Cooler-Bypass Thermostat Valve, Size 10

Similar documents
Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

K 080/12 F 10 K 3-2X/.. Features

Cartridge Valves Technical Information. Quick reference

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

Safety valve with unit approval type MV..X.., SV..X..

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Flow rates to 485 l/min

2-way proportional throttle valve for block installation

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Flow rates to 485 l/min

Flow rates to 485 l/min

High Pressure fi lters

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

387 Low & Medium Pressure filters

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

Flow rates to 590 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Flow rates to 475 l/min

Flow rates to 750 l/min

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

Flow rates to 750 l/min

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

331 Low & Medium Pressure filters

INTERNATIONAL STANDARD

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Polígono Indutrial O Rebullón s/n Mos - España -

29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V *

External gear pump Type G3, Series 3X

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

VOLUMEC. Valve Position Indicator 5

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

AIR BREATHER FILTERS. Temperature from -25 to +100 C

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

ELECTROHYDROSTATIC PUMP UNIT

Direct-operated 2/2-way compact solenoid valves Type EV210A

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Cartridge Valves Technical Information

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

VD1 CLC. Small Valves DIN-range with a higher k v -value

Polígono Indutrial O Rebullón s/n Mos - España -

Direct-operated 2/2-way solenoid valves Type EV210B

MPT Multifunction Multiport

STAINLESS STEEL FILTER

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

Differential indicators

FMM 050 uk :26 Pagina 5 (1,1) FMM 050

Solenoid valves 2/2-way direct-operated type EV210A

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Size A DIN EN

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy

mandata_us :43 Pagina 83 (1,1) FHB 82

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN

SERIES. Maximum pressure 8 bar

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

FMP :41 Pagina 5 (1,1) FMP

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n

MPF SERIES RETURN FILTER

HRN/HRN-C Series Hydraulic Vane Rotary Actuators

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies

Rotary modules.

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Hydraulic Fundamentals Hydraulics Definition Advent of Oil Hydraulics Pascal s Law Pressure

VISUAL LEVEL INDICATORS

Pumps type MP Motor pump combination for mounting into tanks for on/off service

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

EPIV electronic pressure-independent characterised control valve EPIV

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

SECTION 5 EDI Cartridge Valves

Transcription:

Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled, high performance screw-in cartridges with an M7x mounting thread. They are intended to be installed directly in coolers or line-mounting body. Depending on the temperature of the oil, they route the flow either straight to tank or through the cooler. When the oil is cold (< C resp. < C), the connection P T is open (bypass), which means that the flow is directed to tank with minimal headloss and the oil warms up rapidly. After the changeover temperature is reached (> C resp. > C), the integral thermostat element closes the connection Temperature-dependent bypass control Integral pressure-relief function Oil warms up rapidly (cold-start phase) Direct-mounted in coolers or manifold blocks Low headloss Choice of various pressure settings Very good reproducibility Extremely reliable Very stable operation All exposed parts with zinc-nickel plating Can be fitted in a line-mounting body P T. The valve now directs the oil flow through the cooler. With the integral pressure-relief function, the bypass thermostat cartridge also safeguards the cooler by protecting it from any pressure peaks that may result from excessive flow rates. The maximum pressure is determined by the model that is selected. The cartridges are predominantly used in coolers in mobile as well as industrial applications. All external parts of the cartridge are zinc-nickel plated to DIN 979 and are thus suitable for use in the harshest operating environments. Symbol T s P Technical data General characteristics Designation Design Mounting method Tightening torque Size Weight Mounting attitude Ambient temperature range Description, value, unit cooler-bypass thermostat valve temperature-controlled, integral relief function, choice of maximum pressure setting screw-in cartridge M7x Nm ± % size, cavity type DU. kg unrestricted - C + C Reference: -P-7-EN- Issue: 9. /

Hydraulic characteristics Maximum operating pressure Maximum flow rate Nominal pressure ranges Temperature for start of control action Flow direction Description, value, unit bar l/min bar bar (only C) bar (only C) bar (only C) bar (only C) bar (only C) (other pressures - consult BUCHER) Optional C or C see symbol Hydraulic fluid HL and HLP mineral oil to DIN ; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO : 999 - C + C mm /s (cst), recommended... mm /s (cst) class // Performance graphs measured with oil viscosity mm /s (cst) p = f (T) Pressure drop v. temperature [ C / bar ] P7.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P.ai T = C Q = l/min T [ C] T = < C Q [l/min] p = f (T) Pressure drop v. temperature [ C / bar ] P9.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P7.ai T = C Q = l/min T [ C] T = < C Q [l/min] / -P-7-EN-/9.

p = f (T) Pressure drop v. temperature [ C / bar ] 9 P7.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] 9 P7.ai T = C Q = l/min T [ C] T = < C Q [l/min] p = f (T) Pressure drop v. temperature [ C / bar ] P9.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P.ai T = C Q = l/min T [ C] T = < C Q [l/min] -P-7-EN-/9. /

p = f (T) Pressure drop v. temperature [ C / bar ] P.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P.ai T = 7 C Q = l/min T [ C] T = < C Q [l/min] p = f (T) Pressure drop v. temperature [ C / bar ] P.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P.ai Q = l/min T [ C] Q [l/min] p = f (T) Pressure drop v. temperature [ C / bar ] P.ai p = f (Q) Pressure drop v. flow rate [ C / bar ] P.ai T = 7 C Q = l/min T [ C] T = < C Q [l/min] IMPORTANT! Further pressure settings on request! / -P-7-EN-/9.

Dimensions & sectional view Installation information Ma = [Nm] ± % 7 Ø. IMPORTANT! When fitting the cartridges, use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. 9 M7x ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. T Seals P Item Description O-ring, x,9 HNBR7 7 Application examples Manifold block with integral cooler-bypass thermostat valve V V P WDTUVA... s T -P-7-EN-/9. /

Ordering code Ex. W D T UV A - - - _ - W = directional valve, cartridge construction D = direct acting T = temperature-actuated (thermostat element) UV = pressure-relief function is incorporated A... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER = response temperature of thermostat ~ C = response temperature of thermostat ~ C = pressure setting = p N = bar ( C and C) = pressure setting = p N = bar (only C) = pressure setting = p N = bar (only C) = pressure setting = p N = bar (only C) = pressure setting = p N = bar (only C) = pressure setting = p N = bar (only C) = for other pressure settings, please consult BUCHER = size J = HNBR seals (standard) (special seals - please consult BUCHER)... 9 = design stage (omit when ordering new units) 9 Related data sheets Reference (Old no.) Description -P- Cavity type DU -P-7 Line-mounting body, type GCUA (G / ) info.ch@bucherhydraulics.com www.bucherhydraulics.com by Bucher Hydraulics AG Frutigen, CH-7 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification:..-... / -P-7-EN-/9.