Ferenc SZABÓ, Péter CSUTI

Size: px
Start display at page:

Download "Ferenc SZABÓ, Péter CSUTI"

Transcription

1 Ferenc SZABÓ, Péter CSUTI University of Pannonia, Department of Electrical Engineering and Information Systems, Veszprém, Hungary Lux et Color Vesprimiensis 2012 October 29 30

2 Full-scale experimental rooms at University of Pannonia 2 rooms with identical dimensions: simulate kitchen, dining environment simulate living room environment Each room is equipped with 4 reference and 4 LED luminaires Air conditioned

3 Full-scale experimental rooms at University of Pannonia Living room environment Reference lamps: Halogen 3000K CCT LED SPD: 3 SPDs at 2 luminance levels l PC workstation in living room

4 Full-scale experimental rooms at University of Pannonia 1,80E 02 Reference lamps: Solux halogen 4000K CCT LED SPD: 3 SPDs at 2 luminance levels Kitchen, dining room environment e SPD [W/str*m2*nm] absolute 2,00E 02 1,60E 02 1,40E 02 1,20E 02 1,00E 02 8,00E 03 6,00E 03 4,00E 03 2,00E 03 Precise FNV/CG Q50MR16C/CG55 12,0V Precise FNV/CG Q50MR16C/CG55 12,30V 0,002 0,00E ,002 wavelength [nm] e SPD [W/str*m2*nm] absolute 0,004 0,003 0,003 0,001 0,001 Solux 4100K 0, wavelength [nm] Solux 4100K Solux 4100K

5 Full-scale experimental rooms at University of Pannonia Reference lamps: 9 x 50W halogen lamps each, 2 possible CCTs: 3000K and 4000K, Dimming i with voltage control and partitioning. i

6 Full-scale experimental rooms at University of Pannonia LED lamps: 20 independent channels (expandable to 24 channels), 24 LEDs/channel (nominal power: 480W) Controlled by 16 power supplies, each has 24 independent channels Dimming with PAM (Pulse Amplitude Modulation)

7 Luminous intensity distribution and total luminous flux of the 20 channel LED luminaire 57 cm x 57 cm luminaire Labertian luminous intensity distribution. Lamp det. distance = cm distance corr. (k1) = detector constant (k2) = lx/µa Φ v = lm Only three white channels in operation! Electrical power = W Luminous eff. η* = lm/w Diffuser decreases the lum. eff. significantly.

8 Luminous intensity distribution of the 20 channel LED luminaire 1,2 Rel. SPD of three white LED channels 57 cm x 57 cm luminaire Lambertian luminous intensity distribution. relative e SPD / sensitiv vity 1,0 0,8 0,6 0,4 0,2 Lamp det. distance = cm distance corr. (k1) = detector constant (k2) = lx/µa Φv = lm Electrical power = W Luminous eff. η* = lm/w 0, wavelength [nm] Only three white channels in operation! Diffuser decreases the lum. eff. significantly.

9 Relative spectral power distribution as the function of gamma direction Raw SPD at gamma = 0, 30, 60, 75 Max normalized SPD at gamma = 0, 30, 60, 75 1,2 1 0,8 0,6 0,4 0, C0 g0 C0 g30 C0 g60 C0 g C0 g0 C0 g30 C0 g60 C0 g75 All channels are driven at maximum power. Only small deviations in the spectral power distributions can be identified when measured from the given gamma directions.

10 Full-scale experimental rooms at University of Pannonia SPD of lights inthepilot il experiment Three light groups with different duv values (0,+, ). InonegroupthelightshaveincreasingCCTs. 0,45 y Light group A (Δuv = 0) Light group B (Δuv > 0) Light group C (Δuv < 0) AL1 AL2 AL3 AL4 AL5 BL1 BL2 BL3 BL4 CL1 CL2 CL3 CL4 X Y Z x 0,459 0,448 0,436 0,424 0,417 0,471 0,451 0,436 0,415 0,455 0,436 0,429 0,402 y 0,411 0,407 0,404 0,400 0,398 0,428 0,422 0,420 0,417 0,401 0,398 0,396 0,384 TCC 2705,0 2855,9 3004,9 3204,9 3304,9 2676,3 2909,1 3138,6 3500,8 2686,1 2964,3 3075,0 3513,6 Δuv 0, , , , , , , , , , , , , ,40 0,35 0,40 0,45 0,50 x 0duv +duv duv Planckian 0,004 0,0035 0, ,0025 0,002 0,0015 0,001 0,0005 CCT series, Δuv = K 2856 K 3005 K 3205 K 3305 K 0,01 0,009 0,008 0,007 0,006 0,005 0,004 0,003 0,002 0,001 CCT series, Δuv > K 2909 K 3139 K 3501 K 0,009 0,008 0,007 0,006 0,005 0,004 0,003 0,002 0,001 CCT series, Δuv < K 2964 K 3075 K 3514 K

11 First experimental results Observers task 1 Put the lights in the order of their general preference. A AL1 AL2 AL3 AL4 AL5 1st nd rd th th rank IV. II. I. III. V. B BL1 BL2 BL3 BL4 1st nd rd th rank II. I. IV. III. C CL1 CL2 CL3 CL4 1st nd rd th rank III. I. IV. II. Results show that the CCT region 2900 K < CCT < 3000 K is the most preferred.

12 First experimental results Observers task 2 Select the most preferable light based on the given aspects. brightness, warmness, relaxing, alertness, the most positive (+++). A AL 1 AL 2 AL 3 AL 4 AL 5 brightness warmness relaxing alertness B BL 1 BL 2 BL 3 BL 4 brightness warmness relaxing alertness Results show that there is connection between the light s CCT and the following aspects: warmness relaxing, alertness, most positive (+++). No connection between CCT and the following aspects: brightness, warmness. C CL 1 CL 2 CL 3 CL 4 brightness warmness relaxing alertness

13 Thank you for your kind attention! This research was supported by EU FP7 ICT project (grant number: ) entitled Solid State Lighting for Europe szabo.ferenc@virt.uni csuti.peter@virt.uni pannon.hu

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*

More information

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Report No.: HZ p. (Lumens) Stabilization Time CRI (K) Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

Standard-Tech Co. Ltd Testing Center

Standard-Tech Co. Ltd Testing Center Test Datasheet Test Location: [ ] 1. B802, No.11 Caipin Road, Guangzhou Science City, Guangzhou, [ ] Guangdong, China 2. R108, 1 st Floor No.69 GuangPu West Road, Guangzhou Science City, Guangzhou, Guangdong,

More information

Practical Optical Measurements of OLED Panels for Lighting Applications

Practical Optical Measurements of OLED Panels for Lighting Applications Practical Optical Measurements of OLED Panels for Lighting Applications TOKI KAWABATA KONICA MINOLTA, INC. JAPAN YOSHI OHNO National Institute of Standards and Technology U.S.A. * This work was conducted

More information

NIST Role in Supporting Solid State Lighting Initiative

NIST Role in Supporting Solid State Lighting Initiative CORM 2007 Annual Meeting, Gaithersburg, May 8-11, 2007 NIST Role in Supporting Solid State Lighting Initiative Yoshi Ohno, Ph.D. Optical Technology Division National Institute of Standards and Technology

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

PRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED

PRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED LEDVANCE FLOODLIGHT LED LED floodlight luminaires AREAS OF APPLICATION Replacement for floodlights with halogen lamps Car parks and underpasses Garages Public areas Building facades Construction areas

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 9457 lm 78.6 W 120.3 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire TESTING Report No.:BL160912008-9A NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Applicant: Maxlite.Inc Address:

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

TRNSYS MODELING OF A HYBRID LIGHTING SYSTEM: BUILDING ENERGY LOADS AND CHROMATICITY ANALYSIS

TRNSYS MODELING OF A HYBRID LIGHTING SYSTEM: BUILDING ENERGY LOADS AND CHROMATICITY ANALYSIS TRNSYS MODELING OF A HYBRID LIGHTING SYSTEM: BUILDING ENERGY LOADS AND CHROMATICITY ANALYSIS Frank W. Burkholder William A. Beckman Sanford A. Klein Doug T. Reindl University of Wisconsin-Solar Energy

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 8616 lm 70.3 W 122.6 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

LM-79 Report TEST REPORT NO. L523A

LM-79 Report TEST REPORT NO. L523A LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28

More information

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN NVLAP LAB CODE 201071-0 LM-79-08 Test Report for Forest Lighting Corporate Address: 2252 Northwest Parkway SE, Suite D, Marietta, GA 30067 LED Tube Model: FL-T8U450-15-BN Laboratory: Leading Testing Laboratories

More information

Impact of New SSL Standards on Goniospectroradiometric Measurements

Impact of New SSL Standards on Goniospectroradiometric Measurements Impact of New SSL Standards on Goniospectroradiometric Measurements By Dr. Ðenan Konjhodžić, Application Engineer Presented by Justin Blanke, International Sales Manager Outline Goniophotometry and goniophotometer

More information

Catalog # Project. Comments

Catalog # Project. Comments DESCRIPTION A LED module for use with separate control gear and suitable for field replacement. The compact light emitting surface when combined with primary optics produce tight, controlled beams of light,

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

EXPLOSION PROOF ATEX LUMINAIRE

EXPLOSION PROOF ATEX LUMINAIRE info@nextgenerationled.be www.nextgenerationled.be Tel + 32 53 71 09 42 EXPLOSION PROOF ATEX LUMINAIRE Properties n Lifespan L80 %: > 50.000 hours n Atex directive 94/9 EC n Zone 2 and 22 n IP klasse :

More information

INSPIRATION FROM NATURE

INSPIRATION FROM NATURE INSPIRATION FROM NATURE STORK LITTLE BROTHER Dimmension drawings 137 650 280 2 Main technical data Voltage, V Frequency, Hz Nominal current, ma Power, W Total luminous Flux, Lm Efficiency, Lm/W Power factor,

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.2.5 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 10 foot mounting height. REPORT NUMBER: RAB00701 ISSUE DATE: 02/04/15 PAGE: 1 OF 8 CATALOG NUMBER: VXLED26NDG / VXBRLED26NDG LUMINAIRE:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0028 STR-LWY-4M-HT-06-E-UL-XX-700-40K-XXX or BXSL0406E-UD7 PL01059-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0025 STR-LWY-2M-HT-06-E-UL-XX-700-40K-XXX or BXSL0206E-UD7 PL01056-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0019 STR-LWY-5M-HT-06-E-UL-XX-700-40K-XXX or BXSL0506E-UD7 PL01041-001 Date: 2/05/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe

2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe Lamp measurement report 16 July 2010 2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe Page 1 of 20 Summary measurement data parameter meas. result remark Color 5580 K

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W LM-79-08 Test Report For MaxLite Inc. 12 York Ave West Caldwell NJ 07006, USA LED Commercial Down lights Model: RR82540W Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09633-001A LS4-50L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

ROUNDED - SHAPED LAMPS

ROUNDED - SHAPED LAMPS 111 80 ROUNDED - SHAPED LAMPS MULTILINE is a large group of luminaires in suspended and surface-mounted version. An extensive set of standard shapes, dimensions and lighting parameters can be infinitely

More information

Main Applications MR 16 Track lighting Downlight

Main Applications MR 16 Track lighting Downlight ProLight PDSB-7FxL-BC0P 7W COB Light-Engine LEDs Technical Datasheet Version: 1.4 Features High flux density of lighting source Good color uniformity RoHS compliant Energy Star binning structure, warm

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15785 Performance Summary Luminous flux 540 lm Bare Lamp Power 7.76W SHR Nominal 0.75 SHR Maximum 0.79 PREPARED FOR : Indice Ecotech Pty. Ltd., Richmond, VIC 3121. Page 1 of 7 Performance

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO.M037D LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524

More information

Main Applications MR 16 Track lighting Candle lighting

Main Applications MR 16 Track lighting Candle lighting ProLight PDSA-6FxL-xC1x 6W COB Light-Engine LEDs Technical Datasheet Version: 1.3 Features High flux density of lighting source Good color uniformity RoHS compliant Energy Star binning structure, neutral

More information

Technology Corporation

Technology Corporation Technology Corporation ProLight PG1M-3LXP-3SC 9W Power LED Module Technical Datasheet Version: 1.1 Features High flux per LED Very long operating life(up to 1k hours) Various colors Good color uniformity

More information

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS 71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08254-001A S-DL4-A-42L-40K-W w_s-dl4t-a-ssc Date: 04/27/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Test report of IES LM Approved Method: Electrical and Photometric

Test report of IES LM Approved Method: Electrical and Photometric NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Date of issue 2016-05-17 Version 1.0 Total pages 16 Applicant:

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo SLM PW L06 15 G7 Datasheet Experience bright and vivid colors Fortimo LED SLM PW L06 15 G7 Fortimo LED SLM Gen7 continues to focus on the combination of Quality of Light and performance.

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Product Description. MASTERColour CDM-T. Benefits. Features. Application. Versions

Product Description. MASTERColour CDM-T. Benefits. Features. Application. Versions Lighting Product Description Range of single-ended, compact, high-efficiency, discharge lamps with a stable colour over lifetime and a crisp, sparkling light Benefits Stable colour impression over lifetime

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542991XX(XX:41-50) Laboratory: Leading Testing

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542961XX(XX:41-50) Laboratory: Leading Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000795-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 35087 lm 296.1 W 118.5 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09300-001A ARE-EHO-3M-xx-12-E-UL-xx-1000-xxxx Date: 09/16/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.005.01.02 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 16 foot mounting height..002 REPORT NUMBER: RAB01042 ISSUE DATE: 07/15/15 PAGE: 1 OF 8 DATE SAMPLE TESTED: 07/15/15 CATALOG NUMBER:

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

Measurement method for the proficiency testing program

Measurement method for the proficiency testing program APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Key objectives in Lighting design

Key objectives in Lighting design Key objectives in Lighting design Visual performance Physiological conditions Visual quality no strong "contrasts" good "color rendering" adequate "light levels" no "disturbing reflections" no direct "glare"

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,

More information

Uncertainty determination of correlated color temperature for high intensity discharge lamps.

Uncertainty determination of correlated color temperature for high intensity discharge lamps. Uncertainty determination of correlated color temperature for high intensity discharge lamps A.B. El-Bialy 1, M.M. El-Ganainy 2 and E.M. El-Moghazy 3 1 University College for Woman for Art, science and

More information

Cove Light AC HO / HO Graze

Cove Light AC HO / HO Graze Date: Quantity: Company: Project: Cove Light AC HO / HO Graze The Cove Light AC HO offers a range of cold, neutral, or warm white with a 120x120 degree beam angle for general lighting, wall washing, and

More information

Optical differentiation with third party lenses

Optical differentiation with third party lenses Fortimo LED FastFlex 2x6 DA G Datasheet Optical differentiation with third party lenses FastFlex 2x6 DA G Applications Road lighting Urban street lighting Flood and Area lighting Tunnel lighting High bay

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

B V-180-8mm-14.5W-2700K-IP68

B V-180-8mm-14.5W-2700K-IP68 Tpe Qt B3528-24V-18-8mm-14W-XXK-IPYY Specification Sheet PHYSICAL Product Tpe Flexible LED Strip SMD Tpe 3528 Strip Width 5/16 in 8 mm Strip Total Length (Roll) 16 ft 5 m LED Linear Densit 54 LED/ft 18

More information

Lighting Sciences

Lighting Sciences Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT BEAM SIDE LUMENS

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

Uncertainty determination of correlated color temperature for high intensity discharge lamps

Uncertainty determination of correlated color temperature for high intensity discharge lamps Uncertainty determination of correlated color temperature for high intensity discharge lamps A.B. El-Bialy 1, M.M. El-Ganainy 2 and E.M. El-Moghazy 3 1 University College for Woman for Art, science and

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

B V-120-8mm-9.6W-2700K-IP68

B V-120-8mm-9.6W-2700K-IP68 Tpe Qt B3528-12V-12-8mm-9W-XXK-IPYY Specification Sheet PHYSICAL Product Tpe Flexible LED Strip SMD Tpe 3528 Strip Width 5/16 in 8 mm Strip Total Length (Roll) 16 ft 5 m LED Linear Densit 36 LED/ft 12

More information