High-energy proton induced damage study of scintillation light output from PbWO 4 calorimeter crystals

Similar documents
Summary on crystal damage from hadrons

INORGANIC crystal scintillators are widely used in high

High-energy proton induced damage in PbWO 4 calorimeter crystals

A Study on Radiation Damage in PWO-II Crystals

Overview of validations at LHC

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

The CMS ECAL Laser Monitoring System

Neutron pulse height analysis (R405n)

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Proof-of-principle of a new geometry for sampling calorimetry using inorganic scintillator plates

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Upgrade of the CMS Forward Calorimetry

arxiv:physics/ v1 3 Aug 2006

Hodoscope performance for the cosmic ray set-up of the MDT-BIS chamber Beatrice

arxiv: v1 [physics.ins-det] 3 Feb 2011

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

arxiv: v2 [nucl-ex] 6 Oct 2008

THE main physics motivation for building the Compact

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Y2 Neutrino Physics (spring term 2017)

Studies of Hadron Calorimeter

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

CMS Conference Report

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal

New Results from the DREAM project

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Light ion recoil detector

Measurements of the Minimum Bending Radius of Small Diameter Scintillating Plastic Fibres

CMS ECAL status and performance with the first LHC collisions

Influence of radiation damage on the performance of a lead/scintillator calorimeter investigated with 1 6 GeV electrons

Hands on Project: Large Photocathode PMT Characterization

Dual readout with tiles for calorimetry.

M. Diemoz INFN Sezione di Roma, P.le A. Moro 2, Roma, Italy

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Chapter 4 Scintillation Detectors

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Detection and measurement of gamma-radiation by gammaspectroscopy

GaN for use in harsh radiation environments

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Simulation for LHC Radiation Background

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Future prospects for the measurement of direct photons at the LHC

ATLAS Tile Calorimeter Calibration and Monitoring Systems

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PHYS 3446 Lecture #12

Particle Energy Loss in Matter

Optical transmission radiation damage and recovery stimulation of DSB:Ce 3+ inorganic scintillation material

Scintillation Detector

Radiation Induced Color Centers and Light Monitoring for Lead Tungstate Crystals

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

Measurement of secondary particle production induced by particle therapy ion beams impinging on a PMMA target

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Dario Barberis Evaluation of GEANT4 Electromagnetic and Hadronic Physics in ATLAS

physics/ Sep 1997

Particle Energy Loss in Matter

Results from Silicon Photo-Multiplier neutron irradiation test

Muon reconstruction performance in ATLAS at Run-2

SCINTILLATION DETECTORS AND PM TUBES

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

October 4, :33 ws-rv9x6 Book Title main page 1. Chapter 1. Measurement of Minimum Bias Observables with ATLAS

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Simulation and validation of the ATLAS Tile Calorimeter response

New irradiation zones at the CERN-PS

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Scintillating Fibre and Radiation Damage Studies for the LHCb Upgrade

Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Radiation Detection and Measurement

John Ellison University of California, Riverside. Quarknet 2008 at UCR

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

MEASURING THE LIFETIME OF THE MUON

READINESS OF THE CMS DETECTOR FOR FIRST DATA

This paper should be understood as an extended version of a talk given at the

Geant4 simulation for LHC radiation monitoring

A Complete Simulation of a Triple-GEM Detector

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Hands on LUNA: Detector Simulations with Geant4

SCINTILLATORS AND WAVELENGTH SHIFTERS FOR THE DETECTION OF IONIZING RADIATION *

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

BSO Crystals for the HHCAL Detector Concept

Cosmic Muon Shower Study with QuarkNet

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

NEW TYPES OF LEAD TUNGSTATE CRYSTALS WITH HIGH LIGHT YIELD

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Longitudinal Double Spin Asymmetry in Inclusive Jet Production at STAR

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

arxiv: v1 [physics.ins-det] 7 Dec 2018

Radioactivity and Ionizing Radiation

arxiv: v1 [physics.ins-det] 29 Jun 2011

PoS(PhotoDet 2012)010

arxiv: v1 [physics.ins-det] 24 Jan 2010

Measuring Cosmic Ray Muon Decay Constant and Flux

Transcription:

ETHZ IPP PR 2006 01 April 11th, 2006 arxiv:physics/0604102 v1 12 Apr 2006 High-energy proton induced damage study of scintillation light output from PbWO 4 calorimeter crystals P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss Institute for Particle Physics, ETH Zurich, 8093 Zürich, Switzerland Abstract Eight PbWO 4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 10 13 p/cm 2. The damage recovery in these crystals, stored in the dark at room temperature, has been followed for over a year. Comparative irradiations with 60 Co photons have been performed on seven other crystals using a dose rate of 1 kgy/h. The issue whether hadrons cause a specific damage to the scintillation mechanism has been studied through light output measurements on the irradiated crystals using cosmic rays. The correlation between light output changes and light transmission changes is measured to be the same for proton-irradiated crystals and for γ-irradiated crystals. Thus, within the precision of the measurements and for the explored range of proton fluences, no additional, hadron-specific damage to the scintillation mechanism is observed. Submitted to Elsevier Science

1 Introduction The way large hadron fluxes affect PbWO 4 crystals has become relevant with the construction of LHC [1]. For the CMS experiment, charged hadron fluences have been calculated [2] for an integrated luminosity of 5 10 5 pb 1, which nominally corresponds to 10 years of running at LHC, yielding in the electromagnetic calorimeter (ECAL) barrel up to 10 12 and in the end caps 10 14 charged hadrons/cm 2. It had to be ascertained whether such fluxes cause a specific, possibly cumulative, damage, and if so, what its quantitative importance is and whether it only affects light transmission (LT) or also the scintillation mechanism. A hadron-specific damage could arise from the production, above a 20 MeV threshold, of heavy fragments with up to 10 µm range and energies up to 100 MeV, causing a displacement of lattice atoms and energy losses, along their path, up to 50 000 times the one of minimum-ionising particles. The damage caused by these processes is likely to be different from the one caused by ionising radiation and could be cumulative. In a study we have published recently [3], the primarily investigated quantity was the damage to light transmission, because it can be measured very accurately. Furthermore, all damage observed in earlier tests [4, 5] could always be ascribed to the ionising dose associated with the hadron flux, apart from some indication for a hadron-specific damage in BGO, which can be extracted [6] from existing data. None of the previous tests on lead tungstate was extended however to the full integrated fluences expected at the LHC. Eight CMS production crystals of consistent quality were irradiated at the IRRAD1 facility of the CERN PS accelerator T7 beam line [7] in a 20 GeV/c proton flux of either 10 12 p cm 2 h 1 (crystals a, b, c, d, h) or of 10 13 p cm 2 h 1 (crystals E, F, G) 1). These crystals have the shape of truncated pyramids with nearly parallelepipedic dimensions of 2.4 2.4 cm 2 and a length of 23 cm. The exact fluxes and fluences each crystal was exposed to are listed in Ref. [3]. The maximum fluence, of 5.4 10 13 p/cm 2, was reached for crystal a. To disentangle the contribution to damage from the associated ionising dose, complementary 60 Co γ-irradiations were performed at a dose rate of 1 kgy/h on further seven crystals (t, u, v, w, x, y, z) at the ENEA Casaccia Calliope irradiation facility [8], since a flux of 10 12 p cm 2 h 1 has an associated ionising dose rate in PbWO 4 of 1 kgy/h. The maximum dose of 50.3 kgy was reached for crystal v, just a factor 2 below the dose reached in proton irradiations, which for a was 97.5 kgy. The study of transmission damage revealed that proton irradiation decreases the light transmission for all wavelengths and moves the ultra-violet LT band-edge to longer wavelengths, as can be seen in Fig. 9 of Ref. [3]. In γ-irradiated crystals, the band-edge does not shift at all, even after the highest cumulated dose: only the well-known absorption band [9] appears around 420 nm. These data demonstrate the qualitatively different nature of protoninduced and γ-induced damage. The correlation we found, between the induced absorption coefficient at the peak of scintillation-emission wavelength, µ IND (420 nm) [3], and fluence, is consistent with a linear behaviour over two orders of magnitude, showing that proton-induced damage in PbWO 4 is predominantly cumulative, unlike γ-induced damage, which reaches equilibrium [9, 10]. The data for µ IND versus light wavelength for protonirradiated crystals show a λ 4 dependence, which is absent in γ - irradiated crystals. This is an indication of Rayleigh scattering from small centres of severe damage, as it might be caused by the high energy deposition of heavily ionising fragments along their path, locally changing the crystal structure. Taking into account the difference in composition and energy spectra between 20 GeV/c protons and CMS, simulations indicate that the test results cover the CMS running conditions up to a pseudorapidity of 2.6. An experimental confirmation is expected from a planned pion-irradiation of PbWO 4, closer to the CMS particle spectrum average [3]. However, the relevant quantity for detector operation is the scintillation light output (LO). Detector calibration through a light injection system, as foreseen by CMS [11], can only work, as long as changes in light output are all due to changes in light transmission. This had been verified extensively so far for ionising radiation, but for high hadron fluxes it still had to be established: the present work deals with this question. In the following, the measurement setup and technique are described, the data analysis is explained, and results are given, in comparison, for proton-irradiated crystals and for γ -irradiated crystals. 2 The setup Light output from a crystal is commonly measured in the laboratory using photons from a 60 Co or 137 Cs source to excite scintillation. The light output is then determined from the position, in the spectrum, of the photoelectric peak produced by photons which deposit all their energy in the crystal. For lead tungstate crystals, the light output 1) Labels prime (respectively double-prime ) will be used after the letter identifying the crystal, in order to indicate a second (or third) irradiation of the same crystal. 1

is modest, 10 photoelectrons/mev of incoming particle energy, as detected on the bialkali photocathode of a photomultiplier (PM) covering the whole back face of the crystal. Thus, the photoelectric peak is broadened by statistical fluctuations and merged with the Compton edge. In the present study, the hadron-irradiated crystals will remain radioactive for years, and thus act as sources for γ and β emission over an extended range of energies, peaked at the lowest detectable values and tailing off towards larger ones. The photoelectric peak from any common laboratory γ source is swamped by this spectrum, and a different method of LO determination had to be adopted. As an alternative, cosmic muons passing a crystal transversely were used. These muons deposit 24.5 MeV in the crystal, an energy deposit which is well above all γ energies emitted by radioactive isotopes. Using these muons to excite scintillation gave us a light output well above the crystal s own background. An individual crystal was placed in horizontal position, with plastic scintillator counters above and below, to select nearly vertical muons. Since only a relative measurement of LO loss was sought, large rectangular plastic scintillators were used, 24 cm long and 23 cm wide, sitting at 22 cm distance above and below the crystal. These counters yielded a large angular acceptance, allowing for muons traversing the crystal at angles between 0 o and 37 o from the vertical, leaving thus an energy deposit E dep between 24.5 MeV and 30.6 MeV. 3 Measurements and systematics entries 80 70 60 50 40 30 20 10 0 crystal F 0 200 400 600 800 1000 ADC channel Figure 1: Spectrum for crystal F. For LO measurements, each crystal was wrapped in Tyvek TM [12] on all sides but its large end, which was coupled via an air gap to a Philips XP2262B bialkali-photocathode PM equipped with a standard CERN base type 4238. A PVC centering tube was used for reproducible positioning. The photomultiplier was operated at a gain of 10 8. The current pulses from its anode were fed into an Analog-to-Digital converter 2249W from LeCroy, which has a sensitivity of 0.25 pc. Data acquisition was performed with a PC running a Labview 7.0 virtual instrument, interfaced via a HYTEC 1331 controller [13] to a CAMAC crate. The data acquisition was triggered by a coincidence of the signals in both plastic scintillator counters. A CAMAC-controlled Programmable Dual Gate and Delay Generator LeCroy 2323A defined a 200 ns ADC charge integration time. The acquisition of a spectrum with sufficient statistics for one LO measurement typically took 24 h, yielding approximately 8000 events in the muon energy deposition peak. The ambient temperature was recorded at the beginning and at the end of each measurement, since the lead tungstate LO changes by 2%/ o C [14, 11] at room temperature, and the light output determined for each run was corrected offline to its value at 18 o C. The uncertainty on the correction, coming from possible, undetected fluctuations of temperature in the crystal over the duration of a run, amounts to 0.4% and is negligible compared to the other error sources affecting the LO determination, as discussed below. The anode signal was attenuated at the input, by typically 24 db, for the acquisition of a muon spectrum. Keeping the same PM high voltage, the stability of the setup, from the PM multiplication chain to the ADC, was monitored by 2

periodically acquiring the spectrum of single photoelectrons thermally emitted by the photocathode. In this case, the anode signal from the PM coupled to the crystal was used for self-triggering, with no attenuation before the ADC input, and the discriminator threshold was set low enough to see the valley below the single photoelectron peak, according to the method we described in Ref. [10]. Pedestal data were acquired at the beginning of every run, and subtracted on a run-by-run basis. Since we could not exclude a priori that the crystal radioactivity would affect the detection efficiency of the setup over time, we also periodically monitored the stability of the setup by acquiring the cosmic muons spectrum from a non-irradiated reference crystal, and, when necessary, corrected all data for relative gain changes. This procedure allowed to monitor the whole light detection chain, including the photocathode quantum efficiency. As an example, Figure 1 shows a cosmic muons spectrum for F after an irradiation with 9.83 10 12 p/cm 2, where the crystal experienced a considerable damage in light transmission, corresponding to an induced absorption coefficient of 3 m 1. The sharp rise which is clearly visible below channel 100 is due to light produced by the radioactivity of the crystal. 4 Results LO (a.u.) 260 240 220 before irradiation foam wrapping 200 180 160 140 chipping foam + felt pads accidental light exposure 0 50 100 150 200 250 300 350 400 relative time (days) Figure 2: Light output change over time for crystal G, where the long-term, natural room-temperature recovery of damage can be observed, along with some accidental changes (see text). Great care had to be given to sources of systematic errors in the measurements. For precise relative LO loss measurements, the geometrical acceptance of each crystal for triggered muons was kept constant from one measurement to the next, to ensure keeping the average muon energy deposit, < E dep >, always at the same value. This was achieved by placing each crystal every time in the same position and orientation in the setup. The remaining uncertainty has been evaluated from the fluctuation of the various LO measurements for the reference crystal. This was done separately for the period where proton-irradiated crystals were measured, whose irradiations were performed between May and October 2003, and for the period where γ-irradiated crystals were monitored, which were exposed to protons in May 2004 and measured over the following 7 months. Reproducibility of positioning was significantly improved over time as a result of the learning process. The corresponding, relative uncertainty on LO measurements was determined as the σ of the distribution of values for the reference crystal. For γ-irradiated crystals it amounts to 1.7% and for proton-irradiated ones, to is 2.4%, except on the data before irradiation for crystals a and F, which were taken before monitoring the system stability with frequent reference crystal measurements, and where it amounts to 3.8%. This uncertainty affects every LO measurement, and it is thus added in quadrature to the statistical errors. However, the LO change, which we want to correlate with the damage to light transmission, is determined as the ratio between light output at a given time after irradiation and the light output before irradiation. The uncertainty on the light output measurement before irradiation thus affects, as an overall scale uncertainty, the whole set of data for each crystal. 3

LO loss 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 proton-irradiated crystals a a b c d E F G h 10-1 1 10 µ IND (420 nm) (m -1 ) LO loss 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 γ -irradiated crystals t u v w x y z 10-1 1 10 µ IND (420 nm) (m -1 ) Figure 3: Correlation between µ IND (420 nm) and LO loss for proton-induced (top) and γ-induced (bottom) damage. See the text for the systematic scale uncertainty on the data (not shown). Direct contact was initially used between crystal and PM face, but it resulted, for the reference crystal and for the proton-irradiated ones, in the chipping of a few corners, due to the repeated positioning of the crystals in the setup. This caused a small, but noticeable loss of collected light with respect to the natural, room-temperature damage recovery (see Fig. 2), since the surface of the large face was slightly reduced by the accident. To reduce the risk of chipping, a sheet of polyethylene foam was thus first wrapped around the Tyvek, to protect the long chamfers. This resulted in a small rise of LO signal (see Fig. 2) because of the slight change of crystal positioning on the photocathode, whose efficiency is position-dependent. Further, four tiny felt pads were applied, as a protection, to the corners of the big end face, masking 6% of it. The LO decreased slightly this way, due to the reduced area for light collection (Fig. 2). Since the amount of chipping was different from crystal to crystal, and since the changes cannot be necessarily disentangled from damage recovery, no correction was applied to the data for these systematic shifts, but we include a relative systematic uncertainty of 4% from this effect on the LO measurements for p- irradiated crystals. The crystals irradiated with photons are not affected by this uncertainty, since the protection was adopted before the reference data taking prior to irradiation. Furthermore, for crystal G one should notice in 4

Fig. 2 the LO difference between the value at 180 days and the one at 270 days after irradiation: this rise is due to a step in the damage recovery, as it can be appreciated in the corresponding LT recovery data of Fig.11 in Ref. [3], which originated from an accidental, prolonged exposure of the crystal to fluorescent room light. The correlation between µ IND (420 nm) and LO loss is shown at the top of Fig. 3 for all proton-irradiated crystals. One should notice the very important damage for a, which reached µ IND (420 nm) 15 m 1 after a fluence of 5.4 10 13 p/cm 2 and experienced a corresponding LO loss of nearly 96%. The correlation for all γ-irradiated crystals is shown in the bottom part of Fig. 3. The overall, relative, systematic scale uncertainty affecting the results amounts to 1.7% for γ-irradiated crystals and to 4.7% for p-irradiated ones, except for crystals a and F, where it is 5.5%. Within the precision of our measurements, a clear correlation is observed between loss of light transmission, expressed through µ IND (420 nm), and the relative LO loss, both, for hadron-irradiated crystals and for γ irradiated ones. Furthermore, the two correlations are compatible within the precision of our measurements. Thus, in the range of proton fluxes and fluences used for the present irradiations, no hadron-specific alteration to the crystal scintillation properties has been observed. 5 Conclusions A set of lead tungstate crystals of CMS production quality have been exposed to 20 GeV/c proton fluxes up to 5.4 10 13 p/cm 2. For comparison, a different set of similar quality lead tungstate crystals have been exposed to an equivalent amount of 60 Co γ-radiation in terms of ionising dose rate and dose. Measurements of changes in scintillation light output have been performed and correlated with light transmission changes. Within the precision of our measurements, the correlations for proton-irradiated and for γ-irradiated crystals are compatible. Thus, for the crystals tested, and within the range of particle fluxes and fluences considered, we do not observe any additional, hadron-specific alteration of lead tungstate scintillation properties. Acknowledgments We are indebted to R. Steerenberg, who provided us with the required PS beam conditions for the proton irradiations. We are deeply grateful to M. Glaser and F. Ravotti, who helped us in operating the irradiation and dosimetry facilities. The support and practical help of S. Baccaro and A. Cecilia during the γ-irradiations at ENEA-Casaccia were essential and are gratefully acknowledged, as is the contribution of E. Auffray who provided us with the crystals after having characterised their γ-radiation hardness at the Geneva Hospital. Mika Huhtinen contributed in an invaluable way [3] to the crystal irradiations and to the work on LT damage. References [1] F. Nessi-Tedaldi, Int. J. Mod. Phys. A20 (2005) 3826-3829. [2] The CMS Collaboration, The Tracker Project Technical Design Report, CERN/LHCC 98-6, CMS TDR 5, CERN, Geneva (Switzerland, 1998). [3] M. Huhtinen, P. Lecomte, D. Luckey, F. Nessi-Tedaldi, F. Pauss, Nucl. Instrum. Meth. A545 (2005) 63-87. [4] V. A. Batarin et al., Nucl. Instrum. Meth. A530 (2004) 286-292. [5] E. Auffray et al. CMS-NOTE-1998-069, CERN, Geneva (Switzerland, 1998). [6] F. Nessi-Tedaldi, Crystals for high-energy calorimeters in extreme environments, To be published in Proc. 9th ICATPP Conf. on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications, Como (Italy, 2005), Preprint ETHZ-IPP-PR-2005-03 (2005). [7] M. Glaser et al., Nucl. Instrum. Meth. A426 (1999) 72-77. [8] S. Baccaro et al., γ Irradiation facility at ENEA-Casaccia Centre (Roma), ENEA report RT/2005/28/FIS, ISSN/0393-3016, ENEA Casaccia, Rome (Italy, 2005). [9] R. Y. Zhu, Nucl. Instrum. Meth. A413 (1998) 297-311. [10] H. F. Chen, K. Deiters, H. Hofer, P. Lecomte, F. Nessi-Tedaldi, Nucl. Instrum. Meth. A414 (1998) 149-155. 5

[11] The CMS Collaboration, The ECAL Technical Design Report, CERN/LHCC 97-33, CMS TDR 4, CERN, Geneva (Switzerland, 1997). [12] Tyvek TM is a product of DuPont. [13] Hytec Electronics Ldt, Reading, Berkshire (England). [14] I. Dafinei, E. Auffray, P. Lecoq and M. Schneegans, Mat. Res. Soc. Symp. Proc. 348 (1994) 99-104. 6