Circuit Reliability Review

Similar documents
Debbie Lee, Communications and Public Affairs Officer. Update on Southern California Edison s Capital Improvement Projects

BVES Annual Reliability Public Presentation 2016 Performance

ELECTRIC SYSTEM RELIABILITY ANNUAL REPORT

DISTRIBUTION SYSTEM ELECTRIC INFRASTRUCTURE RELIABILITY PERFORMANCE INDICATORS

Report on Reliability of ComEd Electrical Service within Downers Grove. Prepared November 13, 2015

Southern California Edison ESRB-8 Report Regarding Pro-Active De-Energization Event December 29 to January 1, 2019

Report on Reliability of ComEd Electrical Service within Downers Grove. Prepared September 1, 2013

Review of. Florida s Investor-Owned Electric Utilities Service Reliability reports. State of Florida

Southern California Edison Wildfire Mitigation & Grid Resiliency

2013 December Ice Storm

Review of. Florida s Investor-Owned Electric Utilities Service Reliability reports. State of Florida

Review of Florida s Investor-Owned Electric Utilities Service Reliability Reports. September

Review of Florida s Investor-Owned Electric Utilities Service Reliability Reports. November

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9

West Hollywood General Plan

PUBLIC SAFETY POWER SHUTOFF POLICIES AND PROCEDURES

Risk Management of Storm Damage to Overhead Power Lines

Smart Grid Opportunities Being Pursued. Stephanie Hamilton Brookhaven National Laboratory June 5, 2013

URD Cable Fault Prediction Model

Peterborough Distribution Inc Ashburnham Drive, PO Box 4125, Station Main Peterborough ON K9J 6Z5

Exploring the Reliability of U.S. Electric Utilities

Transmission & Distribution Electrical Reliability 2007 Annual Report

IS YOUR BUSINESS PREPARED FOR A POWER OUTAGE?

2014 San Gabriel Valley Water Forum. October 2, 2014

Network Quality and Reliability of Supply

Public Disclosure Copy

Electric Distribution Storm Hardening Initiatives. Paul V. Stergiou Distribution Engineering October 14 th, 2015

Lake Lure Community Meeting with Duke Energy

2018 General Rate Case Rebuttal Testimony

Director, Operations Services, Met-Ed

Public Disclosure Copy

2016 HURRICANE SEASON PREPARATION. March 30, 2016

Resiliency of Power Grids After Earthquakes

ADVANCED METHODS FOR PREDICTION OF ANIMAL-RELATED OUTAGES IN OVERHEAD DISTRIBUTION SYSTEMS MIN GUI

Clearance around powerlines.

Reven ue Req u i remen t Ap pl icat ion 2004/05 and 2005/06. BC hydro m W. Volume 2. Appendix L. System Performance Indicators

Winter Ready DC District of Columbia Public Service Commission

Reducing Wildfire Risk through the Use of Advanced Electrical Waveform Monitoring and Analytics

Staging for Utility Personnel and Mutual Aid. 1. Hermine- Meeting dates were August 29th_31 st, 2016 and September 1st, 2016.

Network Quality and Reliability of Supply Code

P.O BOX 429, NUKU ALOFA, Tel: (676) Fax: (676)

Big Data Paradigm for Risk- Based Predictive Asset and Outage Management

(U 338-E) Application of SCE Requesting Approval of its Grid Safety and Resiliency Program and Associated Ratemaking Mechanisms A.

BEFORE THE CORPORATION COMMISSION OF OKLAHOMA

Exploring the Reliability of U.S. Electric Utilities. Laboratory

How Power is Restored After a Severe Storm. Presented by Stacy Shaw, Safety Director & Nolan Hartzler, GIS Mapping Technician

Winter Preparation for Severe Weather Events

OPALCO Outage Analysis. December 2017 Board Meeting

Reliability Indices Measurement Reliability Indices Measurement for three 11 kv and 66 kv substations in Brunei Darussalam (PWR 01)

How Graphic Representations of Outages at Alabama Power Are Made Simple

QuantumWeather. A weather based decision support system for the utility industry. Bob Pasken and Bill Dannevik Saint Louis University

Estimating the Spatial Distribution of Power Outages during Hurricanes for Risk Management

Minnesota Public Utilities Commission Staff Briefing Papers

Major Event Response Reporting Guelph Hydro Electric Systems Inc. (Guelph Hydro) May 4, 2018 Wind Storm

An Introduction to Insulation Resistance Testing

COMMENT CARD RESPONSES (SEISMIC)

MULTI-AGENCY COORDINATION SYSTEM PUBLICATION CALIFORNIA FIRE WEATHER PROGRAM RISK PREPAREDNESS GUIDE MACS 410-3

Pu66ic Service Commission Of West Virginia

Superstorm Sandy What Risk Managers and Underwriters Learned

Powder River Basin Coal Update

f<~~ ~ Gulf Power April16, 2018

Power System Research Group Electrical Engineering Dept., University of Saskatchewan Saskatoon, Canada

Vegetation Related Transmission Outage Report

Responders Organized for Pass Emergencies (ROPE)

AUSLEY MCMULLEN ATTORNEYS AND COUNSELORS AT LAW 123 SOUTH CALHOUN STREET. P.O. BOX 391 (zip 32302) TALLAHASSEE, FLORIDA 32301

Deep Thunder. Local Area Precision Forecasting for Weather-Sensitive Business Operations (e.g. Electric Utility)

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA PACIFICORP. Direct Testimony of Heidemarie C. Caswell

Outage Coordination and Business Practices

2018 Annual Review of Availability Assessment Hours

OC Public Works El Niño Storm Preparation 2015

2014 Russell County Hazard Mitigation Plan Update STAKEHOLDERS AND TECHNICAL ADVISORS MEETING 2/6/14

Damage and Restoration of Drinking Water Systems Caused by 0206 Tainan Earthquake and Future Mitigation Measures

STORM IMPLEMENTATION PLAN & ANNUAL RELIABILITY PERFORMANCE REPORTS

A new FMECA model for reliability computations in electrical distribution systems

February Industry Communique

New Orleans has been Kept in the Dark Making Sense of Outages, Reliability, & Resilience

Lightning Density in Mid- South Synergy Service Territory

Implementation Status & Results Ethiopia Electricity Network Reinforcement and Expansion Project (ENREP) (P119893)

SDG&E Meteorology. EDO Major Projects. Electric Distribution Operations

Report on the U.S. NLDN System-wide Upgrade. Vaisala's U.S. National Lightning Detection Network

Research Article RELIABILITY ASSESSMENT OF RADIAL NETWORKS VIA MODIFIED RBD ANALYTICAL TECHNIQUE

By David & Debbie Hibbert

ICE STORM! a mini tabletop exercise for home care agencies

Storm Damage Modeling at the University of Connecticut

Renewables and the Smart Grid. Trip Doggett President & CEO Electric Reliability Council of Texas

Supplemental Material Table 1

SUBJECT: Adjustments to Photovoltaic and Electric Vehicle Forecasts to be Used in Southern California Edison Company's Distribution Planning

Entropy Minimization & Locating. Faults Across the Electrical Network. Using Customer No Light Calls

GIS Solution For Electric Utilities With Integration With Distribution Management System

About Nnergix +2, More than 2,5 GW forecasted. Forecasting in 5 countries. 4 predictive technologies. More than power facilities

Risk Analysis for Assessment of Vegetation Impact on Outages in Electric Power Systems. T. DOKIC, P.-C. CHEN, M. KEZUNOVIC Texas A&M University USA

DRAFT IEEE PES Winter Technical Meeting 2008 San Antonio, Texas Meeting Minutes

EVALUATION OF TSUNAMI RISK FOR COASTAL SOUTHERN CALIFORNIA CITIES. Appendix A - Figures

Superconducting Fault Current Limiters

RESILIENCE: THE NEW REALITY JEFFREY D. KNUEPPEL DEPUTY GENERAL MANAGER MARCH 17, 2015

ReCAP Status Review of the Updated Rural Access Index (RAI) Stephen Vincent, Principal Investigator

COMMUNITY DEVELOPMENT DEPARTMENT POLICY & PROCEDURE

S. S A N T A M O N I C A B L V D. B E V E R L Y H I L L S, C A

MACHINE LEARNING METHODS FOR THE ESTIMATION OF WEATHER AND ANIMAL-RELATED POWER OUTAGES ON OVERHEAD DISTRIBUTION FEEDERS PADMAVATHY KANKANALA

NEWS RELEASE. Province boosts winter highway safety measures

Transcription:

Circuit Reliability Review Marina Del Rey January 2018

Building a Smarter Grid for Southern California Southern California Edison is developing an electric grid to support California s transition to a clean and sustainable future that meets the needs and expectations of our customers. We are investing more than $13 billion in the power distribution grid over three years (2017-19). Our main investment goal is to increase power reliability through significant upgrades. The investments include: Upgrading cables, poles, switches and transformers Updating the grid so it can accommodate new technologies, such as smart inverters that will allow for the twoway flow of solar energy Adapting the power system to accommodate future California policy related to energy storage, electric transportation and renewable energy Providing enhanced automation and monitoring devices to allow us to better respond to changes on the grid Our investments in local communities will help ensure that customers receive safe, reliable, and affordable electricity now and in the future. Learn more at edison.com/innovation 2

Understanding Your Reliability Report As your electric utility, we want you to always have power when you need it. To get there, we constantly track and monitor electric outages across our service territory, and we measure our system reliability from this data. The two metrics we rely on are common in the electric utility industry: the System Average Interruption Duration Index (SAIDI) and the System Average Interruption Frequency Index (SAIFI). Both are described in more detail on the next page. Replacing and upgrading our infrastructure will help SCE maintain or improve SAIDI and SAIFI measurements. This report provides historical reliability data for the circuits that serve your jurisdiction and our proposed infrastructure upgrades for the current year. To view other reliability reports, visit sce.com>outage Center>Maintaining Reliable Service 3

Reliability Metrics MOMENTARY OUTAGES: OUTAGES LASTING 5 MINUTES OR LESS SUSTAINED OUTAGES: OUTAGES LASTING LONGER THAN 5 MINUTES MAIFI: o The number of times the average customer is interrupted by Momentary outages each year. SAIFI: o The number of times the average customer is interrupted by Sustained outages each year. SAIDI: o The cumulative amount of time the average customer is interrupted by Sustained outages each year. 4

Cities in the SANTA MONICA District CityList1 BEVERLY HILLS CULVER CITY FRANKLIN CANYON LADERA HEIGHTS LOS ANGELES MARINA DEL REY SANTA MONICA UNIVERSAL CITY WEST HOLLYWOOD 5

* Exclusions are days which utilities are allowed to remove from their metrics because the outages on those days were caused by a severe acts of nature. **In the columns showing Rank, lower numbers indicate poorer performance. 6

Overview of Marina Del Rey CircuitList1 There are 4 circuits that serve Marina Del Rey 1 Circuit Type Customers Circuit Type Customers Circuit Type Customers Circuit Type Customers BARNACLE(16KV) 68 - - - FANTAIL(16KV) 4,467 - - - SANDMAN(16KV) 1,289 - - - SEAHORSE(16KV) 291 - - - Grand Total 6,115 7

Reliability History of Circuits Serving Marina Del Rey (No Exclusions) BarChart 2014 2015 2016 2017 500.0 447.5 400.0 SAIDI (average minutes of sustained interruptions) 300.0 200.0 100.0 128.9 196.2 112.1 114.8 134.5 139.7 83.2 Marina Del Rey 0.0 2.5 2.0 2.3 SCE SYSTEMWIDE SAIFI (average frequency of sustained interruptions) 1.5 1.0 0.5 0.6 1.0 1.0 0.9 1.1 0.9 1.2 0.0 ** Exclusions are days which utilities are allowed to MAIFI (average frequency of momentary interruptions) 2.0 1.5 1.0 0.5 0.0 1.4 1.4 0.0 0.0 1.3 1.6 0.0 1.8 remove from their metrics because the outages on those days were caused by acts of nature. **Data is as of 02/20/2018, data can be slightly different due to outage data validation process 8

Causes of Repair Outages in Marina Del Rey 2017 SAIDIChart Vegetation /Animal 0.0% Other 0.0% Weather /Fire /Earthquake 0.0% Contributions to SAIDI by Outage Cause 3rd Party 0.0% Equipment Failure e.g., in-service failure of transformer, switch, or conductors Vegetation/Animal e.g., tree branch, rodent, or bird causing a short circuit between conductors Other e.g., patrolled but no cause found Operations e.g., urgent maintenance w/o 3-day notice 3 rd Party e.g., balloon, car hit pole, dig-in Operation 23.4% Equipment Failure 76.6% 3rd Party Equipment Failure Operation Other Vegetation /Animal Weather /Fire /Earthquake SAIDI = the cumulative amount of time the average customer is interrupted by sustained outages each year. 9

Causes of Repair Outages in Marina Del Rey 2017 SAIFIChart Vegetation /Animal 0.0% Other 0.0% Weather /Fire /Earthquake 0.0% Contributions to SAIFI by Outage Cause 3rd Party 0.0% Equipment Failure e.g., in-service failure of transformer, switch, or conductors Vegetation/Animal e.g., tree branch, rodent, or bird causing a short circuit between conductors Other e.g., patrolled but no cause found Operations e.g., urgent maintenance w/o 3-day notice 3 rd Party e.g., balloon, car hit pole, dig-in Operation 16.4% Equipment Failure 83.6% 3rd Party Equipment Failure Operation Other Vegetation /Animal Weather /Fire /Earthquake SAIFI = the number of times the average customer is interrupted by sustained outages each year 10

11

12

Back-up Slides Reliability Histories of Circuits Serving Marina Del Rey Updated through Dec 2017

Average Reliability of 4 Circuits Serving Marina Del Rey CitySummary 2014 2015 2016 1st Qtr 2017 2nd Qtr 2017 3rd Qtr 2017 4th Qtr 2017 2017 SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI 4 Circuits Serving Marina Del Rey -- Total Customers: 6,115 128.9 0.6-196.2 1.0-447.5 2.3 1.3 36.8 0.1-38.7 0.7 7.7 0.1-83.2 0.9-3rd Party Equipment Failure 74% 73% - 85% 75% - 97% 97% 30% 70% 35% - 98% 98% - - - 77% 84% - Operation 26% 27% - 15% 25% - 3% 3% 16% 30% 65% - 2% 2% 100% 100% - 23% 16% - Other 55% - - - Vegetation/Animal Weather/Fire/Earthquake SCE SYSTEMWIDE 112.1 1.0 1.4 114.8 0.9 1.4 134.5 1.1 1.6 42.6 0.3 0.5 23.6 0.2 0.4 29.2 0.2 0.4 44.3 0.4 0.5 139.7 1.2 1.8 Notes: No outages are excluded from the metrics. Outage Causes: Other: e.g., patrolled but no cause could be found Operations: e.g., urgent maintenance w/o 3-day notice to customers 3 rd Party: e.g., balloons, car hit pole, dig-in Vegetation/Animal: e.g., tree branch, rodent, or bird causing short circuit across conductors SAIDI (minutes) = the cumulative amount of time the average customer is interrupted by sustained (longer than 5 minutes) outages. SAIFI (interruptions) = the number of times the average customer is interrupted by sustained outages. MAIFI (interruptions) = the number of times the average customer is interrupted by momentary " (lasting 5 minutes or less) outages. 14

Reliability Histories for Individual Circuits Serving Marina Del Rey - 1 of 1 2014 2015 2016 1st Qtr 2017 2nd Qtr 2017 3rd Qtr 2017 4th Qtr 2017 2017 SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI BARNACLE(16KV) - Customers: 68 1302.5 6.0 4.7 0.1 - - - CircuitHistory - 3rd Party - - - 1 - Equipment Failure 100% 99% - - Operation 0% 1% 100% 100% Other Vegetation/Animal Weather/Fire/Earthquake FANTAIL(16KV) - Customers: 4,467 46.3 0.2-266.1 1.3-608.7 3.1 1.5 50.4 0.1-53.0 1.0 10.5 0.1-113.9 1.3-3rd Party Equipment Failure - - - 85% 83% - 97% 97% 35% 70% 35% - 98% 98% - - - 77% 84% - Operation 100% 100% - 15% 17% - 3% 3% - 30% 65% - 2% 2% 100% 100% - 23% 16% - Other 65% - - - Vegetation/Animal Weather/Fire/Earthquake SANDMAN(16KV) - Customers: 1,289 6.3 0.3-4.9 0.5 - - - 1.0 - - - 3rd Party Equipment Failure Operation 100% 100% - 100% 100% - - - 100% - - - Other Vegetation/Animal Weather/Fire/Earthquake SEAHORSE(16KV) - Customers: 291 92.3 0.8 - - 3rd Party Equipment Failure 100% 100% - - Operation Other Vegetation/Animal Weather/Fire/Earthquake 15