Bull. Chem. Soc. Ethiop. 2012, 26(1), ISSN Printed in Ethiopia
|
|
- Opal Quinn
- 5 years ago
- Views:
Transcription
1 , ISSN Printed in Ethiopia 2012 Chemical Society of Ethiopia DOI: SOLID PHASE EXTRACTION OF TRACE AMOUNTS OF PALLADIUM IONS USING MULTIWALLED CARBON NANOTUBE MODIFIED BY N,N -BIS (2-HYDROXY- BENZYLIDENE)-2,2 (AMINOPHENYLTHIO) ETHANE PRIOR TO DETERMINATION BY FLAME ATOMIC ABSORPTION SPECTROMETRY T. Shamspur 1,2* 1 Chemistry Department, Shahid Bahonar University, Kerman, Iran 2 Nanochemistry groups, Shahid Bahonar University, Kerman, Iran (Received December 14, 2010; revised May 16, 2011) ABSTRACT. Multiwalled carbon nanotubes modified with N,N -bis(2-hydroxybenzylidene)- 2,2 (aminophenylthio) ethane have been developed for the selective separation and/or preconcentration of trace amounts of Pd(II) in aqueous medium. Parameters including ph of aqueous solution, flow rates, the amount of ligand and the type of stripping solvents were optimized. It was found that the sorption is quantitative in the ph range (1.5-4), whereas quantitative desorption occurs instantaneously with 3.0 ml of 0.3 M Na 2SO 3. Linearity was maintained between 0.01 to 22 µg ml -1 for Pd in the final solution. The breakthrough volume was greater than 1800 ml with an enrichment factor of more than 600 and 6.0 µg L 1 detection limit (3s, n = 10). The effects of various ions interferences on the percent recovery of palladium ion were studied. The method was successfully applied to the determination of palladium ion in environmental samples. KEY WORDS: Multiwalled carbon nanotubes, Preconcentration, Palladium(II) determination INTRODUCTION Palladium is a metal of economic importance due to its extensive use in metallurgy, in various chemical syntheses, production of dental and medicinal devices and in jewellery manufacture [1]. This metal may enter the environment and interact with complexing materials, such as humic substances [2]. Palladium has no biological role and all palladium compounds should be regarded as highly toxic and carcinogenic. However, palladium chloride was formerly prescribed as a treatment for tuberculosis without too many bad side effects. There is currently much discussion about its bioavailability and toxicology [3]. Thus, due to its increasing use, on the one hand, and the toxicity of Pd(II) compounds to mammals, fish and higher plants, on the other hand, the separation and determination of palladium is of special interest in environmental analysis. Low concentration of Pd in industrial (µg g 1 level) and environmental samples (ng g 1 level) together with the complexity of the matrix cause much interference during the determination of palladium. Therefore, the application of highly sensitive techniques, such as flame atomic absorption spectrometry (FAAS) [4, 5], graphite furnace atomic absorption spectrometry (GFAAS) [6, 7], inductively coupled plasma-atomic emission spectrometry ICP- AES [8, 9], inductively coupled plasma mass spectrometry ICP-MS [10, 11], coupled with a separation and enrichment procedure is necessary [12-14]. Typically, solid-phase extraction (SPE) replaces liquid-liquid extraction as a sample preparation tool and provides a method that is simple and safe to use. The benefits of SPE include high recoveries of analytes, purified extracts, high preconcentration factors, ease of automation, and reduction in the consumption of organic solvents [15, 16]. The methods for producing solid phase material for SPE include binding the metal ion with chelating agents and adsorption on a solid phase such as octadecylsilane [17, 18], and using chemically bonded silica gel [19, 20], activated carbon [21, 22], ion-exchange resins [23, 24], chelating resins [25, 26], zeolites [27-29] and various polymers [30]. *Corresponding author. shamspur@gmail.com
2 20 T. Shamspur Recently, carbon nanotubes (CNTs) [31, 32] have been used for the extraction and analysis of many different organic and environmental matrices. Moreover, these sorbents modified by suitable ligands, are successfully used for the separation and sensitive determination of metal ions [32-36]. In general, Schiff ligands are among the oldest ligands in coordination chemistry [37]. The Schiff bases derived from salicylaldehyde (salen) as polydentate ligands are known to form very stable complexes with transition metal ions [38, 39]. In the present investigation, the analytical potential of multiwalled carbon nanotubes (MWCNTs) modified with N,N -bis(2-hydroxybenzylidene)-2,2 (aminophenylthio) ethane (NBHAE) (Figure 1) was examined for preconcentration of Pd(II) in aqueous samples prior to its flame atomic absorption spectrometric determination. The analytical conditions for the preconcentration (quantitative retentions) of analyte were investigated. Figure 1. Structure of N,N`-bis(2-hydroxybenzylidene)-2,2`(aminophenylthio) ethane (NBHAE). Apparatus EXPERIMENTAL The palladium measurement was performed with a Varian Spectr AA220 atomic absorption spectrometer (Australia) equipped with a computer processor. A palladium hollow cathode lamp, operated at 5 ma, was utilized as the radiation source. The analytical wavelength (363.5 nm) and slit width (0.1 nm) were used as recommended by manufacturers. The ph values were measured with a metrohm 827 ph meter (Herisau, Switzerland) supplied with a combined glass electrode. A funnel-tipped glass tube (80 5 mm) was used as column for preconcentration. All glassware and columns were washed with mixture of concentrated hydrochloric acid and concentrated nitric acid (1:1) before use. Reagents and materials All the reagents used were of the highest purity available and at least of analytical reagent grade. The stock solution of Pd(II) (100 µg ml 1 ) was prepared by dissolving the proper amount of Pd(CH 3 COO) 2 from Merck (Darmstadt, Germany) in 2 mol L -1 hydrochloric acid solution. Standard solutions of Pd(II) were prepared daily by appropriate dilution of palladium stock solution. Stock solution of diverse elements was prepared from high purity compounds. Multiwalled carbon nanotubes of 95% purity and length 1-10 µm, number of walls 3-15 were purchased from Plasma Chem. GmbH (Germany). The Schiff base ligand NBHAE was synthesized and purified as reported in the literature [40]. A 0.2% (m/v) solution of NBHAE was prepared by dissolving of 50 mg of NBHAE in 1.0 ml of DMF and diluting to 25.0 ml with ethanol.
3 Solid phase extraction of trace amounts of Pd(II) using multiwalled carbon nanotube 21 Preparation of modified MWCNTs Prior to use, MWCNTs materials were oxidized with concentrated HNO 3 according to literature with minor modification [32]. In order to create binding sites onto the surface, 3.0 g of MWCNTs were first soaked in 30 ml of concentration HNO 3 for 12 h at room temperature while being stirred [41]. Then the solution was filtered through a 0.45 µm membrane filter and the MWCNTs were washed with distilled water until the ph was neutral. 2 g of MWCNTs was suspended in 20 ml 0.2% (m/v) solution of NBHAE and the mixture was refluxed with stirring for 4 h. The solid was filtered, washed with water and dried at 80 C. The amount of NBHAE deposited on the MWCNTs was estimated by spectrometric measurements from the residual amount of NBHAE in solution. Column preparation An aliquot 40.0 mg of modified MWCNTs was slurred in water, and then poured into a funneltipped glass tube (80 5 mm) plugged with a small portion of cotton at ends. The column could be used repeatedly after washing with distilled water. Recommended procedure Fifty milliliters of an aqueous solution containing 5.0 µg of Pd(II) was taken and the ph was adjusted to about 2. The resulting solution was passed through the column at flow rate of about 1 ml min -1. After passing of solution completely, the column was rinsed with 5 ml of water and the adsorbed ions were eluted with 3.0 ml 0.3 M Na 2 SO 3 with a flow rate of 1 ml min -1. The Pd(II) in the eluent were determined by FAAS. RESULTS AND DISCUSSION Some preliminary experiments were carried out in order to investigate the quantitative retention of Pd(II) ions by MWCNTs in the absence and presence of NBHAE. Experimental results showed that MWCNTs have a tendency for the retention of metal ions adsorption (<40 % for Pd 2+ ) but were not selective. Modified multiwalled carbon nanotube with NBHAE has a greater capacity of adsorption and selectivity of ions. In order to achieve the best performance, the separation/preconcentration procedure was optimized for various analytical parameters, such as, the nature and concentration of eluent, ph of the sample solution, volume and type of the eluent solution, the flow rate of eluent and sample solutions and volume of the sample solution. Various ions interferences effects were also investigated. Choice of eluent One of the important factors that affect the preconcentration procedure is the type, volume and concentration of the eluent used for the removal of metal ions from the sorbent [42]. In order to choose the most effective eluent for the quantitative stripping of the retained Pd(II) ions by the modified column MWCNTs with NBHAE, after the extraction from 50 ml water (ph 2), the Pd(II) were stripped with 3 ml of various stripping agents. The results are summarized in Table 1. Results showed that the elution of the retained Pd(II) was quantitative with Na 2 SO 3. The effect of varying concentration of Na 2 SO 3 on the recovery of Pd(II) was also studied and the results are included in Table 1. As can be seen, 3 ml of 0.3 M Na 2 SO 3 solution can accomplish the quantitative elution of Pd(II) from the modified column.
4 22 T. Shamspur Table 1. Percent recovery of Pd(II) from the modified column as a function of stripping solutions a. Stripping agent Recovery (%) b HCl (0.1 M) 92.0 ± 0.5 Thiourea 89.1±0.6 Na 2S 2O ± 0.5 KSCN 64.3±1.0 Na 2SO 3 (0.1 M) Na 2SO 3 (0.3 M) Na 2SO 3 (0..5 M) 98.0± ± ±0.5 a Initial samples contained 5.0 µg Pd(II) in 50 ml water. b Average of four determinations ± standard deviation. Effect of the sample ph One of the most important parameters affecting the preconcentration procedure is the ph of the solution, because the formation of soluble metal complexes and their stabilities in aqueous solutions are strongly related to the ph of the medium [43, 44]. The influence of ph on the recovery of Pd(II) was examined in the ph range of 1-10 (Figure 2). It was found that the sorption is quantitative in the ph range ( ). Therefore the ph was adjusted to about 2 for subsequent experiments. Figure 2. Effect of ph of sample solution on the recovery of Pd(II). Effect of flow rates of sample and eluent solution The retention of an element on an adsorbent also depends on the flow rate of the sample solution [42]. Thus, the effect of flow rates of the sample and elution solutions on the retention and recovery of ions was investigated under optimum conditions. It was found that retention and recovery of the ions was independent of flow rate in a range of ml min -1. Therefore a flow rate of 1 ml min -1 was applied for sample and elution solutions in all subsequent experiments. Breakthrough volume The measurement of breakthrough volume is important in solid-phase extraction because breakthrough volume represents the sample volume that can be preconcentrated without loss of analyte during elution of the sample [42]. The breakthrough volume is strongly dependent on the nature of both the sorbent and the trace element, as well as on the mass of sorbent considered and the analyte concentration in the sample [45]. In addition, it depends on the sorbent containers, as discs usually offer higher breakthrough volumes than cartridges. The
5 Solid phase extraction of trace amounts of Pd(II) using multiwalled carbon nanotube 23 breakthrough volume of sample solution was tested by dissolving 5.0 µg Pd(II) in 50, 100, 500, 1000, 1500, 1800 and 2000 ml water and the recommended procedure was followed under optimal experimental conditions. In all cases to 1800 ml the extraction by the column was found to be quantitative. Thus, the breakthrough volume for the method should be greater than 1800 ml. Consequently, by considering the final elution volume of 3.0 ml and the breakthrough volume of 1800 ml, an enrichment factor of 600 was easily achievable. Adsorption capacity The adsorption capacity is the maximum metal quantity taken up by 1 g of solid phase and given by mg metal g 1 modified solid phase [46]. The adsorption capacities of modified column were determined by batch and column methods. Batch method Fifty milliliters of solution containing 4.0 mg of palladium at ph 2 was added to 40.0 mg sorbent. After shaking for 30 min, the mixture was filtered. A 10.0 ml aliquot of the supernatant solution was diluted to ml and determined by FAAS. The capacity of sorbent for Pd(II) was found 86 mg g -1. Column method In addition the sorption capacity of the column was determined by passing 40.0 ml of µg ml -1 of Pd(II) at ph 2 through the column, followed by the determination of the retained ions using atomic absorption spectrometry. The maximum capacity of the sorbent for Pd(II) was found 98 mg g -1. Analytical performance Calibration curve was constructed for the determination of Pd(II) according to the general procedure under the optimized conditions. Linearity was maintained between µg ml -1 in the final solution with a correlation factor of (A = C ). The limits of detection (LOD) based on three times the standard deviation of the blank (3S b ) [47] under optimal experimental conditions was 6.0 µg L 1 (n = 10). The reproducibility of the proposed method for the extraction and determination of 5.0 mg of Pd(II) from 50 ml of water was also studied. The obtained RSD in 10 replicate measurements was 2.43%. Matrix effects Matrix effects are important problem in the determination of metals in real samples [48, 49]. In order to assess the possible analytical applications of the recommended procedure, the interference due to several cations and anions was examined under optimized conditions. For these studies an aliquot of aqueous solution (50 ml) containing 5.0 µg of Pd(II) was taken with different amounts of foreign ions and the procedure was implemented. The tolerance limit was defined as the highest amount of foreign ions that produced an error no greater than ±3% in the determination of investigated palladium ions. The results are summarized in Table 2. The results show that the proposed method is selective and can be used for determination of Pd(II) in various samples without interference.
6 24 T. Shamspur Table 2. Effect of interfering ions a. Coexisting ions Ion concentration/pd concentration Coexisting ions Ion concentration/pd concentration Mg 2+, Ca ClO Na + +, NH 4, K b Cd(II) 1100 CH 3COO - -, NO b Pb(II) 890 EDTA 500 Zn(II) 800 Tartrate 650 Co(II) 600 Oxalate 700 Rh(III) H 2PO Mn(II) HPO Au(III) SO Cu(II) CO Ni(II) PO Fe(III) 950 a Conditions: Initial samples contained 5.0 µg Pd 2+ and different amounts of various ions in 50 ml water. b Above which was not tested. Accuracy and applications In order to assess the applicability of the method to real samples with different matrices containing varying amount of a variety of diverse ions it was applied to the separation and recovery of Pd(II) ions from two different synthetic and three water samples. According to the results, the concentration of Pd(II) in analyzed water samples was below the LOD of the method. The suitability of the proposed method for the analysis of water samples was checked by spiking samples with 5.0 and 10.0 µg ml 1 of Pd(II). Good recoveries (96-102%) were achieved for all analyzed samples. The data obtained with the proposed method were presented in Table 3. The results indicate that the proposed method can be reliably used for the determination of palladium in various matrices. Table 3. Determination of Pd(II) in water and synthetic samples. Sample Spiked (µg ml -1 ) Found (µg ml -1 ) Recovery (%) Well water (Shahid Bahonar University) - N.D b ± ± Tap water (Kerman drinking water) - N.D ± ± Synthetic sample 1 c ± Synthetic sample 2 d ± a Average of four determinations ±standard deviation. b Not detected. c Zn 2+, Cd 2+, Ni 2+, Pb 2+, Ba 2+, Fe 3+, Hg 2+, Co 2+, Cu 2+, 1 mg of each cation. d Mg 2+, Ca 2+, Na +, NH 4 +, K +, Zn 2+, Cd 2+, Ni 2+, Pb 2+, Ba 2+, Fe 3+, Hg 2+, Co 2+, Cu 2+, 3 mg of each cation. Comparison of this method with other methods Several methods have been reported in the literature for the preconcentration and determination of palladium. Some characteristics of previously reported methods such as enrichment factor and LOD are summarized in Table 4 for comparison. As can be seen, the proposed SPE method in this work, for the preconcentration of Pd(II), shows a high enrichment factor to the previously reported methods. In addition, its low cost and simplicity as well as its high selectivity for Pd(II)
7 Solid phase extraction of trace amounts of Pd(II) using multiwalled carbon nanotube 25 make it as a suitable quantitative determination method. The method was successfully applied to the determination of trace amount of palladium in water samples with excellent recoveries. Table 4. Comparison of the published preconcentration methods for Pd with the proposed method. Preconcentration method Determination method Enrichment factor Detection limit (µg L -1 ) Linear range (µg L -1 ) Reference SPE FAAS [35] DLLME a FAAS [50] DLLME GFAAS [51] SFODME based on USD b FAAS [5] SPE FAAS This work a Dispersive liquid-liquid microextraction. b Solidified floating organic drop microextraction based on ultrasounddispersion. CONCLUSIONS Palladium can be determined successfully by using the proposed separation/preconcentration method in the presence of high concentrations of matrix ions. The proposed method is simple, precise and accurate. Recovery values obtained are in the range % which demonstrates the applicability of the method and indicates that the method is essentially free from interferences for a large number of diverse ions, which are associated with Pd in its natural occurrence and industrial samples. Due to relative high preconcentration factor, trace metal ion at ppb level can be determined by this proposed method. The use of organic solvents in the proposed method is eliminated. The reproducibility of the method is at the most 2.43%. The method is economical and during the step of desorption the ligand remains in the modified column, which allows using the column more than once. ACKNOWLEDGEMENTS This paper is dedicated to the memory of the founder of Kerman University, Mr. Alireza Afzalipour. REFERENCES 1. Zyłkiewicz, B.G.; Kozłowska, M. Anal. Chim. Acta 2005, 539, Hees, T.; Wenclawiak, B.; Lusting, S.; Schramel, P.; Schwarzer, M.; Schuster, M.; Verstraete, D.; Dams, R.; Hemers, E. Environ. Sci. Pollut. Res. 1998, 5, Lee, S.D. Biochemical Aspects of Environmental Pollutants, Ann Arbor Science Publishers: Ann Arbor; Praveen, R.S.; Daniel, S.; Prasada Rao, T.; Sampath, S.; Sreenivasa Rao, K. Talanta 2006, 70, Mohamadi, M.; Mostafavi, A. Talanta 2010, 81, Kovacheva, P.; Djingova, R. Anal. Chim. Acta 2002, 464, Wu, Y.; Hu, B.; Jiang, Z.; Chen, Sh. J. Anal. At. Spectrom. 2002, 17, Benkhedda, K.; Dimitrova, B.; Infante, H.G.; Ivanova, E.; Adoms, F.C. J. Anal. At. Spectrom. 2003, 18, Moldovan, M.; G omez, M.M.; Palacios, M.A. Anal. Chim. Acta 2003, 478, Bencs, L.; Ravindra, K.; Van Grieken, R., Spectrochim. Acta B 2003, 58, Zyłkiewicz, B.G. Microchim. Acta 2004, 147, 189.
8 26 T. Shamspur 12. Jarvis, I.; Totland, M.M.; Jarvis, K.E. Analyst 1997, 122, Bencs, L.; Ravindra, K.; Grieken, R.V. Spectrochim. Acta B 2003, 58, Ek, K.H.; Morrison, G.M.; Rauch, S. Sci. Total Environ. 2004, 21, Garg, B.S.; Bist, J.S.; Sharma, P.K.; Bhojakm, N. Talanta 1996, 43, Izatt, R.M.; Bradshaw, J.S.; Bruening, R.L. Pure Appl. Chem. 1996, 68, Shamspur, T.; Mostafavi, A.; Sheikhshoaie, I. J. AOAC Int. 2008, 91, Shamspur, T.; Mashhadizadeh, M.H.; Sheikhshoaie, I. J. Anal. At. Spectrom. 2003, 18, Tokman, N.; Akman, S.; Ozcan, M. Talanta 2003, 59, Ngeontae, W.; eungmaitrepirom, W.A.; Tuntulani, T. Talanta 2007, 71, Kimura, M.; Kawanami, K. Talanta 1979, 26, Ferrua, N.; Cerutti, S.; Salonia, J.A.; Olsina, R.A.; Martinez, L.D. J. Hazard. Mater. 2007, 141, Carrero, P.E.; Tyson, J.F. Analyst 1997, 122, Nabi, S.; Alim, A.; Islam, A.; Amjad, M. J. Sep. Sci. 2005, 28, Madrakian, T.; Afkhami, A.; Esmaeili, A.Talanta 2003, 60, Seyhan, S.; Colak, M.; Merdivan, M.; Demirel, N. Anal. Chim. Acta 2007, 584, Afzali, D.; Mostafavi, A.; Taher, M.A.; Moradian, A. Talanta 2007, 71, Shamspur, T.; Mashhadizadeh, M.H.; Sheikhshoaie, I. J. Anal. At. Spectrom. 2005, 20, Shamspur, T.; Mostafavi, A. J. AOAC Int. 2009, 92, Sabermahani, F.; Taher, M.A. Anal. Chim. Acta 2006, 565, Zhou, Q.X.; Xiao, J.P.; Wang, W.D.; Liu, G.G.; Shi, Q.Z.; Wang, J.H. Talanta 2006, 68, Shamspur, T.; Mostafavi, A. J. Hazard. Mater. 2009, 168, Khorrami, A.R.; Naeimi, H.; Fakhari, A.R. Talanta 2004, 64, Mashhadizadeh, M.H.; Shamspur, T.; Sheikhshoaie I. Asian J. Chem. 2006, 18, Farhadi, K.; Teimouri, G. Talanta 2005, 65, Tuzen, M.; Soylak, M. J. Hazard. Mater. 2007, 147, Razee, S.; Masujima, T. Anal. Chem. Acta 2002, 464, Alizadeh, N.; Ershad, S.; Naeimi, H.; Sharghi, H.; Shamsipur, M. Polish J. Chem. 1999, 73, Shamsipur, M.; Ghiasvand, A.R.; Sharghi, H.; Naeimi, H. Anal. Chim. Acta 2000, 408, Barbosa, A.F.; Segatelli, M.G.; Pereira, A.C.; Santos, A.S.; Kubota, L.T.; Luccas, P.O.; Tarley, C.R.T. Talanta 2007, 71, Li, Q.L.; Yuan, D.X.; Lin, Q.M. J. Chromatogr. A 2004, 1026, Mester, Z.; Sturgeon, R. Sample Preparation for Trace Element Analysis, Elsevier: Amsterdam; Tokalıo glu, S.; Oymakb, T.; Kartal, S. Anal. Chim. Acta 2004, 511, Tuzen, M.; Soylak, M. J. Hazard. Mater. 2006, 129, Hennion, M.C. Trends Anal. Chem. 1991, 10, Ghaedi, M.; Shokrollahi, A.; Kianfar, A.H.; Pourfarokhi, N.; Khanjari, A.; Mirsadeghi, A.S.; Soylak, M. J. Hazard. Mater. 2009, 162, Miller, J.C.; Miller, J.N. Statistics for Analytical Chemistry, Ellis Harwood: Chichestor; He, Q.; Chang, X.; Huang, X.; Hu, Z. Microchim. Acta 2008, 160, Bag, H.; Elci, A.; Elci, L. J. Anal. Chem. 2006, 1, Kokya, T.A.; Farhadi, K. J. Hazard. Mater. 2009, 169, Liang, P.; Zhao, E.; Li, F.Talanta 2009, 77, 1854.
Flame atomic absorption spectrometric determination of trace amounts of Pb (II) after soild phase extraction using multiwalled carbon nanotube
International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol. 3, No.3, pp 1635-1640, July-Sept 2011 Flame atomic absorption spectrometric determination of trace amounts of Pb (II)
More informationApplication of Modified Nanoclay Sorbent for Separation and Preconcentration Trace Amount of Cobalt
Int. J. Nanosci. Nanotechnol., Vol. 7, No. 1, Mar. 2011, pp. 21-27 Application of Modified Nanoclay Sorbent for Separation and Preconcentration Trace Amount of Cobalt D. Afzali *1, Z. Biniaz 2, A. Mostafavi
More informationDetermination of Iron by Dispersive Liquid-Liquid Microextraction Procedure in Environmental Samples
American Journal of Chemistry 2012, 2(1): 28-32 DOI: 10.5923/j.chemistry.20120201.07 Determination of Iron by Dispersive Liquid-Liquid Microextraction Procedure in Environmental Samples F. Sánchez Rojas
More informationDetermination of Some Heavy Metals in Real Samples by FAAS after Preconcentration on 4-Nitro-2-(2-nitrophenelazo)phenol
Chem Sci Trans., 2012, 1(3), 530-537 Chemical Science Transactions DOI:10.7598/cst2012.168 ISSN/E-ISSN: 2278-3458/2278-3318 RESEARCH ARTICLE Determination of Some Heavy Metals in Real Samples by FAAS after
More informationSupplementary Material (ESI) for Journal of Analytical Atomic Spectrometry This journal is The Royal Society of Chemistry 2010
Magnetic Solid Phase Microextraction on a Microchip Combined with Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry for Determination of, and in Cells Beibei Chen 1, Shujing Heng
More informationJournal of Hazardous Materials
Journal of Hazardous Materials 181 (2010) 957 961 Contents lists available at ScienceDirect Journal of Hazardous Materials journal homepage: www.elsevier.com/locate/jhazmat Preconcentration of gold ions
More informationSodium Chloride - Analytical Standard
Sodium Chloride - Analytical Standard Determination of Total Mercury Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-106-1994 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes
More informationPRECONCENTRATION AND EXTRACTION OF COPPER(II) ON ACTIVATED CARBON USING ETHYL-2-QUINOLYL-β(p-CARBOXYPHENYL HYDRAZONE)DIOXO PROPIONATE
, 331-338. ISSN 1011-3924 Printed in Ethiopia 2008 Chemical Society of Ethiopia PRECONCENTRATION AND EXTRACTION OF COPPER(II) ON ACTIVATED CARBON USING ETHYL-2-QUINOLYL-β(p-CARBOXYPHENYL HYDRAZONE)DIOXO
More informationLEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION
LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION TRAJČE STAFILOV, GORICA PAVLOVSKA AND KATARINA ČUNDEVA Institute
More informationCHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS
Islamic University in Madinah Department of Chemistry CHAPTER - ----- CHROMATOGRAPHIC METHODS OF SEPARATIONS Prepared By Dr. Khalid Ahmad Shadid Chemistry Department Islamic University in Madinah TRADITIONAL
More informationBull. Chem. Soc. Ethiop. 2013, 27(2), ISSN Printed in Ethiopia
, 161-168. ISSN 1011-3924 Printed in Ethiopia 2013 Chemical Society of Ethiopia DOI: http://dx.doi.org/10.4314/bcse.v27i2.1 COMBINATION OF FLAME ATOMIC ABSORPTION SPECTROMETRY WITH LIGANDLESS-DISPERSIVE
More informationNota Técnica. Quim. Nova, Vol. 35, No. 1, , 2012
Quim. Nova, Vol. 35, No. 1, 198-202, 2012 Nota Técnica DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOR THE SIMULTANEOUS SEPARATION OF TRACE AMOUNTS OF ZINC AND CADMIUM IONS IN WATER SAMPLES PRIOR TO FLAME
More informationGRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM AFTER SOLID-LIQUID EXTRACTION WITH DITHIZONE
, 257-261. ISSN 1011-3924 Printed in Ethiopia 2009 Chemical Society of Ethiopia SHORT COMMUNICATION GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM AFTER SOLID-LIQUID EXTRACTION
More informationSupporting Information. Facile design of phase separation for microfluidic. droplet-based liquid phase microextraction as a front end to
Supporting Information Facile design of phase separation for microfluidic droplet-based liquid phase microextraction as a front end to electrothermal vaporization-icpms for the analysis of trace metals
More informationPointH Standard Addition Method for Simultaneous Determination of Zinc (II) and Aluminum (III) Ions
Advances in Analytical Chemistry 2014, 4(1): 13-19 DOI: 1923/j.aac.20140403 PointH Standard Addition Method for Simultaneous E. A. Basher *, M. A. Z. El Tayeb Department of Chemistry, Faculty of Science
More informationAnalytica Chimica Acta 452 (2002) Received 20 September 2000; received in revised form 14 August 2001; accepted 26 September 2001
Analytica Chimica Acta 452 (2002) 77 83 Column solid-phase extraction with Chromosorb-102 resin and determination of trace elements in water and sediment samples by flame atomic absorption spectrometry
More informationISSN: ; CODEN ECJHAO E-Journal of Chemistry , 8(2),
ISSN: 0973-4945; CODEN ECJHAO E-Journal of Chemistry http://www.e-journals.net 2011, 8(2), 587-593 Third Derivative Spectrophotometric Method for Simultaneous Determination of Copper and Nickel Using 6-(2-Naphthyl)-2,
More informationRemoval of Cu 2+, Cd 2+, Hg 2+, and Ag + from Industrial Wastewater by Using Thiol-Loaded Silica Gel
Universities Research Journal 2011, Vol. 4, No. 3 Removal of Cu 2+, Cd 2+, Hg 2+, and Ag + from Industrial Wastewater by Using Thiol-Loaded Silica Gel Aye Aye Myat 1, Kyaw Naing 2 and San San Myint 1 Abstract
More informationMOF-76: From Luminescent Probe to Highly Efficient U VI Sorption Material
MOF-76: From Luminescent Probe to Highly Efficient U VI Sorption Material Weiting Yang, a Zhi-Qiang Bai, b Wei-Qun Shi*, b Li-Yong Yuan, b Tao Tian, a Zhi-Fang Chai*, c Hao Wang, a and Zhong-Ming Sun*
More informationSolid Phase Extraction of Trace Cu(II), Mn(II), Pb(II) and Zn(II) in Water Samples with Pulverized Silica-salen(NEt 2 ) 2
Solid Phase Extraction with Pulverized Silica-salen(NEt 2 ) 2 Bull. Korean Chem. Soc. 2006, Vol. 27, No. 10 1557 Solid Phase Extraction of Trace Cu(II), Mn(II), Pb(II) and Zn(II) in Water Samples with
More informationCL Resin based methods for the separation and determination of Cl-36 and I-129 in environmental and decommissioning samples
CL Resin based methods for the separation and determination of Cl-36 and I-129 in environmental and decommissioning samples Outline Scope Resin characterization Method optimization Spiked samples Summary
More informationTest Method: CPSC-CH-E
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 10901 DARNESTOWN RD GAITHERSBURG, MD 20878 Test Method: CPSC-CH-E1001-08 Standard Operating Procedure
More informationNICKEL-63/59 IN WATER
Analytical Procedure NICKEL-63/59 IN WATER 1. SCOPE 1.1. This is a method for the separation and measurement of nickel- 63/59 in water samples. 1.2. This method does not address all aspects of safety,
More information2-Hydroxy-4-n-propoxy-5-bromoacetophenone (HnPBAO) oxime as a gravimetric reagent for Ni(II) and Cu(II) and spectrophotometric study of the complexes
Available online at www.pelagiaresearchlibrary.com Pelagia Research Library Der Chemica Sinica, 2010, 1 (3): 100-106 ISSN: 0976-8505 CODEN (USA) CSHIA5 2-Hydroxy-4-n-propoxy-5-bromoacetophenone (HnPBAO)
More informationProf. Dr. Biljana Škrbić, Jelena Živančev
5 th CEFSER Training Course Analysis of chemical contaminants in food and the environment Faculty of Technology, University of Novi Sad, Novi Sad, Republic of Serbia 7-11 May 2012 Analysis of heavy elements
More informationNanoparticles as a Sorbent for Preconcentration and Determination of Ultra-Trace Palladium Ions
Current World Environment Vol. 7(2), 227-232 (2012) Pyridine-Functionalized TiO 2 Nanoparticles as a Sorbent for Preconcentration and Determination of Ultra-Trace Palladium Ions MOHAMMAD KARIMI 1, MONA
More informationMehrorang Ghaedi 1* and Ebrahim Niknam 1. (Received January 29, 2009; revised May 31, 2009)
, 11-20. ISSN 1011-3924 Printed in Ethiopia 2010 Chemical Society of Ethiopia APPLICATION OF TRITON X-100 COATED POLY VINYL CHLORIDE AS NEW SOLID PHASE FOR PRECONCENTRATION OF Fe 3+, Cu 2+ AND Zn 2+ IONS
More information12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))
12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP)) O - O - O N + O N + O N NH N H N H O 1,3-bis(4-nitrophenyl)urea, 4,6-dimethyl-1H-pyrimidin-2-one C 13
More informationLIU ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 86, NO. 4,
LIU ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 86, NO. 4, 2003 839 RESIDUES AND TRACE ELEMENTS Interference-Free Determination of Trace Levels of Gold and Palladium in Geological and Metallurgical Samples
More informationAuthors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin
Elemental Scientific prepfast IC: Inline Autodilution Method to Eliminate Species Interconversion for LC-ICPMS Based Applications Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan
More informationREMOVAL OF NICKEL(II) AND PALLADIUM(II) FROM SURFACE WATERS. (Received February 1, 2012; revised July 13, 2012) INTRODUCTION
, 15-23. ISSN 1011-3924 Printed in Ethiopia 2013 Chemical Society of Ethiopia DOI: http://dx.doi.org/10.4314/bcse.v27i1.2 REMOVAL OF NICKEL(II) A PALLADIUM(II) FROM SURFACE WATERS Fatemeh Sabermahani 1,2*,
More informationMajid Ramezani *, Mohsen Heidarzadeh, Fatemeh Yousefi 1. INTRODUCTION. J. Iranian Chem. Res. 5 (4) (2012) ISSN
J. Iranian Chem. Res. 5 (4) (2012) 281-289 ISSN 2008-1030 Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic
More informationDirect Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS
Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS Application Note Semiconductor Authors Junichi Takahashi Agilent Technologies Tokyo, Japan Abstract Ammonium hydroxide
More informationISSN : Department of Toxicology, School of Veterinary Medicine, University of Tehran, Tehran, (IRAN) 2
Trade Science Inc ISSN : 0974-7419 Volume 10 Issue 8 ACAIJ, 10(8) 2011 [522-526] Separation and preconcentration of aluminium by float precipitate formation/flocculation and determination with flame atomic
More informationFractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)
Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX) Application Note Forensic Toxicology Authors Bellah. Pule,
More informationMETHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY
METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY 1.0 SCOPE AND APPLICATION 1.1 This digestion procedure is used for the preparation
More informationHossein Tavallali 1 *, Vahid Fakhraee 2. I.R. of IRAN. Omidiyeh branch, Omidiyeh, IRAN. *Corres.author:
International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol. 3, No.3, pp 1628-1634, July-Sept 2011 Preconcentration and determination of trace amounts of Cd 2+ using multiwalled
More informationJournal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(1):67-71 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Synthesis and batch equilibrium adsorption chromatographic
More informationDepartment of Chemistry of Faculty of Science and Art, Sakarya University, Sakarya, Turkey
CEJC 3(2) 2005 252 262 Determination of gold, palladium and copper by flame atomic absorption spectrometry after preconcentration on silica gel modified with 3-(2-aminoethylamino)propyl group Mustafa Imamoglu,
More informationWhat type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation
What type of samples are common? Sample preparation 1 2 Number of samples? Time spent on different operations during LC analyses 3 4 Sources of error Aims Sample has to be representative Sample has to
More informationGlossary of Common Laboratory Terms
Accuracy A measure of how close a measured value is to the true value. Assessed by means of percent recovery of spikes and standards. Aerobic Atmospheric or dissolved oxygen is available. Aliquot A measured
More informationFluorescent Chemosensor for Selective Detection of Ag + in an. Aqueous Medium
Electronic supplementary information For A Heptamethine cyanine -Based Colorimetric and Ratiometric Fluorescent Chemosensor for Selective Detection of Ag + in an Aqueous Medium Hong Zheng *, Min Yan, Xiao-Xing
More informationColumn Preconcentration and Determination of Cobalt(II) Using Silica Gel Loaded with 1-Nitroso-2-naphthol
1516 Bull. Korean Chem. Soc. 2009, Vol. 30, No. 7 Eun Mi Shin and Hee-Seon Choi Column Preconcentration and Determination of Cobalt(II) Using Silica Gel Loaded with 1-Nitroso-2-naphthol Eun Mi Shin and
More informationDesign, synthesis, and application of chelating polymers for separation and determination of trace and toxic metal ions. A green analytical method*
Pure Appl. Chem., Vol. 73, No. 1, pp. 181 186, 2001. 2001 IUPAC Design, synthesis, and application of chelating polymers for separation and determination of trace and toxic metal ions. A green analytical
More informationenable measurement. This method separates these isotopes effectively.
Analytical Procedure URANIUM IN WATER 1. SCOPE 1.1. This is a method for the separation and measurement of uranium in water. After completing this method, source preparation for measurement of uranium
More informationReactive fluorescent dye functionalized cotton fabric as a Magic Cloth for selective sensing and reversible separation of Cd 2+ in water
Electronic Supplementary Material (ESI) for Journal of Materials Chemistry C. This journal is The Royal Society of Chemistry 2015 Supplementary Information Reactive fluorescent dye functionalized cotton
More informationSupporting Informations for. 1,8-Naphthyridine-based molecular clips for off-on fluorescence sensing
Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2015 Supporting Informations for 1,8-aphthyridine-based molecular clips for off-on fluorescence
More informationKapil Dev, Rita Pathak, G.N. Rao *
Sorption behaviour of lanthanum(iii), neodymium(iii), terbium(iii), thorium(iv) and uranium(vi) on Amberlite XAD-4 resin functionalized with bicine ligands Kapil Dev, Rita Pathak, G.N. Rao * Department
More informationDetermination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction
Determination of Trace Metals in Waters by FAAS Bull. Korean Chem. Soc. 2002, Vol. 23, No. 5 693 Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase
More informationElemental analysis of river sediment using the Agilent 4200 MP-AES
Elemental analysis of river sediment using the Agilent 4200 MP-AES Application note Environmental: Soils, sludges & sediments Authors Neli Drvodelic Agilent Technologies, Melbourne, Australia Introduction
More informationIn a typical routine, the pristine CNT (purchased from Bill Nanotechnology, Inc.) were
Supplementary Information Pd induced Pt(Ⅳ) reduction to form Pd@Pt/CNT core-shell catalyst for a more complete oxygen reduction Preparation of SH- functionalized CNT In a typical routine, the pristine
More informationSpeciation of Cr (III) and Cr (VI) in Water Sample by Spectrophotometry with Cloud Point Extraction
Speciation of Cr (III) and Cr (VI) in Water Sample by Spectrophotometry with Cloud Point Extraction M.Masrournia * 1, A.Nezhadali 2,B.Taghezadeh-Darban 3, Zahra Ahmadabaddi 1, Habib Mollaei 1 1 Department
More informationExperiment 14 - Qualitative Analysis
Introduction Qualitative analysis involves the identification of the substances in a mixture. When chemical methods are used in the identification of mixtures of metal cations, these ions are usually separated
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More information(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)
Analytical Procedure RADIUM IN WATER (CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This is a method for separation and measurement of radium-226 and radium-228 in water. This method
More informationLEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C
LEADX.01-1 LEAD (Colorimetric) PRINCIPLE SCOPE Organic matter in the sample is destroyed by ignition in the presence of sulfuric acid. The residue is dissolved in dilute acid, and the lead is complexed
More informationatomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive
Chapter 9: End-of-Chapter Solutions 1. The following comparison provides general trends, but both atomic absorption spectroscopy (AAS) and atomic absorption spectroscopy (AES) will have analyte-specific
More informationUsing FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples
A P P L I C A T I O N N ot e Atomic Absorption Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples Introduction The Flow Injection Mercury System (FIMS) is a dedicated system
More informationBATTERY INDUSTRY STANDARD ANALYTICAL METHOD
BATTERY INDUSTRY STANDARD ANALYTICAL METHOD For the Determination of Mercury, Cadmium and Lead in Alkaline Manganese Cells Using AAS, ICP-AES and "Cold Vapour" European Portable Battery Association (EPBA)
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.
Translated English of Chinese Standard: GB5009.17-2014 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF GB THE PEOPLE S REPUBLIC OF CHINA National Food Safety Standard-Determination
More informationMohammad Ali Taher*, Sayed Ziae Mohammadi Mobarakeh & Fatameh Saber Mahani
Indian Journal of Chemical Technology Vol. 12, January 2005, pp. 12-18 Application of 2-nitroso-1-naphthol-4-sulphonic acid for separation and preconcentration of trace cadmium and determination by differential
More informationReverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet
NU Science Journal 2006; 2(2): 165 173 Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water Jintana Klamtet Department of Chemistry, Faculty of Science, Naresuan University,
More informationExtraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2-Amino-Cyclopentene-1-Dithiocarboxylic Acid
J. Chemical Health Risks 2(1): 233, 212 Journal of Chemical Health Risks 2(1); 233 212 Extraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2AminoCyclopentene1Dithiocarboxylic
More informationWell-defined Surface Magnetic Ion-Imprinted Microspheres for Facile onsite Monitoring of Lead Ion at Trace Level in Water
Well-defined Surface Magnetic Ion-Imprinted Microspheres for Facile onsite Monitoring of Lead Ion at Trace Level in Water Yang Cui a, Jia-Qi Liu a, Zhang-Jun Hu a *, Xia-Wei Xu a, Hong-Wen Gao a State
More informationCu-Creatinine- Metol system
Quantification of Creatinine in Human Serum using Metol as a Chromogenic Probe Materials and methods 6.1. Reagents 6.1.1. N-methyl-p-aminophenol sulfate N-methyl-p-aminophenol sulfate also denoted as Metol
More informationAtomic Absorption Spectroscopy and Atomic Emission Spectroscopy
Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy A. Evaluation of Analytical Parameters in Atomic Absorption Spectroscopy Objective The single feature that contributes most to making atomic
More informationINVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY
C1_C0011 1 INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY Janya Buanuam,* Thareerut Woratanmanon, Temporn Sookawee Regional Failure Analysis and Reliability Laboratory,
More informationDRAFT EAST AFRICAN STANDARD
ICS 71.100.70 DRAFT EAST AFRICAN STANDARD Oils for cosmetic industry Methods of test Part 16 : Determination of Heavy metal Content EAST AFRICAN COMMUNITY EAS 2015 First Edition 2015 Copyright notice
More informationTECHNETIUM-99 IN SOIL
Analytical Procedure TECHNETIUM-99 IN SOIL 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in soil. 1.2. This method does not address all aspects of safety, quality
More informationNOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.
Determination of Cadmium and Lead in powdered infant formula by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction NOTICE: This method: - has to be considered only
More informationSupporting Information
Supporting Information Visual Determination of Cu 2+ through Copper-Catalysed in-situ Formation of Ag Nanoparticles Xun Yuan a and Yi Chen* a,b a Key Laboratory of Analytical Chemistry for Living Biosystems,
More informationPreparation and characterisation of a sorbent suitable for technetium separation from environmental matrices
Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices A. Bartosova, P. Rajec, M. Reich Faculty of Natural Sciences, Department of Nuclear chemistry,
More informationDETERMINATION OF TRACE OF HEAVY METALS IN WATER SAMPLES BY ATOMIC SPECTROMETRY BY PRECONCENTRATION WITH SOFT HUSK OF PISTACHIO
DETERMINATION OF TRACE OF HEAVY METALS IN WATER SAMPLES BY ATOMIC SPECTROMETRY BY PRECONCENTRATION WITH SOFT HUSK OF PISTACHIO Mehdi Ghodsbin [a], Hassan Zavvar Mousavi [a]* and Aisan Khaligh [a] Keywords:
More informationPerfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM
Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),
More informationMETHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)
METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE) 1.0 SCOPE AND APPLICATION 1.1 Method 7060 is an atomic absorption procedure approved for determining the concentration of arsenic in wastes,
More informationApplication note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer
Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer Application note Agriculture Authors Annie Guerin INRA, Laboratoire d Analyses
More informationHristina Nikolova, Miguel Angel Aguirre, Montserrat Hidalgo and Antonio Canals. 5-6 June 2012, Plovdiv, Bulgaria. 5-6 June 2012, Plovdiv, Bulgaria
Green analytical chemistry: Trace elemental analysis on water samples by liquid-liquid microextration (LLME)-laser- induced breakdown spectroscopy (LIBS) Hristina Nikolova, Miguel Angel Aguirre, Montserrat
More informationDepartment of Chemistry, Varamin Campus Islamic Azad University, Varamin, Iran
Asian Journal of Chemistry Vol. 20, No. 7 (2008), 5071-5081 Solid Phase Extraction of Ultra Trace Amounts of Cobalt and Nickel on Octadecyl Bonded Silica Membrane Disk Modified with N,N -Bis(3,5-di-tert-butylsalicylidene)-1,2-
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.
Translated English of Chinese Standard: www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA GB 5009.15-2014 National Food Safety Standard Determination
More informationEffective Adsorption of Pd(II), Pt(IV) and Au(III) by Zr- Cluster-Based Metal-Organic Frameworks from Strongly Acidic Solution
Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2017 Supporting Information Effective Adsorption of Pd(II), Pt(IV) and Au(III)
More informationJournal of Chemical and Pharmaceutical Research, 2015, 7(4): Research Article
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2015, 7(4):397-404 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Chromatographic separation of Pb(II), Cr(II), Cd(II),
More informationSample Prep Options for GC users
Sample Prep Options for GC users Tina Chambers Technical Specialist Sample Preparation tina.chambers@agilent.com 949-842-0493 Why Bother? Removal of interferences which would otherwise affect detection
More informationá233ñ ELEMENTAL IMPURITIES PROCEDURES
Second Supplement to USP 38 NF 33 Chemical Tests / á233ñ Elemental Impurities Procedures 1 á233ñ ELEMENTAL IMPURITIES PROCEDURES INTRODUCTION This chapter describes two analytical procedures (Procedures
More informationDeterminations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission
0 chapter Sodium and Potassium Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission Spectroscopy 67 S. S. Nielsen (ed.), Food Analysis Laboratory Manual Springer
More informationJournal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(1):27-32 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Some Theoretical Study on the Interaction Between
More informationAvailable online Research Article
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2015, 7(4):1069-1073 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Development of extractive spectrophotometric method
More informationChemical Analysis Problem
Chemical Analysis Problem Hair analysis is frequently used for the long-term monitoring of drug and alcohol users. You are working at a forensics laboratory and have been given the task of developing a
More informationhigh temp ( K) Chapter 20: Atomic Spectroscopy
high temp (2000-6000K) Chapter 20: Atomic Spectroscopy 20-1. An Overview Most compounds Atoms in gas phase high temp (2000-6000K) (AES) (AAS) (AFS) sample Mass-to-charge (ICP-MS) Atomic Absorption experiment
More informationDetermination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS
Determination of Total Bromine and Iodine Page 2 of 5 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes an inductively coupled plasma optical emission spectrometry method
More informationChapter 7 Adsorption thermodynamics and recovery of uranium
Chapter 7 Adsorption thermodynamics and recovery of uranium 99 Chapter 7. Adsorption thermodynamics and recovery of uranium from aqueous solutions by Spatoglossum 7.1. Materials 7.1.1. Preparation of sorbent
More informationISSN: (Online)
ISSN: 0976-2876 (Print) ISSN: 2250-0138(Online) DETERMINATION OF COPPER, NICKEL AND COBALT IN WATER AND FOOD SAMPLES BY FAAS AFTER SEPARATION AND PRECONCENTRATION USING MULTIWALLED CARBON NANOTUBES MODIFIED
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More informationSimultaneous determination of Zinc(II) and Cobalt(II) by First order derivative Spectrophotometry in Triton X-100 Micellar Media
Research Journal of Chemical Sciences ISSN 2231-66X Vol. 2(11), 8-13, November (212) Res.J.Chem. Sci. Simultaneous determination of Zinc(II) and Cobalt(II) by First order derivative Spectrophotometry in
More informationA "turn-on" coumarin-based fluorescent sensor with high selectivity for mercury ions in aqueous media
A "turn-on" coumarin-based fluorescent sensor with high selectivity for mercury ions in aqueous media Styliani Voutsadaki, George K. Tsikalas, Emmanuel Klontzas, George E. Froudakis, and Haralambos E.
More informationFast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES
Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Tran T. Nham Introduction
More informationJournal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2014, 6(5):1493-1499 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Detection of rubidium in mica using atomic absorption
More informationEnvironment Protection Engineering
Environment Protection Engineering Vol. 42 216 No. 4 DOI: 1.5277/epe1646 PARVIN EHSANI NAMIN 1 ADSORPTION OF COPPER, COBALT, AND MANGANESE IONS FROM AQUEOUS SOLUTIONS USING OXIDIZED MULTI-WALLED CARBON
More informationUltra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis. (Received 2 July 2016, Accepted 21 October 2016)
Regular Article ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH Published by the Iranian Chemical Society Anal. Bioanal. Chem. Res., Vol. 4, No. 1, 1120, June 2017. Ultratrace Determination of Palladium(II)
More informationUNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.
UNIVERSITI SAINS MALAYSIA Second Semester Examination Academic Session 2004/2005 March 2005 KAA 502 Atomic Spectroscopy Time: 3 hours Please make sure this paper consists of FIVE typed pages before answering
More informationDetermination of Cl-36 and I-129 by LSC after separation on an extraction chromatographic resin
Determination of Cl-36 and I-129 by LSC after separation on an extraction chromatographic resin Alexander Zulauf a, Bandombele Marcel Mokili b, Steffen Happel c, Phil Warwick d, Aude Bombard c, Hartmut
More information