MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Size: px
Start display at page:

Download "MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE"

Transcription

1 MM 2 The new Generation of Mobile Mass Spectrometers Innovation with Integrity Defence CBRNE

2 Picture by: MOWAG GmbH Mobile CWA Detection and Identification Low weight and high performance detector Introducing a novel vacuum system reflects the trend towards modern high-performance, lightweight detection equipment and the application of current micro-controller based technologies for instrument control. With a volume of 43 litres and a weight of 35 kg, a milestone in GC/MS technology has been reached. Integration of the MM2 into the Piranha vehicle Ready to face terrorist attacks In a world of changing threats, the MM2 represents the latest development in military-hardened, mobile and lightweight GC/MS systems. Its design is benefiting from more than 25 years of experience in mobile mass spectrometry at Bruker Daltonics. The MM2 is the state-of-the-art mass spectrometer for the detection and identification of chemical agents and toxic industrial chemicals in defence and homeland security applications. The MM2 is optimized for long-term chemical reconnaissance in various armoured vehicles, as well as for mobile chemical agent inspection and detection missions that require positive identification. Mobile mass spectrometry is also the technology of choice for the identification of unknown chemical compounds due to its specificity, especially in combination with gas chromatography. New generation of GC/MS The MM2 represents a new generation of quadrupole mass spectrometers with a membrane inlet. Equipped with various accessories, such as the air/surface probe and the gas chromatograph with thermodesorption, all current chemical detection tasks can be easily tackled. Easy operation and flexible applications The MM2 is able to identify any organic chemical from any medium (soil, water or air) within 15 minutes via complementary sampling techniques. Specifications and performance are not limited to a selected portion of chemicals. New libraries can be created and used by the customer. The detection limit for volatile organic compounds and volatile agents is from the low ppb to the low ppm range depending on the analytical procedure, e.g. adsorbent enrichment (low ppb range) or on-line monitoring (very low ppm range) from ambient air. Vehicle integration The system can be integrated into vehicles or networks consisting of chemical and biological detectors. Training and operation has been optimized and simplified whilst the reliability has been improved. Representing a new level of highly professional, on-site analysis technology the MM2 has been selected to become part of all kind of mobile and stationary chemical detection missions all over the world.

3 MM2 the New Generation MM2 GC MM2 - Small, flexible and to count on MM2 Surface Sampler Military Air / Surface Probe MM2 mounting for shock and vibration prevention Surface Sampler Remote Control MM2 basic unit with flexible air surface probe for sampling with extended probe via heated probe head MM2 gas chromatograph (GC) Inlet: Desorber/Injector programmable up to 240 C Carrier gas: ambient air Capillary: HT5 / 15 m GC temperature range: 3 ramps up to 240 C

4 Accessories for Various Applications with the MM2 MM2 surface sampler (left picture) Enrichment of Tenax -Tubes with persistent chemicals Programmable sampling time Operated directly or via remote control unit MM2 air/surface probe (right picture; military version) Separately heated probe head and line Probe line length: 3.5 m Preset temperatures range: up to 240 C MM2 air sampler Enrichment of Tenax -Tubes with volatile chemicals Programmable sampling time Tenax sampling tubes with cartridges Sampling wheel for taking samples from soil (FOX Reconnaissance vehicle) Picture: Rheinmetall AG

5 MM2 Analysis - Monitoring Controlling and Data Acquisition The MM2 is enhanced by two software modules for instrument control and data acquisition. The MM2 Analysis (operator level) supports simple and straightforward operation of the system for default methods. The MM2 control (for advanced users) is used to set all the parameters of the instrument providing the capability to create new applications. Both software tools incorporate fully automated data evaluation based on the NIST spectra library (National Institute of Standards and Technology), the Bruker CWALib (optional) and TICLib (Toxic Industrial Compounds) or a customer specified library. Air-, surface- and wheel monitoring mode of CWA/TIC: up to 20 substances simultaneously up to 8 characteristic ions per substance MM2 Analysis - GC Run The software tools are compatible with standard WINDOWS systems and standard PCs. Data transfer is provided via an Ethernet-100 interface. Recording chromatograms of complex substance mixtures and identification of the substances via MS spectra libraries (NIST, CWALib, TICLib) Our product line for chemical, biological, radiological and nuclear detection Nuclear & Radiation Detection SVG 2 The new generation of nuclear radiation detectors RAID-XP, RAID-AFM (NC version) Innovative and flexible instruments for NC detection VeroTect Real-time generic biodetector Biological Agent Detection ptd Automated on-site detection of toxins M-BL Automated on-site detection of bacterial and viral pathogens MALDI Biotyper Software tool for reliable identification of unknown microorganisms (BWA) Chemical Warfare Agent Detection Personal Chemical Agent Detector Chemical Emergencies & Demilitarisation MM 2 Mobile Mass Spectrometer for reconnaissance vehicles RAID series Rapid Alarm and Identification Devices based on proven IMS technology RAPID FT-IR Stand-off detector for atmospheric pollutants µraid The compact, flexible and reliable personal detector E 2 M Enhanced Environmental Mass Spectrometer for mobile on-site analysis Mobile-IR Portable FT-IR Spectrometer NIGAS System for non-invasive identification of explosives and CWA

6 Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL CBRN # Technical Specifications Dimensions (LxWxH) 440x307x428 mm Weight 35 kg (Basic Unit) ; 22 kg (Shock Frame) Volume 43 l Ionisation Electron impact, 70 ev Filament Dual Mass stability 0.2 da at all allowed operating conditions Detector Off axis CEM, automatic tuning Vacuum system Ion getter pump < 10-6 mbar (20 l/s, N 2 ), noiseless Inlet Membrane, heated Mass range 1 to 520 da Scan rate 7200 da/s with a resolution of 0.1 da Calibration PFTBA, automatic tuning Selected ion monitoring (SIM) Up to 20 substances simultaneously External power supply 24 V DC ( V) Temperature -20 C C Operate MIL-STD 810F -31 C C Storage MIL-STD 810F Humidity C MIL-STD 810F Vibration, shock, altitude MIL-STD 810F Enclosure protection (IP) Basic unit: IP44, GC: IP43 EMC MIL-STD 461E, IEC (EMC Directive 89/336/EEC) Product safety IEC (EC Low Directive 73/23/EEC) UL94 (Fire Safety) Data handling Separate standard PC, WINDOWS based operating systems Connected via Ethernet-100 Interface Three level software for result visualization, expert modus and service NIST Data evaluation Bruker Detection Division of Bruker Daltonik GmbH Leipzig Germany Phone +49 (341) Fax +49 (341) sales@bdal.de Bruker Detection Division of Bruker Daltonics Ltd. Coventry United Kingdom Phone +44 (2476) Fax +44 (2476) sales@daltonics.bruker.co.uk Bruker Detection Corp. Billerica, MA USA Phone +1 (978) Fax +1 (978) ms-sales@bdal.com

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer NIGAS The Neutron Induced Gamma Spectrometer N B C D e t e c t i o n Po Non-invasive Identification of Explosives and Chemical Warfare Agents Positioning System The NIGAS utilizes Neutron Induced Gamma

More information

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography. Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes

More information

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward Chemical Analysis PIONA+ Analyzer Characterization of Engine Fuels by Hydrocarbon Group Type think forward Gas Chromatography Bruker 450 PIONA+ Analyzer Bruker s innovative PIONA+ TM Analyzer provides

More information

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated

More information

Mobile Mass Spectrometer in daily use Experiences made by non-scientific operators

Mobile Mass Spectrometer in daily use Experiences made by non-scientific operators Mobile Mass Spectrometer in daily use Experiences made by non-scientific operators Franziska Lange, Thomas Ludwig, Bruker Daltonik GmbH HEMS Workshop, Florida, USA September, 211 E 2 M Enhanced Environmental

More information

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D. Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications Mitch Wells, Ph.D. Philip Tackett, Ph.D. HEMS Workshop 2017 FLIR Systems, Inc. Industrial Commercial Government

More information

Application Note CBRNE Detecting Chemical Warfare Agents using the µraid

Application Note CBRNE Detecting Chemical Warfare Agents using the µraid Application Note CBRNE 1825475 Detecting Chemical Warfare Agents using the µraid Abstract The personal protection of military personnel against chemical warfare agents (CWAs) and toxic industrial chemicals

More information

SIFT-MS. technology overview

SIFT-MS. technology overview SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS

More information

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF microtof-q III The bench-mark in accurate mass LC-MS/MS Innovation with Integrity ESI-Qq-TOF The Advantage of Confidence in Routine The microtof-q range is widely acknowledged in setting standards in performance

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

PYCKO SCIENTIFIC LIMITED

PYCKO SCIENTIFIC LIMITED PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent

More information

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Abstract Thermal analysis, by means of a thermo balance (TG), was coupled to an atmospheric pressure chemical ionization

More information

Catalysis CAPABILITIES

Catalysis   CAPABILITIES Catalysis www.extrel.com CAPABILITIES Contents Extrel instruments have been recognized for their exceptional performance by the world s leading researchers for more than 50 years. Reliability and flexibility

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR CONFOCHECK Infrared Protein Analysis Innovation with Integrity FT-IR CONFOCHECK: FT-IR System for Protein Analytics FT-IR Protein Analysis Infrared spectroscopy measures molecular vibrations due to the

More information

IR Biotyper. Innovation with Integrity. Microbial typing for real-time epidemiology FT-IR

IR Biotyper. Innovation with Integrity. Microbial typing for real-time epidemiology FT-IR IR Biotyper Microbial typing for real-time epidemiology Innovation with Integrity FT-IR IR Biotyper - Proactive hospital hygiene and infection control Fast, easy-to-apply and economical typing methods

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

Kore Overview 2013 Dr Barrie Griffiths Kore Technology Ltd.

Kore Overview 2013 Dr Barrie Griffiths Kore Technology Ltd. Kore Overview 2013 Dr Barrie Griffiths Kore Technology Ltd. Kore Technology Ltd: Brief History 1982: Cambridge Mass Spectrometry: a Cambridge Consultants Spin Off formed to sell a TOF-MS-based Laser Ionisation

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

Gruznov, Vladimir. Calhoun: The NPS Institutional Archive Monterey, California. Naval Postgraduate School

Gruznov, Vladimir. Calhoun: The NPS Institutional Archive Monterey, California. Naval Postgraduate School Calhoun: The NPS Institutional Archive Faculty and Researcher Publications Faculty and Researcher Publications 2008-02-01 Gas Analytical Technologies for Physical Protection of Oil and Gas Objects by Vladimir

More information

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research profileanalysis Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research Innovation with Integrity Omics Research Biomarker Discovery Made Easy by ProfileAnalysis

More information

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

RADEAGLET. Lightweight Handheld Radioisotope Identification Device RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear

More information

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF S2 PICOFOX Spectrometry Solutions Innovation with Integrity TXRF S2 PICOFOX True Trace Analysis with XRF for the First Time! You need to know the concentration of trace elements in environmental samples?

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

The RAID-M had the highly sensitive TDI library in Library A of the instrument as shown in Table 1. Table 1: Highly sensitive TDI library in ppb.

The RAID-M had the highly sensitive TDI library in Library A of the instrument as shown in Table 1. Table 1: Highly sensitive TDI library in ppb. Frank Thibodeau, Bruker Detection, Billerica, MA USA Franziska Lange, Bruker Detection, Leipzig, Germany INTRODUCTION Ion Mobility Spectrometry (IMS) is the scientific technique of measuring the drift

More information

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS ENRICO COZZANI DEIS DOCTORATE CYCLE XXIII 18/01/2011 Enrico Cozzani

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

Fast Results Anytime, Anywhere

Fast Results Anytime, Anywhere P R O D U C T N O T E Gas Chromatography/ Mass Spectrometry Key Features Portable, lightweight GC/MS with laboratory equivalent chromatographic resolution Operates under harsh conditions, providing routine

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Martin Okiro and Robert Wohleb VICI Gig Harbor Group Inc, P.O. Box 2657, Gig Harbor,

More information

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are

More information

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications The ABB Atmospheric Emitted Radiance Interferometer AERI provides thermodynamic profiling, trace gas detection, atmospheric cloud aerosol study, air quality monitoring, and more. AERI high level overview

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

Hiden HPR60 Molecular Beam Mass Spectrometer System

Hiden HPR60 Molecular Beam Mass Spectrometer System Hiden HPR60 Molecular Beam Mass Spectrometer System vacuum analysis surface science plasma diagnostics gas analysis HPR60 MBMS Overview The Hiden HPR60 Molecular Beam Mass Spectrometer (MBMS) is a compact,

More information

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra FT-ICR Mass Spectrometer QUANTRA Technical Description September 2003 quantra QUANTRA FT-ICR for the Masses Siemens long-term success in the design of high-quality gas chromatographic equipment is inherent

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is

More information

costech instruments ECS 4010 Elemental Combustion System CHNS-O

costech instruments ECS 4010 Elemental Combustion System CHNS-O instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:

More information

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software NEMC, Washington D.C. August 6 th 2012 Nicola Watson Environmental Specialist Markes International

More information

Odor Detection and Analysis using GC/SAW znose

Odor Detection and Analysis using GC/SAW znose Complimentary Copy Odor Detection and Analysis using GC/SAW znose Edward J. Staples Electronic Sensor Technology 1077 Business Center Circle Newbury Park, California 91320 Ph. 1-805-480-1994 FAX 1-805-480-1984

More information

Mercury Stack Monitor SM-4

Mercury Stack Monitor SM-4 Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix

More information

Petrochemical. Transformer Oil Gas Analysis - TOGA

Petrochemical. Transformer Oil Gas Analysis - TOGA Petrochemical Transformer Oil Gas Analysis - TOGA www.dps-instruments.com The DPS TOGA GC Systems are designed to analyze oil from electrical insulation materials that may have decomposed under thermal,

More information

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219 REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

Process Analytical Technology Diagnosis, Optimization and Monitoring of Chemical Processes

Process Analytical Technology Diagnosis, Optimization and Monitoring of Chemical Processes FRAUNHOFER INSTITUTe FoR Chemical Technology ICT Process Analytical Technology Diagnosis, Optimization and Monitoring of Chemical Processes Process Analytical Technology Diagnosis, Optimization and Monitoring

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

Talk Line-up. MassTech, Inc Columbia Gateway Drive Columbia, Maryland (443) Goals for MT Explorer 50 Development

Talk Line-up. MassTech, Inc Columbia Gateway Drive Columbia, Maryland (443) Goals for MT Explorer 50 Development A Field Deployable Ion Trap Mass Spectrometer with Atmospheric Pressure Interface Arnold Lee *, Alexander Misharin, Konstantin Novoselov, Victor Laiko, Vladimir M. Doroshenko Talk Line-up Goals for MT

More information

Miniaturized Sensor for the Detection of Environmental Pollutants Alexander Graf 1, Ronald Stübner 1, Christian Kunath 1, Sebastian Meyer 1, Harald Schenk 1 1 Fraunhofer Institute for Photonic Microsystems

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

Determination of Volatile Substances Proof of Food Adulteration

Determination of Volatile Substances Proof of Food Adulteration ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of Volatile Substances Proof of Food Adulteration (method: gas chromatography with mass spectrometric detection) Exercise guarantor:

More information

Ion-Chamber Survey Meter OD-02

Ion-Chamber Survey Meter OD-02 Ion-Chamber Survey Meter OD-02 Dose and dose rate meter for measuring the ambient dose equivalent H*(10) and dose rate equivalent dh*(10)/dt as well as the directional dose equivalent H (0,07) and dose

More information

Griffin Analytical Technologies

Griffin Analytical Technologies Performance Characterization and Field Testing of a Portable Tandem Mass Spectrometer John Grossenbacher Mitch Wells, Garth Patterson, Brent Knecht, Dennis Barket, Jr., Brent Rardin, Mark Gregory, Jason

More information

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR Natural Products High Performance NMR Solutions for Analysis Innovation with Integrity NMR NMR Spectroscopy Continuous advancement in Bruker s NMR technology allows researchers to push the boundaries for

More information

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Michael O Leary 1, Jennifer Gough 1, Damian Morrison 1, Alain Creissen 2 1 Waters Corporation, Milford,

More information

CONTINUOUS FINE DUST MEASURING SYSTEM

CONTINUOUS FINE DUST MEASURING SYSTEM CONTINUOUS FINE DUST MEASURING SYSTEM PM 10 - PM 2,5 - PM 1 Particle count distribution DustMonit ENGINEERING SRL Via Paolo Diacono, 1-20133 Milano (MI) - ITALIA Tel ++39.02.26684830 - E-mail : info@conteng.it

More information

Owlstone Nanotech Inc

Owlstone Nanotech Inc Owlstone Nanotech Inc PIDplus Technical Paper USA POC: Mark Brennan mark.brennan@owlstonenanotech.com 400 Rella Boulevard Suite 160 Suffern, NY 10901 Tel: +1 845-533-4225 Fax: +1 845-533-4232 www.owlstonenanotech.com

More information

Plasma Chromatography

Plasma Chromatography Plasma Chromatography Edited by Timothy W. Carr IBM Corporation Hopewell Junction, New York Plenum Press New York and London Contents 1. Instrument Design and Description G. E. Spangler and M. J. Cohen

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

GAS CAMERA MOBILE IMAGING SYSTEM FOR VISUALISING METHANE PLUMES AT DISTANCES BETWEEN 0 M AND 100 M AND MORE

GAS CAMERA MOBILE IMAGING SYSTEM FOR VISUALISING METHANE PLUMES AT DISTANCES BETWEEN 0 M AND 100 M AND MORE 23rd World Gas Conference, Amsterdam 2006 GAS CAMERA MOBILE IMAGING SYSTEM FOR VISUALISING METHANE PLUMES AT DISTANCES BETWEEN 0 M AND 100 M AND MORE Main Author Peter Schwengler, E.ON Ruhrgas AG, Pipelines

More information

Cree XLamp XP-C LEDs Data Sheet

Cree XLamp XP-C LEDs Data Sheet Cree XLamp XP-C LEDs Data Sheet The XLamp XP-C LED combines the proven lighting-class performance and reliability of the XLamp XR-E LED in a package with 80% smaller footprint. The XLamp XP-C LED continues

More information

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment

More information

CapaciTorr HV 200 HIGHLIGHTS

CapaciTorr HV 200 HIGHLIGHTS CapaciTorr HV 200 General Features High pumping speed for all active gases High sorption capacity and increased lifetime Costant pumping speed in HV, UHV and XHV Reversible pumping of hydrogen and its

More information

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL NUCLE A R FORENSIC S INTERN ATION A L TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL This document was designed

More information

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,

More information

IRMS. perspective. Isotope Ratio Mass Spectrometry.

IRMS. perspective. Isotope Ratio Mass Spectrometry. IRMS perspective Isotope Ratio Mass Spectrometry www.nu-ins.com Perspective The Nu Instruments Perspective geometry forms the basis for two state of the art IRMS instruments. Designed for flexibility,

More information

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis vacuum analysis surface science gas analysis plasma diagnostics CATLAB overview The Hiden CATLAB is a catalyst characterisation

More information

The Claviature of Gas Analysis

The Claviature of Gas Analysis The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern

More information

Principles of Gas- Chromatography (GC)

Principles of Gas- Chromatography (GC) Principles of Gas- Chromatography (GC) Mohammed N. Sabir January 2017 10-Jan-17 1 GC is a chromatographic technique utilizes gas as the mobile phase which is usually an inert gas (Hydrogen, Helium, Nitrogen

More information

Extrel is widely respected for the quality of mass spectrometer systems that are

Extrel is widely respected for the quality of mass spectrometer systems that are Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built

More information

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability UV Hound Series Portable UVDOAS Multi-gas Analyzers Multi-Gas Capability Dependable High Quality Air Monitoring Individual VOCs PPB Sensitivity Non-Contact Optical Measurement Automated Reporting Configurable

More information

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System DiscovIR-GPC DiscovIR-GC Deposition and Detection System Application Note 41 Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System ABSTRACT The DiscovIR-GC

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR Analysis of Polymers and Plastics Quality Control & Failure Analysis Innovation with Integrity FT-IR Reliable quality control is essential to achieve a cost-saving production of high quality plastic products.

More information

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS ESPRIT Feature Particle detection and chemical classification Innovation with Integrity EDS Fast and Comprehensive Feature Analysis Based on the speed and accuracy of the QUANTAX EDS system with its powerful

More information

Edgetech Instruments Inc.

Edgetech Instruments Inc. 2015_07_ETI OVERVIEW Rev 3 MADE IN THE USA Edgetech Instruments (ETI) is a USA company based in Massachusetts. We have over 50 years of expertise in the design and manufacture of a comprehensive range

More information

ɣ-radiochromatography

ɣ-radiochromatography nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner

More information

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR Analysis of Polymers and Plastics Quality Control & Failure Analysis Innovation with Integrity FTIR Quality Control for Cost-Efficiency Plastics are used in countless products such as automotive parts,

More information

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + = Application ote #LC-MS 80 Simultaneous Quantitative and Qualitative Measurements in a Single Workflow to Increase Productivity in Primary Drug Metabolism Investigations At-a-Glance n Increased productivity

More information

Product family data sheet

Product family data sheet Cree XLamp XP-E LEDs Product family data sheet CLD-DS18 Rev 12 Product Description The XLamp XP-E LED combines the proven lighting-class performance and reliability of the XLamp XR-E LED in a package with

More information

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note Abstract Area and retention time are the two primary measurements in gas chromatography. The precision with which

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

Hiden Isochema.   Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis Technical Specifications The IGA-1 is designed for gravimetric mixed gas sorption, as well as single component vapor sorption analysis, and powerfully combines the features of the IGA-1, IGA-2 and IGA-3.

More information

Agilent 5977A Series GC/MSD System

Agilent 5977A Series GC/MSD System Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the

More information

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS Designed for Accuracy High resolution quantitative proteomics Innovation with Integrity LC-MS Setting New Standards in Accuracy The development of mass spectrometry based proteomics approaches has dramatically

More information

Cree XLamp XP-E LEDs Data Sheet

Cree XLamp XP-E LEDs Data Sheet Cree XLamp XP-E LEDs Data Sheet The XLamp XP-E LED combines the proven lighting-class performance and reliability of the XLamp XR-E LED in a package with 8% smaller footprint. The XLamp XP-E LED continues

More information

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry Introduction The oil industry requires detailed information on the composition of

More information

XBC300 Gen2. Fully-automated debonder and Cleaner

XBC300 Gen2. Fully-automated debonder and Cleaner XBC300 Gen2 Fully-automated debonder and Cleaner XBC300 Gen2 FULLY AUTOMATED DEBONDER AND CLEANER The SUSS XBC300 Gen2 debonder and cleaner platform is designed for process development as well as high

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

INSTRUMENTAL TECHNIQUE FOR THE DETECTION AND IDENTIFICATION OF RADIOACTIVE, FISSILE AND EXTRA HAZARDOUS SUBSTANCES

INSTRUMENTAL TECHNIQUE FOR THE DETECTION AND IDENTIFICATION OF RADIOACTIVE, FISSILE AND EXTRA HAZARDOUS SUBSTANCES 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China INSTRUMENTAL TECHNIQUE FOR THE DETECTION AND IDENTIFICATION OF RADIOACTIVE, FISSILE AND EXTRA HAZARDOUS SUBSTANCES Nikolay

More information

Technical know-how in thermal analysis measurement

Technical know-how in thermal analysis measurement Technical articles Technical know-how in thermal analysis measurement Evolved gas analysis by thermogravimetry-differential thermal analysis-mass spectrometry (TG-DTA-MS) technique Kazuko Motomura* and

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information