(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Similar documents
Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

TANDEM MASS SPECTROSCOPY

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

MS Goals and Applications. MS Goals and Applications

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

Types of Analyzers: Quadrupole: mass filter -part1

Mass Spectrometry. What is Mass Spectrometry?

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Analysis of Polar Metabolites using Mass Spectrometry

Introduction to LC-MS

MS Goals and Applications. MS Goals and Applications

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Mass spectrometry gas phase transfer and instrumentation

Chemistry 311: Topic 3 - Mass Spectrometry

LC-MS Based Metabolomics

MASS SPECTROMETRY. Topics

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

This is the total charge on an ion divided by the elementary charge (e).

Mass Spectrometry in MCAL

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

MS/MS .LQGVRI0606([SHULPHQWV

Translational Biomarker Core

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Introduction to the Q Trap LC/MS/MS System

Computational Methods for Mass Spectrometry Proteomics

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

BST 226 Statistical Methods for Bioinformatics David M. Rocke. January 22, 2014 BST 226 Statistical Methods for Bioinformatics 1

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Time-of-Flight Mass Analyzers

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

Mass spectrometry.

Harris: Quantitative Chemical Analysis, Eight Edition

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

CHROMATOGRAPHY AND MASS SPECTROMETER

Molecular Mass Spectrometry

BIOINF 4399B Computational Proteomics and Metabolomics

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Mass spectrometry has been used a lot in biology since the late 1950 s. However it really came into play in the late 1980 s once methods were

1 Mass Analysis. Gene Hart-Smith and Stephen J. Blanksby

Mass Spectrometry Course

Chem 550, Spring, 2012 Part I: OVERVIEW OF MASS SPECTROMETRY:

CHAPTER D3 TOF ION OPTICS

Introduction to Mass Spectrometry

1. The range of frequencies that a measurement is sensitive to is called the frequency

Basics of Mass Spectrometry

Choosing the metabolomics platform

Chemistry Instrumental Analysis Lecture 37. Chem 4631

PC 235: Mass Spectrometry and Proteomics

Selecting and planning for the right mass spectrometer

What is a mass spectrum?

Università degli Studi di Bari CHIMICA ANALITICA STRUMENTALE

Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry

Ionization Techniques Part IV

Auxiliary Techniques Soft ionization methods

Temperature-Programmed Desorption

Molecular Mass Spectrometry

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Secondary Ion Mass Spectroscopy (SIMS)

Mass Spectrometry. A truly interdisciplinary and versatile analytical method

Tendenze nell innovazione della strumentazione in spettrometria di massa:

MS-based proteomics to investigate proteins and their modifications

Lecture 15: Introduction to mass spectrometry-i

Mass Spectrometry for Chemists and Biochemists

Table of Contents... XI

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

L. Seda Mut Neslihan Ötük

Thermo Finnigan LTQ. Specifications

Qualitative Organic Analysis CH 351 Mass Spectrometry

Temperature-Programmed Desorption. C-874 University of Delaware

BIOINF 4120 Bioinformatics 2 - Structures and Systems - Oliver Kohlbacher Summer Systems Biology Exp. Methods

ICPMS Doherty Lecture 1

Protein analysis using mass spectrometry

Mass Spectrometry. General Principles

Secondary Ion Mass Spectrometry (SIMS)

2. Separate the ions based on their mass to charge (m/e) ratio. 3. Measure the relative abundance of the ions that are produced

History of Mass spectroscopy. Mass Spectroscopy. Introduction... Uses of Mass Spec. Where are Mass Spectrometers Used? Mass Spectroscopy Units

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Mass Analysers for LC MS

Transcription:

(Refer Slide Time 00:09) Mass Spectrometry Based Proteomics Professor Sanjeeva Srivastava Department of Biosciences and Bioengineering Indian Institute of Technology, Bombay Mod 02 Lecture Number 09 (Refer Slide Time 00:13)

(Refer Slide Time 00:16) (Refer Slide Time 00:20) Mass spectrometry is a technique for protein identification and analysis by production of charged molecular species in vacuum and its separation by magnetic and electric fields based on its mass to charge ratio. Mass spectrometry has become the method of choice for analysis of complex protein samples in proteomics studies due to its ability to identify thousands of proteins.

(Refer Slide Time 00:58) The ionization source is responsible for converting analyte molecules into gas phase ions in vacuum. This has been made possible by the development of soft ionization techniques (Refer Slide Time 01:12) which ensure that the non-volatile protein sample is ionized without completely fragmenting it. Most commonly used ionization sources are MALDI and ESI.

(Refer Slide Time 01:31) Additionally, there are other ionization sources such as Fast Atom Bombardment FAB, Laser Desorption LD, Plasma Desorption PD. We discussed the two most commonly used soft ionization techniques MALDI and ESI. (Refer Slide Time 01:49)

(Refer Slide Time 01:55) The mass analyzer disperses all the ions based on their mass to charge ratio and focuses all the mass-resolved ions at a single focal point and maximizes their transmission. (Refer Slide Time 02:13) The Time of flight: measures m by z ratio

(Refer Slide Time 02:17) of ions based on (Refer Slide Time 02:20) the time it takes for ions to fly in the analyzer and strike to the detector.

(Refer Slide Time 02:30) The Ion Trap: it traps ions using electrical fields (Refer Slide Time 02:36) and

(Refer Slide Time 02:37) measures mass (Refer Slide Time 02:38) by selectively ejecting them

(Refer Slide Time 02:42) to the detector. (Refer Slide Time 02:46) Quadrupole: it consists of

(Refer Slide Time 02:48) 4 parallel (Refer Slide Time 02:49) metal rods

(Refer Slide Time 02:50) and mass separation is (Refer Slide Time 02:53) accomplished by the stable vibratory motion

(Refer Slide Time 02:57) of ions in high frequency (Refer Slide Time 03:01) oscillating electric field that is created by applying direct current and radio frequency potentials to these electrodes.

(Refer Slide Time 03:14) (Refer Slide Time 03:18) There are different types of mass spectrometers currently available but for proteomics there are 2 configurations which are most commonly or most oftenly used; the Quadrupole-Time of Flight or Q-TOF-based configurations and hybrid linear Ion Orbitrap instruments. The TOF configurations separate peptides in time as they reach on the detector, so the time of flight is measured, whereas in the Orbitrap mass analyzers, they measure the frequency of peptide ions which are oscillating in the ion trap. Now different types of resolutions and sensitivity can be obtained from each of these configurations.

(Refer Slide Time 04:10) In the previous lecture, I gave you an overview of the different types of mass analyzers currently available. Each of those has its own unique properties in mass range, analysis speed, resolution, sensitivity, the ion transmission and dynamic range. The Time of Flight analyzers use time flight. Ion Trap, Orbitrap and Ion Cyclotron Resonance separate ions based on their mass to charge resonance frequency, whereas the quadrupoles or Q use an oscillating electrical field for selective stabilization of ions. This just gives you an overview of various types of mass analyzers and briefly we discussed about their principle. (Refer Slide Time 05:06)

Now mass analyzers can be categorized broadly into the scanning MS, ion-beam MS and trapping MS. Scanning MS is more commonly used with TOF which is further coupled with the MALDI ionization sources. The ion-beam MS is commonly used for the quadrupoles, whereas, trapping MS for the ion traps, Orbitrap and FT-ICR. All these can be coupled with the Electrospray Ionization ESI. Some of the important mass analyzers, lets discuss a little more in detail. (Refer Slide Time 05:50) First, talking about Time Of Flight, which is one of the simplest mass analyzers currently used in combination with the MALDI. The TOF has emerged as one of the mainstream techniques for the analysis of biomolecules and it is widely used for various applications.

(Refer Slide Time 06:12) In TOF, the ions are accelerated to high kinetic energy and due to their different velocities, they are separated in a flight tube. One can also use the reflectron mirror so that ions can turn around into a reflector and it compensates for minor differences in the kinetic energy and provides long separation. Another commonly used mass analyzer is Quadrupole. (Refer Slide Time 06:44) The Q instruments are one of the most widely used type of mass analyzers currently used in proteomics.

It consists of four matched parallel metal rods and mass separation is accomplished by the stable vibratory motion of ions in a high-frequency oscillating electric field that is created by applying direct current and radio frequency potentials to these electrodes. (Refer Slide Time 07:19) So, as we talked, quadrupole is a set of 4 parallel metallic rods with opposite pairs electrically connected. There are different modes one can use for this analysis- RF or radio frequency mode: which allows ions of any m by z ratio to pass though Scanning mode: ions of selected mass and charge can be allowed by the detector. The potential difference applied in the instrument can be used as the mass filter. The neutral loss scan and precursor ion scanning method: they are used for the phosphorylation to distinguish between phosphorylated and non-phosphorylated peptides.

(Refer Slide Time 08:10) Now triple quads, which is an arrangement of quadrupoles is widely used for proteomics. In triple quad, Q1 casts the ionic streams. It directs ions of a selected m by z ratio into the second quadrupole, Q2, which is a collision cell. As you can see in this slide, the collision cell operates in the radio frequency mode. The fragmentation of intact peptide ions can be induced by collision with inert gases and then selected ions are further moved into the Q3. Q3 scans the streams of ion fragments which are emerging from the collision cell to generate a collision induced disassociation spectrum. The mass spectrum of fragments derived from one peptide after one analysis is complete. Then Q1 directs a different intact peptide into the collision cell. So, in this sequential manner, it can process various peptides.

(Refer Slide Time 09:27) Now let s talk about another important mass analyzer, the Ion Trap. The Ion Trap traps ions using electrical fields and it measures by selectively ejecting them to a detector. (Refer Slide Time 09:44) It consists of a chamber which is surrounded by a ring electrode and two end-cap electrodes, as you can see in the figure here. The voltage applied to the ring electrode determines which ions remain inside the trap. So, ions above a threshold of m by z ratio remain inside the trap and others can be ejected through a small hole. Theoretically ion trap can provide MS analysis and it can also provide a mass filter.

(Refer Slide Time 10:28) One important mass analyzer is Fourier Transform Ion Cyclotron Resonance or FT-ICR. Due to its high resolution and MS/MS capabilities, application of FT-ICR MS in combination with ElectroSpray Ionization has been employed for large biomolecules and now it is also used in proteomics. (Refer Slide Time 10:53) An FT-ICR MS can be considered as ion trap system, where ions are trapped in the magnetic field. It uses cyclotron motion or cyclotron frequency to resolve the ions. Although operationally it is very complex and not very easy to operate; but it provides highest resolution, mass accuracy and sensitivity. It also provides the capability of multiple tandem experiments and MS/MS of very large ions is possible by using FT-ICR MS.

(Refer Slide Time 11:35) (Refer Slide Time 11:39)

(Refer Slide Time 11:43) So, the TOF mass analyzers consist of ion acceleration and focusing optics and a flight tube. As shown in the slide, you have a source, sample ionization is occurring due to the laser beam bombardment, then ions are moving in the Time of Flight tube and reaching towards the detector. Now often, we can also add the reflector, an ion mirror which can increase the path length. So, this Time of flight tube measures the mass to charge ratio of ions based on the time it takes for ions to fly in the analyzer and strike to the detector. The mass is exponentially proportional to the flight time, how much time it takes to travel in the Time of Flight tube. So, ions of the lower masses are accelerated to higher velocities. Now Time of Flight tubes often out-performs the scanning mass analyzers in its sensitivity and scan speed.

(Refer Slide Time 12:56) The Time of Flight of a charged ion can be calculated by using the equation shown in this slide; the flight time is directly proportional to the square root of mass of the ion. Now in this equation, "t" represents the time of flight, "m" is mass of the ion, 'q" charge on the ion, "V zero" is accelerating potential and "l" is the length of flight tube. (Refer Slide Time 13:27)

In time of flight tube, the ions are accelerated to high kinetic energy, and due to different velocities, they are separated in a flight tube. As I mentioned earlier, by adding the reflectron or a reflector, the ions can turn around in the reflector that can compensate for minor differences in the kinetic energy. Now if you take an example where you have 3 ions as shown, the dark blue, light blue and the red color in the slide, now you will expect the small ion which is the red one to show the first peak, followed by the blue ion and then the dark blue ion. After discussing some of these basic concepts of using MALDI and TOF, (Refer Slide Time 14:22) now let me give you an overview of entire MALDI-TOF experiment by showing you the following animation. (Refer Slide Time 14:31)

Fundamentals of MALDI-TOF MS :

(Refer Slide Time 14:38) The Time of Flight analyzer resolves ions, produced by (Refer Slide Time 14:42) the ionization source, on the basis of their mass to charge ratio. The time of flight tube can be operated in the linear mode

(Refer Slide Time 14:53) or the reflectron mode which depends on the sample to be analyzed. In case of small molecules this mode usually provides sufficient resolution. (Refer Slide Time 15:09) The generated ions are accelerated

(Refer Slide Time 15:12) towards the detector, with the lighter (Refer Slide Time 15:15) travelling through the TOF tube faster than

(Refer Slide Time 15:20) the heavier ions. So, the lighter ion travels faster and it strikes the detector before the heavier ion reaches to the detector. The Time Of Flight or the TOF tube can be correlated to the mass of the ion. So, the time of flight of the ions can be correlated with the mass to charge ratio. As we talked earlier the TOF analyzer can also be operated in the reflectron mode. (Refer Slide Time 15:54) So, this is more commonly used for the proteomic studies.

(Refer Slide Time 15:58) A reflectron, which acts as an ion mirror, is incorporated at one end of the time of flight tube. (Refer Slide Time 16:05) This helps in extending the path length

(Refer Slide Time 16:16) and in turn (Refer Slide Time 16:19) the flight time of the ion without having to increase the

(Refer Slide Time 16:23) actual size of the instrument. (Refer Slide Time 16:27) So, rather than using very long time of flight tubes, by including the reflectron ion mirrors, we can increase the path length. This helps to even out any kinetic energy differences between ions having the same mass and thereby improving the resolution.

(Refer Slide Time 16:57) The time of flight of a charged ion can be calculated by means of the equation shown here. The flight time is directly proportional to the square root of mass of the ion. (Refer Slide Time 17:12) So, we have discussed all the important components of liquid chromatography mass spectrometry. Now, one can apply these configurations in tandem. One can select different types of mass analyzers and use it based on their applications. So, now we will look at some of the popular Hybrid-MS and MS/MS configurations.

(Refer Slide Time 17:15) (Refer Slide Time 17:43) MALDI TOF-TOF: that is one of the widely used tandem-ms configuration. In this one the TOF-TOF or two time-of-flight tubes as well hybrid quadrupole time-of-flight analyzers can be used. We have discussed the MALDI TOF-TOF system in some more detail in the previous lecture. So, I will move on to some other configurations which is (Refer Slide Time 18:16)

Q-TOF. The Q-TOF: it combines front part with quadrupole or triple quad TQ, along with the TOF analyzers to measure the mass of ion. (Refer Slide Time 18:32) Some of the important concepts involved in ionization, mass analyzers and tandem-ms

(Refer Slide Time 18:41), I will describe in the following animation. (Refer Slide Time 18:49) The triple quadrupole consists of two sets of parallel metallic rods interspersed by a collision cell. The first quadrupole scans the ions coming from the ionization source and allows only ions of a particular m by z ratio to pass through.

(Refer Slide Time 19:22) Once the ions are selected, (Refer Slide Time 19:24) ions enter the collision cell, where they are fragmented by collision against an inert gas, like argon. The smaller fragments then enter the third quadrupole, which scans all the ions in

(Refer Slide Time 19:46) the radio frequency or RF mode (Refer Slide Time 19:49) to generate a spectrum

(Refer Slide Time 19:52) based on the varying behavior of ions in an oscillating electrical field. (Refer Slide Time 19:55) There are different types of tandem MS/MS configurations such as

(Refer Slide Time 20:06) MALDI-TOF-TOF. MALDI-TOF-TOF MS is a common tandem MS configuration in which the ions are first resolved on the basis of their time of flight in the first TOF analyzer. (Refer Slide Time 20:23) The selected ions enter the collision cells where they are further fragmented.

(Refer Slide Time 20:33) (Refer Slide Time 20:34) The fragmented ions are accelerated

(Refer Slide Time 20:38) and further resolved on the basis of their m by z values in the second Time Of Flight tube, after which they can be detected. (Refer Slide Time 20:52)

(Refer Slide Time 21:04) ESI Q-TOF is another common tandem MS configuration that first selects ions in the radio frequency mode. (Refer Slide Time 21:14)

(Refer Slide Time 21:19) Selected peptides are fragmented in collision cells and resulting ions are accelerated and resolved on the basis of their time of flight. (Refer Slide Time 21:32)

(Refer Slide Time 21:35) So finally, there are so many mass spectrometers currently available commercially. So now depending on individual s application, one can select different types of configurations. Based on an excellent review from Yates and colleagues, I provided this performance comparison of MS instruments in following slide. Here you can see the Linear Ion Traps or LIT or LTQs: they have resolution of 2000, mass accuracy 100 ppm, sensitivity femtomole and the scan rate is very fast. The triple quadrupoles or TQs: with resolution of 2000, mass accuracy 100 ppm, sensitivity in atomole and scan rate is moderate. The LTQ-Orbitraps: they can provide high resolution of 100,000, mass accuracy 2 ppm, sensitivity in femtomole and scan rate is moderate to low. LTQ-FT-ICR: they can provide very high resolution of 500,000, mass accuracy less than 2 ppm, sensitivity in femtomolar range, slow scan rate. The Quadrapole Time of Flight: they provide resolution more than 10,000, mass accuracy 2 to 5 ppm, sensitivity in atomole range and scan rate is moderate to fast.

(Refer Slide Time 23:24) (Refer Slide Time 23:28)