Mechanisms of retention in HPLC

Size: px
Start display at page:

Download "Mechanisms of retention in HPLC"

Transcription

1 Mechanisms of retention in HPLC María Celia García-Álvarez-Coque Department of Analytical Chemistry University of Valencia Valencia, Spain 1 Part 2

2 Mechanisms of retention in HPLC Index 1. Retention in reversed-phase, normal-phase and HILIC 2. Secondary equilibria in reversed-phase liquid chromatography: Part A 3. Secondary equilibria in reversed-phase liquid chromatography: Part B 4. Retention modelling (quantification or prediction): Part A 5. Retention modelling (quantification or prediction): Part B 6. Gradient elution 7. Peak profile and peak purity 8. Computer simulation 2

3 2.1. Introduction 2.2. Ion-interaction chromatography Retention mechanism Common reagents and operational modes The silanol effect and its suppression Addition of perfluorinated carboxylate anions, chaotropic ions and ionic liquids Separation of inorganic anions with surfactant-coated stationary phases 2.3. Micellar liquid chromatography An additional secondary equilibrium in the mobile phase Hybrid micellar and high submicellar liquid chromatography 2.4. Recommended literature 3

4 2.1. Introduction In RPLC with hydro-organic mixtures as mobile phases, which is the prevalent chromatographic mode nowadays, the retention is theoretically explained by solute partitioning between the mobile phase and the bonded phase, which depends on the polarity: the more hydrophobic the solute, the longer its retention. To this, shape and steric constraints should be added. Partitioning Shape constraints Steric constraints 4

5 Limitations of RPLC Polar compounds (polar neutral or ionised organic compounds, and inorganic anions or metal ions) show little or no retention. log k c 0 c1 log P o/w HA Retention factor A Ionisable compounds Retention factor BH + B ph ph 5 This has been a challenge in environmental, clinical and food chemistry throughout the development of RPLC.

6 Limitations of RPLC There is no ideal support for preparing RPLC stationary phases. The vast majority is still prepared with silica, due to its attractive properties: easy derivatisation control of particle size and porosity mechanical stability BH + BH + BH + incompressibility However, owing to steric problems in the derivatisation of silica, silanol groups remain on the support in a non-negligible amount and, when ionised, they interact with cationic solutes by ionexchange processes that increase significantly the retention. Protonated silanols can also interact with some solutes through hydrogen bonding. The kinetics of the adsorption-desorption on silanols is slow, which yields tailed and broad peaks. 6

7 Addition of ionic reagents A solution to avoid the poor interaction with polar compounds and the silanol activity is the addition of reagents (additives) to the mobile phase, which give rise to diverse secondary reactions on the support, or within the mobile phase. A + H + HA Types of interactions: A A + A Ion-exchange processes with ionic lipophilic reagents adsorbed on the stationary phase, which attract solutes with an opposite charge or suppress the silanol activity. Formation of solute/additive ion pairs in the mobile phase. Acid-base reactions of ionisable compounds with changes of ph. Metal complexation C + + X C + X A + X AX (2.1) A : analysed solute (analyte) or silanol group on the support A M + L ML 7 X : a lipophilic ion, the hydrogen ion, a ligand, or other added species

8 The observed retention factor is a weighted average of the retention of the solute species. k k A ka kax K [X] A kax AX (2.2) 1 K [X] A : molar fraction of A AX : molar fraction of AX L H R Cu 2+ H [X] : molar concentration of X in the mobile phase K : formation constant (acid-base reaction: log K = pk a ) Two or more secondary equilibria may exist inside the column (even secondary equilibria of secondary equilibria). The aim is to enhance the chromatographic performance: change the absolute and relative retention to convenient values and improve the peak profile. 8 The addition of different types of reagents has given rise to new chromatographic modes and an impressive increase in the number of compounds that can be analysed by RPLC.

9 2.1. Introduction 2.2. Ion-interaction chromatography Retention mechanism Common reagents and operational modes The silanol effect and its suppression Addition of perfluorinated carboxylate anions, chaotropic ions and ionic liquids Separation of inorganic anions with surfactant-coated stationary phases 2.3. Micellar liquid chromatography An additional secondary equilibrium in the mobile phase Hybrid micellar and high submicellar liquid chromatography 2.4. Recommended literature 9

10 2.2. Ion-interaction chromatography Retention mechanism R 3 NH + Cl R 3 NH + R 3 NH + R 3 NH + A An RPLC mode with a broad scope of applications is achieved by adding amphiphilic cations or anions to the hydro-organic mixture (with both lipophilic and hydrophilic properties). The reagent typically contains a large organic ion that has a lipophilic region that interacts with the bonded chains on the stationary phase, and a charged region that interacts with an ionic solute. The stationary phase is modified and interacts with ionic species, but also with neutral species through polar interactions. C + BH + R S3 R S3 R S 3 Na + ACN The retention is regulated by the nature and concentration of the adsorbed lipophilic ion and organic solvent in the mobile phase, and by competing ions with the same charge as the analyte. HA R S3 10

11 Approaches The retention mechanism that takes place by addition of amphiphilic ions is not currently fully understood. Due to the complexity of the mobile phases, which contain the ionisable or ionic solute(s), and at least, the additive and buffer ions (and their counterions), it is not easy to explain their influence on the retention behaviour of ionic solutes. Adsorption of an ion pair In the origin of RPLC, bonded phases were considered as equivalent to a mechanically held liquid phase, and therefore, a liquid-liquid extraction mechanism was postulated. The proposed mechanism assumed the formation of an ion pair in the mobile phase by combination of the solute and the lipophilic ion of opposite charge, which partitions into the non-polar liquid layer on the stationary phase. A 11 Hence, the name ion-pair chromatography (IPC) taken from liquid-liquid extraction.

12 Dynamic ion-exchange mechanism Experimental facts further suggested that the lipophilic ion is distributed between the mobile phase and stationary phase, where it is adsorbed (immobilised), behaving as an ion exchanger for oppositely charged solutes. This model implies, essentially, an electrostatic interaction, stoichiometric approach followed for decades. and pioneered the A A 12

13 Non-stoichiometric approaches Broader perspectives describe the ionic solute as being under the summed influence of all ions in the chromatographic system. Solute retention is influenced by its transfer through the electrical double layer formed by the lipophilic ion (primary charged ion region) and counterion (diffuse outer region). A - A - A - This creates a surface potential, which depends primarily on three parameters: surface concentration of lipophilic ion mobile phase dielectric constant ionic strength The higher the surface concentration of lipophilic ion, the larger will be the effective ionexchange capacity, and hence, the retention of solutes with a charge opposite to the lipophilic ion. 13

14 The lipophilic ion is spaced over the stationary phase due to repulsion effects, which leaves much of the original stationary phase surface unaltered and available to interact with ionic and non-ionic solutes (dual mechanism). Small hydrophilic organic and inorganic anionic solutes probably interact primarily by electrostatic forces. The actual mechanism is rather complex. Solutes need to be ionised to interact with the ionic reagent. Therefore, the retention of ionisable compounds depends on the ph and pk a. B + Dual mechanism pk a R B + R HA HA Retention factor A 14 ph

15 Names Ion-pair chromatography is by far the most widely used term for this RPLC mode but it is not descriptive of the retention mechanism the term is usually associated with the addition of a small amount of the lipophilic ion to avoid an excess in the mobile phase, but in some cases, large amounts of reagent are added Paired-ion chromatography Ion-interaction chromatography (IIC) perhaps, the most correct term!!! Ion-modified chromatography Hetaeric chromatography (hetaeron means counterion) Surfactant (or soap) chromatography (with ionic surfactants) Submicellar liquid chromatography (surfactants below the CMC)

16 Common reagents and operational modes Reagents A A Any salt containing a lipophilic ion can be used as IIC reagent. Most applications imply salts of alkylammonium for anions, and alkylsulphonates or alkyl sulphates for cations. + The adsorbed ions may have different alkyl chain lengths: the longer the chain, the more hydrophobic the reagent, and the stronger its interaction with the bonded chains. The accompanying anion in alkylammonium salts can be: inorganic (chloride, hydroxide or phosphate) organic (salicylate or tartrate) The cation for alkylsulphonate and alkyl sulphate salts is usually: sodium or potassium Newer reagents are chaetropic salts and ionic liquids. alkylsulphonate 16 alkyl sulphate

17 perational modes Dynamic coating Permanent coating The lipophilic ion is added to the mobile phase. The major advantage is the possibility of controlling the column ion-exchange capacity by varying the mobile phase composition. A The stationary phase is equilibrated before the analysis with a highly lipophilic ion. The coating is strongly bound and persists for long periods of subsequent use. BH + R 3 NH + R 3 NH + R 3 NH + R S 3 R S 3 R S 3 17 To separate anions, the stationary phase must contain immobilised cations, and to separate cations, it must contain immobilised anions. The same column can be converted into an anion exchanger or a cation exchanger.

18 At increasing concentration of IIC reagent, retention increases up to saturation of the stationary phase surface. Meanwhile, at increasing organic solvent concentration, retention decreases, due to desorption of the reagent and competing equilibria in the mobile phase Benzyltrimethylammonium cyanopropyl-silica log k PrH R S 3 BH R S 3 R S 3 R S SDS, mm Propanol, % (v/v) Therefore, both IIC reagent and organic solvent should be kept constant in the mobile phase at specified concentrations, in order to maintain a reproducible ion-exchange capacity. 18

19 Something more to know A longer equilibration time is required with respect to conventional RPLC, to get a constant coating (to take especially into account in gradient elution). Relatively less-lipophilic IIC reagents are preferred, since they give rise to shorter analysis times, and can be more easily removed from the stationary phase surface. This can be done by washing the column with a polar organic solvent, such as methanol. Some lipophilic ions tend to associate very strongly to the stationary phase, changing the initial column properties permanently. A - It is not essential that the IIC counterion serves as the ion-exchange competing ion. ther ions are often added to assist in the elution of strongly retained anions: phosphate oxalate citrate phthalate 19

20 Something more to know For some IIC reagents, there is a need to saturate the mobile phase with silica to avoid stationary phase solubilisation. This is carried out by inserting a precolumn. System peaks chromatograms. corresponding to the added reagent will appear in the Traditional lipophilic reagents are not usually compatible with evaporative light scattering (ELS) and mass spectrometry (MS) detection. A - Injection 20 ELS MS

21 The silanol effect and its suppression The RPLC separation of nitrogen-containing basic compounds with silica-based columns present several problems, including long retention, peak tailing, poor efficiency, and strong dependence of retention on sample size. silanols BH + BH + BH + Atenolol Pindolol Acebutolol Timolol Metoprolol Celiprolol Esmolol Spherisorb C18 xprenolol Propranolol Alprenolol The effects are due to ion exchange of the protonated cationic solute on active (dissociated, anionic) silanols on the support Time, min 21 In order to reduce the silanol effect (silanol problem), much effort has been invested in the chemistry of bonded phases to eliminate metal impurities and residual silanols.

22 1. Retention in reversed-phase, normal-phase and HILIC Silanol activity: Underivatised silanols can interact with neutral solutes by hydrogen bonding, and with positively charged basic compounds by electrostatic attraction. This increases their retention and deteriorates the peak profile. Increasing acidity 22 Depends on: amount of available silanol groups relative acidic character type (isolated, geminal or vicinal) presence of metal impurities

23 The extreme differences in the behaviour toward basic compounds of packing materials labelled as being of the same type, such as bonded octadecyl-silica, is due to differences in the carrier silica, type of bonded silane, and coating level, which give rise to different amounts and different availability of surface silanols. Atenolol Pindolol Timolol Metoprolol Acebutolol Esmolol Celiprolol xprenolol Zorbax C18 Alprenolol Propranolol Atenolol Pindolol Acebutolol Timolol Metoprolol ACN / water Celiprolol Esmolol xprenolol Spherisorb C18 Propranolol 0 Atenolol Pindolol Timolol Acebutolol Metoprolol Esmolol Celiprolol xprenolol Nucleosil C18 Alprenolol+ + Propranolol Time, min Time, min Alprenolol Time, min 23 The brand-to-brand variation in selectivity of bonded-phase materials is, however, attractive. RPLC would never have reached so broad applicability if only hydrocarbon-like stationary phases were available: the separation chemistry becomes richer!!!

24 With the newer generation of RPLC columns, based on ultra-pure silica and improved bonding technologies, surface silanols have been significantly reduced, but the problem has not been completely eliminated: some tailing still remains. Solutions (and drawbacks) Reducing the ph below 3 to protonate residual silanols An extreme ph can damage the silica packing Increasing the ph to obtain neutral solutes Simultaneously more silanols are dissociated Masking the electrostatic interaction with IIC reagents (silanol blockers, silanol suppressors or anti-tailing reagents) An additional background for ELS and MS detection Column properties may result permanently altered 24

25 Several alternatives with IIC reagents Acidic mobile phases containing hydrophobic anions, such as alkylsulphonates or alkyl sulphates, are used to cover the stationary phase and improve the peak profile. Peak tailing suppression is not always successful, and the retention of basic compounds can increase excessively. The use of amines is also widespread. Better silanol suppression is achieved with bulky substituents. Quaternary amines or amines with long alkyl chains seem to be the best. Concomitantly with the improvement in peak profile, the retention of basic compounds may decrease excessively. A third option is the use of a combination of two ions of opposite charge, such as an alkylsulphonate and an amine. While the alkylsulphonate acts as IIC reagent (increasing the retention), the organic amine masks the residual silanols (which decreases the retention). This yields an efficient separation within a reasonable analysis time. BH + BH + BH + R3 NH+ R3NH + 25

26 Addition of perfluorinated carboxylate anions, chaotropic salts and ionic liquids Ionisation of carboxylic groups in amino acids and peptides can be suppressed at low ph. However, this together with the suppression of the silanol charge may cause early elution of these compounds and poor resolution, unless anionic reagents are added. Anionic reagents Alkylsulphonates H pk a1 2 A + HA +/- pk a2 A ph may strongly associate to the stationary phase making column regeneration difficult (TFA) Perfluorinated carboxylates are volatile, and thus, compatible with ELS and MS detection and also suitable for preparative chromatography. Trifluoroacetic acid (TFA) is the most common reagent due to its high purity, water solubility and transparency at 220 nm. 26

27 Hofmeister series ther anions (most inorganic) used for separation of zwitterions and basic compounds anions with a less localised charge, higher polarizability and smaller hydration degree associate stronger to the bonded phase and yield longer retention and enhanced peak profile, with the following trend: Chaotropicity PF 6 > Cl 4 > BF 4 > CF 3 C > N 3 > Cl > CH 3 S 3 > HC > H 2 P 4 chaotropic Hydration degree kosmotropic Chaotropicity or chaotropic effect is the ability to increase the disorder of water. This explains the adsorption of chaotropic anions and the retention behaviour of cationic solutes in their presence. The chaotropic effect also explains the retention behaviour in the presence of different buffers. 27

28 Mechanism of retention with hydrophilic anions The adsorption capability of the most hydrophilic anions in the Hofmeister series is small. Therefore, the retention mechanism with these anions has been explained by considering that: Cationic basic solutes are usually well solvated by the aqueous mobile phase, with little affinity for the lipophilic phase. However, cationic basic solutes can interact in the mobile phase with hydrophilic anions to form an ion pair, which produces disruption of the solvation shell. Since the ion pair is more lipophilic than the unpaired solute, it can be strongly retained by the stationary phase. A BH + Ion-pair chromatography!!! 28

29 Mono and dual character of reagents nly the anion or only the cation is adsorbed on the stationary phase: sodium hexanesulphonate and tetrabutylammonium hydroxide Both cation and anion are adsorbed (dual character): hexylamine salicylate, butylammonium phosphate, and ionic liquids the adsorption of cation or anion may be dominant!!! A A A A A A A A A A A A 29

30 Ionic liquids Known mainly as green solvents, but in RPLC they behave just like dissociated salts. Although little research still has been done on the effect of ionic liquids on retention, imidazolium tetrafluoroborates (BF 4 ) seem competitive against other common IIC additives, with regard to retention and the silanol-masking effect of the cation. Retention is excessive with a strong chaotropic anion, such as pentafluorophosphate. PF 6 > Cl 4 > BF 4 > CF 3 C > BF 4 - BF 4 - N CH 3 + N BF - 4 butyl charged bilayer BF 4 - BH + BF 4 - BF 4-1-butyl-3-methylimidazolium tetrafluoroborate 30

31 Ionic liquids Ionic liquid 1-R-3-Methylimidazolium cation N + N Anion m.p.. ( o C) d (g ml 1 ) Water solubility Physical state at room temperature R CH 3 EMIM PF 6 1-Ethyl- PF 6 BMIM BF 4 1-Butyl- BF 4 BMIM PF 6 1-Butyl- PF 6 HMIM BF 4 1-Hexyl- BF partially soluble solid soluble liquid non-soluble liquid immiscible liquid 31

32 Peak profiles Atenolol Pindolol Timolol Acebutolol Metoprolol Esmolol Atenolol Pindolol Timolol Metoprolol Acebutolol Esmolol xprenolol Celiprolol Celiprolol xprenolol Alprenolol Propranolol Alprenolol + Propranolol Retention time, min Retention time, min Nucleosil 18.1% acetonitrile Nucleosil 10.0% acetonitrile / M HMIM BF 4 32

33 Separation of inorganic anions with surfactant-coated stationary phases Surfactant coating is an easy and inexpensive way of converting silicabased RPLC packings into ion exchangers, offering different ionexchange capacities and selectivities. However, retention times may drift, due to coating leakage, with a need of periodic column regeneration. A reproducible behaviour needs a careful column equilibration to its plateau capacity. 33 Adsorbed CTAB, mmol m CTAB, M Silica methyl octadecyl cyanopropyl octyl bare

34 H 2. Secondary equilibria in reversed-phase liquid chromatography: Part A Cationic surfactants with quaternary ammonium groups are frequently used for the separation of inorganic anions. The stationary phase can be directly coated with the cationic surfactant. Coating first with a layer of nonionic surfactant, and then with the cationic surfactant, can yield improved chromatographic performance. H H H H H H H Brij-35 CTAB CTAB 34 cationic surfactant anionic + cationic surfactant

35 Need of competing ions A surfactant with a single functionality (anionic or cationic) requires a competing ion to release ionic solutes from the Stern layer to the bulk solution. Sodium dodecylsulphate (SDS) Cetyltrimethylammonium bromide (CTAB) 35

36 Need of competing ions With a zwitterionic surfactant (positive quaternary ammonium and negative sulphonate groups close to each other), ionic solutes experience simultaneous attraction and repulsion forces: there is no need of an ion-exchange competing ion. Coating with zwitterionic surfactant is termed electrostatic ion chromatography and is a kind of green chromatography, since the mobile phase can be just pure water or an electrolyte solution, such as NaHC 3 or Na 2 B 4 7. The addition of a cationic surfactant to the coating solution containing a zwitterionic surfactant increases the retention of divalent anions with respect to monovalent anions, and can change their elution order of both kinds of anions. 3-(N,N-dimethylmyristylammonio) propanesulphonate 36

37 2.1. Introduction 2.2. Ion-interaction chromatography Retention mechanism Common reagents and operational modes The silanol effect and its suppression Addition of perfluorinated carboxylate anions, chaotropic ions and ionic liquids Separation of inorganic anions with surfactant-coated stationary phases 2.3. Micellar liquid chromatography An additional secondary equilibrium in the mobile phase Hybrid micellar and high submicellar liquid chromatography 2.4. Recommended literature 37

38 2.3. Micellar liquid chromatography An additional secondary equilibrium in the mobile phase Above a certain concentration of an IIC reagent in the mobile phase, the stationary phase becomes saturated. Beyond this threshold, the retention, instead of further increasing, may progressively decrease. Secondary interactions Displacement of the adsorbed solute by the IIC counterion. Formation of ion pairs between the solute and IIC counterion. With surfactants, interaction with dynamic aggregates called micelles, formed above the critical micelle concentration (CMC). MLC Above the CMC, the amount of adsorbed surfactant on the stationary phase remains constant or is near saturation, which is an important feature with regard to robustness. 38 Micelles behave as a new phase (pseudophase) within the mobile phase, which leads into the field of another RPLC mode, named micellar liquid chromatography (MLC).

39 A A MLC BH k 60 k BMIM PF 6 (M) SDS (M)

40 Sodium dodecyl sulphate Cetyltrimethylammonium bromide 40

41 MLC is classified among the pseudophase liquid chromatographic modes. In the pseudophase LC modes (pseudo = false, imitation), the mobile phase contains entities that interact with solutes, such as: micelles cyclodextrins vesicles nanometer-sized oil droplets in oil-in-water microemulsions MLC has achieved the greatest impact due to its simplicity and low cost. The unique selectivity of MLC is attributed to the ability of micelles to organise solutes at the molecular level. However, the association of the surfactant monomers to the bonded phase creates a surface similar to the exterior of an open micelle, with deep implications with regard to retention and selectivity. 41

42 Types of surfactants Surfactants with ionic, zwitterionic and non-ionic head groups are used to separate ionic or neutral solutes that are able to interact with the surfactant. The anionic sodium dodecyl sulphate (SDS) is by far the most common surfactant in MLC, followed by the cationic cetyltrimethylammonium bromide (CTAB) and the non-ionic polyoxyethylene-(23)-dodecyl ether (Brij-35). Charged surfactants allow the separation of charged and neutral solutes, but anionic solutes eluted with an anionic surfactant and cationic solutes with a cationic surfactant will give peaks close to the dead time. 42

43 MLC Interactions BH + The surfactant chain is oriented to the mobile phase, changing the stationary phase polarity and type of interactions: BH + hydrophobic electrostatic for charged surfactants BH + specific interactions Brij-35 interacts strongly with hydroxyls BH + BH + BH + in phenols and polyphenols shape contraints steric constraints 43

44 Solutes are separated on the basis of their differential partitioning between the bulk aqueous phase and the micelles, or the surfactant-coated stationary phase. Both equilibria can be altered for ionisable compounds by tuning the ph. SDS CTAB 44

45 The mechanism of retention of solutes strongly associated to the surfactant through hydrophobic interaction (highly apolar solutes), electrostatic attraction, or specific interactions, should be explained by the direct transfer from the micelles to the surfactant-modified stationary phase. 45

46 Hybrid micellar and high submicellar liquid chromatography The idea of developing a chromatographic mode with aqueous micellar solutions as mobile phases (without organic solvent) is highly attractive. Green Chemistry: RPLC with water and soap QUE FIS BAI Flavonoids C18 / 0.04 M Brij o C FLA 0.6 CRY 3H 5H t R (min) 46

47 In most cases, pure micellar mobile phases (without organic solvent) have two problems: excessive retention and poor efficiency compared to conventional RPLC. With pure micellar mobile phases: the effective stationary phase thickness in the packing increases significantly, therefore, the strength of the interactions is larger and solute mass transfer within the stationary phase is difficult (slower) especially for highly hydrophobic solutes BH + BH + BH + 47

48 Basic drugs Time, min M SDS Time, min M SDS 15% (v/v) acetonitrile 48

49 The surfactant layer is decreased by addition of organic solvents to the mobile phase. rganic solvents dissolve the surfactant coating and form hybrid micellar mobile phases composed of surfactant and organic solvent. With a thinner surfactant layer on the stationary phase, the retention is decreased and the efficiency improved to practical values. Adsorbed SDS (mmol m 2 ) Propanol 1-Pentanol Methanol rganic solvent mole fraction Adsorbed CTAB (mmol m 2 ) 5.0 Methanol Propanol Pentanol rganic solvent mole fraction 49

50 Hybrid MLC The separation mode is still predominantly micellar in nature, but the micelle is perturbed by the organic solvent, giving rise to changes in the CMC and surfactant aggregation number (a mixed micelle can be obtained) SDS solutions 12.5 methanol 10.0 CMC (mm) ethanol 1-propanol acetonitrile butanol 1-pentanol tetrahydrofuran 0 50 % organic solvent (v/v) % organic solvent (v/v)

51 The presence of surfactants at high concentration increases the miscibility of organic solvents. This allows a wider range of organic solvents at concentrations larger than those in aqueous solution MLC expands the range of possible mixtures in RPLC. log P o/w methyl-1-butanol cyclohexanol hexanol 3-methyl-1-butanol 2-pentanol 1-pentanol 1-butanol 2-butanol 2-methyl-1-propanol 1-propanol acetonitrile ethanol methanol 2,3-butanediol 1,2-propanediol formamide Retention factor for benzene For historical reasons, alcohols (mainly propanol) are the most common organic solvents in hybrid MLC. Butanol and pentanol, which are stronger solvents, are used to elute strongly retained compounds. Acetonitrile (the most common solvent in conventional RPLC) has been scarcely used, but it gives rise to interesting separations!!!

52 About the efficiency In the first reports on MLC, the probe solutes were hydrophobic, which show poor performance in this chromatographic mode, especially in the absence of organic solvent. This may be the reason of the generalised idea that the peak profile in MLC is always poor, but in the presence of organic solvent, the peak profile can be similar or even improved with respect to conventional RPLC.

53 Mobile phases containing SDS give rise to ABH+ B A = B Time (min) highly symmetrical peaks for basic drugs. The suppression of the silanol effect is not due to a direct electrostatic interaction with the free silanols (case of amines), but to the protecting covering of the stationary phase, which prevents very efficiently that positively charged solutes penetrate into the bonded alkyl-chains to interact with the buried silanols. BH + BH + BH + Meanwhile, the ion-exchange mechanism with the sulphate group in the surfactant is a fast process. 53

54 SDS: effective silanol suppressor Time, min Kromasil column 15% (v/v) acetonitrile ph Time, min Kromasil column M SDS 15% (v/v) acetonitrile ph 3 54

55 In principle, a high percentage of organic solvent is not desirable, since it leads to micelle disruption. The organic solvent concentration (v/v) that still preserves the integrity of micelles is approximately: 15% for propanol and acetonitrile, 10% for butanol, and 6% for pentanol Higher concentrations of organic solvent can sweep out completely the adsorbed surfactant molecules from the bonded phase surface, or at least, avoid the formation of micelles (only surfactant monomers remain in the mobile phase). Without micelles (no more MLC!!!), as long as the stationary phase is covered by the surfactant layer, there will be a differentiated behaviour compared to hydro-organic RPLC. 55

56 Wrongly classified MLC procedures Compounds and sample Mobile phase composition Diverse drugs, biological fluids 0.04 M SDS / 55% methanol, ph M SDS / 70% acetonitrile, ph 3 Cortisol, urine 0.02 M SDS / 38% methanol / 2% 1-propanol, ph 6 Human growth hormone, fermentation broth Antioxidants, olive oil M SDS / 20 30% 1-propanol, ph M SDS / 30% 1-propanol, ph 2 Biogenic amines, food substrates 0.4 M SDS / 30-42% acetonitrile (gradient), ph 3 Azithromycin, formulations 0.1 M SDS / 15% 1-butanol, ph 7 Alkylbenzenesulphonates, ground and waste water 0.03 M SDS / 55 70% (gradient) methanol 56

57 A new chromatographic mode is achieved: high submicellar liquid chromatography (HSLC). HSLC Performance is even improved with respect to conventional RPLC or MLC: peak profiles and resolution can be better, and analysis times, shorter. CH 3 C N CH 3 C N CH 3 C N CH 3 C N CH 3 C N CH 3 C N This name indicates that the mobile phase contains a surfactant at a concentration where CH 3 C N CH 3 C N CH 3 C N CH 3 C N micelles are formed in water, but the high concentration of organic solvent does not allow their formation. CH 3 C N CH 3 C N CH 3 C N CH 3 C N CH 3 C N CH 3 C N 57

58 60 Acetonitrile, % (v/v) d low submicellar b c hydro-organic a high submicellar transition region micellar i h g f e β-blockers SDS, M (a) 1 (b) (c) IIC (d) 1 (e) 1 (f) MLC (g) 1 (h) 2 MLC 2 3 (i) 2 3 HSLC HSLC Time, min

59 Advantages of MLC The variety of interactions between solutes, stationary phase, aqueous phase, and micelles, which give rise to unique selectivity, often favourable to get good resolution. The possibility of separating both charged and neutral solutes in a single run. The separation of solutes in a wide polarity range with retention time windows narrower than in classical RPLC. This makes gradient elution less necessary. The low organic solvent concentration in hybrid MLC, which means lower toxicity and environmental impact of wastes with regard to conventional RPLC. The smaller evaporation of organic solvents, associated to the surfactant. This makes micellar mobile phases stable for a longer time and recirculation of mobile phase possible. Enhanced luminescence detection. 59

60 High submicellar liquid chromatography Tarragona, Secyta 2012 Injection of physiological fluids Major advantage: The high solubilisation capability of micelles, which facilitates dissolution of most matrices. This saves time in sample preparation, and allows the direct on-column injection of physiological fluids or other liquid samples containing proteins. 0.1 M SDS 1 2% butanol 0.1 M SDS 10 25% butanol The only real limitation of MLC is that direct on-line coupling to ELS and MS detection is hindered by the presence of the high concentrations of surfactant in the mobile phase. 60

Mechanisms of retention in HPLC

Mechanisms of retention in HPLC Mechanisms of retention in HPLC María Celia García-Álvarez-Coque Department of Analytical Chemistry University of Valencia Valencia, Spain https://sites.google.com/site/fuschrom/ 1 Part 3 Mechanisms of

More information

Mechanisms of retention in HPLC

Mechanisms of retention in HPLC HPLC 3 (Amsterdam) Mechanisms of retention in HPLC María Celia García-Álvarez-Coque José Ramón Torres-Lapasió Department of Analytical Chemistry University of Valencia Valencia, Spain https://sites.google.com/site/fuschrom/

More information

Liquid Chromatography

Liquid Chromatography Liquid Chromatography 1. Introduction and Column Packing Material 2. Retention Mechanisms in Liquid Chromatography 3. Method Development 4. Column Preparation 5. General Instrumental aspects 6. Detectors

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

The Theory of HPLC. Ion Pair Chromatography

The Theory of HPLC. Ion Pair Chromatography The Theory of HPLC Ion Pair Chromatography i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual.

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.

More information

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Colloidal dispersion

Colloidal dispersion Dispersed Systems Dispersed systems consist of particulate matter, known as the dispersed phase, distributed throughout a continuous or dispersion medium. The dispersed material may range in size from

More information

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS Islamic University in Madinah Department of Chemistry CHAPTER - ----- CHROMATOGRAPHIC METHODS OF SEPARATIONS Prepared By Dr. Khalid Ahmad Shadid Chemistry Department Islamic University in Madinah TRADITIONAL

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Module 4: "Surface Thermodynamics" Lecture 21: "" The Lecture Contains: Effect of surfactant on interfacial tension. Objectives_template

Module 4: Surface Thermodynamics Lecture 21:  The Lecture Contains: Effect of surfactant on interfacial tension. Objectives_template The Lecture Contains: Effect of surfactant on interfacial tension file:///e /courses/colloid_interface_science/lecture21/21_1.htm[6/16/2012 1:10:36 PM] Surface Thermodynamics: Roles of Surfactants and

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

HILIC Method Development in a Few Simple Steps

HILIC Method Development in a Few Simple Steps HILIC Method Development in a Few Simple Steps Monica Dolci, Luisa Pereira, Dafydd Milton and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Overview This poster presents a systematic approach

More information

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed Ion Exchange Chromatography (IEC) In this type of chromatography, the solid stationary phase )organic resin) is

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS CHAPTER 25: Opener Aa CHAPTER 25: Opener Ab CHAPTER 25: Opener B 25-1 Ion-Exchange

More information

Chromatography. Gas Chromatography

Chromatography. Gas Chromatography Chromatography Chromatography is essentially the separation of a mixture into its component parts for qualitative and quantitative analysis. The basis of separation is the partitioning of the analyte mixture

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Chromatographic Analysis

Chromatographic Analysis Chromatographic Analysis Distribution of Analytes between Phases An analyte is in equilibrium between the two phases [S 1 ] [S 2 ] (in phase 1) (in phase 2) AS [S2 ] K 2 A S [S1 ] 1 AS, A 1 S Activity

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

The Theory of HPLC. Normal Phase (Absorption) Chromatography

The Theory of HPLC. Normal Phase (Absorption) Chromatography The Theory of HPLC Normal Phase (Absorption) Chromatography i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this

More information

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. Chromatography Primer Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. At its heart, chromatography is a technique

More information

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).

More information

Hints for Strong Ion Exchange Resins

Hints for Strong Ion Exchange Resins Hints for Strong Ion Exchange Resins Chromatography Application Note AN98 Abstract Ion exchange columns are a powerful means of isolating and purifying compounds, but their use is limited due to lack of

More information

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania ESSENTIALS IN MODERN HPLC SEPARATIONS Serban C. Moldoveanu1, Victor David2 'R.J. Reynolds Tobacco Co., Winston-Salem, NC, USA 2University of Bucharest, Bucharest, Romania ELSEVIER AMSTERDAM BOSTON HEIDELBERG

More information

Protein separation and characterization

Protein separation and characterization Address:800 S Wineville Avenue, Ontario, CA 91761,USA Website:www.aladdin-e.com Email USA: tech@aladdin-e.com Email EU: eutech@aladdin-e.com Email Asia Pacific: cntech@aladdin-e.com Protein separation

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

Chapter 23 Introduction to Analytical Separations

Chapter 23 Introduction to Analytical Separations Chapter 23 Introduction to Analytical Separations Homework Due Monday April 24 Problems 23-1, 23-2, 23-7, 23-15, 23-27, 23-29, 23-32 Analytical Separations: Universal approach to analyzing complex mixtures

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

CHEM 429 / 529 Chemical Separation Techniques

CHEM 429 / 529 Chemical Separation Techniques CHEM 429 / 529 Chemical Separation Techniques Robert E. Synovec, Professor Department of Chemistry University of Washington Lecture 1 Course Introduction Goal Chromatography and Related Techniques Obtain

More information

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C Chromatography Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C Extremely varied and widely used methodology for separation

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

CHROMATOGRAPHY. The term chromatography is derived from the original use of this method for separating yellow and green plant pigments. CHROMATOGRAPHY The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments. THEORY OF CHROMATOGRAPHY: Separation of two sample components in

More information

Properties of Compounds

Properties of Compounds Chapter 6. Properties of Compounds Comparing properties of elements and compounds Compounds are formed when elements combine together in fixed proportions. The compound formed will often have properties

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

Introduction to Chromatography

Introduction to Chromatography Introduction to Chromatography Dr. Sana Mustafa Assistant Professor Department of Chemistry, Federal Urdu University of Arts, Science & Technology, Karachi. What is Chromatography? Derived from the Greek

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Full file at Chapter 2 Water: The Solvent for Biochemical Reactions

Full file at   Chapter 2 Water: The Solvent for Biochemical Reactions Chapter 2 Water: The Solvent for Biochemical Reactions SUMMARY Section 2.1 Summary Water is a polar molecule, with a partial negative charge on the oxygen and partial positive charges on the hydrogens.

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography Emqal module: M0925 - Quality parameters and optimization in is a separation technique used for quantification of mixtures of analytes Svein.mjos@kj.uib.no Exercises and lectures can be found at www.chrombox.org/emq

More information

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools Mark Langella WISTA The most modern and sophisticated methods of separating mixtures that the organic chemist has available

More information

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction Edouard S. P. Bouvier, Randy E. Meirowitz and Uwe D. Neue Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented

More information

Module 4: "Surface Thermodynamics" Lecture 22: "" The Lecture Contains: Examples on Effect of surfactant on interfacial tension. Objectives_template

Module 4: Surface Thermodynamics Lecture 22:  The Lecture Contains: Examples on Effect of surfactant on interfacial tension. Objectives_template The Lecture Contains: Examples on Effect of surfactant on interfacial tension file:///e /courses/colloid_interface_science/lecture22/22_1.htm[6/16/2012 1:10:07 PM] Example Consider liquid, its vapors and

More information

Open Column Chromatography, GC, TLC, and HPLC

Open Column Chromatography, GC, TLC, and HPLC Open Column Chromatography, GC, TLC, and HPLC Murphy, B. (2017). Introduction to Chromatography: Lecture 1. Lecture presented at PHAR 423 Lecture in UIC College of Pharmacy, Chicago. USES OF CHROMATOGRAPHY

More information

Chapter 2 Water: The Solvent for Biochemical Reactions

Chapter 2 Water: The Solvent for Biochemical Reactions Chapter 2 Water: The Solvent for Biochemical Reactions SUMMARY Section 2.1 Water is a polar molecule, with a partial negative charge on the oxygen and partial positive charges on the hydrogens. There are

More information

Extraction. A useful technique for purification of mixture. Dr. Zerong Wang at UHCL. Separation processes

Extraction. A useful technique for purification of mixture. Dr. Zerong Wang at UHCL. Separation processes Extraction A useful technique for purification of mixture Separation processes Liquid-liquid extraction Adsorption Filtration Solid-liquid extraction (leaching) Elution chromatography Membrane separation

More information

C18 Column. Care & Use Sheet

C18 Column. Care & Use Sheet C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin

More information

Chapter 02 The Chemical Basis of Life I: Atoms, Molecules, and Water

Chapter 02 The Chemical Basis of Life I: Atoms, Molecules, and Water Chapter 02 The Chemical Basis of Life I: Atoms, Molecules, and Water Multiple Choice Questions 1. The atomic number of an atom is A. the number of protons in the atom. B. the number of neutrons in the

More information

Colin F. Poole Department of Chemistry Wayne State University USA

Colin F. Poole Department of Chemistry Wayne State University USA Colin F. Poole Department of Chemistry Wayne State University USA Method Development Process Method Development Process Need to know what to do Before beginning experiments need to decide how to do it

More information

Biology 30 The Chemistry of Living Things

Biology 30 The Chemistry of Living Things Biology 30 The Chemistry of Living Things Hierarchy of organization: Chemistry: MATTER: Periodic Table: ELEMENT: Ex. oxygen, gold, copper, carbon COMPOUND: Ex. salt (NaCl), H 2 O ELEMENTS ESSENTIAL TO

More information

Chromatography. writing in color

Chromatography. writing in color Chromatography writing in color Outlines of Lecture Chromatographic analysis» Principles and theory.» Definition.» Mechanism.» Types of chromatography.» Uses of Chromatography. In 1906 Mikhail Tswett used

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

Chapter-2 (Page 22-37) Physical and Chemical Properties of Water

Chapter-2 (Page 22-37) Physical and Chemical Properties of Water Chapter-2 (Page 22-37) Physical and Chemical Properties of Water Introduction About 70% of the mass of the human body is water. Water is central to biochemistry for the following reasons: 1- Biological

More information

2. WATER : THE SOLVENT FOR BIOCHEMICAL REACTIONS

2. WATER : THE SOLVENT FOR BIOCHEMICAL REACTIONS 2. WATER : THE SOLVENT FOR BIOCHEMICAL REACTIONS 2.1 Water and Polarity Both geometry and properties of molecule determine polarity Electronegativity - The tendency of an atom to attract electrons to itself

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

1.17 Capillary electrophoresis

1.17 Capillary electrophoresis This text is based on the internationally-harmonized texts developed by the Pharmacopoeial Discussion Group (PDG). It has been developed and amended in line with the style and requirements of The International

More information

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A. Instrumental Analysis II Course Code: CH3109 Chromatographic &Thermal Methods of Analysis Part 1: General Introduction Prof. Tarek A. Fayed What is chemical analysis? Qualitative analysis (1) Chemical

More information

The change in free energy on transferring an ion from a medium of low dielectric constantε1 to one of high dielectric constant ε2:

The change in free energy on transferring an ion from a medium of low dielectric constantε1 to one of high dielectric constant ε2: The Born Energy of an Ion The free energy density of an electric field E arising from a charge is ½(ε 0 ε E 2 ) per unit volume Integrating the energy density of an ion over all of space = Born energy:

More information

Lecture 1 Solubility and Distribution Phenomena

Lecture 1 Solubility and Distribution Phenomena Physical Pharmacy Lecture 1 Solubility and Distribution Phenomena Assistant Lecturer in Pharmaceutics Overview Solubility Phenomena Introduction Solute-Solvent Interactions Solubility of gas in liquid

More information

16 years ago TODAY (9/11) at 8:46, the first tower was hit at 9:03, the second tower was hit. Lecture 2 (9/11/17)

16 years ago TODAY (9/11) at 8:46, the first tower was hit at 9:03, the second tower was hit. Lecture 2 (9/11/17) 16 years ago TODAY (9/11) at 8:46, the first tower was hit at 9:03, the second tower was hit By Anthony Quintano - https://www.flickr.com/photos/quintanomedia/15071865580, CC BY 2.0, https://commons.wikimedia.org/w/index.php?curid=38538291

More information

and water enriched layer at the stationary phase particle-eluent interface [9,11].

and water enriched layer at the stationary phase particle-eluent interface [9,11]. 8 A Simple, Generally Applicable HILIC Method Development Platform Based Upon Selectivity by Alan P McKeown, Advanced Chromatography Technologies Ltd, 1 Berry Street, Aberdeen, Scotland AB25 1HF, UK amckeown@ace-hplc.com

More information

Evolution of Mixed-Mode

Evolution of Mixed-Mode 24 August/September 2011 Evolution of Mixed-Mode Vlad.Orlovsky@sielc.com, Yury.Zelechonok@sielc.com SIELC Technologies Mixed-mode chromatography is emerging as a powerful tool in separation of various

More information

Water: The Solvent for Biochemical Reactions

Water: The Solvent for Biochemical Reactions Chapter 2 Water: The Solvent for Biochemical Reactions 11 SUMMARY Section 2.1 Section 2.2 Section 2.3 Section 2.4 Water is a polar molecule, with a partial negative charge on the oxygen and partial positive

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

1. Ion exchange chromatography

1. Ion exchange chromatography 1. Ion exchange chromatography Ion Exchange Chromatography Most popular method for the separation or purification of charged molecules. In cation exchange chromatography, positively charged molecules are

More information

Chromatographic Separation

Chromatographic Separation What is? is the ability to separate molecules using partitioning characteristics of molecule to remain in a stationary phase versus a mobile phase. Once a molecule is separated from the mixture, it can

More information

10/16/17 ACIDS AND BASES, DEFINED WATER IS AMPHOTERIC OUTLINE. 9.1 Properties of Acids and Bases. 9.2 ph. 9.3 Buffers

10/16/17 ACIDS AND BASES, DEFINED WATER IS AMPHOTERIC OUTLINE. 9.1 Properties of Acids and Bases. 9.2 ph. 9.3 Buffers ACIDS AND BASES, DEFINED A hydrogen atom contains a proton and an electron, thus a hydrogen ion (H + ) is a proton: Acids: Proton (H + ) transfer between molecules is the basis of acid/base chemistry Ø

More information

Water and solutions. Prof. Ramune Morkuniene, Biochemistry Dept., LUHS

Water and solutions. Prof. Ramune Morkuniene, Biochemistry Dept., LUHS Water and solutions Prof. Ramune Morkuniene, Biochemistry Dept., LUHS Characteristics of water molecule Hydrophylic, hydrophobic and amphipatic compounds Types of real solutions Electrolytes and non- electrolytes

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers. CHEM 322 Name Fall 2012 Due In Class Friday, Oct. 19 Complete the following on separate paper. Show your work and clearly identify your answers. General Separations 1. Describe the relative contributions

More information

Lab.2. Thin layer chromatography

Lab.2. Thin layer chromatography Key words: Separation techniques, compounds and their physicochemical properties (molecular volume/size, polarity, molecular interactions), mobile phase, stationary phase, liquid chromatography, thin layer

More information

LIQUID CHROMATOGRAPHY

LIQUID CHROMATOGRAPHY LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid

More information

H O H. Chapter 3: Outline-2. Chapter 3: Outline-1

H O H. Chapter 3: Outline-2. Chapter 3: Outline-1 Chapter 3: utline-1 Molecular Nature of Water Noncovalent Bonding Ionic interactions van der Waals Forces Thermal Properties of Water Solvent Properties of Water ydrogen Bonds ydrophilic, hydrophobic,

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

Chapter 9 Aqueous Solutions and Chemical Equilibria

Chapter 9 Aqueous Solutions and Chemical Equilibria Chapter 9 Aqueous Solutions and Chemical Equilibria At equilibrium, the rate of a forward process or reaction and that of the reverse process are equal. 9A The chemical composition of aqueous solutions

More information

Chromatographic Methods: Basics, Advanced HPLC Methods

Chromatographic Methods: Basics, Advanced HPLC Methods Chromatographic Methods: Basics, Advanced HPLC Methods Hendrik Küpper, Advanced Course on Bioinorganic Chemistry & Biophysics of Plants, summer semester 2018 Chromatography: Basics Chromatography a physical

More information

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

Chemistry 6/15/2015. Outline. Why study chemistry? Chemistry is the basis for studying much of biology.

Chemistry 6/15/2015. Outline. Why study chemistry? Chemistry is the basis for studying much of biology. Chemistry Biology 105 Lecture 2 Reading: Chapter 2 (pages 20-29) Outline Why study chemistry??? Elements Atoms Periodic Table Electrons Bonding Bonds Covalent bonds Polarity Ionic bonds Hydrogen bonding

More information

for Acclaim Trinity TM P1

for Acclaim Trinity TM P1 for Acclaim Trinity TM P Product Manual for Acclaim TRINITY P Columns Page of 4 Product Manual for Acclaim Trinity TM P Columns 07556 Acclaim Trinity P, 3µm, 4.6 x 00mm 07556 Acclaim Trinity P, 3µm, 4.6

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis Watch this lesson online: https://edrolo.com.au/vce/subjects/chemistry/vce-chemistry/aos-1-chemical-analysis/chromatography-hplc-glc/column-chromatography/#watch CHEMISTRY Unit 3, Area of Study 1: Chemical

More information

MAJOR FIELD TEST IN CHEMISTRY SAMPLE QUESTIONS

MAJOR FIELD TEST IN CHEMISTRY SAMPLE QUESTIONS MAJOR FIELD TEST IN CHEMISTRY SAMPLE QUESTIONS The following questions illustrate the range of the test in terms of the abilities measured, the disciplines covered, and the difficulty of the questions

More information

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation What type of samples are common? Sample preparation 1 2 Number of samples? Time spent on different operations during LC analyses 3 4 Sources of error Aims Sample has to be representative Sample has to

More information

SPE Columns. Solid Phase Extraction. SPE Columns

SPE Columns. Solid Phase Extraction. SPE Columns SPE Columns Solid Phase Extraction Solid-phase extraction (SPE) is a separation process by which compounds that are dissolved or suspended in a liquid mixture are separated from other compounds in the

More information

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction. LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT Thomas Wenzel, Bates College In-class Problem Set Extraction Problem #1 1. Devise a scheme to be able to isolate organic acids, bases

More information

High Pressure/Performance Liquid Chromatography (HPLC)

High Pressure/Performance Liquid Chromatography (HPLC) High Pressure/Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the

More information

HPLC Background Chem 250 F 2008 Page 1 of 24

HPLC Background Chem 250 F 2008 Page 1 of 24 HPLC Background Chem 250 F 2008 Page 1 of 24 Outline: General and descriptive aspects of chromatographic retention and separation: phenomenological k, efficiency, selectivity. Quantitative description

More information