USP<467> residual solvents

Similar documents
Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Residual solvents analysis using an Agilent Intuvo 9000 GC system

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Study of Residual Solvents in Various Matrices by Static Headspace

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method

Headspace Technology for GC and GC/MS: Features, benefits & applications

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Maximizing Sample Throughput In Purge And Trap Analysis

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Application Note. Abstract. Authors. Introduction

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Application. Gas Chromatography February Introduction

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

C146-E209. Headspace Samplers. HS-20 Series

Highly Sensitive and Rugged GC/MS/MS Tool

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Methanol Extraction of high level soil samples by USEPA Method 8260C

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

Optimizing. Abstract: is standardd. procedures. altered to

Solid Phase Micro Extraction of Flavor Compounds in Beer

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

U.S. EPA Method 8270 for multicomponent analyte determination

Author. Abstract. Introduction

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Thermal Desorption Technical Support

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Understanding Gas Chromatography

Determination of Volatile Organic Compounds in Air

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Trajan SGE GC Columns

Routine MS Detection for USP Chromatographic Methods

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

Optimizing Standard Preparation

A Capillary Gas Chromatographic Procedure for the Analysis of Nine Common Residual Solvents in Water-Insoluble Bulk Pharmaceuticals

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Agilent 5977A Series GC/MSD System

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8

Agilent G3212 GC-APCI Source

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

A Technical Guide for Static Headspace Analysis Using GC Inside: Basic Principles of Headspace Analysis

STANDARD OPERATING PROCEDURES

Analysis of BTEX in Natural Water with SPME

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Transcription:

Application Note Pharmaceuticals USP<7> residual solvents Applying the Agilent 977A MSD with the Agilent 797A headspace sampler and Agilent 7890B GC Authors Roger L. Firor and Mike Szelewski Agilent Technologies, Inc. 80 Centerville Rd Wilmington, DE 19808-110 USA Abstract The Agilent 797A headspace sampler coupled to an Agilent 977 Series GC/MSD System was used for the analysis of USP <7> residual solvents at their limit concentration in aqueous solution according to procedure A of the method. Scan data gave repeatability better than. % RSD for Class 1, Class A, and Class B solvents. The multimode inlet (MMI) with an Ultra Inert 1-mm id liner was used for sample introduction from the fused silica headspace transfer line. Several tunes were investigated including Atune and Etune for data acquisition with source and quadrupole temperatures of 0 and 00 C, respectively. Agilent MassHunter Quant software was used for data analysis.

Introduction Quality assurance (QA) labs routinely use United States Pharmacopeia (USP) Method <7> for the analysis of residual solvents 1. This method is used worldwide for quality control. It is harmonized with Guidance for Industry ICH QC Impurities. Residual solvents in pharmaceuticals may remain from the manufacturing process of the active pharmaceutical ingredients (APIs) or final product. Residual solvents do not provide a therapeutic benefit, and should be removed when possible. Monitoring and control of the levels of residual solvents are also done for safety, effect on crystalline form, solubility, bio-availability, and stability. All drug substances, excipients, and products must be monitored. The USP <7> guidelines were followed 1. To take advantage of the advance features of the Agilent 797A headspace sampler, modification and optimization of the headspace parameters were made. Analysis methodologies that deviate from the USP monograph can be used; however, validation and comparison to the original USP procedures may be required. Each class of solvents was run separately for clarity. USP <7> specifies the following three procedures for Class 1 and Class residual solvents: Procedure A: Identification and limit test Procedure B: Confirmatory test Procedure C: Quantitative test Procedure A uses a G phase (Agilent columns, VF-ms or DB ), and Procedure B uses a G1 phase (HP-INNOWax). In general, analytes that coelute on one of these phases do not coelute on the other. Since the primary objective of this Application Note centers on evaluating analytical sensitivity and repeatability, only the VF-ms column was used. Other configurations using dual FIDs ( and INNOWax columns) or FID/MSD are possible, and have previously been described,,,. The headspace-based method has historically suffered from poor repeatability when analyzing solvents at or below their USP <7> limit concentrations. Use of advanced pneumatics, excellent thermal zone control, and precise timing translates into better repeatability and precision for residual solvent analysis. Features of the Agilent 977A Series GC/MSD System, including an inert extractor source also contribute to improved repeatability. GC-headspace-MSD systems can offer additional capabilities for residual solvent analysis, especially when unknowns are encountered. Using SIM, coelution problems are overcome and better analytical sensitivity can be achieved. Experimental This Application Note used USP Method <7> Procedure A to investigate the performance of the 977 Series GC/MSD System with the 7890B-797A. The Agilent 7890B GC was configured with a multimode inlet (MMI). A 1-mm id deactivated straight liner (p/n 190 07) was used. Class 1, Class A, and Class B residual solvents were prepared at their limit concentrations in purified water. Clean organic-free water is important for good standard preparation. There were 0 ml solutions of each class prepared at their final concentrations, then ml was transferred into 0 ml vials using an auto pipette. Only PTFE lined septa were used. Salt was not added to the solution. Agilent part numbers for the residual solvent standards are: Class 1: p/n 190-090 Class A: p/n 190-09 Class B: p/n 190-01 The Agilent 797A headspace sampler was connected to the inlet using 0. mm id deactivated fused silica tubing. Interface to the MMI was through the septum. A 0 m, 0. mm id VF ms column was used for this work, as it represents a good compromise between resolution, speed, capacity, and ease-of-use.

Vial pressure was controlled from a pneumatic control module (PCM) in the 797A headspace sampler. The carrier flow was routed from the inlet EPC to the headspace sampler and back to the 7890B inlet. EPC-controlled sampling steps give the user control over all aspects of headspace vial sampling in a concise and reproducible method with minimal carryover. Barometric pressure compensation is also implemented in the EPC modules. Parameters can be set from the 797A headspace sampler keyboard or integrated headspace control software. Figure 1 shows the headspace vial sampling pane from the MSD ChemStation. The use of controlled venting in the 797A headspace sampler allows the user flexibility over the final vial pressure when filling the sample loop. This control leads to better repeatability and, depending on the analyte k (partition coefficient) value, it can also enhance sensitivity. Three modes of vial pressurization are possible in the 797A headspace sampler: Flow limited to pressure To pressure, controlled at flow of 00 ml/min Fixed volume All experiments used the to pressure mode. Figure 1 shows a MSD ChemStation pane for setting the vial sampling parameters. Note that HS vial pressure ramps from 1 to 10 psi for headspace sampling. Figure 1. Parameters are shown for 0-mL vials, where the HS vial is pressurized to 1 psi, and vented to 10 psi at a rate of 0 psi/min.

A moisture trap designed to reduce condensation is plumbed in the vent line and is purged between runs. The headspace sample loop is 1.0 ml. Helium is used for carrier and vial pressurization. Table 1 gives the application-specific parameters. Agilent MassHunter Software The 977 Series GC/MSD system introduction includes the ability to use Agilent MassHunter (MH) software similar to that on the Agilent 7000B GC/MS/MS. The data acquisition has been improved, especially in the ease of setting up SIM tables. SIM, scan, and temperature parameters are on a single screen for quick review. Current MSD ChemStation acquisition methods can be imported and used directly in MH. Data analysis is accomplished using either MH Qualitative Analyses (Qual) or MH Quantitative Analysis (Quant). This Application Note used Qual for the chromatogram displays. Quant was used for compound integration, and subsequent RSD calculations were done in Excel. Current MSD ChemStation quant databases (calibration tables) can easily be converted for use in MH Quant with the included Converter. Using MH Qual and Quant is not required. The 977 Series GC/MSD system acquisition software automatically saves data in both MH format and classical MSD ChemStation format. Laboratories have a choice in data analysis packages. This work used the following software versions: MSD ChemStation B.07.00 acquisition MassHunter B.0.01 Quant Headspace control software B.01.0 Table 1. System parameters for the analysis of residual solvents. Parameter Value Gas chromatograph Agilent 7890B GC Injection port Multimode Inlet Liner 1-mm id Ultra Inert (p/n 190-07) Inlet temperature 10 C Inlet flow Constant flow, 1. ml/min Split ratios 0:1, 100:1 Oven program 0 C ( minutes) to 0 C ( minutes) at 18 C/min Column VF-ms, 0 m 0. mm, 1. µm MSD Agilent 977A Series GC/MSD System Transfer line 190 C MS source 0 C MS Quad 00 C Tune etune, atune, and bfb tunes used Scan 9 to 10 amu, 10. scans/sec Gain factor 1.00 Headspace Agilent 797A Headspace Sampler Vial pressurization gas Helium Loop size 1.0 ml Vial standby flow 0 ml/min Transfer line 0.-mm deactivated fused silica HS Oven temperature 8 C HS Loop temperature 8 C HS Transfer line temperature 100 C Vials 0 ml, PTFE/silicone septa Vial shaking Level 1 Vial fill mode To pressure Vial fill pressure 1 psi Loop fill mode custom Loop ramp rate 0 psi/min Loop final pressure 10 psi Loop equilibration time 0.0 minutes Carrier control mode GC carrier control Vent after extraction ON Post injection purge 100 ml/min for minutes

Results and discussion Figure shows the TIC for the Class1 residual solvents at their limit concentrations prepared in pure water. Class 1 solvents benzene and 1,-dichloroethane are baseline separated on the VF-ms column. Table shows that scan RSDs are reported for all classes, and SIM RSDs for Class A. Most RSDs are below. %. Those with higher values generally have low k s. Sample preparation variability can have a larger impact on low k solvents. Other solvent systems such as dimethyl sulfoxide (DMSO), dimethyl acetamide (DMAC), 1,-dimethyl-- imidazolinone (DMI), or mixed, such as DMSO/water, will change the response. RSDs should be equal if not better than those shown in this work using an aqueous diluent. Counts (%) 10 1 8 7 1 0 1 1.1,1-Dichloroethene.1,1,1-Trichloroethane.Carbon tetrachloride.benzene.1,-dichloroethane.8...0..8...0..8 7. 7. 8.0 8. 8.8 Acquisition time (min) Figure. TIC for the Class 1 residual solvents at their limit concentrations prepared in pure water. Table. Residual solvent Class1, Class A, and Class B repeatability. Scan data are shown for all classes, and SIM data for Class A. Prepared at limit concentrations in aqueous diluent. Compound USP limit (ppm) Scan RSD (%) SIM RSD (%) Class 1 (n = 8) 1,1-Dichloroethene 8 0.9 1,1,1-Trichloroethane 1,00 1.9 Carbon tetrachloride 1. Benzene 0.7 1,-Dichloroethane 0.9 Class A (n = 10) Methanol,000.8. Acetonitrile 10.. Dichloromethane 00.. trans-1,-dicloroethene 1,870.. cis-1,-dichloroethene 1,870.1.1 Tetrahyrofuran 70.0. Cyclohexene,880.7 1. Methylcyclohexane 1,180. 1. 1,-Dioxane 80.. Toluene 890 0.7.0 Chlorobenzene 0 1.9.1 Ethylbenzene,170 1.9.1 m-xylene, p-xylene,170.1 1.8 o-xylene,170.1 1.8 Class B (n = 9) Hexane 90. Nitromethane 0.8 Chloroform 0. 1,-Dimethoxyethane 100.7 Trichloroethene 80. Pyridine 00.9 -Hexanone 0. Tetralin 100.

Figure shows a representative TIC for Class A solvents. Figure shows a zoom-in on the chromatogram to illustrate the small peaks. Counts (%) 10 1.0 0.9 0.8 0.7 0. 0. 0. 0. 1. Methanol. Acetonitrile. Dichloromethane. trans-1, Dichloroethene. cis-1,-dichloroethene. Tetrahydrofuran 7. Cyclohexane 8. Methylcyclohexane 9. 1,-Dioxane 10. Toluene 11. Chlorobenzene 1. Ethylbenzene 1. m-xylene 1. p-xylene 1. o-xylene 7 8 10 1,1 1 11 1 0. 0.1 0 1 9 7 8 9 10 11 Acquisition time (min) Figure. Representative TIC for Class A solvents. Counts (%) 10 1 1. 1. 1. 1. 1. 1.1 1.0 0.9 0.8 0.7 0. 0. 0. 0. 0. 0.1 0....8.0....8.0....8.0....8 7.0 7. 7. 7. 7.8 8.0 8. 8. Acquisition time (min) Figure. A zoom-in on the chromatogram to illustrate compounds with low response: acetonitrile and 1,-dioxane. See Figure for peak numbers. 7 8 9

Figure and Table respectively, show a SIM chromatogram and SIM ions used. This analysis used a split ratio of 100 to 1. The faster sweep of the liner leads to greatly improved methanol peak symmetry. Even at this high split ratio, signal-to-noise (S/N) is excellent. Counts (%).0 1.8 1. 1. 1. 1.0 0.8 1. Methanol. Acetonitrile. 1,-Dioxane 1 0. 0. 0. 1 0..... 7 7. 8 8. 9 9. 10 10. 11 Acquisition time (min) Figure. Class A SIM chromatogram and SIM group time brackets used. Table. SIM groups for Class A solvents. Group Compound SIM ions 1 Methanol 1,9 Acetonitrile Dichloromethane trans-1,-dicloroethene 9,1,8,8,9,98 cis-1,-dichloroethene Tetrahyrofuran Cyclohexene,71,7,8,9,98 Methylcyclohexane 1,-Dioxane 8,8,88,98 Toluene 91,9 Chlorobenzene Ethylbenzene m-xylene, p-xylene, o-xylene 91,10,11,11 7

Figure shows the SCAN/SIM setup pane (Class A) from MSD ChemStation acquisition. Figure 7 shows a typical SIM run for Class B solvents. The split ratio is 0:1. Good S/N is seen for nitromethane. Pyridine, always a difficult solvent due to its polarity, shows minimal peak tailing on the VF- ms column. Table gives the SIM parameters used, and Figure 8 shows a setup pane from the MSD ChemStation. Coelutions can occur on the phase when all three classes of solvents are considered. This usually is dealt with in FID systems using a dual column configuration where the second channel uses a INNOWax column yielding a different elution order compared to the phase. Using the MSD in SIM overcomes this problem when using just the phase. For new drug development and scale up of new formulations, the 977 Series GC/MSD System can be a powerful tool. This system is also well suited for the development of generic methods that do not need to follow USP <7> guidelines. When unknown peaks or solvents are present, this system may be the best solution to use. Sensitivity in SIM is also a major advantage when looking for low level impurities either known or unknown. Figure. The SCAN/SIM setup pane (Class A) from MSD ChemStation acquisition. 8

Table. SIM groups for Class B solvents. Group Compound SIM ions 1 Hexane,7 Nitromethane,1 Chloroform 8,8 Dimethoxyethane,0 Trichloroethene 10,1 Pyridine, -Hexanone,8,79,8 7 Tetralin 10,1 Counts (%) 8 7. 7..... 1. 1 0. 0-0. 1 1 7... 7 7. 8 8. 9 9. 10 10. 11 11. 1 1. 1 1. 1 1. Acquisition time (min) 7 1. Hexane. Nitromethane. Chloroform. 1,-Dimethoxyethane. Trichloroethene. Pyridine 7. -Hexanone 8. Tetralin 8 Figure 7. A typical SIM run for Class B solvents. Figure 8. SCAN/SIM setup pane from the MSD ChemStation for Class B solvents. 9

Conclusion The Agilent 977 Series GC/MSD System/Agilent 7890B GC/Agilent 797A headspace sampler is capable of outstanding repeatability for the analysis of residual solvents. Use of the MSD is a powerful analytical tool for investigation of solvent impurities in pharmaceutical starting materials including the API and excipients. It is especially useful in drug discovery and process scale-up where unknowns must be identified. In the 797A headspace sampler, an inert sample path, thermal zones with stability of better than ±0.1 C of setpoint, and flexible EPC-controlled vial sampling all contribute to the system's performance. Carryover was nonexistent in this system. User programmable (flow rate and times) needle/loop purge, and vent line purge are used to effectively clean the system between runs. The methods outlined in this work illustrate several possible strategies for the analysis of residual solvents using the 977 Series GC/MSD system. Laboratories should perform system suitability studies and validate their proposed methods according to USP or ICH guidelines. The MSD configuration is particularity useful when the need for unknown identification arises, or in QA labs for unambiguous confirmation. References 1. USP -NF 7, General Chapter USP <7> Organic volatile impurities, United States Pharmacopeia. Pharmacopoeia Convention Inc., Rockville, MD, 8/009.. Gudat, A. E.; Firor, R. L. Improved Retention Time, Area Repeatability, and Sensitivity for Analysis of Residual Solvents, Agilent Technologies Application Note, publication number 989-079EN.. Firor, R. L. Analysis of USP<7> Residual Solvents with Improved Repeatability Using the Agilent 797A Headspace Sampler, Agilent Technologies Application Note, publication number 990 7EN.. Tienpont, B.; et al. Analysis of USP<7> Residual Solvents using the Agilent 797A Headspace Sampler with the Agilent 7890B Gas Chromatograph, Agilent Technologies Application Note, publication number 991-18EN.. Firor, R. L. Fast Analysis of USP 7 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System, Agilent Technologies Application Note, publication number 990-09EN.. Firor, R. L. Optimizing Vial Pressurization Parameters for the Analysis of USP<7> Residual Solvents Using the 797A Headspace Sampler, Agilent Technologies Application Note, publication number 990-910EN. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 018 Printed in the USA, March 9, 018 991-079EN