very high temperature for excitation not necessary generally no plasma/arc/spark AAS

Similar documents
Chapter 8: An Introduction to Optical Atomic Spectrometry

Chemistry Instrumental Analysis Lecture 18. Chem 4631

high temp ( K) Chapter 20: Atomic Spectroscopy

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

9/13/10. Each spectral line is characteristic of an individual energy transition

Emission spectrum of H

ATOMIC SPECROSCOPY (AS)

3 - Atomic Absorption Spectroscopy

CH. 21 Atomic Spectroscopy

Optical Atomic Spectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

2101 Atomic Spectroscopy

PRINCIPLES OF AAS atomization flame furnace atomization absorption

Atomization. In Flame Emission

Atomic Absorption Spectroscopy (AAS)

Atomic Absorption & Atomic Fluorescence Spectrometry

Atomic Absorption Spectroscopy

Chem 434 Instrumental Analysis Test 1

Ch. 8 Introduction to Optical Atomic Spectroscopy

Lecture 7: Atomic Spectroscopy

Chem 155 Quiz 3 Review Topics: Quiz 3 outline

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

SELİN CANSU ÖZTÜRK ŞEYMA ATAKUL SEZİN GÜNER

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Partial Energy Level Diagrams

CHAPTER 8 Introduction to Optical Atomic Spectrometry

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

INTRODUCTION TO OPTICAL ATOMIC SPECTROSCOPY (Chapter 8)

II. Spectrophotometry (Chapters 17, 19, 20)

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Atomic Emission Spectroscopy

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Chemistry Instrumental Analysis Lecture 17. Chem 4631

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Atomic absorption spectroscopy

Lecture No. 4. i 0 TETA I RY:

Chapter 8: Introduction to Atomic Spectrometry

Introduction to Spectroscopic methods

1. Cyclic voltammetry involves the measurement of a diffusion controlled at an electrode in which the is controlled. (4 points)

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chem 434 -Instrumental Analysis Hour Exam 1

COMPARISON OF ATOMIZERS

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

A Spectrophotometric Analysis of Calcium in Cereal

Chemistry 311: Topic 2 - Atomic Spectroscopy Topic 2: Spectroscopy:

FLAME PHOTOMETRY AIM INTRODUCTION

Ionization Techniques Part IV

Spectroscopy Problem Set February 22, 2018

Ch 313 FINAL EXAM OUTLINE Spring 2010

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

PRINCIPLE OF ICP- AES

Atomic Absorption Spectrometer ZEEnit P series

Prof. Dr. Biljana Škrbić, Jelena Živančev

a. An emission line as close as possible to the analyte resonance line

Topic 3: Periodic Trends and Atomic Spectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

Questions on Instrumental Methods of Analysis

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

FTIR measurement of NH 3, HCN, SO 2, H 2 S and COS in pulverized lignite oxy-fuel flames Daniel Fleig, Stefan Hjärtstam and Daniel Kühnemuth

Light Emission. Today s Topics. Excitation/De-Excitation 10/26/2008. Excitation Emission Spectra Incandescence

Application of IR Raman Spectroscopy

novaa 800 D Atomic Absorption Spectrometer

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Atomic Spectroscopy AA/ICP/ICPMS:

Sample Copyright. Academic Group ATOMIC STRUCTURE 1. Topics covered in this chapter:

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Analytical Topics to Consider in preparation for the MFAT/GRE

Wavelength Frequency Measurements

2. Discrete means unique, that other states don t overlap it. 3. Electrons in the outer electron shells have greater potential energy.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Two-electron systems

Molecular Luminescence Spectroscopy

Chemistry Instrumental Analysis Lecture 3. Chem 4631

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Final Exam. Physical Constants and Conversion Factors. Equations

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Instrumental Analysis

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

Chem 310 rd. 3 Homework Set Answers

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008

Chem 321 Name Answer Key D. Miller

Lecture 6. Rapid Thermal Processing. Reading: Chapter 6

2014 학년도 1 학기 분석화학실험. 담당교수 : 이원용 ( 연구실 : 과 443-C, 전화 : , 전자우편 : 분광분석 / / 분리분석 / 전기분석화학

Cork Institute of Technology. Summer 2005 Instrumental Analysis (Time: 3 Hours) Section A

Electron temperature is the temperature that describes, through Maxwell's law, the kinetic energy distribution of the free electrons.

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Transcription:

Atomic Absorption Spectrometry (Chapter 9) AAS intrinsically more sensitive than AES similar atomization techniques to AES addition of radiation source high temperature for atomization necessary flame and electrothermal atomization very high temperature for excitation not necessary generally no plasma/arc/spark AAS CEM 333 page 9.1

Flame AAS: simplest atomization of gas/solution/solid laminar flow burner - stable "sheet" of flame flame atomization best for reproducibility (precision) (<1%) relatively insensitive - incomplete volatilization, short time in beam Fig 9-3 Primary combustion zone - initial decomposition, molecular fragments, cool Interzonal region - hottest, most atomic fragments, used for emission/fluorescence Secondary combustion zone - cooler, conversion of atoms to stable molecules, oxides CEM 333 page 9.2

element rapidly oxidizes - largest [atom] near burner element poorly oxidizes - largest [atom] away from burner most sensitive part of flame for AAS varies with analyte Consequences? sensitivity varies with element must maximize burner position makes multielement detection difficult Fig 9-4 CEM 333 page 9.3

Electrothermal Atomizers: entire sample atomized short time (2000-3000 C) sample spends up to 1 s in analysis volume superior sensitivity (10-10-10-13 g analyte) less reproducible (5-10 %) Graphite furnace ETA (Fig 9-6) external Ar gas prevents tube destruction internal Ar gas circulates gaseous analyte CEM 333 page 9.4

Three step sample preparation for graphite furnace: (1) Dry - evaporation of solvents (10->100 s) (2) Ash - removal of volatile hydroxides, sulfates, carbonates (10-100 s) (3) Fire/Atomize - atomization of remaining analyte (1 s) Fig 9-7 CEM 333 page 9.5

Atomic Absorption Instrumentation: AAS should be very selective - each element has different set of energy levels and lines very narrow BUT for linear calibration curve (Beers' Law) need bandwidth of absorbing species to be broader than that of light source difficult with ordinary monochromator Solved by using very narrow line radiation sources minimize Doppler broadening pressure broadening lower P and T than atomizer and using resonant absorption Na emission 3p 2s at 589.6 nm used to probe Na in analyte CEM 333 page 9.6

Hollow Cathode Lamp: (Fig 9-11) 300 V applied between anode (+) and metal cathode (-) Ar ions bombard cathode and sputter cathode atoms Fraction of sputtered atoms excited, then fluoresce Cathode made of metal of interest (Na, Ca, K, Fe...) different lamp for each element restricts multielement detection Hollow cathode to maximize probability of redeposition on cathode restricts light direction CEM 333 page 9.7

Electrodeless Discharge Lamp: (Fig 9-12) CEM 333 page 9.8

AAS Spectrophotometers: Fig 9-13(a) Signal at one wavelength often contains luminescence from interferents in flame Chemical interference: (i) reverses atomization equilibria (ii) reacts with analyte to form low volatility compound releasing agent - cations that react preferentially with interferent - Sr acts as releasing agent for Ca with phosphate protecting agent - form stable but volatile compounds with analyte (metal-edta formation constants) CEM 333 page 9.9

(iii) ionization M M + + e E = IP M N M + = N M exp IP M kt hotter atomization means: more ionization emission from interferents CEM 333 page 9.10

Spectral interference - emission or absorption from interferent overlaps analyte Fig 9-13(b) Beam usually chopped or modulated at known frequency Signal then contains constant (background) and dynamic (timevarying) signals CEM 333 page 9.11

Light Intensity No analyte Lamp off No analyte Lamp on Analyte Lamp on emission from flame emission from lamp absorbed by analyte Ref Flame Ref Flame Ref Flame Time CEM 333 page 9.12

Detection limits for AAS/AES? AA/AE comparable (ppb in flame) AAS less suitable for weak absorbers (forbidden transitions) metalloids and non-metals (absorb in UV) metals with low IP (alkali metals) CEM 333 page 9.13