Numerical modeling of the primary source in a hemi-anechoic room

Similar documents
Influence of directivity and spectral shape on the measured sound power level

Sound field decomposition of sound sources used in sound power measurements

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Analysis of shock force measurements for the model based dynamic calibration

Measurement of airflow resistance by the alternating flow method

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

Simulation of Horn Driver Response by Direct Combination of Compression Driver Frequency Response and Horn FEA

Traceability of on-machine measurements under a wide range of working conditions

Prediction of Sound Propagation From Power Transmission Plant

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Sound power level determinations at laboratory and field environments: An experimental comparison

Nanoholes for leak metrology

Evaluation of standards for transmission loss tests

Sound radiation and transmission. Professor Phil Joseph. Departamento de Engenharia Mecânica

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

EFFECTS OF PERMEABILITY ON SOUND ABSORPTION AND SOUND INSULATION PERFORMANCE OF ACOUSTIC CEILING PANELS

Engineering Noise Control

SIMULATION OF ORGAN PIPES ACOUSTIC BEHAVIOR BY MEANS OF VARIOUS NUMERICAL TECHNIQUES

European Project Metrology for Radioactive Waste Management

FDTD analysis on the sound insulation performance of wall system with narrow gaps

A simplified method of VNA uncertainty estimation

Static pressure and temperature coefficients of working standard microphones

1. Introduction. 2. ISO 3745 and ISO standard comparison

Porous Materials for Sound Absorption and Transmission Control

OPAC102. The Acoustic Wave Equation

Consultancy Report Ref: 9383-R01

Laser scanning vibrometry measurements on a light weight building element

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Uncertainties associated with the use of a sound level meter

QUANTIFYING ACOUSTIC SOURCES THROUGH SOUND POWER MEASUREMENTS

WHITE PAPER. Challenges in Sound Measurements Field Testing JUNE 2017

Modeling and simulation of windows with noise mitigation and natural ventilation

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

MAC Aura XB Acoustic Test Report

UNCERTAINTY EVALUATION OF SINUSOIDAL FORCE MEASUREMENT

Drop towers and fitness flooring assemblies

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

Computational Acoustics by Means of Finite and Boundary Elements for Woofers, Tweeters, Horns and Small Transducers

Measurement of Acoustic Properties of light weight concrete SL-Deck

Acoustic design of lightweight cabin walls for cruise ships

Micro-perforated sound absorbers in stretched materials

Radiated sound power estimates of building elements by means of laser Doppler vibrometry

ON SOUND POWER MEASUREMENT OF THE ENGINE IN ANECHOIC ROOM WITH IMPERFECTIONS

Noise in enclosed spaces. Phil Joseph

Acoustic response in non-diffuse rooms

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient

Develop and characterize a flow metering standard down to 1 nl/min

17. Investigation of loudspeaker cabinet vibration using reciprocity

45º CONGRESO ESPAÑOL DE ACÚSTICA 8º CONGRESO IBÉRICO DE ACÚSTICA EUROPEAN SYMPOSIUM ON SMART CITIES AND ENVIRONMENTAL ACOUSTICS

Investigation of the acoustic black hole termination for sound waves propagating in cylindrical waveguides

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

A practical device to determine the reflection coefficient of acoustic materials in-situ based on a Microflown and microphone sensor

Testing Procedure: AS ISO

Guided convected acoustic wave coupled with a membrane wall used as noise reduction device

New techniques in computer aided noise abatement for workplaces next to machinery Wolfgang Probst

Characterisation of structure-borne sound sources

Experimental approach on natural frequency of window vibration induced by low frequency sounds

Influence of background noise on non-contact vibration measurements using particle velocity sensors

Numerical Model of the Insertion Loss Promoted by the Enclosure of a Sound Source

The information included in the following report presents the results of sound pressure and sound power testing.

Transmission Loss of a Dissipative Muffler with Perforated Central Pipe

TRANSMISSION LOSS OF EXTRUDED ALUMINIUM PANELS WITH ORTHOTROPIC CORES

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement

A PRECONDITIONER FOR THE HELMHOLTZ EQUATION WITH PERFECTLY MATCHED LAYER

A LOW-FREQUENCY METASURFACE ABSORBER BASED ON HELMHOLTZ RESONATORS

INTER-NOISE AUGUST 2007 ISTANBUL, TURKEY

CONSOLIDATED GRANULAR MEDIA FOR SOUND INSULATION: PERFORMANCE EVALUATION THROUGH DIFFERENT METHODS

Simulation of acoustic and vibroacoustic problems in LS-DYNA using boundary element method ABSTRACT:

r p = r o r cos( φ ) cos( α )

Characterization and Calibration of a Fourier Transform Spectroradiometer for Solar UV Irradiance Measurements

University of Kentucky

ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS

Proceedings of Meetings on Acoustics

ROOM RESONANCES USING WAVE BASED GEOMET- RICAL ACOUSTICS (WBGA)

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE

A SIMPLE DECOUPLED MODAL CALCULATION OF SOUND TRANSMISSION BETWEEN VOLUMES

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 NUMERICAL SIMULATION OF THE ACOUSTIC WAVES PROPAGATION IN A STANDING WAVE TUBE

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

Witold MIKULSKI. Central Institute for Labour Protection National Research Institute Czerniakowska 16, Warszawa, Poland;

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Development of a small-scale reverberation room

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements

Radiated Sound Power from a Curved Honeycomb Panel

Absorption boundary conditions for geometrical acoustics

In-situ measurements of the complex acoustic impedance of materials in vehicle interiors

Modified wave equation for modelling diffuse sound field

ISO INTERNATIONAL STANDARD

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

The in-flight calibration system for the airborne imager GLORIA

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Influence of loudspeaker directivity on the measurement uncertainty of the acoustic testing of facades.

Sound radiation and sound insulation

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Verification of Sound Absorption Characteristics Constituted Porous Structure

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

D. BARD, J. NEGREIRA DIVISION OF ENGINEERING ACOUSTICS, LUND UNIVERSITY

Transcription:

Numerical modeling of the primary source in a hemi-anechoic room R. Arina 1, K. Völkel 2 1 Politecnico di Torino, Torino, Italy 2 Physikalisch Technische Bundesanstalt, Braunschweig, Germany ABSTRACT An effective use of the primary source requires a deep knowledge and understanding of the governing phenomena that influence its sound power output. The paper reports on a numerical model for describing the acoustic behavior of the primary source in an hemi-anechoic room. The wave equation is discretized in the frequency space with a high-order Finite Element method. Fully reflecting boundary conditions are imposed along the room floor, while suitable partially-reflecting boundary conditions, using absorbing layers, are specified on the anechoic walls to mimic real conditions. In the free-field computation the lining is considered as perfectly absorbing, and in real case reflective properties are considered. The major primary source properties, such as sound power and directivity index are calculated for low frequencies. Challenge is here to separate the effects of the wall room reflections from the source properties. Keywords: Sound power, Free Field, Directivity INTRODUCTION The sound emission of a source is most objectively described by its sound power output. Consequently there are several standardized procedures for the determination of the sound power of a source. Until now all of these measurements suffer from the lack of primary standard for the realization of the unit Watt in airborne sound. Such a primary sound source was developed as part of the European Metrology Research Programme SIB 56. This source is based on a vibrating baffled piston [2]. Measurements with this device are carried out in PTB s hemi-anechoic room which provides an approximation of a free sound field. Two distinct measurement procedures are applied to obtain the sound power of the primary standard: the first method employs a laser-scanning vibrometer that scans the surface of the primary source and records data on vibration velocity and phase. For the second method sound pressure levels are measured on a hemispherical surface around the source and sound powers are calculated according to ISO 3745. The frequency range measured with the primary source extends from 20 Hz to 20 khz. It is known that the sound field assumption is of utmost importance in the determination of correct sound power levels when these are calculated from sound pressure measurements [3]. Thus, the main limiting factor in the comparability of the sound power levels obtained by the two described methods is the ability of PTB s hemi-anechoic room to provide a good approximation of a free field. This is especially relevant for low frequencies. For this reason a numerical study was conducted that contrasted the sound power measured for a monopole in either PTB s hemi-anechoic room or in a room of the same geometry but providing a perfect free field. Three single frequencies were chosen for a first test and are reported here. They are 50 Hz, 100 Hz and 150 Hz. HEMI-ANECHOIC ROOM AT PTB The hemi-anechoic room at PTB has a pentagonal sound reflecting base plate (Fig. 1). Free field conditions are achieved through the use of sound absorbing wedges of length 0.80 m. These are installed on all room walls as well as the ceiling. With wedges installed, the room height is 4.65 m and the longest side lengths 1 email: renzo.arina@polito.it 2 email: katharina.voelkel@ptb.de 6749 1

z y θ S ϕ Figure 1: Reference frame for directivity indexes. x are 6.5 m and 6.25 m, respectively. The volume of the room is 184.1 m 3 with wedges and 337.4 m 3 without wedges. To assess the quality of the free field achieved in this room, the absorption coefficients of two sets of wedges consisting of two wedges each were measured in a Kundt s tube. The absorption coefficients averaged over six measurements were then supplied as boundary condition for the numerical simulation of PTB s hemianechoic room (Fig. 2). Figure 2: Absorption coefficients of the wedges in PTB s hemi-anechoic room for different frequencies. NUMERICAL SIMULATIONS Propagation of acoustic waves in still air is governed by the linearized Euler equations which reduce into a scalar wave equation for the pressure (or density) fluctuations. For time-harmonic problems the wave equation reduces to the Helmholtz equation. The main purpose of the present work, to compare the acoustic behavior of a monopole in a perfect and a real hemi-anechoic chambers, is to model the acoustic propagation in the confined chamber with appropriate boundary conditions able to mimic as close as possible the real absorbing and reflecting characteristics of the vertical walls and the ceiling. In the case of perfectly non-reflecting walls, a widely used technique to prevent numerical reflections is the so-called Perfectly Matched Layer (PML) method [4]. It consists into the construction of a layer exterior to 6750 2

the domain of interest damping all the waves that enter from the interior domain. This layer is represented by a modified Helmholtz equation which is not necessarily physically realizable. The uniqueness of the PML method is that the dissipation properties are essentially independent of the angle of incidence and also of the frequency of the incoming wave. The method consists in introducing a fictitious complex stretching of the spatial variables (x, y, z), with the substitution / x s x (x) / x, where s x =1+ σ x(x) ik with k the wave number. The modified Helmholtz equation reads ( ) sy s z p + ( ) sx s z p + ( ) sx s y p + s x s y s z k 2 p =0. (1) x x y y z z s x s y Outside the PML regions, σ x = σ y = σ z =0and the modified equation (1) reduces to the Helmholtz equation. No reflections at the interface between the interior domain and the PML occur if σ x (x) > 0 and varies at least linearly inside the sponge layer, and the PML width is large enough to have a complete damping. To mimic partially reflecting walls, it is proposed to employ a partially absorbing PML boundary condition, by an appropriate choice of a constant value of σ x, σ y and σ z. The selection of the correct value of the σ functions is based on experimental data of the absorption coefficient measured in a Kundt s tube. The calibration procedure is obtained solving the acoustic problem in the impedance tube replacing the absorbing end wall with a PML boundary condition. Evaluating the sound pressure at two points, x 1 and x 2, inside the tube, in the case of harmonic plane waves the transfer function H 12 = p 2 / p 1 is related to the reflection coefficient R as, with Δ=x 2 x 1, The absorption coefficient is obtained as, s z R = H 12 e ikδ e ikδ H 12 e 2ikx1. α = (p i) rms (p r ) rms (p i ) rms =1 R 2. In Table (1) are reported the values of the function σ for different frequencies and the computed absorption coefficients α. The numerical values of the absorption coefficient are close to the measured values in the case of the PTB hemi-anechoic chamber reported in Figure (2). The numerical solution of the acoustic pressure field generated by a monopole placed near the floor of the PTB hemi-anechoic chamber is obtained solving the Helmholtz equation with a FEM discretization and imposing fully reflecting boundary conditions on the floor and PML conditions on the vertical walls and the ceiling. The FEM system is solved using the FreeFem++ software [5]. DATA ANALYSIS Data analysis focused on a hemisphere with radius 1.5 m centered on the floor with x- and y-coordinates corresponding to those of the monopole source. Frequencies considered were 50 Hz, 100 Hz and 150 Hz. For each frequency, directivity indexes were calculated both for the real hemi-anechoic room as well as the ideal free field as ( ) p 2 DI =10log i 10 db. p 2 ref The reference sound pressure used was that recorded along the z-axis. The directivity indexes corresponded to arcs along the hemisphere with ϕ =0, ϕ =45 or ϕ =90 (Fig. 1). Secondly, sound power levels (L W ) for both the ideal as well as the real room were calculated for each frequency by averaging the sound pressure levels on a mean square basis (L p ) and taking into account the hemispherical measurement surface (S) referenced to the value S 0 =1m 2, as follows ( ) S L W = L p +10log 10 db. S 0 6751 3

Table 1: PML coefficient and numerical absorption coefficient in function of the frequency f Hz σ α 20 0.150 0.180247 30 0.350 0.371084 40 0.600 0.548428 50 1.100 0.767195 60 1.700 0.89485 70 2.400 0.958402 80 3.100 0.983531 90 3.400 0.988932 100 3.400 0.988942 125 4.500 0.997413 150 5.000 0.998685 175 7.000 0.999908 200 8.000 0.999972 225 8.000 0.999973 250 8.000 0.999975 275 8.000 0.999971 300 5.000 0.998699 RESULTS Results show that at 50 Hz and 100 Hz there is a significant difference in sound power levels obtained for the real and ideal room. This difference becomes negligible at 150 Hz (Tab. 2). This shows that the hemi-anechoic room at PTB does not provide a good free sound field up to a frequency of 100 Hz. At a frequency of 150 Hz though, the sound field in the measurement room at PTB is a good approximation of a free field. Table 2: Comparison of sound power levels for ideal and real room Frequency (Hz) L W,ideal (db) L W,real (db) ΔL W,real ideal (db) 50 80.0 80.9 0.83 100 92.3 92.9 0.61 150 96.1 96.2 0.08 The sound power results are confirmed by plots of the directivity of sound emission for different values of the azimuthal angle, ϕ. At50 Hz (Fig. 3) and 100 Hz (Fig. 4) an influence of the cut off corner in the geometry of PTB s measurement room is visible for both the ideal as well as the real sound fields. This is due to the sharp slope change at that corner which introduces spurious reflections in the numerical model. However, comparing the directivity plots of real and ideal test rooms, it is evident that there are reflections from the walls of PTB s hemi-anechoic room which obliterate the uniform sound emission of the tested monopole to some extent. These effects vanish at 150 Hz (Fig. 3). The directivities for the monopole in the real and ideal test room show no significant difference for that frequency. There is also no effect of the non-perfect rectangular geometry of the test rooms anymore. This confirms the results obtained in the comparison of sound power levels: PTB s hemi-anechoic room provides a good approximation of a free field at 150 Hz. 6752 4

Figure 3: Directivity indexes at f = 50 Hz for ϕ =0, ϕ =45 and ϕ =90 from top to bottom. 6753 5

Figure 4: Directivity indexes at f = 100 Hz for ϕ =0, ϕ =45 and ϕ =90 from top to bottom. 6754 6

Figure 5: Directivity indexes at f = 150 Hz for ϕ =0, ϕ =45 and ϕ =90 from top to bottom. 6755 7

CONCLUSION This paper presented first results on a comparison of sound power levels and directivities for a monopole source in a perfect free field vs. a real measurement room. Investigating three frequencies (50 Hz, 100 Hz and 150 Hz) it was shown that the real measurement room at PTB does not provide a good free field at or below 100 Hz. This result needs to be considered when comparing sound power levels obtained for the primary sound source using a laser-scanning vibrometer vs. pressure measurements. A more detailed study is needed to define the lower frequency limit for PTB s hemi-anechoic room as well as to investigate and quantify whether effects are more or less pronounced using FFT or one-third octave band analysis. ACKNOWLEDGMENT The work presented in this paper is part of the European Metrology Research Programme (EMRP) joint research project SIB 56 "SoundPwr". The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. REFERENCES [1] ISO 3745:2012 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Precision methods for anechoic rooms and hemi-anechoic room [2] Wittstock, V., Schmelzer, M., Bethke, C.: Establishing traceability for the quantity sound power. Proceedings of Internoise, 2013. [3] Wittstock, V.: A new approach in sound power metrology. OIML Bulletin, 55(2):9-13, 2014. [4] Abarbanel S. and Gottlieb D., A mathematical analysis of the PML method, J. Comput. Physics, 134:357-363, 1997. [5] Hecht F., New developments in FreeFem++, J. Numer. Meth., 20(3-4):251-265, 2012. 6756 8