ICP-Mass Spectrometer

Similar documents
OES - Optical Emission Spectrometer 2000

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Element Cube Project (x2)

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Overview of X-Ray Fluorescence Analysis

Partial Energy Level Diagrams

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

The Periodic Table. Periodic Properties. Can you explain this graph? Valence Electrons. Valence Electrons. Paramagnetism

Nucleus. Electron Cloud

Introduction to GC/MS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

(C) Pavel Sedach and Prep101 1

Sample Analysis Design PART III

Trace Analyses in Metal Matrices Using the ELAN DRC II

Atoms and the Periodic Table

Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry: acquiring basic skills and solid sample meausurements

Last 4 Digits of USC ID:

ORBITAL DIAGRAM - A graphical representation of the quantum number "map" of electrons around an atom.

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important ones are...

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Analysis Repeatability of Trace and Major Elements in a Water Sample

Guide to the Extended Step-Pyramid Periodic Table

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

5 questions, 3 points each, 15 points total possible. 26 Fe Cu Ni Co Pd Ag Ru 101.

Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Sample Analysis Design PART II

Radiometric Dating (tap anywhere)

Use of a Novel Array Detector for the Direct Analysis of Solid Samples by Laser Ablation Inductively Coupled Plasma Sector-Field Mass Spectrometry

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Supporting Information. Facile design of phase separation for microfluidic. droplet-based liquid phase microextraction as a front end to

HANDOUT SET GENERAL CHEMISTRY II

Topic 3: Periodicity OBJECTIVES FOR TODAY: Fall in love with the Periodic Table, Interpret trends in atomic radii, ionic radii, ionization energies &

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Sample Analysis Design Polyatomic Interferences

ORBITAL DIAGRAM - A graphical representation of the quantum number "map" of electrons around an atom.

-"l" also contributes ENERGY. Higher values for "l" mean the electron has higher energy.

The exam must be written in ink. No calculators of any sort allowed. You have 2 hours to complete the exam. Periodic table 7 0

All chemical bonding is based on the following relationships of electrostatics: 2. Each period on the periodic table

610B Final Exam Cover Page

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

PERIODIC TABLE OF THE ELEMENTS

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

Laser Spectroscopy on Bunched Radioactive Ion Beams

CHEM 130 Exp. 8: Molecular Models

Grade 11 Science Practice Test

INSTRUCTIONS: CHEM Exam I. September 13, 1994 Lab Section

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

RITU and the GREAT Spectrometer

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

Unit 1 Part 2 Atomic Structure and The Periodic Table Introduction to the Periodic Table UNIT 1 ATOMIC STRUCTURE AND THE PERIODIC TABLE

Introduction to LIBS COMMUNITY USER WORKSHOP ON PLANETARY LIBS (CHEMCAM) DATA. Sam Clegg and the ChemCam team

History of the Periodic Table

PHYSICAL SCIENCES GRADE : 10

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

BROOKLYN COLLEGE Department of Chemistry. Chemistry 1 Second Lecture Exam Nov. 27, Name Page 1 of 5

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 4: Matter and materials 1

Environmental and Geological Applications of Instrumental Neutron Activation Analysis. Department Environmental, Earth, & Atmospheric Sciences

Example: Helium has an atomic number of 2. Every helium atom has two protons in its nucleus.

2 (27) 3 (26) 4 (21) 5 (18) 6 (8) Total (200) Periodic Table

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.


COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Give the number of protons, neutrons and electrons in this atom of aluminium. Why is aluminium positioned in Group 3 of the periodic table? ...

ICP/MS Multi-Element Standards

Reporting Category 1: Matter and Energy

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

... but using electron configurations to describe how aluminum bromide forms is a bit cumbersome! Can we simplify the picture a bit?

Earth Materials I Crystal Structures

Chapter 12 The Atom & Periodic Table- part 2

Lewis dot structures for molecules

Chem Exam 1. September 26, Dr. Susan E. Bates. Name 9:00 OR 10:00

Agilent Technologies at TIAFT 2013

high temp ( K) Chapter 20: Atomic Spectroscopy

Chapter 3: Elements and Compounds. 3.1 Elements

The Periodic Table of Elements

Chemistry 431 Practice Final Exam Fall Hours

Chapter 8: An Introduction to Optical Atomic Spectrometry

9/20/2017. Elements are Pure Substances that cannot be broken down into simpler substances by chemical change (contain Only One Type of Atom)

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Made the FIRST periodic table

INTRODUCTION TO MEASUREMENTS

Secondary Support Pack. be introduced to some of the different elements within the periodic table;

CHEM 10113, Quiz 5 October 26, 2011

What monitoring techniques are appropriate and effective for detecting CO2 migration in groundwater: isotope-based monitoring Philippe Négrel

Solutions and Ions. Pure Substances

Ion-beam techniques. Ion beam. Electrostatic Accelerators. Van de Graaff accelerator Pelletron Tandem Van de Graaff

8. Relax and do well.

02/05/09 Last 4 Digits of USC ID: Dr. Jessica Parr

Atomic weight: This is a decimal number, but for radioactive elements it is replaced with a number in parenthesis.

Transcription:

ICP-Mass Spectrometer

New Mass Spectrometers

The main issue: sequential vs. simultaneous Scanning, peak hopping are sequential Like viewing a photo through a peephole One pixel at a time Other parts of photo are invisible Even worse: viewing a movie through a peephole The most important parts always seem to be where you are NOT looking!

QuickTime and a decompressor are needed to see this picture.

Concept: Electronic Photoplate Truly simultaneous High spatial resolution Fast recording Direct integration Broad dynamic range Linear Stable; simple storage Immediate readout SSMS photoplate courtesy of D.W. Koppenaal

Mattauch-Herzog Mass Spectrograph Electrostatic Analyzer Ion Optics Magnetic Sector (1-10 KG) 80 cm Entrance Slit Extraction Optic Focal Plane Camera

QuickTime and a Cinepak decompressor are needed to see this picture.

New Multichannel Detector Faraday-strip detection One count per ion (no amplification) No thermionic emission No dynode statistics No dependence on ion mass Continuous integration and random access of m/z Nondestructive or destructive readout option Extended dynamic range; repetitive read

FPC-128 Multichannel Detector Time for one spectrum - 0.5 ms Reset FET 1000 ff Two gain levels Faraday Strip 45µ fingers 10 ff 1000 ff 0.16 V / e тidt OA Multiplexer 5µ spacing 10 ff 15.8 V / e 1 Vout = C x128

Data Acquisition DRO NDRO

Fingerboard

Fingerboard Channels

Put photo of ICP-ADAMS here FPC-128 Installed in MHMS FPC-128 Power Supplies

ICP-MHMS-FPC ICP FPC-128

Fixed Pattern Noise

Improved Resolution Operating Conditions Sample Intro. Laser Ablation Sample BNRM 44 (0.51% Mo) Integration Time 1 s MS Entrance Slit Width 100 µm 0.4 amu Resolution Peak Center 98.03 Peak Width 0.12 FWHM R = 817

Simultaneous Isotope monitoring Mass Resolution 203 Pb, 206Pb, 207Pb, 208Pb 204 Tl, 205Tl 203 204 205 206 207 208 145 µm wide pixels, 100 µm slit (old prototype detector with 32 pixels) 45 µm wide pixels, 100 µm slit (FPC 128) 45 µm wide pixels, 50 µm slit (FPC 128)

Limits of Detection (pptr) Element Li Be Mg Al V Cr Mn Fe Co Ni Cu Zn Ga As Se Sr FPC 0.97 2.4 0.24 0.44 7.1 3.6 0.66 0.084 0.53 1.1 0.17 0.35 0.71 8.6 1.3 1.3 SEM 0.21 1.5 0.20 0.25 0.44 0.20 0.23 0.25 0.43 0.49 0.33 0.44 0.16 2.6 3.0 0.11 Element Y Mo Ag Cd In Sn Sb Ba La Ce Ho W Ir Tl Bi U FPC 3.0 1.1 1.7 0.23 0.54 0.49 7.2 0.74 2.4 1.8 0.60 0.74 0.51 1.1 0.91 1.4 SEM 0.12 0.073 0.055 0.026 0.10 0.23 0.18 0.17 0.42 0.14 1.2 0.63 0.89 0.11 0.22 15 FPC 31-channel Focal-plane camera; SEM slit + single-channel electron multiplier

Elemental Analysis with the FPC Array Detector: Limits of Detection (ICP source) 209 209Bi Bi 203Tl 203 Tl Ir 186 186W W 165 165Ho Ho 193Ir 193 Limits of detection in the sub-part per trillion level for most elements 119 119Sn Sn 111 111Cd Cd Isotope 100Mo 100 Mo 8888Sr Sr 5555Mn Mn 5252Cr Cr V 4848Ti Ti 5151V 0 1 2 3 4 Limits of detection (part pert trillion) Values determined using continuous sample introduction via an ultrasonic nebulizer 10 s integration time

Isotope Ratio Accuracy Isotope Ratio Accuracy (% Error)* Isotope Ratio FPC-128 FPC-31 58 Ni/60Ni 4.3 2.1 88 Sr/86Sr 14 33 100 Mo/97Mo 7.3 6.6 114 Cd/112Cd 1.8 2.1 120 Sn/118Sn 2.9 0.43 121 Sb/123Sb 2.6 25 184 W/186W 10 3.5 193 Ir/191Ir 0.085 5.0 *No correction for mass bias

Isotope Ratio Accuracy Isotope Ratio Accuracy (% Error)* Isotope Ratio FPC-128 FPC-31 58 Ni/60Ni 4.3 2.1 88 Sr/86Sr 14 33 100 Mo/97Mo 7.3 6.6 114 Cd/112Cd 1.8 2.1 120 Sn/118Sn 2.9 0.43 121 Sb/123Sb 2.6 25 184 W/186W 10 3.5 193 Ir/191Ir 0.085 5.0 *No correction for mass bias

Isotope Ratio Accuracy Isotope Ratio Accuracy (% Error)* Isotope Ratio FPC-128 FPC-31 58 Ni/60Ni 4.3 2.1 88 Sr/86Sr 14 33 100 Mo/97Mo 7.3 6.6 114 Cd/112Cd 1.8 2.1 120 Sn/118Sn 2.9 0.43 121 Sb/123Sb 2.6 25 184 W/186W 10 3.5 193 Ir/191Ir 0.085 5.0 *No correction for mass bias

Isotope Ratio Accuracy Error Isotope Ratio Uncorrected Bias Corrected Sr/86Sr 14% 8% Mo/97Mo 11% 3% 4% 0.8% 120 5% 0.4% 121 5% 0.7% 4% 1% 3% 0.03% 88 100 114 Cd/112Cd Sn/118Sn Sb/123Sb 184 W/186W 193 Ir/191Ir

Isotope-Ratio Precision

Isotope Ratio Precision 0.007% RSD, 3 minute integration

Elemental Analysis with the FPC Array Detector: Linear Dynamic Range Linearity over 7 orders 1pptr to 50 ppm Pixel full well capacity: ~105 charges (low gain) ~107 charges (high gain) Signal time

Where speed & simultaneous measurement really matter High-precision isotope ratios Optimal internal standardization Situations where the signal shape is critical Flow injection Electrothermal (carbon-furnace) vaporization Time-varying signals (e.g. LC, GC, CE) Modulation methods Fast transients (e.g. laser ablation)

Where speed & simultaneous measurement really matter High-precision isotope ratios Optimal internal standardization Situations where the signal shape is critical Flow injection Electrothermal (carbon-furnace) vaporization Time-varying signals (e.g. LC, GC, CE) Modulation methods Fast transients (e.g. laser ablation)

ETV-ICP-ADAMS

Electrothermal Vaporization Sample Introduction To ICP Cleaning Ar sweep gas I Temperature ( C) 10000 Ashing 1000 Drying 100 Vaporization 10 0 10 20 30 40 50 60 70 80 90 100 Time (s)

Temporal Separation of Isobaric Interferences 1.5 ArO+ and Fe monitored at m/z = 56 during a full ETV cycle Signal 1.0 5 6 Fe + Ar O + 0.5 0.0 0 10 20 30 40 50 Time (sec) 60 70 80

Elimination of Isobaric Overlaps Through Temperature Program Necessary m/z Resolving Power: ~330,000 10 μl injection, 10 ppb Cd and In solution Temperature Program Dry: 100 C, 90s Ash: 250 C, 10s Atomize: 1700 C, 4s Ramp: 250 C/s

ETV Limits of Detection (pptr) Isotope FPC SEM Isotope FPC SEM V-51 7 0.4 Sn-120 0.5 0.2 Cr-53 4 0.2 Sb-123 7 0.2 Mn-55 0.7 0.2 Ba-138 0.7 0.2 Co-59 0.5 0.4 Ho-165 0.6 1 Ni-60 1 0.5 W-186 0.7 0.6 Zn-66 0.4 0.4 Ir-193 0.5 0.9 Sr-88 1 0.1 Tl-203 1 0.1 Ag-107 2 0.06 Bi-209 0.9 0.2 Cd-114 0.2 0.03 U-238 1 20 10 s Integration Time FPC Focalplane camera SEM Single channel Secondary Electron Multiplier

ETV-ICP-ADAMS 1 ppm Sr and 10 ppb Y 2 s integration time All pixels at low gain (Pixels collecting 88Sr signals saturate at high gain) Signal for Y collected at high gain

Where speed & simultaneity really matter High-precision isotope ratios Optimal internal standardization Situations where the signal shape is critical Flow injection Electrothermal vaporization Time-varying signals (e.g. LC, GC, CE) Modulation methods Fast transients (e.g. laser ablation)

Laser Ablation ICP-ADAMS Setup Mattauch-Herzog Mass Spectrograph Cetac LSX-200 ICP He Sweep Gas Ar Make-up Gas

LA LODs Steady state, single shot Element Steady State (ng/g) Single Shot (fg) Element Steady State (ng/g) Single Shot (fg) B 31 160 Sr 342 1770 Mn 51 261 Ag 15 76 Fe 36 186 Au 36 188 Co 41 210 Tl 10 50 Ni 41 216 Pb 9 46 Cu 31 163 Th 233 1200 Rb 112 577 U 53 272

Laser Ablation ICP-ADAMS Shot-to-Shot Reproducibility Isotope %RSD Isotope %RSD 27 Al 3.3 65 Cu 9.5 28 Si 7.4 93 Nb 8.4 52 Cr 11.3 100 Mo 6.4 55 Mn 9.8 120 Sn 5.1 56 Fe 9.3 186 W 21.5 64 Ni 5.8 208 Pb 12.2

Laser Ablation Precision Ultimate Precision: 0.02% RSD

Steel substrate NIST 1359B Copper on Brass 45um layer of Cu protective layer of Cr

NIST 1359B Copper on Brass 4-5nm depth resolution per pulse

Where speed & simultaneity really matter High-precision isotope ratios Optimal internal standardization Situations where the signal shape is critical Flow injection Electrothermal vaporization Time-varying signals (e.g. LC, GC, CE) Modulation methods Fast transients (e.g. in situ laser ablation)

Chromatography with ICPADAMS GC, LC, CE being pursued

Lanthanides by LC-ICP-ADAMS