1 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february Coded Pulse Excitation for Ultrasonic Strain Imaging Jie Liu and Michael F. Insana, Member, IEEE Abstract Decorrelation strain noise can be significantly reduced in low echo-signal-to-noise (esnr) conditions using coded excitation. Large time-bandwidth-product (>30) pulses are transmitted into tissue mimicking phantoms with 2.5-mm diameter inclusions that mimic the elastic properties of breast lesions. We observed a 5 10 db improvement in esnr that led to a doubling of the depth of focus for strain images with no reduction of spatial resolution. In high esnr conditions, coded excitation permits the use of higher carrier frequencies and shorter correlation windows to improve the attainable spatial resolution for strain relative to that obtained with conventional short pulses. This paper summarizes comparative studies of strain imaging in noiselimited conditions obtained by short pulses and four common aperiodic codes (chirp, Barker, suboptimal, and Golay) as a function of attenuation, esnr and applied strain. Imaging performance is quantified using SNR for displacement (SNR d ), local modulation transfer function (LMTF), and contrast-to-noise ratio for strain (CNR). We found that chirp and Golay codes are the most robust for imaging soft tissue deformation using matched filter decoding. Their superior performance is obtained by balancing the need for low-range lobes, large esnr improvement, and short-code duration. I. Introduction There is considerable recent interest in the use of compressible transmission codes for medical ultrasonic imaging. Under low echo-signal-to-noise-ratio (esnr) conditions, temporally coded excitation pulses provide distinct advantages. For example, they have been shown to improve esnr in vascular imaging with intravascular ultrasound (IVUS) arrays [1], in bone attenuation estimates [2], in bubble-preserving, nonlinear contrast imaging [3], in three-dimensional (3-D) imaging using parallel acquisition [4], and in very high frame rate 2-D acquisitions when combined with spatial encoding [5]. Coded excitation provides greater penetration by increasing the average power delivered to tissues without increasing peak power [6] [8]. Our application is elasticity imaging. Specifically, the interest is strain estimation for breast cancer detection in which the visibility of small lesions is limited primarily by decorrelation noise. Low esnr reduces the coherence between sequential echo frames acquired for correlationbased displacement estimates [9]. As a result large dis- Manuscript received January 28, 2004; accepted June 25, This work was supported in part by NIH R01 CA82497 and Siemens Medical Solutions, Inc. USA, Ultrasound Division. The authors are with the Department of Biomedical Engineering, University of California Davis, Davis, CA ( jieliu@ucdavis.edu). placement errors are generated that appear in strain images as a high-intensity noise known as decorrelation noise. In this situation, longer correlation window lengths reduce decorrelation noise for small tissue deformations at the cost of slightly reduced axial resolution. Here we explore applications of coded pulse excitation methods to strain estimation in low esnr conditions (<40 db). The same methods may be applied in high esnr situations to improve spatial resolution by allowing the use of higher carrier frequencies. Coded excitation involves the transmission of longduration pressure pulses with a time-bandwidth product (TBP) greater than 1. By coding the pulse on transmission, the received echo signals may be processed to compress (decode) the effective impulse response, and thus restore spatial resolution. If decoding is successful, esnr is amplified by a factor equal to the TBP without compromising contrast or spatial resolution. If decoding is incomplete, the acoustic energy remains partially distributed spatially, producing range lobes that reduce B-mode image contrast. In strain imaging, range lobes increase decorrelation noise, particularly in high strain-contrast regions [10], thus negating the advantages of coded excitation. We have applied coded excitation methods to simulated and experimental phantom echo data to find which codes and associated parameters improve the quality of strain estimates. O Donnell [6] found that db improvements in esnr are possible for typical B-mode imaging situations. The factors that must be considered when applying coded pulse excitation to B-mode imaging include esnr, frequency-dependent absorption, clutter from range lobes, axial resolution, and frame rate (multipulse codes). In addition, we must add the effects of code distortion caused by the physical deformation of the scattering medium to consider applications in strain imaging. The goal is to translate improvements in esnr into improvements in displacement and strain SNR while retaining acceptable levels of strain image contrast and spatial resolution. II. Methods Each step in the formation of a strain image is discussed below, from coded-pulse transmission through strain estimation. The entire process is summarized in Fig. 1. Strain is estimated by comparing echo frames recorded before and after a deformation. The nth echo sample g j [n] recorded in frame j arises from a one-dimensional (1-D) /$20.00 c 2005 IEEE

2 232 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february 2005 TABLE I Binary PM Codes Used in This Paper. Code Length (bit) Hexadecimal Barker 7 72 Barker 13 00CA Suboptimal 32 FA6D48C7 Golay 8 12; 1D Golay D12E2; 121DED1D Fig. 1. Strain estimator using PM and FM coded pulse transmission. Conventional pulse-echo methods are obtained by setting v[n] = δ[n]. random scattering function f j (x) through the continuousto-discrete integral transformation: g j[n] = dx h(nt, x)f j (x)+e j[n], (1) where e j [n] is a sample of the signal independent noise vector and h(nt, x) is the shift-varying impulse response of the system. Time t = nt is sampled on the interval T with integer n. Arguments in brackets (parentheses) indicate functions of discrete (continuous) variables; f and e are wide-sense stationary (WSS) random processes. A. System Impulse Response 1. Binary PM sequences: h(nt, x) for a phasemodulated (PM) sequence has three components. First, a code of length K bits is selected for properties related to orthogonality (matched filter decoding) or low noise amplification (inverse filter decoding) [11]. For example, a K = 13-bit Barker code can be written as the hexadecimal number 00CA. Converting to binary and then remapping 1 1and0 +1, the code sequence is c[k]=[ ]. It is expanded in time by the factor L to match the RF sampling rate using the expression [12]: c[n] = k= c[k]δ[n kl], where δ[n] is a Kronecker delta. Codes included in this study are listed in Table I. The second component is an L-bit base sequence b[n] [8]. Its convolution with c gives the transducer excitation voltage waveform for PM codes: v PM [n] = k= b[n k]c[k] = {b c}[n]. The form of the base sequence and its length determine the center frequency and bandwidth of v PM.Forexample, our experimental conditions include f 0 =10MHz transducer resonant frequency, f/f 0 =0.6relative bandwidth, and f s = 40 Msample/s sampling rate (T =25ns). The integer expansion factor is L = f s / f =7andthe base sequence is b[n] =[ ]. The period of the base-sequence square wave is 4T = 1/f 0 = 0.1 µs. Also, it contains roughly three half cycles of the square wave, so the bandwidth is 57%. Although the duration of coded excitation voltage waveforms can be 5.58 µs (typical for K = 32-bit), the bandwidth is broad and consequently these pulses have large time-bandwidth products, TBP = K. The third component is the pulse-echo impulse response of the ultrasonic system h s (nt, x), a function of space and time. The net impulse response is a convolution between the voltage waveform and the system impulse response: h(nt, x) = m= v PM [n m]h s (mt, x) = {b c h s }(nt, x). All three components of the linear system are assumed to be time invariant. 2. FM bursts: h(nt, x) for a linear frequencymodulated (FM chirp) bursts [13] can be represented by two components as illustrated in Fig. 1. The chirp voltage is: v FM [n] =w[n]exp ( i2π ( f 0 nt + α(nt ) 2)), (2) where α = f/t p is the frequency-ramp constant in MHz/µs; w[n] is a Tukey window function [14]: w[n] = ( ( )) cos π n Np/4(1+β) Np(1+β) N p/2(1 β) 4 n Np 2 N p,, 1 0 n Np 2 Np(1+β) 4 where T p = N p T is the pulse duration and β [0, 1], such that β = 0 is a rectangular window, and β =1isaHanning window. T p and β are selected to minimize range-lobe amplitudes ( 13 db when β = 0 [15]) without excessively broadening the main lobe. The ultrasonic system h s (nt, x) is the same as for the PM codes.

3 liu and insana: comparative studies of strain imaging 233 B. Echo Signals The jth coded echo frame g j [n] is the reference or precompression frame [see (1)], g j+1 [n] is the postcompression frame, and both are nonstationary random processes. We assume all tissue motion occurs between frame acquisitions. Echo frames can be coherent when the scattering functions for g j and g j+1 are related by a material description of continuum motion (one-to-one mapping of scatterers) [16]: f j+1 (x) =f j (x + d(x)), where d(x) describes spatially varying scatterer displacements resulting from an applied deformation force [17]. C. Pulse Compression Appropriate filtering of the received echo signals minimizes the correlation length of g j if the code sequence is well designed. We chose the matched filtering approach [13], whereby, for PM codes, g j are convolved with the matched filter c [ n] to produce a decoded echo signal g j having a TBP that is approximately one: g j [n] = ˆφ cg [n] = c [m n]g j [m] m= [ ] = φ cc [n l] dx h sb (lt, x)f j (x) + e j [n], (3) l= } where h sb [n] =(h s b)[n], φ xy = E {ˆφxy is the correlation function between sequences x and y, ande{ } is the expectation operator. e j [n] =ˆφ ce [n] isafilterednoise realization. A code sequence is optimal when the range lobes are the smallest possible [13]. For example, the PM Barker code is optimal because φ cc [n]/φ cc [0] 1/K for n 0. Unfortunately, the maximum Barker sequence is 13 bits. To achieve high esnr, longer, suboptimal codes suggested by others [11] also were examined. Optimal codes with long sequences approximate the result φ cc [n] Kδ[n], so that (3) reduces to: g j [n] K dx h sb (nt, x)f j (x)+e j [n] = s j [n]+e j [n]. (4) For Golay codes, K 2K. Scatterer motion, attenuation, and other common phenomena distort echo signals and thus increase range lobes often with little effect on the main lobe. In these situations, (3) rather than (4) more accurately represents the filtered echo frames g j and g j+1. Although (3) and (4) apply to PM codes, comparable results can be obtained for FM codes. D. Strain Estimator Decoded echo frames g j and g j+1 are segmented and cross correlated to estimate local displacements using methods described elsewhere [9]. Phantom data were companded in 2-D prior to 1-D cross correlation to minimize decorrelation. Companding was not applied while estimating displacements in 1-D echo simulations. And, longitudinal strain estimates ˆɛ[n] are computed from the spatial derivative of displacement along the direction of the beam axis. In practice, we apply a finite impulse response (FIR) differentiation filter h d [12] to displacement estimates ˆd[n] :ˆɛ[n] ={h d ˆd}[n]. E. Quality Metrics Coded excitation was adapted to strain imaging by selecting code parameters that optimized the quality metrics described below. 1. esnr: Pulse compressionimproves esnr by increasing the echo signal energy more than the noise energy. To quantify the change in esnr for our shift-varying system, we use (4) to find: ( ) φss [0,n] esnr[n] =10log φ ee [n] ( E{ K =10log dx h ) sb(nt, x)f j (x) 2 } E{ e[n] 2 } ( K 2 σ 2 ) (5) f =10log Kσe 2 dx h 2 sb (nt, x) =10logK +esnr [n], where σf 2 and σ2 e are the object and noise variances and esnr is the echo-signal-to-noise ratio for the conventional, short-duration pulse assuming no attenuation. The last form of (5) shows that esnr for coded excitation is nominally larger than esnr by the amount 10 log K = 10 log TBP. 2. LMTF: Local modulation transfer function (LMTF) is the normalized Fourier transform of the corresponding local impulse response (LIR). The LMTF is adopted to quantitatively evaluate the axial resolution of ultrasonic strain imaging. The base sequence b(t) was selected to match the transducer bandwidth in order to maximize the acoustic power given the applied electrical power. As a result, we maximized esnr at the cost of lengthening the compressed pulse, h sb [n] =(h s b)[n]. In B-mode imaging, longer pulses translate directly into a loss of axial resolution. However, in strain imaging, the effect on axial resolution is not as obvious. The correlation window and pulse lengths both factor into the determination of axial resolution. In noise-limited strain estimation, the correlation window is set several times longer than the axial pulse dimension to suppress the effects of echo noise. The increased esnr with coded excitation permit use of shorter

4 234 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february 2005 correlation windows, which could lead to comparable or superior axial resolution for strain despite a longer pulse length. To test these ideas, we simulated nonstationary echo signals that enabled measurement of the LIR for strain estimates. The LIR is the output of the strain estimator LIR(nT, x 0 ) = ˆɛ[n] for a strain impulse input, i.e., ɛ(x) δ(x x 0 ). Axial resolution for different pulses was compared using the normalized Fourier transform of the corresponding LIR LMTF via methods described previously [17]: LMTF x0 [k] = N n=1 E{ˆɛ (nt, x 0)} e i2πkn/n N n=1 E{ˆɛ (nt, x, 0)} (6) where N is the number of strain estimates in LIR. The shift variant system response means that LIR and LMTF vary with x SNR d : The SNR d estimates SNR d [18] is found by applying a known input displacement d(x)intoourestima- tor and measuring the output ˆd[n]. For uniaxial compression applied to a homogeneous medium along the sound beam axis, the input displacement increases linearly with range. The figure of merit: ( )) SNR d =10log ρ 2ˆdd / (1 ρ 2ˆdd, (7) where: ρ 2ˆdd = 1 N N n=1 φ 2ˆdd [0,n] φ dd [0,n]φ ˆd ˆd[0,n], reaches its maximum value of one when the input and estimates are identical; ˆd are computed from nonstationary echo data. Although the corresponding correlation coefficients can vary significantly with depth, the simple uniaxial deformation produced mean and variance measurements that did not vary significantly. Consequently, values were averaged as shown. The SNR d is an appropriate measure for results obtained from 1-D echo simulations. 4. CNR ɛ : To include effects that alter lesion contrast or any 2-D correlations that may exist among strain estimates, we adopted the contrast-to-noise ratio (CNR) to evaluate applications of coded excitation to strain images. Let ˆɛ t and ˆɛ b be the mean strains inside a lesion target and in the surrounding background, respectively. Also let var t and var b be the sample variances for the corresponding regions. Then: CNR ɛ = ˆɛ b ˆɛ t (varb +var t ) /2. (8) III. 1-D Simulations and Measurements A. Echo Simulations Object scatterers f j are simulated numerically in 1-D using Monte Carlo methods [17]. The h(nt, x) is modeled as a shift-varying pulse with center frequency 10 MHz, fractional bandwidth 0.6, and frequency-dependent attenuation. The pulse lengths of the short pulse, chirp with Tukey-window apodization, 32-bit Golay code, and 32-bit suboptimal code at 60% bandwidth are mm, 4.9 mm, 4.3 mm, and 4.3 mm, respectively. The total energy transmitted is the same for all coding sequences. Each data point presented is comprised of measurements from 100 independent echo waveform pairs. Each pair is individually processed to estimate displacement and strain then averaged. Two 1-D software phantoms were used to simulate echo signals from deformed media with different strain patterns. One provided a homogeneous strain along a 5-cm depth to study SNR d in the ranges of esnr =10to60dB, attenuation coefficient slope = 0.1 to 0.9 cm/db/mhz, and applied strain 0.1% to 1%. The esnr is measured at the focal length of the aperture with no medium attenuation. In situations in which the attenuation slope is 0.6 db/cm/mhz, esnr for our broadband system is reduced approximately 10 db. The second software phantom provides an impulse strain (step displacement). This phantom is used to investigate the effects of the net impulse response on axial resolution. B. Echo Simulation Results Fig. 2(a) shows SNR d for four different pulses as a function of esnr using the homogeneous software phantom. Other parameters are held constant. As expected, SNR d increases with esnr. Coded pulses provide the greatest improvement over the short pulse at low esnr.thechirp and Golay pulse performances are nearly equal. We fixed esnr at 40 db then studied the effects of increasing the slope of the frequency-dependent attenuation coefficient using the homogeneous software phantom. Results are summarized in Fig. 2(b). The SNR d values fall with increasing attenuation slope for all pulses, and the decline is much greater for the short pulse. Our simulation verified that coded pulse excitation (especially for chirp and Golay) significantly reduces strain noise in highly absorbing tissues. Fig. 3(a) shows SNR d for all pulses as a function of applied strain using the homogeneous phantom. Values were found to decrease with compressive strain. For small deformation, SNR d was greater for the chirp and Golay pulses than the short pulse. For deformations greater than 0.7%, SNR d for the chirp and Golay pulse are about 2 db less than the short pulse. As demonstrated in Figs. 2 and 3(a), chirp and Golay pulses have similar performances for SNR d, but the suboptimal coded pulse is consistently inferior.

5 liu and insana: comparative studies of strain imaging 235 Fig. 2. (a) SNR d for short pulse (dotted line), chirp pulse (solid line), 32-bit suboptimal code (dashdot line), and 32-bit Golay code (dashed line) are shown as a function of esnr. Attenuation coefficient slope is 0.6 db/cm/mhz. (b) SNR d for all pulses are shown as a function of attenuation coefficient slope. esnr is 40 db. The correlation window length was 1.23 mm, and the applied strain was 0.5% for all measurements. Fig. 3. (a) SNR d for all pulses are shown as a function of applied strain. The correlation window length is 0.62 mm. (b) SNR d for chirp pulse as a function of pulse length under applied strain 0.3%, 0.5%, and 0.7%, respectively. The correlation window length is 1.23 mm. The attenuation coefficient slope, 0.6 db/cm/mhz, and esnr,40db,arefixed. Longer coded pulses, for example, 3.85 mm for 0.5% applied strain, have greater esnr but their propagation through deformed media increases displacement noise because of the range lobes generated by incomplete pulse compression. Fig. 3(b) shows there is an optimal coded pulse length unique to the strain estimation conditions. Because the greatest relative improvements in SNR d for coded pulses occur at the smallest deformation, Fig. 3, it is reasonable to use multicompression methods [19]. Fig. 4 demonstrates SNR d for the chirp as a function of pulse length using both single compression (0.3% and 0.6% applied strains) and multicompression (2 0.3% strain) techniques. The SNR d for the 7-mm-long chirp is nearly 4 db greater for the 2 0.3% strain experiment than for the single 0.6% applied strain experiment. Fig. 5(a) shows the LMTF curves for each pulse type when the correlation window length (0.077 mm) is shorter than all of the compressed pulse lengths (0.17 mm for the short pulse). For these curves, we studied the strain impulse software phantom. These LMTF curves define the upper limit of axial resolution because pulse length is the limiting factor [17]. Fig. 5(b) shows the LIR when the correlation window is longer than transducer pulse for the short and chirp pulses. The width of the main lobe shows the attainable resolution determined by the correlation window [17]. Fig. 5(a) predicts a small degradation in

6 236 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february 2005 TABLE II Experimental System 6 db Resolution (mm). Resolution Short Chirp Barker Axial Lateral Fig. 4. SNR d for chirp pulses as a function of pulse length under applied strains 0.3%, 0.6%, and 2 0.3% (multicompression), respectively. The correlation window length is 1.23 mm, esnr =40dB, and attenuation coefficient = 0.6 db/cm/mhz are fixed. upper bound resolution when coded excitation is applied. However, Fig. 5(b) shows coded excitation has lower strain noise under the same attainable resolution. Therefore, the increased SNR d with coded pulse excitation permits use of shorter correlation windows and higher frequencies that enhance displacement and strain axial resolution. Fig. 6 shows SNR d for the short and chirp pulses as a function of correlation window length (attainable resolution) using the homogeneous phantom. For example, SNR d =20dB with a short pulse when the correlation window is 3.1 mm. However, we can obtain the same SNR d using a chirp pulse with a 1.75-mm correlation window. Consequently, the relative spatial resolution for strain can be increased using coded excitation in low esnr conditions. A. The Experiment IV. Phantom Measurements We developed an ultrasonic strain imaging system [20] specifically for imaging tumors in small animals. An 8- ring, 30-mm diameter, f/1.5, spherically focused annular array was built to generate 10 MHz pulses with 60% bandwidth [21]. This transducer dynamically focuses on receive without aperture growth. Echoes are recorded with a sampling rate of 62.5 MHz while the transducer is mechanically scanned by a linear positioner under microprocessor control. The 6 db depth of focus (DOF) for B-mode imaging is extended from 2.4 mm to just 3.2 mm after dynamic focusing. Therefore, the esnr remained insufficient for strain imaging over a 10-mm depth near the focal length because of significant decorrelation errors from low esnr. We applied chirp and 13-bit Barker pulses designed to increase esnr and allow decorrelation-free strain imaging over a 10-mm DOF. The lengths of the short, chirp (Tukey apodized), and Barker pulses were mm (TBP 1), 2.65 mm, and 2.17 mm (TBP 10), respectively. For all sequences, the peak-to-peak excitation voltages (V pp = 200v) and bandwidths were kept constant. The transmitted energy was held constant for all coded sequences. Consequently, the expected increase in esnr was 10 db. We measured an increase in the 6 db DOF from 3.2 mm to 7 mm. A 35 mm 10 mm graphite/agar phantom having acoustic properties similar to breast tissue was built for strain imaging. Measured attenuation is 5.4 db/cm at 10 MHz. Three hard inclusions with diameter 2.5 mm were embedded at 2-mm, 5-mm, and 8-mm depths. The transmit focal zone is centered on the 5-mm deep inclusion. This lesion-mimicking phantom can be used to study lesion visibility via CNR ɛ. The estimate of the ratio of the elastic modulii of the background and inclusions is about 5 6. All processing was performed off-line on Pentium computers. When phantom strain images are computed, 2-D companding techniques [9] are applied to reduce out-ofplane motion and the amount of strain between g 1 and g 2 before cross correlation. Thus, the residual strain detected by the correlation estimator is less than 1%. B. Experiment Results We measured 2-D spatial sensitivity function (SSF) [22] for the short, chirp, and Barker pulses along the lateral (x) and axial(z) directions by scanning a point reflector in two different ways. First, we scanned the point reflector by moving the transducer on a fine mesh and recorded the peak pulse amplitude. The results are the SSF shown in Fig. 7. Penetration is greatly extended by coded excitation with some increase in range and side lobes. The second measurement fixes the reflector in space at the focal length (45 mm) and records the echo amplitude as a function of time (axially) and space (laterally). Axial point spread function (PSF) and lateral SSF functions for short, chirp, and Barker pulses are demonstrated in Fig. 8 and Table II. Long pulse excitation degrades B-mode axial resolution due to blurring by the base sequence as predicted by simulation results, Fig. 5(a). Lateral resolution is determined by the product of wavelength and f-number, λ f/no = =0.22 mm, which is unaffected by the applied voltage, Fig. 8(b). Range lobes for the 13-bit Barker code are 22 db lower than the main lobe peak in the axial direction, Fig. 8(a), and 6 db lower in lateral direction.

7 liu and insana: comparative studies of strain imaging 237 Fig. 5. (a) LMTF curves for short pulse, chirp pulse, 7-bit Barker code, and 8-bit Golay code. The correlation window length is mm. esnr = 1000 db. Applied strain is 1%. (b) LIR for short pulse and chirp pulse under same attainable resolution. The correlation window length is 0.62 mm, esnr =40dB,andappliedstrainis1%. Fig. 6. SNR d for short and chirp pulse as a function of window length. esnr = 40 db, attenuation coefficient 0.6 db/cm/mhz, and 0.5% applied strain are fixed. Fig. 9 shows strain images of the lesion phantom for applied strains of 1%, 2%, and 3%, using short, chirp, and Barker pulses, respectively. Measured CNR ɛ results from data in Fig. 9 are listed in Table III. Square boxes in Fig. 9 indicate regions from which CNR ɛ in Table III are computed. The peak esnr measured for our laboratory system is a meager 30 db for the lesion phantom. Images in Fig. 9 are displayed with the same gray scale to show how greater phantom compression increases lesion contrast and decorrelation noise, particularly for the short and Barker pulses. Comparing the strain images, it is clear that the chirp pulse can successfully suppress decorrelation strain noise under noise-limited condition. Although the Barker pulse improves esnr, its range side lobes induce decorrelation noise at larger deformations. Its performance is Fig. 7. Measured 2-D SSF for short, chirp, and Barker sequences. TABLE III CNR ɛ Measured for Lesion Phantom in Fig. 9. Strain Short Chirp Barker 1% % % equivalent to the short pulse as predicted by the simulation results, Fig. 2(a). Fig. 10 compares the strain images of a lesion phantom with 1% applied strain for short pulse and chirp pulse using 1.58-mm and 0.79-mm correlation window lengths. Measured CNR ɛ results are shown in Table IV. Chirp pulses provide greater CNR ɛ than short pulses with

8 238 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february 2005 Fig. 8. Measured axial PSF (a) and lateral SSF (b) for short, chirp, and Barker pulses at focal depth. Fig. 9. Strain images of a lesion phantom with 1%, 2%, and 3% strain applied from top. The excitation pulses are the short pulse (left column), chirp (middle column), and Barker code (right column). The correlation window is fixed at 1.58 mm. Each image size is 13.3 mm 10.7 mm. Boxes indicate regions from which strain contrast to noise ratios in Table III are computed. TABLE IV CNR ɛ Measured for Lesion Phantom in Fig. 10. Fig. 10. Strain images of a lesion phantom with 1% applied strain. The excitation pulses are short (left) and chirp (right). The correlation windows are 1.58 mm and 0.79 mm from top to bottom, respectively. Each image size is 8.8 mm 10.7 mm. the same correlation window length. From Table IV, the chirp pulse has almost the equal CNR ɛ as the short pulse but with half the window length. Recall that the window length determines the attainable axial resolution for strain imaging. Therefore, to keep the same lesion detectability, the chirp pulse requires a shorter correlation window. Window length Short Chirp 1.58 mm mm V. Discussion and Conclusions This paper describes a method for adapting common coded excitation pulses to strain imaging. It also presents

9 liu and insana: comparative studies of strain imaging 239 a preliminary study based on simulated echo data using parameters of the Siemens Antares system as well as phantom experiments using a laboratory system. We compared the performance of conventional short pulse and coded pulse excitations under the operating conditions of breast imaging. The measured results demonstrate that it is feasible to apply coded excitation technique for ultrasonic strain imaging. Many operating factors (such as electronic noise, ultrasonic attenuation, and applied deformation) will affect strain image quality. To maximize the performance, the coding parameters must be carefully chosen. To obtain the highest performance, the choice of pulse and associated parameters is application dependent. Fig. 2(a) shows that, when esnr > 50 db, SNR d is greatest for the short pulse. When esnr < 50 db, the chirp and Golay pulses yield the lowest strain noise. It suggests that to obtain a low-noise strain image along an extended field of view, one should apply short pulses in high esnr regions (for example, near the focus), and coded long pulses should be applied in low esnr regions (e.g., in which there is acoustic shadowing or deep in the body). Fig. 2(b) predicts that coded excitation significantly reduces strain noise in highly absorbing tissue. The estimated attenuation for fibroglandular tissue in breast is 22.8 db/cm for a 10 MHz transducer [23]. The slope of ultrasonic attenuation for some carcinomas is about db/cm/mhz [24]. Coded excitation has great potential for reducing strain noise in absorbing media such as breast tissue. The greatest improvement in SNR d with coded pulses is obtained at the smallest applied deformations, e.g., Fig. 3(a). Also small deformations allow use of longer code [see Fig. 3(b)]. Both of these results suggest that multicompression methods combined with coded excitation will be very effective, e.g., see Fig. 4. A previous study [17] showed that B-mode axial resolution determines the upper bound for strain axial resolution. For our approach to coded excitation, the upper limit on axial resolution is further limited by the base sequence as given by h sb and shown in Fig. 5(a), Fig. 8(a), and Table II results. Using the spatial frequency at LMTF = 0.1 as the axial resolution limit [17], predictions in Fig. 5(a) agree with the measurements in Fig. 8(a). However, in common practice, the duration of the correlation window determines attainable axial resolution. Fig. 5(b), Fig. 10, and Table IV demonstrate the improvement in SNR d using coded pulses can be converted to improvement in attainable axial resolution. The lateral resolution in strain imaging is on the same order as in B-mode [25]. Because the coding and decoding procedure have no effect on transducer aperture size, lateral resolution remains unchanged by the excitation [see Fig. 8(b)]. Our comparative study of the performances of chirp, Barker, suboptimal, and Golay codes shows that designing sequences robust to deformations is challenging for strain imaging. The simulations predict chirp and Golay code have better performance than suboptimal and Barker code. Experiments verify the predictions that it is easier to detect small lesions using chirp pulse than Barker code under noise-limited condition. Due to our limited hardware, Golay code excitation was not tested during experiments. However, because the experimental results using chirp and Barker codes agree with predictions, we expect the Golay code predictions to be verified also. A variety of other codes available for ultrasonic imaging will be studied in our future work, such as m-sequence and Huffman sequence [15]. Matched filters were used to decode echoes. Although this approach maximizes esnr, it introduces range lobes. As the simulations and experiments showed, range lobes act to decorrelate echoes in deformed media. For Barker and suboptimal codes, the level of the range lobe is often too high for strain imaging, roughly 20 db below that of the main lobe. Echoes also may be decoded by inverse compression filters or an adaptive combination of matched and inverse filtering given by the Wiener filter [7]. For a general compression filter h c, the echo signal in (3) is written as: g j [n] = m= h c [m n]g j[m], where the system response of the filter is: H c [k] = C [k] C[k] 2 + E{ E [k]l 2 } /E{ S [k] 2 }, (9) and C [k], S [k], and E [k] are the discrete Fourier transforms of c [ n], s [n], and e [n], respectively. The compression filter H c is approximately proportional to the match filter C [k] when the noise power is relatively large and the inverse filter C 1 [k] with the noise power is relatively small. We focused the matched filter over the inverse filter because of its greater stability in noisy conditions, its ease of use, and its ability to achieve the largest esnr regardless of the code [8]. The goal is to design C[k] to be constant over the transducer bandwidth. In that case the matched and inverse filters perform equivalently within a scale factor. References [1] Y. Wang, K. Metzger, D. N. Stephens, G. Williams, S. Brownlie, and M. O Donnell, Coded excitation with spectrum inversion (CEXSI) for ultrasound array imaging, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 50, pp , [2] A. Nowicki, J. Litniewski, W. Secomski, P. A. Lewin, and I. Trots, Estimation of ultrasonic attenuation in a bone using coded excitation, Ultrasonics, vol. 41, pp , [3] J.M.G.Borsboom,C.T.Chin,andN.deJong, Nonlinear coded excitation method for ultrasound contrast imaging, Ultrasound Med. Biol., vol. 29, pp , [4] J. Shen and E. S. Ebbini, Filter-based coded-excitation system for high-speed ultrasonic imaging, IEEE Trans. Med. Imag., vol. 17, pp , [5] T. Misaridis and J. A. Jensen, Space-time encoding for high frame rate ultrasound imaging, Ultrasonics, vol. 40, pp , [6] M. O Donnell, Coded excitation systems for improving the penetration of real-time phased-array imaging systems, IEEE

10 240 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, february 2005 Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp , [7] B. Haider, P. A. Lewin, and K. E. Thomenius, Pulse elongation and deconvolution filtering for medical ultrasonic imaging, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, pp , [8] R. Y. Chiao and X. Hao, Coded excitation for diagnostic ultrasound: A system developer s perspective, in Proc. IEEE Ultrason. Symp., 2003, pp [9] R. Y. Chiao and X. Hao, 2-D companding for noise reduction in strain imaging, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, pp , [10] P. Chaturvedi, M. F. Insana, and T. Hall, Testing the limitations of 2-D local companding in strain imaging using phantoms, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, pp , [11] J. Ruprecht and M. Ropf, On the search for good aperiodic binary invertable sequences, IEEE Trans. Inform. Theory, vol. 42, pp , [12]A.V.Oppenheim,R.W.Schafer,andJ.R.Buck,Discrete-Time Signal Processing. Upper Saddle River, NJ: Prentice-Hall, [13] E. C. Farnett and G. H. Stevens, Pulse compression radar, in Radar Handbook. 2nd ed. M. Skolnik, Ed. New York: McGraw- Hill, 1990, pp [14] F. J. Harris, On the use of windows for harmonic analysis with the discrete Fourier transform, Proc. IEEE, vol. 66, pp , [15] M. A. Benkhelifa, M. Gindre, J. L. Hureou, and W. Urbach, Echography using correlation techniques: Choice of coding signal, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 41, pp , [16] Y. C. Fung, A First Course in Continuum Mechanics for Physical and Biological Engineers and Scientists. 3rd ed. Engelwood Cliffs, NJ: Prentice-Hall, 1994, pp [17] J. Liu, C. K. Abbey, and M. F. Insana, Linear approach to axial resolution in elasticity imaging, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 51, no. 6, pp , [18] W. F. Walker, The significance of correlation in ultrasound signal processing, Proc. SPIE, vol. 4325, pp , [19] T. Varghese and J. Ophir, Performance optimization in elastography: Multicompression with temporal stretching, Ultrason. Imag., vol. 18, pp , [20] C. Kargel, G. Plevnik, B. Trummer, and M. F. Insana, Doppler ultrasound systems designed for tumor blood flow imaging, IEEE Trans. Instrum. Meas., vol. 53, pp , [21] H. S. Mhanna, B. Trummer, C. Kargel, and M. F. Insana, Ultrasonic annular array system for detecting tissue motion, Proc. SPIE, vol. 4687, pp , [22] R. J. Zemp, C. K. Abbey, and M. F. Insana, Linear system models for ultrasonic imaging: Application to signal statistics, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 50, pp , [23] M. E. Anderson, M. S. Soo, and G. E. Trahey, In vivo breast tissue backscatter measurements with 7.5- and 10-MHz transducers, Ultrasound Med. Biol., vol. 27, pp , [24] L. Landini, R. Sarnelli, and F. Squartini, Frequency-dependent attenuation in breast tissue characterization, Ultrasound Med. Biol., vol. 11, pp , [25] R. Reghetti, S. Srinivasan, and J. Ophir, Lateral resolution in elastography, Ultrasound Med. Biol., vol. 29, pp , Jie Liu received her B.S. degree and M.S. degree in Biomedical Instrument from Tianjin University, Tianjin, China, in 1995 and She obtained her Ph.D. in Biomedical Engineering from the Tsinghua University, Beijing, China, in She was a Senior Research Fellow in the Bioengineering department, University of Washington, Seattle, WA, from 2001 to She has been a Postdoctoral Researcher of Biomedical Engineering at the University of California, Davis, Davis, CA, since July, Her research interests include developing advanced scientific theories, methods, and research techniques in medical ultrasonic imaging systems and evaluating their performances in terms of diagnostic tasks. MichaelF.Insana(M 84) earned a B.S. in physics from Oakland University, Rochester, MI, in 1978 and the M.S. and Ph.D. degrees in medical physics from the University of Wisconsin, Madison, WI, in 1982 and 1983, respectively. He was a staff physicist at the Center for Devices and Radiological Health, U.S. Food and Drug Administration, Rockville, MD, from working on ultrasonic tissue characterization, statistical analysis, and pattern recognition methods. From , Mike was professor of Radiology and Physiology at University of Kansas Medical Center, Kansas City, KS, where he conducted ultrasonics research involving the detection and progression of renal diseases. His research activities include inverse scattering problems, elasticity imaging, biomaterials development, and observer performance experiments characterizing imaging systems. Since 1999, Mike has been Professor of Biomedical Engineering at the University of California, Davis, Davis, CA. He teaches courses on image science, signal processing, and system design and performance evaluation. Current research interests include wall-filters for strain-flow vascular imaging, elasticity imaging of breast tumors, coded-excitation approaches for B-mode, elasticity and Doppler estimation, and tissue-like phantoms. He is a member of the IEEE, the Acoustical Society of America, and a Fellow of the Institute of Physics.

PII S (98) AN ANALYSIS OF ELASTOGRAPHIC CONTRAST-TO-NOISE RATIO

PII S (98) AN ANALYSIS OF ELASTOGRAPHIC CONTRAST-TO-NOISE RATIO PII S0301-5629(98)00047-7 Ultrasound in Med. & Biol., Vol. 24, No. 6, pp. 915 924, 1998 Copyright 1998 World Federation for Ultrasound in Medicine & Biology Printed in the USA. All rights reserved 0301-5629/98

More information

Original Contribution

Original Contribution PII: S030-5629(0)00379-9 Ultrasound in Med. & Biol., Vol. 27, No. 6, pp. 89 827, 200 Copyright 200 World Federation for Ultrasound in Medicine & Biology Printed in the USA. All rights reserved 030-5629/0/$

More information

Correlation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers

Correlation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers Correlation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers Min Rao a and Tomy Varghese Department of Medical Physics, The University of Wisconsin-Madison,

More information

31545 Medical Imaging systems

31545 Medical Imaging systems Simulation of ultrasound systems and non-linear imaging 545 Medical Imaging systems Lecture 9: Simulation of ultrasound systems and non-linear imaging Jørgen Arendt Jensen Department of Electrical Engineering

More information

Plane Wave Medical Ultrasound Imaging Using Adaptive Beamforming

Plane Wave Medical Ultrasound Imaging Using Adaptive Beamforming Downloaded from orbit.dtu.dk on: Jul 14, 2018 Plane Wave Medical Ultrasound Imaging Using Adaptive Beamforming Voxen, Iben Holfort; Gran, Fredrik; Jensen, Jørgen Arendt Published in: Proceedings of 5th

More information

Original Contribution

Original Contribution PII S0301-5629(00)00199-X Ultrasound in Med. & Biol., Vol. 26, No. 5, pp. 839 851, 2000 Copyright 2000 World Federation for Ultrasound in Medicine & Biology Printed in the USA. All rights reserved 0301-5629/00/$

More information

Elasticity imaging describes a broad range of emerging

Elasticity imaging describes a broad range of emerging ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 1, january 1998 179 2-D Companding for Noise Reduction in Strain Imaging Pawan Chaturvedi, Member, IEEE, Michael F.

More information

EXPERIMENTAL VALIDATION OF THE SPECTRAL FIT ALGORITHM USING TISSUE MIMICKING PHANTOMS

EXPERIMENTAL VALIDATION OF THE SPECTRAL FIT ALGORITHM USING TISSUE MIMICKING PHANTOMS EXPERIMENTAL VALIDATION OF THE SPECTRAL FIT ALGORITHM USING TISSUE MIMICKING PHANTOMS T.A. Bigelow, W.D. O Brien, Jr. Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering,

More information

Ultrasound is a widely used, nonionizing, and costeffective

Ultrasound is a widely used, nonionizing, and costeffective 340 IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 57, no. 2, February 2010 Trade-Offs in Data Acquisition and Processing Parameters for Backscatter and Scatterer Size Estimations

More information

Microwave-induced thermoacoustic tomography using multi-sector scanning

Microwave-induced thermoacoustic tomography using multi-sector scanning Microwave-induced thermoacoustic tomography using multi-sector scanning Minghua Xu, Geng Ku, and Lihong V. Wang a) Optical Imaging Laboratory, Biomedical Engineering Program, Texas A&M University, 3120

More information

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a). 7.1. Low-Coherence Interferometry (LCI) Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a). The light is split by the beam splitter (BS) and

More information

Lateral Blood Flow Velocity Estimation Based on Ultrasound Speckle Size Change With Scan Velocity

Lateral Blood Flow Velocity Estimation Based on Ultrasound Speckle Size Change With Scan Velocity University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Biomedical Imaging and Biosignal Analysis Laboratory Biological Systems Engineering 12-2010 Lateral Blood Flow Velocity

More information

ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 1, january Multiresolution Imaging in Elastography

ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 1, january Multiresolution Imaging in Elastography ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no., january 998 65 Multiresolution Imaging in Elastography Tomy Varghese, Member, IEEE, Mehmet Bilgen, Member, IEEE, and

More information

Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence on Scan Direction and A-Line Acquisition Velocity

Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence on Scan Direction and A-Line Acquisition Velocity University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Biological Systems Engineering: Papers and Publications Biological Systems Engineering 5-2013 Two-Dimensional Blood Flow

More information

Fast simulation of nonlinear radio frequency ultrasound images in inhomogeneous nonlinear media: CREANUIS

Fast simulation of nonlinear radio frequency ultrasound images in inhomogeneous nonlinear media: CREANUIS Proceedings of the Acoustics 2012 Nantes Conference Fast simulation of nonlinear radio frequency ultrasound images in inhomogeneous nonlinear media: CREANUIS F. Varray a, M. Toulemonde a,b, O. Basset a

More information

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam (closed book, 1 sheets of notes double sided allowed, no calculator or other electronic devices allowed) 1. Ultrasound Physics (15 pt) A) (9

More information

Ultrasonics. Principal component analysis of shear strain effects. Hao Chen, Tomy Varghese * abstract. Contents lists available at ScienceDirect

Ultrasonics. Principal component analysis of shear strain effects. Hao Chen, Tomy Varghese * abstract. Contents lists available at ScienceDirect Ultrasonics 49 (2009) 472 483 Contents lists available at ScienceDirect Ultrasonics journal homepage: www.elsevier.com/locate/ultras Principal component analysis of shear strain effects Hao Chen, Tomy

More information

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor Institute of Physics Publishing Journal of Physics: Conference Series 1 (2004) 140 145 doi:10.1088/1742-6596/1/1/032 Advanced Metrology for Ultrasound in Medicine Output intensity measurement on a diagnostic

More information

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar. 1 Doppler echocardiography & Magnetic Resonance Imaging History: - Langevin developed sonar. - 1940s development of pulse-echo. - 1950s development of mode A and B. - 1957 development of continuous wave

More information

/96$ IEEE

/96$ IEEE IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL, VOL. 43, NO. 5, SEPTEMBER 1996 979 Correspondence Order Selection Criteria for Detecting Mean Scatterer Spacings with the AR Model

More information

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI Institute of Fundamental Technological Research, Department

More information

N db compared with that in the single pulse harmonic imaging mode, whereas

N db compared with that in the single pulse harmonic imaging mode, whereas 26 at UMass Dartmouth, N. Dartmouth, MA Proceedings published in www.ndt.net Acoustic nonlinear imaging and its application in tissue characterization * Dong Zhang and Xiu-fen Gong Lab. of Modern Acoustics,

More information

Workshop 2: Acoustic Output Measurements

Workshop 2: Acoustic Output Measurements 37 th th UIA Symposium, Washington DC Workshop 2: Acoustic Output Measurements Mark Hodnett Senior Research Scientist Quality of Life Division National Physical Laboratory Teddington Middlesex, UK Workshop

More information

Simulation of Contrast Agent Enhanced Ultrasound Imaging based on Field II

Simulation of Contrast Agent Enhanced Ultrasound Imaging based on Field II Simulation of Contrast Agent Enhanced Ultrasound Imaging based on Field II Tobias Gehrke, Heinrich M. Overhoff Medical Engineering Laboratory, University of Applied Sciences Gelsenkirchen tobias.gehrke@fh-gelsenkirchen.de

More information

Pixel-based Beamforming for Ultrasound Imaging

Pixel-based Beamforming for Ultrasound Imaging Pixel-based Beamforming for Ultrasound Imaging Richard W. Prager and Nghia Q. Nguyen Department of Engineering Outline v Introduction of Ultrasound Imaging v Image Formation and Beamforming v New Time-delay

More information

DOPPLER-BASED ULTRASONIC BLOOD VELOCITY ESTIMATION

DOPPLER-BASED ULTRASONIC BLOOD VELOCITY ESTIMATION DOPPLER-BASED ULTRASONIC BLOOD VELOCITY ESTIMATION BY TOROS ARIKAN THESIS Submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Electrical and Computer Engineering

More information

10. OPTICAL COHERENCE TOMOGRAPHY

10. OPTICAL COHERENCE TOMOGRAPHY 1. OPTICAL COHERENCE TOMOGRAPHY Optical coherence tomography (OCT) is a label-free (intrinsic contrast) technique that enables 3D imaging of tissues. The principle of its operation relies on low-coherence

More information

EE 5345 Biomedical Instrumentation Lecture 6: slides

EE 5345 Biomedical Instrumentation Lecture 6: slides EE 5345 Biomedical Instrumentation Lecture 6: slides 129-147 Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be viewed at: http:// www.seas.smu.edu/~cd/ee5345.html

More information

SCATTERING OF ULTRASONIC WAVE ON A MODEL OF THE ARTERY J. WÓJCIK, T. POWAŁOWSKI, R. TYMKIEWICZ A. LAMERS, Z. TRAWIŃSKI

SCATTERING OF ULTRASONIC WAVE ON A MODEL OF THE ARTERY J. WÓJCIK, T. POWAŁOWSKI, R. TYMKIEWICZ A. LAMERS, Z. TRAWIŃSKI ARCHIVES OF ACOUSTICS 31, 4, 471 479 (2006) SCATTERING OF ULTRASONIC WAVE ON A MODEL OF THE ARTERY J. WÓJCIK, T. POWAŁOWSKI, R. TYMKIEWICZ A. LAMERS, Z. TRAWIŃSKI Institute of Fundamental Technological

More information

Blind Deconvolution of Ultrasonic Signals Using High-Order Spectral Analysis and Wavelets

Blind Deconvolution of Ultrasonic Signals Using High-Order Spectral Analysis and Wavelets Blind Deconvolution of Ultrasonic Signals Using High-Order Spectral Analysis and Wavelets Roberto H. Herrera, Eduardo Moreno, Héctor Calas, and Rubén Orozco 3 University of Cienfuegos, Cuatro Caminos,

More information

Today s menu. Last lecture. Ultrasonic measurement systems. What is Ultrasound (cont d...)? What is ultrasound?

Today s menu. Last lecture. Ultrasonic measurement systems. What is Ultrasound (cont d...)? What is ultrasound? Last lecture Measurement of volume flow rate Differential pressure flowmeters Mechanical flowmeters Vortex flowmeters Measurement of mass flow Measurement of tricky flows" Today s menu Ultrasonic measurement

More information

Physics and Knobology

Physics and Knobology Physics and Knobology Cameron Jones, MD 02/01/2012 SOUND: Series of pressure waves traveling through a medium What is ULTRASOUND Physics Words WAVELENGTH: Distance traveled in one cycle FREQUENCY: number

More information

Original Contribution

Original Contribution PII S0301-5629(98)00109-4 Ultrasound in Med. & Biol., Vol. 24, No. 8, pp. 1183 1199, 1998 Copyright 1998 World Federation for Ultrasound in Medicine & Biology Printed in the USA. All rights reserved 0301-5629/98

More information

Ultrasonic elasticity imaging has been studied for

Ultrasonic elasticity imaging has been studied for IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 57, no. 12, December 2010 2833 Correspondence A Normalization Method for Axial- Shear Strain Elastography Lujie Chen, R. James

More information

Bioengineering 280A Principles of Biomedical Imaging. Fall Quarter 2006 Ultrasound Lecture 1

Bioengineering 280A Principles of Biomedical Imaging. Fall Quarter 2006 Ultrasound Lecture 1 Bioengineering 280A Principles of Biomedical Imaging Fall Quarter 2006 Ultrasound Lecture 1 From Suetens 2002 1 Basic System Echo occurs at t=2z/c where c is approximately 1500 m/s or 1.5 mm/µs Macovski

More information

Physical principles of Harmonic Imaging Min Joo Choi, PhD

Physical principles of Harmonic Imaging Min Joo Choi, PhD Physical principles of Harmonic Imaging Min Joo Choi, PhD Department Biomedical Engineering College of Medicine, Cheju National University School of Medicine, King s College of London, University of London

More information

MODEL SELECTION IN ULTRASONIC MEASUREMENTS ON TRABECULAR BONE

MODEL SELECTION IN ULTRASONIC MEASUREMENTS ON TRABECULAR BONE MODEL SELECTION IN ULTRASONIC MEASUREMENTS ON TRABECULAR BONE Christian C. Anderson, M.A., Karen R. Marutyan, Ph.D., Keith A. Wear Ph.D., Mark R. Holland, Ph.D., James G. Miller, Ph.D. and G. Larry Bretthorst,

More information

Technical University of Denmark

Technical University of Denmark Technical University of Denmark Page 1 of 11 pages Written test, 9 December 2010 Course name: Introduction to medical imaging Course no. 31540 Aids allowed: none. "Weighting": All problems weight equally.

More information

Interlaboratory Comparison of Backscatter Coefficient Estimates for Tissue-Mimicking Phantoms

Interlaboratory Comparison of Backscatter Coefficient Estimates for Tissue-Mimicking Phantoms ULTRASONIC IMAGING 32, 48-64 (2010) Interlaboratory Comparison of Backscatter Coefficient Estimates for Tissue-Mimicking Phantoms JANELLE J. ANDERSON, 1 MARIA-TERESA HERD, 1 MICHAEL R. KING, 2 ALEXANDER

More information

Spectral Velocity Estimation in the Transverse Direction

Spectral Velocity Estimation in the Transverse Direction Paper presented at the IEEE International Ultrasonics Symposium, Prague, Czech Republic, 3: Spectral Velocity Estimation in the Transverse Direction Jørgen Arendt Jensen Center for Fast Ultrasound Imaging,

More information

A method of the forward problem for magneto-acousto-electrical tomography

A method of the forward problem for magneto-acousto-electrical tomography Technology and Health Care 24 (216) S733 S738 DOI 1.3233/THC-16122 IOS Press S733 A method of the forward problem for magneto-acousto-electrical tomography Jingxiang Lv a,b,c, Guoqiang Liu a,, Xinli Wang

More information

Basic System. Basic System. Sonosite 180. Acuson Sequoia. Echo occurs at t=2z/c where c is approximately 1500 m/s or 1.5 mm/µs

Basic System. Basic System. Sonosite 180. Acuson Sequoia. Echo occurs at t=2z/c where c is approximately 1500 m/s or 1.5 mm/µs Bioengineering 280A Principles of Biomedical Imaging Fall Quarter 2007 Ultrasound Lecture Sonosite 80 From Suetens 2002 Acuson Sequoia Basic System Basic System Echo occurs at t=2/c where c is approximately

More information

Estimating the spatial autocorrelation function for ultrasound scatterers in isotropic media

Estimating the spatial autocorrelation function for ultrasound scatterers in isotropic media Estimating the spatial autocorrelation function for ultrasound scatterers in isotropic media Jiang-Feng Chen, a) James A. Zagzebski, b) Fang Dong, and Ernest L. Madsen Department of Medical Physics, University

More information

COMPARISON OF THE PERFORMANCE OF DIFFERENT TIME DELAY ESTIMATION TECHNIQUES FOR ULTRASOUND ELASTOGRAPHY. A Thesis SRINATH SAMBASUBRAMANIAN

COMPARISON OF THE PERFORMANCE OF DIFFERENT TIME DELAY ESTIMATION TECHNIQUES FOR ULTRASOUND ELASTOGRAPHY. A Thesis SRINATH SAMBASUBRAMANIAN COMPARISON OF THE PERFORMANCE OF DIFFERENT TIME DELAY ESTIMATION TECHNIQUES FOR ULTRASOUND ELASTOGRAPHY A Thesis by SRINATH SAMBASUBRAMANIAN Submitted to the Office of Graduate Studies of Texas A&M University

More information

SENSITIVITY TO POINT-SPREAD FUNCTION PARAMETERS IN MEDICAL ULTRASOUND IMAGE DECONVOLUTION

SENSITIVITY TO POINT-SPREAD FUNCTION PARAMETERS IN MEDICAL ULTRASOUND IMAGE DECONVOLUTION SENSITIVITY TO POINT-SPREAD FUNCTION PARAMETERS IN MEDICAL ULTRASOUND IMAGE DECONVOLUTION H.-C. Shin, R. W. Prager, J. K. H. Ng, W. H. Gomersall, N. G. Kingsbury, G. M. Treece and A. H. Gee CUED / F-INFENG

More information

Magnetoacoustic tomography with current injection

Magnetoacoustic tomography with current injection Article Progress of Projects Supported by NSFC Materials Science October 23 Vol.58 No.3: 36366 doi:.7/s434-3-5964-2 Magnetoacoustic tomography with current injection LIU GuoQiang *, HUANG Xin,2, XIA Hui

More information

BNG/ECE 487 FINAL (W16)

BNG/ECE 487 FINAL (W16) BNG/ECE 487 FINAL (W16) NAME: 4 Problems for 100 pts This exam is closed-everything (no notes, books, etc.). Calculators are permitted. Possibly useful formulas and tables are provided on this page. Fourier

More information

Lamb Wave Behavior in Bridge Girder Geometries

Lamb Wave Behavior in Bridge Girder Geometries Lamb Wave Behavior in Bridge Girder Geometries I. J. Oppenheim a*, D. W. Greve b, N. L. Tyson a a Dept. of Civil and Environmental Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 b Dept.

More information

Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments

Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments Iowa State University From the SelectedWorks of Timothy A. Bigelow July, 2004 Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments

More information

Sound wave bends as it hits an interface at an oblique angle. 4. Reflection. Sound wave bounces back to probe

Sound wave bends as it hits an interface at an oblique angle. 4. Reflection. Sound wave bounces back to probe : Ultrasound imaging and x-rays 1. How does ultrasound imaging work?. What is ionizing electromagnetic radiation? Definition of ionizing radiation 3. How are x-rays produced? Bremsstrahlung Auger electron

More information

Optimisation using measured Green s function for improving spatial coherence in acoustic measurements

Optimisation using measured Green s function for improving spatial coherence in acoustic measurements Ultrasonics 42 (2004) 205 212 www.elsevier.com/locate/ultras Optimisation using measured Green s function for improving spatial coherence in acoustic measurements Matthew Clark *, Steve D. Sharples, Mike

More information

Angular Spectrum Decomposition Analysis of Second Harmonic Ultrasound Propagation and its Relation to Tissue Harmonic Imaging

Angular Spectrum Decomposition Analysis of Second Harmonic Ultrasound Propagation and its Relation to Tissue Harmonic Imaging The 4 th International Workshop on Ultrasonic and Advanced Methods for Nondestructive Testing and Material Characterization, June 9, 006 at ABSTRACT Angular Spectrum Decomposition Analysis of Second Harmonic

More information

CAPABILITY OF SEGMENTED ANNULAR ARRAYS TO GENERATE 3-D ULTRASONIC IMAGING

CAPABILITY OF SEGMENTED ANNULAR ARRAYS TO GENERATE 3-D ULTRASONIC IMAGING CAPABILITY O SEGMENTED ANNULAR ARRAYS TO GENERATE 3-D ULTRASONIC IMAGING PACS RE.: 43.38.HZ, 43.35, 43.35.BC, 43.60 Ullate Luis G.; Martínez Oscar; Akhnak Mostafa; Montero rancisco Instituto de Automática

More information

Efficient Algorithms for Pulse Parameter Estimation, Pulse Peak Localization And Pileup Reduction in Gamma Ray Spectroscopy M.W.Raad 1, L.

Efficient Algorithms for Pulse Parameter Estimation, Pulse Peak Localization And Pileup Reduction in Gamma Ray Spectroscopy M.W.Raad 1, L. Efficient Algorithms for Pulse Parameter Estimation, Pulse Peak Localization And Pileup Reduction in Gamma Ray Spectroscopy M.W.Raad 1, L. Cheded 2 1 Computer Engineering Department, 2 Systems Engineering

More information

CHAPTER 2 CHARACTERIZATION OF THE REC TECHNIQUE

CHAPTER 2 CHARACTERIZATION OF THE REC TECHNIQUE CHAPTER 2 CHARACTERIZATION OF THE REC TECHNIQUE 2.1 The Effects of Nonlinear Distortion on the Compression of REC Echoes 2.1.1 Introduction In ultrasound, when the excitation waveform is low in pressure

More information

Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force

Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force Jpn. J. Appl. Phys. Vol. 42 (2003) pp. 4608 4612 Part 1, No. 7A, July 2003 #2003 The Japan Society of Applied Physics Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic

More information

Optimal Beamforming in Ultrasound Using the Ideal Observer. Craig K. Abbey, Nghia Q. Nguyen, and Michael F. Insana, Senior Member, IEEE

Optimal Beamforming in Ultrasound Using the Ideal Observer. Craig K. Abbey, Nghia Q. Nguyen, and Michael F. Insana, Senior Member, IEEE 178 IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 57, no. 8, August 010 Optimal Beamforming in Ultrasound Using the Ideal Observer Craig K. Abbey, Nghia Q. Nguyen, and Michael

More information

Vector blood velocity estimation in medical ultrasound

Vector blood velocity estimation in medical ultrasound Vector blood velocity estimation in medical ultrasound Jørgen Arendt Jensen, Fredrik Gran Ørsted DTU, Building 348, Technical University o Denmark, DK-2800 Kgs. Lyngby, Denmark Jesper Udesen, Michael Bachmann

More information

The physics US and MRI. Prof. Peter Bogner

The physics US and MRI. Prof. Peter Bogner The physics US and MRI Prof. Peter Bogner Sound waves mechanical disturbance, a pressure wave moves along longitudinal wave compression rarefaction zones c = nl, (c: velocity, n: frequency, l: wavelength

More information

760 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 56, NO. 3, MARCH Min Rao*, Student Member, IEEE, and Tomy Varghese, Senior Member, IEEE

760 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 56, NO. 3, MARCH Min Rao*, Student Member, IEEE, and Tomy Varghese, Senior Member, IEEE 760 IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 56, NO. 3, MARCH 2009 Estimation of the Optimal Maximum Beam Angle and Angular Increment for Normal and Shear Strain Estimation Min Rao*, Student Member,

More information

ESTIMATION OF LAYER THICKNESS BY THE COST FUNCTION OPTIMIZATION: PHANTOM STUDY

ESTIMATION OF LAYER THICKNESS BY THE COST FUNCTION OPTIMIZATION: PHANTOM STUDY ESTIMATION OF LAYER THICKNESS BY THE COST FUNCTION OPTIMIZATION: PHANTOM STUDY JURIJ TASINKIEWICZ, JERZY PODHAJECKI, JANUSZ WOJCIK, KATARZYNA FALIŃSKA, JERZY LITNIEWSKI Ultrasound Department Institute

More information

I. INTRODUCTION J. Acoust. Soc. Am. 115 (6), June /2004/115(6)/3226/9/$ Acoustical Society of America

I. INTRODUCTION J. Acoust. Soc. Am. 115 (6), June /2004/115(6)/3226/9/$ Acoustical Society of America Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter Michael L. Oelze a) and William D. O Brien, Jr. Bioacoustics Research Laboratory,

More information

An Adaptive Strain Estimator for Elastography

An Adaptive Strain Estimator for Elastography IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL, VOL. 45, NO. 2, MARCH 1998 461 An Adaptive Strain Estimator for Elastography S. Kaisar Alam, Member, IEEE, Jonathan Ophir, Member,

More information

CHAPTER 1 INTRODUCTION TO ACOUSTIC SATURATION

CHAPTER 1 INTRODUCTION TO ACOUSTIC SATURATION CHAPTER 1 INTRODUCTION TO ACOUSTIC SATURATION Acoustic saturation states that as the input voltage to a focused ultrasonic transducer increases, there exists a limit of the acoustic pressure at the transducer

More information

THE study of beampatterns and their use in imaging systems

THE study of beampatterns and their use in imaging systems IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL, VOL. 64, NO. 7, JULY 2017 1045 The Ultrasound Needle Pulse Kevin J. Parker, Fellow, IEEE, Shujie Chen, Student Member, IEEE, and

More information

The Physics of Doppler Ultrasound. HET408 Medical Imaging

The Physics of Doppler Ultrasound. HET408 Medical Imaging The Physics of Doppler Ultrasound HET408 Medical Imaging 1 The Doppler Principle The basis of Doppler ultrasonography is the fact that reflected/scattered ultrasonic waves from a moving interface will

More information

Feasibility of non-linear simulation for Field II using an angular spectrum approach

Feasibility of non-linear simulation for Field II using an angular spectrum approach Downloaded from orbit.dtu.dk on: Aug 22, 218 Feasibility of non-linear simulation for using an angular spectrum approach Du, Yigang; Jensen, Jørgen Arendt Published in: 28 IEEE Ultrasonics Symposium Link

More information

Lamb Waves in Plate Girder Geometries

Lamb Waves in Plate Girder Geometries Lamb Waves in Plate Girder Geometries D.W. Greve, 1 N. L. Tyson 2, and I.J. Oppenheim 2 1 Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213 2 Civil and Environmental

More information

Bayesian Speckle Tracking. Part I: An Implementable Perturbation to the Likelihood Function for Ultrasound Displacement Estimation

Bayesian Speckle Tracking. Part I: An Implementable Perturbation to the Likelihood Function for Ultrasound Displacement Estimation 132 IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 60, no. 1, January 2013 Bayesian Speckle Tracking. Part I: An Implementable Perturbation to the Likelihood Function for

More information

Technical University of Denmark

Technical University of Denmark Technical University of Denmark Page 1 of 10 pages Written test, 12 December 2012 Course name: Introduction to medical imaging Course no. 31540 Aids allowed: None. Pocket calculator not allowed "Weighting":

More information

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters Last lecture Analog-to-digital conversion (Ch. 1.1). Introduction to flow measurement systems (Ch. 12.1). Today s menu Measurement of volume flow rate Differential pressure flowmeters Mechanical flowmeters

More information

Ultrasound Image Denoising by Spatially Varying Frequency Compounding

Ultrasound Image Denoising by Spatially Varying Frequency Compounding Ultrasound Image Denoising by Spatially Varying Frequency Compounding Yael Erez 1, Yoav Y. Schechner 1, and Dan Adam 2 1 Dept. Electrical Engineering, Technion Israel Inst. Tech., Haifa 32000, Israel {yaele@tx,

More information

II. METHOD AND MATERIALS

II. METHOD AND MATERIALS REALIZATION OF COMBINED DIAGNOSIS/TREATMENT SYSTEM BY ULTRASOUND STRAIN MEASUREMENT-BASED SHEAR MODULUS RECONSTRUCTION/IMAGING TECHNIQUE EXAMPLES WITH APPLICATION ON THE NEW TYPE INTERSTITIAL RF ELECTROMAGNETIC

More information

Spectral Correlation in Ultrasonic Pulse Echo Signal Processing

Spectral Correlation in Ultrasonic Pulse Echo Signal Processing 330 IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL, VOL. 40, NO. 4, JULY 1993 Spectral Correlation in Ultrasonic Pulse Echo Signal Processing Kevin D. Donohue, Member, IEEE John

More information

Take-Home Final Exam Last Possible Due Date: Dec. 21, 2004, 5 p.m.

Take-Home Final Exam Last Possible Due Date: Dec. 21, 2004, 5 p.m. Take-Home Final Exam Last Possible Due Date: Dec 1, 004, 5 pm Your solutions to the exam should be handed in to the instructor (BIRB 1088) or to Eve Gochis, the MRI lab administrator (BIRB 107) no later

More information

Radar Systems Engineering Lecture 3 Review of Signals, Systems and Digital Signal Processing

Radar Systems Engineering Lecture 3 Review of Signals, Systems and Digital Signal Processing Radar Systems Engineering Lecture Review of Signals, Systems and Digital Signal Processing Dr. Robert M. O Donnell Guest Lecturer Radar Systems Course Review Signals, Systems & DSP // Block Diagram of

More information

Research Article Doppler Velocity Estimation of Overlapping Linear-Period-Modulated Ultrasonic Waves Based on an Expectation-Maximization Algorithm

Research Article Doppler Velocity Estimation of Overlapping Linear-Period-Modulated Ultrasonic Waves Based on an Expectation-Maximization Algorithm Advances in Acoustics and Vibration, Article ID 9876, 7 pages http://dx.doi.org/.55//9876 Research Article Doppler Velocity Estimation of Overlapping Linear-Period-Modulated Ultrasonic Waves Based on an

More information

Virtual Array Processing for Active Radar and Sonar Sensing

Virtual Array Processing for Active Radar and Sonar Sensing SCHARF AND PEZESHKI: VIRTUAL ARRAY PROCESSING FOR ACTIVE SENSING Virtual Array Processing for Active Radar and Sonar Sensing Louis L. Scharf and Ali Pezeshki Abstract In this paper, we describe how an

More information

I have nothing to disclose

I have nothing to disclose Critical Ultrasound for Patient Care April 6-8, 2016 Sonoma, CA Critical Ultrasound for Patient Care I have nothing to disclose April 6-8, 2016 Sonoma, CA UC SF University of California San Francisco UC

More information

DETERMINATION OF THE B/A OF BIOLOGICAL MEDIA BY MEASURING AND MODELING NONLINEAR DISTORTION OF PULSED ACOUSTIC WAVE IN TWO-LAYER MEDIA TAMARA KUJAWSKA

DETERMINATION OF THE B/A OF BIOLOGICAL MEDIA BY MEASURING AND MODELING NONLINEAR DISTORTION OF PULSED ACOUSTIC WAVE IN TWO-LAYER MEDIA TAMARA KUJAWSKA DETERMINATION OF THE B/A OF BIOLOGICAL MEDIA BY MEASURING AND MODELING NONLINEAR DISTORTION OF PULSED ACOUSTIC WAVE IN TWO-LAYER MEDIA TAMARA KUJAWSKA Institute of Fundamental Technological Research Polish

More information

Design of a High Frequency Equal Width Annular Array Transducer for Medical Imaging

Design of a High Frequency Equal Width Annular Array Transducer for Medical Imaging 12 INTERNATIONNAL JOURNAL OF APPLIED BIOMEDICAL ENGINEERING VOL.6, NO.1 2013 Design of a High Frequency Equal Width Annular Array Transducer for Medical Imaging Y. Qian 1 and N. R. Harris 1, ABSTRACT This

More information

High Frame Rate Vector Velocity Estimation using Plane Waves and Transverse Oscillation

High Frame Rate Vector Velocity Estimation using Plane Waves and Transverse Oscillation Downloaded from orbit.dtu.dk on: Nov 1, 218 High Frame Rate Vector Velocity Estimation using Plane Waves and Transverse Oscillation Jensen, Jonas; Stuart, Matthias Bo; Jensen, Jørgen Arendt Published in:

More information

I through the use of a high main magnetic field and high

I through the use of a high main magnetic field and high 330 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 11, NO. 3, SEPTEMBER 1992 Finite Element Analysis of Gradient Coil Deformation and Vibration in NMR Microscopy W. C. Chu, C. B. Ahn, Member, IEEE, B. Bavarian,

More information

Bayesian Speckle Tracking. Part II: Biased Ultrasound Displacement Estimation

Bayesian Speckle Tracking. Part II: Biased Ultrasound Displacement Estimation 144 IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 60, no. 1, January 2013 Bayesian Speckle Tracking. Part II: Biased Ultrasound Displacement Estimation Brett Byram, Student

More information

Use of Taylor Series Expansions for Time Savings in Computation of Accurate Transducer Pressure Fields

Use of Taylor Series Expansions for Time Savings in Computation of Accurate Transducer Pressure Fields IEEE TRANSACTIONS ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL. VOL. UFFC-34, NO. 3, MAY 1987 31 Use of Taylor Series Expansions for Time Savings in Computation of Accurate Transducer Pressure Fields

More information

MODELLING AND SIMULATION OF ULTRASOUND NON LINEARITIES MEASUREMENT FOR BIOLOGICAL MEDIUMS

MODELLING AND SIMULATION OF ULTRASOUND NON LINEARITIES MEASUREMENT FOR BIOLOGICAL MEDIUMS ICSV14 Cairns Australia 9-12 July, 2007 MODELLING AND SIMULATION OF ULTRASOUND NON LINEARITIES MEASUREMENT FOR BIOLOGICAL MEDIUMS Djilali Kourtiche, Rachid Guelaz and Mustapha Nadi LIEN, Nancy-Université,

More information

Research on sound absorbing mechanism and the preparation of new backing material for ultrasound transducers

Research on sound absorbing mechanism and the preparation of new backing material for ultrasound transducers Research on sound absorbing mechanism and the preparation of new backing material for ultrasound transducers Guofeng Bai a) Xiujuan Zhang b) Fusheng Sui c) Jun Yang d) Key Laboratory of Noise and Vibration

More information

Creative Commons: Attribution 3.0 Hong Kong License

Creative Commons: Attribution 3.0 Hong Kong License Title Single-ensemble-based eigen-processing methods for color flow imaging-part I. the Hankel-SVD filter Author(s) Yu, ACH; Cobbold, RSC Citation Ieee Transactions On Ultrasonics, Ferroelectrics, And

More information

Change in Ultrasonic Backscattered Energy for Temperature Imaging: Factors Affecting Temperature Accuracy and Spatial Resolution in 3D

Change in Ultrasonic Backscattered Energy for Temperature Imaging: Factors Affecting Temperature Accuracy and Spatial Resolution in 3D Change in Ultrasonic Backscattered Energy for Temperature Imaging: Factors Affecting Temperature Accuracy and Spatial Resolution in 3D R. Martin Arthur 1, Jason W. Trobaugh 1, William L. Straube 2, Yuzheng

More information

A Brief Introduction to Medical Imaging. Outline

A Brief Introduction to Medical Imaging. Outline A Brief Introduction to Medical Imaging Outline General Goals Linear Imaging Systems An Example, The Pin Hole Camera Radiations and Their Interactions with Matter Coherent vs. Incoherent Imaging Length

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Physical Acoustics Session 2pPA: Material Characterization 2pPA10. Frequency-resolved

More information

Correlator I. Basics. Chapter Introduction. 8.2 Digitization Sampling. D. Anish Roshi

Correlator I. Basics. Chapter Introduction. 8.2 Digitization Sampling. D. Anish Roshi Chapter 8 Correlator I. Basics D. Anish Roshi 8.1 Introduction A radio interferometer measures the mutual coherence function of the electric field due to a given source brightness distribution in the sky.

More information

Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound

Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound Paper presented at the IEEE International Ultrasonics Symposium, Prague, Czech Republic, 213: Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound Jacob Bjerring Olesen 1,

More information

Pulse-Code Modulation (PCM) :

Pulse-Code Modulation (PCM) : PCM & DPCM & DM 1 Pulse-Code Modulation (PCM) : In PCM each sample of the signal is quantized to one of the amplitude levels, where B is the number of bits used to represent each sample. The rate from

More information

Transducer design simulation using finite element method

Transducer design simulation using finite element method Transducer design simulation using finite element method Wenwu Cao Whitaker Center for Medical Ultrasonic Transducer Engineering Department of Mathematics and Materials Research Laboratory The Pennsylvania

More information

ULTRASONIC INSPECTION, MATERIAL NOISE AND. Mehmet Bilgen and James H. Center for NDE Iowa State University Ames, IA 50011

ULTRASONIC INSPECTION, MATERIAL NOISE AND. Mehmet Bilgen and James H. Center for NDE Iowa State University Ames, IA 50011 ULTRASONIC INSPECTION, MATERIAL NOISE AND SURFACE ROUGHNESS Mehmet Bilgen and James H. Center for NDE Iowa State University Ames, IA 511 Rose Peter B. Nagy Department of Welding Engineering Ohio State

More information

IMAGING THE MECHANICAL PROPERTIES OF TISSUE WITH ULTRASOUND: AN INVESTIGATION OF THE RESPONSE OF SOFT TISSUE TO ACOUSTIC RADIATION FORCE

IMAGING THE MECHANICAL PROPERTIES OF TISSUE WITH ULTRASOUND: AN INVESTIGATION OF THE RESPONSE OF SOFT TISSUE TO ACOUSTIC RADIATION FORCE IMAGING THE MECHANICAL PROPERTIES OF TISSUE WITH ULTRASOUND: AN INVESTIGATION OF THE RESPONSE OF SOFT TISSUE TO ACOUSTIC RADIATION FORCE by Mark L. Palmeri Department of Biomedical Engineering Duke University

More information

A new estimator for vector velocity estimation [medical ultrasonics]

A new estimator for vector velocity estimation [medical ultrasonics] Downloaded from orbit.dtu.dk on: Dec 08, 2018 A new estimator for vector velocity estimation [medical ultrasonics] Jensen, Jørgen Arendt Published in: I E E E Transactions on Ultrasonics, Ferroelectrics

More information

Structure of Biological Materials

Structure of Biological Materials ELEC ENG 3BA3: Structure of Biological Materials Notes for Lecture #19 Monday, November 22, 2010 6.5 Nuclear medicine imaging Nuclear imaging produces images of the distribution of radiopharmaceuticals

More information