details Input Housing material: steel.430 Measuring range: 3.5 23 ma (normal working range 4... 20 ma) Connections: 2 screw terminals for loop power, signal 4 screw terminals for relay outputs Accuracy: ±0.% of input span within -0... 70 C ±0.2% of input span within -30...-0 C / 70... 80 C Loop voltage drop: two levels depending on chosen backlight brightness at 20 ma: low bright backlight (<40%): max. 4 V at 23 C high bright backlight (>40%): max. 6.5 V at 23 C Sample time: s, typical 0.3 s Start-up time: 5 s User-configurable data Measuring range: 4... 20 ma Error/warning indication: Zoom on range: Damping: Linearisation table: Measuring unit (standard selectable): User defined unit: individually configurable display and backlight indication in white, green or red colour, steady or flashing light; configurable limits between 3.5 and 23 ma minimum 2 ma of input span 0... 30 s 2... 30 points C, F, K 8 x 20 pixels matrix 20 Dec. point position: xxxxx, xxxx.x, xxx.xx, xx.xxx, x.xxxx,.xxxxx, AUTO Display Type: FSTN graphically LCD Measuring range: -9999... 99999 Digit height: max. 22 mm Environmental conditions Optimal readability: -0... 70 C Operating temperature: -30... 80 C Storage temperature: -40... 85 C Mechanical data polycarbonate plastic Enclosure: ø 80 mm housing and front ring steel, AISI 304 Protection: IP 0 on terminals IP 67 in ø 80 mm housing Relay (option R) Contacts: Voltage: Load current: 2 solid state relays 60 Vp 75 ma /2-208

Electrical Connection x Pt00, x Pt00, 3-wire x Pt00, 4-wire 2 x Pt00, 2 x Pt00, 3-wire /2-208 2