Continuous Flow Analysis Methods David Davey University of South Australia. 21 February

Similar documents
Automating Wet Chemical Analysis

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Method for Nitrite determination on Low-Range Samples

By Mohsin Al-Saleh Clinical Biochemistry Department (SQUH)

Automation of Wet Chemical Analysis Methods

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

DBP Control: Chloramine Chemistry. Chris Griffin Hach Company

Automated Photometry. Presented by Scott Tucker. Instruments

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

DI 3500 Discrete Aoalvzer

If you like us, please share us on social media. The latest UCD Hyperlibrary newsletter is now complete, check it out.

RECENT ADVANCES AND FUTURE TRENDS IN FLOW INJECTION AND THEIR APPLICATION TO CHEMICAL OCEANOGRAPHY

Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet

Determination of the Scavenging Capacity Against Reactive Nitrogen Species by Automatic Flow Injection-Based Methodologies

Analytical Chemistry-I

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

in Lab-on-Valve System

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Speed and flexibility

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Reagents for Chemical Test Kits

A New On-line Cyanide Analyzer for Measurement of Cyanide in Hydrometallurgical Processing of Precious Metal Ores

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION)

SECTION D.2 AMMONIA NITROGEN

Cyanide Analysis with the CNSolution 3100

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

A LAZAR LABORATORY HANDBOOK MEASUREMENT OF NITRIC OXIDE IN BIOLOGICAL SAMPLES

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

HPLC Praktikum Skript

FIA Coupled to Capillary Electrophoresis - A Tool for Process Monitoring?

CHLORAMINATION AND CHLORAMINE ANALYSIS SW AWWA 2014

Flow Injection Analysis for the Determination of Ammonia in Exhaust Gas of Thermal Power Plant

O Sodium Bicarbonate, NaHCO 3 Ammonium Molybdate Tetrahydrate, (NH 4. O 4 Sodium Chloride, NaCl Ascorbic Acid, C 6 H 8 O 6

Cyanide, colorimetric, pyridine-pyrazolone

DETERMINATION OF NITRATE AND NITRITE BY ZONE FLUIDICS

Chemical Oxidation Oxidizing agents

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Analysis of Free Ammonia in Chloramination Applications Using Lab Method and the APA6000

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Sampling for Gases and Vapors

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Paper 4.3. Introduction

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Factors affecting zone penetration

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Standard Operating Procedure for the Analysis of Nitrate/Nitrite and Nitrite in Fresh Waters CCAL 31B.1

Orderly Arranged Fluorescence Dyes as a Highly Efficient Chemiluminescence Resonance Energy Transfer Probe for Peroxynitrite

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Automation of Routine Microplate Pipetting and Dispensing

Total Kjeldahl Nitrogen by Gas Diffusion and Flow Injection Analysis (FIA)

Understanding Chlorine Measurement. Rebecca Luedee Environmental Sales

Single Method On-line Analyzers. ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter

Water Hardness and Softening (Bring a water sample from home) Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.2.

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Principles of micro Sequential Injection Analysis in the Lab-on-Valve format and its Introduction into a Teaching Laboratory

Figure Small ByT-FAS raw data plots of a quinine tracer injected into the sample carrier stream.

METHOD STATEMENT. Determinand: Ammonia, Chloride, Nitrate, Nitrite, Orthophosphate, Sulphate & TON. Matrix: Leachates, effluents and wastewaters

1225 Lab # 11 Fluoride Speciation and Analysis by Flow Injection using Ion-Selective Electrode: Measurement of Total Fluoride in Water

Deep Desulfurization of Diesel using a Single-Phase Micro-reactor

Exercise 6: Determination of Hardness of Water

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Fig. Electrochemical Cell/ Potentiometric Titration

Investigation of Petasis and Ugi Reactions in Series in an Automated Microreactor System

Medicine Concentration in the AutoStart Burette following an Automatic Flow Restart Event

Flow Solution FS 3700 Automated Chemistry Analyzer

Nutrient Analysis, Nitrate, Nitrite, Silicate, Phosphate and Ammonium

Total Kjeldahl Nitrogen (TKN), USEPA by Flow Injection Analysis (FIA)

Spectrophotometric Determination of Anionic Surfactants in River Water with Cationic Azo Dye by Solvent Extraction- Flow Injection Analysis

SYNTHESIS OF AN AZO DYE revisited (1 or 2 credits)

Nitrogen in All Its Forms. Assoc. Prof. Kozet YAPSAKLI

Shorten your Time-to-Result

Disinfection. What is disinfection? Why to disinfect?

N-NITROSODIETHANOLAMINE (NDELA) IN COSMETICS

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Reprint. Project Summary. Side by Side Evaluation of ChemScan UV-4100 and Hach (Dr. Lange) Optiquant at Littleton-Englewood Colorado

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

Disinfection. Disinfection is used to treat both domestic water and wastewater.

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

Development of an Automatic Sampling Module to Monitor Concentration of Liquid-Borne Nanoparticles

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Automation of the radiochemical procedures for the sequential separation of radionuclides

Lab #12: Determination of a Chemical Equilibrium Constant

Generation and absorption of CO2 gas

2011_ST20_Taylor.pdf. SSPT Document not peer-reviewed by CORESTA

Examples of Strong Acids: Strong Acid Formula Common Source Hydrochloric Acid HCl Stomach Acid

CHEMISTRY DEPARTMENT

Alcohol dehydrogenase Assay Kit

J. Flow Injection Anal., Vol. 13, No. 2 (1996)

Particle Charge Titration Zeta Potential Size Distribution

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater

PRELIMINARY ACTIVITY FOR

salicylic acid and acetylsalicylic acid in pharmaceuticals

Transcription:

Continuous Flow Analysis Methods David Davey University of South Australia 21 February 2012 1

Flow Analysis Methods 1950s-60s Segmented Flow Methods Clinical Analysis Skeggs 1970s Flow Injection Analysis Chemical Analysis Ruzicka and Hansen, Pungor Tecator Lachat GlobalFIA FIAlab 1980s Sequential Injection Marshall, Ruzicka Lab on a valve 1990s MicroTotal Analysis Systems Lab on a chip 21 February 2012 2

21 February 2012 3

Continuous Flow Analysis Methods David Davey University of South Australia 21 February 2012 4

Reagent Carrier Flow Cell Sample Pump Sample Sensors WASTE 21 February 2012 5 GND

Lab on a Chip 21 February 2012 6

Segmented Flow Analysis Automated systems in many older laboratories 3 AIR Pump 5 Detector 1 2 4 Mixing coil 1 2 Sample Reagent Basic Layout of SFA instrument 21 February 2012 7

SFA Bolus= Volume of Sample and Reagents which remains largely intact in the flow system Manifold= The collection of tubing and connectors which: transports sample and reagent, creates the bolus, promotes mixing, and delivers the reaction product to a detector 21 February 2012 8

Segmented Flow Analysis AIR 21 February 2012 9

Some SFA Features Samples are pumped into the manifold Air separates sample boluses where reaction occurs Air (and some sample) must be removed before the detector Steady state signals are sought, and dispersion is thus small Manifold tube diameters are usually 2-3 mm. Flow is controlled and turbulent Sample throughput is 2-5 per minute. 21 February 2012 10

Flow Injection Analysis Basic Layout of FIA instrument 1 Pump Sample valve 3 Detector 4 2 Mixing coil 1 4 Carrier or Reagent 1 Reagent 2 21 February 2012 11

Some FIA Features Samples are injected/intercalated into the manifold Air bubbles are not wanted! Steady state signals are not required Manifold tubes are less than 1 mm in diameter Flow is controlled and mostly laminar Sample throughput can be very fast, and is often < 1 sample per minute 21 February 2012 12

Flow Analysis Methods Segmented Flow SFA Tubing 2 mm ID Air segmented Sample 1-2 ml Flow Injection Analysis FIA Tubing < 1 mm ID Sample 10-100µL Microconduits Channels 0.5 mm 21 February 2012 13

Flow Analysis Methods Segmented Flow SFA Tubing 2 mm ID Air segmented Sample 1-2 ml Flow Injection Analysis FIA Sequential Injection Analysis SIA Tubing < 1 mm ID Sample 10-100µL Microconduits Channels 0.5 mm 21 February 2012 14

Flow Analysis Methods Segmented Flow SFA Flow Injection Analysis FIA Sequential Injection SIA Holding & Mixing Coil Channels < 1 mm ID Multdirectional Use of Syringe Pumps Samples10µL-100 µl 21 February 2012 15

Sequential Injection Analysis,SIA SIA uses the same chemistry as FIA and the reaction manifold is similar. A holding and mixing coil is a key component of the design. Samples and Reagents are loaded using:- a multi-directional valve minipumps or multistep syringes under PC control 21 February 2012 16

SIA setup Peristaltic Pump or Multi-step Piston Wash Reagent Detector Holding Coil Reaction Coil Light source Standard Sample 21 February 2012 17

1. Flow Injection Analysis Automated systems in most laboratories small samples are introduced into a continuous liquid stream for controlled reaction and delivery to a detector FIA requires excellent time and volume control an important analytical tool in determining large numbers of samples rapidly and precisely 21 February 2012 18

FIA Physical Needs Multichannel Pump Sample Injection Valve Flow Through Detector 21 February 2012 19

Flow Injection Analysis Basic Layout of FIA instrument 1 Pump Sample valve 3 Detector 4 2 Mixing coil 1 4 Carrier or Reagent 1 Reagent 2 21 February 2012 20

Flow Injection Analysis continued 1 Carrier The carrier may provide some medium control, but not form a product with the analyte. The carrier could control interfering species through ph control By complexation of an interfering compound 21 February 2012 21

Flow Injection Analysis continued 1 4 Reagent(s) FIA relies on carefully optimised conditions and selective chemistry and/or a selective detector to pick out a key compound in a sample. Colorimetric or Fluorimetric Analysis are dominant methods employed. UV-visible detector measures the absorbance of the product of reaction with the analyte, or Fluorescing product gives out light to a detector Chemiluminescent product gives out light to a detector 21 February 2012 22

Methods characterised by Dispersion FIA & SIA Dispersion is the process which is utilised in FIA (& SIA) to create unique analysis methods Dispersion Factor, Df defines the amoiunt of mixing employed 21 February 2012 23

Dispersion is measured relative to a Steady State result D f =1 A Steady State in FIA is a signal which is the maximum achievable for that manifold. The observed response could be decided by sample volume kinetics mixing characteristics 21 February 2012 24

Low dispersion Flow Injection Analysis sample delivery to electrodes, optodes, atomic spectrometers etc with minimal treatment Medium dispersion sample reaction in multipath manifolds with processes in-stream such as preconcentration, sample-reagent mixing, heating and time delays to achieve a particular sensitivity before a product reaches the detector High dispersion methods using enhanced concentration gradients eg in-stream titrations 21 February 2012 25

Dispersion Coefficient D f = C o /C = H o /H Flow Injection Analysis D f range Low dispersion 1 3 Medium dispersion >3 6 (Ruzicka -10) High dispersion >6-12 21 February 2012 26

Low dispersion Flow Injection Analysis Samples are delivered to a detector with minimal change Applications include:- Electrochemical Methods Atomic absorption Some adjustment may be made to the carrier stream TISAB, buffer Low concentration of the analyte 21 February 2012 27

Examples ph, pf, pca ph 4.6 Pump Sample valve 5.5 1 2 Mixing coil 6.5 6.8 6.7 1 Water 8.0 2 TISAB 9.0 21 February 2012 28

Medium dispersion Urea in serum ml/min Flow Injection Analysis Sample 30 µl Urease 0.5 Hypochlorite 1.2 620 nm Phenol 1.6 Standards 4-25 mm Samples 21 February 2012 29

Other Examples Phosphate in water or soil via vanadomolybdate polyphosphate complexation Sulfur dioxide in beverages forms a dyestuff with para-rosaniline at 550 nm. Ammonia or Chloramine in water via indophenol reaction Nitrite in food via azo-dye formation 21 February 2012 30

High Dispersion Peak Width Measurements FIA provides extraordinary control of mixing processes. Thus in-stream reactions have found peak width as the parameter useful In-stream titration Concentration zones EDTA reagent Ca electrode 21 February 2012 31

Information in a peak The response curve is a repository of information peak height or area = k [analyte] peak width = k log [analyte] 21 February 2012 32

Flow Injection Analysis High dispersion - In-stream titrations EDTA reagent Ca electrode Ca electrode EDTA reagent Analyte Ca ++ 21 February 2012 33

Flow Injection Analysis High dispersion - In-stream titrations t equivalence = k log[ca ++ ] t equivalence 21 February 2012 34

Some Questions to try 21 February 2012 35

Examine the literature to find details for: Phosphate in water or soil via vanadomolybdate polyphosphate complexation under acid conditions Ammonia or Chloramine in water via indophenol reaction Nitrite in food via azo-dye formation with napthylamine 21 February 2012 36

Ques1. Design 2 flow manifolds for N speciation Nitrogen speciation is a key measure in determining water quality. Measure ammonia using the NH 3 electrode Nitrate is first reduced on line to form nitrite which then reacts with napthylamine reaction to form an azo dye before a colorimetric end-point 21 February 2012 37

Design a manifold for SO2 in Wine Ques 2. Sulfur dioxide is a key preservative in beverages. It also has regulated levels under export rules. SO 2 is determined after p-rosaniline reaction under acid conditions, and the response read colorimetrically at 550 nm Total sulfur dioxide requires bound material, e.g. the bisulfite addition complex with aldehyde, be broken up first. 21 February 2012 38

Examine the literature to find details for: Phosphate in water or soil via vanadomolybdate polyphosphate complexation under acid conditions Ammonia or Chloramine in water via indophenol reaction Nitrite in food via azo-dye formation with napthylamine 21 February 2012 39

Selective determination of orthophosphate and total inorganic phosphates in detergents by flow injection photometric method Liu Jing-fu and Jiang Gui-bin, Talanta Vol 52, June 2000, 211-216 S C 0.7 1.2 1.2 HC CC DB 30µL RC D R 1.2 ml/min Pump 620 nm 21 February 2012 40

Questions on orthophosphate and total inorganic phosphate Manifold Assume HC is 100 cm of 1 mm tube. What is its volume (π R 2 L assume π =3)? How long will fresh sample take to travel through the coil? If RC has the same volume as HC, what is the approximate time taken by a new sample to reach the detector D? What do HC, CC and RC represent? Let s allow C and R to flush the detector cell (volume 0.2 ml) twice between introducing sample for reaction. For one sample, how many repeat analyses per minute might be possible? 21 February 2012 41

Questions & Answers on orthophosphate and total inorganic phosphate Manifold Assume HC is 100 cm of 1 mm Internal Diameter tube. What is its volume (π R 2 L assume π =3)? How long will fresh sample take to travel through the coil? Volume = π x(0.05^2)x100 ml = approx 0.8 ml 60 sec x 0.8/1.2 = 40 s If RC has the same volume as HC, what is the approximate time taken by a new sample to reach the detector D? HC 40 s ; RC 20 s (flow rate 2.4) gives Total 60 s 21 February 2012 42

Questions on orthophosphate and total inorganic phosphate Manifold cont d What do HC, CC and RC and DB represent? HC heated coil; CC cooling coil; RC analysis reaction coil; DB debubbler. Detergents are poly phosphates, and reaction is needed to break them down to PO 3-4. Frothing and thus bubblers need to be removed at DB. Let s allow C and R to flush the detector cell (volume 0.2 ml) twice between introducing sample for reaction. For one sample, how many repeat analyses per minute might be possible? The question is best seen as having A sample loaded to the injection valve. C and R flush the detector twice, volume 2 x 0.2 ml. Time 60 x 0.4/2.4 s=10 s Note that the injection valve has easily been rinsed and filled in this time. 60 x 0.03/1.2=1.5 s. So Repeat analyses (peak responses) would be possible 6 times per minute, 360 per hour. In 21 February reality 2012 rates such as 120-180 per hour are achieved. 43

Ammonia in Water NH3 + HOCl NH2 Cl + PhenylOH NH2 Cl + H2O NH2 Phenyl OH 0.3 S A B 1.0 1.0 100µL RC1 RC2 RC3 D C 1.0 Pump 660 nm ml/min 21 February 2012 44

Ammonia Manifold Questions Assume 1 mm tubes throughout. RC1 is 10 cm long. RC2 and 3 are 50 cm long. If these are the major volume elements, how long would a sample take to reach the detector? What would you suggest A, B and C are? Let s allow reagents to flush the whole manifold between introducing fresh sample for reaction. For one sample type, how many repeat analyses per hour might be possible? This is called the through put. Sample carryover implies reaction of one sample bolus with another. Suggest a maximum repeat sample injection for this system. 21 February 2012 45

Ammonia Manifold Questions Assume 1 mm tubes throughout. RC1 is 10 cm long. RC2 and 3 are 50 cm long. If these are the major volume elements, how long would a sample take to reach the detector? From previous question, volumes are 0.08 + 0.4+ 0.4 = 0.88 ml Each manifold component has its own flow rate so times are 4.8, 12 and 8 s total time = 25 s What would you suggest A, B and C are? A good answer would be: A ph control; B HOCl; C phenol Let s allow reagents to flush the whole manifold between introducing fresh sample for reaction. For one sample type, how many repeat analyses per hour might be possible? This is called the through put. Since 25 seconds are needed per sample, throughput= 60 x 60/25 =144 h -1 21 February 2012 46

Ammonia Manifold Questions Sample carryover implies reaction of one sample bolus with another. Suggest a maximum repeat sample injection for this system. I interpret this to mean how many 100 µl samples could squeeze into the manifold. It is roughly 1 in RC1; 4 in both RC2 and RC3. 4 in RC3 at 3 ml/min would imply a sample every 8/4 s or 1800 h -1! However if the volume D were 0.2 ml, 2 samples would end up in the detector cell at once! A mixed signal (carryover would result). The detector volume (and response time) is the ultimate limit on the analysis speed. 21 February 2012 47