Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form

Similar documents
7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

Chapter 4: Verification of compendial methods

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Impact factor: 3.958/ICV: 4.10 ISSN:

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Volume 6, Issue 2, January February 2011; Article-015

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Development and Validation of a HPLC Method for Chlorphenamine Maleate Related Substances in Multicomponents Syrups and Tablets

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Fast methods for the determination of ibuprofen in drug products

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

J Pharm Sci Bioscientific Res (4): ISSN NO

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

METHOD DEVELOPMENT AND VALIDATION OF RALTEGRAVIR POTASSIUM AND RILPIVIRINE HCL BY HPLC AND HPTLC METHODS

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Available online Research Article

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Praveen kumar.m 1 *, Sreeramulu.J 2. *Corres.author: Mobile no: India.

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Validated spectrophotometric determination of Fenofibrate in formulation

INDICATING LIQUID CHROMATOGRAPHIC METHOD FOR QUANTIFICATION OF CIPROFLOXACIN HCL, ITS RELEATED SUBSTANCE AND TINIDAZOLE IN TABLET DOSAGE FORM

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

International Journal of Pharmaceutical Research & Analysis

Appendix II- Bioanalytical Method Development and Validation

Journal of Chemical and Pharmaceutical Research

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Pelagia Research Library

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

Shabir: Simultaneous HPLC Determination of Preservatives in Gels

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

HPLC Method Development and Validation for the estimation of Esomeprazole in Bulk and Pharmaceutical Dosage Form

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Impact factor: 3.958/ICV: 4.10 ISSN:

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Rapid and simultaneous determination of paracetamol, ibuprofen and related impurity of ibuprofen by UPLC/DAD

Journal of Drug Delivery and Therapeutics

New Simple UV Spectrophotometric Method for Determination of Mirtazapine in Bulk and pharmaceutical dosage forms

Journal of Chemical and Pharmaceutical Research, 2017, 9(10): Research Article

Scholars Research Library

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

Isocraticc Reverse Phase HPLC Method-Determination and Validation of Cilostazol

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Development And Validation Of Stability Indicating RP-HPLC Method For Estimation Of Ledipasvir And Sofosbuvir

Department of Chemistry, JNTUACE, Kalikiri

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF IVABRADINE HCL IN BULK AND FORMULATION

Pelagia Research Library

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

LC Determination of Deferasirox in Pharmaceutical Formulation

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

Quantitation of Sodium Bisulfite in Pharmaceutical Formulation by RP-HPLC

Journal of Chemical and Pharmaceutical Research

Pelagia Research Library

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Relative Response Factor for Lamivudine and Zidovudine Related substances by RP-HPLC with DAD detection

A Stability Indicating UPLC Method for Candesartan in Bulk Drug Samples

Research Article Available online at

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

In the present analytical project, an attempt has been made to develop a simple, economical and reliable liquid

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

STABILITY INDICATING RP-HPLC METHOD FOR DETERMINATION OF EPROSARTAN IN PURE AND PHARMACEUTICAL FORMULATION

Research Article. *Corresponding author S.Ushasri

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

ANALYTICAL METHOD PROCEDURES

Transcription:

Research Paper Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form G. A. SHABIR School of Life Sciences, Oxford Brookes University, Oxford, Headington Campus, OX3 0BP, United Kingdom Shabir: HPLC Method of Methamphetamine and Propranolol A new isocratic reversed-phase HPLC method with diode-array UV detection was developed and validated for the determination of methamphetamine and propranolol in tablet dosage forms. Chromatography was carried out on an XTerra RP18 (150 4.6 mm, 5 µm) column using 50 mm pyrrolidine (ph 11.5) acetonitrile (50:50, v/v) as mobile phase at a flow rate of 1 ml/min. Spectrophotometric detection was performed at a wavelength of 214 nm. The linearity was established over the concentration range of 0.075-0.60 mg/ml for both drugs. The correlation coefficients (r 2 ) were 0.9998 in each case. The relative standard deviation values for intermediate precision studies were <1%. Statistical analysis of the data showed that the method was precise, accurate, reproducible and selective for the analysis of methamphetamine and propranolol drugs. The method was successfully employed for the determination of propranolol and methamphetamine in commercially available tablet dosage form. Key words: Methamphetamine, propranolol, reversed-phase high-performance liquid chromatography, tablets, test method validation Methamphetamine is a popular recreational drug that has also had some historical use as a therapeutic agent. It increases alertness and energy, and in high doses, can induce mental/emotional, enhance self-esteem, and increase sexual pleasure [1,2]. It has a history as a periodically popular drug of abuse, which at the time of writing is undergoing resurgence in popularity [3]. Methamphetamine (MET, fig. 1) is the common name for N,α-dimethylphenethylamine, also referred to as desoxyephedrine, methylamphetamine, phenylisopropylmethylamine, and a variety of other similar systematic names. MET is an amphetamine derivative and belongs to the class of amphetamines. MET is a prototypical basic drug (pk a 9.9), and is readily extracted from biological material into organic solvents at alkaline ph. generic forms in tablet, oral solutions and syrups formulations as propranolol hydrochloride. PRO is also used to lower blood pressure, abnormal heart rhythms, heart disease and certain types of tremor. Unfortunately, supply of MET drug has increased dramatically on the European illegal market [4,5], including Macedonia. Consequently, the analysis of MET has become of increased interest from a point of view of toxicology, occupational medicine and law enforcement. The literature presently describes only one analytical method for analysis of MET and its metabolites in plasma using high-performance liquid chromatography (HPLC) with C6 column [6]. Literature survey revealed that the reversed-phase liquid chromatography method of analysis has Propranolol is a beta-adrenoceptor blocking drug (beta-blocker) mainly used in the treatment of angina and hypertension. It is the only drug proven effective for the prophylaxis of migraines in children. Propranolol (PRO, fig. 1) is available in HN O OH N H Address for correspondence E-mail: drshabirg@gmail.com Methamphetamine Propranolol Fig. 1: Chemical structures of component studied in this work 430 Indian Journal of Pharmaceutical Sciences July - August 2011

not been explored for MET and PRO in single chromatographic run until to date. Therefore it was felt necessary to develop a HPLC method for determination of MET and PRO. In view of this, the present study describes the development of a new, simple, rapid and robust HPLC method with diode-array UV absorbance (DAD UV) detection for the determination of MET and PRO drug substance and from tablet formulations. Finally, the developed method was validated to assess the validity of research data means determining whether the method used during the study can be trusted to provide a genuine, account of the intervention being evaluated. As a best practice [7,8] in the subsequent investigation, the new HPLC/DAD UV assay method was validated according to criteria described in the literature [9,10]. MATERIALS AND METHODS All chemicals and solvents were of analytical reagent grades. Acetonitrile was obtained from BDH (UK). Methamphetamine (N-methyl-1-phenyl-propan- 2-amine), propranolol (RS)-1-(isopropylamino)- 3-(1-naphthyloxy)propan-2-ol) and pyrrolidine (tetrahydropyrrole) were purchased from Sigma- Aldrich (UK). Ultra-purified (deionised) water was prepared in-house using a Milli-Q water system (Millipore, UK). Methamphetamine and propranolol tablets were obtained from local pharmacy (Oxford, UK). A Knauer HPLC system (Germany) equipped with a model 1000 LC pump, an online degasser, model 3950 autosampler, and model 2600 photodiode-array detector was used. The data were acquired via Knauer ClarityChrom Workstation data acquisition software. XTerra RP 18 (150 4.6 mm, 5 mm particle size) column (Waters, UK) was used. The mobile phase consisted of a mixture of 50 mm pyrrolidine (ph 11.5) acetonitrile (50:50, v/v) was used, at a flow rate of 1 ml/min. The injection volume was 10 ml and the UV detection wavelength was set at 214 nm. Reversed-phase HPLC analysis was performed isocratically at 30. Standard preparation: Stock solutions of MET and PRO were prepared in mobile phase at concentrations of 1 mg/ml (S1). The solutions were stored at room temperature (22±1 ) until analysis. Series of standards for each of the substance was prepared by progressive dilution of the stock solution for calibration study. Fifteen millilitre aliquot of S1 was transferred to another 50 ml volumetric flask and diluted in mobile phase yielding a final concentration of 0.3 mg/ml. Sample preparation: The mean weight of finally powdered PRO tablets containing 80 mg of PRO was accurately transferred into 50 ml volumetric flask and about 30 ml of mobile phase was added; the mixture was extracted in the ultrasonic bath for 10 min at room temperature and diluted with mobile phase to the mark. The supernatant liquid was filtered through 0.22 µm filter. Two millilitre of this solution was transferred to the 10 ml volumetric flask and diluted with mobile phase to the mark and 10 µl was injected into the chromatographic system. Specificity study: The ability of an analytical method to unequivocally assess the analyte in the presence of other component in the formulation (impurities, degradations, excipients) can be demonstrated by evaluating specificity. The specificity of the method was determined by injecting placebo solution having the same concentration as that of the tablet solution. Forced degradation studies of the tablet sample were also performed. Tablet samples were prepared and degraded under stress conditions like acidic hydrolysis, basic hydrolysis, oxidative degradation, photo degradation and thermal degradation for HPLC method. For acid, base and oxidative degradation, samples were individually placed into three volumetric flasks and then 0.1M HCl, 0.1M NaOH and 3% H 2 O 2 were added separately into the flasks. All the three flasks were then heated in a water bath at 80 for 4 h. Acid and base treated sample were neutralised and all the three samples were then diluted to a concentration of 0.3 mg/ml with the mobile phase. For thermal degradation sample was exposed to heat at 60 for 4 h and for photo degradation, the drug sample was exposed under a UV lamp for 24 h. The samples were withdrawn and analysed using HPLC/DAD UV. RESULTS AND DISCUSSION The procedure for the simultaneous analysis of MET and PRO using isocratic HPLC/DAD UV method is reported. The mobile phase was chosen after several trials with methanol, acetonitrile, water and buffer July - August 2011 Indian Journal of Pharmaceutical Sciences 431

solutions in various compositions and at different ph values. The best separation was obtained using the mobile phase consisted of a mixture of 50 mm pyrrolidine (ph 11.5) and acetonitrile (ACN) in ratio of (50:50, v/v). In reversed-phase HPLC, the ph of the eluent can significantly influence the separation of components. Buffers are required when the sample contains ionic or ionisable analytes. Without a buffer, poor peak shape and variable retention may result. The organic buffer pyrrolidine (pk a 11.1) was chosen for optimum column life time as phosphate buffers accelerate the dissolution of silica at ph>7. Flow rates between 0.5 and 1.5 ml/min were studied. A flow rate of 1 ml/min gave an optimal signal to noise ratio with excellent separation time. The diode-array UV absorbance detector was set at 200 to 400 nm and MET and PRO drug components were extracted at maximum absorption at 214 nm and this optimal wavelength was chosen for the assay method. The separation of basic compounds requires special reversed-phase (RP) chromatographic sorbents. Retention, selectivity and peak symmetry of basic compounds are strongly been influenced by the silica matrix. Strongly distorted peaks of the basic compounds are often been observed when unsuitable RP sorbents are used, due to the interaction of the basic compounds with un-reacted silica gel (SiOH) groups on the silica matrix [11]. XTerra RP 18 is a spherical porous silica carrier, in which the starting silica material optimised in order to prevent any secondary interactions with basic compounds. The usage of this type of column allows separation of basic compounds such as MET and PRO with dissociation constants values (pk a ) of 9.9 and 9, respectively without the need of ion pair reagents. Using XTerra RP 18, the retention times for MET and PRO were found to be 2.30 and 2.86 min, respectively. Total time of analysis was <4 min. Using these optimised conditions, typical chromatogram obtained is illustrated in fig. 2a. Robustness verification studies were also performed in the method development phase. The robustness of the analytical method is defined as the measure of its capacity to remain unaffected by small but deliberate variations in the method parameters and provides an indication of its reliability during normal usage. One way to gauge robustness is to examine some relevant factors, which might influence the reliability of the developed method. Selected factors, namely the mobile phase composition (±2 ml), flow rate a b Fig. 2: HPLC chromatogram obtained from sample: (a) MET (t R =2.30 min) and PRO (t R =2.86 min) and (b) placebo (±0.1 unit), temperature (±2 ), wavelength (±5 nm) and column from different lots were investigated. In all cases, good separations of both drug components were always achieved, indicating that the analytical method remained selective and robust under the optimised conditions. System suitability testing verifies that the HPLC system is working as expected. It is based on the concept that the equipment, electronics, analytical operations and samples to be analysed constitute an integral system. System suitability was evaluated by injecting a solution of MET and PRO drugs at 100% test concentration (0.3 mg/ml) in six replicates at the beginning of the validation run. System suitability parameters calculated from the chromatogram (fig. 2a), such as peak capacity factor (K ), tailing factor (T), resolution factor (R s ), theoretical plate numbers (N, column efficiency) and percent relative standard deviation (RSD) of peak areas are given in Table 1. The obtained values of these parameters (1<k <10, T 2, R S >2, N>2000) show that the proposed chromatographic conditions are suitable for separation of the analysed drug components. The 432 Indian Journal of Pharmaceutical Sciences July - August 2011

values for the injection repeatability (RSD<2%, n=6) show that the system is precise. Linearity test solutions were prepared by diluting stock solution (1 mg/ml) at six concentration levels from 25 to 200% of analytes concentration (0.075-0.6 mg/ml) for both drugs. The solution was injected in triplicate and curves were obtained by plotting the peak area against concentration of the drugs. Linear calibration curves were generated using leastsquares linear regression analysis. The mean of two different calibration graphs yielded the following equations: y=203.17x-0.2552 (r 2 =0.9998) for MET and y=133.99x+5.0261 (r 2 =0.9999) for PRO (Table 2). An excellent correlation exists between the peak areas and concentration of MET and PRO drugs. The precision of the test method was demonstrated by intra-day and inter-day variation studies. The intra-day (repeatability) studies were carried out by injecting six repeated injections of standard solution of 0.3 mg/ ml on the same day, by one analyst under the same experimental conditions. The RSD values for peak areas were found to be 0.27% and 0.19%, respectively (Table 2). The intermediate precision (inter-day variation) was studied over three consecutive days at three different concentration levels 0.15, 0.3 and 0.45 mg/ml for MET and PRO that cover the assay TABLE 1: SYSTEM SUITABILITY TEST PARAMETER Parameter MET PRO Retention time (min) 2.30 2.86 Retention factor (k) 1.14 2.56 Resolution (R s ) - 5.23 Tailing factor (T) 1.13 1.14 Plate number (N) 4362 5026 Injection repeatability* 0.36 0.29 *Six replicate injections, RSD (%) TABLE 2: METHOD VALIDATION RESULTS Validation parameter Drug substances MET PRO Linearity (0.075-0.6 mg/ml) Regression equations (r 2 ) y=203.17x - 0.2552 (0.9998) y=133.99x + 5.0261 (0.9999) Intra-day precision (RSD %) 0.3 mg/ml (n=6) 0.27 0.19 Accuracy/recovery (%) 0.15 mg/ml (50) a 99.84±0.22 b 99.91±0.34 0.30 mg/ml (100) 99.98±0.11 99.82±0.28 0.45 mg/ml (150) 99.62±0.17 101.07±0.21 LOD µg/ml, (s/n) c 0.85, (s/n=3.2) 0.95, (s/n=3.3) LOQ µg/ml, (s/n) 2, (s/n=10.3) 2.5, (s/n=10.2) a Applied concentration % of target, b The coefficient of variation (CV %), n=3, c Signal-to-noise ratio range (80-120%). Three replicate injections were injected for each solution. The mean and RSD across the system were calculated from the individual peak area % purity mean values at the 50, 100 and 150% testing amounts. The precision was calculated as: %RSD=(SD/Mean) 100. The RSD values for peak areas obtained by both analysts were 1% (fig. 3), and met the intermediate precision criteria (RSD<2%) which illustrated the good precision of this analytical method. The accuracy of an analytical method is determined by how close the test results obtained by that method come to the true value. It can be determined by application of the analytical procedure to an analyte of known purity (for the drug substance) or by recovery studies, where a known amount of standard is spiked in the placebo (for drug product). In the present study, a number of different solutions were prepared with a known added amount of 50, 100 and 150% for MET and PRO drug components and injected in triplicate (n=3). Percent recoveries of response factor (area and concentration) were calculated ranged from 99.62-101.07% (Table 2) which indicated the accuracy of the method was accurate within the desired range. Injections of the placebo were performed to demonstrate the absence of interference with the elution of the MET and PRO drugs. These results (fig. 2b) demonstrate that there was no interference from the other compounds and, therefore, confirm the specificity of the method. For the further evaluation of the selectivity of the HPLC method, the forcibly Fig. 3: Comparison of intermediate precision evaluated over three days at three different concentration levels of drug analytes (n=3) Day 1, Day 2, Day 3 July - August 2011 Indian Journal of Pharmaceutical Sciences 433

TABLE 3: RESULTS OF THE STRESS CONDITIONS EXPERIMENTS Stress conditions t R (min) Assay (%) RSD (%) Reference (fresh 2.30, 2.86* 99.94, 99.98 0.22, 0.14 solution) Acidic (0.1M HCl 2.29, 2.85 98.97, 99.17 0.48, 0.32 at 80 for 4 h) Basic (0.1M NaOH 2.30, 2.86 99.82, 99.67 0.26, 0.56 at 80 for 4 h) Oxidative (3% H 2 O 2 2.31, 2.87 98.97, 98.77 1.22, 1.34 at 80 for 4 h) Heat (60 for 4 h) 2.27, 2.83 99.86, 99.89 0.78, 0.92 Light (UV light for 24 h) 2.30, 2.85 99.62, 99.14 0.25, 0.17 *Data for methamphetamine and propranolol, respectively degraded tablet sample solutions prepared by subjecting the tablet samples to such stress conditions as acid, base, heat, light and oxidative agent were determined under the proposed optimised HPLC conditions. A summary data of the stress results is shown in Table 3, which showed no changes in retention times of drug components and no degradation peaks were observed. This was further confirmed by peak purity analysis on a HPLC/DAD UV and, therefore, confirms the specificity of the method. The limit of detection (LOD) and limit of quantitation (LOQ) were determined by the calibration plot method. A specific calibration plot was constructed using samples containing amounts of analytes in the range of LOD and LOQ. The values of LOD were 0.85 µg/ml (s/n=3.2) and 0.95 µg/ml (s/n=3.3) and LOQ were 2 µg/ml (s/n=10.3) and 2.5 µg/ml (s/n=10.2) for MET and PRO, respectively. LOD and LOQ were calculated by using the equations: LOD=Cd Syx/b and LOQ=Cq Syx/b where Cd and Cq are the coefficients for LOD and LOQ, Syx is the residual variance of the regression, and b is the slope. Calculations were performed by using values of Cd and Cq of 3.3 and 10. Precision at the limits of quantitation and detection was checked by analysis of six test solutions prepared at three levels. The RSD values for peak area were <5% for LOD and <2% for LOQ solutions (Table 2), which indicates the sensitivity of the method is adequate. The stability of analyte stock solutions with mobile phase as solvent, stored at room temperature, was studied for 48 h. No analyte (MET or PRO) degradation was detected during this time period (<2%). TABLE 4: RECOVERY STUDIES OF METHAMPHETAMINE AND PROPRANOLOL CONTENT IN TABLETS Comp. (lot no.) Added (mg) Found (mg) n Recovery (%) RSD 0(%) Methamphetamine 1 5 5.03 5 100.06-101.02 1.07 2 5 4.92 5 98.40-100.04 1.64 3 5 4.98 5 99.60-100.29 1.03 Propranolol 98.40-101.02 1 80 78.93 5 98.66-101.07 1.13 2 80 79.54 5 99.42-102.04 0.86 3 80 79.48 5 99.35-102.11 1.24 To demonstrate the applicability of the present method, commercially available three batches of tablets containing 5 mg MET and 80 mg PRO were analysed. Assay results for three samples of tablets expressed as the percentage of the label claim, were found 98.40-101.02 for MET and 98.66 to 102.11% for PRO. Results showed (Table 4) that the content of MET and PRO in tablet formulation were to the counter requirements (90-110% of the label claim). The above results demonstrated that the developed method achieved rapid and accurate determination of compound studied and can be used for the simultaneous determination of MET and PRO in drug substances and pharmaceutical formulations. A new isocratic RP-HPLC/DAD UV method has been developed for the determination of MET and PRO. Low cost, environment friendly, faster speed analysis, and satisfactory precision and accuracy are the main features of this method. The method was critically validated and statistical analysis of generated high quality data proves that the method is sensitive, specific and robust. The method is stabilityindicating and can be conveniently applied for the testing of studied components raw materials, in tablet formulations and batch release by industry. ACKNOWELDGEMENTS I thank Dr. Tony Bradshaw (School of Life Sciences, Oxford Brookes University) for his support in buying materials for research work. REFERENCES 1. Logan BK. Methamphetamine - Effects on human performance and behaviour. Forensic Sci Rev 2002;14:133-51. 2. Mack AH, Frances RJ, Miller SI. Clinical textbook of addictive disorders. 3rd ed. New York: The Guilford Press; 2005. 3. Anglin MD, Burke C, Perrochet B, Stamper E, Dawud NS. History of 434 Indian Journal of Pharmaceutical Sciences July - August 2011

the methamphetamine problem. J Psychoact Drugs 2000;32:37-43. 4. Hague. European Union situation report on drug production and drug trafficking. EUROPOL, 2000-01, 2001. 5. Pelegrini M, Rosati F, Pacifici R, Zuccaro P, Romalo FS, Lopez A. Rapid screening method for determination of ecstasy and amphetamines in urine samples using gas chromatography chemical ionization mass spectrometry. J Chromatogr B 2002;769:243-51. 6. Li NY, Li Y, Sellers EM. An improved HPLC method for analysis of methamphetamine and its metabolites in plasma. Eur J Drug Metab Pharmacokinet 1997;22:427-32. 7. Shabir GA, Lough WJ, Shafique AA, Bradshaw TK. Evaluation and application of best practice in analytical method validation. J Liq Chromatogr Relat Technol 2007;30:311-33. 8. Shabir GA. HPLC method development and validation for pharmaceutical analysis. Pharm Technol Eur 2004;16:37-49. 9. ICH Q2 (R1), International Conference on Harmonization, Validation of Analytical Procedures: Text and Methodology, Geneva, Nov. 2005. 10. USP-33. United States Pharmacopeia, general Chapter: 1225, validation of compendia procedures, Rockville, USA: United States Pharmacopieal Convention; 2010. 11. Skoog DA, Holler JF, Nieman TA. Principles of instrumental analysis. 5 th ed. Orlando: Harcourt Brace and Co. Press; 1998. p. 739. Accepted 8 August 2011 Revised 1 August 2011 Received 31 May 2010 Indian J. Pharm. Sci., 2011, 73 (4): 430-435 July - August 2011 Indian Journal of Pharmaceutical Sciences 435