Advanced General Aviation Transport Experiments

Size: px
Start display at page:

Download "Advanced General Aviation Transport Experiments"

Transcription

1 Advanced General Aviation Transport Experiments Impact of Aircraft Operation on Composite Airframe Temperatures AGATE-WP October 21 L. Scott Miller, Ph.D. Department of Aerospace Engineering National Institute for Aviation Research Wichita State University Wichita, KS 6726

2 ABSTRACT General Aviation (GA) aircraft airframe temperatures can reach extreme levels while parked on the ground, depending on ambient conditions (e.g., temperature and solar radiation) and airframe construction (e.g., material types, geometry, and paint color). The implications of this situation are extremely important to understand since composite aircraft structural limits are highly dependent on the airframe temperatures. Interestingly, aircraft operation (e.g., taxi, take-off, and climb) can have a favorable impact on strength, as a result of convective heat transfer or cooling. The THERMOD computer code, developed by Govindarajoo, predicts both steady state and transient airframe temperatures based on a comprehensive range of factors, including those mentioned above. Unfortunately, however, the THERMOD program has not been fully validated. Investigation objectives included experimentally measuring the impact of convective cooling and comparing the results to those predicted by the THERMOD code. Five simple, yet representative, composite test components were constructed and evaluated in wind tunnel tests. Temperature and flow speed time histories were recorded for each article. Based on the cases examined, results suggest that the boundary layer character has a noticeable (yet small) impact on the convective cooling, exterior surfaces in direct contact with the flow cool relatively quickly, thermally significant internal components are less affected by convection, and the THERMOD code predictions are conservative. L.S. Miller, Wichita State University, October 21 ii

3 TABLE OF CONTENTS Page 1. Introduction Purpose Background Goals 1 2. Method Basic Approach Test Components Apparatus, Sensors And Procedure 6 3. Results Wind Tunnel Tests THERMOD/Experiment Comparisons Conclusions Acknowledgements References 28 L.S. Miller, Wichita State University, October 21 iii

4 Dimensional Terms NOMENCLATURE L Panel length, along flow direction (Fig. 2 & Table 3) W Panel width, perpendicular to flow direction (Fig. 2 & Table 3) H Beam T-Beam height (Fig. 2 & Table 3) W Beam T-Beam width (Fig. 2 & Table 3) t Panel Panel thickness, top skin, core, and inside skin (Fig. 3 & Table 4) t Mid Total thickness, top skin, core, inside skin, and T-Beam cap (Fig. 3 & Table 4) t Top Top skin thickness (Fig. 3 & Table 4) t Inside Inside skin thickness (Fig. 3 & Table 4) t Beam T-Beam web thickness (Fig. 3 & Table 3) x Traverse station streamwise location, from panel leading edge (Fig. 4 & Table 5) y Traverse spanwise position, from centerline (Fig. 5) z Traverse height location, from bottom edge of T-Beam (Fig. 4 & Table 5) Thermal-Related Terms Ε Approximate emissivity value (Table 5) T Temperature T air Airflow temperature Ti Indicated temperature T Bond Bond line, between T-Beam and panel, temperature j Traverse station or Infrared Sensor number (subscript) L.S. Miller, Wichita State University, October 21 iv

5 LIST OF FIGURES Page Figure 1. Diagram Illustrating Selection Of Test Component Geometry 2 Figure 2. Lower Surface Photographs Of Two Test Panels 4 Figure 3. Diagram Showing Test Panel Dimensional Information 5 Figure 4. Diagram Showing Test Panel Dimensional Information 6 Figure 5. Schematic Diagram And Photograph Of Test Fixture In The Wind Tunnel 7 Figure 6. Front-Corner View Of Fixture In The Wind Tunnel 8 Figure 7. Diagram Showing IR-Sensor Traverse Stations 9 Figure 8. Top-Front View Of Fixture And Installed Test Panel 9 Figure 9. Fixture Interior And Traverse Arms 1 Figure 1. Example Of Panel IR-Sensor Temperature Survey 11 Figure 11. Example Of Experimental Data, Showing Temperature And Flow Time Histories 14 Figure 12. Carbon 1 Experiment And THERMOD Time History Comparisons (Panel Center) 16 Figure 13. Carbon 2 Experiment And THERMOD Time History Comparisons (Panel Center) 17 Figure 14. Glass/Foam Experiment And THERMOD Time History Comparisons (Panel Center) 18 Figure 15. Thin Carbon Experiment And THERMOD Time History Comparisons (Panel Center) 19 Figure 16. Glass/Nomex Experiment And THERMOD Time History Comparisons (Panel Center) 2 Figure 17. Carbon 1 Experiment And THERMOD Time History Comparisons (Away From T-Beam) 22 Figure 18. Carbon 2 Experiment And THERMOD Time History Comparisons (Away From T-Beam) 23 Figure 19. Glass/Foam Experiment And THERMOD Time History Comparisons (Away From T-Beam) 24 Figure 2. Thin Carbon Experiment And THERMOD Time History Comparisons (Away From T-Beam) 25 Figure 21. Glass/Nomex Experiment And THERMOD Time History Comparisons (Away From T-Beam) 26

6 LIST OF TABLES Page Table 1. Sandwich Panel Compositions 3 Table 2. T-Beam Compositions 3 Table 3. Panel And T-Beam Dimensions 4 Table 4. Panel And T-Beam Thickness 5 Table 5. Panel And T-Beam Temperature Deviations 12 Table 6. Panel And T-Beam Approximate Emissivity Values And Traverse Station Locations 12 L.S. Miller, Wichita State University, October 21 vi

7 1. INTRODUCTION 1.1 PURPOSE. A series of wind tunnel experiments were undertaken to identify convective cooling effects on representative aircraft composite airframe components. This report's specific intent is to describe the experimental investigation, document results, and provide a comparison of measured data with computer code predictions. 1.2 BACKGROUND. General Aviation (GA) aircraft airframe temperatures can reach extreme levels while parked on the ground, due to solar radiation and extreme ambient conditions. The implications of this situation are extremely important to understand since composite aircraft structural limits are highly dependent on temperature. Put simply, a very hot and thermally soaked composite airplane is potentially weaker. Unfortunately, it is commonly assumed that there is minimal airframe cooling prior to application of the highest expected air loads during flight. Any effect or tool that might reduce airframe temperatures or more accurately predict the true values offers the potential for aircraft weight, strength and capability improvements. Resultant airplane temperatures depend on a range of factors. For example, ambient weather conditions (e.g., temperature, solar radiation and reflections, and wind velocity), airframe composition, and construction (e.g., material types, geometry, windows, and paint color) all contribute to actual airframe temperatures and strength. As was mentioned before, any type of airframe cooling can have an obvious positive effect. Aircraft operation, for example, during taxi, take-off, and climb can have a favorable impact on strength, as a result of convective heat transfer or cooling. The THERMOD computer code, developed by Govindarajoo, predicts airframe temperatures based on a comprehensive range of factors, including those mentioned previously. 1 Both steady state and transient airframe temperature distributions are predicted. Unfortunately, however, the THERMOD program has not been fully validated. High confidence results from this and other analysis tools (e.g., NASTRAN) are necessary to assure that composite airframe designs are both safe and not over- or under-designed. 1.3 GOALS. The specific investigation goals were to: a. Conduct wind tunnel tests on representative composite airframe components subjected to potentially favorable convective cooling, as is typically experienced during aircraft operations. b. Present, for computer code validation purposes, initial conditions and temperature and wind-speed time-histories for each component. L.S. Miller, Wichita State University, October 21 1

8 c. Compare experimental and computer code results. d. Identify any other factors that notably influence thermal cooling effects and develop recommendations for follow-on efforts. 2.1 BASIC APPROACH. 2. METHOD Five wind tunnel models, built using various representative composite materials and construction methods, were heated until thermal equilibrium was established. The models were placed in a low-speed wind tunnel and the flow was initiated. Temperatures, at various locations, and wind tunnel flow conditions were then measured for a suitable time period as the models cooled. 2.2 TEST COMPONENTS. Prior to conducting the experiments, it was necessary to define a test component composition and geometry. A number of requirements and constraints were considered, including the following. a) Five different components of representative composite materials, construction, and sizes were desired. b) Each component had to be reasonably easy to build and install in the wind tunnel. c) The geometry must be relatively easy to define, for code validation purposes, and be representative of a typical aircraft structural element. Considering these factors a wing-like component was selected for construction and testing, as is illustrated in Figure 1. The test component is essentially a square sandwich panel with a "T- Beam" bonded along the centerline of one side, hence resembling a portion of a wing's skin and spar structure. Wing Panel T-Beam L.S. Miller, Wichita State University, October 21 2

9 FIGURE 1. DIAGRAM ILLUSTRATING SELECTION OF TEST COMPONENT GEOMETRY The panels and T-Beams were constructed, in the Wichita State University (WSU) composites laboratory, using materials and methods common to the aircraft industry. Tables 1 and 2 summarize the composition of each test component and Figure 2 shows photographs of two components. Henceforth, for brevity and simplicity, the entire component (i.e., sandwich panel and T-beam) will be referred to as a panel. Important dimensions are given in Tables 3 and 4, with Figures 3 through 4 identifying associated nomenclature. TABLE 1. SANDWICH PANEL COMPOSITIONS Panel Plys Fabric/Matrix Core Carbon 1 4 3K7P/E765 3/8" Honeycomb Carbon 2 2 3K7P/E765 3/8" Honeycomb Glass/Foam /NB321 3/8" Divinycell Thin Carbon 6 3K7P/E765 none Glass/Nomex /NB321 3/8" Honeycomb TABLE 2. T-BEAM COMPOSITIONS T-Beam Plys Fabric/Matrix Carbon K7P/E765 Carbon K7P/E765 Glass/Foam /NB321 Thin Carbon 14 3K7P/E765 Glass/Nomex /NB321 L.S. Miller, Wichita State University, October 21 3

10 FIGURE 2. LOWER SURFACE PHOTOGRAPHS OF TWO TEST PANELS (NOTE BOND- LINE THERMOCOUPLE CONNECTORS AND WIRES) TABLE 3. PANEL AND T-BEAM DIMENSIONS Panel L W H Beam W Beam t Beam Carbon " " 2.9" 2.54".124" (±.313") (±.313") (±.395") (±.395") (±.2") Carbon " 18." 2.2" 2.465".1256" (±.313") (±.313") (±.395") (±.395") (±.2") Glass/Foam " 18." 2.6" 2.525".117" (±.69") (±.313") (±.395") (±.395") (±.2") Thin Carbon 18." " 2.13") 2.545".128" (±.313") (±.313") (±.395") (±.395") (±.2") Glass/Nomex " 18." 2.85" 2.51".1125") (±.313") (±.313") (±.395") (±.395") (±.2") L.S. Miller, Wichita State University, October 21 4

11 TABLE 4. PANEL AND T-BEAM THICKNESS Panel t Panel t Mid t Top t Inside t Beam Carbon ".5371".398".465".124" (±.34") (±.14") (±.93") (±.86") (±.68") Carbon 2.46".5111".288".378".1256" (±.35") (±.13") (±.57") (±.117") (±.9") Glass/Foam.3829".4745".184".192".117" (±.69") (±.39") (±.18") (±.24") (±.66") Thin Carbon.52".1616" " (±.9") (±.17") - - (±.45") Glass/Nomex.3993".54".38".298".1125" (±.14") (±.21") (±.38") (±.33") (±.28") Flow W L H Beam W Beam L.S. Miller, Wichita State University, October 21 5

12 Flow FIGURE 3. DIAGRAM SHOWING TEST PANEL DIMENSIONAL INFORMATION t Panel t Mid t Top t Inside t Beam FIGURE 4. DIAGRAM SHOWING TEST PANEL DIMENSIONAL INFORMATION 2.3 APPARATUS, SENSORS AND PROCEDURE. A simple oven was used to heat each panel to about 8 C prior to testing. Once thermal equilibrium was obtained, the component was placed in an insulated box for transport to the wind tunnel. The panel was then quickly installed into a specialized fixture located in the wind tunnel test section and then the test began. An open return low-speed wind tunnel, with a 1.X1.3-meter test section, was utilized for all testing. After panel installation, data acquisition began and airflow speed was quickly ramped up to a value of about 35 m/s. Because it is an open return tunnel, air temperature was not controllable and varied with outside (i.e., atmospheric) weather conditions. The wind tunnel fixture, or cradle, served three prime functions. First, it provided an aerodynamic shape to hold the panel for testing. Second, it thermally isolated the test panel from the surroundings on all sides except one, which was intentionally exposed to the wind tunnel flow. Third, the cradle supported and enclosed measurement instrumentation and sensors. A schematic diagram and photograph of the fixture is shown in Figure 5. L.S. Miller, Wichita State University, October 21 6

13 Sensor Traverse Arm Leading-Edge Trailing-Edge Flow Panel Traverse Slot Internal Sensor Arm Wind Tunnel Test Fixture FIGURE 5. SCHEMATIC DIAGRAM AND PHOTOGRAPH OF TEST FIXTURE IN THE WIND TUNNEL L.S. Miller, Wichita State University, October 21 7

14 X 1 & 4 As is shown in Figure 6, each panel fits flush within the sharp leading-edge flat plate upper surface of the fixture, thus creating a simple aerodynamic surface for testing. The cradle interior was thermally insulated and made as airtight as possible. A thin layer of felt (~3.175 mm thick) served as an insulator and gasket to minimize heat conduction or air leakage around the panel edges. A strip of cellophane tape further sealed the gap and the panel into the cradle. A traversing mechanism, mounted within the fixture, continuously oscillated six Infrared (IR) temperature sensors back-and-forth in the spanwise direction (see Figures 5-9). Measurements from these sensors, along with sensor position, defined three interior and three exterior temperature profiles. In addition to the IR-sensors, a thermocouple provided temperature data at the bond-line (between the panel and the T-Beam) inside each panel. Figure 7 identifies the location of each temperature profile. IR-sensors offer a flexible means to measure temperatures without direct contact. This ability was particularly attractive since it greatly simplified component construction and measurement capabilities. Each sensor (Cole-Parmer, P ), with an adjustable emissivity capability, utilizes a 1:1 distance-to-target-size ratio lens. As a result, given the sensor distance was about cm away from the surface, the measured temperature represented the spatial average over about a cm area. The variable emissivity feature proved valuable since it offered a means to both assure measurement accuracy and to identify each panel s emissivity value (needed input data for the THERMOD computer code). Fixture Wind Tunnel FIGURE 6. FRONT-CORNER VIEW OF FIXTURE IN THE WIND TUNNEL X 3 & 6 Impact Xof 2 Aircraft & 5 Operation on Composite Airframe Temperatures L.S. Miller, Wichita State University, October 21 8

15 FIGURE 7. DIAGRAM SHOWING IR-SENSOR TRAVERSE STATIONS Panel Traverse Fixture Leading-Edge FIGURE 8. TOP-FRONT VIEW OF FIXTURE AND INSTALLED TEST PANEL L.S. Miller, Wichita State University, October 21 9

16 FIGURE 9. FIXTURE INTERIOR AND TRAVERSE ARMS Prior to wind tunnel testing simple calibration surveys were performed, with each panel in thermal equilibrium. In each case, the signal conditioning electronics emissivity jumper was adjusted until the IR-sensor temperature readings matched the panel temperature as measured by a thermocouple. This activity served the functions of properly adjusting the IR-sensors and, simultaneously, identifying panel emissivity values. Figure 1 shows sample temperature surveys for one panel and all six sensors. Small variations are observed, despite the fact that the panel temperature is assumed constant everywhere. However, these differences appear reasonable and are likely explained given IR-sensor accuracy limitations (published as ± 2 C), natural deviations in the panel emissivities, and potentially real surface temperature variations. Table 5 summarizes the calibration survey results and gives a measure of the temperature measurement differences and uncertainties. Table 6 identifies the emissivity values and traverse locations for each test panel. Simple thermocouple sensors were utilized to measure the temperature within each panel and in the approaching airstream. As previously mentioned, a single thermocouple was installed during construction within each component on the bond-line between the panel bottom and the T-beam. Data from the traverse position encoder, IR-sensors, the bond-line thermocouple, an airflow thermocouple, and the wind tunnel airspeed system were continuously measured and recorded by a digital data acquisition system (DataQ DI Bit, 8-Channel Analog-to-Digital converter and a PC running WinDaq software). Data was archived to a hard disk and CD-ROM. L.S. Miller, Wichita State University, October 21 1

17 Temperature - degrees C Carbon 2 Panel Temperature Uncertainties No Heat or Flow Miller/WSU, 21 Internal - Front Internal - Middle Internal - Aft External - Front External - Middle External - Aft T-Beam Bond-Line Spanwise Position - cm FIGURE 1. EXAMPLE OF PANEL IR-SENSOR TEMPERATURE SURVEY L.S. Miller, Wichita State University, October 21 11

18 TABLE 5. PANEL AND T-BEAM TEMPERATURE DEVIATIONS Panel T air T Bond Ti 1 Ti 2 Ti 3 Ti 4 Ti 5 Ti 6 (Inside-Frt) (Beam) (Inside-Aft) (Top-Frt) (Top-Mid) (Top-Aft) Carbon C C 19.2 C C C C C C (±.89) (±.82) (±.39) (±.61) (±.17) (±.61) (±.35) (±.22) Carbon C 2.19 C C C C C 2.52 C 2.68 C (± 1.16) (±.97) (±.35) (±.35) (±.36) (±.5) (±.34) (±.34) Glass/Foam 23.4 C C C 2.8 C C 19.7 C C C (±.91) (±.85) (±.19) (±.36) (±.17) (±.4) (±.14) (±.15) Thin Carbon C 2.38 C C C C C 2.45 C 2.61 C (± 1.11) (± 1.) (±.24) (±.67) (±.15) (±.45) (±.22) (±.16) Glass/Nomex C C C C C 2.6 C 23.6 C 23.4 C (±.98) (±.85) (±.26) (±.25) (±.16) (±.46) (±.18) (±.17) TABLE 6. PANEL AND T-BEAM APPROXIMATE EMISSIVITY VALUES AND TRAVERSE STATION LOCATIONS Panel Ε Top Ε Inside Ε Beam x 1 & 4 x 2 & 5 x 3 & 6 z 2 Carbon " " " 1.152" (±.313") (±.313") (±.313") (±.395") Carbon " 9." 15.5" 1.82" (±.313") (±.313") (±.313") (±.395") Glass/Foam " " " 1.152" (±.313") (±.313") (±.313") (±.395") Thin Carbon " 9." 15.5" 1.82" (±.313") (±.313") (±.313") (±.395") Glass/Nomex " " " 1.147" (±.313") (±.313") (±.313") (±.395") 3. RESULTS L.S. Miller, Wichita State University, October 21 12

19 3.1 WIND TUNNEL TESTS. Experimental efforts fell into essentially three categories: calibration tests, wind-off, and wind-on runs. Each panel was run multiple times in each category and thousands of measurements were obtained as a function of time and location. The calibration tests included flow visualization, boundary layer characterization, and IR-sensor and panel calibration runs. Tufts (small yarn strings) were mounted on the test fixture to verify that no separated flow was present. In addition, an acoustic boundary layer probe was used to survey the fixture and panel to identify the boundary layer condition. These tests determined that the flow was turbulent over the panel, with transition typically occurring a short distance upstream. The IR-sensor calibration and panel emissivity identification results were discussed and presented in a previous section. Wind-off tunnel runs were performed to identify natural heat convection effects and to ascertain if heat conduction from the panels into the test fixture was occurring. Wind-on runs obviously focused on determining forced convection effects. Minimal temperature differences between the panel centerline and outboard portions were observed during tests, suggesting that there was minimal heat conduction occurring between the panel and test fixture. In light of these results, data presented in the following sections are for centerline locations only. Figure 11 illustrates some wind-on results for the Carbon 1 panel. Wind tunnel speed and IRsensor temperature time histories, for three exterior and three interior locations and the T-Beam bond-line, are shown. Results for the other panels parallel this data in basic trends and will be shown later in direct comparisons with THERMOD computer code predictions. Some basic experimental observations deserve note. The panel exterior cools more quickly than the interior, as one might expect given the airflow effects and the insulated fixture used to hold the panel. Also shown in Figure 11, the T-Beam represents a considerable thermal mass and it takes the longest to cool. In addition, as is classically associated with boundary layer flow development and convective heat transfer, the front panel stations consistently cool slightly more than the downstream portions. It is important to note, final exterior temperatures converge to below zero degrees for the specific case shown in Figure 11. These temperatures are within the expected sensor accuracy and properly reflect the weather conditions on the day the Carbon 1 panel was tested. However, they are at the published minimum acceptable sensor operating conditions. Simple testing showed that the sensors become slightly under-damped when exposed to sudden temperature changes at such low ambient conditions, as was the case when the tunnel started under these circumstances. The IR-sensors did behave properly as the run progressed. Fortunately, this is the only panel that was subjected to such atmospheric temperature extremes (the weather got better). L.S. Miller, Wichita State University, October 21 13

20 Temperature - degrees C Carbon 1 Temperature & Velocity Time History Longitudinal Center-Line Miller/WSU, 21 Internal - Front Internal - Middle Internal - Aft External - Front External - Middle External - Aft Airspeed T-Beam Bond-Line Airspeed - m/s 1 Flow FIGURE 11. EXAMPLE OF EXPERIMENTAL DATA, SHOWING TEMPERATURE AND FLOW TIME HISTORIES 3.2 THERMOD/EXPERIMENT COMPARISONS. Panel composition, geometry, emissivity, and other critical information (shown in previous tables and figures in this report) and environmental conditions were supplied to the THERMOD computer code developer, Renganathan Govindarajoo. Only the first 6 seconds of actual experimental results were provided, so as not to bias code predictions. He generated thermal behavior predictions for direct comparison to the experimental data. Specific information on the THERMOD input parameters, assumptions, and other related information is included in a separate report prepared by Govindarajoo 2. L.S. Miller, Wichita State University, October 21 14

21 Figures illustrate some comparisons between THERMOD predictions and experimental measurements for all five test components during wind-off and wind-on conditions. These specific results are at a location near the panel center on the exterior and at the T-Beam bondline location. Some basic and universal differences surface in these plots. Specifically, THERMOD predictions show a slower initial rate of change and higher final temperatures. The variance is most pronounced at the end of wind-off runs with THERMOD predictions showing, respectively, external and T-Beam bond-line temperatures approximately 1-2 C and C higher. Wind-on external and T-Beam bond-line differences are smaller, being respectively 5-1 C and 5-2 C hotter. L.S. Miller, Wichita State University, October 21 15

22 8 Carbon 1 No Flow Temperature Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line 6 Temperature - degrees C Temperature - degrees C Carbon 1 Temperature & Velocity Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External 5 Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Airspeed Airspeed - m/s FIGURE 12. CARBON 1 EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (PANEL CENTER) L.S. Miller, Wichita State University, October 21 16

23 Temperature - degrees C Carbon 2 No Flow Temperature Time History THERMOD/Experiment - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Carbon 2 Temperature & Velocity Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Airspeed 5 4 Temperature - degrees C Airspeed - m/s FIGURE 13. CARBON 2 EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (PANEL CENTER) L.S. Miller, Wichita State University, October 21 17

24 8 Glass/Foam No Flow Temperature Time History THERMOD/Experiment - Panel Center Miller/WSU, 21 Experiment External Experiement T-Beam Bond-Line THERMOD T-Beam Bond-Line 6 Temperature - degrees C Glass/Foam Temperature & Velocity Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line 5 THERMOD T-Beam Bond-Line Airspeed Temperature - degrees C Airspeed - m/s FIGURE 14. GLASS/FOAM EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (PANEL CENTER) L.S. Miller, Wichita State University, October 21 18

25 Temperature - degrees C Thin Carbon No Flow Temperature Time History THERMOD/Experiment - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Thin Carbon Temperature & Velocity Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Airspeed 5 4 Temperature - degrees C Airspeed - m/s FIGURE 15. THIN CARBON EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (PANEL CENTER) L.S. Miller, Wichita State University, October 21 19

26 8 Glass/Nomex No Flow Temperature Time History THERMOD/Experiment - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line 6 Temperature - degrees C Glass/Nomex Temperature & Velocity Time History THERMOD/Experiment Comparison - Panel Center Miller/WSU, 21 Experiment External Experiment T-Beam Bond-Line THERMOD T-Beam Bond-Line Airspeed Temperature - degrees C Airspeed - m/s FIGURE 16. GLASS/NOMEX EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (PANEL CENTER) L.S. Miller, Wichita State University, October 21 2

27 Figures illustrate comparisons between THERMOD predictions and experimental measurements for all five test components, during wind-off and wind-on conditions, at locations away from the panel center. Experimental results are for front and aft locations (as shown in Figure 7), whereas the THERMOD modeling and predictions do not differentiate between upstream and downstream locations. Results are similar in many respects to those previously presented and discussed, with the notable exception that final temperature differences, between predictions and experiment, are now reduced and within about 1 C. This important observation underscores that the T-Beam s presence significantly affects the results, in both the experiment and THERMOD modeling. Significant internal, including longitudinal, heat conduction is be expected and should be predicted. L.S. Miller, Wichita State University, October 21 21

28 8 6 Carbon 1 No Flow Temperature Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Temperature - degrees C Temperature - degrees C Carbon 1 Temperature & Velocity Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 Experiment Internal - Front 5 Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft 4 Airspeed Airspeed - m/s FIGURE 17. CARBON 1 EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (AWAY FROM T-BEAM) L.S. Miller, Wichita State University, October 21 22

29 Temperature - degrees C Carbon 2 No Flow Temperature Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Temperature - degrees C Carbon 2 Temperature & Velocity Time History THERMOD/Experiment Comparison - Away From T-Beam 5 Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Airspeed Airspeed - m/s FIGURE 18. CARBON 2 EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (AWAY FROM T-BEAM) L.S. Miller, Wichita State University, October 21 23

30 Glass/Foam No Flow Temperature Time History THERMOD/Experiment Comparison - Away From T-Beam 8 Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Temperature - degrees C Glass/Foam Temperature & Velocity Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 6 Temperature - degrees C 5 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Airspeed Airspeed - m/s FIGURE 19. GLASS/FOAM EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (AWAY FROM T-BEAM) L.S. Miller, Wichita State University, October 21 24

31 Temperature - degrees C Thin Carbon No Flow Temperature Time History THERMOD/Experiment Comparison - Away From the T-Beam Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Temperature - degrees C Thin Carbon Temperature & Velocity Time History THERMOD/Experiment Comparison - Away From T-Beam 5 Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Airspeed Airspeed - m/s FIGURE 2. THIN CARBON EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (AWAY FROM T-BEAM) L.S. Miller, Wichita State University, October 21 25

32 Temperature - degrees C Glass/Nomex No Flow Temperature Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Temperature - degrees C Glass/Nomex Temperature & Velocity Time History THERMOD/Experiment Comparison - Away From T-Beam Miller/WSU, 21 Experiment Internal - Front Experiment Internal - Aft THERMOD Internal Experiment External - Front Experiment External - Aft Airspeed Airspeed - m/s FIGURE 21. GLASS/NOMEX EXPERIMENT AND THERMOD TIME HISTORY COMPARISONS (AWAY FROM T-BEAM) 4. CONCLUSIONS L.S. Miller, Wichita State University, October 21 26

33 Based on the experiment results, the following conclusions are offered. 1. Aircraft exterior skins can be expected to cool relatively quickly as they begin operations and convective cooling takes place. Some internal components, like a large heavy spar or wellinsulated structure, can experience a notable delay in cooling. 2. Boundary layer condition and development, which is not modeled in the THERMOD computer code, is observed to have a slight effect on the cooling rate in the downstream direction. 3. The THERMOD computer code predictions tend, for the cases examined, to capture fundamental trends very well. However, the results appear to show slower cooling rates and higher final temperatures. Most significantly, the predictions are conservative (favoring safety). 4. The discrepancy between experiment and THERMOD code results appears to depend on the corresponding structural complexity, specifically that associated with the T-Beam s presence. Differences as low as 1 C and as high as 25 C were observed for, respectively, simple (i.e., skins and core) and more complex (i.e., skins, core, and T-Beam) portions of the test panels. These observations suggest that internal conduction may play a critical role in distributing heat in the longitudinal directions. 5. The current investigation was intentionally limited to and focused on convective cooling effects. Additional tests examining the impact of other factors that influence both airframe heating and cooling are warranted. 5. ACKNOWLEDGEMENTS A number of people participated in this project and deserve special recognition and thanks. Over the years Donald Oplinger, Peter Shyprykevich, and Larry Ilcewicz from the Federal Aviation Administration (FAA) provided significant project support, guidance, feedback, and help. In addition, special gratitude goes to NASA/AGATE and specifically Steve Hooper and John Tomblin who supplied support, insight, and advice that was critical, timely, and most appreciated. I must also note the hard work and efforts of various Wichita State University (WSU) students that participated in the project. Mike Murdin (now with Boeing), James Waltner, Tejas Mazmudar (7), Monal Merchant, and Yeow Ng excelled and played a critical role. Without everyone s contributions the project would have never happened or been completed. Thank you all very much. 6. REFERENCES L.S. Miller, Wichita State University, October 21 27

34 1. Govindarajoo, Renganathan, "THERMOD: A Thermal Model for Predicting Aircraft MOL Temperatures," Report No. REK2A.DOC, Cirrus Design Corporation, Duluth, MN, October, Govindarajoo, Renganathan, "A Thermal Model (THERMOD) for Simulating Maximum Operating Limit Temperatures of Aircraft (Revision)," publication pending. L.S. Miller, Wichita State University, October 21 28

Infrared Thermometer Calibration A Complete Guide

Infrared Thermometer Calibration A Complete Guide Infrared Thermometer Calibration A Complete Guide Application note With proper setup and planning, infrared calibrations can be accurate. The steps outlined below should be followed to perform accurate

More information

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06 ALL SEASONS DOOR & WINDOW, INC. Report No: NCTL-110-8058-5S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06 Test Specimen NFRC Code Manufacturer : All Seasons Door & Window, Inc. Series/Model

More information

Experimental Aerodynamics. Experimental Aerodynamics

Experimental Aerodynamics. Experimental Aerodynamics Lecture 3: Vortex shedding and buffeting G. Dimitriadis Buffeting! All structures exposed to a wind have the tendency to vibrate.! These vibrations are normally of small amplitude and have stochastic character!

More information

Standard Practices for Air Speed Calibration Testing

Standard Practices for Air Speed Calibration Testing Standard Practices for Air Speed Calibration Testing Rachael V. Coquilla Bryza Wind Lab, Fairfield, California Air speed calibration is a test process where the output from a wind measuring instrument

More information

EXPERIMENTS OF CLOSED-LOOP FLOW CONTROL FOR LAMINAR BOUNDARY LAYERS

EXPERIMENTS OF CLOSED-LOOP FLOW CONTROL FOR LAMINAR BOUNDARY LAYERS Fourth International Symposium on Physics of Fluids (ISPF4) International Journal of Modern Physics: Conference Series Vol. 19 (212) 242 249 World Scientific Publishing Company DOI: 1.1142/S211945128811

More information

SPC Aerodynamics Course Assignment Due Date Monday 28 May 2018 at 11:30

SPC Aerodynamics Course Assignment Due Date Monday 28 May 2018 at 11:30 SPC 307 - Aerodynamics Course Assignment Due Date Monday 28 May 2018 at 11:30 1. The maximum velocity at which an aircraft can cruise occurs when the thrust available with the engines operating with the

More information

Thermal modelling of the Wing Anti Ice System in modern aircrafts

Thermal modelling of the Wing Anti Ice System in modern aircrafts Advanced Computational Methods and Experiments in Heat Transfer XII 305 Thermal modelling of the Wing Anti Ice System in modern aircrafts D. Labuhn 1 & M. Logeais 2 1 Thermal Technology Centre, Airbus,

More information

International Conference on Methods of Aerophysical Research, ICMAR 2008

International Conference on Methods of Aerophysical Research, ICMAR 2008 International Conference on Methods of Aerophysical Research, ICMAR 8 EXPERIMENTAL STUDY OF UNSTEADY EFFECTS IN SHOCK WAVE / TURBULENT BOUNDARY LAYER INTERACTION P.A. Polivanov, А.А. Sidorenko, A.A. Maslov

More information

Aircraft Icing FAR/CS-25, Appendix O and P charts

Aircraft Icing FAR/CS-25, Appendix O and P charts Aircraft Icing FAR/CS-25, Appendix O and P charts Prof. Dr. Serkan ÖZGEN Dept. Aerospace Engineering, METU Fall 2015 Outline Appendix O and P - Background Existing CS-25 certification specifications for

More information

NATIONAL TRANSPORTATION SAFETY BOARD WASHINGTON, D.C.

NATIONAL TRANSPORTATION SAFETY BOARD WASHINGTON, D.C. DOCKET NO. SA-516 EXHIBIT NO. 22A NATIONAL TRANSPORTATION SAFETY BOARD WASHINGTON, D.C. TRAJECTORY STUDY (16 Pages) NATIONAL TRANSPORTATION SAFETY BOARD Office of Research and Engineering Washington, DC

More information

In-Flight Mixed Phase Ice Accretion Prediction on Finite Wings with TAICE-3D

In-Flight Mixed Phase Ice Accretion Prediction on Finite Wings with TAICE-3D 7 TH EUROPEAN CONFERENCE FOR AERONAUTICS AND AEROSPACE SCIENCES (EUCASS) DOI: 339 In-Flight Mixed Phase Ice Accretion Prediction on Finite Wings with TAICE-3D Erdem Ayan and Serkan Özgen Turkish Aerospace

More information

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: , ICAER 2011 AN EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF HEAT LOSSES FROM THE CAVITY RECEIVER USED IN LINEAR FRESNEL REFLECTOR SOLAR THERMAL SYSTEM Sudhansu S. Sahoo* a, Shinu M. Varghese b, Ashwin

More information

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen * This is not the original copy of the test report if you would like an original copy, please contact our East Brunswick office or the NCTL to request a copy. ALL SEASONS DOOR & WINDOW, INC. REPORT NO:

More information

High performance DC link capacitor/bus sourcing dual Infineon HybridPACK TM Drive inverters for EV applications

High performance DC link capacitor/bus sourcing dual Infineon HybridPACK TM Drive inverters for EV applications High performance DC link capacitor/bus sourcing dual Infineon HybridPACK TM Drive inverters for EV applications Michael A. Brubaker, SBE Inc., USA, MichaelB@sbelectronics.com Terry A. Hosking, SBE Inc.,

More information

The Ice Crystal Weather Threat to Engines

The Ice Crystal Weather Threat to Engines Jeanne Mason Boeing Commercial Airplanes The Ice Crystal Weather Threat to Engines BOEING is a trademark of Boeing Management Company. Filename.ppt 1 Agenda Introduction Recognition of engine power-loss

More information

A Demonstration Unit to Enhance Heat Transfer Lectures on Natural and Forced Convection

A Demonstration Unit to Enhance Heat Transfer Lectures on Natural and Forced Convection A Demonstration Unit to Enhance Heat Transfer Lectures on Natural and Forced Convection Charles H. Forsberg Department of Engineering, Hofstra University, Hempstead, NY 11549 Session 1566 Overview As a

More information

ASSET INTEGRITY INTELLIGENCE. Featured Article. ACHIEVING A COMPREHENSIVE FIRED HEATER HEALTH MONITORING PROGRAM By Tim Hill, Quest Integrity Group

ASSET INTEGRITY INTELLIGENCE. Featured Article. ACHIEVING A COMPREHENSIVE FIRED HEATER HEALTH MONITORING PROGRAM By Tim Hill, Quest Integrity Group ASSET INTEGRITY INTELLIGENCE Featured Article ACHIEVING A COMPREHENSIVE FIRED HEATER HEALTH MONITORING PROGRAM By Tim Hill, Quest Integrity Group VOLUME 20, ISSUE 5 SEPTEMBER OCTOBER 2014 ACHIEVING A COMPREHENSIVE

More information

MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011

MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011 MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011 CONVECTIVE HEAT TRANSFER COEFFICIENT IN COMPARTMENT FIRES J. G. Qunitiere* and P. S. Veloo** jimq@umd.edu *University of Maryland, College

More information

Relaminerization of a Highly Accelerated Flow on a Convex Curvature

Relaminerization of a Highly Accelerated Flow on a Convex Curvature Relaminerization of a Highly Accelerated Flow on a Convex Curvature Abstract Relaminarization of turbulent flow is a process by which the mean flow reverts to an effectively laminar state. The phenomenon

More information

A FLIGHT TEST EVALUATION OF THE SINHA WING PERFORMANCE ENHANCING DETURBULATORS Richard H. Johnson 1/2/07

A FLIGHT TEST EVALUATION OF THE SINHA WING PERFORMANCE ENHANCING DETURBULATORS Richard H. Johnson 1/2/07 1 A FLIGHT TEST EVALUATION OF THE SINHA WING PERFORMANCE ENHANCING DETURBULATORS Richard H. Johnson 1/2/07 INTRODUCTION It is extremely rare that one has an opportunity to take part in a completely new

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

Full Scale Structural Durability Test Spectrum Reduction by Truncation Coupon Testing

Full Scale Structural Durability Test Spectrum Reduction by Truncation Coupon Testing Full Scale Structural Durability Test Spectrum Reduction by Truncation Coupon Testing Ogewu C. Agbese F-16/F-22 IFG Service Life Analysis Lockheed Martin Aeronautics Fort Worth, TX, USA ogewu.c.agbese@lmco.com

More information

Fig 1. Power Tower during Operation

Fig 1. Power Tower during Operation Accurate Flux Calculations Using Thermographic IR cameras in Concentrated Solar Power Fields A. Eitan*, G. Naor*, R. Hayut*, I. Segev*, J. Golbert**, S. Pekarsky*, A. Zisken*, G. Medan*, A. Feigelstock*,

More information

QIRT th International Conference on Quantitative InfraRed Thermography

QIRT th International Conference on Quantitative InfraRed Thermography 10 th International Conference on Quantitative InfraRed Thermography July 27-30, 2010, Québec (Canada) Quantitative infrared wall inspection *CE Dept., Cracow University of Technology, Kraków, Poland,

More information

Fan Stage Broadband Noise Benchmarking Programme

Fan Stage Broadband Noise Benchmarking Programme Fan Stage Broadband Noise Benchmarking Programme Specification of Fundamental Test Case 3 (FC3) Version 1 : 26 January 2015 Test Case Coordinator John Coupland ISVR University of Southampton UK E-mail

More information

COMPRESSIBLE BOUNDARY LAYER HEAT FLUX MEASUREMENT USING EMBEDDED THERMOCOUPLES

COMPRESSIBLE BOUNDARY LAYER HEAT FLUX MEASUREMENT USING EMBEDDED THERMOCOUPLES COMPRESSIBLE BOUNDARY LAYER HEAT FLUX MEASUREMENT USING EMBEDDED THERMOCOUPLES Zhao xuejun1*, Ma yuanhong**, Xiao weizhong3*** *China Academy of Aerospace Aerodynamics, ** China Academy of Aerospace Aerodynamics,

More information

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar Experiment 1 Measurement of Thermal Conductivity of a Metal (Brass) Bar Introduction: Thermal conductivity is a measure of the ability of a substance to conduct heat, determined by the rate of heat flow

More information

Wind Tunnel Experiments of Stall Flutter with Structural Nonlinearity

Wind Tunnel Experiments of Stall Flutter with Structural Nonlinearity Wind Tunnel Experiments of Stall Flutter with Structural Nonlinearity Ahmad Faris R.Razaami School of Aerospace Engineering, Universiti Sains Malaysia, Penang, MALAYSIA Norizham Abdul Razak School of Aerospace

More information

Momentum (Newton s 2nd Law of Motion)

Momentum (Newton s 2nd Law of Motion) Dr. Nikos J. Mourtos AE 160 / ME 111 Momentum (Newton s nd Law of Motion) Case 3 Airfoil Drag A very important application of Momentum in aerodynamics and hydrodynamics is the calculation of the drag of

More information

Experimental Investigation of Convoluted Contouring for Aircraft Afterbody Drag Reduction

Experimental Investigation of Convoluted Contouring for Aircraft Afterbody Drag Reduction AIAA 99-267 Experimental Investigation of Convoluted Contouring for Aircraft Afterbody Drag Reduction K. A. Deere and C. A. Hunter NASA Langley Research Center Hampton, VA 35th AIAA/ASME/SAE/ASEE Joint

More information

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS Mark Luther 1, Timothy Anderson 2, and Tim Brain 3 1 School of Architecture and Building, Deakin University, Geelong, Australia 2 School

More information

Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography

Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography Vadiraj A. Hemadri 1, Sameer Khandekar 2 1: Dept. of Mechanical Engineering, IIT Kanpur, India, vadiraj@iitk.ac.in

More information

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS THERMAL SCIENCE, Year 2011, Vol. 15, No. 2, pp. 457-465 457 NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS by Vukman V. BAKI] *, Goran S. @IVKOVI], and Milada L. PEZO Laboratory

More information

On the correlation of the acoustic signal of microphones mounted on a flat plate to the turbulence of an impinging jet

On the correlation of the acoustic signal of microphones mounted on a flat plate to the turbulence of an impinging jet On the correlation of the acoustic signal of microphones mounted on a flat plate to the turbulence of an impinging jet C. Reichl a, M. Boeck a, W. Tilser a, H. Lang a, K. Haindl b, F. Reining b and M.

More information

Part 3. Stability and Transition

Part 3. Stability and Transition Part 3 Stability and Transition 281 Overview T. Cebeci 1 Recent interest in the reduction of drag of underwater vehicles and aircraft components has rekindled research in the area of stability and transition.

More information

Given the water behaves as shown above, which direction will the cylinder rotate?

Given the water behaves as shown above, which direction will the cylinder rotate? water stream fixed but free to rotate Given the water behaves as shown above, which direction will the cylinder rotate? ) Clockwise 2) Counter-clockwise 3) Not enough information F y U 0 U F x V=0 V=0

More information

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES SEMI G38-0996 N/A SEMI 1987, 1996 TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES 1 Purpose The purpose of this test is to determine

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC. NFRC 102-2014 THERMAL PERFORMANCE TEST REPORT Rendered to: NORTH EAST WINDOWS USA, INC. SERIES/MODEL: 100 Double Hung TYPE: Vertical Slider (Double Hung) Summary of Results Standardized Thermal Transmittance

More information

Convection heat transfer coefficients for axial flow gas quenching of a cylinder

Convection heat transfer coefficients for axial flow gas quenching of a cylinder Proceedings of the Fourth International Conference on Quenching and the Control of Distortion, 2-23 May, 23, Beijing Convection heat transfer coefficients for axial flow gas quenching of a cylinder Roland

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

Dynamic Response of an Aircraft to Atmospheric Turbulence Cissy Thomas Civil Engineering Dept, M.G university

Dynamic Response of an Aircraft to Atmospheric Turbulence Cissy Thomas Civil Engineering Dept, M.G university Dynamic Response of an Aircraft to Atmospheric Turbulence Cissy Thomas Civil Engineering Dept, M.G university cissyvp@gmail.com Jancy Rose K Scientist/Engineer,VSSC, Thiruvananthapuram, India R Neetha

More information

Aeroelasticity. Lecture 4: Flight Flutter Testing. G. Dimitriadis. AERO0032-1, Aeroelasticity and Experimental Aerodynamics, Lecture 4

Aeroelasticity. Lecture 4: Flight Flutter Testing. G. Dimitriadis. AERO0032-1, Aeroelasticity and Experimental Aerodynamics, Lecture 4 Aeroelasticity Lecture 4: Flight Flutter Testing G. Dimitriadis AERO0032-1, Aeroelasticity and Experimental Aerodynamics, Lecture 4 1 Main reference A Historical Overview of Flight Flutter Testing, Michael

More information

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND Collins, M.R., and Harrison, S.J., "The Effects of Calorimeter Tilt on the Inward-Flowing Fraction of Absorbed Solar Radiation in a Venetian Blind", ASHRAE Transactions, Vol. 107 (1), pp. 677-683, 2001.

More information

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Emissivity: Understanding the difference between apparent and actual infrared temperatures Emissivity: Understanding the difference between apparent and actual infrared temperatures By L. Terry Clausing, P.E. ASNT Certified NDT Level III T/IR, for Fluke Corporation Application Note Taking infrared

More information

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006 ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006 version May 23, 2006 1 Objective The objective of the laboratory exercise is to measure the convective heat transfer coefficient

More information

SONIC PULSE VELOCITY TESTING TO ASSESS CONDITION OF A CONCRETE DAM

SONIC PULSE VELOCITY TESTING TO ASSESS CONDITION OF A CONCRETE DAM SONIC PULSE VELOCITY TESTING TO ASSESS CONDITION OF A CONCRETE DAM Edward D. Billington, AG&E-Schnabel, Greensboro, NC Dennis A. Sack and Larry D. Olson, Olson Engineering Inc., Wheat Ridge, CO Abstract

More information

2.4 The ASME measurement-uncertainty formulation

2.4 The ASME measurement-uncertainty formulation Friday, May 14, 1999 2.5 Propagation of uncertainty estimates Page: 1 next up previous contents Next: 2.5 Propagation of uncertainty Up: 2. Measurement Uncertainty Previous: 2.3 More terminology 2.4 The

More information

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction CALIFORNIA INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering ME 96 Free and Forced Convection Experiment Revised: 25 April 1994 1. Introduction The term forced convection refers to heat transport

More information

MEASUREMENT OF THE THERMAL DIFFUSIVITY OF BUILDING MATERIALS

MEASUREMENT OF THE THERMAL DIFFUSIVITY OF BUILDING MATERIALS HEAT008 6 th International Conference on Heat Transfer, luid Mechanics and Thermodynamics 30 June to July 008 Pretoria, South Africa Paper number: LC1 MEASUREMENT O THE THERMAL DIUSIVITY O BUILDING MATERIALS

More information

Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method

Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method Speaker: Cecil G. Burkett NASA Langley Research Center Mail Stop 236 Hampton VA 23681 PH: 757-864-4720 FAX:

More information

Stability and Control Some Characteristics of Lifting Surfaces, and Pitch-Moments

Stability and Control Some Characteristics of Lifting Surfaces, and Pitch-Moments Stability and Control Some Characteristics of Lifting Surfaces, and Pitch-Moments The lifting surfaces of a vehicle generally include the wings, the horizontal and vertical tail, and other surfaces such

More information

Week 14 The Simple Pendulum

Week 14 The Simple Pendulum Week 14 The Simple Pendulum 1. Scope 1.1 Goal Conduct experiment to study the simple harmonic motion of an oscillatory pendulum and analyze and interpret the data 1.2 Units of measurement to use United

More information

IGNITABILITY ANALYSIS USING THE CONE CALORIMETER AND LIFT APPARATUS

IGNITABILITY ANALYSIS USING THE CONE CALORIMETER AND LIFT APPARATUS 189 IGNITABILITY ANALYSIS USING THE CONE CALORIMETER AND LIFT APPARATUS Mark A. Dietenberger USDA Forest Service Forest Products Laboratory* Madison, WI 53705-2398 ABSTRACT The irradiance plotted as function

More information

CHAPTER 3 HELIPORT AND HELICOPTER STAGEFIELD LIGHTING SYSTEMS

CHAPTER 3 HELIPORT AND HELICOPTER STAGEFIELD LIGHTING SYSTEMS CHAPTER 3 HELIPORT AND HELICOPTER STAGEFIELD LIGHTING SYSTEMS TM 5-811-5 3-1. General design and layout criteria lights spaced approximately 17 feet on centers. The outera. Heliport runway. Figures 2-1,

More information

Comparing 2-D Conduction Experiments with Simulation

Comparing 2-D Conduction Experiments with Simulation Comparing 2-D Conduction Experiments with Simulation Introduction Simulation techniques are often used in industry as a beneficial part in the development process whether an engineer or scientist is designing

More information

Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar Collectors

Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar Collectors Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2012 Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar

More information

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

MIL-STD-883E METHOD THERMAL CHARACTERISTICS THERMAL CHARACTERISTICS 1. PURPOSE. The purpose of this test is to determine the thermal characteristics of microelectronic devices. This includes junction temperature, thermal resistance, case and mounting

More information

Lecture-4. Flow Past Immersed Bodies

Lecture-4. Flow Past Immersed Bodies Lecture-4 Flow Past Immersed Bodies Learning objectives After completing this lecture, you should be able to: Identify and discuss the features of external flow Explain the fundamental characteristics

More information

Notes on Absorption and Impedance Measurements

Notes on Absorption and Impedance Measurements Notes on Absorption and Impedance Measurements Andrew F. Seybert University of Kentucky Lexington, KY 456-18 859-257-6336 x 8645 seybert@engr.uky.edu Applicable Standards. There are two standards 1,2 for

More information

Experimental characterization of flow field around a square prism with a small triangular prism

Experimental characterization of flow field around a square prism with a small triangular prism Journal of Mechanical Science and Technology 29 (4) (2015) 1649~1656 www.springerlink.com/content/1738-494x OI 10.1007/s12206-015-0336-2 Experimental characterization of flow field around a square prism

More information

Development of a probe traversing system for an open test section wind tunnel

Development of a probe traversing system for an open test section wind tunnel Development of a probe traversing system for an open test section wind tunnel Gépészet 2012 Conference 24 th of May, 2012 Section Energy 2. Árpád Varga Mechanical Engineering Modelling MSc, Contractual

More information

Passive Mitigation of Aero-Induced Mechanical Jitter of Flat-Windowed Turrets

Passive Mitigation of Aero-Induced Mechanical Jitter of Flat-Windowed Turrets 42th AIAA Plasmadynamics and Lasers Conference 27 30 Jun 2011, Honolulu, HI Passive Mitigation of Aero-Induced Mechanical Jitter of Flat-Windowed Turrets Zach B. Ponder 1, Stanislav Gordeyev 2, Eric J.

More information

Calibrating the Thermal Camera

Calibrating the Thermal Camera 1 of 5 4/19/2012 5:33 AM from photonics.com: 12/01/2009 http://www.photonics.com/article.aspx?aid=40679 Calibrating the Thermal Camera As thermal cameras gain ground in the commercial market, testing becomes

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. NFRC 102-2014 THERMAL PERFORMANCE TEST REPORT Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: 45X - High Performance Dual Thermally Broken Storefront TYPE: Glazed Wall Systems (Site-built) Summary of

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Review of Anemometer Calibration Standards

Review of Anemometer Calibration Standards Review of Anemometer Calibration Standards Rachael V. Coquilla rvcoquilla@otechwind.com Otech Engineering, Inc., Davis, CA Anemometer calibration defines a relationship between the measured signals from

More information

Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation

Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation More Info at Open Access Database www.ndt.net/?id=17680 Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation Abstract By S. TAVAKOLI **, *,

More information

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading 1 of 15 JCI 12 October 2001 Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading 1 Introduction This document

More information

Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficients over a Gas Turbine Blade Leading Edge Configuration

Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficients over a Gas Turbine Blade Leading Edge Configuration Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficients over a Gas Turbine Blade Leading Edge Configuration Giridhara Babu Yepuri 1,a, Ashok Babu Talanki Puttarangasetty

More information

Observing Convection in Microgravity. Matt Heer. East Troy High School Physics

Observing Convection in Microgravity. Matt Heer. East Troy High School Physics Observing Convection in Microgravity Matt Heer East Troy High School Physics Abstract. The purpose of the experiment is to observe the movement, or lack thereof, of heat in an enclosed space in multiple

More information

INFLUENCE OF ACOUSTIC EXCITATION ON AIRFOIL PERFORMANCE AT LOW REYNOLDS NUMBERS

INFLUENCE OF ACOUSTIC EXCITATION ON AIRFOIL PERFORMANCE AT LOW REYNOLDS NUMBERS ICAS 2002 CONGRESS INFLUENCE OF ACOUSTIC EXCITATION ON AIRFOIL PERFORMANCE AT LOW REYNOLDS NUMBERS S. Yarusevych*, J.G. Kawall** and P. Sullivan* *Department of Mechanical and Industrial Engineering, University

More information

Task 3 Desired Stakeholder Outcomes

Task 3 Desired Stakeholder Outcomes Task 3 Desired Stakeholder Outcomes Colby Jensen IRP Kickoff Meeting, Nov 19-20, 2015 Instrumentation Overview Three general levels of core instrumentation: Reactor control and operation Additional reactor

More information

ON LINE ARCHIVE OF STORM PENETRATING DATA

ON LINE ARCHIVE OF STORM PENETRATING DATA ON LINE ARCHIVE OF STORM PENETRATING DATA Matthew Beals, Donna V. Kliche, and Andrew G. Detwiler Institute of Atmospheric Sciences, South Dakota School of Mines and Technology, Rapid City, SD Steve Williams

More information

Department of Mechanical Engineering

Department of Mechanical Engineering Department of Mechanical Engineering AMEE401 / AUTO400 Aerodynamics Instructor: Marios M. Fyrillas Email: eng.fm@fit.ac.cy HOMEWORK ASSIGNMENT #2 QUESTION 1 Clearly there are two mechanisms responsible

More information

Aeroelastic Gust Response

Aeroelastic Gust Response Aeroelastic Gust Response Civil Transport Aircraft - xxx Presented By: Fausto Gill Di Vincenzo 04-06-2012 What is Aeroelasticity? Aeroelasticity studies the effect of aerodynamic loads on flexible structures,

More information

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures Peer Reviewed Paper Piratheepan Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures Abstract M Piratheepan 1, T N Anderson 1, S Saiful 1 1 Auckland University of

More information

Nonlinear Finite Element Analysis of Airport Approach Lighting Structures under Impact Loading

Nonlinear Finite Element Analysis of Airport Approach Lighting Structures under Impact Loading 8 th International LS-DYNA Users Conference Simulation Technology (2) Nonlinear Finite Element Analysis of Airport Approach Lighting Structures under Impact Loading M. Nejad Ensan *1, D.G. Zimcik 1, S.T.

More information

Unsteady Volumetric Entropy Generation Rate in Laminar Boundary Layers

Unsteady Volumetric Entropy Generation Rate in Laminar Boundary Layers Entropy 6, 8[], 5-3 5 Entropy ISSN 99-43 www.mdpi.org/entropy/ Unsteady Volumetric Entropy Generation Rate in Laminar Boundary Layers E. J. Walsh & D. Hernon Stokes Research Institute, Dept. of Mechanical

More information

Fluctuating Pressure Inside/Outside the Flow Separation Region in High Speed Flowfield

Fluctuating Pressure Inside/Outside the Flow Separation Region in High Speed Flowfield Journal of Aerospace Science and Technology 1 (2015) 18-26 doi: 10.17265/2332-8258/2015.01.003 D DAVID PUBLISHING Fluctuating Pressure Inside/Outside the Flow Separation Region in High Speed Flowfield

More information

Measurement method for the proficiency testing program

Measurement method for the proficiency testing program APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of

More information

Passive Turbulence Generating Grid Arrangements in a Turbine Cascade Wind Tunnel

Passive Turbulence Generating Grid Arrangements in a Turbine Cascade Wind Tunnel Passive Turbulence Generating Grid Arrangements in a Turbine Cascade Wind Tunnel Connor J. Wiese *, Michael J. McClearn, Giovanni Allevato, and Richard T. Guttman III United States Air Force Academy, USAFA,

More information

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010 Technical Notes Introduction Thermal Management for LEDs Poor thermal management can lead to early LED product failure. This Technical Note discusses thermal management techniques and good system design.

More information

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company NEETRAC Project Number: 07-113 June 2007 A Research Center of the Georgia Institute of Technology Requested by: Dr. Colin McCullough

More information

ADL110B ADL120 ADL130 ADL140 How to use radar and strike images. Version

ADL110B ADL120 ADL130 ADL140 How to use radar and strike images. Version ADL110B ADL120 ADL130 ADL140 How to use radar and strike images Version 1.00 22.08.2016 How to use radar and strike images 1 / 12 Revision 1.00-22.08.2016 WARNING: Like any information of the ADL in flight

More information

Literature Review. Chapter 2.

Literature Review. Chapter 2. Chapter 2. Literature Review Research programs for gas turbine engines have been active for over half a century. D. G. Wilson (1984) notes that gas-turbine design methods have become classics of the scientific

More information

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE TE 75R RESEARCH RUBBER FRICTION TEST MACHINE Background: The Research Rubber Friction Test Machine offers the ability to investigate fully the frictional behaviour of rubbery materials both in dry and

More information

Experimental Study of Near Wake Flow Behind a Rectangular Cylinder

Experimental Study of Near Wake Flow Behind a Rectangular Cylinder American Journal of Applied Sciences 5 (8): 97-926, 28 ISSN 546-9239 28 Science Publications Experimental Study of Near Wake Flow Behind a Rectangular Cylinder Abdollah Shadaram, Mahdi Azimi Fard and Noorallah

More information

DETECTION OF LAMINAR-TURBULENT TRANSITION IN A FREE-FLIGHT EXPERIMENT USING THERMOGRAPHY AND HOT-FILM ANEMOMETRY

DETECTION OF LAMINAR-TURBULENT TRANSITION IN A FREE-FLIGHT EXPERIMENT USING THERMOGRAPHY AND HOT-FILM ANEMOMETRY DETECTION OF LAMINAR-TURBULENT TRANSITION IN A FREE-FLIGHT EXPERIMENT USING THERMOGRAPHY AND HOT-FILM ANEMOMETRY Peter Schreivogel Akademische Fliegergruppe der TU Dresden e.v. Keywords: boundary-layer

More information

Introduction to Aerospace Engineering

Introduction to Aerospace Engineering 4. Basic Fluid (Aero) Dynamics Introduction to Aerospace Engineering Here, we will try and look at a few basic ideas from the complicated field of fluid dynamics. The general area includes studies of incompressible,

More information

Introduction to Infrared Thermometry

Introduction to Infrared Thermometry TS-104 Introduction to Infrared Thermometry Fig. 1 - Blackbody Radiation Characteristics General Infrared thermometers have the ability to measure temperature without physical contact. The ability to accomplish

More information

Arctice Engineering Module 3a Page 1 of 32

Arctice Engineering Module 3a Page 1 of 32 Welcome back to the second part of the second learning module for Fundamentals of Arctic Engineering online. We re going to review in this module the fundamental principles of heat transfer. Exchange of

More information

Brenda M. Kulfan, John E. Bussoletti, and Craig L. Hilmes Boeing Commercial Airplane Group, Seattle, Washington, 98124

Brenda M. Kulfan, John E. Bussoletti, and Craig L. Hilmes Boeing Commercial Airplane Group, Seattle, Washington, 98124 AIAA--2007-0684 Pressures and Drag Characteristics of Bodies of Revolution at Near Sonic Speeds Including the Effects of Viscosity and Wind Tunnel Walls Brenda M. Kulfan, John E. Bussoletti, and Craig

More information

Transient Temperature Measurements During In-Flight and Wind Tunnel Investigations of Icing Phenomena

Transient Temperature Measurements During In-Flight and Wind Tunnel Investigations of Icing Phenomena In-Flight and Wind Tunnel Investigations of Icing Phenomena DSc, PhD Andrzej J. Panas, Prof. Janusz Terpiłowski and Dr Piotr Waślicki Faculty of Mechatronics, Military University of Technology Warsaw Kaliskiego

More information

Thermal Resistance Measurement

Thermal Resistance Measurement Optotherm, Inc. 2591 Wexford-Bayne Rd Suite 304 Sewickley, PA 15143 USA phone +1 (724) 940-7600 fax +1 (724) 940-7611 www.optotherm.com Optotherm Sentris/Micro Application Note Thermal Resistance Measurement

More information

Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions

Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions James Flaten, U of MN Twin Cities, Minneapolis MN Kaye Smith, St. Catherine University,

More information

Research Article Emissivity Measurement of Semitransparent Textiles

Research Article Emissivity Measurement of Semitransparent Textiles Advances in Optical Technologies Volume 2012, Article ID 373926, 5 pages doi:10.1155/2012/373926 Research Article Emissivity Measurement of Semitransparent Textiles P. Bison, A. Bortolin, G. Cadelano,

More information

GLOWING AND FLAMING AUTOIGNITION OF WOOD

GLOWING AND FLAMING AUTOIGNITION OF WOOD Proceedings of the Combustion Institute, Volume 29, 2002/pp. 289 296 GLOWING AND FLAMING AUTOIGNITION OF WOOD N. BOONMEE and J. G. QUINTIERE Department of Fire Protection Engineering University of Maryland

More information

TAKEOFF CONSIDERATIONS...

TAKEOFF CONSIDERATIONS... CHAPTER 4 TAKEOFFS TAKEOFF CONSIDERATIONS.................. 2-37 AIRSPEED.................................. 2-37 TAKEOFF POWER............................ 2-38 RUNWAY LENGTH REQUIREMENT.............. 2-39

More information

WORLD S CHOICE FOR GEO IMAGING. Advanced Baseline Imager (ABI)

WORLD S CHOICE FOR GEO IMAGING. Advanced Baseline Imager (ABI) WORLD S CHOICE FOR GEO IMAGING Advanced Baseline Imager (ABI) MARKET-LEADING EXPERTISE DELIVERS BEST-IN-CLASS WEATHER IMAGING In cases of extreme weather such as hurricanes, typhoons, blizzards and tornadoes,

More information

Heat Transfer from a Single, Heated Block

Heat Transfer from a Single, Heated Block Heat Transfer from a Single, Heated Block Gerald Recktenwald Portland State University Department of Mechanical Engineering gerry@me.pdx.edu May 16, 2006 These slides are a supplement to the lectures in

More information