POLYCAPILLARY OPTICS BASED NEUTRON FOCUSING FOR SMALL SAMPLE NEUTRON CRYSTALLOGRAPHY

Similar documents
LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Neutron Instruments I & II. Ken Andersen ESS Instruments Division

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

research papers Neutron transmission through pyrolytic graphite monochromators

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

SYNCHROTRON X-RAY MICROBEAM CHARACTERIZATION OF SMECTIC A LIQUID CRYSTALS UNDER ELECTRIC FIELD

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Small Angle Neutron Scattering in Different Fields of Research. Henrich Frielinghaus

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

Data Acquisition. What choices need to be made?

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES

RIETVELD REFINEMENT WITH XRD AND ND: ANALYSIS OF METASTABLE QANDILITE-LIKE STRUCTURES

1 Introduction Goal of calculating the analytical model of the instrument Basic method Parameters out of optimization...

High-Resolution Neutron Diffraction Monochromators for Neutron Diffractometry

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

X-RAY MICRODIFFRACTION STUDY OF THE HALF-V SHAPED SWITCHING LIQUID CRYSTAL

at Oak Ridge National Laboratory.

Laser-Modulator System

object objective lens eyepiece lens

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

SAXS and SANS facilities and experimental practice. Clement Blanchet

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

Diffractometer. Geometry Optics Detectors

Excitations. 15 th Oxford School of Neutron Scattering. Elizabeth Blackburn University of Birmingham. Blackburn et al., Pramana 71, 673 (2008)

Neutron Physics. The De Broglie relation for matter is: h mv (1) λ =

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

Setting The motor that rotates the sample about an axis normal to the diffraction plane is called (or ).

Structure Report for J. Reibenspies

M2 TP. Low-Energy Electron Diffraction (LEED)

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Focusing Optics. From x-ray telescopes to Compact Neutron Sources. Focus. Boris Khaykovich David Moncton Nuclear Reactor Laboratory, MIT

Neutron Imaging at Spallation Neutron Sources

Set-up for ultrafast time-resolved x-ray diffraction using a femtosecond laser-plasma kev x-ray-source

Fadei Komarov Alexander Kamyshan

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

Scattering Lecture. February 24, 2014

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Newsletter 1/2014. Super-polished copper a new substrate material. Fabrication of neutron collimators launched

Chapter 1 X-ray Absorption Fine Structure (EXAFS)

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Beyond the Geometric toward the Wave Optical Approach in the Design of Curved Crystal and Multilayer Optics for EDXAS

APPLICATION OF SPALLATION NEUTRON SOURCES

Time of flight SANS data Reduction (nothing really new here, but perhaps presented in unfamiliar ways)

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

PoS(ECPD2015)042. Hardened x-ray crystal spectrometer. Speaker. C. Reverdin 1, L. Lecherbourg, V. Dervieux, D. Gontier, B. Loupias. S.

X-Ray Emission and Absorption

arxiv: v3 [nucl-ex] 18 May 2018

On the use of Kumakhov Polycapillaries to improve laboratory

electronic image products. Images are produced from the best available original document.

School on Pulsed Neutrons: Characterization of Materials October Neurton Sources & Scattering Techniques (1-2)

Transmission Electron Microscopy

Neutron Diffraction: a general overview

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

Status report of CPHS and neutron activities at Tsinghua University

Light ion recoil detector

AN EXAFS STUDY OF PHOTOGRAPHIC DEVELOPMENT IN THERMOGRAPHIC FILMS

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

Laser Dissociation of Protonated PAHs

Optical/IR Observational Astronomy Telescopes I: Optical Principles. David Buckley, SAAO. 24 Feb 2012 NASSP OT1: Telescopes I-1

High-Resolution. Transmission. Electron Microscopy

05 - Scintillation detectors

Neutron facilities and generation. Rob McQueeney, Ames Laboratory and Iowa State University

Changing and challenging times for service crystallography. Electronic Supplementary Information

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

Low dimensional neutron moderators for enhanced source brightness

X-RAY OPTICAL CONSIDERATIONS ON PARABOLIC GRADED MULTILAYERS ON THE DIFFRACTED BEAM SIDE IN X-RAY DIFFRACTION

Astronomy 203 practice final examination

Imaging Self-Organized Domains at the Micron Scale in Antiferromagnetic Elemental Cr Using Magnetic X-ray Microscopy

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Steven C. DeCaluwe a,b, Paul A. Kienzle b, Pavan Bhargava b,c, Andrew M. Baker b,d, Joseph A. Dura b

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

New algoritms for electron diffraction of 3D protein crystals. JP Abrahams, D Georgieva, L Jiang, I Sikhuralidze, NS Pannu

Experimental study of nonlinear laser-beam Thomson scattering

Secondary Ion Mass Spectrometry (SIMS)

sin" =1.22 # D "l =1.22 f# D I: In introduction to molecular electron microscopy - Imaging macromolecular assemblies

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

arxiv: v1 [physics.ins-det] 6 Jun 2018

Demonstration of a novel focusing small-angle neutron scattering

AMOR the time-of-flight neutron reflectometer at SINQ/PSI

AP5301/ Name the major parts of an optical microscope and state their functions.

Determination of the boron content in polyethylene samples using the reactor Orphée

XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY

THE SUPER-FRS PROJECT AT GSI

SSRL XAS Beam Lines Soft X-ray

PHY410 Optics Exam #3

Two-Stage Chirped-Beam SASE-FEL for High Power Femtosecond X-Ray Pulse Generation

arxiv: v1 [physics.ins-det] 9 Apr 2018

Transcription:

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 306 POLYCAPILLARY OPTICS BASED NEUTRON FOCUSING FOR SMALL SAMPLE NEUTRON CRYSTALLOGRAPHY W.M. Gibson a, H.H. Chen-Mayer b, D.F.R. Mildner b, H.J. Prask b, A.J. Schultz c, R. Youngman a, T. Gnäupel-Herold b, M.E. Miller c, and R. Vitt c a) X-Ray Optical Systems, Inc., Albany, NY, b) National Institute of Standards and Technology, Gaithersburg, MD, c) Argonne National Laboratory, Argonne, IL ABSTRACT This work presents preliminary measurements designed to explore a new approach to neutron diffraction that is somewhat analogous to the pseudo-laue technique, except that instead of using a broad energy (wavelength) bandwidth it uses a broad angular bandwidth. We have used a polycapillary focusing optic to focus neutrons from a monochromatic beam (using the BT-8 spectrometer on the NIST research reactor) and from a polychromatic beam at a pulsed spallation source (the Intense Pulsed Neutron Source, IPNS at Argonne National Laboratory) into a small, intense spot and have carried out preliminary diffraction measurements. Using the single crystal diffraction (SCD) facility on IPNS, diffraction of a 3 o convergent beam from an alpha quartz crystal showed six diffraction beams in the 1-5 Å wavelength bandwidth transmitted by the optic. The diffraction spots showed an intensity gain of 5.8±0.9 compared to a direct beam diffracting from the same sample volume as that illuminated by the convergent beam. 1. INTRODUCTION Rapid, accurate, high-resolution structural analysis of proteins is central to the success of rational drug design and other medical and scientific applications. Neutron diffraction has powerful and unique potential for determination of the structure and dynamics of proteins including direct determination of hydrogen positions, solvent association, etc. (Timmins, 1995). However, the low intensity, broad energy (wavelength) bandwidth and large angular spread of neutron beams and the limited availability of neutron sources have kept this potential from being realized. A particularly serious limitation arises from the small size of the crystals available for medically important proteins. Other cases that involve the use of small crystals or small sampling areas include strain or phase distributions in metals (for example, at welds), and measurement of the structure and phase changes of materials at high pressure or low temperature. Also, mapping of composition in lateral directions by prompt neutron activation analysis requires small size, high intensity neutron beams. Another important feature of neutron diffraction arises from the lower energy of neutrons compared to that of X-rays of the same wavelength. For example a 0.034 ev neutron and an 8.03 kev X-ray both have a wavelength of 1.54 Å. This leads to reduced radiation damage during neutron irradiation and therefore longer crystal lifetime during diffraction measurements which, among other things, reduces the need to cool the crystal during the measurement. Also the penetration (or scattering mean-free-path) of neutrons is much greater than for x rays and the lower attenuation reduces anisotropic absorption effects for platelike or rod-like crystals that often leads to errors in x-ray analysis which are sometimes difficult to eliminate. In addition, because neutrons scatter from the nuclei, the scattering power for neutrons does not fall off dramatically with scattering angle as does X-rays. This means that higher resolution data should be easier to obtain with neutron diffraction. The "pseudo-laue" method has been used to permit a wide wavelength bandwidth to be used with either a reactor-based source (Wilkinson, 1991) or a pulsed spallation source (Schoenborn, 1992a). In addition to providing a larger usable neutron intensity, this technique samples a larger volume of reciprocal space on each exposure, therefore, requiring fewer exposures to cover the angular space necessary for a structure determination.

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 307 The work reported here represents preliminary measurements designed to explore a new approach that is somewhat analogous to the pseudo-laue technique except that instead of using a broad energy (wavelength) bandwidth it uses a broad angular bandwidth. We have used a polycapillary focusing optic to focus neutrons from a monochromatic beam (using the BT-8 spectrometer on the NIST research reactor) and from a polychromatic beam at a pulsed spallation source (the Intense Pulsed Neutron Source, IPNS at Argonne National Laboratory) onto a small, intense spot and have carried out preliminary diffraction measurements on IPNS. Polycapillary optic focusing of cold neutrons has been shown to be effective, giving intensity gains of nearly 100 x and spot sizes ~500 µm (Chen, 1992; Xiao, 1994). Convergent beam x-ray crystallography has already been demonstrated for protein crystals with lattice constants up to 70 Å with a resolution better than 2 Å (Owens, 1996; Huang, 2001). It is the combination of these developments that form the basis for enhanced neutron-based small-sample crystallography, the initial stages for which are described in this paper. The use of a convergent beam results in elongated diffraction spots that require modified software for analysis (Ho, 1998). Contrary to simple expectation, this elongation does not result in an untenable overlap problem, even for protein crystals. Aside from low index orientations, the diffraction streaks are displaced from each other, and provided that the streak widths are small compared to their separation they can be independently integrated and indexed (Ho, 1998). The widths of the diffraction streaks are determined by the mosaic spread of the crystal and the sample (or beam) size. The pseudo- Laue technique also produces elongated diffraction spots (Schoenborn, 1992b), although these differ in nature from those produced by a convergent beam. Enhanced neutron intensity at the focal spot can be used to increase the integrated intensity in the diffraction spots and also increase the reciprocal space sampled in each exposure. Both of these effects increase the efficiency for neutron diffraction structure determinations. Of particular importance is the fact that the smaller sample size (<500 µm) can greatly increase the number and types of proteins or other molecules that can be studied. The reduced sample size also reduces the width of the diffracted spots, allowing the sample-to-detector distance to be reduced, so that all of the diffracted spots needed for each crystal position can be measured simultaneously. These effects, taken together, have the potential to dramatically increase the opportunity and accessibility for neutron diffraction analysis especially for biological macromolecules. It should be noted that the efficiency for polycapillary focusing of neutrons depends on the neutron wavelength. At present, effective focusing can be done only for neutrons with λ>~1å, and is therefore less useful for measurement of small molecules than for medium to large molecules. Such cases, however, are where the need is greatest because of the difficulty of growing large, highly perfect crystals of macromolecules and because of their lower scattering strength. In summary, the potential benefits of polycapillary-based convergent beam neutron crystallography include smaller crystal size, larger sampled reciprocal space, higher neutron current density on small samples, and smaller diffracted spot widths, allowing the detector to be closer to the sample and therefore measure a larger solid angle subtended at the sample. This paper reviews a preliminary study of these potential benefits. 2. EXPERIMENTAL RESULTS A. Monolithic polycapillary optic The principles and schematic structure underlying the operation of a monolithic polycapillary focusing optic are shown in Fig. 1. The optic fabricated for this project has the following characteristics: length, 75 mm; cross section, hexagonal; input, 7.4 mm flat-to-flat; output, 5.6 mm; channel size at input, 8.8 µm; output focal distance, 98 mm; transmission efficiency for CuKα x-rays (8.1 kev), 24.7 % (x rays out/x rays in)(measured in reverse, collimating, geometry). A photograph of the enclosed optic is shown in Fig. 2.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 308 The optic was mounted in a high precision, remotely controlled alignment system with five degrees of freedom: three orthogonal translations, with 25 mm range and 10 µm precision; and two orthogonal angular motions, θ x, and θ y, with 0.25 mrad (0.0014 o ) precision. B. Focusing of monochromatic neutrons. Measurements were performed on the BT-8 beam line at the 20 MW NIST Research Reactor at five different neutron wavelengths; 1.08 Å, 1.40 Å, and 1.67 Å, using diffraction from a (220) copper monochromator crystal; and 2.40 Å and 3.10 Å from a (200) copper monochromator crystal. The gain of the optic at each neutron wavelength was obtained from the ratio of the number of neutrons within the full-width-at-half-maximum (FWHM) for a Gaussian distribution fitted to the measured peak to the number of neutrons within the same size spot without the optic. A summary of all of the Figure 1. Schematic of polycapillary monolithic focusing optic. Figure 2. Photograph of neutron focusing optic mounted in the alignment jig. measurements of the optic gain and the focal spot size for each neutron wavelength is shown on Fig. 3. The gain measurement for 1.67 Å neutrons is low because of imprecise alignment for that measurement and the FWHM for 3.1 Å neutrons is affected (reduced) by the presence of higher order 1.55 Å neutrons. The transmission efficiency and therefore the gain of the optic is strongly dependent on the angular distribution of the neutron beam at the optic input. fwhm (mm) gain Figure 3. Summary of measurements with the neutron focusing optic 1123-01 on the NIST BT-8 Spectrometer with a Cu diffraction crystal. C. Focusing of polychromatic neutrons. Measurements were made with the same optic on the single crystal diffractometer (SCD) beam line at (IPNS) at Argonne National Laboratory. The source operates at 30 Hz with fw hm (m m ) 450 MeV protons in 0.3 µs wide pulses impinging 0 0 0 1 2 3 4 on Wavelength (Å) 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 BT-8 monolithic lens gain vs. wavelength λ (Å) 1.1 1.4 1.67 2.4 3.1 a depleted uranium target with a time-averaged current of 15 µa. The SCD beam line views a 100 mm wide liquid methane moderator at a distance of 9.5 meters. This means that the neutron angular divergence at the input to the SCD instrument is less than ±5 mrad, which is a better match to the acceptance angle for the neutron focusing optic than the beam from 3 2.5 2 1.5 1 0.5 gain

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 309 the NIST BT-8 spectrometer, especially for the longer wavelength portion of the 0.5Å 5.0 Å wavelength bandwidth. The transmission through the optic was determined by computer simulation calculations using the measured neutron spectrum and angular distributions. The transmission efficiency of the optic as a function of the incident neutron wavelength was also calculated. For both the calculations and the measurements a 6 mm aperture defined the beam size at the entrance to the optic. Figure 4 shows the results of this calculation, which assumes that the same input angular distribution applies for all wavelengths. These results can be approximated over the wavelength range 1.5 Å < λ < 6 Å by the expression [8.3 λ - 9.8)/90. Applying the results of Fig. 4 and the measured input neutron spectrum, it is possible to obtain the neutron wavelength spectrum for neutrons exiting the optic (in the focal spot). This is shown in Fig. 5. In addition to the focal spot, there was a background of high-energy (short wavelength) neutrons. The measured focused neutron-to-background ratio (within the FWHM) of the focal spot was 20.0 ± 1.5. From scans of the focal spot, the measured spot width FWHM = 413 ± 13 µm, and after a small correction for the high-energy neutron background the Gain = 3.96 ± 0.32. Measurements were also made with a 127 mm Be absorber in the beam just before the optic. This removes neutrons with wavelength λ < 4 Å. For this condition the measured FWHM = 836 ± 39 µm and the Gain = 5.43 ± 0.23. Transmission Efficiency 0.6 0.5 0.4 0.3 0.2 0.1 0.0 Monolithic neutron focusing optic Length : 75 mm Input Diameter: 8.5 mm (6 mm aperture) Output Diameter: 6.4 mm Output Focal distance: 100 mm 1 2 3 4 5 6 o Wavelength (A) Intensity 1.0 0.8 0.6 0.4 0.2 0.0 Transmitted Spectrum for Argonne lens 0 1 2 3 4 5 Wavelength (A) o Figure 4. Simulated transmission vs neutron wavelength. Figure 5. Spectrum of focused neutrons from optic on IPNS SCD D. Diffraction measurements. Preliminary single-crystal time-of-flight neutron diffraction data were measured using the IPNS single crystal diffractometer (SCD) (Schultz, 1984; Schultz, 1993) equipped with a position-sensitive 6 Li-glass scintillation area (300 mm x 300 mm) detector. Because of the pulsed nature of the source, neutron wavelengths are determined by time-of-flight based on the de Broglie equation λ = (h/m). (t/l), where h is Planck's constant, m is the neutron mass, and t is the time-of-flight for a total flight path l, so that the entire thermal spectrum of neutrons can be used. With a position-sensitive area detector and a range of neutron wavelengths, a solid volume of reciprocal space is sampled with a stationary orientation of the sample and the detector. A schematic representation of the IPNS SCD is shown in Figure 6. A single crystal of alpha-quartz was aligned in the neutron beam at the normal crystal position. The crystal had approximate dimensions of 3 x 2 x 2 mm 3 ; thus, it was about 30 times larger than the focused beam. Time-of-flight Laue diffraction data were collected in a wavelength range of 0.7Å 4.2 Å. With the optic, six diffraction peaks were observed after 16.7 hours, all with wavelengths between 1.5 Å and 3.1 Å. A selected time slice through the diffraction peak at λ = 2.4 Å is contoured in Figure 7a. For comparison, Figure 7b shows the same peak obtained after 1.5 hours without the optic. The ratio of sample volumes illuminated by the incident neutron beam with and without the optic of 1:30 between 7a and 7b accounts for the different measurement times.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. Peak profiles for the same two peaks are shown in Figure 8. These closely approximate a typical 2θ scan from a conventional diffractometer. In this case, each count for a particular X channel was summed over the Y and TOF channels. The higher background in Figure 8a relative to 8b is primarily due to the longer counting time of 16.7 hours versus 1.5 hours. Each peak was fit to a Gaussian shape from which the derived FWHM values are 2.2 channels without the optic (8b) and 4.5 channels with the optic (8a).. Figure 6. Schematic representation of the IPNS Single Crystal Diffractometer (SCD). The moderator-to-sample distance is 9340 mm and the sample-to-detector distance is 320 mm. Figure 7. Contours of quartz Bragg peaks. Each channel (pixel) spans about 9.4 millirad. Contour increments are 30 counts starting at 15. a) Peak from quartz crystal with optic. b) Peak without optic. (a) (a) (b) (b) Figure 8. Plots of the detector horizontal scan for peaks a) with and b) without the focusing optic. Each point is integrated over the vertical channels and the time channels. for this peak. The solid line is a Gaussian fit to each peak. Integration of the peak intensities for 8a and 8b, normalized to the same sampling volume and sampling time shows a gain of 5.8 ± 0.9 for the focusing optic compared to a measurement on a small (500 µm 310

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 311 diameter) sample without the optic. This is larger than the gain of 4.0 * 0.3 measured with the entire incident beam. The difference may be due to the single wavelength region at 2.4 A which could give a higher transmission efficiency and a larger sampling volume than used for the gain calculation (included in the estimated uncertainty of this value). 3. CONCLUSIONS The diffraction measurement carried out in this study was designed only to explore the feasibility of using. a convergent beam for diffraction. It is clear that for a sample size much greater than 0,5 mm and small lattice constant crystal such as the quartz crystal used, the optic offers no particular benefit. The wavelength range sampled (1.5A-4 A as shown in Fig. 5) included only 6 diffraction peaks (compared to 39 when the entire spectrum is used). However these results show that although the convergent beam broadens the diffraction peaks as expected, this is not serious. The intensity gain observed in the focused beam incident on the sample is also present in the diffracted beams. This demonstrates the feasibility of applying a convergent beam to small sample diffraction measurements. The total convergence angle of the beam used in these studies was - 3. The neutron current density and therefore the optic gain can be further increased by decreasing the output focal distance of the optic. Recently, a monolithic neutron focusing optic was made with an output focal distance of 20 mm. This optic has been studied using the cold neutron beam at the NIST reactor and gave a focal spot size of 100 pm and gain of 46 (with an effective convergence angle of -6 ). We plan to investigate the use of this optic and perhaps even stronger focusing optics for neutron diffraction. 4. ACKNOWLEDGEMTS The identification of commercial materials and instruments in this paper is for an adequate description of the experimental facilities and procedures; it does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials and equipment are necessarily the best available for the purpose. Work at Argonne National Laboratory was supported by the US Department of Energy, Office of Basic Energy Sciences, Division of Materials Sciences, under contract No. W-3 l-109-eng-38. This work was also supported in part by the US Department of Energy through Argonne National Laboratory under contract OF-01385, and has benefited from the results of work supported by NASA under contract #NCC8-125. We also thank the NIST Center for Neutron Research for the use of the BT-8 instrument. 4, REFERENCES Chen, 1992; H.H. Chen, R.G. Downing, D.F.R. Mildner, W.M. Gibson, M.A. Kumakhov, I.Yu. Ponomarev, and M.V. Gubarev, Guiding and Focusing Neutron Beams using Capillary Optics, Nature, 357, 391-3 (1992) Ho, 1998; J.X. Ho, E.H. Snell, R.C. Sisk, J.R. Ruble, D.C. Carter, S.M. Owens, and W.M. Gibson, Stationary Crystal Diffraction with a Monochromatic Convergent X-ray Source and Application for Macromolecular Crystal Data Collection, Acta. Cyst., D54,200-214 (1998) Huang, 2001; H. Huang, CA. MacDonald, W.M. Gibson, I. Ponomarev, D.C. Carter, J.X. Ho, J.R. Ruble, J. Chik, and A. Parsegian, Focusing Polycapillary Optics for Diffraction Proc. 50th Annual Denver X-Ray Conference (these proceedings) (2001) Owens, 1996; S.M. Owens, J.B. Ullrich, I.Yu. Ponomarev, D.C. Carter, R.C. Sisk, J.X. Ho, and W.M. Gibson, Protein Crystal Structure Measurements Using Polycapillary X-Ray Optics, SPIE Proc., vol. 2859,200-209 (1996) Schoenborn, 1992a; B. P. Schoenborn, Area Detectors for Neutron Protein Crystallography, Proc. SPIE, vol. 1737,235-243 (1992)

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 312 Schoenborn, 1992b; B. P. Schoenbom, Multilayer Monochromators and Super-mirrors for Neutron Protein Crystallography Using a Quasi Laue Technique, Proc. SPIE, vol. 1738, 192-l 98 (1992) Schultz, 1984; A.J. Schultz, K. Srinivasan, R.G. Teller, J.M. Williams, and C.M. Lukehart, Single Crystal Time-of-Flight Neutron Diffraction Structure of Hydrogen cis-diacetyltetracarbonylrhenate, [cis- (OC)4Re(CH3C0)2]H: A Metallaacetylacetone Molecule, J, Am. Chem. Sot., 106, 999-1003 (1984) Schultz, 1993; A.J. Schultz, Trans. Am. Crystallogr. ASSOC., 29, 29-41 (1993) Timmins, 1995; P.A. Timmins, Structural Molecular Biology: Recent Results from Neutron Diffraction, Physica B, 213,26-30 (199.5) Wilkinson, 1991; C. Wilkinson and M.S. Lehmann, Quasi-Laue Neutron Diffractometer, Nucl. Instr. Meth., A31,411-415 (1991) Xiao, 1994; Q.-F. Xiao, H.H. Chen, V.A. Sharov, D.F.R. Mildner, R.G. Downing, N. Gao, and D.M. Gibson, Neutron Focusing Optic for Submillimeter Materials Analysis, Rev. Sci. Instrum., 65, 3399-3402 (1994)