Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

Size: px
Start display at page:

Download "Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters"

Transcription

1 International Performance Journal Investigation of Product of Artificially Design Roughened Duct used in Solar Air Heaters January-June 2011, Volume 1, Number 1, pp Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters Tarun Mahajan 1, Ranjit Singh 2 and Brij Bhushan 3 Department of Mechanical Engineering, Beant College of Engineering and Technology, Gurdaspur, Punjab , India, 1 tarun_29@yahoo.co.in. ABSTRACT: Experimental investigation has been reported in the present paper for fully developed turbulent flow in the rectangular duct having absorber plate roughened by fixing plain-woven square wire mesh. Effect of artificial roughness on heat transfer coefficient and friction has been investigated for a range of system and operating parameters. It has been observed that roughened absorber plate results into higher heat transfer coefficient at the cost of frictional penalty. In order to predict performance of the system, Nusselt number and friction factor correlations have been developed by using experimental data. Keywords: Solar air heater, artificial roughness, heat transfer coefficient, Nusselt number and friction factor. Nomenclature A c cross-sectional area of duct, m 2. A o area of orifice plate at the throat, m 2. C d coefficient of discharge. C p specific heat of the air, J kg 1 K 1. D hydraulic diameter of duct, m. e height of roughness element, m. f f s friction factor (dimensionless). friction factor for smooth plate (dimensionless). g acceleration due to gravity, m 2 s 1. 45

2 International Journal of Product Design H height of the duct, m. h t difference of manometric fluid levels in micro-manometer, m. h w difference of water column in U-tube manometer, m. h heat transfer coefficient, W m 2 K 1. k thermal conductivity of air, W m 1 K 1. L length of the test section, m. m mass flow rate of air, kg s 1. Nu Nusselt number (dimensionless). Nu s Nusselt number for smooth plate (dimensionless). p pitch of roughness element, m. Pr Prandlt number (dimensionless). P o pressure drop at the orifice plate, Nm 2. P t pressure drop at the test section, Nm 2. q heat transfer rate, W. Re Reynolds number (dimensionless). T i inlet air temperature of the test section, K. T o outlet air temperature of the test section, K. T am mean temperature of air, K. T pm mean temperature of absorber plate, K. V velocity of air, ms 1. W width of the duct, m. Greek Letters ρ density of air, kg m 3. ρ k density of manometric fluid in micro-manometer, kg m 3. ρ w density of water, kg m 3. β ratio of orifice and pipe diameter (dimensionless). θ inclination of U-tube manometer, degree. µ dynamic viscosity of air, kg/s-m. 46

3 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters 1. INTRODUCTION Energy has been needed and used by human being at an increasing rate for his substance and well being on the planet earth. Continuous use of fossil fuels have resulted energy crisis and environmental threats. Now the need has been felt to have inexhaustible and clean energy resources. Solar energy is considered to be primary energy source for all forms of energy. It is free and available almost everywhere. Simplest method to utilize solar radiation is to convert it into thermal energy for heating applications by using solar collectors. Solar air heaters because of their intrinsic simplicity and minimum use of materials are cheap and are used for many applications like space heating, timber seasoning, crop drying etc. Thermal efficiency of solar air heaters in comparison of solar water heaters is generally considered poor because of their inherently low heat transfer capability between the absorber plate and air flowing in the duct. Methodology of creating artificial roughness on the surface of absorber plate is considered to be an effective technique for enhancing heat transfer coefficient in order to increase heat transfer rate between absorber plate and air flowing through the duct. However, it results into an increase in friction loss. Therefore, turbulence must be created only in the region very close to the absorber surface i.e. in laminar sub-layer only. It can be produced by several methods such as by wire fixation in the form of transverse continuous ribs, transverse broken ribs, inclined and V-shaped or staggered ribs; rib formation by machining process in the form of chamfered ribs, wedge shaped ribs, combination of different integral rib roughness elements and by using expanded metal mesh ribs as has been described by Bhushan and Singh [1]. Prasad and Mullick [2] utilized artificial roughness in the duct used in solar heater in the form of small diameter wires to increase heat transfer coefficient. Prasad and Saini [3] investigated fully developed turbulent flow in the duct with a small diameter protrusion wire on the absorber plate. Muluwork et al. [4] compared thermal performance of staggered discrete V-apex up and down with corresponding transverse staggered discrete ribs. Karwa et al. [5] performed experimental study to predict effect of rib head chamfer angle and duct aspect 47

4 International Journal of Product Design ratio on heat transfer and friction loss in a rectangular duct roughened with integral chamfered ribs. Bhagoria et al. [6] performed experimental investigation to determine the effect of relative roughness pitch, relative roughness height and wedge angle on heat transfer and friction loss in a solar air heater roughened duct having wedge shaped rib roughness. Momin et al. [7] experimentally investigated effect of geometrical parameters of V-shaped ribs on heat transfer and fluid flow characteristics in rectangular duct used in solar air heaters. Jaurker et al. [8] experimentally investigated heat transfer and friction characteristics of rib-grooved artificial roughness. Varun et al. [9] presented a review on artificial roughness investigations reported in literature. It has been observed from various experimental investigations on artificial roughness that creating artificial roughness on absorber plate is a tedious task and may not be economically feasible. A suitable geometry of roughness element therefore needs to be selected, which besides being easily available should be easy to fix on the absorber plate. In the same direction, Saini and Saini [10] used expanded metal mesh to create artificial roughness on absorber plate and investigated effect of system and operating parameters on heat transfer and friction loss. Similar to expanded metal mesh, plain-woven square wire mesh available in common market can be used for generating artificial roughness on the absorber plate. It has been observed that heat transfer and pressure drop data for such type of a wire mesh is not reported in the literature. Therefore, it was decided to carry out experimental investigation to study performance of artificially roughened duct with plain-woven square wire mesh of two types. In the present paper an experimental investigation has been reported, in which heat transfer and pressure drop data have been generated for artificially roughened duct and used to develop Nusselt number and friction factor correlations for predicting performance of the system. 2. EXPERIMENTAL SET-UP AND PROCEDURE In order to carry out present experimental investigation, a test rig was designed and fabricated as per guidelines proposed in literature 48

5 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters for similar experimental investigations. Schematic and photogaraphic view of experimental set-up are shown in ig. (1) and ig. (2) respectively. It consists of an air duct along with temperature and pressure drop measuring instruments, electric heater assembly, pipe line, flow measuring device, centrifugal blower and gate valves. Air duct comprised 20 mm thick wooden ply board and size of the duct was mm. Length of entry, test and exit sections were kept 900 mm, 1000 mm and 500 mm respectively. Length of converging plenum on exit side of the duct was 600 mm. An electric heater having size of mm was fabricated by combining series and parallel loops of heating wire on mica sheet to get uniform heat flux. Backside of the heater was insulated with glass wool to minimize the heat loss. Heater was placed on top of the duct and variac was provided to control electric supply to it. igure 1: Schematic of Experimental Set-Up. 49

6 International Journal of Product Design igure 2: Photographic View of Experimental Set-Up. Absorber plate being a 20 SWG GI sheet of mm size was painted black on heater side and artificial roughness was provided on air duct side by fixing wire mesh. Mass flow rate of the air was measured by means of an orifice-meter connected with a U- tube manometer. low of air through duct was smoothly controlled by means of two gate valves provided at entry and exit of centrifugal blower. Thermocouples made from copper-constantan wire were used to measure temperature of air and absorber plate at different locations as shown in igs. (3) and (4). igure 3: Different Locations of Thermocouples used to Measure Absorber Plate Temperature. 50

7 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters igure 4: Different Locations of Thermocouples used to Measure Air Temperature in the Duct. igure 5: Photographic View of P-1 and P-2 Type of Plain-Woven Square Wire Mesh used in Experimental Investigation. Micro-manometer was used to measure pressure drop across test section of the duct. Photographic views of two types of wire mesh used in the present experimental investigation are shown in ig. (5). Specifications of wire meshes are given in Table 1. Table 2 shows range/value of parameters used in present experimental investigation. Wire mesh was glued on to the underside of the absorber plate and ends of the wire mesh were fixed with screws to ensure good contact between the absorber plate and wire mesh. Measuring instruments like orifice meter, temperature indicator, temperature selector switch, micro manometer and U-tube manometer were properly checked and calibrated before starting the experimentation. All joints in the test rig were thoroughly checked to avoid any leakage. ive values of flow rate were used for each set and following data were collected at an interval of one hour in each set of experimentation: (i) Pressure drop across orifice meter to measure flow rate of air. (ii) Pressure drop across test section of duct. 51

8 International Journal of Product Design (iii) Temperature of absorber plate at various locations in test section of the duct. (iv) Temperature of air at various locations in test section of the duct. (v) Voltage and current supplied to electric heater. Table 1 Specifications of Wire Mesh used as Roughness Element. Plate No. Geometry Specifications e(mm) p(mm) P-1 Plain-woven square wire mesh P-2 Plain-woven square wire mesh Table 2 Range/Value of Parameters. S. No. Parameter Range/Value 1. Reynolds number Mass flow rate of air kg/s 3. Duct aspect ratio (W/H) Relative roughness height (e/d) 0.022, Relative roughness pitch (p/e) 1.75, 5.65 Accuracy of experimental data was verified by conducting experiments for a conventional smooth duct. Nusselt number and friction factor values were determined from experimental data and compared with the values obtained from the following Nusselt number and friction factor correlations reported by Momin et al. [7] for rectangular smooth duct. where Modified Dittus-Boelter correlation for Nusselt number is Nu s = Re 0.8 Pr 0.4 2R av D e ( H / W 1) = H / W 52 2R av Modified Blasius equation for friction factor is D e (1) f s = Re (2)

9 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters igure 6: Comparison of Experimental and Predicted Data of Nusselt Number for Smooth Absorber Plate. igure 7: Comparison of Experimental and Predicted Data of riction actor for Smooth Absorber Plate. 53

10 International Journal of Product Design ig. (6) and ig. (7) shows comparison of experimental and predicted data of Nusselt number and friction factor for smooth absorber plate. A reasonably good agreement between experimental and predicted data ensures accuracy of the data being collected from self designed and fabricated experimental set-up. Error analysis based on the procedure described by Holman [11] has been carried out to find out uncertainties in measured/calculated values of experimental data. Uncertainty in Reynolds number, Nusselt number and friction factor values has been estimated as 1.65%, 1.73%, and 3.28% respectively. 3. DATA REDUCTION ollowing equations were used for calculating pressure drop across test section and orifice plate ( P t and P o ), mass flow rate of air (m ), velocity of air (V), heat transfer rate (q), heat transfer coefficient (h), Nusselt number (Nu) and friction factor (f): Also P t = ρ k g( h t )...(3) P o = ρ w g ( h w )...(4) m = C d A o V = m ρ A Therefore, from Eqs. (7) and (8) c 2ρ po Sinθ 4 1 β (5)...(6) q = m C p (T o T i )...(7) q = ha c (T pm T am )...(8) h = q A ( T ) T c pm am...(9) Where T pm and T am are mean temperature of absorber plate and air. These were determined from temperature values recorded for absorber plate and air at different locations along test section of the

11 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters duct. Reynolds number, Nusselt number and friction factor values were calculated by using the following relationships: Re = VD ρ µ...(10) Nu = hd k 2 PD t f = 2 4ρLV...(11)...(12) 4. RESULTS AND DISCUSSION Presence of wire mesh in the flow regimes cause vortices, help in increasing turbulence and hence enhancing heat transfer as well as friction loss. Effect of various flow and roughness parameters on heat transfer and friction characteristics has been investigated and results have been reported and discussed in the present section. ig. (8) represents variation of heat transfer coefficient as a function of mass flow rate of air. It can be observed that for a given type of wire mesh, heat transfer coefficient increases monotonously with increase of mass flow rate of air for smooth as well as roughened plate. Experimental data show that heat transfer coefficient for roughened plate is considerably higher as compared to smooth plate. It may happen due to turbulence caused by breakage of laminar sub-layer with application of artificial roughness. It has also been observed from these results that P-1 type of plain-woven square wire mesh has higher heat transfer coefficient than that of P-2 type of plain-woven square wire mesh. ig. (9) shows variation of Nusselt number as a function of Reynolds number for smooth and roughened absorber plates. Test results show that enhancement in Nusselt number for roughened plates is less at lower values of Reynolds number. However, enhancement in Nusselt number increases at higher rate for higher values of Reynolds number for both types of roughened absorber plates. It may be due to higher local distur-bances and secondary flow formation by roughness elements in flow regimes as reported by Saini and Saini [10]. 55

12 International Journal of Product Design ig. (10) shows variation of pressure drop as a function of mass flow rate for smooth and roughened absorber plates. Due to local disturbances and generation of secondary flows by roughened elements, increase in pressure drop has been observed as compared to smooth plate. ig. (11) shows variation of friction factor as a function of Reynolds number for smooth and roughened absorber plates. riction factor decreases with increase of Reynolds number as has been expected. With increase of Reynolds number boundary layer thickness decreases and roughness element begins to project beyond laminar sub-layer. This reduction in the boundary layer thickness increases heat transfer coefficient as well as friction loss as reported by Karwa et al. [5]. The shedding of vortices also causes additional loss of energy resulting in increased friction loss. It has also been observed in the present experimental investigation that heat transfer coefficient and friction loss decrease with increase in relative roughness pitch (p/e) as reported by Verma and Prasad [13]. igure 8: Variation of Heat Transfer Coefficient with Mass low Rate for Smooth and Roughened Absorber Plates. 56

13 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters igure 9: Variation of Nusselt Number with Reynolds Number for Smooth and Roughened Absorber Plates. igure 10: Variation of Pressure Drop with Mass low Rate for Smooth and Roughened Absorber Plates. 57

14 International Journal of Product Design igure 11: Variation of riction actor with Reynolds Number for Smooth and Roughened Absorber Plates. 5. DEVELOPMENT O NUSSELT NUMBER AND RICTION ACTOR CORRELATIONS It has been observed that Nusselt number and friction factor are strong functions of Reynolds number. unctional relationships for Nusselt number and friction factor can therefore be written as: Nu = λ(re)...(13) f = λ(re)...(14) As per procedure described by Singh et al. [12] and using Sigma plot software following Nusselt number and friction factor correlations were developed corresponding to experimental data as shown in igs. (8) and (10) in order to predict performance of the system: for P-1 type of plain-woven square wire mesh Nu = Re (15) f = 68 Re (16) and for P-2 type of plain-woven square wire mesh Nu = Re (17) f = Re (18) 58

15 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters igure 12: Comparison of Predicted and Experimental Data of Nusselt Number for P-1 Type of Plain-Woven Square Wire Mesh. igure 13: Comparison of Predicted and Experimental Data of Nusselt Number for P-2 Type of Plain-Woven Square Wire Mesh. 59

16 International Journal of Product Design igure 14: Comparison of Predicted and Experimental Data of riction actor for P-1 Type of Plain-Woven Square Wire Mesh. igure 15: Comparison of Predicted and Experimental Data of riction actor for P-2 Type of Plain-Woven Square Wire Mesh. 60

17 Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters igs. (12), (13), (14) and (15) show comparison of experimental data and that predicted from above developed Nusselt number and friction factor correlations for both types of roughened absorber plates. Average absolute percentage deviations between experimental and predicted values of Nusselt number and friction factor for P-1 type of plain-woven square wire mesh have been found to be ± 2.5 % and ± 16 % respectively, whereas the corresponding values for P-2 type of plain-woven square wire mesh have been found to be ± 3.5 % and ± 14 % respectively. 6. CONCLUSIONS An experimental investigation on performance of artificially roughened duct used in solar air heaters has been reported in the present paper. Effect of artificial roughness (created by fixing plainwoven square wire mesh on absorber plate) on heat transfer and friction has been investigated for Reynolds numbers range of It has been observed that roughened absorber plate results into higher heat transfer coefficient at the cost of frictional penalty. In order to predict performance of the system Nusselt number and friction factor correlations have been developed by using experimental data. REERENCES [1] B. Bhushan, R. Singh, A Review on Methodology of Artificial Roughness Used in Duct of Solar Air Heaters, Energy, 35 (2010) pp [2] K. Prasad, S.C. Mullick, Heat Transfer Characteristics of a Solar Air Heater Used for Drying Purposes, Appl. Energy, 13 (1983), pp [3] B.N. Prasad, J.S. Saini, Effect of Artificial Roughness on Heat Transfer and riction actor in Solar Air Heater, Solar Energy, 41 (1988), pp [4] K.B. Muluwork, J.S. Saini, S.C. Solanki, Studies on Discrete Rib Roughened Solar Air Heaters, In: Proceedings of National Solar Energy Convention-98, Roorkee, India, pp , [5] R. Karwa, S.C. Solanki, J.S. Saini, Heat Transfer Coefficient and riction actor Correlations for the Transitional low Regime in Rib Roughened Rectangular Ducts, International Journal of Heat and Mass Transfer, 42 (1999), pp [6] J.L. Bhagoria, J.S. Saini, S.C. Solanki, Heat Transfer Coefficient and riction actor Correlations for Rectangular Solar air Heater Duct Having Transverse 61

18 International Journal of Product Design Wedge Shaped Rib Roughness on the Absorber Plate, Renewable Energy, 25 (2002), pp [7] A.M.E. Momin, J.S. Saini, S.C. Solanki, Heat Transfer and riction in Solar Air Heater Duct with V-shaped Rib Roughness on Absorber Plate, International Journal of Heat and Mass Transfer, 45 (2002), pp [8] A.R. Jaurker, J.S. Saini, B.K. Gandhi, Heat Transfer and riction Characteristics of Rectangular Solar Air Heater Duct using Rib-Grooved Artificial Roughness, Solar Energy, 80 (2006), pp [9] Varun, R.P. Saini, S.K. Singal, A Review on Roughness Geometry used in Solar Air Heaters, Int. J. Solar Energy, 81 (2007), pp [10] R.P. Saini, J.S. Saini, Heat Transfer and riction actor Correlations for Artificially Roughened Ducts with Expanded Metal Mesh as Roughened Element, International Journal of Heat and Mass Transfer, 40 (1997), pp [11] J.P. Holman, Experimental Methods for Engineers, Tata McGraw-Hill, New Delhi, [12] R. Singh, R.P. Saini, J.S. Saini, Nusselt Number and riction actor Correlations for Packed Bed Solar Energy Storage System Having Large Sized Elements of Different Shapes, Solar Energy, 80 (2006), pp [13] S.K. Verma, B.N. Prasad, Investigation for the optimal Thermo-Hydraulic Performance of Artificially Roughened Solar Air Heaters, Renewable Energy, 20 (2000), pp

International Journal of Advanced Engineering Technology E-ISSN

International Journal of Advanced Engineering Technology E-ISSN Research Article EFFECT OF ROUGHNESS ELEMENT PITCH ON HEAT TRANSFER AND FRICTION CHARACTERISTICS OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATER DUCT Aman Soi*, Ranjit Singh, Brij Bhushan Address for Correspondence

More information

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online): 2321-0613 Experimental Investigation for Enhancement of Heat Transfer in Two Pass Solar Air Heater

More information

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB Piyush Kumar Jain and Atul Lanjewar Department of Mechanical Engineering, Maulana Azad

More information

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness Advances in Materials Science and Mechanical Engineering Research Volume 1, Number 1 (2015), pp. 25-32 International Research Publication House http://www.irphouse.com Exergy Analysis of Solar Air Collector

More information

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater Alok Kumar Rohit 1, A.M. Lanjewar 2 1PhD Scholar, Mechanical Engineering Department, AISECT University Bhopal, M.P. - 462024 India

More information

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER C.B.Pawar*, K.R.Aharwal 1 and Alok Chaube 2 1. Department of Mechanical Engineering, Shri

More information

UNCORRECTED PROOF ARTICLE IN PRESS

UNCORRECTED PROOF ARTICLE IN PRESS 1 Available online at www.sciencedirect.com Solar Energy xxx (28) xxx xxx www.elsevier.com/locate/solener 2 Development of correlations for Nusselt number and friction factor 3 for solar air heater with

More information

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 7, Issue 10 (July 2013), PP. 55-63 Thermo-Hydraulic Performance of a Roughened Square

More information

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN Numerical Analysis Of Heat Transfer And Fluid Flow Characteristics In Different V-Shaped Roughness Elements On The Absorber Plate Of Solar Air Heater Duct Jitesh Rana, Anshuman Silori, Rohan Ramola Abstract:

More information

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct Research Article International Journal of Thermal Technologies ISSN 2277-4114 2013 INPRESSCO. All Rights Reserved. Available at http://inpressco.com/category/ijtt Computational Fluid Dynamics Based Analysis

More information

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review Gulshan Singh Baghel 1, Dr. A R Jaurker 2 1. Student, M.E. (Heat Power engineering), Jabalpur

More information

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER THERMAL SCIENCE: Year 2018, Vol. 22, No. 2, pp. 963-972 963 COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER by Jitesh RANA, Anshuman SILORI, Rajesh MAITHANI *, and

More information

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap Research Article International Journal of Current Engineering and Technology ISSN 2277-4106 2013 INPRESSCO. All Rights Reserved. Available at http://inpressco.com/category/ijcet Augmented Heat Transfer

More information

CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct

CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct Suman Saurav #1, V.N.Bartaria *2 # M.E Scholar,Lakshmi Narain College of Technology, Bhopal,Madhya Pradesh- 462041(India) * Mechanical

More information

ARTICLE IN PRESS. K.R. Aharwal a,, B.K. Gandhi b, J.S. Saini b

ARTICLE IN PRESS. K.R. Aharwal a,, B.K. Gandhi b, J.S. Saini b newable Energy 33 (2008) 585 596 www.elsevier.com/locate/renene Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar

More information

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May-2015 28 CFD BASED HEAT TRANSFER ANALYSIS OF SOLAR AIR HEATER DUCT PROVIDED WITH ARTIFICIAL ROUGHNESS Vivek Rao, Dr. Ajay

More information

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness Bonfring International Journal of Industrial Engineering and Management Science, Vol. 4, No. 3, August 2014 115 A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined

More information

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs Faisal mujib¹, Ravindra mohan² ¹Research Scholar, ²Assistant Professor, Mechanical Engineering Dept. IES

More information

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

Experimental investigation of heat transfer enhancement by u-shaped Turbulator "Experimental investigation of heat transfer enhancement by u-shaped Turbulator" Pawar Shubham (1),Pailwan Vidyadhar (2), Kothawale Shridhar (3), Vaibhav Sonavane (4),Akshay Londhe (5) 1,2,3,4UG Scholar,

More information

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT Rahul Pratap Singh 1, Sudhanshu Mishra 2 1M.Tech, Research Scholar, Department of Mechanical Engineering, Shri Shankaracharya

More information

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate International Journal of Engineering Science Invention ISSN (Online): 2319 6734, ISSN (Print): 2319 6726 Volume 3 Issue 8 ǁ August 2014 ǁ PP.01-10 Performance evaluations of two pass solar air heater using

More information

CFD analysis of solar air heater having absorber plate roughened with compound turbulators

CFD analysis of solar air heater having absorber plate roughened with compound turbulators CFD analysis of solar air heater having absorber plate roughened with compound turbulators 1 Mr. Obaid Ul Haque Ansari, 2 Dr. V.R. Kalamkar, 1 PG Student, 2 Associate Professor 1 Department of Mechanical

More information

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001 Renewable Energy 25 (2002) 341 369 www.elsevier.nl/locate/renene Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness

More information

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater 1 Vikas Kesharwani, 2 Ravi Vishwakarma 1 Department of Mechanical Engineering,

More information

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates International Journal of Thermal Technologies E-ISSN 2277 4114 2018 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Theoretical prediction of performance

More information

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate Jitender Singh Khurana #1, Dr.Chandresh Sharma *2, Ramesh Parihar #3 #1 Sr. Lecturer, mechanical,

More information

Correlations for Double Flow Double Pass SAH with Smooth Absorber Plate

Correlations for Double Flow Double Pass SAH with Smooth Absorber Plate nternational Journal of Current Engineering and Technology E-SSN 2277 4106, P-SSN 2347 5161 2016 NPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Correlations

More information

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate Advanced Computational Methods in Heat Transfer IX 43 Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate A. Chaube 1, P. K. Sahoo

More information

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct 4th International Conference on Mechanical, Electronics and Mechatronics Engineering (ICMEME'2) Dec. -16, 2 Pattaya (Thailand) Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of

More information

Exergetic Performance Evaluation and Comparative Study of A Roughened Solar Air Heater using MATLAB

Exergetic Performance Evaluation and Comparative Study of A Roughened Solar Air Heater using MATLAB Exergetic Performance Evaluation and Comparative Study of A Roughened Solar Air Heater using MATLAB Ankit Kumar 1, 1 CSIR-Indian Institute of Petroleum, Dehradun, Uttarakhand, 48005, India Vijay Singh

More information

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate Rahul kumar¹, Ravindra mohan² ¹Research Scholar, ²Assistant Professor, Mechanical Engineering

More information

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate International Journal Of Engineering Research And Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 13, Issue 9 (September 2017), PP.12-19 CFD Analysis for Thermal Behavior of Turbulent

More information

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.5, No.2, pp 964-971, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in

More information

Heat transfer and fluid flow analysis of roughness ribin solar air heater duct by computational fluid dynamics (CFD)

Heat transfer and fluid flow analysis of roughness ribin solar air heater duct by computational fluid dynamics (CFD) Current World Environment Vol. 5(2), 279-285 (2010) Heat transfer and fluid flow analysis of roughness ribin solar air heater duct by computational fluid dynamics (CFD) PRASHANT BAREDAR¹, SHANKAR KUMAR²,

More information

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs #1 Sandip T.Jadhav, #2 R. D. Shelke, #3 H. N. Deshpande #1 Research scholar, Department of Mechanical Engineering, PES s MCOE,SavitribaiPhule

More information

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

International Journal of Engineering, Business and Enterprise Applications (IJEBEA) International Association of Scientific Innovation and Research (IASIR) (An Association Unifying the Sciences, Engineering, and Applied Research) International Journal of Engineering, Business and Enterprise

More information

Nusselt Number Correlation of SAH

Nusselt Number Correlation of SAH Open Access Journal Journal of Power Technologies 93 (2) (2013) 100 110 journal homepage:papers.itc.pw.edu.pl Nusselt Number Correlation of SAH Foued Chabane,a,b, Noureddine Moummi a,b, Said Benramache

More information

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib 1 Miss. Ashwini Vasant Thakare, 2 Dr. J. A. Hole 1 M.Tech Student of JSPM Narhe Technical

More information

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT International Journal of Mechanical Engineering and Technology (IJMET) Volume 10, Issue 03, March 2019, pp. 555-566. Article ID: IJMET_10_03_057 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=10&itype=3

More information

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 13, Issue 6 Ver. II (Nov. - Dec. 2016), PP 26-31 www.iosrjournals.org Experimental Heat transfer

More information

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB University of Technology Department Mechanical engineering Baghdad, Iraq ABSTRACT - This paper presents numerical investigation of heat

More information

ENHANCEMENT OF THE HEAT TRANSFER RATE IN FREE CONVECTION SOLAR AIR HEATER USING PIN SHAPED ARTIFICIAL ROUGHNESS ON ABSORBER PLATE

ENHANCEMENT OF THE HEAT TRANSFER RATE IN FREE CONVECTION SOLAR AIR HEATER USING PIN SHAPED ARTIFICIAL ROUGHNESS ON ABSORBER PLATE ENHANCEMENT OF THE HEAT TRANSFER RATE IN FREE CONVECTION SOLAR AIR HEATER USING PIN SHAPED ARTIFICIAL ROUGHNESS ON ABSORBER PLATE Syed E. Gilani 1, Hussain H. Al-Kayiem 1, Buschmann Matthias 2 and Dereje.

More information

Second law optimization of a solar air heater having chamfered rib groove roughness on absorber plate

Second law optimization of a solar air heater having chamfered rib groove roughness on absorber plate Renewable Energy 3 (007) 1967 1980 www.elsevier.com/locate/renene Second law optimization of a solar air heater having chamfered rib groove roughness on absorber plate Apurba Layek a,, J.S. Saini b, S.C.

More information

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap International Journal of Thermal Technologies E-ISSN 2277 4114 2017 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of rib height on heat transfer

More information

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface 1 Adimurthy. M 1 BLDEA s VP DR. P G Halakatti college

More information

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF WIRE SCREEN MATRIX PACKED SOLAR AIR HEATER

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF WIRE SCREEN MATRIX PACKED SOLAR AIR HEATER EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF WIRE SCREEN MATRIX PACKED SOLAR AIR HEATER P. Verma 1, L. Varshney 1 * 1 Department of Mechanical Engineering, College of Technology, G.B. Pant University

More information

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2015INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Investigation

More information

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT 62 CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT 5.1 INTRODUCTION The primary objective of this work is to investigate the convective heat transfer characteristics of silver/water nanofluid. In order

More information

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 62-67 www.iosrjournals.org Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management A REVIEW REPORT FOR HEAT TRANSFER AND FLUID FLOW CHARECTRISTICS Dr. Ashwini Kumar* * Professor (Asst.), Department of Mechanical Engineering, Parikrama College of Engineering, Ahmednagar-414701, Maharashtra,

More information

Performance Of Solar Air Heaters With Corrugated Absorber Plate- A CFD Approach

Performance Of Solar Air Heaters With Corrugated Absorber Plate- A CFD Approach Performance Of Solar Air Heaters With Corrugated Absorber Plate- A CFD Approach Dr. Ashwini Kumar Prof. Avinash Gholap Prof. Rohit Gangarde Professor (Asst.), Department of Mechanical Engineering, H.S.B.P.V.T

More information

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate ISSN: 2454-132X Impact factor: 4.295 (Volume 4, Issue 3) Available online at: www.ijariit.com CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber

More information

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins 1 Mohit Taneja, 2 Sandeep Nandal, 3 Arpan Manchanda, 4 Ajay

More information

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS THERMAL SCIENCE, Year 015, Vol. 19, No. 6, pp. 19-31 19 EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS by Sivakumar KARTHIKEYAN a*, Natarajan

More information

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA ISBN 978-93-84422-63-9 Proceeding of 2016 International Conference on Advances in Software, Control and Mechanical Engineering (ICSCME'16) Kyoto (Japan) April 12-13, 2016 pp.22-28 New Correlations and

More information

Thermal Efficiency and Exergy Analysis of a Solar Collector by using Roughened Absorber Plate

Thermal Efficiency and Exergy Analysis of a Solar Collector by using Roughened Absorber Plate Thermal Efficiency and Exergy Analysis of a Solar Collector by using Roughened Absorber Plate Shashikant Nagpure (Research Scholar) Mechanical Engg. Department MANIT,Bhopal, MP, India Dr. K. R.Aharwal

More information

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015 Heat Transfer Enhancement in a Tube using Elliptical-Cut Twisted Tape Inserts Pratik P. Ganorkar 1, R.M. Warkhedkar 2 1 Heat power Engineering, Department of Mechanical Engineering, Govt. collage of engineering

More information

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs Analysis & erimental Investigation to improve Heat Transfer Enhancement in flat with W Ribs Jayshri S Gulave 1, Kulkarni V.S. 2 Parag S. Desale 3 1 M.E Student Matoshri college of Engineering, Nashik,

More information

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate Avinash A. Ranaware Mechanical Engineering Department ME Student, G. S. Moze COE, Balewadi Pune, India aviranaware83@yahoo.in

More information

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY CFD SIMULATION AND EXPERIMENTAL VERIFICATION OF AIR FLOW THROUGH HEATED PIPE Jamuna A B*, Somashekar V *Asst. Professor, Department

More information

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Comparative

More information

TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL

TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL THERMAL SCIENCE: Year 2014, Vol. 18, No. 2, pp. 419-430 419 TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL by Md. Julker NINE a, Gyeong Hwan LEE a, HanShik CHUNG

More information

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface www.ierjournal.org International Engineering search Journal (IERJ) Volume 1 Issue 6 Page 42-47, 21, ISSN 239-1621 ISSN 239-1621 Experimental Investigation of Forced Convection Heat Transfer Augmentation

More information

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator Thermo-Hydraulic performance of Internal finned tube Automobile Radiator Dr.Kailash Mohapatra 1, Deepiarani Swain 2 1 Department of Mechanical Engineering, Raajdhani Engineering College, Bhubaneswar, 751017,

More information

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts ISSN 2395-1621 Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts #1 Imran Quazi, Prof. #2 V.R.Mohite, #3 Prof. J Bali 1 imranquazi1987@gmail.com 2 vrmohite@gmail.com

More information

Analysis, Design and Fabrication of Forced Convection Apparatus

Analysis, Design and Fabrication of Forced Convection Apparatus Analysis, Design and Fabrication of Forced Convection Apparatus Shajan K. Thomas 1, Vishnukumar C M 2, Vishnu C J 3, Alex Baby 4 Assistant Professor, Dept. of Mechanical Engineering, Toc H Institute of

More information

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 10, Issue 3 (Nov. - Dec. 2013), PP 30-35 Cfd Simulation and Experimentalverification of Air Flow

More information

Heat transfer characteristics in forced convection through a rectangular channel with 60 tilted staggered ribs

Heat transfer characteristics in forced convection through a rectangular channel with 60 tilted staggered ribs Journal of Physics: Conference Series OPEN ACCESS Heat transfer characteristics in forced convection through a rectangular channel with 60 tilted staggered ribs To cite this article: M Cucchi et al 2014

More information

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid 1 Krishna S. Borate, 2 A.V. Gawandare, 3 P.M. Khanwalkar 1,2,3 Department of Mechanical Engineering, Sinhgad College

More information

Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts

Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts K.G.KULKARNI Appearing in ME ( HEAT POWER), PES s Modern College Of Engineering

More information

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER 1.1 AIM: To determine the co-efficient of discharge of the orifice meter 1.2 EQUIPMENTS REQUIRED: Orifice meter test rig, Stopwatch 1.3 PREPARATION 1.3.1

More information

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles Journal of Mathematics and Statistics Original Research Paper Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles 1 Amnart Boonloi and 2 Withada

More information

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker Subodh Kumar * Centre for Energy Studies, Indian Institute of Technology, Hauz Khas, New Delhi 110016, India Received

More information

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER 1 Navanath.G.Ghodake, 2 Prof.MRC. Rao, 3 Dr. R. R. Arakerimath 1 ME heat power student, 2 professor, 3 Professor & Dean

More information

AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE

AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE Dr. Ahmed F. Khudheyer Ali Jawad Obaid Mazin Y. Abdul-Kareem ahyaja@yahoo.com

More information

Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface

Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface Journal of Mathematics and Statistics Original Research Paper Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface 1 Amnart Boonloi and 2 Withada

More information

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE Thamer Khalif Salem Mechanical Engineering, College of Engineering, Tikrit University, IRAQ. thamer_khalif@yahoo.com

More information

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing ISSN 2395-1621 Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing #1 Atole Santosh, #2 Channapattana S.V 1 santoshatole10@gmail.com 1 svchanna@yahoo.co.in

More information

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube by using Combined Wire Coil and Wavy Strip with Central Clearance Dipan Deb, Sajag Poudel Abstract: The experimental friction

More information

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS K. Sivakumar 1, E. Natarajan and N. Kulasekharan 3 1 Valliammai Engineering College, Chennai, India Institute of Energy Studies,

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 ISSN 0976 6340 (Print) ISSN 0976 6359 (Online) Volume

More information

AUGMENTATION OF HEAT TRANSFER USING COILED POROUS TWISTED TAPE INSERT

AUGMENTATION OF HEAT TRANSFER USING COILED POROUS TWISTED TAPE INSERT Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 2015 (ICMERE2015) 26 29 November, 2015, Chittagong, Bangladesh ICMERE2015-PI-112 AUGMENTATION OF HEAT TRANSFER

More information

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition Sādhanā Vol. 40, Part 2, April 2015, pp. 467 485. c Indian Academy of Sciences Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition RAMBIR BHADOURIYA,

More information

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts Proceedings of the 2 nd International Conference on Fluid Flow, Heat and Mass Transfer Ottawa, Ontario, Canada, April 30 May 1, 2015 Paper No. 143 Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

More information

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER THERMAL SCIENCE: Year 2014, Vol. 18, No. 4, pp. 1355-1360 1355 EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER by Rangasamy RAJAVEL Department of Mechanical Engineering, AMET University,

More information

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle Journal of Mathematics and Statistics Original Research Paper Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle 1 Amnart Boonloi and 2 Withada

More information

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study DOI: http://dx.doi.org/10.30684/etj.36.11a.4 Akram H. Abed Electro-Mechanical Eng. Dept., Baghdad, Iraq. moon.nassr@gmail.com Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat

More information

Experimental Study of Fluid Flow and Heat Transfer Characteristics of Rough Surface, Impinged by a Confined Laminar Slot Air Jet

Experimental Study of Fluid Flow and Heat Transfer Characteristics of Rough Surface, Impinged by a Confined Laminar Slot Air Jet Experimental Study of Fluid Flow and Heat Transfer Characteristics of Rough Surface, Impinged by a Confined Laminar Slot Air Jet M. Adimurthy 1,, 1 Associate professor, Department of Automobile Engineering,

More information

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles M.A. AMRAOUI a, K. ALIANE b a. Department of Mechanical Engineering, Faculty of Technology, University of Tlemcen,

More information

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators search Article International Journal of Thermal Technologies E-ISSN 2277 4114 214 INPRESSCO, All Rights served Available at http://inpressco.com/category/ijtt/ merical Heat Transfer Study of Turbulent

More information

Forced Convection Heat Transfer Augmentation from Ribbed Surface

Forced Convection Heat Transfer Augmentation from Ribbed Surface www.ierjournal.org International Engineering search Journal (IERJ) Volume 1 Issue 6 Page 44-41, 21, ISSN 239-1621 ISSN 239-1621 Forced Convection Heat Transfer Augmentation from Ribbed Surface #1 Varsha

More information

International Journal of Advanced Engineering Research and Studies E-ISSN

International Journal of Advanced Engineering Research and Studies E-ISSN Research Paper ANALYSIS OF TWISTED TAPE WITH STRAIGHT WINGLETS TO IMPROVE THE THERMO-HYDRAULIC PERFORMANCE OF TUBE IN TUBE HEAT EXCHANGER Mr.S.D.Patil 1, Prof. A.M. Patil 2, Prof. Gutam S. Kamble 3 Address

More information

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER HESHAM G. IBRAHIM Assist. Prof., Department of Mechanical Engineering, Faculty of Marine Resources, Al-Asmarya Islamic

More information

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER HESHAM G. IBRAHIM Assist. Prof., Department of Mechanical Engineering, Faculty of Marine Resources, Al-Asmarya Islamic

More information

Flow and Temperature Analysis inside Flat Plate Air Heating Solar Collectors

Flow and Temperature Analysis inside Flat Plate Air Heating Solar Collectors International Journal of Recent Development in Engineering and Technology Website: www.ijrdet.com (ISSN 2347-6435(Online) Volume 3, Issue 3, September 24) Flow and Temperature Analysis inside Flat Plate

More information

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced. 1 Heat Transfer F12-ENG-135 - Lab #4 Forced convection School of Engineering, UC Merced. October 23, 2012 1 General purpose of the Laboratory To gain a physical understanding of the behavior of the average

More information

Experimental Investigation of Heat Transfer Analysis of Ribbed Duct for Thermal Performance Enhancement

Experimental Investigation of Heat Transfer Analysis of Ribbed Duct for Thermal Performance Enhancement Experimental Investigation of Heat Transfer Analysis of Ribbed Duct for Thermal Performance Enhancement K. R. Chavan, N.D. Dhawale, D.N.Adling, K.P.Deshmukh, S. K. Kalukhe, S.A.More Abstract -In this paper

More information

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2017 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Enhancement

More information

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: , ICAER 2011 AN EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF HEAT LOSSES FROM THE CAVITY RECEIVER USED IN LINEAR FRESNEL REFLECTOR SOLAR THERMAL SYSTEM Sudhansu S. Sahoo* a, Shinu M. Varghese b, Ashwin

More information

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES THERMAL SCIENCE: Year 2013, Vol. 17, No. 4, pp. 1125-1137 1125 COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

More information