Title Process of Ethanol in Activated Car. Citation Physics Procedia (2015), 69:

Similar documents
Project Research. Project 2

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS OF KUR FUEL ASSEMBLY DURING LOSS OF COOLANT ACCIDENT

Y.; Kobayashi, H.; Inatani, Y. Citation Physics Procedia (2015), 67: Right article under the CC BY-NC-ND

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Evaluation of the Characteristic of Adsorption in a Double-Effect Adsorption Chiller with FAM-Z01

A Novel Model Considered Mass and Energy Conservation for Both Liquid and Vapor in Adsorption Refrigeration System.

An Experimental Study On Condensation Of R134a In A Multi-Port Extruded Tube

Available online at ScienceDirect. Physics Procedia 69 (2015 )

Author(s) Tatsuzawa, Ryotaro; Takaki, Naoyuki. Citation Physics Procedia (2015), 64:

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

If there is convective heat transfer from outer surface to fluid maintained at T W.

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Performance test of a G-M cooler in magnetic field

Neutronic studies on a pulsed thermal neutron source based on the Be(p,n) reaction by using a compact proton accelerator

Evaluation of Performance of Thermal and Electrical Hybrid Adsorption Chiller Cycles with Mechanical Booster Pumps

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 157 (2016 )

ScienceDirect. Buoyancy driven turbulence of moist air

Performance investigation of a waste heat driven pressurized adsorption refrigeration cycle

Two-Phase Refrigerant Distribution in a Micro- Channel Manifold

Available online at ScienceDirect. Energy Procedia 75 (2015 )

An experimental investigation of the thermal performance of an asymmetrical at plate heat pipe

SEPARATION BY BARRIER

Title Neutron Beam at J-PARC/MLF/BL09. Kino, Koichi; Yonemura, Masao; Kiya. Citation Physics Procedia (2015), 69:

Experimental study of CO 2 releases from a saturated liquid reservoir

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

Author(s) Atsushi; Urayama, Shinichi; Fukuyam. Citation Physics Procedia (2015), 65:

Complex Compounds Background of Complex Compound Technology

III E

Available online at ScienceDirect. Nuclear power plant explosions at Fukushima-Daiichi. Takashi Tsuruda*

Principles of Solar Thermal Conversion

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

ECHE Questions Centrifugal Pumps

Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Modeling, Simulation and Optimization of the Mechanical Response of Micromechanical Silicon Cantilever: Application to Piezoresistive Force Sensor

(ii) the total kinetic energy of the gas molecules (1 mark) (iii) the total potential energy of the gas molecules (1 mark)

EXECUTIVE SUMMARY. especially in last 50 years. Industries, especially power industry, are the large anthropogenic

Put sufficient ice cubes into water (1 M) and wait for equilibrium (both exist) (1 M)

Numerical Simulation of H 2 O/LiBr Falling Film Absorption Process

Study of the performance of activated carbon methanol adsorption systems concerning heat and mass transfer

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

ScienceDirect. Finite element analysis and optimization of flexure bearing for linear motor compressor

Supplemental Information. Storage and Recycling of Interfacial. Solar Steam Enthalpy

HEAT TRANSFER 1 INTRODUCTION AND BASIC CONCEPTS 5 2 CONDUCTION

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

Supporting Information High Activity and Selectivity of Ag/SiO 2 Catalyst for Hydrogenation of Dimethyloxalate

Thermochimica Acta 518 (2011) Contents lists available at ScienceDirect. Thermochimica Acta. journal homepage:

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

Effects of Water Vapor on Tritium Release Behavior from Solid Breeder Materials

Polonium Behavior in eutectic Lead Bismuth Alloy

Available online at ScienceDirect. Energy Procedia 57 (2014 ) ISES Solar World Congress

Density Field Measurement by Digital Laser Speckle Photography

An open sorption heat storage concept and materials for building heat supply

Pulsating heat pipe panels

Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

A dynamic model of a vertical direct expansion ground heat exchanger

Available online at ScienceDirect. Energy Procedia 71 (2015 )

Batch production of YBCO disks for levitation applications.

Determination of single-particle drying kinetics in an acoustic levitator

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

QUANTIFICATION OF WATER PENETRATION INTO CONCRETE THROUGH CRACKS BY NEUTRON RADIOGRAPHY

Using sand and other small grained materials as heat storage medium in a packed bed HTTESS

Heat Transfer Characteristics of Square Micro Pin Fins under Natural Convection

Characteristics of CO2 Transcritical Expansion Process

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

A thermodynamic system is taken from an initial state X along the path XYZX as shown in the PV-diagram.

ERT 216 HEAT & MASS TRANSFER SEM2, 2013/2014

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Homework - Lecture 11.

Available online at ScienceDirect. Procedia Engineering 157 (2016 ) 44 49

Vacuum techniques (down to 1 K)

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

DIRECT MEASUREMENT OF IN-SITU WATER SATURATION IN THE GEYSERS ROCK

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Adsorption of Polar and Nonpolar Vapors on Selected Adsorbents: Breakthrough Curves and their Simulation

2. Modeling of shrinkage during first drying period

Rapid Catalyst Screening Reactors

PHYS102 Previous Exam Problems. Temperature, Heat & The First Law of Thermodynamics

Fig.8-1 Scheme of the fluidization column

Per 5 Activity Solutions: Thermal Energy, the Microscopic Picture

A Review on Performance Improvement of Adsorber Bed by Effective Heating and Cooling

Answer: Volume of water heated = 3.0 litre per minute Mass of water heated, m = 3000 g per minute Increase in temperature,

Available online at ScienceDirect. Energy Procedia 74 (2015 )

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

THERMODYNAMICS. Chapter Twelve MCQ I

Particle Image Velocimetry Investigations of Turbulence in Superfluid Helium. S. W. Van Sciver

Australian Journal of Basic and Applied Sciences. Numerical Investigation of Flow Boiling in Double-Layer Microchannel Heat Sink

Biochemistry. Biochemical Techniques HPLC

Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Available online at ScienceDirect. Procedia Engineering 106 (2015 ) Dynamics and Vibroacoustics of Machines (DVM2014)

CHARACTERISATION OF SEGREGATION BY DYNAMIC NEUTRON RADIOGRAPHY

A generic adsorption heat pump model for system simulations in TRNSYS

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Mass Transfer Lab

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

An experimental investigation on condensation of R134a refrigerant in microchannel heat exchanger

Recap: Introduction 12/1/2015. EVE 402 Air Pollution Generation and Control. Adsorption

Transcription:

Title Visualization and Measurement of Ad Process of Ethanol in Activated Car Author(s) Asano, Hitoshi; Murata, Kenta; Take Yasushi Citation Physics Procedia (2015), 69: 503-50 Issue Date 2015 URL http://hdl.handle.net/2433/216137 2015 The Authors. Published by El open-access article distributed und RightCommons Attribution Non-Commercial nc-nd) License <http://creativecomm nd/4.0/>. Type Journal Article Textversion publisher Kyoto University

Available online at www.sciencedirect.com ScienceDirect Physics Procedia 69 (2015 ) 503 508 10th World Conference on Neutron Radiography 5-10 October 2014 Visualization and Measurement of Adsorption/Desorption Process of Ethanol in Activated Carbon Adsorber Hitoshi Asano a, *, Kenta Murata a, Nobuyuki Takenaka a, Yasushi Saito b a Department of Mechanical Engineering, Kobe University, 1-1, Rokkodai, Nada, Kobe 657-8501, Japan, b Kyoto University Research Reactor Institute, 2 Asashiro-Nishi, Kumatori, Osaka 590-0494, Japan Abstract Adsorption refrigerator is one of the efficient tools for waste heat recovery, because the system is driven by heat at relative low temperature. However, the coefficient of performance is low due to its batch operation and the heat capacity of the adsorber. In order to improve the performance, it is important to optimize the configuration to minimize the amount of driving heat, and to clarify adsorption/desorption phenomena in transient conditions. Neutron radiography was applied to visualize and measure the adsorption amount distribution in an adsorber. The visualization experiments had been performed at the neutron radiography facility of E-2 port of Kyoto University Research Reactor. Activated carbon and ethanol were used as the adsorbent and refrigerant. From the acquired radiographs, adsorption amount was quantitatively measured by applying the umbra method using a checkered neutron absorber with boron powder. Then, transient adsorption and desorption processes of a rectangular adsorber with 84 mm in width, 50 mm in height and 20 mm in depth were visualized. As the result, the effect of fins in the adsorbent layer on the adsorption amount distribution was clearly visualized. 2015 The Authors. Published by Elsevier by Elsevier B.V. B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Selection and peer-review under responsibility of Paul Scherrer Institut. Selection and peer-review under responsibility of Paul Scherrer Institut Keywords: Adsorption, Nondistructive measurement, Activated carbon, Ethanol, Neutron radiography 1. Introduction An adsorption refrigerating system is expected to be one of the efficient tools for waste heat recovery, because the system can be driven by heat at relative low temperature. The operation of an adsorption refrigerator is * Corresponding author. Tel.: +81-78-803-6122; fax: +81-78-803-6122. E-mail address: asano@mech.kobe-u.ac.jp 1875-3892 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Selection and peer-review under responsibility of Paul Scherrer Institut doi:10.1016/j.phpro.2015.07.071

504 Hitoshi Asano et al. / Physics Procedia 69 ( 2015 ) 503 508 explained with Fig. 1. The evaporative pressure is kept low by adsorbing vapor into the adsorber. Since adsorbed amount in equilibrium increase with decreasing the temperature, and condensation heat is released in adsorption process, the adsorbent should be cooled to keep the adsorption performance. After the adsorption process, the adsorber is connected to a condenser by a valve switching. Then, the vapor is regenerated by heating of the adsorbent. The input heat is used for temperature rise of the adsorbent and the container, and is also used for the vaporization heat of refrigerant. The important point to improve the coefficient of performance is to enhance heat diffusion in the adsorption bed. Metallic fins or high thermal conductive fivers are often installed in adsorbent bed to enhance the heat diffusion. However, since an increase in heat capacity of the adsorber leads to a lowering of the coefficient of performance due to its batch operation, the configuration of adsorber must be optimized to minimize the amount of driving heat. On the other hand, higher bulk density of adsorbent will lead to higher heat diffusion. However, higher bulk density means smaller porosity and causes larger flow resistance of vapor. The fact will lead to a decrease in adsorption rate. Therefore, it is required for the optimization of the structure of adsorber to know the distribution of adsorbed refrigerant inside the adsorbent bed during adsorption or desorption. Numerical simulation models had been constructed by Kariya, et al. (2007), Zhao, et al. (2012), and Yang (2009). These models are based on some assumptions, for example, a homogenous distribution of adsorbent particles and a constant heat resistance between metallic wall and adsorbent particles. Measurement of adsorbed refrigerant distribution inside an adsorbent bed during transient process is required not only for the understanding of the phenomena but also for the benchmark data for such numerical simulation model. Neutron radiography is very effective to visualize fluid with hydrogen in a solid material, since the attenuation coefficient of neutron beam for hydrogen is higher than that for many other materials. For example, the attenuation coefficient for and ethanol is quite higher than aluminum, copper, and iron. Asano, et al. (2005, 2007) had carried out visualization experiments for hygroscopic distribution in silica gel particle bed. Wet particles were packed in an aluminum cylinder, then transient distributions in desorption process with heating was successfully visualized. A cylindrical adsorption unit cell using silica gel particles could be successfully visualized by neutron radiography. Cross-sectional distributions could be measured from multidirectional projection image by a CT method. In this study, adsorbed refrigerant distributions in an adsorbent bed were visualized by Neutron radiography for activated carbon powder and ethanol pair adsorber. Amount of adsorbed ethanol inside adsorbent in a rectangular container with aluminum fins was quantitatively measured by applying the umbra method using a checked neutron adsorber during transient adsorption or desorption process. 2. Quantitative measurement by the umbra method The experiments were performed in the neutron radiography facility at the E2 port of Kyoto University Research Reactor. Attenuated neutron beam was converted to optical image on the scintillation convertor, and the image was taken by a cooled CCD camera with 4008 2672 image elements and 16 bit intensity level. The pixel size was 42 μm in this experiment. Assuming that the brightness of a visualized image is proportional to the beam intensity on a scintillation converter and neglecting the attenuation in the vapor refrigerant in the adsorption bed, the brightness of the adsorbent bed in a metallic container S(x, y, t) is expressed as S Hot Regenator Cooling Adsorber ( ) O( x, y, t) ( x y, t) = G( x, y) I ( x, y) exp ρ μ t ( x, y) ρ μ t ( x, y) ρ μ t ( x, y, t), 0 w m,w w Ad m,ad Ad r m,r r + Cooling Condenser Expansion valve Evaporator Chilled Fig.1 Schematic diagram of adsorption refrigerator. where G and O is the gain and offset of the imaging system, I 0 is the irradiated beam intensity, ρ, μ m, and t are density, mass attenuation coefficient, and thickness along the neutron beam, respectively. The subscripts of w, Ad,

Hitoshi Asano et al. / Physics Procedia 69 ( 2015 ) 503 508 505 and r mean the wall, adsorbent, and refrigerant, respectively. The offset is caused by neutron scattering, stray light in the camera system, and dark current of the camera. Therefore, the value must be affected by the condition of the object. In this study, the offset was measured by the umbra method proposed by Takenaka, et al. (2001). The validity of the method was confirmed from the measurements of liquid refrigerant and adsorbent steps with several thickness. The steps were made in aluminum container as shown in Fig. 2. In the measurement of adsorbent bed, the neutron radiographs were taken for the dry and equilibrium adsorption condition, and then adsorbed refrigerant thickness was calculated from the comparison between two radiographs. A checked B 4 C grid with 3 mm in the pitch was placed at the front of the object to obtain umbra of neutron beam. An example original radiograph of the step of adsorbent layer in the equilibrium adsorption condition with the checked grid is shown in Fig. 2. The offset at a visualized area was obtained by interpolation of the brightness at adjacent parts of umbra. Activated carbon powder and ethanol was used as the adsorbent and refrigerant, respectively. The measured values of ρμ mt are plotted against the thickness of liquid ethanol as shown in Fig. 3. Bold symbols show the compensated results by the umbra method. Since the density and mass attenuation coefficient is constant, the relation must be linear. It was confirmed that the mass attenuation coefficient of liquid ethanol could be measured by the umbra method, and the value was 3.86 cm 2 /g. For the adsorbent bed, it could be seen that the compensation was required for the quantitative measurement. Using the measured attenuation coefficient the amount of adsorbed refrigerant in equilibrium condition was calculated and compare with the experimentally measured values by El-Sharkawy, et al. (2009) as shown in Fig. 4. The measured values by neutron radiography were agreed well with the previous results. Ethanol Adsorbent Neutron beam thickness [mm] 1 2 3 4 5 6 2 5 10 15 20 B 4C grid Convertor Attenuation in ethanol ρ r μ m,r t r [-] 2.5 2.0 1.5 1.0 0.5 Compensated results by the umbra method Liquid ethanol Adsorption layer Calculated results by using dark current Adsorption layer 0 0 0.5 1.0 1.5 2.0 2.5 Thickness of ethanol liquid [cm] Thickness of adsorption layer [cm] Fig. 3 Attenuation characteristic of liquid ethanol and adsorbent bed. Fig. 2 Neutron radiograph of adsorbent step with checked B 4C grid, and the configuration. 3. Measurements of adsorption/desorption process Transient changes in distribution of adsorbed ethanol were visualized during the adsorption or desorption process. Schematic diagram of the experimental setup and the configuration of the adsorbent container are shown in Fig. 5 and Fig. 6, respectively. The container was connected to a liquid ethanol reservoir immersed in a temperature controlled. The vapor pressure was maintained Adsorption amount in equiribrium [g/cm 2 ] 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Adsorption amount measured by neutron radiography [g/cm 2 ] Fig. 4 Comparison in adsorption amount of liquid ethanol in activated carbon particle bed.

506 Hitoshi Asano et al. / Physics Procedia 69 (2015) 503 508 by the temperature. The container was Irradiation room made from aluminum. The inside depth was 20 mm. A channel was drilled in the bottom wall. The adsorbent bed could be Test section heated or cooled from the bottom wall. On Adsorbent Cooling the inner surface of the bottom wall, two /heating aluminum fins with 1 mm in thickness were Reservoir installed to enhance the heat diffusion in the adsorbent bed. The front and back walls were thin SUS plate with 0.5 mm in Neutron beam Vacuum pump thickness to avoid heat diffusion through the VG: Vacuum gauge walls. Temperatures were measured by the Constant temperature ǻp: Differential pressure transducer bath inserted thermocouples at four points shown in Fig. 6. Examples of visualized results are shown Fig. 5 Schematic diagram of experimental setup in Figs 7. Exposure time and pixel size was Vapor flow 30 seconds and 42 μm, respectively. The reservoir temperature and the cooling 84 TC temperature were set to 10 and 30 ºC for the Adsorbent x4 adsorption process, respectively. For the 23 36 23 desorption process, those were 20 and 80 ºC. TC TC 20 In the visualized images, the darker part 30 10 means higher adsorbed amount. The inside wall and fin surface are traced by thin solid lines. For the dry condition in Fig. 6 (a), the Cooling/heating Aluminum fins (t=1 mm) To the constant adsorbent could be clearly visualized. temperature bath Figure 6 (b) was taken in an adsorption process after 8 minutes from the start. Fig. 6 Configuration of the test section Adsorption amount was larger in the surface layer and around the fins and sidewalls (area A) due to the effective cooling, and was also larger in the area C around the thermocouples. Flow resistance of vapor might be lower along the insert thermocouples due to the larger porosity. On the other hand, adsorption amount in the (a) Dry condition (b) In adsorption process bottom area of the bed (area B) was smaller. (after 8 min from the start) The reason might be the existence of inert gas. In the desorption process, voids were observed on the bottom surface just after the start (area D in Fig. 7 (c), (i)). The voids might be caused by a strong vapor generation by heating. Then, the desorption progressed at a faster rate near the heat transfer surface (area E in Fig. 7 (c), (i)). (i) After 2 min from the start (ii) After 120 min from the start (c) Desorption process from the adsorption equilibrium. Fig. 7 Visualized images by neutron radiography.

Hitoshi Asano et al. / Physics Procedia 69 ( 2015 ) 503 508 507 Figure 8 shows a visualized image with the checked B 4 C neutron adsorber. The adsorber was placed at the front of the test section. Adsorption amount at the visualized section indicated as 1 to 4 were measured during an adsorption process. At the initial condition, the activated carbon was perfectly dry. Time variations of temperatures and adsorption amount are plotted in Fig. 9 (a) and (b), respectively. The adsorbent bed temperature immediately increased after the start, and reached 70 ºC due to the strong adsorption. Then, the adsorption temperature gradually decreased, and the adsorption amount gradually increased with decreasing the temperature. It could be seen that the adsorption process was dominated by heat diffusion in the adsorbent bed. Adsorption amount was larger at the part of 1, 3, and 4 near the heat transfer surface including the aluminum fin. 4. Conclusions The adsorbed ethanol distribution in the activated carbon particle bed during adsorption and desorption process could be successfully visualized by neutron radiography. It was confirmed that the adsorbed amount could be quantitatively measured from radiographs by applying the umbra method to correct neutron scattering effect. Acknowledgements We would like to acknowledge Kyoto University Research Reactor Institute for supporting this study. References 1 2 4 3 Fig. 8 Visualized image with checked B 4C grid. Adsorbed amount of ethanol ρ r t r [g/cm 2 ] Temperature [ ] 1 0.1 2 3 4 0 0 50 100 150 200 Elapsed time [min] - - 0.4 0.3 0.2 80 70 60 50 40 30 T w T cin T ad1 T ad2 (a) Adsorption amount T cout T ad3 T cin T cout T ad1 T ad2 T ad3 T w 20 0 50 100 150 200 Elapsed time [min] (b) Temperature Fig. 9 Transient change in adsorption amount and temperature during adsorption process.

508 Hitoshi Asano et al. / Physics Procedia 69 ( 2015 ) 503 508 Kariya, K, Kuwahara, K., Koyama, S., 2007, Numerical Analysis for Optimal Design of Fin and Tube Type Adsorber - Case of activated carbon fiber/ethanol pair -, Transaction of the JSRAE, 24(4), 485 494. (in Japanese) Takenaka, N., Asano, H., Fujii, T., Matsubayashi, M., 2001, A Method for Quantitative Measurement by Thermal Neutron Radiography, Nondestructive Testing and Evaluation, 16, 345 354. Yang, P.Z., 2009, Heat and Mass Transfer in Adsorbent Bed with Consideration of Non-Equilibrium Adsorption, Applied Thermal Engineering, 29, 3198 3203. Zhao, Y, Hu, E, Blazewicz, A., 2012, Dynamic Modelling of an Activated Carbon Methanol Adsorption Refrigeration Tube with Considerations of Interfacial Convection and Transient Pressure Process, Applied Energy, 95, 276 284.