DEVICE FOR MEASUREMENT OF THERMAL EMISSIVITY AT CRYOGENIC TEMPERATURES

Similar documents
CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

ATMOS 5140 Lecture 7 Chapter 6

Thermal Field in a NMR Cryostat. Annunziata D Orazio Agostini Chiara Simone Fiacco

TIR100-2 Measurement of Thermal Emissivity

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

Development Of An Experimental Setup For Emissivity Measurement At Cryogenic Temperatures

Thermal Coatings for In-vacuum Radiation Cooling LIGO-T C R. Abbott, S. Waldman, Caltech 12 March, 2007

Thermal design of the CFRP support struts for the spatial framework of the Herschel Space Observatory

Mechanisms of heat transfer

On the Emissivity of Silver Coated Panels, Effect of Long Term Stability and Effect of Coating Thickness

National Superconducting Cyclotron Laboratory Michigan State University, East Lansing, Michigan, 48823, USA

Superfluid helium and cryogenic noble gases as stopping media for ion catchers Purushothaman, Sivaji

Introduction to Blackbody Sources

Thermal sensitive foils in physics experiments

AQA GCSE Physics 9-1 Required Practicals Revision Booklet Name

EFFECT OF XENON GAS AND FOILS ON A MULTI-FOIL INSULATION

EXPERIMENT NO. 4. Thermal Radiation: the Stefan-Boltzmann Law

Thermal Sensors and Actuators

INFLUENCE OF SURFACE EMISSIVITY AND OF LOW EMISSIVITY SHIELDS ON THE THERMAL PROPERTIES OF LOW DENSITY INSULATING MATERIALS

An Improved Formulation for Calorimetric Emittance Testing. of Spacecraft Thermal Control Coatings

Supplemental Information. Storage and Recycling of Interfacial. Solar Steam Enthalpy

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Heriot-Watt University

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

Feasibility of HTS DC Cables on Board a Ship

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors I

Gesellschaft für Schwerionenforschung mbh (GSI), Planckstrasse 1, D Darmstadt, Germany

arxiv: v1 [physics.ins-det] 6 Nov 2007

Low Vibration Cryogenic Equipment

Padua, Italy. Theoretical competition

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

Cryogenic Instrumentation I Thermometry OUTLINE Thermometry Pt (pure metal) Temperature Ranges of Thermometer Application Typical Resistive Thermal

Which picture shows the larger flux of blue circles?

Apparatus to measure high-temperature thermal conductivity and thermoelectric power of small specimens

HIMARC Simulations Divergent Thinking, Convergent Engineering

Improvements of a Thermal Method for the Determination of Solar Absorptance and Thermal Emittance of Spacecraft Coatings

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Microscopy Cryostat System

MEASUREMENT OF TOTAL HEMISPHERICAL EMISSIVITY USING A CALORIMETRIC TECHNIQUE. J Hameury, B Hay, J-R Filtz

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

PROBLEM 1.3. dt T1 T dx L 0.30 m

UNIT FOUR SOLAR COLLECTORS

Ir TES electron-phonon thermal conductance and single photon detection

DIRECT RADIOMETRIC TECHNIQUES

Measurements of temperature on LHC thermal models

Calibrating the Thermal Camera

CB FDHMT. Contract No GSI Helmholzzentrum für Schwerionenforschung GmbH Planckstraße Darmstadt. 15. December /11

YJ-BC-270H-G01 High CRI LED

UNIVERSITY OF WATERLOO. ECE 309 Thermodynamics and Heat Transfer. Final Examination Spring 1997

MARYLAND. Fundamentals of heat transfer Radiative equilibrium Surface properties Non-ideal effects. Conduction Thermal system components

Diffuse Thermal Radiation Focusing Device

Newsletter 1/2014. Super-polished copper a new substrate material. Fabrication of neutron collimators launched

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

Simultaneous Conduction and Radiation Energy Transfer

FIND: (a) Sketch temperature distribution, T(x,t), (b) Sketch the heat flux at the outer surface, q L,t as a function of time.

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

He II Heat transfer through a Corrugated Tube - Test Report

Introduction to Infrared Radiation.

Radiation Heat Transfer. Introduction. Blackbody Radiation. Definitions ,

Coolant. Circuits Chip

Reversible Processes. Furthermore, there must be no friction (i.e. mechanical energy loss) or turbulence i.e. it must be infinitely slow.

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

Vacuum techniques (down to 1 K)

INFRAMET. 2.1 Basic laws

Cryogenic Emissivity Calibration of Highly Reflective Materials

A TES Bolometer for THz FT-Spectroscopy

HEAT AND THERMODYNAMICS

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

Handout 10: Heat and heat transfer. Heat capacity

Analysis of Thermal Diffusivity of Metals using Lock-in Thermography

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Heat Sinks and Component Temperature Control

CHAPTER V. Thermal properties of materials at low temperatures

Thermal Interface Material Performance Measurement

Lecture 36: Temperatue Measurements

Friction and Elongation of Al Electrodes due to Micro-Sliding between the Inner Mo Electrode and the Al Electrodes in High-Power Devices

Thermal Radiation By: Prof. K M Joshi

Heat and Mass Transfer Unit-1 Conduction

PURE PHYSICS THERMAL PHYSICS (PART I)

SUPER-INSULATED LONG-TERM HOT WATER STORAGE

Heat Transfer. Phys101 Lectures 33, 34. Key points: Heat as Energy Transfer Specific Heat Heat Transfer: Conduction, Convection, Radiation.

Maximum Heat Transfer Density From Finned Tubes Cooled By Natural Convection

Measurement of small sample thermal conductivity by parallel thermal conductance technique

Autumn 2005 THERMODYNAMICS. Time: 3 Hours

Radiative Equilibrium Models. Solar radiation reflected by the earth back to space. Solar radiation absorbed by the earth

Temperature Measurement

Div. 1 Div. 2 Div. 3 Div.4 8:30 am 9:30 pm 12:30 pm 3:30 pm Han Xu Ruan Pan

Lecture Outline. Energy 9/25/12

Thermal characteristic evaluation system to evaluate. heat transfer characteristics of mounted materials

A PHOTON-STOP FOR THE VLHC-2 ENGINEERING DESIGN PART 1

Radiative heat transfer

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Total hemispherical emissivity of glass sheets with different thicknesses measured by a transient calorimetric technique

Thermal Systems Design MARYLAND. Fundamentals of heat transfer Radiative equilibrium Surface properties Non-ideal effects

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Uncertainty Workshop: Overview of uncertainty factors in HTGHPs

Cryogenics for bolometric interferometry: The BRAIN experiment

Chapter 1 Heating Processes

Thermal analysis of superconducting undulator cryomodules

Transcription:

DEVICE FOR MEASUREMENT OF THERMAL EMISSIVITY AT CRYOGENIC TEMPERATURES Tomas Kralik, Pavel Hanzelka, Vera Musilova, Ales Srnka Institute of Scientific Instruments ASCR, Kralovopolska 47, Brno, CZ 62 64, Czech Republic email: kralik@isibrno.cz ABSTRACT In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for the range of the temperature of the radiating surface 25 K-50 K are possible. The absorbing surface has a temperature between 5 K and 0 K when LHe is used as cryoliquid. The desired measurement sensitivity is mk for temperature and 0. µw for heat power, respectively. The diameter of the whole device is 50 mm and so it is possible to use a commercial dewar can for the cooling. The form of the sample is a round plate 40 mm in diameter and mm in thickness with one tested side. The emissivity and its temperature dependency for various surface treatments can be checked immediately before application in a cryogenic system.. INTRODUCTION The knowledge of thermal radiative properties of surfaces is important for design of low temperature apparatuses. Our Laboratory of cryogenics needs these values for designing and construction of various experimental cryostats and applications. Existing published data are often not sufficiently useable. Most data are obtained at a sample temperature of 4.2 K, 77 K and 300 K and a temperature of radiation of 77 K and 300 K (Scott, 959, Kaganer, 969). Very little experimental data about temperature dependency exist. It is possible to found some spectral data (Biondi and Guobadia, 968, Bos and Lynch, 970, Tsujimoto et al., 982) for samples at 4 K. 2. THE MUTUAL EMISSIVITY For the measurement of the radiative heat transfer between two parallel surfaces (radiator and absorber) under cryogenic conditions a new apparatus was developed at ISI Brno. It is possible to vary a temperature of the radiator T R and the absorber T A. The measurement is based on the detection of the radiative heat flux Q R absorbed by the absorber and on calculation of the mutual emissivityε by (). RA Q ε RA = () A σ ( T T ) R 4 R A is an area of the absorber (equal to the radiator area), σ is the Stefan-Boltzmann-constant. If radiative properties do not depend on the wavelength of thermal radiation, the mutual emissivity of two parallel surfaces may be calculated (2) from the total hemispherical emisivity ε ( T R ) of the hot surface and total hemispherical absorptivity α T, T of the cold surface. = ε + ( A ) (2) ε RA If the emissivity ε ( T R ) of a radiator (e.g. metallic surface) is very small in comparison to the R α 4 A

absorptivity α ( T, T ) R A of an absorber surface, the measured mutual emissivity is approximately equal to the emissivity of the radiator. In such a configuration total hemispherical emissivity of metallic surface may be measured. And vice versa, when metallic sample is in the position of the absorber, its total hemispherical absorptivity is measured. 3. DESCRIPTION OF THE APPARATUS The isothermal measuring chamber (IMC, Figure ) is placed in the evacuated stainless steel casing tube (SCT) of a diameter of 48 mm. The length of the whole apparatus is about m. This form allows the cooling by using of a commercial dewar with a neck diameter of 50 mm. Figure - Bottom part of the apparatus Left: D,D2,D3 - diodes (Lake Shore DT 470), D4 - diode (Lake Shore DT-470) as microwatt heater Q HA, A - absorber, AH absorber holder, R-radiator, RH radiator holder, RWH resistive wire heater Q HR, STR stainless steel thermal resistor, FGI - fibre glass insulator, IMC isothermal measuring chamber, SCT evacuated stainless steel casing tube Right: RS radiation shield, TS thermal switch, CCS charcoal sorbent The bottom of the casing tube (CT) is welded together with the stainless plug (SP). Copper thermal contact (CTC) with a thread is soldered in this plug. The thread thermally joins the measuring chamber with the thermal contact and so with the cryoliquid in the dewar. The plug contains a small chamber with charcoal sorbent (CCS). The whole measuring chamber is mounted to the holding tube (HT). Electrical contacts and wires are fixed to this tube. Four radiation shields (RS) attached

to the holding tube support the thin casing tube against surrounding pressure. Each shield is cooled by friction contact with the casing tube. An actuating tube of thermal switch (TS) leads through the holding tube. The upper end of the casing tube is terminated with a pot covered by an O-ring sealed plate. The plate is equipped with three welded vacuum connectors and a thermal switch actuator. The radiator (R) and the absorber (A) (both diam. 40 mm, thick. mm) are situated in the measuring chamber (IMC). Between the absorber and the radiator is a gap of about 0.5 mm. The radiator is attached to the radiator holder (RH) heated by a resistance wire heater (RWH). The radiator holder is linked with the top of the measuring chamber by a thermal insulator (TIF) made of thin fibreglass tube. The absorber is attached to the absorber holder (AH) heated by a microwatt calibration heater. Diode D4 Lake Shore DT 470 is used as this heater. The thermal contact is improved by Apiezon grease (Gmelin, 999). The holder of the absorber is linked to the bottom of the measuring chamber by the thermal resistor (STR) made of a thin stainless steel tube. The inner sides of the measuring chamber are coated with an epoxy layer. This black layer inhibits multiple reflections of thermal radiation coming from the backside of the radiator and prevents this parasitic heat from penetration into the gap between the radiator and absorber. For the measurement of temperatures T A (absorber), T R (radiator) and T K (chamber bottom) three calibrated silicon diodes (D, D2, D3) Lake Shore DT 470 are used. 4. MEASUREMENT PROCESS Evacuated apparatus is firstly cooled down in LN 2 (30 min) and then it is inserted in the LHe dewar. The cool-down process of the whole apparatus in LHe takes about 8 hours and is carried out overnight. Slow heat transfer from the absorber through thermal resistor determines the time of cooling. The thermal switch accelerates cooling of the radiator. Constant temperature of LHe bath (Hanzelka and Musilova, 995) is ensured by a pressure stabilizer (Hanzelka and Jura, 2002). The main principle of the measurement method is substitution of the radiative heat flow Q R by the electric power Q HA. For this purpose the calibration of thermal resistor is performed, i.e. the dependence Q HA (T A -T K ) is found. The radiator has the temperature of the chamber during calibration. The heat radiated from the backside of the absorber is negligible in comparison with conductive heat flow. Then the emisivity measurement follows. The radiator temperature T R is adjusted by heating with Q HR and absorber temperature T A is measured after reaching its equilibrium value. Radiative heat flow Q R is calculated from the calibration Q HA (T A -T K ) and gradient T A -T K. The relation () gives mutual emissivity value. If an elevated temperature of the absorber is required during the emissivity measurement, an additional heat flow produced by Q HA is applied. The temperatures T A and T K are detected with a sensitivity of mk. This sensitivity enables measurement of radiative heat flows as low as 0. µw. Some amount of the radiative heat flow Q R leaks out from the gap between the absorber and radiator. Our measurements for the same sample and variable gap show that the error of the emissivity caused by this leak of the radiation is not greater than 0 % if the gap width is maximally mm. This error is systematic and can be corrected. Usually a gap of 0.5 mm was adjusted. 5. EXPERIMENTAL RESULTS At this time our configuration allows measurement of absorptivity of metals. A copper plate covered by epoxy layer 60 µm thick is used as the radiator. This layer does not represent a perfect black body surface. The mutual emissivity of two epoxy surfaces at T A =5.5 K and T R =30.4 K

is 34 %. But this epoxy blackness insures that small values of mutual emissivity of the sample - epoxy configuration are with high accuracy identical to the value of sample absorptivity. For example, a mutual emissivity of 5% corresponds to a sample absorptivity of 5.05%. For the samples with higher absorptivity the measured value of mutual emissivity must be recalculated. 5. TESTS OF THE METHOD The method was tested by the following experiment. We measured absorptivity of a chemically polished copper first. Then we made an epoxy spot (.4 % of the sample area, 70 µm thick) on the sample surface and the apparent absorptivity of the sample was measured again. The last step was the measurement of the mutual emissivity of two epoxy surfaces. The apparent absorptivity of the surface with the spot was predicted by two models. The first one supposed the influence of the spot on the radiation density in the gap. The second one omitted this influence. The measured apparent absorptivity of the surface with the spot lies between predictions of both models (Figure 2). 2.0.8.6 Cu with epoxy spot (model 2).4 ε 2 [%].2.0 0.8 Cu with epoxy spot (model ) Cu with epoxy spot (measured) 0.6 0.4 Blank Cu surface (measured) 0.2 20 30 40 50 60 70 80 90 00 Figure 2 - Test of the method Radiator temperature [K] To verify the correspondence of our results with published data, the measurement of Al (purity 99.5 %) at 5 K was compared with (Biondi and Guobadia, 968, Bos and Lynch, 970, Tsujimoto et. al., 982, Ramanathan, 952). Open symbols are used for optical (spectral) measurements and the filled ones for the thermal measurements plotted in Figure 3.

In the case of thermal measurements the temperature T R was converted to the wavelength by means of Wien s displacement law: 3000 λ max = [µm; K] (3) T R It can be proved for metals at low temperatures and far infrared radiation that the value of total hemispherical absorptivity is near to the value of spectral normal absorptivity measured at this wavelength. O 0 Bos, 970 Biondi, 968 Tsujimoto, 982 Ramanathan, 952 ISI Brno, 2003 α λ, ε 2 [%] 0. 0 00 λ [µm] Figure 3 - absorptivity of aluminum at 4 K-5 K 5.2 EXAMPLES OF MEASUREMENTS In Figure4 the experimental results of measuring of super insulation foils and an Al wrapping foil are shown. Foils were glued on a black epoxy surface. The firm Austrian Aerospace provided us with the first four foils listed in the legend of Figure 4. The samples Nr. 25 and Nr. K 73 are 6 µm polyester foils one side aluminized with a square resistance of 0.07-0.029 ohm/sq and double side aluminized with a square resistance of 0.5-0.7 ohm/sq., respectively. Nr. K 76 is a 2 µm polyester foil, double side aluminized, with a square resistance of 0.5-0.8 ohm/sq. The 9 µm aluminium foil of 99.5% purity, shiny surface with 0.0-0.02 ohm/sq., is labelled Nr. K 6. Furthermore, the absorptivity of the shiny and mat face of the wrapping foil was measured.

.6.4.2.0 ε 2 [%] 0.8 0.6 0.4 0.2 0.0 0 20 30 40 50 60 70 80 90 00 0 20 30 40 Radiator temperature [K] Figure 4 - emissivity of some superinsulation foils and Al-foils AAE-Colli Nr.: 25 AAE-Colli Nr.: K73 AAE-Colli Nr.: K76 AAE-Colli Nr.: K6, shiny Al wrapping foil, shiny face Al wrapping foil, mat face CONCLUSIONS An apparatus for measurement of emissivity and absorptivity of material surfaces at cryogenic conditions was developed. In contradistinction to most of published data, temperature dependences of absorptivity were obtained at experiments. The device sensitivity enables the measurement of absorptivity above the value of 0.3 % when the sample is irradiated by a heat emitted from a black surface at 25 K. It is possible to use a commercial dewar can for the apparatus cooling. The advantage of the device is easy preparation of the samples. Measurement of one temperature dependence takes one day. Nowadays common cryogenic materials with various surface treatments are continuously measured (Musilova et. al., 2004). The measurements are very well reproducible. The application of this apparatus helps to extend the knowledge about radiative properties of materials and their temperature dependence. ACKNOWLEDGEMENT This work is supported by the Academy of Sciences of the Czech Republic, the projects No. IBS206509 and No. KSK 206707. We would like to thank the firm Austrian Aerospace GmbH for sending of samples of superinsulation foils.

REFERENCES. Amano, T., Ohara, A., 99, An experimental study of thermal radiation at cryogenic temperatures, Heat Transfer-Japanese Research, vol. 20, p. 307-323 2. Biondi M., A., Guobadia A. I., 968, Infrared Absorption of Aluminum, Copper, Lead and Nickel at 4.2 K, Phys. Rev., vol. 66, p. 667-673 3. Bos L. W., Lynch D. W.,970, Low energy optical absorption peak in aluminum and Al- Mg alloys, Phys. Rev. Lett., vol. 25, p. 56-58 4. Gmelin, E., Asen-Palmer, M., Reuther, M., Willar, R., 999, Thermal boundary resistance of mechanical contacts between solids at sub-ambient temperatures, J. Phys. D: Appl. Phys., vol. 32, p. 9-43 5. Hanzelka, P., Musilova, V., 995, Influence of changes in atmospheric pressure on evaporation rates of low-loss helium cryostats, Cryogenics, vol. 35, no 3, p. 25-28 6. Hanzelka, P., Jura, P., 2002, Fuzzy pressure controller for helium bath cryostats, Proc.7 th IIR Int. Conf. CRYOGENICS 2002, Praha, p. 53-56. 7. Kaganer, M. G.,969, Thermal Insulation in Cryogenic Engineering, IPST, Ltd., Jerusalem, 220 p. 8. Musilova, V., Hanzelka, P., Kralik, T., Srnka, A., 2004, Low Temperature Emissivity of Metals Used in Cryogenics, Proc.8 th IIR Int. Conf. CRYOGENICS 2004, Praha, (this Proceedings) 9. Ramanathan, K.G., 952, Infra-Red Absorption by Metals at Low Temperatures, Proc. Phys. Soc. London A65, p. 532-540 0. Scott, R. B., 959, Cryogenic Engineering, New York, 368 p.. Tsujimoto, S., Kanda, M., Kunimoto, T., 982, Thermal properties of some cryogenic materials, Cryogenics, vol. 22, p. 59-597