Integral V-Cone Flowmeter VD series

Similar documents
MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

AM-1000 Series COMPACT FLOWMETER

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

V-Cone Flowmeter DATASHEET

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Target Insertion Flowmeter

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

MCE380: Measurements and Instrumentation Lab

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Volumetric Flow Measurement

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Electromagnetic Flowmeter

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

ED 701 General Industry Pressure Transmitter

VORTEX FLOWMETER (DELTA FLOWPET)

CHAPTER (13) FLOW MEASUREMENTS

Laboratory work No 2: Calibration of Orifice Flow Meter

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Field IT 50T Series Transmitters

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

SST Tag: Message: (32 characters)

LDE/LME/LMI pressure sensors in bypass configuration for gas flowmeters

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Experiment No.4: Flow through Venturi meter. Background and Theory

Flow Measurement in Pipes and Ducts COURSE CONTENT

Model Selection 1. Process Valves

473-SHX Dew Point Mirror

Model Selection 1. Process Valves. Air. Vacuum

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

close to performances of the turbine gas meters designed for custody transfer measurements.

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

FLOW MEASUREMENT IN PIPES EXPERIMENT

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

14:1400 (0206) KRAL Volumeter - OMG

Product Discontinued

MODEL : TX Series (Nom. sizes 15mm to 400mm)

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

AM7000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Pressure Transmitter ED 701

Cooling Water Flow Regulator

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

The 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

473 Dew Point Hygrometer

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

2/3 Port Valves for Fluid Control Model Selection 1

ALASTAIR MCLACHLAN Applications Cameron

2/3 Port Valves for Fluid Control Model Selection 1

473 Dew Point Hygrometer

Instrumentation & Data Acquisition Systems

VA Master FAM540 Metal Cone Variable Area Flowmeter

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

Lecture23. Flowmeter Design.

Tecnología en Electrónica y Control SRL Ficha Técnica

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

SVH with HYDROVAR (HVL range)

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

Operating Instructions for Digital Manometer. Model: MAN-SD

Installation guide 862 MIT / MIR

5 ENERGY EQUATION OF FLUID MOTION

Industrial Resistance Thermometers according to DIN Model MWD

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

FXP DATASHEET JUNHO 2013

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Transcription:

TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing Orifice system, all necessary components for measuring flow rate of various fluids are combined and assembled for immediate start-up just by installing onto process piping and connecting with 2 core wiring. Connection and installation of bypass piping, 3 way valve and transmitter is not necessary. FEATURES Wide application V-Cone can measure almost all process fluids, i. e., liquids, slurries, gases and steam. Short straight runs By the unique flow restriction theory, the required straight runs both for upstream and downstream are much shorter than those for traditional orifice plates. Effective for space and cost saving for plant construction. Wide range ability V-Cone sensor offers 14:1 range ability which is much wider than orifice and Vortex flowmeters. Low permanent pressure loss The signal stability of V-Cone is more stable than that of orifice plates. Thus, the required P and per manent pressure loss are also much lower than orifice system. This saves total energy consumption in plants. Durable against wear and sticking V-Cone has "Self-Cleaning" capability because the fluid runs off from the beta edge of the Cone. Size availability 15mm (1/2") to mm (12") are ready to select to cover almost all possible line sizes. Easy installation and handling Bypass piping has been already done which saves installation and maintenance costs dramatically. RECOMMENDED APPLICATIONS Steam lines Various gas lines Burning gas lines Water and other liquids Slurries Others STANDARD SPECIFICATION Available size : 15mm (1/2") to mm (12") Process connection : Flange connection JIS10KRF or ANSI# Other flanges on request Material V-Cone Sensor : 304SS Piping : 304SS 3 way valve : 316SS Transmitter fluid contact : 316SS Seal : TEFLON and Viton Measuring Fluid : Steam, Liquids or Gases Temp. and Press. Range Type of fluid Steam Liquids Gases Fluld temp. General purpose ~190 40~120 40~120 C Press. tight Ex-proof ~190 20~120 20~120 Fluid Press, kgf/cm 2 G MPa AMB Temp. General purpose Press. tight Ex-proof Storage Temp. Flow direction ~10 ~0.98 : 40~90 C : 20~80 C : 20~60 C Range ability : Standard 14:1 Accuracy Liquid Steam and Gases Required straight runs Process piping condition Single plane elbow at up and/or down stream Reducer at up stream Other fittings or valves at up and/or down stream D : Nominal diameter of V-Cone sensor ~14 ~1.37 0.5~9.9 0.05~0.97 : Horizontal (Left to right or Right to left) : ±1.0%F.S. : ±1.5%F.S. Up stream Min. 0D Min. 2D Down stream Min. 3D Min. 5D TG-F822-1E Jun., 3

Power supply : General purpose and Press. tight Ex-proof : DC10.5~45V Output : DC4~20mA, Linear for flow rate of 0~% Max. Load : 600 at DC24V supply Flow rate indication : By 5 dight LCD digital indication Standard Option Flow rate in industrial unit Differential pressure in kpa unit 0~% Housing Ex-proof : JISC9020 class water tight (Equ. to IP67) Ex-d version EP-VD- JIS EXdo IIB + H2T4 Cable entry : 2 G1/2 : Supplied pressure tight cable glands (For 11mm dia cable) are to be used for Ex-d version. Terminal : M4 screw Painting of transmitter : Silver and Blue Installation Standard : By direct installation onto process piping through flanges. Special support is provided small sized versions. Refer to DIMENSION for details. MODEL CODE NOTE CONSTRUCTION COMBINATION *1 FLUID CONNECTION FLOW DIRECTION SIZE BETA RATIO *2 EP VD VD VD 1 2 3 4 1 2 3 1 2 9 6 7 01 02 03 04 05 06 08 10 13 15 20 25 30 85 75 65 55 45 GENERAL PURPOSE PRESSURE TIGHT EX-PROOF SENSOR+TRANSMITTER SENSOR+TRANSMITTER (DEGREASE TREATMENT) SENSOR+3WAY VALVE+TRANSMITTER SENSOR+3WAY VALVE+TRANSMITTER (DEGREASE TREATMENT) STEAM LIQUID GAS JIS10KRF FLANGE ANSI#FLANGE OTHER SPECIAL LEFT TO RIGHT (HORIZONTAL) RIGHT TO LEFT (HORIZONTAL) 15mm 20mm 25mm 40mm 50mm 65mm 80mm mm 125mm mm mm mm mm β=0.85 β=0.75 β=0.65 β=0.55 β=0.45 *1 : 3 way valve is required for removal of transmitter under operation and also for zero adjustment during operation. *2 : Beta ratio will be decided according to specification at factory. 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 5" 6" 8" 10" 12" 2 TOKYO KEISO CO., LTD. TG-F822-1E

MEASURING PRINCIPLE The V-Cone is a differential pressure type flowmeter. Theories behind differential pressure type flowmeters have existed for over a century. The principal theory among these is Bernoulli's theorem for the conservation of energy in a closed pipe. This says that for a constant flow, the pressure in a pipe is inversely proportional to the square of the velocity in the pipe. Simply, the pressure decreases as the velocity increases. For instance, as the fluid approaches the V-Cone meter, it will have a pressure of P1. As the fluid velocity increases at the constricted area of the V-Cone, the pressure drops to P2, as shown here. Where Q = flowrate in actual cubic feet per second. k = constant that can change according to a particular flowmeter, dimensionless (see below for the equation for k for the V-Cone). Y = gas expansion factor, dimensionless.(y=1 for noncompressible applications) P = differential pressure in pounds per square foot. ρ = fluid density in pounds per cubic foot. Both P1 and P2 are measured at the V-Cone's taps and the difference is P : For the V-Cone : P = P1 P2 The P created b y V-Cone will increase and decrease exponentially with the flow velocity. As the constriction takes up more of the pipe cross-sectional area, more differential pressure will be created at the same flowrates. The ratio between the open pipe area and the open area at the largest cross-section of the cone is the Beta ratio. The equation for the Beta ratio of a V-Cone is : where D 2 d 2 D β = Beta ratio D = inside diameter of the pipe. d = outside diameter of the cone. If Q represents the flowrate, the equation of flow for a differential pressure type flowmeter is : Q ky P ρ k= π Cd 4 2Gc D2 2 1 4 where k = V-Cone meter constant, dimensionless. Gc = gravitational constant in feet per second squared. D = inside diameter of the pipe in feet. β = Beta ratio of the V-Cone, dimensionless. Cd = calibrated coefficient of discharge, dimensionless. Mass V-Cone flowmeter In measuring the saturated steam, we recommend to use VM deries with density compensation function built in. PTIONAL UNITS Panel instruments a. IR-6000 DIN48 48, Indication. Totlization, High and low alarm, DC24V Power supply b. IR-4 DIN96 48, Indication. Totalization (Alternative), High and low alarm, DC24V Power supply c. IR-3 Indication, high and low alarm d. IR-3400 Indication only TG-F822-1E TOKYO KEISO CO., LTD. 3

4 TOKYO KEISO CO., LTD. TG-F822-1E POSSIBLE MEASURING RANGE SIZE STEAM PRESS. (TEMP.) 1kgf/cm 2 0.1 MPa (120 C) 2kgf/cm 2 0.2 MPa (134 C) 3kgf/cm 2 0.3 MPa (144 C) 4kgf/cm 2 0.4 MPa (152 C) 5kgf/cm 2 0.5 MPa (159 C) 6kgf/cm 2 0.6 MPa (165 C) 7kgf/cm 2 0.7 MPa (171 C) 8kgf/cm 2 0.8 MPa (175 C) 9kgf/cm 2 0.9 MPa (180 C) 10kgf/cm 2 1.0 MPa (184 C) 15mm 20mm 30mm 40mm 50mm 65mm 80mm mm 125mm mm mm mm mm 26.8 35 62.5 46.3 60 108 74.3 95 175 121 428 197 702 278 996 426 1530 740 2670 1140 0 4040 1690 5980 2840 5 9960 4470 8 15 6420 20 32.6 45 92.3 37.7 80 160 60.4 257 147 631 239 1030 338 700 1470 519 2260 901 0 3920 1380 5970 2050 4 8 3450 7 14700 5440 22900 7810 0 30 37.4 55 117 43.3 203 69.4 327 169 803 275 600 1320 388 850 1870 596 2880 1040 0 4990 1590 3 7570 2 5 11 3960 9000 18700 6 0 29 8970 00 41 26.3 65 146 45.5 253 72.9 408 178 450 289 1640 408 2330 626 3580 1 6220 1670 4 9480 2470 7000 14000 4160 23 6570 0 36 9420 00 5 26.9 75 176 46.5 305 74.5 491 181 550 1210 295 950 1980 417 2 639 0 4320 1120 3 7 1700 5 11 2520 0 16 4 0 20 6710 00 43700 9630 0 60 27.9 90 48.2 347 77.3 559 188 650 1370 306 2 432 3190 663 0 4920 1190 4000 8540 1760 6000 12900 2620 9 19 4410 0 31900 6960 00 49 9990 30 70600 28.6 224 49.4 389 79.2 627 193 70 1540 313 2520 442 0 3580 678 0 5510 1190 4 9570 1810 7000 14400 2670 2 4520 0 35 7130 00 55 10 79 30.2 252 52.2 437 83.7 704 204 850 1730 332 2830 468 0 4020 719 6190 1260 0 10700 1890 0 16 2840 24 4780 00 40 7540 0 62600 10900 40 88900 30.4 283 50.2 490 80.5 400 790 196 950 1940 319 3180 450 0 4510 691 3 6940 1210 6000 12 1840 9000 18 2730 0 27000 4590 00 45 7 30 70 10 00 99700 30.3 311 52.4 540 84.1 450 870 204 2130 332 3 470 0 4970 722 3 7650 1 6 13 1900 20 2840 0 29 4 00 49700 7580 77400 10900 50 1 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 5" 6" 8" 10" 12" Table 1 : For Saturated Steam Flow Measurement Flow unit (kg/h)

Table 2 : For Air Flow Measurement Flow unit (Nm 3 /h) PRESS. ATM. 1kgf/cm 2 0.1 MPa 2kgf/cm 2 0.2 MPa 3kgf/cm 2 0.3 MPa 4kgf/cm 2 0.4 MPa 5kgf/cm 2 0.5 MPa 6kgf/cm 2 0.6 MPa 7kgf/cm 2 0.7 MPa 8kgf/cm 2 0.8 MPa 9kgf/cm 2 0.9 MPa 10kgf/cm 2 1.0 MPa 15mm 1/2" (25.5) (30) (36.7) 33.3 35 72.6 28.8 40 103 33.3 60 144 37.3 70 181 27.3 80 198 29.5 248 31.6 266 33.5 314 35.3 3450 37.1 381 20mm 3/4" (31.7) (40) (63.6) 40.6 60 125 49.9 75 179 57.5 43.1 314 47.2 345 51.1 430 54.6 461 57.9 545 61.1 599 64.1 661 30mm 1" (51.0) (70) (102) 65.2 90 202 80.0 288 61.7 404 69.1 505 75.7 556 81.8 692 87.5 743 92.9 400 878 98.0 450 965 104 1060 40mm 1 1/2" (87.2) () (251) 159 497 130 706 151 400 992 168 1240 184 650 1360 199 850 1700 213 900 1820 226 2 238 2370 2610 50mm 2" (142) () (412) 260 816 212 1160 245 1620 271 2030 2230 324 2780 347 2990 368 3530 388 0 3880 407 0 4280 SIZE 65mm 80mm 2 1/2" 3" (202) () (585) (311) (450) (900) 244 1 374 1770 299 1640 459 2530 346 2 530 3550 387 2880 593 0 4440 424 3170 650 0 4890 458 0 3950 703 6080 490 0 4240 751 6530 520 0 5010 797 3 7710 548 0 5 841 4000 8480 575 6070 882 4 9 mm 4" (357) (750) (1560) 649 3090 796 0 4390 920 6160 1040 4000 7710 1140 4 8490 1230 0 10 1310 5 11 1390 6000 13400 1470 7000 14700 1540 0 16 125mm 5" (544) () (2370) 987 0 4700 1220 6660 1410 4 9370 1580 5 11600 1730 6 12 1870 0 15900 0 8 17 2120 20 2230 23 2340 24600 mm 6" (809) () (3510) 1480 6940 1810 0 9850 2090 6 13 2340 8 17 2570 9 19000 2770 23700 2970 25400 3450 0 0 3320 0 3 3480 0 36400 mm 8" (1360) () (5850) 2490 5 1 3050 0 16400 3530 2 3950 0 28 4320 0 31700 4670 00 39 0 00 42400 00 50 5590 00 55 5870 0 60700 mm 10" (2) (4) (9110) 3920 8 10 4810 25600 5560 0 36000 6220 00 44900 6820 00 49 7370 0 6 7880 0 66 8370 78 8820 85 9260 40 94600 mm 12" (3090) (6) (12900) 5630 25 6700 0 36 7980 00 5 8930 0 63 9790 30 70 10700 87 11400 40 93 12 50 11 12 60000 120 13400 60 134000 NB : Accuracy guaranteed range ability will be 10:1 for the flow rate indicated in brackets ( ). TG-F822-1E TOKYO KEISO CO., LTD. 5

Table 3 SIZE : Full Span for Water Flow Measurement (15 C, 0.5kg/cm 2 G) 15mm 20mm 25mm 40mm 50mm 65mm 80mm mm 125mm mm mm mm mm 1/2" 1/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 5" 6" 8" 10" 12" 2.2 2.5 5.6 3.8 4.0 9.7 4.8 5.0 15.5 12 15 38 20 25 62 28 40 89 43 60 136 74 103 237 113 361 168 533 283 890 446 600 1380 639 1960 Flow unit(m 3 /h) REMARKS Table 1~3 indicate maximum flow rate with guaranteed accuracy under specified size and pressure. Upper line : Minimum Possible Span Middle line : Standard Span Lower line : Maximum Possible Span Accuracy guaranteed range ability is 14:1 of full scale Span (10:1 in some occasion) Sizing, Differential pressure and pressure loss calculation with specified condition is available on request. Refer to ORDERING IN- FORMATION and contact Tokyo Keiso. DIMENSIONS Fig. a For STEAM and LIQUIDS Size 15~40mm (1/2~1-1/2" ) Flow direction:left to Right or Right to Left Fig. b For GASES Size 15~40mm (1/2~1-1/2" ) Flow direction:left to Right Fig. c For STEAM and LIQUIDS Size 50mm and above (2" and above) Flow direction:left to Right 6 TOKYO KEISO CO., LTD. TG-F822-1E

Fig. d For STEAM and LIQUIDS Size 50mm and above (2" and above) Flow direction:right to Left Fig. e For GASES Size 50mm and above (2" and above) Flow direction:left to Right Fig. f For GASES Size 50mm and above (2" and above) Flow direction:right to Left Size (mm) (" ) 15 20 25 40 50 65 80 125 1/2 3/4 1 1 1/2 2 2 1/2 3 4 5 6 8 10 12 L (mm) 203 203 203 254 305 305 356 406 559 559 660 711 762 B (mm) 116 116 116 129 135 135 154 154 160 W (mm) 44 47 50 57 132 138 146 174 187 201 241 268 294 REMARKS 1) Fig.a~f indicate dimension for "With 3way valve" versions. 2) Pressure tight cable glands are provided for pressure tight ex-proof versions. H (mm) With 3 way valve Without 3 way valve STEAM LIQUID GASES STEAM LIQUID GASES 336 344 351 376 391 401 436 461 486 381 389 396 421 436 446 481 506 531 246 254 261 286 301 311 346 371 396 291 299 306 331 346 356 391 416 441 Fig. a.b a.b a.b a.b TG-F822-1E TOKYO KEISO CO., LTD. 7

ORDERING INFORMATION Specify the following for order/inquiry; CUSTOMER CONTACT Model code selection -VD- - Refer to MODEL CODEL and specify. Process condition Tag No. Fluid name Temp. ( ) C ( ) Press. ( ) kg/cm 2 G ( ) kpa (gauge) Viscosity ( ) cp mpa s ( ) Sp. Gr. (Density) ( ) kg/m 3 kg/nm 3 ( ) Humidity (Only for steam) ( ) % Staturated Process flow rate Full scale Nor Max Min ( ) m 3 /h Nm 3 /h kg/h ( ) Other instructions General purpose Low pressure loss required (Allowable pressure loss kpa) Other special instruction, if any * Specification subject to change without notice Head Office : Shiba Toho Building, 1 7 24 Shibakoen, Minato-ku, Tokyo 105 8558 Tel : 03 3431 1625 (KEY) ; Fax : 03 3433 4922 e-mail : overseas.sales@tokyokeiso.co.jp ; URL : http://www.tokyokeiso.co.jp 8 TG-F822-1E