JWH-018 and JWH-022 as Combustion Products of AM2201

Similar documents
Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Determination of Volatile Substances Proof of Food Adulteration

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

5Cl-AKB48 and 5Br-AKB48

A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

The AccuTOF -DART 4G: The Ambient Ionization Toolbox

CHAPTER 6 GAS CHROMATOGRAPHY

5-METHOXY- -METHYLTRYPTAMINE Latest revision: June 20, 2005

5-METHOXY-N,N-DIISOPROPYLTRYPTAMINE Latest Revision: June 20, 2005

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Method - Determination of aromatic amines in mainstream cigarette smoke

Understanding Gas Chromatography

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

GAS CHROMATOGRAPHY (GC)

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Gas Chromatography. Introduction

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Sulfotepp impurities in Chlorpyrifos EC formulations

Benzoylecgonine in Urine by SAMHSA GC/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Trajan SGE GC Columns

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

DEVELOPMENT AND VALIDATION OF GC-FID METHOD FOR THE DETERMINATION OF ETHANOL RESIDUE IN MARJORAM OINTMENT

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Opiates in Urine by SAMHSA GC/MS

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

GC-APCI IMS of Diesel

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

Direct Exposure Probe Analysis on the Pegasus HT: An Application Compendium

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

Agilent G3212 GC-APCI Source

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Methyl 2-[[1-(5-fluoropentyl)indole-3-carbonyl]amino]-3,3- dimethyl-butanoate

Bath Salts and Cannabinoids Analyzed by GC-IR

Experiment DE: Part II Fisher Esterification and Identification of an Unknown Alcohol

COMPLEX HEROIN COMPARISON INVESTIGATION

3-Fluoromethcathinone Latest Revision: March 29, 2013

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Volatile organic compounds (VOCs):

Varian Galaxie Chromatography Data System for Preparative HPLC

Supporting Information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

2401 Gas (liquid) Chromatography

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Analysis of Fluorofentanyl Isomer Compounds by Gas-Chromatography Coupled with Solid Phase Infrared Detector IR_AN_047

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Chromatography. Gas Chromatography

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Chapter 31 Gas Chromatography. Carrier Gas System

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

U.S. EPA Method 8270 for multicomponent analyte determination

Chemistry Gas Chromatography: Separation of Volatile Organics

Activity in the FID Detection Port: A Big Problem if Underestimated

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

BUFOTENINE Latest Revision: August 16, 2005

Luminescence transitions. Fluorescence spectroscopy

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer

SPE AND GC MS INVESTIGATION OF ORGANIC CONTAMINANTS IN ATMOSPHERIC PRECIPITATION

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

1. GENERAL INFORMATION IUPAC

Highly Sensitive and Rugged GC/MS/MS Tool

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

ANALYTICAL REPORT. 25B-NBOH (C17H20BrNO3) 2-({[2-(4-bromo-2,5-dimethoxyphenyl)ethyl]amino}methyl)phenol RSUNJYKZRKIBNB-UHFFFAOYSA-N

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

637. Thiamethoxam. HPLC method

Introduction to Capillary GC

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

Chapter 27: Gas Chromatography

In recent weeks, there have been a number of reports

1-(2-METHOXYPHENYL)PIPERAZINE Latest revision: June 27, 2005

3) In CE separation is based on what two properties of the solutes? (3 pts)

Thermal Soil Desorber Instructions September 2006

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

Transcription:

JWH-018 and JWH-022 as Combustion Products of AM2201 The emergence of synthetic cannabinoids continues to prove challenging to the forensic scientist. As the initially popular compounds, such as JWH-018 (1-pentyl-3-(1-naphthoyl)indole, have become controlled, several other synthetic cannabinoids have appeared to replace them for recreational use [1]. This laboratory has seen a surge in cases containing AM2201 (1-(5-fluoropentyl)-3-(1-naphthoyl)indole). As can be seen in Figure 1, AM2201 differs from JWH-018 by the replacement of a hydrogen atom on the end of the alkyl chain with a fluorine atom. In analyzing case specimens which contain AM2201, small amounts of JWH-018 and JWH-022 (1-(4-pentenyl)-3-(1- naphthoyl)indole) have been detected, interestingly, only in samples recovered from smoking devices or smoked cigar/ cigarette butts. Due to the similarities in their structures (JWH- 022 differs from JWH-018 by a double bond at the end of the alkyl chain), it was theorized that the JWH-018 and JWH-022 in the burnt residues may have occurred from the combustion of the plant material upon which the AM2201 was deposited. Experimental Standards and Reagents A plant material sample was confirmed to contain AM2201 using GC/MS. A standard of JWH-018 was obtained from Cayman Chemical (Ann Arbor, MI) and ACS grade methanol (Fisher Scientific, Fair Lawn, NJ) was used as a solvent. Kathryn M. Donohue* and Robert R. Steiner Virginia Department of Forensic Science Controlled Substances Laboratory 700 North 5 th Street Richmond, VA 23219 [email: kathryn.donohue@dfs.virginia.gov] ABSTRACT: The analysis of charred samples of synthetic cannabinoids led to the discovery of JWH-018 and JWH-022 as combustion products of AM-2201. The steps needed to separate these compounds for identification using GC/MS and AccuTOF- DART are discussed. KEYWORDS: chemistry. synthetic cannabinoids, AM2201, JWH-018, JWH-022, combustion, GC/MS, AccuTOF-DART, forensic Methods and Instrumentation In order to test the theory of JWH-018 and JWH-022 arising as combustion products of AM2201, a pipe was fashioned from a section of a glass (5 ml) pipette, with copper wool inserted in one end. Plant material that contained AM2201 was packed into the end, above the wool. A vacuum line was used to draw the combustion products through the pipe as a match was used to ignite the plant material. After cooling, the pipe was rinsed thoroughly with methanol. An additional sample of the un-burnt plant material was extracted with methanol for comparison. An Ion Sense (Saugus, MA) Direct Analysis in Real Time (DART ) ionization source coupled with a JEOL, Inc. (Peabody, MA) Accurate Time of Flight Mass Spectrometer (AccuTOF ) was used to collect data in the 65-600 Da range. The AccuTOF orifice 1 voltage was set to 30V. The DART gas, Helium (He), was heated to 275 o C with a flow rate of 2.5 L/min. The methanol extracts of both the burnt and un-burnt samples were introduced into the ionization source with a glass melting point tube. More detailed information about DART can be found in articles by Cody, et al [2,3] and Steiner [4]. An Agilent (Little Falls, DE) dual column 7890 GC using an Agilent HP-5MS column (0.25 mm ID x 15 m x 0.25 µm film) and coupled with a 5975 mass spectrometer was used to collect (A) (C) Figure 1 - Structures of (A) 1-(5-fluoropentyl)-3-(1-naphthoyl)indole (AM2201), Formula: C 24 H 22 FNO, Molecular weight: 359.4 Da; 1-pentyl-3-(1-naphthoyl)indole (JWH-018), Formula: C 24 H 23 NO, Molecular weight: 341.5 Da; and (C) 1-(4-pentenyl)-3-(1- naphthoyl)indole (JWH-022), Formula: C 24 H 21 NO, Molecular weight: 339.4 Da. 52 Microgram Journal, Volume 9, Number 2

(A) Figure 2 - Un-burnt plant material extract: (A) 30V AccuTOF- DART TM spectrum showing [M+H] + of AM2201; enlarged section of spectrum showing no peaks for JWH-018 or JWH-022. (A) Figure 3 - Methanol extract of pipe after burning plant material: (A) 30V AccuTOF-DARTTM spectrum; enlarged section of spectrum showing presence of peaks for JWH-018 and JWH-022. spectra in the 14-600 m/z range. An Agilent HP-1 column (0.25 mm ID x 15 m x 0.25 µm film) was attached to a flame ionization detector (FID). The columns are joined in one split/ splitless injection port using a two-hole ferrule. This allows data to be simultaneously collected from the mass spectrometer and the FID signal. Using a split ratio of 60:1, the temperature program for the GC ran from 200-300 o C at a ramp rate of 30 o C/min, He flow was 1.8 ml/min, the injection port was set at 290 o C, the mass spectrometer transfer line was set at 300 o C Figure 4 - Total ion chromatogram from HP-5MS column showing AM2201 at 4.61 min and co-eluted peak of interest at 4.12 min. and the FID temperature was set at 290 o C. For further separation and identification, a 30 meter HP-1MS column (0.25 mm ID x 0.25 µm film) was used under the same conditions in a different 7890/5975 GC/MS system. Using an Agilent HP-35 (0.25 mm ID x 15 m x 0.25 µm) column installed in an Agilent 6890 GC, a temperature program was run from 225-300 o C at a ramp rate of 30 o C/min, He flow was 1.8 ml/min, the injection port was set at 270 o C and the detector was set at 280 o C. An Agilent HP-1column (0.25 mm ID x 15 m x 0.25 µm film) was also used with the Agilent 6890 GC under the same conditions. Results and Discussion The AccuTOF-DART data of the un-burnt plant material extract (Figure 2) shows a large peak for AM2201 ([M+H] + 360.1794 Da) and nothing at the expected masses for JWH-018 ([M+H] + calc. 342.1858 Da) and JWH-022 ([M+H] + calc. 340.1701 Da) within the 5 mda acceptance criteria. Figure 3 displays the resultant spectrum obtained from the methanol extract of the smoking device. JWH-018 is seen well within the acceptance range (342.1878 Da). The JWH-022 peak is slightly out of range but, as these are relatively small peaks, in a mixture spectrum, there is likely noise or other interference in the mass assignment of this peak. Figure 4 shows the GC/MS data for the burnt plant material, with the peak at 4.61 min being AM2201 and the peak at 4.12 min showing the co-elution of JWH-018 and JWH-022 (Figure 5). Some distinction can be seen on the FID HP-1 column between these two compounds in the peak at 4.32 min (Figure 6). It is of interest to note that very small amounts of JWH-018 and JWH-022 also appear to form as combustion products of AM2201 in the injection port of the GC. Recalling that the AccuTOF-DART analysis of the unburned plant material Microgram Journal, Volume 9, Number 2 53

(A) (Figure 2) did not show evidence of either of these products, the GC/MS data of the un-burnt material (Figures 7 and 8) shows their presence, with JWH-022 forming at a greater rate than JWH-018. The temperature to which the AM2201 is exposed in the AccuTOF-DART (275 o C) is not as high as the temperature in the injection port of the GC (290 o C), which in turn is less than the burning temperature in an actual flame. Given the relative ratio of AM2201 to the combustion products formed and, as the conversion in the injection port is not very aggressive, it is likely that the peak at 4.12 min, in unburned samples of AM2201, would not be seen under normal dilution. However, since the amount of JWH-018 in the burnt sample is roughly ten times greater, it is very probable that the JWH-018 would be in sufficient quantity for identification. 4.73 339 339 341 341 2.20 2.55 2.91 1.46 4.12 Figure 5 - (A) Co-eluted mass spectrum of JWH-018 and JWH-022; reconstructed ion chromatogram showing coelution on the HP-5MS column. Figure 7 - Total ion chromatogram and (inset) reconstructed ion chromatogram of methanol extract of un-burnt plant material showing formation of JWH-018 and JWH-022 from heat of injection port. Note relative abundance of peak at 4.12 min to AM2201 peak at 4.73 min. Figure 6 - Enlarged portion of chromatogram from HP-1 (FID) column showing slight separation of peaks of interest (GC/MS conditions). Figure 8 - Spectrum of peak at 4.12 min in Figure 7. 54 Microgram Journal, Volume 9, Number 2

Figure 9 - JWH-018 standard run under GC-only conditions (FID) on HP-35 column. Figure 11 - JWH-018 standard run under GC-only conditions (FID) on HP-1 column. Figure 10 - Burnt plant material extract with GC-only conditions (FID) on HP-35 column. As co-elution between the two compounds does occur under the normal operating conditions of this laboratory; the identification of JWH-018 in burned samples requires additional measures. Thin Layer Chromatography does not provide significant chromatographic separation for synthetic cannabinoids [5], however, gas chromatography using an Agilent HP-35 column provided nearly baseline separation between JWH-018 and JWH-022 (Figures 9-10). While the separation is not as prominent on the GC using the HP-1 Figure 12 - Burnt plant material extract with GC-only conditions (FID) on HP-1 column. column, it did give enough separation to provide comparison to the JWH-018 standard (Figures 11 and 12). It should be noted that Figures 10 and 12 represent actual casework data of a cigarette butt containing charred AM2201. The additional peaks present are not identified in the scope of this paper. In order to obtain a clean mass spectrum of JWH-018 for structural confirmation, a 30 meter HP-1MS column afforded enough separation, with ion reconstruction, to provide a good spectrum (Figure 13). Microgram Journal, Volume 9, Number 2 55

JWH-022 JWH-018 JWH-022 JWH-018 Figure 13 - Reconstructed ion chromatogram and subtracted spectra of JWH-022 and JWH-018 run on GC/MS with 30m HP-1MS column. References 1. Wiley JL, Marusich JA, Huffman JW, Balster RL, Thomas BF. (2011). Hijacking of basic research: The case of synthetic cannabinoids. RTI Press publication No. OP-0007-1111. Research Triangle Park, NC: RTI Press. http://www.rti.org/rtipress. Retrieved March 13, 2012. 2. Cody RB, Laramee JA, Nilles JM, Durst HD. Direct Analysis in Real Time (DART ) mass spectrometry. JEOL News 2005;40(1):8-12. 3. Cody RB, Laramée JA, Durst HD. Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal. Chem. 2005;77(8):2297-2302. 4. Steiner RR, Larson RL. Validation of the Direct Analysis in Real Time source for use in forensic drug screening. J Forensic Sci. 2009; 54(3):617-622. 5. http://www.atk.gov.tr/pdf/huestissyntheticcannabinoids.pdf. Retrieved March 12, 2012. 56 Microgram Journal, Volume 9, Number 2