Mathematical Segmentation of Grey Matter, White Matter

Similar documents
Physics of MR Image Acquisition

Computing Covariances for Mutual Information Co-registration.

Basic Pulse Sequences I Saturation & Inversion Recovery UCLA. Radiology

EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 9 Solutions. Due April 29th, 2013

Critical Values for the Test of Flatness of a Histogram Using the Bhattacharyya Measure.

NMR and MRI : an introduction

Part III: Sequences and Contrast

Tissue Characteristics Module Three

FREQUENCY SELECTIVE EXCITATION

Magnetic Resonance Imaging (MRI)

Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

BNG/ECE 487 FINAL (W16)

Outlines: (June 11, 1996) Instructor:

Basis of MRI Contrast

A Weighted Multivariate Gaussian Markov Model For Brain Lesion Segmentation

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

MRI in Review: Simple Steps to Cutting Edge Part I

7.3.A. The expression for signal recovery is similar to that derived under exercise 7.2 and is given by:

Basic Pulse Sequences II - Spin Echoes. TE=12ms TE=47ms TE=106ms TE=153ms UCLA. Radiology

Contrast Mechanisms in MRI. Michael Jay Schillaci

Background II. Signal-to-Noise Ratio (SNR) Pulse Sequences Sampling and Trajectories Parallel Imaging. B.Hargreaves - RAD 229.

Brain Lesion Segmentation: A Bayesian Weighted EM Approach

HY Ιατρική Απεικόνιση. Διδάσκων: Kώστας Μαριάς

Rochester Institute of Technology Rochester, New York. COLLEGE of Science Department of Chemistry. NEW (or REVISED) COURSE:

Spatially Invariant Classification of Tissues in MR Images

On Signal to Noise Ratio Tradeoffs in fmri

Diffusion Tensor Imaging (DTI) e Neurite Orientation Dispersion and Density Imaging (NODDI)

MRI Physics I: Spins, Excitation, Relaxation

Introductory MRI Physics

Field trip: Tuesday, Feb 5th

MR Advance Techniques. Flow Phenomena. Class I

BME I5000: Biomedical Imaging

Bayesian and Non-Bayesian Probabilistic Models for Image Analysis

NMR/MRI examination (8N080 / 3F240)

Apodization. Gibbs Artifact. Bioengineering 280A Principles of Biomedical Imaging. Fall Quarter 2013 MRI Lecture 5. rect(k x )

Suppression of Static Magnetic Field in Diffusion Measurements of Heterogeneous Materials

K-space. Spin-Warp Pulse Sequence. At each point in time, the received signal is the Fourier transform of the object s(t) = M( k x

Pulse Sequences: EPG and Simulations

It is important. It is important. MTR: Imaging Clinical Trials. Isn t t it obvious? then why do we ask the question?

Spin Echo Imaging Sequence

Basic MRI physics and Functional MRI

Lecture #7 In Vivo Water

Magnetization Preparation Sequences

Introduction to Magnetic Resonance Imaging (MRI) Pietro Gori

Lab 2: Magnetic Resonance Imaging

RADIOLOGIV TECHNOLOGY 4912 COMPREHENSEIVE REVIEW/MRI WORSHEET #1- PATIENT CARE AND SAFETY/PHYSICAL PRINCIPLES

Magnetic resonance imaging MRI

Can arterial spin labelling techniques quantify cerebral blood flow (CBF)?

Sketch of the MRI Device

MR Spectroscopy: The Physical Basis and Acquisition Strategies

Research Article Thalamus Segmentation from Diffusion Tensor Magnetic Resonance Imaging

Measuring the invisible using Quantitative Magnetic Resonance Imaging

Chapter 24 MRA and Flow quantification. Yongquan Ye, Ph.D. Assist. Prof. Radiology, SOM Wayne State University

Tissue Parametric Mapping:

Technical Improvements in Quantitative Susceptibility Mapping

MRI Homework. i. (0.5 pt each) Consider the following arrangements of bar magnets in a strong magnetic field.

Diffusion Tensor Imaging (DTI): An overview of key concepts

Introduction to Biomedical Imaging

When Bayesian Model Selection meets the Scientific Method.

Sequence Overview. Gradient Echo Spin Echo Magnetization Preparation Sampling and Trajectories Parallel Imaging. B.Hargreaves - RAD 229

MRS: IN VIVO SPECTROSCOPIC IMAGING MAIN POINTS

Rad Tech 4912 MRI Registry Review. Outline of the Registry Exam: Certification Fees

Chapter 14:Physics of Magnetic Resonance

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Effect of Bulk Tissue Motion on Quantitative Perfusion and Diffusion Magnetic Resonance Imaging *

Pulse Sequences: RARE and Simulations

ROCHESTER INSTITUTE OF TECHNOLOGY COURSE OUTLINE FORM COLLEGE OF SCIENCE. Chester F. Carlson Center for Imaging Science

Longitudinal growth analysis of early childhood brain using deformation based morphometry

Designing Information Devices and Systems I Spring 2018 Homework 13

DIFFUSION MAGNETIC RESONANCE IMAGING

Applications of Spin Echo and Gradient Echo: Diffusion and Susceptibility Contrast

The effect of different number of diffusion gradients on SNR of diffusion tensor-derived measurement maps

Biomedical Imaging Magnetic Resonance Imaging

Investigation of Multicomponent MRI Relaxation Data with Stochastic Contraction Fitting Algorithm

MRI Physics (Phys 352A)

BASIC MRI PHYSICS SPIN GYMNASTICS Don Plewes PhD, Walter Kucharczyk MD

EEG- Signal Processing

Relaxation times in nuclear magnetic resonance

Optimizing Phases of CPMG Pulse Sequence and Applying Exact Solution to Measure Relaxation Time

RAD229: Midterm Exam 2015/2016 October 19, Minutes. Please do not proceed to the next page until the exam begins.

SE Sequence: 90º, 180º RF Pulses, Readout Gradient e.g., 256 voxels in a row

Technical University of Denmark

A Localized Linearized ROF Model for Surface Denoising

MRI in Practice. Catherine Westbrook MSc, DCRR, CTC Senior Lecturer Anglia Polytechnic University Cambridge UK. John Talbot MSc, DCRR

2.1.1 A Brief History of NMR The conception of NMR sprouted after the Pauli s prediction of nuclear spin in

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging I. Prof. Dr. Lothar Schad.

Ordinary Least Squares and its applications

A Brief Introduction to Medical Imaging. Outline

3.8 Combining Spatial Enhancement Methods 137

Optimizing Saturation Recovery Measurements of the Longitudinal Relaxation Rate Under Time Constraints

COMP9444 Neural Networks and Deep Learning 11. Boltzmann Machines. COMP9444 c Alan Blair, 2017

Spatial encoding in Magnetic Resonance Imaging. Jean-Marie BONNY

Spatial encoding in Magnetic Resonance Imaging. Jean-Marie BONNY

Adaptive Segmentation of MRI data

Brain Phantoms for Ultra High Field MRI

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

The Simulation and Optimization of NMR Experiments Using a Liouville Space Method

HST 583 FUNCTIONAL MAGNETIC RESONANCE IMAGING DATA ANALYSIS AND ACQUISITION A REVIEW OF STATISTICS FOR FMRI DATA ANALYSIS

Measuring cerebral blood flow and other haemodynamic parameters using Arterial Spin Labelling MRI. David Thomas

G Medical Imaging. Outline 4/13/2012. Physics of Magnetic Resonance Imaging

Transcription:

Tina Memo No. 2000-006 Short Version published in: British Journal of Radiology, 74, 234-242, 2001. Mathematical Segmentation of Grey Matter, White Matter and Cerebral Spinal Fluid from MR image Pairs. N.A.Thacker, A.Jackson, X.P.Zhu and K.L.Li. Last updated 2 / 3 / 2000 Imaging Science and Biomedical Engineering Division, Medical School, University of Manchester, Stopford Building, Oxford Road, Manchester, M13 9PT.

Abstract There have been many approaches to grey and white matter measurement in NMR images [1, 2, 4, 5]. For clinical use the estimated values must be reliable and accurate. Unfortunately, many techniques fail on these criteria in an unrestricted clinical environment. A recent method for tissue quantification in NMR image analysis has the advantage of great simplicity, while at the same time taking account of partial volume effects [3]. This technique makes use of two imaging sequences to provide three linearly independent linear equations. We show that, although the original mathematical solution could still be used with a specific set of modern sequences, there are advantages to generalising the solution which give far more scope for application and greater accuracy. A theoretical analysis is presented here, which is backed up with real images. Background The quantities of CSF, grey matter and white matter (p c, p g and p w respectively) can be used to estimate each pixel grey level g, g 1 = p c G 1c + p g G 1g + p w G 1w and g 2 = p c G 2c + p g G 2g + p w G 2w where G 1c, G 1g and G 1w are the mean grey levels of pure tissue. These equations follow directly from the Bloch equations for the NMR imaging process for a wide range of sequences and together with the constraint that the total quantity of matter must be equal to the volume, ie: p c + p g + p w = 1 give enough information to solve for the three tissue quantities within any volume. Clearly the assumption that a pure tissue will give a constant signal response is a simplification in practice, particularly as field strength effects can produce position dependent sensitivity. Assuming that these effects can be appropriately removed we can go on to solve these equations to recover tissue proportions. The method presented in [3] used a particular imaging sequence to generates an image in which the average proportion of tissue P within a volume generate a contribution to the average grey level P g G 1g + P w G 1w which averages out to zero. The average value of G 1 within the volume can then be used directly to estimate P c. Given this and the other two equations, it is then a relatively easy matter to estimate P c and P w within the volume of V voxels. V P c = g1v /(G 1c V ) P g = G 2w V g 2v /V P c (G 2w G 2c ) G 2w G 2g P w = 1 P c P g The second image was chosen to give good contrast between grey and white matter in order to give good accuracy for this process. However, the first image was selected to simplify the solution of the linear system. Unfortunately, although this was a relatively recent publication, the suggested imaging sequence has generally been replaced in clinical situations by Turbo/Spin-Echo for reasons of speed. This paper addresses the issue of updating the method to make use of modern imaging sequences. Staying for a while within the solution framework adopted by Rusinek, can we find an imaging sequence for which the assumptions used in the solution will still hold, ie: is there a sequence for which the real signal intensity of the grey and white matter tissues produce grey level values which are approximately equal, opposite and small compared to CFS. The expression for the signal intensities of brain tissues in an inversion recovery spin-echo (IRSE) sequence follows directly from the Bloch equations and is where S = N(H)(1 2 exp( T I/T 1 ) + 2 exp( (T R τ)/t 1 ) exp( T R/T 1 ))exp( T E/T 2 ) τ = T E/2 where N(H) is the spin density and T E is the echo time. When this is plotted as a function of T I there is a point at which the signal for grey and white matter have equal and opposite values. This is the point selected 2

by Rusinek for one of his imaging sequences. The modern equivalent to (IRSE) is the inversion recovery turbo spin-echo (IRTSE) sequence. The expression for the signal intensities of brain tissues in an IRTSE sequence S = N(H)(1 2 exp( T I/T 1 ) + 2 exp( (T R T s N f )/T 1 ) exp( T R/T 1 ))exp( T E eff /T 2 ) where T s is echo spacing and N f is the factor number of the TSE train. The bloch equation has very similar form to that for IRSE and by careful selection of parameters we can achieve the same signal curves. We can use the same scan parameters (T E eff = T E) and on the assumption that N(H) is the same for grey and white matter we will get equal amplitudes but different sign at T I = 600ms. The longer time delays for short echo train TSE read-out causes little differences in T 1 weightings provided that long T R s are used ( T R > 4000ms ). However, it is well known that IRTSE has different contrast to conventional ITSE, in particular: there is more crosstalk between slices due to a shorter 180 o rf pulse. there is more noise due to the wider bandwidth long T 2 substance tends to be brighter because of averaging of later echoes. there is more magnetization transfer so that fat and grey matter are brighter on IRTSE images. these four are the most important effects here are those that tend to increase the noise in the image and in practice modern scanners can produce images which are comparable to those used in the original work. Methods In the table below we give the parameters for seven scanning sequences used here. Sequence TR(ms) TE(ms) TI(ms) TSE factor echo space (ms) CSF Grey White error IRSE (R1) 5000 100 490 7 25-1900 -100 100 60 IRSE (R2) 1400 30 425 3 15-500 -50 400 90 IRTSE 6850 18 300 9 18-1800 -650-200 60 VE (PD) 5500 20-8 13.3 1475 1270 970 80 VE (T2) 5500 100-8 13.3 1450 435 320 80 Flair 6000 100 2200 19 10 250 750 550 30 CSF 8000 250-45 10.9 2070 100 100 30 Table 1 Given the correct NMR images, Rusinek s method provides a straight-forward way of estimating tissue quantities in the brain. The calculation is simple and the method can be performed using a pocket calculator and some basic image display software, as the calculation is based upon mean grey levels within a region of interest. Unfortunately, it is not possible to generate pixel level partial volume probabilities, (ie: an image segmentation for visualisation), because the CSF measurement has to be averaged over a volume containing equal grey and white matter proportions for the assumption of grey and white matter cancellation to be valid. Any calculation performed at a particular pixel which contains mainly one tissue type will be biased. The general problem of cancellation may be quite common, as mean grey level values for nominally the same sequences can vary from machine to machine and due to brain disease. It is unfortunate that the technique is likely to give innacurate results for the very people for which an accurate measurement is most important. However, these problems can be eliminated, and pixel level segmentation can be achieved, if the assumption of grey matter/white matter cancellation is not made and the tri-linear equations solved (using accurate mean grey level values for each tissue) within each voxel v as follows: p cv = g 1v(G 2w G 2g ) g 2v (G 1w G 1g ) (G 1g G 2w G 2g G 1w ) (G 1c G 1g )(G 2w G 2g ) (G 2c G 2g )(G 1w G 1g ) p gv = g 1v(G 2c G 2w ) g 2v (G 1c G 1w ) (G 1w G 2c G 2w G 1c ) (G 1g G 1w )(G 2c G 2w ) (G 2g G 2w )(G 1c G 1w ) 3

and p wv = 1 p cv p gv The average proportion over the volume for tissue t is now given by P t = V v p tv/v. giving and P c = G 1(G 2w G 2g ) G 2 (G 1w G 1g )(G 1g G 2w G 2g G 1w ) (G 1c G 1g )(G 2w G 2g ) (G 2c G 2g )(G 1w G 1g ) P g = G 1(G 2c G 2w ) G 2 (G 1c G 1w )(G 1w G 2c G 2w G 1c ) (G 1g G 1w )(G 2c G 2w ) (G 2g G 2w )(G 1c G 1w ) P w = 1 P c P g These equations revert to the original solution if we make the assumption that G 1g = G 1w = 0. Once again these equations are based directly upon the property of linear additivity of tissue to the image signal, which follows directly from Bloch equations for a wide variety of NMR sequences. As this solution takes no account of the noise process during image formation it is possible for these solutions to take non-physical values ie: P i < 0 or P i > 1. These numbers cannot be interpreted directly as probabilities, though they are unbiased estimates of tissue proportion. This is the correct solution for any pair of NMR images for which the mean tissue grey levels are linearly independent and we can use this algorithm on any other images which satisfy the same constraint. This also opens up the possibility of using the method for any triplet of tissues, not just CSF, white matter and grey matter in brain images. Also, we are free to select any pair of images which might deliver the required partial volumes with the best statistical accuracy. As we will now show, these are unlikely to be those used in the original method. The process of NMR image formation contains several factors which can be modeled in a series of stages. The Bloch equations establish mean grey level values for particular tissues. Partial volume effects are modeled linearly, as in the assumptions for the derivation of the method described above. Finally there is the process of noise which perturbs the grey level values away from their nominal values. For the purposes of the following analysis we assume that the noise source can be modeled as the expected linearly weighted means plus a uniform measurement noise. This can be observed to be generally true for a wide range of NMR image sequences. Thus, the grey level that we observe in image i is given by g iv = g iv + n where n is a normally distributed random variable with characteristic width σ i. We can compute the expected accuracy on the calculation of p cv using these numbers; assuming that the mean grey level values are much more accurate than individual pixel measurements, it is possible to estimate the expected accuracy of per pixel partial volume measurement. δ cv = (G2w G 2g ) 2 σ 2 1 + (G 1w G 1g ) 2 σ 2 2 (G 1c G 1g )(G 2w G 2g ) (G 2c G 2g )(G 1w G 1g ) δ gv = (G2c G 2w ) 2 σ1 2 + (G 1c G 1w ) 2 σ2 2 (G 1g G 1w )(G 2c G 2w ) (G 2g G 2w )(G 1c G 1w ) δ wv = (G2c G 2g ) 2 σ 2 1 + (G 1c G 1g ) 2 σ 2 2 (G 1w G 1g )(G 2c G 2g ) (G 2w G 2g )(G 1c G 1g ) As the noise process in each voxel is independent of all others, the expected accuracy of the estimates P t for tissue t are given by t = δ t / V Thus the accuracy of proportion of tissue measurement increases as the square root of the measured volume. We are now in a position to evaluate the choice of image sequences in the standard Rusinek method. Assuming that the second image has been selected in order to give the best contrast between the three tissues, the question is: will the choice of a second image with G w = G g = 0 give the best statistical accuracy on the final estimates of tissue proportion? What is clear from the expressions for δ ct (and also the others) is that the best noise performance will be obtained when the numerator is as large as possible, while this choice of grey levels reduces the negative term to zero we can actually go further than this by inverting the order of G w and G g. Thus, the freedom to solve these equations without having to make the standard assumption gives us the potential of greater statistical accuracy. Although it is a difficult process to optimise this expression, to get the best possible accuracy from a physically valid pair of NMR images, we can show that the standard selection is not the best choice simply by finding an alternative pair of sequences for which the statistical accuracy of the technique would be greater. These sequences include the Turbo Spin collection equivalent of the images in the original work (IRSE (R1) and IRSE (R2), our own best estimate of a pure CSF image and a high contrast anotomical image (CSF and IRTSE), an image which inverts the tissue order (FLAIR) and finally a pair of variable echo sequences, purely because these 4

are commonly available in a clinical environment. The estimated grey level value for the three tissues, together with an estimate of the rms noise in these MRI image sequences, are given in Table 1. The calculated grey and white matter pixel accuracies (δ g and δ w ) are given in the following table; the upper diagonal is for grey matter and the lower diagonal is for white matter. Sequence IRSE (R1) IRSE (R2) IRTSE VE (PD) VE (T2) FLAIR CSF IRSE (R1) - 0.26 0.26 0.33-0.14 0.34 IRSE (R2) 0.23-0.49 1.99 0.31 0.12 0.20 IRTSE 0.22 0.34-0.52 0.45 0.11 0.14 VE (PD) 0.29 0.95 0.37-0.35 0.15 0.27 VE (T2) - 0.24 0.34 0.29-0.16 0.71 Flair 0.13 0.15 0.10 0.21 0.19-0.15 CSF 0.33 0.20 0.14 0.27 0.71 0.15 - Table 3 As can be seen, several combinations of images are predicted to be theoretically superior to the original pair. Best results are obtained when one of the combination is the FLAIR image sequence, due to the inversion of tissue grey level order. Though in practice this sequence may cause a problem due to flow artifacts, the next best alternative is the one we have called CSF. The grey matter volume, which is particularly important in monitoring development of degenerative diseases, can be a factor of 2.5 more accurate with some pairings of sequences. Interestingly, the standard variable echo pair would also seem to give quite a reasonable segmentation, even though these images have not been specifically designed for use in this way. Results We have tested the new pixel level classifiaction algorithm on scans from a normal subject. Firstly, we obtained data according to the original published technique 1(a) 1(b). Nominal tissue values were obtained by curve fitting the histogram of pixel intensities with a function composed of three Gaussian peaks with flat between peak components to account for partial volume effects. The image data was then processed using the new equations. We obtained pixel level probability images for grey matter and white matter 1(c) 1(d) masked in the area of the brain 1. The full solution for the set of equations now allows us to visualise the effects of improved accuracy and reduction of bias (typically 4 %) in a pixel level segmentation. We recreated the effect of assuming equal grey levels for grey matter and white matter in the original solution by setting the assumed grey level values for these tissues equal to the average 2. Note the bias in the original solution 2(a) 2(b) which is bi-modal due to the systematic dependency on tissue type which has a typical value of 4 %. The above analysis suggests that there are four pairs of images which are of interest. The turbo spin echo equivalent of the original Rusinek pair (IRSE (R1) and (R2) ), the pair with the best predicted accuracy (FLAIR and IRTSE), the next best combination excluding FLAR (IRTSE and CSF) and the variable echos (VE (PD) and VE(T2)). We analysed these images 1(e) and 1(f), 1(e) and 1(i), 1(l) and 1(m) computing once again the grey and white matter probability maps 1(g) 1(h) 1(j) 1(k) 1(n) 1(o). These maps have statistical errors which are consistent with our predicted values. The improvement in stability of probability estimation from the new sequences is plainly visible. A subtraction of corresponding probability maps from these two data sets shows that these estimates are consistent except for the improvement in statistical noise. Discussion and Conclusions The results and analysis presented here have concentrated mainly on the effects of bias and statistical error. One such effect is now visible in the probability map for white matter. There are some areas of white matter which have a systematically lower probability than others. Although these effects are also present in the solution from the first pair of images, it only becomes clearly visible once the noise level has been reduced. Such problems were discussed in the original work; however, in most situations, systematic effects do not hinder the effect of quantifying change. We have generalised a recent technique for estimating tissue proportions from NMR image sequences. The new technique is more powerful as it can be applied to any combination of NMR image pairs. Also this technique can be made more accurate than the original solution by careful selection of image sequences, using the freedom that this new solution provides. A pair of sequences has been found which gives a potential improvement of a factor of 1 The calclation for tissue types other than the three modelled is undefined 2 we have not assumed a zero value as this is not a good mean value for these tissues on our scanner 5

2.5 in accuracy of tissue volume measurement over the original technique. This has been illustrated graphically by a pixel level segmentation which is also made possible by the new approach. We believe that this work illustrates the importance of being able to select imaging protocols according to the requirements of processing algorithms. Though the image sequences we suggest are significantly better than those in the original publication we do not suggest that this is an optimal combination. However, the analysis technique outlined in this paper provides a framework for the comparison of other possible alternatives and shows that there is potentially much to be gained both in terms of accuracy, speed and utility by having the extra flexibility delivered by the new solution. (a) IRSE(R1) (b) IRSE(R2) (c) Grey matter (d) White Matter (e) IRTSE (f) FLAIR (g) Grey matter (h) White Matter (i) CSF (j) Grey matter (k) White Matter (l) VE (PD) (m) VE (T2) (n) Grey matter (o) White Matter Figure 1: Image Sequences and Probability Maps (a) (b) Figure 2: Bias Image and histogram 6

References 1. Clarke, et. al. MRI: Stability of Three Supervised Segmentation Techniques. Mag. Res. Imag.11,1,pp 95-106, 1993. 2. Cohen,et.al., Segmentation Techniques for the Classification of Brain Tissue Using MR Images. Psych. Res.,45,1, pp 33-51. 3. H.Rusinek, et. al. Alzheimer s Disease: measuring loss of cerebral grey matter with MR imaging. Radiology, 178(1), pp 109-14, 1991. 4. Vaidyanathan, et. al., Normal Brain Volume Measurements using Multispectral MRI Segmentation. Mag. Res. Imag., 15, 87-97, 1997. 5. Zijdenbos and Dawant, Brain Segmentation and White Matter Lesion Detection in MR Images. Crit. Rev. Biomed. Eng., 22, 5-6,pp 401-65, 1994. 7