FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Similar documents
Chemistry Instrumental Analysis Lecture 15. Chem 4631

Advanced Pharmaceutical Analysis

Spectroscopy. Fourier Transform Infrared (FT-IR) Spectroscopy

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

Vibrational Spectroscopies. C-874 University of Delaware

Mid-IR Sampling Techniques for Biological Molecules

Glossary. Analyte - the molecule of interest when performing a quantitative analysis.

Introduction to Fourier Transform Infrared Spectroscopy

Infrared spectroscopy. Siriphorn Laomanacharoen Bureau of Drug and Narcotic Department of Medical Sciences 2 March 2012

Mid-IR Methods. Matti Hotokka

Introduction to Fourier Transform Infrared Spectroscopy

Application of IR Raman Spectroscopy

Fourier Transform IR Spectroscopy

Infrared Spectroscopy: Identification of Unknown Substances

Infra Red Spectroscopy

Reference Standards Page 156 For calibrating your spectrometer. PIKECalc Page 159 For FTIR sampling computations

INFRARED SPECTROSCOPY

Spectroscopy in Inorganic Chemistry. Vibration and Rotation Spectroscopy

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

Fourier Transform Infrared. Spectrometry

Educational experiment package Volume 1. Molecular spectroscopy

Molecular Spectroscopy In The Study of Wood & Biomass

Infrared Spectroscopy

Skoog Chapter 6 Introduction to Spectrometric Methods

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Chem Homework Set Answers

m m lighter 'atom' dominates 2 INFRARED SPECTROSCOPY All modes of vibrations are not IR active.

FT-IR Spectroscopy. An introduction in measurement techniques and interpretation

Characterisation of vibrational modes of adsorbed species

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 4: Basic principles and Instrumentation for IR spectroscopy

Instrumental Chemical Analysis

Qualitative analysis of aramide polymers by FT-IR spectroscopy

All the manufacturers use a heated ceramic source.

Electromagnetic spectra

Overview and comparison of portable spectroscopy techniques: FTIR, NIR and Raman

1901 Application of Spectrophotometry

IR Spectrography - Absorption. Raman Spectrography - Scattering. n 0 n M - Raman n 0 - Rayleigh

Introduction to FT-IR Spectroscopy

Learning Guide for Chapter 3 - Infrared Spectroscopy

Infrared Spectroscopy

Lecture 0. NC State University

Fourier Transform Infrared Spectrometry

Determination of Chemical Composition and Molecular Microstructures: Infrared Spectroscopy

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Advanced Spectroscopy Laboratory

Ultraviolet-Visible and Infrared Spectrophotometry

Modern Techniques in Applied Molecular Spectroscopy

Reflection = EM strikes a boundary between two media differing in η and bounces back

Infrared Spectroscopy

Ch 313 FINAL EXAM OUTLINE Spring 2010

DOWNLOAD OR READ : INFRARED AND RAMAN SPECTROSCOPY CONCEPTS AND APPLICATIONS PDF EBOOK EPUB MOBI

Ultraviolet-Visible and Infrared Spectrophotometry

Near-Infrared Spectroscopy of Nitride Heterostructures EMILY FINAN ADVISOR: DR. OANA MALIS PURDUE UNIVERSITY REU PROGRAM AUGUST 2, 2012

Výběr z aplikací infračervené spektrometrie Ján Pásztor, Nicolet CZ s.r.o.

Infrared spectroscopy

Chapter 3. Infrared Reflectance Spectra of Tholins

1) What do all waves transport from one place to another?

Chapter 17: Fundamentals of Spectrophotometry

AS 101: Day Lab #2 Summer Spectroscopy

Handheld FTIR spectroscopy applications using the Agilent ExoScan 4100 FTIR with diffuse sample interface

Infrared Spectroscopy (IR)

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

Increasing energy. ( 10 4 cm -1 ) ( 10 2 cm -1 )

FTIR Spectrum Interpretation of Lubricants with Treatment of Variation Mileage

FHI Lecture Series Modern Methods in Heterogeneous Catalysis: Transient Infrared Spectroscopy

The DialPath Solution an Easier Way to Analyze Liquids By FTIR. Yanqia Wang, Ph.D. Application Engineer - FTIR Agilent Technologies May 7, 2015

Chapter 5 Light and Matter: Reading Messages from the Cosmos

Radiant energy is proportional to its frequency (cycles/s = Hz) as a wave (Amplitude is its height) Different types are classified by frequency or

School. Team Number. Optics

Wave - Particle Duality of Light

Chapter 5 Light and Matter: Reading Messages from the Cosmos. 5.1 Light in Everyday Life. How do we experience light?

Lecture 11. IR Theory. Next Class: Lecture Problem 4 due Thin-Layer Chromatography

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

Unit 11 Instrumentation. Mass, Infrared and NMR Spectroscopy

Gestão e Produção Sustentável. Durability Electromagnetic radiation. ENG K49 Materiais de origem vegetal aplicados na construção

Physics 30: Chapter 5 Exam Wave Nature of Light

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Topic 2.11 ANALYTICAL TECHNIQUES. High Resolution Mass Spectrometry Infra-red Spectroscopy

An FT-IR based instrument for measuring infrared diffuse reflectance

In-Situ FTIR Spectroscopy and Metrology of a Tungsten CVD Process

SPECTROSCOPY MEASURES THE INTERACTION BETWEEN LIGHT AND MATTER

PC Laboratory Raman Spectroscopy

Infrared Spectroscopy An Instrumental Method for Detecting Functional Groups

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

Electromagnetic Waves

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Chromatography & instrumentation in Organic Chemistry

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

OPSE FINAL EXAM Fall 2016 YOU MUST SHOW YOUR WORK. ANSWERS THAT ARE NOT JUSTIFIED WILL BE GIVEN ZERO CREDIT.

Chapter 17: Fundamentals of Spectrophotometry

and Environmental Science Centre

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Determination of Optical Constants of Polystyrene Films from IR Reflection-Absorption Spectra

Transcription:

FTIR Spectrometer Basic Theory of Infrared Spectrometer FTIR Spectrometer FTIR Accessories

What is Infrared? Infrared radiation lies between the visible and microwave portions of the electromagnetic spectrum. The Infrared region is divided into: near, mid and far-infrared. Near-infrared refers to the part of the infrared spectrum that is closest to visible light and far-infrared refers to the part that is closer to the microwave region. Mid-infrared is the region between these two.

Wavelength Range of Mid-IR Mid-IR:400~4000cm -1

The Infrared Radiation It is the radiation produced by the motion of atoms and molecules in an object. However, not all infrared light is absorbed by the molecule. Very specific frequencies are absorbed by specific groups or vibrations of the molecule.

Selection Rules for Infrared Activity The absorption is basically depending on these properties: The frequency of the infrared radiation must be identical to the (theoretical) frequency of the vibration of the molecule. We call this resonance. The dipole of the molecule, the distribution of the electrons in the molecule, has to change during the vibration. This means that even though every molecule vibrates all the time, not all vibrations absorb IR radiation.

Vibration of Molecules Each vibration, called a fundamental mode, has a specific energy (or frequency) which depends on the atoms involved in the motion (ie, mass of the weights), the type of motion, and the bond strengths (ie, the strength of the spring ). Symmetric Stretch Antisymmetric Stretch Bend The bonds between atoms in the molecule stretch and bend, absorbing infrared energy and creating the infrared spectrum.

Functional Groups and Fingerprint In Mid-Infrared region, the frequency of vibration is divided into two portions: functional groups and fingerprint. Functional groups always occur at similar positions in the spectrum: OH vibrations, CH 2 vibrations, Aromatic vibrations. These vibrations are spread over the entire spectrum, and most of them are pretty well known. The region between 1350 and 650 cm -1 is basically built up from very specific complicated vibrations of the entire molecule. Therefore, this region is different for every molecule, and like a fingerprint, no two molecules have the same fingerprint region. We can use this part of the spectrum for the final identification.

The Region of Functional Groups and Fingerprint Functional groups region(4000~1350cm -1 ): It is linked to functional groups in molecule. Fingerprint region(1350~650cm -1 ): It is related to whole molecular structure. This is the most well-known spectrum in IR spectroscopy: A polymer with CH 2 and benzene groups. Polystyrene Functional groups... Fingerprint region 3500 3000 2500 2000 Wavenumbers (cm -1 ) 1500 1000

Capabilities of Infrared Analysis Identification and quantitation of organic solid, liquid or gas samples. Analysis of powders, solids, gels, emulsions, pastes, pure liquids and solutions, polymers, pure and mixed gases. Infrared used for research, methods development, quality control and quality assurance applications. Samples range in size from single fibers only 20 microns in length to atmospheric pollution studies involving large areas.

Applications of Infrared Analysis Pharmaceutical Research Forensic Investigations Polymer Analysis Lubricant Formulation and Fuel Additives Foods Research Quality Assurance and Control Environmental and Water Quality Analysis Methods Biochemical and Biomedical Research Coatings and Surfactants Etc.

The Basic Components of FTIR Spectrometer

The Interferometer IR radiation passed into beamsplitter,50% of IR radiation be transmitted to the moving mirror,50% be reflected to the fix mirror. The two beams are reflected from these two mirrors, returning to the beam splitter where they recombine and interfere.

Fourier-Transform Infrared Spectrometers Fourier-transform infrared spectroscopy is based on the idea of the Interference of radiation between two beams to yield an interferogram. The interferogram is a signal produced as a function of the change of pathlength between the two beams. The two domains of distance and frequency are interconvertible by the mathematical method of Fourier-transformation. The radiation emerging from the source and passed through an interferometer to the sample before reaching a detector.

Fourier Transform Integrate the frequency, obtain the intensity of power. Single strength Optical path difference [x] spectrum And then obtain the intensity of power by the mathematical method of Fouriertransformation. 4000 400 Wavenumber[cm -1 ]

Advantages of FT Instruments Why would we rather use FT instruments than dispersive ones? There are three major advantages of FT instruments: Multiplex: since all wavelength are measured simultaneously,the measurement time is greatly reduced. Throughput: FT instruments don t use slits, therefore the amount of light entering into the instrument is much larger, and the measurement is less sensitive to noise. Precision: since we use an extremely accurate laser for the position determination of the mirror, the precision is very high, better than 0.01 cm -1. This is better for quantitative analysis and library searching.

infra 3000 Series FTIR Spectrometer Spectral range:7800cm -1 ~400cm -1 Resolution: better than 1cm -1 (3000A) better than 0.5cm -1 (3000B) Wavenumber accuracy:±0.01cm -1 Signal to noise ratio: better than 15000:1 Beam splitter: Ge be coated on KBr Detector: DTGS,MCT(optional) IR source: air-cooled, high efficiency

Accessories Hydraulic Press Gas Cell Diffuse/Specular Reflectance Liquid Cell Attenuated Total Reflection

Hydraulic Press Generally, you need to get a spectrum of powder samples through halogenide tablet pressing method. The most common preparation method is KBr tablet pressing method. (there are about 90% spectrums in pharmacopoeia selecting this method.) Hydraulic press is the essential tool for halogenide tablet pressing method. Samples are pressed to a transparent tablet after grind. It can get a very good infrared spectrum through transmitting method.

KBR Pellet for Solids To mix a solid sample with dry KBR powder. The little sample is needed and around 1 to 2mg sample with about 200mg KBR. Place mixed powder in the mould, and subjected to a pressure of 8~10MPa with one Minute. Sample and KBR must be dry to avoid the effect from water. The diameter of particles must be less than 0.2um, in order to avoid scattering results.

Gas Cell

Gas Cell Generally, it is composed by a glass cylinder with two pistons for gas in or out and two windows transmitting infrared. The length is 50mm or 100mm. The diameter is 30~40mm. The cylinder must be pumped into vacuum state first when sampling, then blow into the gas sample. The volatile liquid sample can also be put into the cell to measure its steam spectrum.

Liquid Cell

Fixed Liquid cells Fixed liquid cell, that is to say the thick of the cells is fixed. It is used for qualitative or quantitative analysis of volatile liquid and solution. The common material of windows is NaCl, KBr, CsI, KRS-5 and so on. The padding between the windows is Al, Pb or PTFE. The common thickness is 0.025, 0.05,0.1, 0.2, 0.5, 1.0mm.

Demountable liquid cell When analysing non-volatile liquid sample, you can choose Demounted cells. It is composed by a metal holder and two windows between which there is a suitable neoprene or PTFE padding. Put the liquid into the cells with syringe when measuring. Please open the cells to clear when finishing measurement or changing sample.

Diffuse Reflectance Specular Reflectance Diffuse Reflectance When the incident light get to sample surface, may be partly reflected regularly, partly scattered diffusely, and partly enter the substrate. The latter part may undergo absorption with particles, emerge at the sample surface and intermingle with reflected parts.

Attenuated Total Reflection(ATR) Horizontal attenuated total reflectance accessory is used in analysis of liquid, semi-liquid materials and a number of soft solids. In general, sampling is achieved by placing the sample onto the HATR crystal generally eliminating sample preparation.

Horizontal ATR A beam of radiation entering a crystal will undergo total internal refection when the angle of incidence at the interface between the sample and crystal is greater than the critical angle,where the latter is a function of the refractive indices of the two surfaces.the beam penetrates a fraction of a wavelength beyond the reflecting surface, when a material that selectively absorbs radiation is in close contact with the reflecting surface,the beam loses energy at the wavelength where the material absorbs.

Single- reflection ATR Single-reflection ATR further simplify sample preparation and also reduce the complexity of traditional FTIR measurements. This is achieved through the reduction of the sampling area, easy of cleaning and the introduction of more rigid, diamond-protected sampling interfaces.

Single reflection ATR Capable of withstanding higher pressures and harder samples. Capable of analyzing a wide variety of samples-including rigid solids and hard powders-which are difficult to achieve with a multi-reflection ATR. Also it works very well for the analysis of relatively strong absorbing substances, (e.g. polymers, rubber, paint chips, fibers, etc.)

Single-reflection ATR It s unique optical design provides exceptional sensitivity and IR throughput. The compact design of the accessary employs a transfer mirror to direct the infrared beam to one end of an IR transmitting ATR crystal(or specular reflectance mirrors). A second mirror directs the beam emitted from the other end of the crystal to the detector built into your FTIR spectrometer.

Experimental Method 1 Gas Gas Cell 2 Liquids Volatile Liqiud Fixed Liqiud Cell Involatile Liqiud Demounted Liquid Cell Attenuated Total Reflection(ATR) Coating Liquid on KBr Disc Powder d 0.2um Kbr Discs 3 Solids d 0.2um Diffuse Reflectance Pliable Solids Attenuated Total Reflection(ATR)

Thanks!