LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Similar documents
PO Beam Waist Size and Location on the ISC Table

Heating Beam Pattern Optical Design CO2 Laser Thermal Compensation Bench

ISC In-vacuum Gouy phase telescopes

Beam Splitter Optical Surface Deformation due to Gravity

Any first year text, sections on atomic structure, spectral lines and spectrometers

Core Optics Support Conceptual Design

Galileo Telescope Solar Viewer Joseph Hora, Elizabeth Hora 2017/09/18

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

LIGO I mirror scattering loss by non smooth surface structure

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Spatial Dependence of Force in the Initial LIGO OSEMs

LIGO Laboratory / LIGO Scientific Collaboration LIGO. aligo BSC-ISI, Pre-integration Testing report, Phase II (before cartridge install) E V6

Case Study: Faraday Rotators in LIGO

THE DIFFRACTION GRATING SPECTROMETER

Experiment O-2. The Michelson Interferometer

5 TH ERMAL GRADIENT INTERFEROMETRIC MEASUREMENT

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

MELOS 530 MEASURING EQUIPMENT FOR LENSES AND OPTICAL SYSTEMS. Combinations and Accessories. Indispensable for Quality Control of Optics

Core Optics Support Design Requirements Document

Gravitational Waves & Precision Measurements

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

Drag Wiping with Methanol vs First Contact

LAB 10: OPTICAL MATERIALS AND DISPERSION I

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

Tutorials. 1. Autocollimator. Angle Dekkor. General

OPERATIONS SUPPLEMENT FOR THE COMPARISON AUTOCOLLIMATOR, D600

Validation of the Source-Detector Simulation Formulation

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

GP-B Telescope Determine Metering Tube Length P0364 Rev -

Implementing an Alignment Sensing and Control (ASC) System for the 40m Prototype Interferometer

Non-Linear Response of Test Mass to External Forces and Arbitrary Motion of Suspension Point

EUV Reflectivity measurements on Acktar Sample Magic Black

x Builders Level Service Manual

Experiment #4: Optical Spectrometer and the Prism Deviation

One-Year Limited Warranty

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

Atomic and nuclear physics

PHY410 Optics Exam #3

Status of the LIGO Project

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

[ Extract from Astronomical Spectroscopy for Amateurs ] 18.0 Guiding, OAG and Beam splitters/ Flip mirrors Off Axis Guiders

DISPERSION OF A GLASS PRISM

Daily Alignment Procedure with 2 AO Wave Front Sensors

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

Observing Procedure for C11 GPS

Visible Spectrometer

GERMAN TYPE EQUATORIAL MOUNT (FM 51/52 - FM 100/102 - FM150) USER MANUAL

Miniball Flexible Frame

C A S S I N I TRACKER

EXPERIMENTAL INVESTIGATION OF PRECESSION AND NUTATION OF A GYROSCOPE AND DETERMINATION OF MOMENT OF INERTIA

Installation and testing of L1 PSL table legs

Lab 2: Mach Zender Interferometer Overview

Newtonian 17.5-inch Optical Tube Assembly

Optics Optical Testing and Testing Instrumentation Lab

Instruction Manual. Omegon EQ-500 Equatorial Mount English version Rev A

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

Dispersion of light by a prism

Leveling. 3.1 Definitions

Use of computer generated holograms for alignment of complex null correctors

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Laboratory #29: Spectrometer

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

The IPIE Adaptive Optical System Application For LEO Observations

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Auto collimator. Introduction. Objectives: Apparatus: Theory:

Visible Spectrometer

EE Camera & Image Formation

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

LIGO On-line Documents July 1997

Polar Alignment of LX200R and Ultra Wedge For The Southern Hemisphere by Chris James

ZFK 4 X 25. Description and Utilization Instructions

SpecterOS4x Optical Sight Operation Manual

First Results from the Mesa Beam Profile Cavity Prototype

RIGHT-ANGLE POLAR ALIGNMENT SCOPE (RAPAS) INSTRUCTIONS

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

2. OPERATIONAL CONDITIONS

THE LOSMANDY G-11 MOUNT

IMPROVING BEAM QUALITY NEW TELESCOPE ALIGNMENT PROCEDURE

Spotting Scope Instruction Manual

Copyright 2010 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only.

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module 5 Lecture 1

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

Experiment #5: Cauchy s Formula

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

Automatic Level NP-732

Experiment 8 Michelson Interferometer

Development of a cryogenic compact interferometric displacement sensor

Characterization, Commissioning and Implementation of the Optical Lever System at Caltech s 40m Advanced LIGO Prototype Lab

ANALYSIS OF BURST SIGNALS IN LIGO DATA. Irena Zivkovic, Alan Weinstein

Experiment 2: The Speed of Light

Fine Alignment of the ATF Damping Ring

GEO 600: Advanced Techniques in Operation

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

Transcription:

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY Document Type LIGO-T990088-01- D 10/14/99 COS IFO Alignment Procedure Michael Smith Distribution of this draft: xyz Table of Contents Index California Institute of Technology LIGO Project - MS 51-33 Pasadena CA 91125 Phone (626) 395-2129 Fax (626) 304-9834 E-mail: info@ligo.caltech.edu This is an internal working note of the LIGO Project. WWW: http://www.ligo.caltech.edu/ Massachusetts Institute of Technology LIGO Project - MS 20B-145 Cambridge, MA 01239 Phone (617) 253-4824 Fax (617) 253-7014 E-mail: info@ligo.mit.edu LIGO-DRAFT file /home/smith/cos/installation/cos 2K IFO ALIGNMENT.fm - printed Thursday, October 28, 1999

1 2K IFO ALIGNMENT 1.1. 2K FMx Alignment Gate valve #3 will be closed and GV4 will be open during this procedure. 1.1.1. FMx Alignment Apparatus A schematic of the IR autocollimator set up for alignment of the 2K FMx is shown in figure 1. The COS IR autocollimator no. 1 will be mounted on the IAS tripod using a bayonet mount and height adapter with a two-axis tilt mount. The tripod will be located, using LIGO surveying procedures, on the 2K IFO centerline in the removed spool piece WA-1A location on the x-arm of the IFO. An optical reference flat will be placed inside the manifold on the IFO beam axis, and aligned perpendicular to the IFO beam axis using LIGO surveying procedures. A 940 nm diode laser source will be used to illuminate the reticle of the autocollimator. The retroreflected beam from the reference flat will be viewed through the autocollimator eyepiece by means of a 75mm zoom video camera lens imaging onto a SBIC CCD camera. An alignment target, with a hole and a cross marking the 2K IFO optical centerline, will be placed on HAM 9 in front of the RM, and the reticle projected from IR autocollimator no. 1 onto the target will be viewed with an IR video camera mounted on a tripod in the spoolpiece between HAM9 and BSC4. 1.1.2. Calibration of Autocollimator 1.1.2.1 Pointing angle calibration of autocollimator no. 1 The pointing angle of the COS autocollimator will be established by retroreflecting from a surveyed, pre-aligned reference flat placed on the IFO beam axis inside the manifold near the WA- 1A spool piece location, and by tilting the autocollimator to center the image of the retro-reflected reticle pattern on the internal cross hair of the autocollimator. 1.1.2.2 Autocollimator Infinity Focus calibration A corner cube retroreflector will be placed in front of the autocollimator. The camera focus is set at infinity, and the focus of the eyepiece will be adjusted until the camera image of the cross-hair pattern is as sharp as possible. Finally, the infinity focus of the autocollimator is established by adjusting the autcollimator focus knob until the camera image of the retro-reflected reticle is as sharp as possible. 1.1.3. 2K FMx Alignment Procedure After the pointing angle of the autocollimator is established, the reference flat will be removed, and the autocollimator beam will transmit through ITMx, reflect from FMx, and project an image of the reticle on the alignment target located in front of the RM. 2

AUTOCOLL. #1 WA1-A spool piece alignment target HAM9 removable, pre-aligned, reference flat ITMy FMy BSC8 GATEVALVE GV3 BSC4 GATEVALVE GV4 FMx BSC7 HAM10 RM ITMx video camera BS Figure 1: COS Alignment of 2K FMx 3

1.1.3.1 Alignment Target on HAM9 An alignment target to mark the IFO beam centerline will be placed on HAM9 directly in front of the RM, as shown in figures 5 and 6. The height of the target is referenced to the known height of the optical table. The lateral position of the target is referenced to the center of the optical table, with corrections to account for the actual position of the RM centerline. The focus control of the autocollimator no. 1 will be adjusted until the projected reticle pattern on the target is as sharp as possible. 1.1.3.2 FMx Tilt Adjustment The aximuth and elevation tilt angles of the 2K FMx will then be adjusted until the projected reticle is aligned with the cross on the alignment target. 1.2. 2K APS Telescope Alignment After the FMx has been aligned, the APS telescope will be positioned on HAM 10 and aligned to the transmitted beam from autocollimator no. 1 through the beam splitter, as shown in figure 2. COS autocollimator no. 2 will be placed into the holder at the output of the APS telescope for the final alignment of the APS telescope, as shown in figure 3. The internal alignment target will be installed near the primary mirror. The APS telescope gimbal mount will be translated horizontally and vertically to center the cross on the target with the projected reticle pattern from autocollimator no. 1. When this is completed, the rear gimbal mount of the APS telescope will be firmly clamped to the HAM 10 optical table. The internal alignment target will be moved to the entrance of the telescope, and the front telescope mount will be translated horizontally and vertically to coarsely center the cross on the target with the projected reticle pattern from autocollimator no. 1. Finally, the front target will be removed and the input end of the APS telescope will be finely tilted in elevation and azimuth until the internal cross-hair of autocollimator no. 2, at the output of the APS telescope, is aligned with the projected reticle pattern from autocollimator no. 1. When this procedure is accomplished, the front mount of the APS telescope will be locked and firmly clamped to the HAM 10 optical table. 4

AUTOCOLL. #1 WA1-A spool piece ITMy FMy BSC8 AUTOCOLL. #2 APS TELESCOPE BS GATEVALVE GV3 BSC4 GATEVALVE GV4 FMx BSC7 HAM10 ITMx RM HAM9 Figure 2: COS Alignment of 2K APS Telescope 5

LIGO-T990088-01-D autocollimator #2 alignment target input end gimbal mount front mount Figure 3: 2K APS Telescope Alignment 1.3. 2K RM ALlGNMENT 1.3.1. Autocollimator Behind the RM Autocollimator no. 2 will be mounted in a two-axis tilt holder on a two-stage Velmex slide mechanism and positioned on the 2K IFO centerline behind the RM on HAM 9, as shown in figures 4, 5, and 6. The hole in the alignment target allows the central portion of the projected reticle pattern from the reference beam of autocollimator no. 1 to transmit through the RM and be received by autocollimator no. 2. 1.3.1.1 Pointing Angle Alignment The pointing angle of autocollimator no. 2 will be aligned by adjusting the elevation and azimuth tilt angles of autocollimator no. 2 until the internal cross-hair is aligned with the received reticle pattern from the projected reference beam. 1.3.1.2 Centering Alignment The centering of autocollimator no. 2 with the reference beam will be accomplished by translating autocollimator no. 2 horizontally and vertically, using the Velmex slide mechanism, until a target placed at the center of the input aperture of autocollimator no. 2 is aligned with the projected reference reticle pattern. 6

AUTOCOLL. #1 WA1-A spool piece alignment target AUTOCOLL. #2 HAM9 removable, pre-aligned, reference flat ITMy FMy BSC8 GATEVALVE GV3 BSC4 GATEVALVE GV4 FMx BSC7 HAM10 RM ITMx video camera BS Figure 4: Alignment of RM 7

target autocollimator #2 RM Figure 5: Alignment Target and Autocollimator on HAM9, Elevation View 8

RM autocollimator #2 target Figure 6: Alignment Target and Autocollimator on HAM9, Plan View 1.3.1.3 Alignment Iteration The pointing angle of autocollimator no. 2 will be finalized by repeating the pointing angle alignment step described above. 1.3.2. 2K RM Alignment Now the angular alignment of the RM can be checked by turning on the 940 nm illumination source of autocollimator no. 2 and retroreflecting from the HR side of the RM. And the elevation and azimuth tilt angles of the RM can be adjusted to agree with the pointing angle of autocollimator no. 2. 1.4. 2K FMy Alignment Gate valve #4 will be closed and GV3 will be open during this procedure. The 2K FMy mirror will be aligned by projecting a reference beam from the autocollimator behind the RM, passing through the BS, reflecting from the FMy, reflecting from the ITMy, and 9

returning to the BS and reflecting toward the aligned APS telescope on HAM10, as shown in figure 7. Autocollimator no. 1 will be placed at the output end of the APS telescope. The elevation and azimuth tilt angles of FMy will be aligned until the projected reference reticle pattern is centered on the internal cross-hair of the autocollimator at the output of the APS telescope. 1.5. APS Steering Mirrors Alignment Autocollimator no. 2 will be placed at the input end of the APS telescope, as shown in figure 8. Projecting from autocollimator no. 2 with a 990 nm diode laser illumination source and viewing with a camera through autocollimator no. 1, the autocollimator no. 2 will be pointed in elevation and azimuth until the projected reticle is aligned with the internal cross-hair of autocollimator no. 1, at the output of the APS telescope. Autocollimator no. 1 will now be removed from the output of the APS telescope. The projected reticle pattern from autocollimator no. 2 will be progressively focussed on each steering mirror, shown in figure 9, and the steering mirror will be centered on the reticle pattern and pointed toward the next mirror to define the desired beam path on the HAM10 optical table. The last steering mirror will be pointed to project the output reticle pattern onto a surveyed target which marks the center of the APS output window of HAM10. 10

AUTOCOLL. #1 APS TELESCOPE HAM10 11 Figure 7: COS Alignment of 2K FMy ITMy FMy BSC8 BS GATEVALVE GV3 BSC4 GATEVALVE GV4 video camera RM HAM9 alignment target AUTOCOLL. #2 LIGO-T990088-01-D ITMx FMx BSC7

LIGO-T990088-01-D autocollimator #1 alignment target input end autocollimator #2 gimbal mount front mount Figure 8: 2K APS Telescope Steering Mirror Alignment Beam 12

HAM_10 21.5 H10_3 H10_2 H10_1 H10_4 98.9 81.0 111.3.80" H10_5 109.1 H10_6 HAM_10 Table Mirrors Figure 9: PO Telescopes 2K ITMy, 2K BS, 2K APS orientation 13

1.6. 2K ETM Telescope Alignment 1.6.1. 2K ETM Telescope Alignment Apparatus A schematic of the IR autocollimator set up for alignment of the ETM telescope is shown in figure 10. The COS IR autocollimator will be mounted on the IAS tripod using a bayonet mount and height adapter with a two-axis tilt mount. The tripod will be located, using LIGO surveying procedures, on the 2K IFO centerline in the removed spool piece located adjacent to the gate valve GV10 at the y-midstation of the IFO. A 940 nm diode laser source will be used to illuminate the reticle of the autocollimator. The retroreflected beam from the ETM mirror will be viewed through the autocollimator eyepiece by means of a 75mm zoom video camera lens imaging onto a SBIC CCD camera. An alignment target, with a hole and a cross, will be placed at the entrance to the ETM telescope on the optical centerline, and the reticle projected from the IR autocollimator onto the target will be viewed with an IR video camera mounted on a tripod inside the BSC6 chamber. 1.6.2. Calibration of Autocollimator 1.6.2.1 Pointing angle calibration of autocollimator no. 1 The pointing angle of autocollimator no. 1 will be established by retroreflecting from the HR surface of the ETM mirror, and by tilting the autocollimator to center the image of the retro-reflected reticle pattern on the internal cross hair of the autocollimator. 1.6.2.2 Autocollimator Infinity Focus calibration A corner cube retroreflector will be placed in front of the autocollimator. The camera focus is set at infinity, and the focus of the eyepiece will be adjusted until the camera image of the cross-hair pattern is as sharp as possible. Finally, the infinity focus of the autocollimator is established by adjusting the autcollimator focus knob until the camera image of the retro-reflected reticle is as sharp as possible. 1.6.2.3 Projected Reticle Pattern The projected reticle pattern will be focussed onto the surface of the alignment target at the entrance to the ETM telescope by means of the focus knob on the autocollimator. 1.6.3. 2K ETM Telescope Alignment Procedure 1.6.3.1 Alignment of Entrance Aperture of ETM Telescope The lateral position and azimuthal orientation of the entrance aperture of the telescope will be coarsely adjusted by positioning the telescope mounting post on the BSC optics table and clamping to the table with the hold down clamps. The elevation of the telescope will be coarsely adjusted by means of the slotted vertical mounting base. 14

ETM telescope steering mirror BSC6 input target ETM mirror video camera video camera output window output target video camera autocollimator #1 Figure 10: Alignment Apparatus for the ETM Telescope 15

The fine adjustment of the lateral position, azimuth, and elevation of the entrance aperture of the telescope will be adjusted by means of the fine adjustment screws until the cross of the target at the input of the telescope is aligned with the projected reticle pattern from the autocollimator. 1.6.3.2 Tilt Alignment of ETM Telescope The steering mirror at the output end of the telescope will be removed. Autocollimator no. 2 will be inserted into the alignment bore at the output end. Autocollimator no. 1 will be set to infinity focus. The telescope will be tilted in azimuth and elevation by means of the fine adjustment screws on the output side of the telescope mounting structure until the internal cross hair of autocollimator no. 2 is centered with the projected reticle pattern from autocollimator no. 1. 1.6.4. Alignment of ETM Telescope Steering Mirror Autocollimator no. 2 will be removed from the back of the ETM telescope, and the steering mirror will be installed. The steering mirror will be coarsely rotated within its mounting base, and finely tilted by means of the x-y mirror adjustment screws until the projected reticle pattern is centered on the cross of the translucent alignment target placed against the outside of the output window. The target will be viewed by an IR video camera outside the BSC6 chamber. 1.7. Alignment of ETM PO Beam Dump The projected reticle pattern from autocollimator no 1 will pass through the ETM telescope and be directed to the center of the output window. An IR video will be placed inside BSC6 to observe the ETM PO beam dump. The ETM PO beam dump will be positioned on the BSC6 optical table so that the reflected reticle pattern from the output window will hit the center of the beam dump. 16