1 ANALYTICAL SCIENCES MAY 2004, VOL The Japan Society for Analytical Chemistry 865 Development of a Headspace GC/MS Analysis for Carbonyl Compounds (Aldehydes and Ketones) in Household Products after Derivatization with o-(2,3,4,5,6-pentafluorobenzyl)- hydroxylamine Naeko SUGAYA,* 1 Katsumi SAKURAI,* 1 Tomoo NAKAGAWA,* 1 Nobuhiko ONDA,* 2 Sukeo ONODERA,* 3 Masatoshi MORITA,* 4 and Masakatsu TEZUKA* 5 *1 Yokohama City Institute of Health, Takigashira, Isogo-ku, Yokohama , Japan *2 PerkinElmer Japan, Kitasaiwai, Nishi-ku, Yokohama , Japan *3 Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba , Japan *4 National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba-shi, Ibaraki , Japan *5 College of Pharmacy, Nihon University, Narashinodai, Funabashi-shi, Chiba , Japan Carbonyl compounds (aldehydes and ketones) are suspected to be among the chemical compounds responsible for Sick Building Syndrome and Multiple Chemical Sensitivities. A headspace gas chromatography/mass spectrometry (GC/MS) analysis for these compounds was developed using derivatization of the compounds into volatile derivatives with o- (2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA). For GC/MS detection, two ionization modes including electron impact ionization (EI) and negative chemical ionization (NCI) were compared. The NCI mode seemed to be better because of its higher selectivity and sensitivity. This headspace GC/MS (NCI mode) was employed as analysis for aldehydes and ketones in materials (fiber products, adhesives, and printed materials). Formaldehyde was detected in the range of N.D. (not detected) to 39 µg/g; acetaldehyde, N.D. to 4.1 µg/g; propionaldehyde, N.D. to 1.0 µg/g; n- butyraldehyde, N.D. to 0.10 µg/g; and acetone, N.D. to 3.1 µg/g in the samples analyzed. (Received February 18, 2004; Accepted April 1, 2004) Introduction Recently, Sick Building Syndrome and Multiple Chemical Sensitivities have become significant health issues. A wide range of chemicals are suspected to cause these problems, with aromatic hydrocarbons, alcohols, aldehydes, and ketones being detected in indoor air. 1,2 Among these chemicals, aldehydes, especially formaldehyde, have been widely detected in indoor air. The World Health Organization (WHO) has indicated that exposure to 0.08 ppm of formaldehyde in indoor air can cause serious health problems. 3 However, there are some reports that exposure at concentrations of less than 0.08 ppm increases allergic risks. 4,5 Thus, the need for highly sensitive analytical methods to detect formaldehyde in environmental samples is increasingly important. Another group of chemicals, ketones, are also widely used as solvents in adhesives, printing inks, and cosmetics, and are known to be mucous membrane stimulants. Furthermore, it is reported that methyl ethyl ketone may increase the neurotoxicity of other solvents. 6 A number of household products are considered to be the major source of these aldehydes and ketones. There have been several reports of analytical methods for detecting aldehydes and ketones in the air. These methods To whom correspondence should be addressed. sugayanaeko@crocus.ocn.ne.jp involve derivatization with 2,4-dinitrohydrazone (2,4-DNPH), o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA), or 2- aminoethanethiol (cysteamine), with each derivative extracted by solvents, such as hexane, and then analyzed by GC, HPLC, or GC/MS However, there have been only limited reports of highly sensitive analysis of household products that are considered to be the source of these indoor aldehydes and ketones. Sugaya et al. reported on the microanalysis of aldehydes in water by headspace GC/MS. 12 On this basis, a rapid and sensitive analytical method was developed that involves the gas elution of aldehydes and ketones into water from materials, followed by derivatization by PFBOA, and headspace gas determination by GC/MS (NCI mode). The method applied for aldehydes (formaldehyde, acetaldehyde, propionaldehyde, isoand n-butyraldehyde) and ketones (acetone, methyl ethyl ketone (MEK), and methyl iso-butyl ketone (MIBK)) in household products is reported herein. Experimental Samples Twenty four samples of household products (fiber products, adhesives, and magazines) were purchased from retail outlets in Japan in These samples were stored in sealed plastic bags immediately after purchase to avoid possible volatilization and

2 866 ANALYTICAL SCIENCES MAY 2004, VOL. 20 Table 1 Retention time and SIM monitor ions of PFBOA aldoxime and ketoxime Compound R.T./min Electron ionization (EI) Quantitative ion Qualitative ion Negative chemical ionization (NCI) Quantitative ion Qualitative ion PFBOA formaldoxime , , 225 PFBOA acetaldoxime (syn) , , 239 PFBOA acetaldoxime (anti) , , 239 PFBOA propionaldoxime (syn) , , 253 PFBOA propionaldoxime (anti) , , 253 PFBOA iso-butyraldoxime (syn) , , 267 PFBOA iso-butyraldoxime (anti) , , 267 PFBOA n-butyraldoxime (syn) , , 267 PFBOA n-butyraldoxime (anti) , , 267 PFBOA acetoneketoxime , , 233 Z-PFBOA MEKketoxime , , 247 E-PFBOA MEKketoxime , , 247 Z-PFBOA MIBKketoxime , , 275 E-PFBOA MIBKketoxime , , 275 Internal standard , water. Instrument A headspace auto-sampler (HS40XL, PerkinElmer, Inc., Shelton, CT, USA) was connected to a GC/MS (quadruple mass spectrometer, TruboMass, PerkinElmer, Inc., Shelton, CT, USA). The capillary column used was a Supelco PTE-5 (Supelco, Bellefonte, PA, USA) of 30 m length 0.25 mm i.d mm membrane thickness. Fig. 1 In situ PFBOA derivatization in a headspace vial. contamination. The front and middle pages of magazines were analyzed separately. Reagents PFBOA was purchased from Hayashi Pure Chemical Inc. Ltd. (Osaka, Japan). Aldehyde standards (10000 mg/l formaldehyde, acetaldehyde, propionaldehyde, iso- and n-butyraldehyde) were purchased from Kanto Kagaku (Tokyo, Japan), and gradually diluted with methanol to make stock solutions. Acetone (pesticide analysis grade), MEK (reagent grade), and MIBK (reagent grade) were purchased from Kanto Kagaku (Tokyo, Japan), and diluted with methanol to mg/l solutions. A mixed ketone standard stock solution containing acetone (100 mg/l), MEK (100 mg/l) and MIBK (200 mg/l) was prepared by diluting the individual stock solutions with methanol. 4-Bromofluorobenzene (1000 mg/l) was purchased from Kanto Kagaku (Tokyo, Japan), and then diluted to 50 mg/l with methanol for use as the internal standard. Methanol (pesticide analysis grade) and sodium chloride (special grade) were purchased from Kanto Kagaku (Tokyo, Japan). Blank water Commercial bottled mineral water, minimally contaminated with aldehydes and ketones, was selected and used as the blank Sampling and GC/MS condition Vials were warmed to 60 C in the headspace auto-sampler. The sampling needle and transfer lines were set at 120 C and 180 C, respectively. Pressurized by helium for 1 min at 20 psi, the injection duration of the headspace was set at 0.08 min. The ionization voltage was set at 70 ev and the ion source temperature at 200 C (EI mode) or 150 C (NCI mode); isobutane (99.99%) was used for CI analysis. The column temperature was first programmed at 60 C (2 min), then at 7 C/min to 150 C, and finally at 20 C/min to 200 C. The monitored ions for the selected ion monitoring (SIM) and retention times of the compounds are summarized in Table 1. Preparation of standard solutions and sample solutions A standard solution was made by adding 10 ml of water, 1 µl of a standard stock solution, 1 µl of an internal standard, 0.6 ml of a PFBOA water solution (1 mg/ml), and 3 g of sodium chloride into a headspace vial, and then tightly sealed with a silicone rubber septum with PTFE, as shown in Fig Sample solutions were made by adding mg samples, 10 ml of water, 1 µl of an internal standard, 0.6 ml of a PFBOA water solution (1 mg/ml), and 3 g of sodium chloride into headspace vials, and then tightly sealed with a silicone rubber septa. Results and Discussion Reaction of aldehydes and ketones with PFBOA PFBOA derivatization makes compounds sufficiently volatile for GC analysis, because it contains five fluorine atoms. The condensation reaction (Fig. 2) produces derivatives (PFBOA aldoxime and PFBOA ketoxime), even at room temperature and

3 ANALYTICAL SCIENCES MAY 2004, VOL Fig. 2 Reaction of PFBOA with aldehydes (above) and ketones (below). Fig. 4 Effect of the reaction time on the PFBOA ketoxime yield at 60 C. Mode, EI; monitoring ion, m/z , and 360 min and at 20, 40, and 60 C. The reaction was too slow at 20 and 40 C. The reaction seemed to reach equilibrium in 4 h at 60 C, as shown in Fig. 4. The EI mode was employed and m/z 181 was monitored for all ketoximes in this study. Each area of MEK and MIBK was remarkably smaller than that of acetone in Fig. 4, because the ion intensity of MEKketoxime and MIBKketoxime at m/z 181 was lower than that of acetoneketoxime by GC/MS (EI mode) and acetoneketoxime, which had a faster retention time in capillary GC analysis, and was detected more sensitively than the others. This condition was employed for subsequent experiments. Fig. 3 NCI mass chromatograms of PFBOA aldoximes (a) and ketoximes (b). 1, Formaldoxime; 2, PFBOA; 3, acetaldoxime (syn); 4, acetaldoxime (anti); 5, propionaldoxime (syn); 6, propionaldoxime (anti); 7, iso-butyraldoxime (syn); 8, iso-butyraldoxime (anti); 9, n- butyraldoxime (syn); 10, n-butyraldoxime (anti); a, acetoneketoxime; b, Z-MEKketoxime; c, E-MEKketoxime; d, Z-MIBKketoxime; e, E- MIBKketoxime. in water. The reactivity of the carbonyl group in aldehydes and ketones depends on its location within the molecule, particularly those alkyl groups adjacent to the carbonyl. In general, for alkyl groups, the carbonyl group reactivity increases as the size of the alkyl group decreases. 13 Compounds with nitrile (C=N) groups form with syn and anti isomer derivatives for all carbonyl compounds, except for formaldehyde (R 1 = H) and acetone (R 2 = R 3 = CH 3). The separation and confirmation of these isomers require capillary column GC analysis. Figure 3 shows the separation of a mixture of five aldoximes of aldehydes and a mixture of three aldoximes of aliphatic ketones by the headspace GC/MS (NCI mode). As can be seen in the mass chromatograms in Fig. 3, formaldehyde and acetone are detected as single peaks, whereas the other compounds are detected as two close peaks. 12,14 It is important to note that the syn and anti isomers of isobutyraldoxime are very close each other. Optimum reaction conditions for the condensation of PFBOA and ketones The reaction of PFBOA and ketones is known to be slower than that with aldehydes. 15 In this study, the optimum reaction condition was searched by changing at reaction times and temperatures, including the following: 30, 70, 130, 180, 240, Comparison between NCI and EI mass spectra of PFBOA ketoximes The mass spectra of EI were compared to that of NCI for PFBOA ketoximes (Figs. 5, 6). The EI mass spectra molecular ions, [M] +, were m/z 253 for acetoneketoxime, m/z 267 for MEKketoxime, and m/z 295 for MIBKketoxime. PFBOA derivatives showed a base fragment peak at m/z 181 [M ON=CH R] +. Acetoneketoxime was observed to have a fragment peak [M C 6F 5 CH 2] + at m/z 72, MEKketoxime at m/z 86, and MIBKketoxime at m/z 114. The NCI mass spectra had more simple fragmentation patterns compared with the EI mass spectra. The base fragment peak, [M ON=CH R], was at m/z 181, and the characteristic peaks of [M HF] were observed, such as acetoneketoxime at m/z 233, MEKketoxime at m/z 247 and MIBKketoxime at m/z 275. The NCI mass spectrum of PFBOA aldoxime has been reported 12 to typically consist of only a few ions: a molecular ion [M], an ion that has 20 mass units less than that of molecular ion [M HF], and the pentafluorobenzyl ion at m/z 181. Such spectra have a small number of fragment ions that are typical of aldehydes, and are therefore useful for compound detection. In this study, no molecular ion peak was observed in the NCI spectrum of PFBOA ketoxime, but the pentafluorobenzyl ion at m/z 181 was strongly detected compared to the EI mode. It was therefore determined to be useful for highly sensitive analysis. Calibration curves and detection limits for ketones Calibration curves for ketones using the headspace GC/MS (SIM) are shown in Fig. 7 (EI mode) and Fig. 8 (NCI mode). Calibration curves were calculated from peak areas using the internal standard. The total peak areas of all isomers were used with the exception of acetone. It is worth noting that acetone was detected even in blank water, and therefore the calibration curves did not go through the original point. Using EI, acetone had linear calibration curves within a range of µg/l; MEK, µg/l; and MIBK,

4 868 ANALYTICAL SCIENCES MAY 2004, VOL. 20 Fig. 7 Calibration curves of ketones (EI). (a) Acetone, (b) MEK, (c) MIBK. Fig. 5 EI mass spectra of PFBOA ketoximes. Fig. 8 Calibration curves of ketones (NCI). (a) Acetone, (b) MEK, (c) MIBK. Fig. 6 NCI mass spectra of PFBOA ketoximes. µg/l. Acetone, MEK and MIBK had good correlation coefficients ( ). Using NCI, acetone and MEK had linear calibration curves within the range of µg/l, and MIBK of µg/l. The correlation coefficients were good ( ). The determination limits and standard deviations of each compound given in Table 2 were defined according to Method for determination of tetra- through octa-chlorodibenzo-pdioxins, tetra- through octa-chlorodibenzofurans and coplanar polychlorobiphenyls in industrial water and waste water (JIS K0312). 16 The determination limits of ketones by headspace GC/MS (SIM) were acetone, 0.2 µg/l; MEK, 0.6 µg/l; MIBK, 1.2 µg/l, respectively, for the EI mode. However, the determination limits by the NCI mode were acetone, 0.2 µg/l; MEK, 0.2 µg/l; and MIBK, 0.4 µg/l, respectively. The NCI mode is more sensitive, but the determination limit for acetone is similar. This is because acetone was detected in blank water. It is possible to reduce the determination limit for the NCI mode if the blank level is reduced. Application to household products Because it is important to investigate the source of compounds with carbonyl groups in indoor air to specify the cause of health

5 ANALYTICAL SCIENCES MAY 2004, VOL Table 2 Determination limits and standard deviations of ketones (n = 6) Compound Determination limit Electron ionization (EI) Standard deviation RSD, % a Negative chemical ionization (NCI) Determination limit Standard deviation RSD, % a Acetone MEK MIBK a. Relative standard deviation. Table 3 Ketone concentrations in household products No. Sample Material Acetone MEK MIBK Fig. 9 NCI mass fragmentograms of sample No. 12 (a) and sample No. 6 (b). 1, Formaldoxime; 2, PFBOA; 3, acetaldoxime (syn); 4, acetaldoxime (anti); 5, propionaldoxime (syn); 6, propionaldoxime (anti); 9, n-butyraldoxime (syn); 10, n-butyraldoxime (anti); a, acetoneketoxime. problems, such as Sick Building Syndrome and Multiple Chemical Sensitivities, an analytical application of household products was performed. Although household products contain various chemicals, a highly sensitive, high selectively headspace GC/MS (NCI mode) could remove interferences, and was applied to aldehyde and ketone quantitative analysis. The method uses a small amount of samples ( mg), and can analyze up to the 0.01 µg/g level. Figure 9 shows the mass fragmetograms of aldehydes and ketones in household products. In Fig. 9, m/z 181 was monitored as a quantitative ion of aldehydes in a magazine (sample No. 12) and m/z 233 was monitored as a qualitative ion of acetone in an adhesive (sample No. 6). Ketones in household products Table 3 gives the results for the determination of ketones in household products. Acetone in the samples was detected within the level of N.D. 4.1 µg/g. However, MEK and MIBK were not detected in any of the samples examined. Aldehydes in household products Table 4 gives the results for the determination of aldehydes in household products. The formaldehyde contents in clothes and adhesives, among household products, are regulated in Japan in an effort to prevent skin damage from formaldehyde. 17 In the analyzed samples, formaldehyde was detected at the level of N.D. to 39 µg/g; acetaldehyde, N.D. to 4.1 µg/g; propionaldehyde, N.D. to 1.0 µg/g; and n-butyraldehyde, N.D. to 0.28 µg/g, while isobutyraldehyde was not detected. Formaldehyde was detected from most of the samples, and it was confirmed that various household products contain formaldehyde. In printed materials, it was found that a significant amount of aldehyde was present: formaldehyde, µg/g; propionaldehyde, µg/g; and n- butyraldehyde, N.D µg/g, respectively. Printed materials are thought to be sources of these indoor aldehydes. The source of formaldehyde in printed materials can be from both the ink and paper. The analysis of front pages of 1 Adhesive Starch N.D. N.D. N.D. 2 Adhesive Starch 0.21 N.D. N.D. 3 Adhesive Starch N.D. N.D. N.D. 4 Adhesive Acrylic adhesive, 0.08 N.D. N.D. 5 Adhesive Acrylic adhesive, 0.15 N.D. N.D. flavor, aloe extract 6 Adhesive Acrylic adhesive, 3.1 N.D. N.D. 7 Magazine Paper, ink N.D. N.D. N.D. 8 Magazine Paper, ink N.D. N.D. N.D. 9 Magazine Paper, ink N.D. N.D. N.D. 10 Magazine Paper, ink N.D. N.D. N.D. 11 Magazine Paper, ink N.D. N.D. N.D. 12 Magazine Paper, ink N.D. N.D. N.D. 13 Magazine Paper, ink 0.07 N.D. N.D. 14 Magazine Paper, ink N.D. N.D. N.D. 15 Magazine Paper, ink N.D. N.D. N.D. 16 Magazine Paper, ink N.D. N.D. N.D. 17 Magazine Paper, ink 0.30 N.D. N.D. 18 Magazine Paper, ink N.D. N.D. N.D. 19 Clothes Cotton (100%) N.D. N.D. N.D. 20 Clothes Cotton, nylon 0.04 N.D. N.D. 21 Clothes polyurethane Polyester (100%) 0.31 N.D. N.D. 22 Clothes Polyester (100%) N.D. N.D. N.D. 23 Clothes Cotton (100%) N.D. N.D. N.D. 24 Clothes Cotton (50%), polyester (50%) 0.03 N.D. N.D. Unit: µg/g. N.D.: Not detected. magazines showed formaldehyde at a level of µg/g (mean of 1.6 µg/g), whereas the middle pages showed a level of µg/g (mean of 6.02 µg/g). Conclusions We developed a rapid and sensitive microanalysis method for aldehydes and ketones in household products. The method includes headspace GC/MS with negative chemical ionization after derivatizing the carbonyl compounds with PFBOA, after eluting into water (60 C). The headspace GC/MS (NCI mode) that employs PFBOA is a highly sensitive analytical method that resists influences by interfering substances present in large quantities in samples. Consequently, this technique was

6 870 ANALYTICAL SCIENCES MAY 2004, VOL. 20 Table 4 Aldehyde concentrations in household products No. Sample Material FA AA PA iso-ba n-ba 1 Adhesive Starch, fungicides N.D. N.D. N.D. 2 Adhesive Starch, 9.6 N.D. N.D. N.D. N.D. fungicides 3 Adhesive Starch N.D. N.D. N.D. 4 Adhesive Acrylic N.D. N.D. N.D. 5 Adhesive adhesive, Acrylic N.D. 1.8 N.D. N.D. N.D. adhesive, flavor, aloe extract 6 Adhesive Acrylic adhesive, N.D. N.D. N.D. 7 Magazine Paper, ink N.D. N.D. 8 Magazine Paper, ink N.D. N.D. 9 Magazine Paper, ink N.D. N.D. 10 Magazine Paper, ink N.D. N.D. 11 Magazine Paper, ink N.D. N.D. 12 Magazine Paper, ink N.D Magazine Paper, ink N.D. N.D. 14 Magazine Paper, ink N.D. N.D. 15 Magazine Paper, ink N.D Magazine Paper, ink N.D Magazine Paper, ink N.D. N.D. 18 Magazine Paper, ink N.D Clothes Cotton (100%) N.D. N.D. N.D. 20 Clothes Cotton, nylon 0.64 N.D. N.D. N.D. N.D. polyurethane 21 Clothes Polyester (100%) N.D. N.D. N.D. 22 Clothes Polyester N.D. N.D. N.D. (100%) 23 Clothes Cotton (100%) N.D. N.D. N.D. 24 Clothes Cotton (50%), polyester (50%) N.D. N.D. N.D. Unit: µg/g. N.D.: Not detected. FA, formaldehyde; AA, acetaldehyde; PA, propionaldehyde; iso-ba, iso-butyraldehyde; n-ba, n-butyraldehyde. expected to be widely applicable to the analysis of such materials as food and biological samples, as well as in the analysis of household products. References 1. Ministry of Health and Welfare, Japan, National survey of volatile organic compounds in the indoor environment (in Japanese), 1999, Ministry of Health and Welfare, Environmental Health Bureau, Planning Division, Environmental Chemical Safety, Japan. 2. J. Zheng, T. Tanaka, T. Tanaka, and Y. Kobayashi, J. Environ. Chem. (in Japanese), 2000, 10, World Health Organization, Air quality guidelines, 1999, World Health Organization (WHO), Geneva. 4. M. H. Garrett, M. A. Hooper, B. M. Hooper, P. R. Rayment, and M. J. Abramson, Allergy, 1999, 54, F. Wantke, C. M. Demmer, P. Tappler, M. Gotz, and R. Jarisch, Clin. Exp. Allergy, 1996, 26, M. Ikeda, in Industrial Poisoning Handbook, Enlarged Edition (in Japanese), ed. S. Goto, M. Ikeda, and I. Hara, 1994, Ishiyaku Publishers, Inc., Tokyo, K. Kuwata, M. Uebori, H. Yamasaki, Y. Kuge, and Y. Kiso, Anal. Chem., 1983, 55, X. Zhou and K. Mopper, Environ. Sci. Technol., 1990, 24, A. Yasuhara and T. Shibamoto, J. Assoc. Off. Anal. Chem., 1989, 72, Y. Mori, S. Setsuda, S. Goto, S. Onodera, S. Nakai, and H. Matsushita, J. Health Sci. (in Japanese), 1999, 45, J. A. Koziel, J. Noah, and J. Pawliszyn, Environ. Sci. Technol., 2001, 35, N. Sugaya, T. Nakagawa, K. Sakurai, M. Morita, and S. Onodera, J. Health Sci., 2001, 47, S. Umezawa, in Yukikagaku I (Organic Chemistry I, in Japanese), 1961, Maruzen Co., Ltd., Tokyo, Y. Mori, K. Tsuji, S. Setsuda, S. Goto, S. Onodera, and H. Matsushita, Jpn. J. Toxicol. Environ. Health (in Japanese), 1996, 42, K. Kobayashi, M. Tanaka, and S. Kawai, J. Chromatogr., 1980, 187, JIS K0312, Method for determination of tetra- through octa-chlorodibenzo-p-dioxins, tetra- through octachlorodibenzofurans and coplanar polychlorobiphenyls in industrial water and waste water, 1999, Japanese Industrial Standards Committee, Tokyo. 17. Low for the Control of Household Products Containing Harmful Substances, Low No.112, 1973, Japan.

Analysis of Aldehydes in Water by Head Space-GC/MS

Analysis of Aldehydes in Water by Head Space-GC/MS Journal of Health Science, 47(1) 21 27 (2001) 21 Analysis of Aldehydes in Water by Head Space-GC/MS Naeko Sugaya,*, a Tomoo Nakagawa, a Katsumi Sakurai, a Masatoshi Morita, b and Sukeo Onodera c a Yokohama

More information

Original. Tomoo Nakagawa*, Naeko Sugaya*, Katsumi Sakurai*, Junichi Nakagawa**, Koichi Usukura***, Nobuhiko Onda*** and Koichi Oguma****

Original. Tomoo Nakagawa*, Naeko Sugaya*, Katsumi Sakurai*, Junichi Nakagawa**, Koichi Usukura***, Nobuhiko Onda*** and Koichi Oguma**** Chromatography, Vol.25 No.1 (24) Original Simultaneous Detection of Endocrine Disruptors of 4 Nonyl Phenols and 4 Octyl Phenols in Commodity Products Using Positive Chemical Ionization Gas Chromatography/Mass

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010 METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010 BIOCHEMISTRY The MEK is presented as a colorless liquid odor similar to that of acetone, is volatile and potentially explosive. The

More information

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION. APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Author: Kira. Yang PerkinElmer, Inc. Shanghai, China Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS Introduction

More information

GC Application Note. Determination of C2-C12 aldehydes in water by SPME on-fiber derivatization.

GC Application Note. Determination of C2-C12 aldehydes in water by SPME on-fiber derivatization. GC Application Note Determination of C2-C12 aldehydes in water by SPME on-fiber derivatization and GC/MS www.palsystem.com Determination of C2-C12 aldehydes in water by SPME on-fiber derivatization and

More information

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes

More information

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Application Note Environmental Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Authors Ye Kong and Zhe Cao Agilent Technologies,

More information

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS PAGE: 1 of 18 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Analysis of BTEX in Natural Water with SPME

Analysis of BTEX in Natural Water with SPME Analysis of BTEX in Natural Water with SPME Application Note Environmental Author Giordano Vassalli Sezione Protezione Aria Introduction Benzene, toluene, ethylbenzene and xylene (BTEX) isomers are monocyclic

More information

GC/MS Analysis Laboratory Report

GC/MS Analysis Laboratory Report Report No.: J-123456 Date: March 1, 2016 P.O. No.: PO 1234A GC/MS Analysis Laboratory Report Prepared for: Mr. Customer Name Company Name, Inc. 123 First St. Your City, State Prepared by: Bradley J. Cline

More information

Determination Spectrometry. of Serum Glucose by Isotope Dilution Mass. National Chemical Laboratory for Industry, Tsukuba, Ibaraki 305

Determination Spectrometry. of Serum Glucose by Isotope Dilution Mass. National Chemical Laboratory for Industry, Tsukuba, Ibaraki 305 ANALYTICAL SCIENCES OCTOBER 1988, VOL. 4 487 Determination Spectrometry of Serum Glucose by Isotope Dilution Mass Akiko TAKATSU and Sueo NISHI National Chemical Laboratory for Industry, Tsukuba, Ibaraki

More information

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction 1. Application 1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction Parameters and Codes: EDB and DBCP, whole water recoverable, O-3120-90 Parameter (µg/l)

More information

Equilibrated Vapor Concentrations for Bicomponent Organic Solvents

Equilibrated Vapor Concentrations for Bicomponent Organic Solvents J Occup Health 1998; 40: 13 136 Journal of Occupational Health Equilibrated Vapor Concentrations for Bicomponent Organic Solvents Hajime HORI 1 and Isamu TANAKA 1 Department of Environmental Management

More information

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* EPA Method 8315A UCT Part Number: EUC1812M15 (Unendcapped C18-2000 mg/15 ml cartridge) March 2013 Method

More information

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food

More information

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD Kamarruddin ASRI 1, Robert A. ANDERSON 2 1 Department of Chemistry, Jalan

More information

Headspace Solid Phase Microextraction/Gas Chromatography for Determination of Aldehydes

Headspace Solid Phase Microextraction/Gas Chromatography for Determination of Aldehydes Headspace Solid Phase Microextraction/Gas Chromatography for Determination of Aldehydes Winyu Chitsamphandhvej 1*, Panthira Ketkeaw 1, Praphatpong Nonsung 1 and Pichan Chiamchunkoop 1 ABSTRACT A headspace

More information

Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance Liquid Chromatography

Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance Liquid Chromatography ANALYTICAL SCIENCES FEBRUARY 2015, VOL. 31 99 2015 The Japan Society for Analytical Chemistry Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance

More information

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Kitsada Pitija, PhD Tinnakorn Srisedkha, PhD Chanchira Wiwatsamretkun PerkinElmer Inc. Bangkok, Thailand Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline

More information

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003 ALCOHOLS IV 1403 (1) HOCH 2 CH 2 OCH 3 MW: (1) 76.09 CAS: (1) 109-86-4 RTECS: (1) KL5775000 (2) HOCH 2 CH 2 OCH 2 CH 3 (2) 90.12 (2) 110-80-5 (2) KK8050000 (3) HOCH 2 CH 2 O(CH 2 ) 3 CH 3 (3) 118.17 (3)

More information

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Method of determination of phtalates in spirituous beverages by gaschromatography/mass OIV-MA-BS-33 Method of determination of phtalates in spirituous beverages by gas-chromatography/mass Type IV method 1. SCOPE OF APPLICATION This method applies to the detection and assay of some phthalates

More information

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System Application Note Authors Wenwen Wang, Zhe Cao Agilent Technologies, Inc. No.3, Wang Jing Bei Lu, Chao Yang District,

More information

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES J Kouzaki 1*, S Sato 1, S Nakai 1, Y Shirasuna 2, K Hirano 2 1 Graduate School of Environmental and Information

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(6):392-399 Estimation of epichlorohydrin content in pharmaceutical

More information

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Sensitive Detection of 2-MIB and Geosmin in Drinking Water Sensitive Detection of -MIB and Geosmin in Drinking Water Application Note Environmental Author Yean-Woong You Agilent Technologies, Inc. Seoul, Korea Abstract An automated SPME extraction method for easy

More information

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Lee Marotta Tom Kwoka David Scott Miles Snow Toby Astill PerkinElmer, Inc. Shelton, CT Fast, Quantitative Analysis of Residual Solvents in

More information

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography Introduction ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings.

More information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,

More information

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017 High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017 Y.J. Mange D.B. Milligan V.S. Langford B.J. Prince M. Perkins C. Anderson T. Wilks Who is using Syft Technologies

More information

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities

More information

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS PO-CON1731E Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS ASMS 2017 TP-295 Hui Xian Crystal Yeong 1, Stephany Olivia 2, Lai Chin Loo 1 1 Application

More information

A Study on the Peak Separation of Acetone and Acrolein Based on High-Performance Liquid Chromatography (HPLC) Method

A Study on the Peak Separation of Acetone and Acrolein Based on High-Performance Liquid Chromatography (HPLC) Method The Peak Separation of Acetone and Acrolein Bull. Korean Chem. Soc. 009, Vol. 30, No. 9 0 A Study on the Peak Separation of Acetone and Acrolein Based on High-Performance Liquid Chromatography (HPLC) Method

More information

Volatile Organic Compounds in Every Day Food

Volatile Organic Compounds in Every Day Food Volatile Organic Compounds in Every Day Food Application Note Abstract Volatile Organic Compounds (VOCs) have been analyzed in drinking water and pharmaceuticals extensively in recent years. Now, VOCs

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer 2000 The Japan Society for Analytical Chemistry 627 Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer Sadao NAKAMURA,* Masahiko TAKINO,* and Shigeki DAISHIMA**

More information

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Application Note Forensic Toxicology and Drug Testing Author Jared Bushey Agilent Technologies, Inc. 285 Centerville

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform ( 염화비닐, 아크릴로니트릴, 브로모포름 ) with Static and Dynamic Headspace GC/MS Roger Bardsley, Applications Chemist;

More information

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler No. SSI-GC- Gas Chromatography No. GC- Analysis of Residual Solvents in Pharmaceuticals (USP) with Shimadzu GC- Plus and HS- Headspace Sampler Introduction Organic solvents are routinely used in manufacturing

More information

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Method 8030 is used to determine the concentration of the following volatile organic compounds: Compound Name

More information

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source Application Note Environmental Authors Peter Gautschi and Harry Prest Senior Application Scientist

More information

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System Application Note Residual Solvent Analysis of USP Method Residual Solvents on the Agilent 889 GC System Author Lukas Wieder, Jie Pan, and Rebecca Veeneman Agilent Technologies, Inc. 8 Centerville Road

More information

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan. Determination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection Sadao Nakamura,* Takashi Yamagami and Shigeki

More information

DETERMINATION OF PHTHALATES FROM BOTTLED WATER BY GC-MS

DETERMINATION OF PHTHALATES FROM BOTTLED WATER BY GC-MS DETERMINATION OF PHTHALATES FROM BOTTLED WATER BY GC-MS IRINA DUMITRAȘCU 1,2 ABSTRACT- Determination of phthalates from bottled by GC-MS. Phthalates are ubiquitous pollutants in the environment, due to

More information

Separation and Determination of Carbonyl Compounds in Indoor Air Using Two-Step Gradient Capillary Electrochromatography

Separation and Determination of Carbonyl Compounds in Indoor Air Using Two-Step Gradient Capillary Electrochromatography 2004 The Japan Society for Analytical Chemistry 1691 Separation and Determination of Carbonyl Compounds in Indoor Air Using Two-Step Gradient Capillary Electrochromatography Yong-Lai FENG and Jiping ZHU

More information

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Application Note Environmental Author Suli Zhao, Andy Zhai Agilent Technologies Co., Ltd. 412 Yinglun Road

More information

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2), ISSN: 0973-4945; CODEN ECJHAO E-Journal of Chemistry http://www.e-journals.net 2010, 7(2), 629-635 Low-level Determination of Residual Methyl Methane Sulfonate and Ethyl Methane Sulfonate in Pharmaceuticals

More information

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer Application Note By: Anne Jurek Abstract This application note presents

More information

ACETONE IN URINE BY GC/MS Headspace Code GC10110

ACETONE IN URINE BY GC/MS Headspace Code GC10110 ACETONE IN URINE BY GC/MS Headspace Code GC10110 BIOCHEMISTRY The acetone or dimethyl ketone is a product which falls into the biochemical physiological small amounts are formed as a product of the metabolism

More information

[ a ppl ic at ion no t e ]

[ a ppl ic at ion no t e ] [ a ppl ic at ion no t e ] Fast A nalysis of A ldehydes and K etones by A C Q U I T Y U P L C Mark E. Benvenuti Waters Corporation, Milford, MA, USA INT RO DUC T ION Aldehydes and ketones are products

More information

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology APPLICATION NOTE Gas Chromatography Author: David Scott PerkinElmer, Inc. Shelton, CT Residual Solvents in Pharmaceuticals by USP Chapter Methodology Introduction The synthesis of active pharmaceutical

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Application Note By: Nathan Valentine Abstract The US EPA developed Method 524.2¹, Measurement

More information

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Application Note Food Authors Nobuo Ochiai and Kikuo Sasamoto GERSTEL K.K. 2-13-18 Nakane

More information

GC/MS Application Note

GC/MS Application Note GC/MS Application Note Determination of Odor Compounds in Water by SPME Arrow Gas Chromatography/Mass Spectrometry www.palsystem.com Determination of Odor Compounds in Water by SPME Arrow Gas Chromatography/Mass

More information

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations OUTLINE OF METHOD This gas chromatography/mass spectrometry (GC/MS) method provides

More information

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),

More information

Application News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

Application News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS HS-20 & GCMS-QP2010Ultra Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS Introduction Volatile Organic Compounds (VOCs) refer to a group

More information

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Introduction Fire investigation involves many different types of analyses from crime scene

More information

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS 1. Scope This method is applicable for determining the presence

More information

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection Trade Science Inc. September 2009 Volume 8 Issue 3 ACAIJ, 8(3) 2009 [346-349] Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization

More information

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,

More information

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Application Note No. 033 Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Ryoichi Sasano*, Takayuki

More information

Analytical Trap Comparison for USEPA Method 8260C

Analytical Trap Comparison for USEPA Method 8260C Analytical Trap Comparison for USEPA Method 8260C Application Note Abstract Purge and trap concentration is a technique that is used for the analysis of Volatile Organic Compounds (VOCs). The major component

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT AppNote 6/2014 Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones Fred D. Foster, John R. Stuff, Kurt Thaxton, Edward A. Pfannkoch Gerstel, Inc., 701 Digital

More information

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography 2003 The Japan Society for Analytical Chemistry 1365 Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography Mohammad A. MOTTALEB,* Mohammad

More information

Application Note. Abstract. Authors. Introduction

Application Note. Abstract. Authors. Introduction Multiple Headspace Extraction for the Quantitative Determination of Residual Monomer and Solvents in Polystyrene Pellets Using the Agilent 7697A Headspace Sampler Application Note Authors Wenwen Shen and

More information

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note. Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID Application Note Volatile Organic Compounds (VOCs) Author Andrew Jones Activated

More information

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID Asian Journal of Chemistry Vol. 21, No. 3 (2009), 1739-1746 Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID PRAVEEN KUMAR BALIYAN*, R.P.

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application Pharmaceuticals Author Roger L. Firor Agilent Technologies, Inc. 2850 Centerville

More information

Method - Determination of aromatic amines in mainstream cigarette smoke

Method - Determination of aromatic amines in mainstream cigarette smoke British American Tobacco Group Research & Development Method - Determination of aromatic amines in mainstream cigarette smoke 1 SCOPE OF APPLICATION The method is applicaple to quantitative determination

More information

Reactions of Vinyl Chloride and Methanol in a Quadrupole Ion Trap Mass Spectrometer during VOC Analysis

Reactions of Vinyl Chloride and Methanol in a Quadrupole Ion Trap Mass Spectrometer during VOC Analysis Environ. Sci. Technol. 1999, 33, 1528-1533 Reactions of Vinyl Chloride and Methanol in a Quadrupole Ion Trap Mass Spectrometer during VOC Analysis LIANGQIAO BIAN, EARL G. ALLEY,, AND BERT C. LYNN, JR.*,,

More information

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS Application Note Energy and Fuels - Biofuels Authors Ron Honnold, Ph.D. and Robert Kubas Agilent Technologies, Inc. Santa Clara, CA

More information

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD Application Note Energy & Fuels Authors Mingji Cao and Zhaoxia Liu Shanghai SECCO Petrochemical Co., Ltd.

More information

2401 Gas (liquid) Chromatography

2401 Gas (liquid) Chromatography 2401 Gas (liquid) Chromatography Chromatography Scheme Gas chromatography - specifically gas-liquid chromatography - involves a sample being vaporized and injected onto the head of the chromatographic

More information

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System Application Note Abstract The Massachusetts Department of Environmental Protection (MassDEP) developed the Method

More information

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)

More information

Benzoylecgonine in Urine by SAMHSA GC/MS

Benzoylecgonine in Urine by SAMHSA GC/MS application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Benzoylecgonine in Urine by SAMHSA GC/MS Introduction The United States Department

More information

Formaldehyde Fluorescent Detection Kit

Formaldehyde Fluorescent Detection Kit K-ASSAY KAMIYA BIOMEDICAL COMPANY KAMIYA BIOMEDICAL COMPANY Formaldehyde Fluorescent Detection Kit For detection in human urine and tissue culture media Cat. No. KT-723 For Research Use Only. Not for Use

More information

VOC TEST REPORT AgBB

VOC TEST REPORT AgBB Bostik SA 253 rue du Président Wilson 93211 La Plaine St Denis Cedex FRANCE Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT

More information

Author. Abstract. Introduction

Author. Abstract. Introduction Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent

More information

Determination of Carbonyl Compounds in Workplace Air

Determination of Carbonyl Compounds in Workplace Air Determination of Carbonyl Compounds in Workplace Air Huang Xiongfeng, Xu Qun, and Jeffrey Rohrer Thermo Fisher Scientific, Shanghai, People s Republic of China; Thermo Fisher Scientific, Sunnyvale, CA,

More information

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 66 Triple Quadrupole LC/MS System Application Note Environmental Authors Don Noot, Matthew Noestheden, and Ralph Hindle Vogon

More information

Report AFK0242/18 TABLE OF CONTENTS

Report AFK0242/18 TABLE OF CONTENTS Client: Blue Dent Dental OS: 0161/0211-18 Contact: Rafael Gomes E-mail: rafael@bluedent.com.br Phone: (19) 3563-2222 Address: Rua Joaquim Jorge Port, 1272 City/State: Pirassununga/SP Zip Code: 13636-142

More information

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK

More information

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 77A mini TD and 70A GC Application Note Environmental Authors Tingting Bu, Xiaohua Li Agilent Technologies (Shanghai) Co.,

More information

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China Rapid Deteration of Eight Related Aromatic Acids in the p-phthalic Acid Mother Liquid Using an Agilent 126 Infinity LC System and an Agilent Poroshell 12 SB-C18 Column Application Note Author Xinlei Yang

More information

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION METHOD 80 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION 1.0 SCOPE AND APPLICATION 1.1 Method 80 may be used to determine the concentration of acetonitrile (CAS No. 75-05-8) in aqueous

More information

ORGANOPHOSPHORUS PESTICIDES 5600

ORGANOPHOSPHORUS PESTICIDES 5600 ORGANOPHOSPHORUS PESTICIDES 5600 Formula: Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1 METHOD: 5600, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : Table 2 NIOSH: Table 2 ACGIH: Table 2 PROPERTIES:

More information

Study of Residual Solvents in Various Matrices by Static Headspace

Study of Residual Solvents in Various Matrices by Static Headspace Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.

More information

Laszlo Hollosi, Hamide Senyuva, Klaus Mittendorf, Thermo Fisher Scientific, Dreieich, Germany. Sample + IS. Extraction/Derivatization

Laszlo Hollosi, Hamide Senyuva, Klaus Mittendorf, Thermo Fisher Scientific, Dreieich, Germany. Sample + IS. Extraction/Derivatization Determination of Acrolein and Other Process Contaminants in Beer, Wine, and Potato Chip Matrices by Liquid Chromatography-Single Quadrupole Mass Spectrometry Method 63558 Laszlo Hollosi, Hamide Senyuva,

More information

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP Application Note Joseph M. Levy Michael Kraft Abstract Agilent Equipment 7890A

More information

FORMIC ACID in URINE by GC/MS-headspace - Code GC74010

FORMIC ACID in URINE by GC/MS-headspace - Code GC74010 FORMIC ACID in URINE by GC/MS-headspace - Code GC74010 BIOCHEMISTRY The Methanol is used in the production of cellulose, synthetic resins, formaldehyde, acetic acid and fuel. The route of exposure is more

More information

Characteristic of Calibration Curve Resulting from the Use of 2 H-analogs of the Analyte as Internal Standards--Methamphetamine Example

Characteristic of Calibration Curve Resulting from the Use of 2 H-analogs of the Analyte as Internal Standards--Methamphetamine Example FORENSIC SCIENCE JOURNAL SINCE 00 Forensic Science Journal 004;3:59-70 Characteristic of Calibration Curve Resulting from the Use of H-analogs of the Analyte as Internal Standards--Methamphetamine Example

More information

Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material

Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material ANALYTICAL SCIENCES JUNE 2015, VOL. 31 463 2015 The Japan Society for Analytical Chemistry Original Papers Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material Taichi YAMAZAKI,

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

High Purity Chromasolv Solvents

High Purity Chromasolv Solvents Research Chemicals High Purity Chromasolv Solvents Part of Honeywell Research Chemical s Exclusive Riedel-de Haën Brand Portfolio The Chromasolv family of solvents are used in a variety of analytical applications

More information