U74C563 UNISONIC TECNOOGIES CO., TD OCTA TRANSPARENT D-TYPE ATCES WIT 3-STATE OUTPUTS DESCRIPTION The U74C563 is a octal traparent D-TYPE latches with 3-state outputs. When the latch-enable (E) is high, the Q outputs follow the complements of the D inputs. When E is low, the Q outputs are latched at the inverses of the levels set up at the D inputs. When the output-enable ( OE ) input is high, the Q outputs are in a high-impedance state, and the outputs neither load nor drive the bus lines. The high-impedance state and increased drive provide the capability to drive bus lines without interface or pull-up components. While the outputs are in the high-impedance state, old data can be retained or new data can be entered, i.e. OE does not affect the internal operatio of the latches. When OE is low, the Q outputs are in a normal logic state (high or low levels). The U74C563 is designed for 1.65 to 3.6 operation. Inputs can be driven from either 3.3 or 5 devices, so the U74C563 can be used in a mixed 3.3/5 system environment. To eure the high-impedance state during power up or power down, OE should be tied to CC through a pull-up resistor; the minimum value of the resistor is determined by the current-sinking capability of the driver. FEATURES * Wide supply voltage range from 1.65 to 3.6 * Max t PD of 6.8 from D to Q at 3.3 * Max t PD of 7.6 from E to Q at 3.3 * Up to 5.5 inputs accept voltages * ow power coumption, I CC = 10μA (Max.) at 3.6 * ±24mA output driver at 3 * I OFF supports partial-power-down mode operation ORDERING INFORMATION Ordering Number ead Free alogen Free Package Packing U74C563-P20-R U74C563G-P20-R TSSOP-20 Tape Reel U74C563-P20-T U74C563G-P20-T TSSOP-20 Tube 1 of 6 Copyright 2011 Unisonic Technologies Co., td
U74C563 PIN CONFIGURATION FUNCTION TABE (each latch) INPUTS OUTPUT OE E D Q X OGIC DIAGRAM (positive logic) X X Q 0 Z UNISONIC TECNOOGIES CO., TD 2 of 6
U74C563 ABSOUTE MAXIMUM RATING (unless otherwise specified) PARAMETER SYMBO RATINGS UNIT Supply oltage CC -0.5~6.5 Input oltage IN -0.5~6.5 oltage (any output in the high-impedance or power-off state) OUT -0.5~6.5 oltage (any output in the high or low state) OUT -0.5~ CC +0.5 Input Clamp Current I IK -50 ma Clamp Current I OK -50 ma Current I OUT ±50 ma CC or GND Current I CC ±100 ma Storage Temperature T STG -65 ~ +150 C Note: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. RECOMMENDED OPERATING COMDITIONS PARAMETER SYMBO CONDITIONS MIN MAX UNIT Supply oltage CC Operating 1.65 3.6 Data retention only 1.5 CC = 1.65 to 1.95 0.65* CC igh-evel Input oltage I CC = 2.3 to 2.7 1.7 CC = 2.7 to 3.6 2 ow-evel Input oltage I CC = 2.3 to 2.7 0.7 CC = 1.65 to 1.95 0.35* CC CC = 2.7 to 3.6 0.8 Input oltage IN 0 5.5 oltage OUT igh or low state 0 CC 3 state 0 5.5 CC =1.65-4 igh-evel Current I O CC =2.3-8 CC =2.7-12 ma CC =3-24 CC =1.65 4 ow-evel Current I O CC =2.3 8 CC =2.7 12 ma CC =3 24 Input Traition Rise or Fall Rate Δt/Δv 0 10 / Operating Temperature T A -40 85 C UNISONIC TECNOOGIES CO., TD 3 of 6
U74C563 EECTRICA CARACTERISTICS (T A =25 C, unless otherwise specified) PARAMETER SYMBO TEST CONDITIONS MIN TYP MAX UNIT I O = -100μA, CC = 1.65 to 3.6 CC -0.2 I O = -4mA, CC = 1.65 1.2 igh-evel oltage O I O = -8mA, CC = 2.3 1.7 I O = -12mA, CC = 2.7 2.2 I O = -12mA, CC = 3 2.4 I O = -24mA, CC = 3 2.2 I O = 100μA, CC = 1.65 to 3.6 0.2 I O = 4mA, CC = 1.65 0.45 ow-evel oltage O I O = 8mA, CC = 2.3 0.7 I O = 12mA, CC = 2.7 0.4 I O = 24mA, CC = 3 0.55 Input eakage Current (D, E, or OE inputs) I I(EAK) IN = 0 to 5.5, CC = 3.6 ±5 μa OFF-state Current I OFF IN or O = 5.5, CC = 0 ±10 μa igh-impedance state Current I OZ O = 0 to 5.5, CC = 3.6 ±10 μa Quiescent Supply Current I CC I OUT = 0, IN = CC or GND, 10 CC =3.6 IN =3.6 to 5.5,in disabled state 10 μa Additional quiescent Supply One input at CC -0.6, CC =2.7 to 3.6, Δ I CC Current other inputs at CC or GND 500 μa Input Capacitance C IN IN = CC or GND, CC =3.3 (Note 1) 4 pf Capacitance C OUT OUT = CC or GND, CC =3.3 (Note 1) 5.5 pf Note: 1. All typical values are at CC = 3.3, T A = 25 C. TIMING REQUIREMENTS(T A =25 C) PARAMETER SYMBO TEST CONDITIONS MIN MAX UNIT Pulse duration, E high t W CC = 2.7 3.3 CC = 3.3±0.3 3.3 Setup time, data before E CC = 2.7 2 t SU CC = 3.3±0.3 2 old time, data after E CC = 2.7 1.5 t CC = 3.3±0.3 1.5 SWITCING CARACTERISTICS (T A =25 C) PARAMETER SYMBO TEST CONDITIONS MIN MAX UNIT t P /t P CC =2.7, C =50pF, R =500Ω 7.8 from input D to output Q (t PD ) CC =3.3±0.3, C =50pF, R =500Ω 1.5 6.8 t P /t P CC =2.7, C =50pF, R =500Ω 8.2 from input E to output Q (t PD ) CC =3.3±0.3, C =50pF, R =500Ω 2 7.6 from input OE to output Q from input OE to output Q t PZ /t PZ (t EN ) t PZ /t PZ (t DIS ) OPERATING CARACTERISTICS (T A =25 C) CC =2.7, C =50pF, R =500Ω 8.7 CC =3.3±0.3, C =50pF, R =500Ω 1.5 7.7 CC =2.7, C =50pF, R =500Ω 7.6 CC =3.3±0.3, C =50pF, R =500Ω 1.5 7 PARAMETER SYMBO TEST CONDITIONS TYP UNIT Power Dissipation Capacitance C PD OE = 0, f=10mz, outputs enabled 46 OE = 1, f=10mz, outputs disabled 3 pf UNISONIC TECNOOGIES CO., TD 4 of 6
U74C563 TEST CIRCUIT AND WAEFORMS TEST t P /t P t PZ /t PZ t PZ /t PZ S1 Open OAD GND CC Inputs IN t R, t F OAD C R Δ 2.7 CC 2.5 1.5 6 50pF 500Ω 3.3±0.3 CC 2.5 1.5 6 50pF 500Ω 0.3 UNISONIC TECNOOGIES CO., TD 5 of 6
U74C563 TEST CIRCUIT AND WAEFORMS(Cont.) IN Input t P t P 0 O O t P t P O O oltage Waveforms Propagation Delay Times IN Input t PZ t PZ 0 OAD /2 S1 at OAD O + Δ O t PZ t PZ S1 at Open O - Δ O 0 oltage Waveforms Enable and Disable Times Notes: 1. C includes probe and jig capacitance. 2. All input pulses are supplied by generators having the following characteristics: P RR 10Mz, Z O = 50Ω. UTC assumes no respoibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specificatio of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written coent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECNOOGIES CO., TD 6 of 6