SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer
|
|
- Lucas Arnold Bryant
- 6 years ago
- Views:
Transcription
1 SKALAR your partner in chemistry automation Primacs SN Protein-Nitrogen Analyzer
2 Applications Skalar has many years of experience developing applications for a variety of industries. Successful integration into production processes and professional after sales services are essential and part of our success. Skalar s Primacs SN analyzer is designed for Total Nitrogen (TN) and Protein analysis in a wide variety of sample types. The Primacs SN is based on the well-proven DUMAS high temperature combustion technology, which is in full accordance with international standard regulations such as AOAC, ASBC, AOCS, AACC and does not require extensive manual sample pretreatment. Optionally the Primacs SN analyzer can be extended to include the analysis of Total Carbon (TC) to then allow the determination of TC and TN simultaneously. Food & Animal feed Animal feed and other food products are analyzed for several reasons, such as monitoring product quality and compliancy with official regulations. Also the analysis of protein, through the measurement of Nitrogen, is used as a marker for the nutritional quality of food products. The Primacs SN is the perfect solution for accurate and rapid testing in laboratories, processing a wide variety of nutritional samples. Grain & Seed Nitrogen is a useful indicator of the protein content in grain and seed. The amount of protein determines the nutritive value and quality of the crop. Skalar s Primacs SN not only offers an accurate and reliable system for Nitrogen analysis, but also complete automation of sample testing is provided. Soil & Plant Soil testing is done to determine the level of nutrients in soil available for plants. The Nitrogen levels indicate soil composition during and after harvest. With Skalar s Primacs SN analyzer the determination of Total Nitrogen can be performed both rapidly and easily. Industrial waste In waste samples such as sludge, nitrogen analysis is important for pollution control. Ammonium, Nitrate, Nitrite and other Nitrogen compounds can serve as a nutrient source for troublesome water organisms. The Primacs SN offers a fast and consistent determination of Nitrogen levels in both solid and liquid industrial waste. Other applications Fishmeal Sediments Sludge and more
3 Primacs SN Total Nitrogen / Protein Analyzer Primacs SN Analyzer The Skalar Primacs SN analyzer is designed to measure Total Nitrogen / Protein in a variety of solid and/or liquid samples using the DUMAS combustion technology. DUMAS technique The Dumas combustion method has several advantages over the Kjeldahl technique in terms of speed and its environmental acceptability. In addition the Dumas method does not require any additional sample pretreatment such as digestion with toxic chemicals. The large sample size capacity of this instrument ensures reduced sample handling time and optimal automation. Detection is based on thermal conductivity. TCD detectors are able to process an extensive working range to cover nitrogen/protein levels from low parts per million to high percentage concentrations. The DUMAS combustion technology offers an accurate, rapid, safe, economical and environmentally friendly method for Nitrogen / Protein determination.
4 Combustion furnace Catalyst furnace Principle of operation Reduction furnace Peltier cooler Gas dilution Collection vessel Scrubbers TCD detection Autosampler The analysis on the Primacs SN Total Nitrogen / Protein analyzer is performed in a few steps: The sample is weighed in a quartz crucible and placed into the auto-sampler. The crucible is re-usable, which significantly lowers the cost-per-analysis. The sample weight is automatically transferred from the balance into the worklist in the software, avoiding any transcription errors. By a unique vertical bottom-to-top sample introduction system solid and/or liquid samples are combusted at high temperature. Nitrogen is converted into N x O y in presence of Oxygen. Due to the vertical sample introduction, the ashes remain in the crucible and are taken out of the instrument with removal of the crucible. This avoids sample ash build-up in the combustion zone and therefore reduces maintenance. After the catalyst furnace, where the oxidation reaction is activated, the sample passes the Peltier cooler to remove moisture formed by condensation. A fraction of the sample gas is transferred, by a sample splitter, to the reduction oven by the carrier gas Helium. With the presence of a copper reductor, the resulting Nitrogen oxides (N x O y ) are reduced to elemental Nitrogen while the by-products, water and Carbon Dioxide are completely removed. The remaining N 2 gas is measured by Thermal Conductivity Detection (TCD) and a background correction is performed by measuring the He gas. This will eliminate background interference.
5 Data Acquisition and Instrument Control The Primacs SN analyzer is controlled by the SN-Access software. It has been developed as an easy-to-learn and user-friendly program. Using pull-down menus for different actions it allows the operator to start analysis within a few minutes. During analysis the worklist can be modified, to enable the addition of priority samples, deleting samples or editing sample positions. The software always displays real-time information such as temperatures and detector signals, which is of major importance for reliable elemental analysis. SN-Access software features User defined alarm levels can be set for unattended safe operation User defined access levels to prevent unauthorized actions Raw data files are stored separately from data handling and data modification files Real-time graphs of analysis integration data for calibration and sample data For simultaneous Carbon and Nitrogen measurements both channels can be displayed in one screen as well as in separate screens Availability of peak editing mode, during or after analysis, for optimizing analysis data before reporting Export of analyzed data to other locations and to LIMS systems Storage of calibration curves and automatic best curve selection
6 Features and Benefits The Primacs SN is the perfect tool for Total Nitrogen analysis in a wide range of sample types. The system is optimized to fi t into routine daily operation for various industries. Features and Benefits Fully automated system with the latest technologies incorporated High sample throughput Sample weights up to 1 g of solid material can be applied Integrated random access carousel auto-sampler with unique vertical sample introduction system Analysis of liquid samples possible by a 3-step water removal Back fl ush system to remove ambient air for accurate low level analysis Low cost-per-sample analysis because of re-usable crucibles and low consumption of combustion and carrier gas Sample ash removal automatically from combustion zone after each sample analysis Minimum downtime for maintenance interventions Gas fl ow control by mass fl ow meters Results within minutes Simultaneous nitrogen and carbon analysis In compliance with ISO-13878, AOAC , AOAC , ASBC, AOCS Ba 11-65, AACC 46-30, and others Simultaneous Total Carbon & Nitrogen detection with the Primacs SNC Analyzer The Skalar Primacs SN can be extended for the analysis of Total Carbon by addition of an optional NDIR detector, which allows TC and TN determination at the same time. The analysis of Carbon and Nitrogen is important in for example soil characterization. The analysis takes place in one unit using high temperature catalytic combustion. Results of both analyses are obtained in parallel for each element with the SN-Access software.
7 Other Skalar TOC and TN Analyzers Solid Samples Primacs SNC TN / TC Analyzer This analyzer provides both Carbon and Nitrogen analysis in soil, plant, animal feed, food samples, sediments and sludge samples. The determination of Total Carbon and Total Nitrogen is combined in one system using high temperature catalytic combustion. Primacs ATC TC Analyzer This analyzer with integrated auto-sampler is designed for the analysis of Total Carbon and Total Organic Carbon in liquid and solid samples. Typical applications include soil, plant and fertilizer samples waste incinerators sludge and sediments cement industry mining industry. Primacs SLC TC / TIC / TOC Analyzer The Primacs SLC provides Carbon analysis on solid materials. Based on a dual furnace design, the system is capable of performing fast, reliable and separate determinations of TC and TIC without sample pretreatment. The TOC is automatically calculated (TOC = TC TIC). Primacs MCS TOC Analyzer The Primacs MCS TOC analyzer provides Total Organic Carbon analysis on solid materials. The analyzer is designed as an add-on module and operates in combination with the Formacs HT/LT TOC analyzer. It allows for the analysis of TC, IC and TOC. Liquid Samples Formacs HT TOC Analyzer The Formacs HT TOC analyzer provides a fast and reliable analysis of Total Organic Carbon (TOC) in liquid samples using high temperature catalytic combustion. The unit is designed to measure TC, IC, TOC, NPOC, POC and DOC in water samples. The instrument is customized for the sample type and optimized from a range of different catalysts. Optionally the Formacs HT can be extended for TN and NO 3 + NO 2 analysis. Formacs TN TN Analyzer A Total Nitrogen detector is available as an addition to the Formacs HT analyzer for TN analysis using a chemiluminescence detector in combination with high temperature oxidation. Optionally the Formacs TN can be extended for NO 3 + NO 2 analysis using Skalar s unique NN reactor. Formacs LT TOC Analyzer The Formacs LT TOC analyzer uses the UV-promoted persulfate digestion procedure to determine the Total Organic Carbon in liquid samples. After digestion of the Organic Carbon and oxidation to Carbon Dioxide (CO 2 ), the CO 2 is measured by Non Dispersive Infrared (NDIR) detection.
8 Contact Skalar USA Headquarters Skalar, Inc Bristol Industrial Way, Suite 107, Buford, GA Tel Toll Free: Fax info.usa@skalar.com United Kingdom Skalar (UK) Ltd. Breda House, Millfield Industrial Estate Wheldrake, York, YO19 6NA Tel (0) Fax (0) info.uk@skalar.com Belgium Skalar Belgium bvba Antwerpsestraat Boom Tel (0) Fax (0) info.belgium@skalar.com Skalar s Headquarters Skalar Analytical B.V. Tinstraat AA Breda The Netherlands Tel. +31 (0) Fax. +31 (0) info@skalar.com Internet: For more information please contact your local Skalar agent or Skalar s headquarters in the Netherlands Copyright Skalar 2010 Publication No C.US Germany Skalar Analytic GmbH Gewerbestraße Süd Erkelenz Germany Tel (0) Fax (0) info.germany@skalar.com Austria Skalar Analytic GmbH Am Anger 22 A-7451 Oberloisdorf Austria Tel (0) Fax (0) info.austria@skalar.com France Skalar Analytique S.A.R.L. 79, Avenue Aristide Briand Arcueil Tel (0) Fax (0) info.france@skalar.com Skalar reserves the right to change the specifications and the appearance of the equipment without further notification.
SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer
SKALAR your partner in chemistry automation Primacs SNC Total Carbon and Total Nitrogen Analyzer Applications Measuring Carbon and Nitrogen levels is important in soil, plant, animal feed, food samples,
More informationSKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers
SKALAR your partner in chemistry automation Formacs series Total Organic Carbon & Total Nitrogen Analyzers Skalar s Formacs HT TOC / TN Analyzer The Formacs HT TOC/TN analyzers provide fast, reliable analysis
More informationSKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer
SKALAR your partner in chemistry automation The San ++ continuous flow analyzer Applications Over the years Skalar has been working and developing applications for a variety of industries. Our comprehensive
More informationNitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases
APPLICATION NOTE 42255 Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases Authors Dr. Liliana Krotz, Dr. Francesco
More informationSKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer
SKALAR your partner in chemistry automation The San ++ continuous flow analyzer Applications Over the years Skalar has been working and developing applications for a variety of industries. Our comprehensive
More informationFusion UV/Persulfate TOC Analyzer
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer
More informationAPPRENTICESHIP AT SKALAR S LABORATORY. The organization Skalar Analytical BV. The product lines of Skalar Analytical BV
SKALAR Laboratory & Process Analysis APPRENTICESHIP AT SKALAR S LABORATORY The organization Skalar Analytical BV Skalar is a Dutch manufacturer of high quality automated analyzers for laboratories and
More informationFusion UV/Persulfate TOC Analyzer
Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate oxidation allowing superior carbon liberation from even the most challenging
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationThermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS
Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier
More informationECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer
ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is
More informationTotal Organic Carbon, Total Nitrogen
Thermalllox TOC--TN The modern alternative to COD and TKN Thermal oxidation with unrivalled sensitivity Aqueous matrices with a solids option TOC, TC, TIC, NPOC, POC, TN b Total Organic Carbon: Total Carbon:
More informationBECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple
BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple Reliable TOC measurements Stop throwing away your first rep. QbD1200 has virtually eliminated sample-to-sample carryover
More informationTRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:
TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle: > Heterogeneous samples like sludge, wood, soil, fertilizers, agricultural
More informationcostech instruments ECS 4010 Elemental Combustion System CHNS-O
instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:
More informationInnovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer
Innovative 0.01 0.1 1 10 Intuitive Concentration (ppb) R = 0.99999 Versatile Hydra II C Mercury Analyzer At Teledyne Leeman Labs; atomic spectroscopy is our business our only business. We are industry
More informationCharacterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer
Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 000 Elemental Analyzer Dr. Liliana Krotz and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy
More informationThe. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples
The Hydra II Family of Mercury Analyzers At Teledyne Leeman Labs, atomic spectroscopy is our business our only business. We are industry leading innovators with a proven track record providing systems
More informationMercury Stack Monitor SM-4
Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix
More informationTotal Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications
Application Note 35140710 Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications Keywords 1030S Solids Module Aurora 1030 TOC Analyzer High Temperature Catalytic
More informationThermo Scientific FLASH HT Plus Elemental Analyzer for IRMS
m a s s s p e c t r o m e t r y Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS Fully Automated Multi-Element Isotope Analysis for C, N, S, O, H Food Testing Forensics Environmental Analysis
More informationAccurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer
APPLICATION NOTE Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer AN42266 Dr. Liliana Krotz, Dr. Francesco Leone and Dr. Guido Giazzi Thermo Fisher Scientific,
More informationBasic Digestion Principles
Basic Digestion Principles 1 From Samples to Solutions Direct Analytical Method Solid Sample Problems: Mech. Sample Preparation (Grinding, Sieving, Weighing, Pressing, Polishing,...) Solid Sample Autosampler
More informationFinnigan TC/EA. High Temperature Conversion Elemental Analyzer
m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA
More informationThe art of elemental analysis
vario MACRO CUBE The art of elemental analysis 100 years ago, in the center of Germany, near Frankfurt, the advanced technology company Heraeus developed and manufactured the world s first elemental analyzer
More information3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement
3. Chemical industry The most commonly used compound in the chemical industry is water not only as a solvent in processing, but also as an energy carrier in the cooling or heating cycle. As vast amounts
More informationDMA-80L TECHNICAL SPECIFICATIONS
DMA-80L Advantages Determination of Mercury in water and digestates Unique atomic absorption spectrometer, optical paths with three independent signals Short analysis time, typically less than 2 minutes
More informationCarbon (Organic, and Inorganic)
DATE: January 2011 Carbon (Organic, and Inorganic) 1. Application This method covers the determination of total organic carbon (TOC), and inorganic carbon (IC) concentrations in soil, plant tissues and
More informationCEO LETTER. - Rolf Ludwig
CEO LETTER Digital Data Systems are the proud designers and manufacturers of CAL2K Isothermal Oxygen Bomb Calorimeter Systems, CAL3K Isothermal, Adiabatic and Dynamic Bomb Calorimeters The DDS CAL3K range
More information110 Lowell Rd Hudson, NH USA Tel:
110 Lowell Rd Hudson, NH 03051 USA Tel: 603-886-8400 www.teledyneleemanlabs.com Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental
More informationUDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS
LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl
More informationApplication Note No. 116 / 2013 Nitrogen determination in sodium nitrate
Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate KjelMaster K-375: Determination of nitrogen in sodium nitrate according the the Devarda method 1. Introduction An easy, quick and
More informationExploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis
Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,
More informationUniversity Wet Chemistry Analyzer Packages
University Wet Chemistry Analyzer Packages University laboratories and public research institutions have a special place in the scientific community. Often they are tasked with undertaking basic research
More informationTOUR OF SOIL CHEMISTRY LABS (09/22/07)
Department of Crop and Soil Sciences Commemorating Our Centennial, 1907 2007 TOUR OF SOIL CHEMISTRY LABS (09/22/07) WELCOME TO THE TOUR OF SOIL CHEMISTRY LABS Instrument: Lachat QuikChem FIA + 8000 Analyzer
More informationProduct Descriptions and Offerings
Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental analysis. Laboratories in industries ranging from environmental science, oil and
More informationApplication Note No. 310/2018
Application Note No. 310/2018 Nitrogen determination in compound fertilizer according to Devarda KjelFlex K-360 with Devarda Splash Protector, Metrohm Titrino 877 www.buchi.com Quality in your hands 1.
More informationAdvanced technics in the. (TIC/TOC/TNb)
Advanced technics in the determination of sum parameters (TI/T/Tb) Andreas Martens, Elementar Analysensysteme Gmb, anau, Germany БЕОГРАД, 02.09.2008 What is a sum parameter? Definition: sum parameter A
More informationFast and effective. quality monitoring for breweries. Thermo Scientific Gallery Plus Beermaster
Thermo Scientific Gallery Plus Beermaster Fast and effective quality monitoring for breweries Colorimetric beer, wort and malt analysis Automated bitterness analysis Thermo Scientific Gallery Plus Beermaster
More informationTotal Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS
Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS Tomoko Vincent 1, Simon Lofthouse 2, Daniel Kutscher 1 and Shona McSheehy Ducos
More informationAOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion
AOAC Official Method 2016.xx Determination of Total Sulfur in Fertilizers by High Temperature Combustion Proposed First Action 2015 (Applicable for measuring total sulfur concentration in solid and liquid
More informationAutomated Clinical Analyzer
Automated Clinical Analyzer Improved ease of operation and better test efficiency, and provides the optimal solution for routine operations, STAT operation and a broad range of clinical analysis requirements.
More informationAstoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:
ASTORIA-PACIFIC rapid-t with Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer: Durable. Accurate. Precise. Economical Open software
More informationMeasurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination
Measurement & Analytics Measurement made easy MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Adapted for polyols and polyurethanes applications The MB3600-CH70 Polyol Analyzer
More informationEnCal 3000 Hydrocarbon Dew Point Calculation - C 9 analysis - C 12 analysis
EnCal 3 Hydrocarbon Dew Point Calculation - C 9 analysis - C 12 analysis Introduction Process gas chromatographs are the standard tool for gas quality analysis. Classic devices provide an analysis of the
More informationDI 3500 Discrete Aoalvzer
DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged
More informationDYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.
DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS. www.hidenisochema.com The IGAsorp is a fully automated compact bench-top DVS
More informationESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS
ESPRIT Feature Particle detection and chemical classification Innovation with Integrity EDS Fast and Comprehensive Feature Analysis Based on the speed and accuracy of the QUANTAX EDS system with its powerful
More informationMM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE
MM 2 The new Generation of Mobile Mass Spectrometers Innovation with Integrity Defence CBRNE Picture by: MOWAG GmbH Mobile CWA Detection and Identification Low weight and high performance detector Introducing
More informationLCTech GmbH Chromatographie
EVA III - an analytical preparation system for all kinds of applications a new system by LCTech that makes work so much easier Overview of Contents: y Broad Spectrum of Application y Automatisation of
More informationASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t
ASTORIA PACIFIC Automated Wet-Chemistry Analyzers and Diagnostic Reagents rapid-t rapid-t System ASTORIA-PACIFIC PROUDLY OFFERS OUR rapid-t SYSTEM: Durable. Accurate. Precise. Economical. Open software
More informationAutomating Wet Chemical Analysis
Automating Wet Chemical Analysis Who Should Automate? Anyone looking to improve laboratory efficiency Environmental Agricultural Food and beverage Pharmaceutical Mining Etc. Advantages of Automating Save
More informationHydra-C Application Note: 1076
Hydra-C Application Note: 1076 The Determination of Mercury in Samples by U.S. EPA SOW 846 Method 7473 using the Hydra-C Mercury Analyzer Introduction The accurate determination of mercury in various samples
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationCadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
More informationCadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows
Nitrate DOC316.53.01067 Cadmium Reduction Method Method 8192 0.01 to 0.50 mg/l NO 3 N (LR) Powder Pillows Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
More informationINFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer
INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR 5000 Simply more DR 5000 UV-VIS Spectrophotometer DR 5000_UV-VIS SPECTROPHOTOMETER More than a Photometer The DR 5000 UV-VIS Spectrophotometer
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationElemental Analysis: CHNS/O characterization of polymers and plastics
APPLICATION NOTE 0 Elemental Analysis: CHNS/O characterization of polymers and plastics Authors Introduction Dr. Liliana Krotz and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy The chemical composition
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationAutomating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008
Automating Wet Chemical Analysis William Lipps Market Specialist for Water Analyzer Products December 11, 2008 The advantages of automating wet chemical analysis. Save time Decrease cost Improve quality
More informationPyrolysis process for the treatment of food waste. Barbora Grycová VSB - Technical University of Ostrava Czech Republic
Pyrolysis process for the treatment of food waste Barbora Grycová VSB - Technical University of Ostrava Czech Republic INTRODUCTION Wastes from the food production are still mostly disposed of by landfilling,
More informationThe Claviature of Gas Analysis
The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern
More informationNON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)
Gas Chromatography NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) The Non-Methane Organic Compounds (NMOC) Analyzer is a gas chromatograph configured for analyzing gaseous samples for total organic
More informationSpeed and flexibility
Speed and flexibility Automate your environmental, water, detergent, food and beverage analysis Thermo Scientific Gallery and Gallery Plus discrete industrial analyzers Improve productivity, reproducible
More informationElemental Analysis: NCS characterization of paper
APPLICATION NOTE 42231 Elemental Analysis: NCS characterization of paper Authors Dr. Liliana Krotz, Dr. Francesco Leone and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy Keywords Argon, CHNS/O,
More informationSIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent
More informationAnalysis of domestic sludge using the Agilent 4200 MP-AES
Analysis of domestic sludge using the Agilent 4200 MP-AES Application note Environmental Authors Neli Drvodelic Agilent Technologies, Melbourne, Australia Introduction Managing the treatment and disposal
More informationSIFT-MS. technology overview
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS
More informationPersulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials
Nitrogen, Total DOC316.53.01085 Persulfate Digestion Method Method 10072 2 to 150 mg/l N (HR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific information
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationPersulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials
Nitrogen, Total DOC316.53.01086 Persulfate Digestion Method Method 10071 0.5 to 25.0 mg/l N (LR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationAssessment Schedule 2016 Biology: Demonstrate understanding of biological ideas relating to micro-organisms (90927)
NCEA Level 1 Biology (90927) 2016 page 1 of 5 Assessment Schedule 2016 Biology: Demonstrate understanding of biological ideas relating to micro-organisms (90927) Evidence Statement Question One No response
More informationShorten your Time-to-Result
Shorten your Time-to-Result Effective quality and process control requires the shortest time-to-result possible. This is the time needed from sampling to the final quantitative result. Any advantage results
More informationCadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3
, MR, 8171 DOC316.53.01069 Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3 N) Powder Pillows or AccuVac Ampuls Scope and Application: For water, wastewater and seawater Test preparation
More informationlems. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement task.
TOC the Chemical Industry TOC Measurement Application in Handbook Chemical Industry 3. Chemical industry The most commonly used compound in the chemical industry is water not only as a solvent in processing,
More informationMeasurement Technique and its Application to Trace Components of Atmospheric Gas
F e a t u r e A r t i c l e Feature Article Measurement Technique and its Application to Trace Components of Atmospheric Gas Junji Kato From early on, HORIBA has been developing and adopting various measurement
More information3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement
3. Chemical industry The most commonly used compound in the chemical industry is water not only as a solvent in processing, but also as an energy carrier in the cooling or heating cycle. As vast amounts
More informationAMMS-100 Atmospheric Metal Monitoring System
AMMS-100 Atmospheric Metal Monitoring System USEPA Method IO-. compliant Measure 28 toxic metals simultaneously Magnitude of detection limit 0.01-0.1ng/m Associate measurements with time of day or meteorological
More informationNitrate Reductase (NR) Colorimetric Assay Kit
(FOR RESEARCH USE ONLY. DO NOT USE IT IN CLINICAL DIAGNOSIS!) Nitrate Reductase (NR) Colorimetric Assay Kit Catalog No: E-BC-K158 Method: Colorimetric method Specification: 100 Assays This manual must
More informationMethod to 0.50 mg/l NH 3 N Powder Pillows
, 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows
More informationExamining the Role of TOC Analyzers in the Pharmaceutical Laboratory
Shim adzu Scientific Instrum ents, 7102 Riverwood Drive, Columbia, MD 21046 Tel: 800.477.1227/410.381.1227; Fax: 410.381.1222; www.ssi.shimadzu.com Examining the Role of TOC Analyzers in the Pharmaceutical
More informationISO 8245 INTERNATIONAL STANDARD. Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
INTERNATIONAL STANDARD ISO 8245 Second edition 1999-03-01 Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC) Qualité de l'eau Lignes directrices
More informationDR/4000 PROCEDURE NITRATE. Using Powder Pillows
DR/4000 PROCEDURE Method 8171 Powder Pillows or AccuVac Ampuls Cadmium Reduction Method MR (0 to 5.0 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit
More informationLevel. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.
Automate your processes Automate your lab Innovate with EasyPREP sample handler Automated Sample Preparation Dispense up to 7 reagents Dilute Samples Aliquote Samples Transfer Samples Normalize Samples
More informationAutomated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES
TECHNICAL NOTE 43252 Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES Keywords Auto-dilution, Intelligent dilution,
More informationMethod to 0.50 mg/l NH 3 N Powder Pillows
, 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows
More informationOxygen Demand, Chemical
Oxygen Demand, Chemical DOC316.53.01103 USEPA Reactor Digestion Method Method 10211 1 to 60 mg/l COD (ULR) TNTplus 820 Scope and application: For wastewater, process water, surface water, and cooling water.
More informationFast, Effective XPS Point Analysis of Metal Components
Application Note: 52297 Fast, Effective XPS Point Analysis of Metal Components Chris Baily and Tim Nunney, Thermo Fisher Scientific, East Grinstead, West Sussex, UK Key Words K-Alpha Auto-Analysis Multi-Spectrum
More informationH E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System
H E L P I N G C H E M I S T S UltraCLAVE The Next Generation Microwave Digestion System UltraCLAVE The Next Generation Microwave Digestion System Improving upon an established technology is always a challenge.
More informationS2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF
S2 PICOFOX Spectrometry Solutions Innovation with Integrity TXRF S2 PICOFOX True Trace Analysis with XRF for the First Time! You need to know the concentration of trace elements in environmental samples?
More informationHigh Pressure DSC Differential Scanning Calorimeter
High Pressure DSC Differential Scanning Calorimeter Introduction The Differential Scanning Calorimetry (DSC) is the most popular thermal analysis technique to measure endothermic and exothermic transitions
More informationThe Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.
The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL. Weather Data Benefit For Society The four most important things about weather prediction are quality, reliability,
More informationTotal elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS
APPLICATION NOTE 43326 Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS Authors Introduction Tomoko Vincent1, Simon Lofthouse2,
More informationElemental Scientific. Spike Recovery. Elemental Scientific
Elemental Scientific prepfast ICP-MS: USP Oral Drugs by Dissolution Automated Inline Calibration and Sample Dilution Authors: Kyle Uhlmeyer and Paul Field (field@icpms.com) Brief The prepfast
More informationFocus Series Peptide Synthesizers
Focus Series Peptide Synthesizers aapptec is well known for its innovation and leadership in automated peptide synthesizers. aapptec technology has been an industry leader for the past 30 years around
More informationIncreasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer
Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance
More informationReprint. Project Summary. Side by Side Evaluation of ChemScan UV-4100 and Hach (Dr. Lange) Optiquant at Littleton-Englewood Colorado
ChemScan Process Analyzer Reprint Project Summary Side by Side Evaluation of ChemScan UV-4100 and Hach (Dr. Lange) Optiquant at Littleton-Englewood Colorado Published by: Applied Spectrometry Associates,
More informationIdeal and powerful solution
Thermo Scientific Indiko Plus Clinical and specialty chemistry system Ideal and powerful solution for operational excellence Enzymes Substrates Electrolytes Specific Proteins Drugs of Abuse Analysis Therapeutic
More information