Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Size: px
Start display at page:

Download "Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK"

Transcription

1 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Biochemistry Department Macclesfield District General Hospital Victoria Road Macclesfield SK10 3BL United Kingdom Contact: Jane E Clarke Tel: +44 (0) Fax: +44 (0) jane.clarke11@nhs.net Website: Testing performed at the above address only DETAIL OF ACCREDITATION General Biochemistry HUMAN BODY FLUIDS diagnosis. Quantification of: Albumin Glenbio reagent - BCP(Bromocresol Purple) Ammonia Thermo Scientific Infinity reagent - Direct Enzymatic Alkaline-Phosphatase Beckman Olympus reagent - ALP / Beckman calibrator P-NPP IFCC ALT AST Beckman Olympus reagent - ALT/ IFCC 2-oxoglutarate Beckman Olympus reagent - AST/ IFCC 2-oxoglutarate (Urine also) Amylase Beckman Olympus reagent - Amylase/IFCC with alphaglucosidase Bicarbonate Beckman Olympus reagent - CO2/ NIST PEP Bile Acids Sentinel Diagnostics reagent - enzymatic colourimetric (formazan dye) Assessment Manager: MP Page 1 of 6

2 (urine also) Calcium Beckman Olympus reagent - Calcium / Arsenazo III Carbamazepine Beckman Olympus reagent - enzymatic spectrophotometric (Urine also) Chloride Beckman Olympus reagent - Indirect ISE Cholesterol Creatine kinase Beckman Olympus reagent - NIST homogenous Beckman Olympus reagent - IFCC 6GP (Urine also) Creatinine Beckman Olympus reagent enzymatic CRP Beckman Olympus reagent - IFCC Digoxin Beckman Olympus reagent Immunoturbidimetric method Direct Bilirubin Gentamicin Beckman Olympus reagent - DPD azobilirubin accel Beckman Olympus gentamicin reagent enzyme immunoassay (CSF also) Glucose Beckman Olympus reagent - hexokinase GGT Beckman Olympus reagent - IFCC enzymatic HDL-Cholesterol Beckman Olympus reagent - enzymatic Immunoglobulins (IgG, IgA, IgM) Beckman Olympus reagents - Immunoturbidimetric Assessment Manager: MP Page 2 of 6

3 Iron Beckman Olympus Reagent TPTZ colorimetric Plasma only Lactate Beckman Olympus reagent - Lactate to pyruvate LDH Beckman Olympus reagent - IFCC Pyruvate to lactate Lithium Thermo Scientific Infinity reagent - Porphyrin spectrophotometric (Urine also) Magnesium Beckman Olympus reagent - Xylidyl blue method Urine only Microalbumin Beckman Olympus reagent - Turbidimetric Paracetamol Beckman Olympus reagent Enzymatic Phenytoin Beckman Olympus reagent - Enzymatic spectrophotometric Phenobarbitone Beckman Olympus reagent - Enzymatic spectrophotometric (Urine also) Phosphate Beckman Olympus reagent - Enzymatic spectrophotometric (Urine also) Potassium Beckman Olympus - Indirect ISE Urine only Protein Beckman Olympus urine reagent - Pyrogallol Red Salicylate Siemens reagent enzymatic Assessment Manager: MP Page 3 of 6

4 (Urine also) Sodium Beckman Olympus reagent - Indirect ISE Theophylline Beckman Olympus reagent - Enzymatic immunoassay Tobramycin Thermo Scientific CEDIA Tobramycin II reagent - Enzymatic immunoassay Total Bilirubin Beckman Olympus reagent - DPD azobilirubin + accel (CSF also) Total Protein Beckman Olympus reagent - Pyrogallol Red Transferrin Beckman Olympus Transferrin reagent Immunoturbidimetric Triglyceride Beckman Olympus T reagent enzymatic method IDMS traceable. (Urine also) Urate Beckman Olympus reagent Trinders (Urine also) Urea Beckman Olympus reagent - kinetic UV Valproic Acid Beckman Olympus reagent - enzymatic immunoassay Vancomycin Thermo Scientific QMS Reagent Immunoturbidimetric Urine HcG (Pregnancy Testing) SOP B100 by competitive binding immunoassay using Biomerieux Bionexia HcG cassettes Assessment Manager: MP Page 4 of 6

5 Blood HbA1c SOP B92 by Affinity HPLC using Menarini 9210 Blood Blood Gas & Co-Oximetry SOP B78 using IL GEM 4000 Serum and urine Detection of normal and abnormal electrophoretic patterns and quantitation of Monoclonal Protein Bands SOPs B101, B101B, B101C and B79 by gel electrophoresis using Sebia Hydrasys and capillary electrophoresis using Sebia Capillarys II Flex Piercing Analyser Sweat Chloride SOP B86 by coulometry using Jenway Chloride Meter CSF Xanthochromia SOP B84 by spectrophotometry using Cecil Spectrophotometer Immunoassay Serum / plasma (unless otherwise ) diagnosis. Quantification of: BNP SOP CBIA 001 using Beckman Coulter DxI and Alere two-site immunoenzymatic sandwich assay CA-125 CEA Cortisol Ferritin Folate FT4 FSH FT3 hcg SOP CBIA 001 using Beckman Coulter DxI and Beckman chemiluminscent immunoassay kits Assessment Manager: MP Page 5 of 6

6 Serum / plasma (unless otherwise ) Serum / plasma (unless otherwise ) LH Oestradiol Prolactin Progesterone Immunoassay (cont d) diagnosis. Quantification of (cont d): PSA Troponin TSH (using Beckman Access TSH (3 rd IS) reagent Vitamin B12 SOP CBIA using Beckman Coulter DxI and Beckman chemiluminscent immunoassay kits SOPs B1 and B13 by competitive binding using Beckman Coulter DxI with specific reference to: Procalcitonin SOP B62 using Biomerieux Vidas 3 END Assessment Manager: MP Page 6 of 6

JAPANESE CHEMISTRY AND IMMUNODIAGNOSTICS MARKETS. Table of Contents

JAPANESE CHEMISTRY AND IMMUNODIAGNOSTICS MARKETS. Table of Contents JAPANESE CHEMISTRY AND IMMUNODIAGNOSTICS MARKETS Introduction Table of Contents Worldwide Market and Technology Overview A. Major Routine Chemistry Tests 1. Albumin 2. Alkaline Phosphatase 3. ALT/SGPT

More information

Future US Clinical Chemistry and Immunodiagnostics Market: Growth Opportunities and Business Expansion Strategies.

Future US Clinical Chemistry and Immunodiagnostics Market: Growth Opportunities and Business Expansion Strategies. Future US Clinical Chemistry and Immunodiagnostics Market: Growth Opportunities and Business Expansion Strategies Introduction Table of Contents Worldwide Market and Technology Overview A. Major Routine

More information

Product Catalogue 2016

Product Catalogue 2016 Product Catalogue 2016 CLINICHEM Ltd H-1117 Budafoki street 111-113 Budapest, Hungary Content Immunochemistry reagents Standards, controls Concentrated reagents (NEW) Supplying quality for clinical laboratories

More information

BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE)

BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE) PRODUCT LIST 01 02 03 04 05 BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE) QUALITY CONTROLS ELECTRODES TABLE OF CONTENTS BLOOD GAS / ISE / CO-OXIMETRY ANALYZERS Siemens-Bayer (Ciba-Corning / Chiron) 238,248,348

More information

Miura 120 photometric tests per hour, up to 180 tests per hour with integrated ise module. Miura 200

Miura 120 photometric tests per hour, up to 180 tests per hour with integrated ise module. Miura 200 F A M I L Y R A N D O M A C C E S S A N A L Y Z E R S D E D I C AT E D R E A G E N T S P U R E R A N D O M A C C E S S Miura One Miura 200 Miura 120 photometric tests per hour, up to 180 tests per hour

More information

Table of Contents. Introduction. Executive Summary. Rationale for Testing Decentralization

Table of Contents. Introduction. Executive Summary. Rationale for Testing Decentralization 2013 Analysis of the Point-of-Care Clinical Chemistry Market: US, Germany, Spain Physician Offices, Emergency Rooms, Operating/Recovery Suites, ICUs/CCUs, Cancer Clinics, Ambulatory Care Centers, Surgery

More information

CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE

CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE Croatian Centre for Quality Assessment in Laboratory Medicine Boskoviceva 18, 10000 Zagreb Croatia Tel/Phone & Fax: +385 1 48 28 133 E-mail:

More information

Proficiency Testing Evaluation

Proficiency Testing Evaluation Facility/Contact Phone: GENC GAMA HASTANESI LABORATUVARI / Fax: GENC GAMA HASTANESI LABORATUVARI Email (primary): Email (secondary): (Please add pt@aafp.org to your electronic address book) ATATURK MAH.

More information

SEQC EXTERNAL QUALITY ASSURANCE PROGRAMS

SEQC EXTERNAL QUALITY ASSURANCE PROGRAMS SPANISH SOCIETY OF CLINICAL BIOCHEMISTRY AND MOLECULAR PATHOLOGY SEQC EXTERNAL QUALITY ASSURANCE PROGRAMS Commutable Serum with Reference Values (SCR) Impact on standardization Beatriz Boned (1) / Emma

More information

HumaStar 600. So easy to handle. CoreLab DX. Random-Access Clinical Chemistry System

HumaStar 600. So easy to handle. CoreLab DX. Random-Access Clinical Chemistry System CoreLab DX HumaStar 600 Random-Access Clinical Chemistry System So easy to handle > High throughput > Reliable performance > Workflow-optimized handling Clinical Clinical Chemistry Chemistry Movie Clinical

More information

I.S.E. S.r.l Clinical Chemistry Solutions

I.S.E. S.r.l Clinical Chemistry Solutions Fully-automated Clinical Chemistry Analyzers up to 180 tests/hour I.S.E. S.r.l Clinical Chemistry Solutions CUSTOMIZED SOLUTIONS FOR YOUR LAB check our website at www.logotech-ise.com for news and updates

More information

ACID PHOSPHATASE (ACP) Continuous-spectrophotometric SFBC

ACID PHOSPHATASE (ACP) Continuous-spectrophotometric SFBC Acid phosphatase (ACP) catalyzes in acid medium the hydrolysis of the phosphate group from α-naphtyl phosphate. The α-naphtol formed reacts with a diazonium salt (Fast Red TR) originating a chromogen.

More information

Providing Vital Solutions for Your Laboratory

Providing Vital Solutions for Your Laboratory Test Menu General Chemistry Assays Albumin Bilirubin, Direct Bilirubin, Total Calcium Creatinine Glucose Iron, Total Magnesium Phosphorus Protein, Total Urea Nitrogen (BUN) Uric Acid Enzyme Assays Alanine

More information

Statistical validation of reagent lot change in the clinical chemistry laboratory can confer insights on good clinical laboratory practice

Statistical validation of reagent lot change in the clinical chemistry laboratory can confer insights on good clinical laboratory practice Original Article Annals of Clinical Biochemistry 2014, Vol. 51(6) 688 694! The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalspermissions.nav DOI: 10.1177/0004563214520749 acb.sagepub.com

More information

The Clinical Chemistry System that offers more so you do less!

The Clinical Chemistry System that offers more so you do less! The Clinical Chemistry System that offers more so you do less! A unique level of automation in a compact system Safe and flexible sample management Fully automatic cuvette management Cuvette management

More information

Tony Badrick and Graham Jones (RCPAQAP)

Tony Badrick and Graham Jones (RCPAQAP) Session 3: Traceability in external quality assessment. Why traceability is important to EQA providers? Tony Badrick and Graham Jones (RCPAQAP) EQA the more you look the more you see! Sturgeon C. Best

More information

Providing Vital Solutions for Your Laboratory

Providing Vital Solutions for Your Laboratory Test Menu General Chemistry Assays Albumin Bilirubin, Direct Bilirubin, Total Calcium Creatinine Glucose Iron, Total Magnesium Phosphorus Protein, Total Urea Nitrogen (BUN) Uric Acid Enzyme Assays Alanine

More information

VALID ONLY FOR C AND SC(ASCP) AND C AND SC(ASCP i ) TESTING DATES UP TO AND INCLUDING JUNE 30, 2019

VALID ONLY FOR C AND SC(ASCP) AND C AND SC(ASCP i ) TESTING DATES UP TO AND INCLUDING JUNE 30, 2019 TECHNOLOGIST AND INTERNATIONAL TECHNOLOGIST IN CHEMISTRY, C(ASCP) AND C(ASCP i ) SPECIALIST AND INTERNATIONAL SPECIALIST IN CHEMISTRY, SC(ASCP) AND SC(ASCP i ) EXAMINATION CONTENT GUIDELINE EXAMINATION

More information

BS-330E Chemistry Analyzer

BS-330E Chemistry Analyzer BS-330E Chemistry Analyzer BS-330E Chemistry Analyzer Intelligent collision protection Vertical & horizontal collision Audible alarm Ensure operator safety Smart, Versat Smart probe function Effective

More information

Positive patient identification Reagent barcode scanning Primary tubes STAT handling Reagent level sensing Test incompatibility

Positive patient identification Reagent barcode scanning Primary tubes STAT handling Reagent level sensing Test incompatibility Performance. Value. The Selectra XL delivers what your laboratory needs - an economical solution for your chemistry testing that doesn t sacrifi ce performance and reliability. The Selectra XL is built

More information

COMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis.

COMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis. L A B O R A T O R Y Clinical chemistry analyzers and reagents for laboratories needs. BIOCHEMICAL SYSTEMS INTERNATIONAL, as a diagnostic device manufacturer, has been researching for 25 years, with the

More information

S-UV (Sentinel Universal Vials) Reagents 6 Calibrators 16 Controls 17

S-UV (Sentinel Universal Vials) Reagents 6 Calibrators 16 Controls 17 LAB CATALOGUE The mission of Sentinel Diagnostics is the constant commitment to the research and development of innovative in-vitro diagnostics medical devices aimed at rendering clinical diagnostics more

More information

S-UV (Sentinel Universal Vials) Reagents 6 Calibrators 16 Controls 17

S-UV (Sentinel Universal Vials) Reagents 6 Calibrators 16 Controls 17 LAB CATALOGUE The mission of Sentinel Diagnostics is the constant commitment to the research and development of innovative in-vitro diagnostics medical devices aimed at rendering clinical diagnostics more

More information

Statistical Report: Quantitative Urine Clinical Chemistry Mail out date: October 26, 2015

Statistical Report: Quantitative Urine Clinical Chemistry Mail out date: October 26, 2015 ANDREW M. CUOMO Governor HOWARD A. ZUCKER, M.D., J.D. Commissioner SALLY DRESLIN, M.S., R.N. Executive Deputy Commissioner Statistical Report: Quantitative Urine Clinical Chemistry Mail out date: October

More information

Calibrators 16 Controls 17. Rheumatology (Latex Turbidimetry) 24 Other Proteins (Latex Turbidimetry) 25 Calibrators 27 Controls 29

Calibrators 16 Controls 17. Rheumatology (Latex Turbidimetry) 24 Other Proteins (Latex Turbidimetry) 25 Calibrators 27 Controls 29 LAB CATALOGUE The mission of Sentinel Diagnostics is the constant commitment to the research and development of innovative in-vitro diagnostics medical devices aimed at rendering clinical diagnostics more

More information

Clinical Chemistry and Immunodiagnostics Markets

Clinical Chemistry and Immunodiagnostics Markets MEDICAL DEVICES PHARMACEUTICALS CHEMICALS FOOD & BEVERAGE ELECTRONICS Clinical Chemistry and Immunodiagnostics Markets NEW PRODUCT DEVELOPMENT OPPORTUNITES AND BUSINESS EXPANSION STRATEGIES FOR INSTRUMENT

More information

An Evaluation of the Roche Cobas c 111

An Evaluation of the Roche Cobas c 111 An Evaluation of the Roche Cobas c 111 James L. Bowling, PhD, DABCC, Alex Katayev, MD (Laboratory Corporation of America, Department of Science and Technology, Elon, NC) DOI: 10.1309/LM6T8D1LKQXVNCAC Submitted

More information

BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE)

BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE) PRODUCT LIST 01 02 03 04 05 BLOOD GAS ELECTROLYTE (ISE) CHEMISTRY (ISE) QUALITY CONTROLS ELECTRODES Our Company Phoenix Diagnostics is a premier alternative manufacturer of consumables for Blood Gas, Electrolyte,

More information

Bench-top system for Immunoassay & Clinical Chemistry

Bench-top system for Immunoassay & Clinical Chemistry Bench-top system for Immunoassay & Clinical Chemistry Eclectica is a hybrid analyzer addressing the growing need for consolidation of automation platforms in clinical labs. Eclectica. which derives from

More information

Hycel. Hangelsgesellschaft m.b.h. - Catalog -

Hycel. Hangelsgesellschaft m.b.h. - Catalog - Hycel Hangelsgesellschaft m.b.h. - Catalog - TABLE OF CONTENTS HEMATOLOGY > HYCOUNT 3 > Reagents for Hycel hematology analyzers > Generic Reagents CLINICAL CHEMISTRY > HY-SAC > HYCHEM > HYCHEM 200 > HYCHEM

More information

LETTER TO THE EDITOR: UNLIKELINESS LIMITS ESTIMATION

LETTER TO THE EDITOR: UNLIKELINESS LIMITS ESTIMATION Gemma Solé Enrech, Xavier Fuentes Arderiu Letter to the Editor: Unlikeliness limits estimation LETTER TO THE EDITOR: UNLIKELINESS LIMITS ESTIMATION Gemma Solé Enrech, Xavier Fuentes Arderiu Laboratory

More information

UNIT: Basic Designs in Automation

UNIT: Basic Designs in Automation UNIT: Basic Designs in Automation 6basic.wpd Instrumentation IV Task To introduce basic designs and procedures in automation. Objectives Upon completion of this exercise, the student will: 1. Discuss common

More information

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - August 2015 (Event 15-3)

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - August 2015 (Event 15-3) ANDREW M. CUOMO Governor HOWARD A. ZUCKER, M.D., J.D. Commissioner SALLY DRESLIN, M.S., R.N. Executive Deputy Commissioner Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program

More information

CME/SAM. An Examination of the Usefulness of Repeat Testing Practices in a Large Hospital Clinical Chemistry Laboratory

CME/SAM. An Examination of the Usefulness of Repeat Testing Practices in a Large Hospital Clinical Chemistry Laboratory Clinical Chemistry / Repeat Testing Practices in Clinical Chemistry An Examination of the Usefulness of Repeat Testing Practices in a Large Hospital Clinical Chemistry Laboratory Carl O. Deetz, MD, PhD,

More information

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - August 2016 (Event 16-3)

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - August 2016 (Event 16-3) ANDREW M. CUOMO Governor HOWARD A. ZUCKER, M.D., J.D. Commissioner SALLY DRESLIN, M.S., R.N. Executive Deputy Commissioner Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program

More information

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - May 2016 (Event 16-2)

Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program. Statistical Summary - May 2016 (Event 16-2) ANDREW M. CUOMO Governor HOWARD A. ZUCKER, M.D., J.D. Commissioner SALLY DRESLIN, M.S., R.N. Executive Deputy Commissioner Therapeutic Substance Monitoring/Quantitative Toxicology Proficiency Test Program

More information

Verification of out-of-control situations detected by "average of normal" approach.

Verification of out-of-control situations detected by average of normal approach. Bond University epublications@bond Faculty of Health Sciences & Medicine Publications Faculty of Health Sciences & Medicine 11-1-2016 Verification of out-of-control situations detected by "average of normal"

More information

Review of Activities. Graham Jones. RCPAQAP Chemical Pathology

Review of Activities. Graham Jones. RCPAQAP Chemical Pathology RCPAQAP Chemical Pathology Review of Activities Graham Jones Chair 2013 in Focus 2013 New Programs/Analytes Programs Liquid Serum Chemistry Reference Interval Survey PoCT Chemistry (formerly Near Patient

More information

Science. Reagent Carryover Studies: Preventing Analytical Error with Open Clinical Chemistry Systems

Science. Reagent Carryover Studies: Preventing Analytical Error with Open Clinical Chemistry Systems Reagent Carryover Studies: Preventing Analytical Error with Open Clinical Chemistry Systems Joseph Boneno, MS, SC(ASCP), 1 Michelle Fokakis, MT(ASCP), 2 Dave Armbruster, PhD, DABCC, FACB, C(ASCP) 3 ( 1

More information

Potassium Enzymatic Assay Kit (Liquid Stable) Catalog Number: BQ 010-EAEL

Potassium Enzymatic Assay Kit (Liquid Stable) Catalog Number: BQ 010-EAEL Note: Serum specimens and all materials coming in contact with them should be handled and disposed as if capable of transmitting infection. Avoid contact with skin by wearing gloves and proper laboratory

More information

epoc Blood Analysis System: Summary of Analytical Methods and Performance

epoc Blood Analysis System: Summary of Analytical Methods and Performance White Paper epoc Blood Analysis System epoc Blood Analysis System: Summary of Analytical Methods and Performance siemens.com/poc White Paper epoc Blood Analysis System epoc Blood Analysis System White

More information

TURBIDIMETRY & NEPHELOMETRY. Mohsin Al-Saleh, Senior Biomedical Scientist (BSc. MLS-2004/MSc Clini. Chem. 2013) ID#6837

TURBIDIMETRY & NEPHELOMETRY. Mohsin Al-Saleh, Senior Biomedical Scientist (BSc. MLS-2004/MSc Clini. Chem. 2013) ID#6837 TURBIDIMETRY & NEPHELOMETRY Mohsin Al-Saleh, Senior Biomedical Scientist (BSc. MLS-2004/MSc Clini. Chem. 2013) ID#6837 Lecture Objectives: Introduction (An Overview about laboratory techniques) Definition

More information

Introduction and. Properties of Enzymes

Introduction and. Properties of Enzymes Unit-III Enzymes Contents 1. Introduction and Properties of enzymes 2. Nomenclature and Classification 3. Mechanism of enzyme-catalyzed reactions 4. Kinetics of enzyme-catalyzed reactions 5. Inhibition

More information

Cu-Creatinine- Metol system

Cu-Creatinine- Metol system Quantification of Creatinine in Human Serum using Metol as a Chromogenic Probe Materials and methods 6.1. Reagents 6.1.1. N-methyl-p-aminophenol sulfate N-methyl-p-aminophenol sulfate also denoted as Metol

More information

Enzymatic Assay of CALCINEURIN

Enzymatic Assay of CALCINEURIN PRINCIPLE: The assay for Calcineurin is based on its ability to bind to Calmodulin. Calmodulin which is bound to Calcineurin is no longer available to activate Phosphodiesterase 3':5'-Cyclic Nucleotide.

More information

SHEIKH ZAYED MEDICAL COLLEGE/HOSPTIAL, RAHIM YAR KHAN.

SHEIKH ZAYED MEDICAL COLLEGE/HOSPTIAL, RAHIM YAR KHAN. Page 1 of 15 PART-III SHEIKH ZAYED MEDICAL COLLEGE/HOSPTIAL, RAHIM YAR KHAN. Estimated Chemial Pathology: Tender List for the Bulk Purchase of Laboratory Kits, Chemicals & Reagents, Financial Year 2012-13.

More information

CEDIA OPIATE OFT ASSAY APPLICATION (UK) - Beckman Coulter AU680

CEDIA OPIATE OFT ASSAY APPLICATION (UK) - Beckman Coulter AU680 Microgenics Corporation Part of Thermo Fisher Scientific CEDIA OPIATE OFT ASSAY APPLICATION (UK) - Beckman Coulter AU680 Catalog No. 10010612, 10010659 The Thermo Scientific CEDIA Opiate OFT Assay is intended

More information

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology Spectrophotometry Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology Content Introduction Beer-Lambert law Instrument Applications Introduction 3 Body fluids such as blood, csf and urine contain organic and

More information

guide [ tech ] Chemistry Analyzers Abbott Park, Ill (847) Brea, Calif (800)

guide [ tech ] Chemistry Analyzers Abbott Park, Ill (847) Brea, Calif (800) Chemistry Analyzers Abbott Beckman Coulter Beckman Coulter Abbott Park, Ill (847) 937-6100 www.abbottdiagnositcs.com Name of product Abbott ARCHITECT immunochemistry analyzers AU480 AU680 1) What does

More information

Evaluation of the Olympus Demand random

Evaluation of the Olympus Demand random Automatic Chemistry of Clinical Laboratory Automation, Vol. 9, No. 3 (July-September 1987), pp. 113-118 Evaluation of the Olympus Demand random access chemistry analyser Susan B. Schotters, James H. McBride,

More information

+ 1 (508) High Technology, Inc. Overview Content Equipment, reagents and accessories for clinical laboratories

+ 1 (508) High Technology, Inc. Overview Content Equipment, reagents and accessories for clinical laboratories Overview Content HTI Diagnostics is the manufacturing division of High Technology, Inc. with its headquarters located in Massachusetts, USA. Equipment, reagents and accessories for clinical laboratories

More information

Fully-automated Clinical Chemistry Analysers Catalogue of Products.

Fully-automated Clinical Chemistry Analysers Catalogue of Products. Fully-automated Clinical Chemistry Analysers Cataloue of Products www.lootech-ise.com check our website at www.lootech-ise.com for news and updates Company Contacts Name Function Office Phone Fax Number

More information

MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory

MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory Journal of Automated Methods & Management in Chemistry, (), no., 8 c MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory Gary L. Horowitz, Zahur Zaman, NorbertJ.C.Blanckaert, Daniel

More information

Alkaline Phosphatase Colorimetric Assay Kit

Alkaline Phosphatase Colorimetric Assay Kit Alkaline Phosphatase Colorimetric Assay Kit Catalog No. KM0018 Detection and Quantification of Alkaline Phosphatase Concentrations in Biological Samples. Research Purposes Only. Not Intended for Diagnostic

More information

Analytical. Chemiluminescence Immunoassay (CLIA) System. Bio Med. Analytical Technologies Limited.

Analytical. Chemiluminescence Immunoassay (CLIA) System. Bio Med. Analytical Technologies Limited. ISO 9001 Analytical Bio Med Chemiluminescence Immunoassay (CLIA) System Analytical Technologies Limited www.analyticalgroup.net OUTSTANDING TECHNOLOGY Chemiluminescence Immunoassay (CLIA) System CLIA uses

More information

HIGH INC rfechnology LABORATORY EQUIPMENT, REAGENTS AND ACCESSORIES. Catalogs, Videos, and Brochures available at:

HIGH INC rfechnology LABORATORY EQUIPMENT, REAGENTS AND ACCESSORIES. Catalogs, Videos, and Brochures available at: - HIGH INC rfechnology LABORATORY EQUIPMENT, REAGENTS AND ACCESSORIES Catalog 2018 Catalogs, Videos, and Brochures available at: Overview Content HTI Diagnostics is the manufacturing division of High Technology,

More information

AS 117. Traceability to the primary standards at Radiometer. Author: Hans Bjarne Kristensen. January Contents

AS 117. Traceability to the primary standards at Radiometer. Author: Hans Bjarne Kristensen. January Contents AS 117 Author: Traceability to the primary standards at Radiometer Hans Bjarne Kristensen January 2006 The AS series of scientific and technical articles from Radiometer is named after Professor Poul Astrup,

More information

CEDIA COCAINE OFT ASSAY APPLICATION (UK) BECKMAN COULTER AU680

CEDIA COCAINE OFT ASSAY APPLICATION (UK) BECKMAN COULTER AU680 Microgenics Corporation Part of Thermo Fisher Scientific CEDIA COCAINE OFT ASSAY APPLICATION (UK) BECKMAN COULTER AU680 Catalog No. 10014734, 10014740 The Thermo Scientific CEDIA Cocaine OFT Assay is intended

More information

Enzymatic Assay of GLYCOGEN SYNTHASE (EC )

Enzymatic Assay of GLYCOGEN SYNTHASE (EC ) PRINCIPLE: UDPG + (Glycogen) n Glycogen Synthase > UDP + (Glycogen) n+1 UDP + PEP PK > UTP + Pyruvate Pyruvate + ß-NADH LDH > Lactate + ß-NAD Abbreviations: UDPG = Uridine 5'-Diphosphoglucose UDP = Uridine

More information

State of the Art for Measurement of Urine Albumin: Comparison of Routine. Measurement Procedures to Isotope Dilution Tandem Mass Spectrometry

State of the Art for Measurement of Urine Albumin: Comparison of Routine. Measurement Procedures to Isotope Dilution Tandem Mass Spectrometry 1 of 27 State of the Art for Measurement of Urine Albumin: Comparison of Routine Measurement Procedures to Isotope Dilution Tandem Mass Spectrometry Supplemental Information, Tables and Data 2 of 27 Supplemental

More information

Method of Enzyme Assay

Method of Enzyme Assay Method of Enzyme Assay Objective To study the different methods for determining enzyme activity. Use these method in diagnosis of certain diseases How to follow a reaction? Enzyme assays: Are laboratory

More information

Method of Enzyme Assay

Method of Enzyme Assay Method of Enzyme Assay Objective To study the different methods for determining enzyme activity. Enzyme assays: Are laboratory methods for measuring enzymatic activity. All enzyme assays measure either

More information

Diagnostic Equipments

Diagnostic Equipments Diagnostic Equipments Diagnostic Equipments FACA-200 Fully Automatic Chemistry Analyzer Labomed introduces an automatic chemistry analyzer with varying testing capacities. 200 tests/hour CABINET IS OPTIONAL

More information

Immunoassay, Clinical Chemistry and Specific Protein Calibration

Immunoassay, Clinical Chemistry and Specific Protein Calibration Immunoassay, Clinical Chemistry and Specific Protein Calibration 1 Definitions: Calibration curve: Is a plot of the Analytical Signals ( ex. Optical Density) against the concentration of the analyte (substance

More information

HumaStar 100 HumaStar 200

HumaStar 100 HumaStar 200 HumaStar 100 HumaStar 200 Key advantages Competition Product features Rev. 08d 07.09.2015 Scope of supply The slides provided in this section are concerned with availability, scope of supply and registration

More information

Summary of Analytical Methods and Performance The epoc Blood Analysis System. Data Compilation provided by Alere

Summary of Analytical Methods and Performance The epoc Blood Analysis System. Data Compilation provided by Alere Summary of Analytical Methods and Performance The epoc Blood Analysis System Data Compilation provided by Alere Table of Contents Page Introduction.... 4 Glossary... 5 Methodologies.... 6 ph.... 8 pco

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: Station Road Keith anffshire 55 5U Chivas

More information

HANDBOOK OF DRUG ANALYSIS

HANDBOOK OF DRUG ANALYSIS HANDBOOK OF DRUG ANALYSIS APPLICATIONS IN FORENSIC AND CLINICAL LABORATORIES Ray H. Liu Daniel E. Gadzala American Chemical Society Washington, DC Contents Dedication Foreword Preface About the Authors

More information

Technical Guide 4 A Guide on Measurement Uncertainty in Medical Testing

Technical Guide 4 A Guide on Measurement Uncertainty in Medical Testing ACCREDITATION SCHEME FOR LABORATORIES Technical Guide 4 A Guide on Measurement Uncertainty in Medical Testing Technical Guide 4, Feb 13 Technical Guide 4, First Edition, February 013 Page 1 of 51 The SAC

More information

ENZYMES. by: Dr. Hadi Mozafari

ENZYMES. by: Dr. Hadi Mozafari ENZYMES by: Dr. Hadi Mozafari 1 Specifications Often are Polymers Have a protein structures Enzymes are the biochemical reactions Katalyzers Enzymes are Simple & Complex compounds 2 Enzymatic Reactions

More information

Roles and responsibilities in verification of traceability of in vitro medical diagnostics (IVD)

Roles and responsibilities in verification of traceability of in vitro medical diagnostics (IVD) Roles and responsibilities in verification of traceability of in vitro medical diagnostics (IVD) Federica Braga University of Milan Medical School Centre for Metrological Traceability in Laboratory Medicine

More information

CL-1000i Chemiluminescence Immunoassay System

CL-1000i Chemiluminescence Immunoassay System CL-1000i Chemiluminescence Immunoassay System CL-1000i Chemiluminescence Immunoassay System Enhanced Reaction System 4-phase magnetic separation with precisely controlled temperature Consistent performance

More information

CEDIA COCAINE OFT ASSAY APPLICATION (EU) BECKMAN COULTER AU680

CEDIA COCAINE OFT ASSAY APPLICATION (EU) BECKMAN COULTER AU680 Microgenics Corporation Part of Thermo Fisher Scientific CEDIA COCAINE OFT ASSAY APPLICATION (EU) BECKMAN COULTER AU680 Catalog No. 10014734, 10014740 The Thermo Scientific CEDIA Cocaine OFT Assay is intended

More information

CEDIA CYCLOSPORINE PLUS (LOW RANGE) APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800

CEDIA CYCLOSPORINE PLUS (LOW RANGE) APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800 CEDIA CYCLOSPORINE PLUS (LOW RANGE) APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800 Beckman Coulter Reagent REF A31849 The CEDIA Cyclosporine PLUS assay is for the in vitro quantitative determination

More information

The reliable, compact & versatile immunoassay analyser

The reliable, compact & versatile immunoassay analyser Fully Automated Immunoassay System Eclectica TiCA, an immunoassay analyser addressing your needs for a compact and reliable fully automated platform. Eclectica TiCA is a newly designed state of the of

More information

Chemiluminescence Immunoassay System (CLIA) 3001

Chemiluminescence Immunoassay System (CLIA) 3001 Turnkey Laboratories Solutions Chemiluminescence Immunoassay System (CLIA) 3001 ISO 9001 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 215 Electronic Supplementary Information Redox cycling-amplified enzymatic Ag deposition

More information

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date AU US Instructions For Use 2017 Beckman Coulter, Inc. All rights reserved. FER Ferritin OSR61203 4 x 24 ml R1, 4 x 12 ml R2 For in vitro diagnostic use only. ANNUAL REVIEW For Rx use only Reviewed by Date

More information

Enzymatic Assay of HYPOXANTHINE-GUANINE PHOSPHORIBOSYL TRANSFERASE (EC )

Enzymatic Assay of HYPOXANTHINE-GUANINE PHOSPHORIBOSYL TRANSFERASE (EC ) PRINCIPLE: PRPP + Guanine HGPRT > GMP + Pyrophosphate Mg ++ GMP + ATP GK > GDP + ADP ADP + PEP PK > ATP + Pyruvate GDP + PEP PK > GTP + Pyruvate 2 Pyruvate + 2 ß-NADH LDH > 2 Lactate + 2 ß-NAD Abbreviations

More information

IgE Immunoglobulins Additional Information ITSL Turbidimetric Kit REF.: K.ITSL.IGE

IgE Immunoglobulins Additional Information ITSL Turbidimetric Kit REF.: K.ITSL.IGE NEW SCIENTIFIC COMPANY España, S.r.l. Valencia, 558 - ES08026 Barcelona tel.: +34 93 244 82 94 fax: +34 93 244 82 95 IgE Immunoglobulins Additional Information ITSL Turbidimetric Kit REF.: K.ITSL.IGE PRODUCT

More information

Enzymatic Assay of GALACTOSYLTRANSFERASE (EC )

Enzymatic Assay of GALACTOSYLTRANSFERASE (EC ) Enzymatic Assay of GALACTOSYLTRANSFERASE PRINCIPLE: UDP-Galactose + D-Glucose Galactosyltransferase > UDP + Lactose UDP + PEP PK > Pyruvate + UTP Pyruvate + ß-NADH LDH > Lactate + ß-NAD Abbreviations used:

More information

Protein Quantitation using a UV-visible Spectrophotometer

Protein Quantitation using a UV-visible Spectrophotometer UV-0003 UV-visible Spectrophotometer Introduction Generally, protein quantitation can be made using a simple UV-Visible spectrophotometer. The V-630 Bio (Figure 1) is a UV- Visible spectrophotometer designed

More information

PRINCIPLE. Kit Reorder # Kit Reorder # Kit Reorder # A17652 Kit Reorder # A ANNUAL REVIEW Reviewed by: Date.

PRINCIPLE. Kit Reorder # Kit Reorder # Kit Reorder # A17652 Kit Reorder # A ANNUAL REVIEW Reviewed by: Date. SYNCHRON CX 3 DELTA System Chemistry Information Sheet Copyright 2007 Beckman Coulter, Inc. For In Vitro Diagnostic Use Chloride Kit Reorder # 450214 Kit Reorder # 472095 Kit Reorder # A17652 Kit Reorder

More information

Uncertainty sources of reference measurement procedures for enzymes

Uncertainty sources of reference measurement procedures for enzymes Medical School Hannover Institute for Clinical Chemistry Director: Prof. Dr. K. Brand Uncertainty sources of reference measurement procedures for enzymes R. Klauke and G. Schumann Renate Strache Rainer

More information

Preface... (v) Acknowledgement... (vii) Introduction Chapter 1 Acids and Bases... 21

Preface... (v) Acknowledgement... (vii) Introduction Chapter 1 Acids and Bases... 21 CONTENTS Preface... (v) Acknowledgement... (vii) Introduction... 1 Chapter 1 Acids and Bases... 21 Experiment 1.1 To Prepare 1M HCl and Standardize it and Perform Assay of Sodium Hydrogen Carbonate...

More information

Gentian Canine CRP Immunoassay Application Note for ABX Pentra * 400

Gentian Canine CRP Immunoassay Application Note for ABX Pentra * 400 v02-jan2014 Gentian Canine CRP Immunoassay Application Note for ABX Pentra * 400 Intended Use The canine CRP immunoassay on Horiba Medical's ABX Pentra 400 is an in vitro diagnostic test for quantitative

More information

Evaluation of Survey results for regulatory grading

Evaluation of Survey results for regulatory grading Important information regarding grading of specimen C -02 Specim en C-02 w as a carefully prepared fresh frozen hum an serum sam ple that w as sent to all participants in the Survey. Your laboratory s

More information

SAMPLE. ELITech Group - Product Pipeline Analysis, 2015 Update. Reference Code: GDME51138PD. Publication Date: June Page 1

SAMPLE. ELITech Group - Product Pipeline Analysis, 2015 Update. Reference Code: GDME51138PD. Publication Date: June Page 1 Publication Date: June 2015 Page 1 Table of Contents Table of Contents... 2 List of Tables... 5 List of Figures... 8 ELITech Group Company Snapshot... 9 ELITech Group Company Overview... 9 Key Information...

More information

New York State Department of Health Wadsworth Center Blood ph and Gas/Chemistry Educational Proficiency Testing February 7, 2011

New York State Department of Health Wadsworth Center Blood ph and Gas/Chemistry Educational Proficiency Testing February 7, 2011 New York State Department of Health Wadsworth Center Blood ph and Gas/Chemistry Educational Proficiency Testing February 7, 2011 Glucose (mg/dl) 87.7 ± 3.63 160.2 ± 4.78 230.5 ± 7.04 266.0 ± 8.81 52.5

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Parkside Lane Dewsbury Road Leeds LS11 5SX Contact: Mr K Walker Tel: +44 (0)113 385 9157 Fax: +44 (0)113 276 0472 E-Mail: Kevin.Walker@soil-engineering.co.uk

More information

1 Introduction 1 STA. High performance liquid chromatography (HPLC) Basic and acidic extract (plasma) Automated screening system, Bio-Rad (urine)

1 Introduction 1 STA. High performance liquid chromatography (HPLC) Basic and acidic extract (plasma) Automated screening system, Bio-Rad (urine) 1 Introduction 1 1 Introduction 1.1 Systematic Toxicological Analysis Acute intoxication represents an emergency case. Fast and reliable diagnosis is very important for the prognosis and further treatment.

More information

Quantitative Determination of Proteins

Quantitative Determination of Proteins Application Note UV-0003-E Quantitative Determination of Proteins Generally, the concentration of proteins is measured using UV-Vis spectrophotometers. The JASCO V-630 Bio (Figure 1) is a UV/Vis spectrophotometer

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE INSTRUCTIONS FOR USE VITROS Chemistry Products RF Reagent RF 680 1729 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry Products RF Reagent is used on the VITROS 5,1 FS Chemistry

More information

Alkaline Phosphatase Labeling Kit-NH2

Alkaline Phosphatase Labeling Kit-NH2 Alkaline Phosphatase Labeling Kit-NH2 Catalog Number KA0001 1 Kit Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay...

More information

NAD/NADH Microplate Assay Kit User Manual

NAD/NADH Microplate Assay Kit User Manual NAD/NADH Microplate Assay Kit User Manual Catalog # CAK1008 Detection and Quantification of NAD/NADH Content in Urine, Serum, Plasma, Tissue extracts, Cell lysate, Cell culture media and Other biological

More information

Reference Systems in Clinical Enzymology

Reference Systems in Clinical Enzymology Reference Systems in Clinical Enzymology Lothar Siekmann Department of Clinical Biochemistry, University of Bonn, Germany At the IFCC General Conference in Sevilla, Spain (March 1998) it was decided to

More information

Fully Automated Random Access Chemistry Analyser!

Fully Automated Random Access Chemistry Analyser! Fully Automated Random Access Chemistry Analyser! Sapphire 800 is a powerful and Intelligent Chemistry Analyser recently launched by Audit Diagnostics. The higher throughput of 800 tests/hour is designed

More information

Bioreactor Engineering Laboratory

Bioreactor Engineering Laboratory Bioreactor Engineering Laboratory Determination of kinetics parameters of enzymatic hydrolysis of lactose catalyzed by β-galactosidase. Supervisor: Karolina Labus, PhD 1. THEROETICAL PART Enzymes are macromolecular,

More information

TaKaRa BCA Protein Assay Kit

TaKaRa BCA Protein Assay Kit Cat. # T9300A For Research Use TaKaRa BCA Protein Assay Kit Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required by not Provided... 3 V. Precautions

More information

CX4, CX5, CX7, CX9 PRO

CX4, CX5, CX7, CX9 PRO Beckman CX3, CX4CE, CX5CE, CX7, Synchron Beckman CX3, CX4, CX5, CX7 Delta, CX9 ALX Beckman CX3, CX4, CX5, CX7, CX9 PRO BK-A17652D A17652 Electrolyte Buffer Reagent 4.7 CX 3,5,7,9 2x2000mL BK-A17657D A17657

More information