Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0)

Size: px
Start display at page:

Download "Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0)"

Transcription

1 Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0) spheretest@aurora.eu.com

2 Customer: Product code: Customer: Product code: Test Date: Product 08/12/2015 description: Integrating Sphere Test Request Tested By Engineer: Test Date: 2

3 (FLIPPED) Measured Lumen (lm) Measured Useful Lumens within 120degrees Max Luminous Intensity (cd) Beam Angle (º) LOR* - Power factor Power (Including Gear, W) Source Description Manufacturer M. Rated Lumens (lm) 3300 M. Rated Watts (W) 40 Colour Temperature (K) 3000 Source Type LED Gear Description Manufacturer Part Number AU-LPDD1 Dimensions Luminaire Dims (mm) Optical Dims (mm) 1195x295x x250 Accessories Description - The luminaire is not treated as symmetric. Ambient temperature 25±1 ºC * - Measured Lumen output value relative to M. Rated Lumen 3

4 Customer: Product code: Customer: Product code: Test Date: Product 08/12/2015 description: Integrating Sphere Test Request Tested By Engineer: Test Date: 4

5 Customer: Product code: Customer: Product code: Test Date: Product 08/12/2015 description: Integrating Sphere Test Request Tested By Engineer: Test Date: 5

6 09/12/2015 6

7 09/12/2015 7

8 (FLIPPED) 09/12/2015 8

9 (FLIPPED) 09/12/2015 9

10 (FLIPPED) 09/12/

11 (FLIPPED) 09/12/

12 09/12/

13 Equipment Information: Goniophotometer:: Radiant Imaging PM-NFMS-0800 & ProMetric CCD Imaging Photometer Illuminance Meter:: KONICA MINOLTA T-10/T-10M Power analyser: EVERFINE PF9811 Uninterruptible Power Supply:: BORRI B B PM-NFMS is a Near-Field Imaging Goniophotometer, which combines a motorised goniometer stage with a ProMetric CCD imaging photometer to perform a near-field angular analysis of the luminance and colour from LEDs, luminaires and solid state lighting. ProSource software then scales this to far-field luminous intensity data from which standard photometric files are generated (IESNA, EULUMDAT). The PM-NFMS employs a ProMetric CCD imaging photometer to record spatially-resolved images of the near-field luminance emitted from the light source. Luminance (units of cd/m 2 ) is the optical property one measures when working up close to the light source. Spatially-resolved images of the source luminance are recorded in Radiant Imaging's proprietary ProSource (.rs8) format for one angle of azimuth and elevation at a time. The associated, motorised goniometer stage scans the device under test over ± 88 in all directions. Radiant Imaging's ProSource software then performs a ray-tracing operation to scale the near-field luminance readings to equivalent far-field illuminance values. Standard photometric files in the IESNA (.ies) and EULUMDAT (.ltd) format can then be generated. Specification: Approx. Max. Linear Luminaire Length (mm) 1600 Max. Luminaire Weight (kg) 25 Recommended Max. Luminaire Size (mm) 865 x x Max. Luminaire Size for Recessed Fittings 700 x 355 Operating Range, Azimuth ± 90 Operating Range, Elevation ± 90 + The PM-NFMS0800 can be used to measure a 600 x 600 2D luminaire, mounted off-axis. 1 3

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight Page 2 of 14 Report No.: 68.184.15.296.01 Test sample... : Type of test object... : LED Downlight LED Downlight Trade mark... : Model and/or type reference... : EF150-26W-840 Rating(s)... : 220-240V~;

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB15W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,

More information

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd. NVLAP LAB CODE:201045-0 TEST REPORT IES LM-79-08 For Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Report

More information

Standard-Tech Co. Ltd Testing Center

Standard-Tech Co. Ltd Testing Center Test Datasheet Test Location: [ ] 1. B802, No.11 Caipin Road, Guangzhou Science City, Guangzhou, [ ] Guangdong, China 2. R108, 1 st Floor No.69 GuangPu West Road, Guangzhou Science City, Guangzhou, Guangdong,

More information

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS 71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/827K-DIM-G6 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous

More information

TEST REPORT : Report Reference No... : V2.0. Tested by (name + signature)... : Fair Deng.

TEST REPORT : Report Reference No... : V2.0. Tested by (name + signature)... : Fair Deng. TEST REPORT Report Reference No.... : 4323305.50 V2.0 Tested by (name + signature)... : Fair Deng. Approved by (name + signature)... : Jason Zhang.. Date of issue... Number of pages. Testing Laboratory...

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For Shenzhen Jiawei Photovoltaic Lighting Co., Ltd. No. 1,2,3,4, Xinfa Industry Zone, Central Community, Pingdi Road, Longgang District, Shenzhen City, Guangdong

More information

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL IES LM-79-08 MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Test Model: IGTFL-1515050 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM IES LM-79-08 MEASUREMENT AND TEST REPORT For Eiko Limited 23220 W. 84th Street,Shawnee, KS, USA Test Model: LEDP-13WPAR30/NFL/830-DIM Report Type: Test Engineer: Electrical and Photometric tests including:

More information

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim Report No: L121706467 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706467 Issue Date: 1/16/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Lighting Sciences

Lighting Sciences Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT BEAM SIDE LUMENS

More information

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For IES LM-79-08 MEASUREMENT AND TEST REPORT For MESTER LED LIMITED 3rd F, Building A,Sunshine Industrial Park, Hezhou, Xixiang, Bao an District,Shenzhen China Test Model: PL09G2427KBQH Report Type: Electrical

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15538 Performance Summary Luminous flux Luminaire Power 11541 lm 145.4 W PREPARED FOR : Unilumin Group Co. Ltd., Shenzhen, China. 518103. Page 1 of 1 Performance data in accordance with

More information

Measurement method for the proficiency testing program

Measurement method for the proficiency testing program APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-150W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-100W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000 Report No: L121706547 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706547 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400 Report No: L121706549 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706549 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For IES LM-79-08 MEASUREMENT AND TEST REPORT For Suzhou RUNLUX Electric Ltd. Kunshan Economic&Technological Development Zone, Kunshan City, Jiangsu, P.R.China. Test Model: R1-22TLD30W35K Report Type: Test

More information

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15551 Performance Summary Luminous flux Luminaire Power 2245 lm 27.7 W PREPARED FOR : Unilumin Group Co., Shenzhen, China, 518103. Page 1 of 12 Performance data in accordance with IESNA

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15785 Performance Summary Luminous flux 540 lm Bare Lamp Power 7.76W SHR Nominal 0.75 SHR Maximum 0.79 PREPARED FOR : Indice Ecotech Pty. Ltd., Richmond, VIC 3121. Page 1 of 7 Performance

More information

TEST REPORT For Company:

TEST REPORT For Company: TEST REPORT For Company: EiKO Global, LLC 23220 W. 84th Street, Shawnee, KS 66227 Model: LED17WBR40/840K-DIM-G4 Report Type: Test Engineer: Testing and Report According to ENERGY STAR Program Requirements

More information

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IESLM-79-08TESTREPORT For KINGLUMI CO., LTD Report Number: Product Type: R011601998L1 Track or Mono-point Directional Luminaires Date

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NIST Role in Supporting Solid State Lighting Initiative

NIST Role in Supporting Solid State Lighting Initiative CORM 2007 Annual Meeting, Gaithersburg, May 8-11, 2007 NIST Role in Supporting Solid State Lighting Initiative Yoshi Ohno, Ph.D. Optical Technology Division National Institute of Standards and Technology

More information

Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK

Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK www.42partners.com 42@42partners.com T +44 (0) 1902 453650 F +44 (0) 8721 153400 Registered in England: Company Number 3021552 VAT Registration

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P Test of One Model of LED Track Head Report No.: EED35I000703-2R Prepared for : Progress Lighting Address : 70 Millennium Boulevard Greenville, SC 29607 Model Name : P9082 Model No. : P9082-28, P9082-3,

More information

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P Test of One Model of LED Track Head Report No.: EED35I000702-2 Prepared for : Progress Lighting Address : 70 Millennium Boulevard Greenville, SC 29607 Model Name : P9062 Model No. : P9062-28, P9062-3,

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire TESTING Report No.:BL160912008-9A NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Applicant: Maxlite.Inc Address:

More information

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For Shenzhen sunper opto co., ltd NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For Shenzhen sunper opto co., ltd Report Number: Product Type: R011506618L Architectural Flood and Spot Luminaires

More information

Cat# LED Linear High Bay 100W

Cat# LED Linear High Bay 100W Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

PHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung

PHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested LN130-A30 LED HIGH BAY Prepared for: Janie Chung KMW Inc. 183-6 Youngcheon-ro, Dongtan-myun Hwasung-si, Gyeonggi-do Korea 445-813 Phone: 253-826-7636

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100896445 Date: September 26, 2012 REPORT NO. 100896445CRT-001 TEST OF ONE LED

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA. Report No: L051503301 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503301 Report Prepared For: SPJ Lighting 2107 Chino Ave.

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Test report of IES LM Approved Method: Electrical and Photometric

Test report of IES LM Approved Method: Electrical and Photometric NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Date of issue 2016-05-17 Version 1.0 Total pages 16 Applicant:

More information

LUMINOUS MEASUREMENTS

LUMINOUS MEASUREMENTS Chapter 5. LUMINOUS MEASUREMENTS 5.. Luminous flux (luminous output)............................ 47 5.2. Amount of light (luminous energy)........................... 48 5.3. Luminous intensity.......................................

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320 Report No: L051602710 Date: 5/24/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051602710 HK Lighting Group

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

solid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module

solid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module Light Emitting Diode: p-n solid state module Self - ballasted module Integral module Integral Self - ballasted module Built - in module Built - in Self - ballasted module Independent module Independent

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

AN AUTOMATED GONIOPHOTOMETER FOR LUMINAIRE CHARACTERIZATION

AN AUTOMATED GONIOPHOTOMETER FOR LUMINAIRE CHARACTERIZATION Copyright 2002 IFAC 15th Triennial World Congress, Barcelona, Spain AN AUTOMATED GONIOPHOTOMETER FOR LUMINAIRE CHARACTERIZATION V. F. Muñoz, J. Gómez-de-Gabriel, J. Fernández-Lozano, R. Molina-Mesa, J.

More information

CERTIFIED TEST REPORT No

CERTIFIED TEST REPORT No Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Impact of New SSL Standards on Goniospectroradiometric Measurements

Impact of New SSL Standards on Goniospectroradiometric Measurements Impact of New SSL Standards on Goniospectroradiometric Measurements By Dr. Ðenan Konjhodžić, Application Engineer Presented by Justin Blanke, International Sales Manager Outline Goniophotometry and goniophotometer

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information