Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Similar documents
Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Method Development with ZirChrom's Ion Exchange Phases

Oligonucleotide Separation on ZirChrom -SAX

Multi-mode Separations Using Zirconiabased Stationary Phases

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

New Applications of Zirconia Based Stationary Phases

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Determination of trace anions in concentrated hydrofluoric acid

Shodex TM ODP2 HP series columns

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

ProPac WCX-10 Columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Solid Phase Extraction Method Development Tips and Tricks

Characteristics and Advantages of Zirconia-Based Stationary Phases for Use in Multi-Dimensional HPLC

Reversed Phase Solvents

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

for Acclaim Trinity TM P1

Acclaim Mixed-Mode WAX-1 Columns

Isomer Separation on ZirChrom -CARB

Hints for Strong Ion Exchange Resins

Cellufine Butyl Cellufine Phenyl

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Cation Exchange HPLC Columns

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Packings for HPLC. Packings for HPLC

penta-hilic UHPLC COLUMNS

Comparison of different aqueous mobile phase HPLC techniques

Dionex IonPac AS28-Fast-4µm column

Mechanisms of retention in HPLC

High Performance Liquid Chromatography

High Performance Liquid Chromatography

ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Chapter 23 Introduction to Analytical Separations

Sepax SRT -C, Zenix -C SEC Phases

LC and LC/MS Column Selection Flow Chart

Retention and Selectivity Variables

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Advantages of polymerbased. an alternative for ODS

HPLC at High Temperature and High ph with a New, Highly Stable Silica Column

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Anion Exchange HPLC Columns

Cellufine Butyl Cellufine Phenyl

BETASIL Columns TG Å high purity silica

Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

Acclaim Mixed-Mode WCX-1

Reversed-Phase Method Development Guide

penta-hilic UHPLC COLUMNS

A C18 Silica Column With Exceptional Temperature and ph Stability

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

for Acclaim Mixed-Mode WCX-1

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

anion-exchange column

Alltech Alltima HP Introduction

Too Polar for Reversed Phase What Do You Do?

groups I and II cations, amines, divalent transition metals

Dilution(*) Chromatography

Cation Exchange HPLC Columns

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

1. Ion exchange chromatography

TCI Dual ~Mixed-Mode Mode column~

for Acclaim Mixed-Mode HILIC-1 Column

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Choosing Columns and Conditions for the Best Peak Shape

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

The Development of ZrO 2 Based HPLC: From Colloid to Column

Primesep TM. Solving Problems of Pharmaceutical HPLC Analysis. Creating New Dimensions in the World of Chromatography.

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Chapter content. Reference

columns IonPac AS17-C Anion Exchange Column

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance

Liquid Chromatography

Xiqin Yang, Jun Dai, Peter W. Carr* Chemistry Department University of Minnesota

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

State-of-the-art C18 HPLC Columns

C18 Column. Care & Use Sheet

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Looking into the HPLC Column while Running CIP

Transcription:

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka, MN 55303 2 Supelco, 595 North Harrison Road, Bellefonte, PA 16823 1-866-STABLE-1 www.zirchrom.com 1 1

Ion-Exchange LC (HPLC) Most ion-exchange LC has been done with polymer-based support particles. -Polymers often exhibit poor efficiency and are subject to dimensional change when exposed to high temperature, high pressure, high flow rate and organic solvents. Silica has not been highly successful as a base for ion-exchange. -Substrate has weak cation exchange properties which are not easy to reproduce and control; silanols overload easily and reduce column performance. -Coated and bonded phases can exhibit limited stability in aqueous solution over range of ph and temperature conditions needed for ion-exchange. Zirconia may be an ideal particle for ion-exchange. -Zirconia is rigid and very stable over a wide range of operating conditions. -Both cation and anion exchange versions are readily prepared. -Rugged industrial and biochemical ion separations may be developed or transferred by following standard rules for IEC or IC method development. Challenge- can ion-exchange LC-MS become a routine tool? 2 2

Review: Zirconia Chemistry Lewis Base: P 4 3-, F -, RC - R H C - H 2 H H H H 2 H2 Zr Zr Zr Zr Zr Zr Zr Strong Lewis Acid Site Dominates Chemistry Ligand exchange interaction : Zr-L + A - «Zr-A - + L When ligand is charged, surface becomes charged! * Base is electron donor; acid is electron acceptor; more general than Brönsted. 3 3

Four Zirconia-based ptions for IEC Bare zirconia - Phosphate, fluoride and other anionic additives that are replaceable. + Zr 2 primarily a strong cation exchanger (SCX) Zr 2 Zirconia with PEI coating Cross-linked to resist removal even under extreme conditions Weak anion exchanger (WAX) - Zr 2 Zirconia with EDTPA chelator modification Multidentate attachment Very stable, but can be replaced or restored + Zr 2 Zirconia with quaternized PEI coating Cross-linked to resist removal even under extreme conditions Strong cation exchanger (SCX) Strong anion exchanger (SAX) 4 4

Chelating Ligand Modification H 2 3 P CH 2 CH 2 CH 2 CH 2 P 3 H 2 N N H 2 3 P CH 2 CH 2 P 3 H 2 Ethylenediamine-N,N -tetra(methylenephosphonic) acid = EDTPA EDTPA treatment (reflux particles in EDTPA solution) Strong Lewis base chelate attaches to the surface Probably multidentate attachment- very strongly held Blocks undesirable Lewis acid/base interactions Imparts cation exchange (SCX) properties to zirconia Minimal RP behavior 5 5

0505 DTPA P 4 / Zr / Zr 2 Time (min) 2 Proteins on Zr-P 4 and ZirChrom-PEZ (EDTPA) 4 3 2 5 2 3 5 4 mm EDTPA 1. Myoglobin 2. Ribonuclease A 3. Chymotrypsin 4. Lysozyme 5. Cytochrome c Mobile phase, 50 to 500 mm K 2 HP 4 in 20 min., ph 7.0; Flow Rate, 1 ml/min; Detection, 280 nm. 6 6

Proteins on ZirChrom-PEZ Reduced form xidized form 0 5 10 15 20 Time (min) Gradient elution of cytochrome c from horse heart. Mobile phase, 4 mm EDTPA, 20 mm MES [2-(Nmorpholino)ethanesulfonic acid], ph 5.5 with a linear gradient of 0 to 1 M NaCl in 30 min; Detection, 410 nm. 7 7

Small-Scale Purification of MAB IgG 2a Contaminated with BSA mau 140 120 100 80 VWD1 A, Wavelength=280 nm (NIH22399\IGGBSA01.D) 2.682 Area: 5329.82 BSA Note: BSA is not retained under sample loading conditions. 60 40 20 12.678 Area: 2602.62 MAB 0-20 0.05 M NaCl 0.5 M NaCl 1.0 M NaCl 0 5 10 15 20 25 30 35min LC Conditions: ZirChrom-PEZ, 5 x 4.6mm (part#zr08-0546); 100 ul injection of BSA (6.0 mg/ml) contaminated MAB (1.0 mg/ml) eluted by salt step gradient; Mobile phase, 20 mm MES, 4 mm EDTPA, 0.05 M-to-1.0 M NaCl ph=5.5; Flow rate, 2.0 ml/min; Temperature: 30 o C; Detection, 280 nm. 8 8

Zirconia-PEI (Zr-PEI) for Anion Exchange Coat and crosslink polyethyleneimine (PEI) for weak anion exchange (WAX). Quaternize with methyl iodide for strong anion exchange (SAX). Lewis acid sites can compete for anions unless blocked by a stronger Lewis base. 9 9

Small Anions on ZirChrom -WAX mau 7 50 40 30 20 2 4 3 5 6 Addition of organic solvent may improve peak shape of organic anions by eliminating any RP effect. 10 0 1 8 9 0 2 4 6 8 10 12 14 min LC Conditions: Column, ZirChrom -WAX, 150 x 4.6 mm i.d. (part# ZR05-1546); Mobile Phase, 45mM ammonium phosphate dibasic at ph 8.2; Flow Rate, 1.0 ml/min; Detection, 240 nm; Column Temperature = 40 o C. Solutes: 1 = bromate, 2 = nitrite, 3 = benzoic acid, 4 = nitrate, 5 = p-chlorobenzoic acid, 6 = p-bromobenzoic acid, 7 = iodide, 8 = p-fluorobenzoic acid, 9 = p-iodobenzoic acid. 10 10

Trace Iodide Separation on ZirChrom -SAX Nitrate Peak Analytes: mau 3000 mau 50 100 ppm I - 2M nitrate sample matrix and Iodide 2500 40 2000 30 20 1ppm I - 10 1500 0 1000 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 min 500 0 0 1 2 3 4 5 6 LC Conditions: Column, ZirChrom -SAX, 50 x 4.6 mm, (part# ZR06-0546); Mobile Phase: 25mM ammonium phosphate, 275mM NaCl at ph 8.0; Flow Rate, 1.0 ml/min; Temperature, 30 C; Detection, 226 nm; Injection volume: 5 ul. 11 11

Green Analysis of Diet Soft Drinks Containing Caffeine and Aspartame mau 1400 1200 1000 800 600 400 200 0 Diet Sprite TM Diet Dr. Pepper TM Diet Mountain Dew TM Diet Pepsi TM Diet Coke TM 0 1 2 3 4 5 6 LC Conditions: Column, ZirChrom -SAX, 100 x 3.0 mm (part# ZR06-1030); Mobile Phase, 10mM Ammonium phosphate, 5mM Ammonium carbonate, ph 6.6; Flow rate, 1.0 ml/min; Temperature, 50 o C; Injection Vol., 5.0 ml; Pressure Drop, 205 bar; Detection, 210 nm. 12 12

mau 1 LC/MS Compatible Separation of Non- Steroidal Anti-Inflammatory Drugs (NSAIDs) on ZirChrom -SAX 8 6 4 2 2 3 4 5 1-Acetaminophen 2-Ibuprofen 3-Naproxen 4-Impurity 5-Ketoprofen 0 0 1. 2 3 min LC Conditions: Column, ZirChrom -SAX, 50 x 4.6 mm i.d. (part number: ZR06-0546); Mobile Phase, 80/20 ACN/15 mm ammonium formate, ph=4.0 (adjusted with formic acid); Flow Rate, 1.0 ml/min; Temperature, 35 o C; Injection Vol., 1.0 ml; Detection, 254 nm. 13 13

Water-Soluble Vitamin Analysis on ZirChrom -SAX 1 2 3 4 5 1 - Thiamine (Vit. B 1 ) 2 - Pyridoxine (Vit. B 6 ) 3 - Nicotinamide (form of Vit. B 3 ) 4 - Riboflavin (Vit. B 2 ) 5 - Nicotinic acid (form of Vit. B 3 ), 6 - Ascorbic acid (Vit. C) 6 Vitamin C is largely retained on ZirChrom-SAX 0 1 2 3 4 5 6 min. LC Conditions: Column: ZirChrom -SAX, 150 x 4.6 mm i.d. (part number: ZR06-1546); Mobile Phase, 50 mm Ammonium dihydrogenphosphate, ph 4.5; Flow rate, 1.0 ml/min; Temperature, 30 o C; Injection Vol., 5.0 ml; Detection, 254 nm. 14 14

Conclusions Zirconia is a very attractive LC substrate because of its unparalleled mechanical and chemical stability (especially in aqueous solution). It has great potential to become a primary substrate for both preparative and analytical ionexchange LC with UV, conductivity, electrochemical and other common detectors that can tolerate phosphate, fluoride, chloride, sulfate and other nonvolatile additives. Retention rules for ions are easily understood. Ionic strength gradients are tolerated by the packing (chlorides, sulfates, nitrates, etc.). Zirconia and the IEC mechanism are both tolerant of organic solvent to counter excessive hydrophobic solute retention or to elute hydrophobic interferences at the solvent front. Zirconia is potentially very useful for ion-exchange LC-MS of both positive ions (SCX mode) and negative ions (WAX and SAX modes) using volatile mobile phases or online clean-up. Ammonium acetate, ammonium formate, ammonium carbonate and ammonium hydroxide additives should be useful; effect of additives and ionic strength gradients on MS signal requires further investigation. IEC mode tolerates high organic to reduce RP effects and maximize MS-ESI signal. 15 15

For More Information, Visit Us at Booth 220 1-866-STABLE-1 www.zirchrom.com For more information and web access to the free Buffer Wizard: www.zirchrom.com 16 16