Determination of Limonene Oxidation Products Using SPME and GC MS

Similar documents
OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Determination of Volatile Substances Proof of Food Adulteration

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

AYOUB ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 85, NO. 6,

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

A Study of the Behavior of Maillard Reaction Products Analyzed by Solid-Phase Microextraction-Gas Chromatography-Mass Selective Detection

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

GC/MS Application Note

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

U.S. EPA Method 8270 for multicomponent analyte determination

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Application. Gas Chromatography February Introduction

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Gas Chromatography (GC)

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Chemical Analysis Problem

Headspace Solid Phase Microextraction/Gas Chromatography for Determination of Aldehydes

PAL SPME Arrow The Better SPME

PAL SPME Arrow The Better SPME

The Optimal Analytical Method of NDMA(N-Nitrodimethylamine) by Solid-Phase Microextraction Analysis (SPME)

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Application Note. Abstract. Authors. Introduction

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Ch24. Gas Chromatography (GC)

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

ChromTech options for PAL systems

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Selection of a Capillary

Chapter 27: Gas Chromatography

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Selection of a Capillary GC Column

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer

Analysis of BTEX in Natural Water with SPME

Volatile Organic Compounds in Every Day Food

Method for the determination of dimethyl sulfate

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Detection of Chemical Warfare Agents by Transportable GC/MS

Application Note 032

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

Separation and Characterization of Indian and Australian Sandalwood Oils

STANDARD OPERATING PROCEDURES

Solid-Phase Microextraction and Headspace Solid-Phase Microextraction for the Determination of Polychlorinated Biphenyls in Water Samples

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Environmental Chemistry

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography

Gas Chromatography. Introduction

Headspace Technology for GC and GC/MS: Features, benefits & applications

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Solid Phase Microextraction

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

Benzene Contamination in BabyFood and Beverages by New Generation of Static Headspace Autosampler coupled to Fast GC-TOFMS

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Transcription:

Determination of Limonene Oxidation Products Using SPME and GC MS Susan Sonchik Marine* and Jason Clemons Miami University Middletown, 4200 E. University Blvd., Middletown, OH 45005 Abstract Limonene is a common component found in consumer goods ranging from beverages to cleaning compounds. Limonene oxidation products, however, have a less desirable flavor and fragrance. Early detection of limonene oxide formation would aid quality control. A method is developed to determine the concentration of limonene oxide in essential oils and beverages using solid-phase microextraction (SPME). A headspace sampling technique is used to reduce or eliminate the presence of less volatile components. Several different SPME fibers are tested, varying in polymer thickness, polymer crosslinking and bonding, and polarity of the polymer. For each fiber tested, the sampling time is optimized for reproducible results. The 7-µm-thick bonded poly(dimethylsiloxane) fiber provides the best results. External standards are used for quantitation. Introduction Fragrance is most often associated with perfumes for personal adornment. But a large market involves the application of fragrances in consumer products ranging from household cleaning products to foods and beverages. Fragrant chemicals are added to enhance the enjoyment of the product or to mask unpleasant odors. Limonene (Figure 1A) is a common compound with a pleasant lemon scent. Unfortunately, it readily oxidizes to limonene oxides (Figure 1B and 1C) with an unpleasant smell and taste. Determination of oxide content in limonene or in the final product is important for determining product quality, the effects of storage time and temperature, and the effectiveness of packaging. Solid-phase microextraction (SPME) was used for the analysis of limonene oxide in essential oils, fruit juices, and juice beverages. Volatile components were sampled from the liquid through the headspace (HS) and into the fiber coating (1 4). This requires that an equilibrium be established for the components of the sample in the liquid phase and in the HS above the liquid, and a second equilibrium be established between the fiber coating and * Author to whom correspondence should be addressed: email mariness@muohio.edu. the HS. As the components in the HS are adsorbed by the SPME fiber they are replenished in the HS, which is caused by the equilibrium with the liquid. Thus the relative amounts of the components on the fiber reflect the concentrations in the liquid sample and not in the HS, provided sufficient time is allowed for all components to establish both equilibria. If shorter sampling times are used, volatile compounds can be accurately sampled while the presence of semivolatile components can be reduced or eliminated from the sample injected, thereby shortening the analysis time, simplifying sample preparation, and reducing the accumulation of nonvolatiles in the injection port. SPME sampling through HS has been compared with dynamic HS, static HS, direct liquid injection techniques (5 7), and to purge-and-trap analysis (8 10) in previous studies. Automated SPME has been compared with heated static HS analysis (11). The primary advantages of vapor-phase SPME sampling are solventfree sample preparation, separation of analyte from nonvolatile and less volatile components, shorter analysis time if larger and less volatile molecules are not injected, and avoiding gas chromatographic column degradation caused by injection of large volumes of water. Several factors must be considered when developing a quantitative analytical procedure using SPME. A variety of fibers are available differing in polarity, coating thickness, cross-linking, and phase bonding. The equilibrium between HS and fiber is different for any given analyte when different fiber coatings are used. Figure 1. Molecular structure and molar mass for limonene and limonene oxides. MW = molecular weight. Reproduction (photocopying) of editorial content of this journal is prohibited without publisher s permission. 31

For the best reproducibility, the sampling time should allow equilibrium to be established between the liquid sample, vapor phase, and fiber coating for the analytes of interest. For a given fiber coating, equilibrium is affected by temperature; agitation or stirring of the sample affects the rate at which equilibrium is established. It is possible to obtain excellent quantitative results with shorter sampling times than those necessary to establish equilibrium if all SPME conditions and the sampling time are held constant (12,13). Experimental Chemicals and reagents Research-grade (+)-limonene (stabilized with 0.03% tocopherol) (+)-limonene oxide (97%) were purchased from Acros Organics (Princeton, NJ). Baking-quality orange oil, lemon oil, Figure 2. Total ion chromatogram of lemon oil sampled with a 7-µm PDMS fiber for 1 min and analyzed under the split conditions listed Table II. The peak at 4.51 min is cis-limonene oxide. The peak at 4.58 min is translimonene oxide. (A) (B) and lime oil were purchased from Murray Brothers Old Time Store (Middletown, OH). Fresh lemon peel oil was obtained by steam distillation of lemon zest shaved from three fresh lemons. Pink lemonade, orange juice, and strawberry kiwi fruit drink were obtained from a local supermarket. Apparatus A gas chromatograph (GC) mass spectrometer (MS) (Hewlett- Packard G1800C GCD Series II system, Palo Alto, CA) was used and consisted of a GC with an electron ionization detector, an HP Kayak XA computer, and software provided by the manufacturer. SPME was performed using a manual holder, sampling stand, 0.75-mm-i.d. GC inlet liner, inlet guide, 100-µm nonbonded poly(dimethylsiloxane) (PDMS) fiber, 7-µm bonded polydimethylsiloxane (PDMS) fiber, and a 65-µm partially cross-linked carbowax divinylbenzene fiber from Supelco (Bellefonte, PA). A Fisher Scientific Stirring Hotplate (Pittsburgh, PA) with stir speeds from 100 1200 rpm was used to agitate the samples. Chromatographic conditions Chromatographic separation was achieved on a 30-m 0.25- mm i.d. fused-silica column coated with 0.25-µm thickness of HP-5 (cross-linked 5% phenyl 95% methyl siloxane). For percent concentrations of limonene oxide present, the split injection technique was used with a 130:1 split ratio. The column flow rate was 0.8 ml helium/min with a linear velocity of 33 cm/s. The oven temperature was maintained at 110 C for 6 min, then programmed at 20 C/min to 200 C and held for 1 min. For trace concentrations of limonene oxide, splitless injection was used. The column flow rate was 2.0 ml helium/min for the first minute while the injection port vent was closed; then it decreased to 0.8 ml/min with venting of the injection port. The oven temperature started at 40 C for 1 min, increased at 20 C/min to 100 C where it was held for 8 min, and finally increased at 50 C/min to 200 C with a final hold of 10 min. The fiber was desorbed in the injection port at 250 C for 1 min. Total ion chromatograms were plotted; (A) (B) Figure 3. Mass spectra of cis-limonene oxide in lemon oil sample (A) and from the reference library (B). Figure 4. Mass spectra of trans-limonene oxide in lemon oil sample (A) and from the reference library (B). 32

there was a 4-min solvent delay for the split injections (Figure 2) and an 8-min delay for the splitless injections. Mass-to-charge ratios of m/z 45 450 were scanned. (A flame ionization detector could be used instead of the MS.) Figure 2 is a total ion chromatogram of lemon oil. Figures 3 and 4 show the mass spectra of cis- and trans-limonene oxide from that lemon oil sample and from the reference library for identification. Standards For the analysis of essential oils, standards of limonene oxide were prepared in limonene. A stock solution was prepared by diluting 2.8 g limonene oxide with 18.5 g limonene; the exact masses were used to calculate the concentration. Dilutions were made with limonene to produce standards ranging from 1 13% by mass. Further dilutions of the 1% standard were made with limonene to produce part-per-million standards. Exactly 1.0 ml of each standard was placed in a 4-mL vial for analysis. For the analysis of beverages, an aqueous stock solution was made by spiking 100 µl limonene oxide into a 1.00-L solution. Dilutions were made with deionized water to produce standards ranging from 0.1 100 ppm by volume. Table I. Precision of Manual Injection* Area counts Area counts Trial cis-limonene oxide trans-limonene oxide 1 67816 43354 2 67600 43123 3 74114 43430 4 69876 44080 5 75306 47370 6 74435 44284 7 77949 46766 8 78333 46284 9 78262 44695 10 76579 44622 Mean 74027 44801 SD 4181 1501 RSD 5.6% 3.4% Method development using SPME Several different SPME fibers were tested, varying in coating thickness and polarity of the polymer. PDMS fibers are excellent for sampling nonpolar compounds and a wide range of other compounds. Previous studies have demonstrated the broad sampling ability of PDMS even for analytes that are structurally similar to other fiber coatings (11). Both the 100- and 7-µm-thick PDMS fibers effectively sampled the limonene oxide, even in the presence of a limonene matrix. Because the concentration of limonene oxide is much smaller than that of limonene as it undergoes oxidation, and because SPME can selectively sample components depending on the choice of fiber, a polar carbowax divinylbenzene fiber was tested to investigate whether the oxide group would increase the polarity sufficiently to preferentially sample limonene oxide over limonene. Unfortunately, the equilibrium constant for limonene oxide between the vapor phase and the polar polymer was so small that the low equilibrium concentration of the oxide on the fiber required splitless injection for adequate detection of the percent concentration samples. The part-per-million concentration samples would not be detected even with splitless injection. Thus the carbowax divinylbenzene fiber was not useful for this analysis. Parameters of sampling time, agitation, and temperature were examined for the fibers tested. Because the effect of each parameter was measured in terms of peak area counts, the precision of manual injection had to be measured before the effects of varying parameters could be determined. Murray Brothers Orange Oil (1.0 ml in a 4-mL amber vial) was sampled for 2.0 min with a 7- µm PDMS fiber at room temperature with 1200 rpm stirring. The data are shown in Table I. Ten replicate injections produced peak areas with 3 6% RSD for cis- and trans-limonene oxide. This is comparable to the precision achieved with manual liquid injections. Other studies have reported similar precision for quantitative SPME analyses (6); trace organic analyses have typically shown higher RSD values with SPME and with other traditional sampling techniques (14). This precision is sufficient to allow the effects of varying parameters to be measured. For each fiber tested, a sampling time study was conducted to choose the most appropriate exposure time for each fiber. A graph of area counts versus fiber exposure time tracks the increase of analyte on the fiber with prolonged exposure of the fiber to the vapor over the sample. When equilibrium is established the amount of analyte on the fiber will be constant and will result in a constant area count even with longer sampling time. Murray Brothers Orange Oil was used as the test sample for these studies. Exactly 1.0 ml of orange oil was pipetted into a 4-mL amber sample vial and stirred at 1200 rpm. The manual fiber holder was supported in a sampling stand to ensure uniform exposure. After the appropriate sampling time elapsed, the fiber was immediately retracted into the needle sheathe, withdrawn from the sample vial, and injected into the GC for analysis. For most analyses, the detector scanned m/z 45 200. However, to obtain a detectable response, a range of m/z 10 450 was scanned and splitless injec- * Measured using a 7-µm PDMS fiber and commercial orange oil. The room temperature sample was stirred at 1200 rpm. Fiber exposure time was 2.0 min. Split injection Sampling time (min) technique used a 50:1 split ratio. Standard deviation. Relative standard deviation. Figure 5. Effect of sampling time for the 7-µm PDMS fiber. 33

tion was used with the carbowax divinylbenzene fiber. Data are plotted in Figure 5 for the 7-µm PDMS fiber. Optimal sampling time would allow equilibrium to be established for the analyte of interest but minimize the time for adsorption of less volatile components. The appropriate sampling times were 4 min for the 7- µm PDMS fiber and > 10 min for the two thicker phases. The 100-µm PDMS fiber required a longer exposure time than the 7- µm fiber to achieve equilibrium, which was expected for diffusion in the thicker polymer and the resulting increased sample capacity. Even with a large injection split ratio, the sample of limonene oxide on the 100-µm PDMS fiber often overwhelmed Table II. GC Conditions for Analysis using a 7-µm PDMS Fiber Parameter Condition GC column 30-m 0.25-mm fused-silica coated with 0.25-µm thickness of HP-5 (cross-linked 5% phenyl 95% methyl siloxane) Fiber desorb time 1.0 min Injection port temperature 250 C Detector temperature 280 C Mass/charge ratios scanned m/z 45 200 Split injections Split ratio Column flow rate Oven temperature Solvent delay on detector Splitless injection Vent time Column flow rate Oven temperature Solvent delay on detector 130:1 (vent flow 103 ml/min) 0.8 ml/min helium, 33 cm/s 110 C for 6 min, 30 C/min to 200 C, held 1 min 4.0 min for elution of limonene 1.0 min 2.0 ml/min helium for 1 min, then 0.8 ml/min 40 C for 1 min, 20 C/min to 100 C for 8 min, 50 C/min to 200 C held for 10 min 8.0 min for elution of limonene Sampling time (min) Figure 6. Effect of stir rate on sampling time needed to reach equilibrium using constant area counts of trans-limonene oxide as an indicator of equilibrium. the MS detector. (Detection by the MS was delayed until the solvent eluted to avoid damaging the detector with the larger amounts of limonene.) The 100-µm thick fiber coating swelled somewhat when sampling the organic compounds, which shortened the fiber lifetime. The 7-µm PDMS fiber showed no swelling, had a longer useful life, and reached equilibrium with the sample faster than did the 100-µm PDMS fiber. The 7-µm PDMS fiber was chosen for sample analysis. Analytical conditions are listed in Table II. Agitation of the sample is a factor to consider when developing an SPME method. The 7-µm PDMS fiber and Murray Brothers Orange Oil were used with sampling times varying from 30 s to 6 min. The maximum stir rate possible was 1200 rpm; rates of approximately 850, 1100, and 1200 rpm were studied. Area counts of trans-limonene oxide versus sampling time are shown in Figure 6. Similar results were obtained for cis-limonene oxide. Area counts became constant starting with a sampling time of 4 min with stir rates of 850 1200 rpm. The stir rate seemed to affect the amount of sample obtained more than the time required to reach equilibrium. y = 0.8484x R 2 = 0.9967 y = 0.5652x R 2 = 0.9987 Limonene oxide concentration (ppm) Figure 7. Calibration curve for limonene oxide in limonene at part-per-million levels. A 7-µm PDMS fiber was used for sampling. Table III. Limonene Oxide Concentrations in Essential Oils, Juices, and Juice Drinks Sample cis-limonene oxide trans-limonene oxide Essential oils Orange oil 1.1% by mass 0.7% by mass Lemon oil 1.0% by mass 1.1% by mass Lime oil 0.2% by mass 0.1% by mass Fresh lemon oil None detected initially; None detected initially; 398 ppm after 3 weeks 414 ppm after 3 weeks Aqueous samples Tropicana pure None detected None detected premium orange juice Dole s strawberry None detected None detected kiwi drink Pink lemonade None detected None detected Calibration lower 0.1 ppm 0.1 ppm limit 34

All sampling was conducted at room temperature. Limonene and limonene oxide were sufficiently volatile so that liquid/vapor equilibrium was quickly established, and elevated temperatures were not needed to reduce sampling time (15). The low temperature was also useful in reducing the sampling of less volatile components. Acknowledgements This paper was presented at the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy in New Orleans, March 2002. Results and Discussion External standards were made of limonene oxide in limonene over the ranges 100 750 ppm and 0.1 18% by mass. A linear response was achieved for both concentration ranges with correlation coefficient values of R 2 from 0.995 to 0.999 (Figure 7). Several essential oils (Murray Brothers) and fresh lemon peel oil were analyzed for limonene oxide. Because the orange oil sample was used for much of the method development, this sample was analyzed first and was determined to contain 1.8% limonene oxide (cis and trans). Of the oils tested, the orange oil sample had the highest concentration. Results for other essential oils are listed in Table III. By comparison, although the major component in the fresh lemon peel oil was limonene, no limonene oxide was detected. To monitor oxidation of the limonene, the sample was tested weekly and stored in an amber sample vial. The vial cap was periodically removed to accelerate the formation of limonene oxide for this study. The limonene oxide concentration was 400 ppm when it was detected in the third week; daily monitoring would have detected the oxidation products sooner. The concentration continued to increased with time and exposure to air. External aqueous standards were made of limonene oxide for the analysis of beverages. The standards ranging from 0.1 100 ppm by volume showed a linear response (y = 141.56x for cis-limonene oxide and y = 105.75x for trans-limonene oxide) with R 2 = 0.9993 for cis-limonene oxide and 0.9982 for translimonene oxide. Calibration nonlinearity caused by variations in SPME sampling conditions has been overcome with the use of an internal standard in other applications (16,17), but this was not needed for the determination of limonene oxide. Samples of fruit juice and juice beverages were analyzed for limonene oxide. No limonene oxide was detected in these consumer products (Table III). Conclusion This method proved useful for monitoring the quality of fresh lemon oil and of consumer-quality citrus oils for candy making, baking, and aromatherapy. Analysis of citrus juices and juice drinks containing limonene demonstrated the effectiveness of additives because no limonene oxide was detected. This method of SPME sampling through HS can be applied to other limonenecontaining products to monitor oxidation rates. References 1. J. Pawliszyn. Solid-Phase Microextraction: Theory and Practice. Wiley-VCH, New York, NY, 1997. 2. J. Pawliszyn. Quantitative aspects of SPME. Applications of Solid- Phase Microextraction. J. Pawliszyn, Ed. Royal Society of Chemistry, Cambridge, U.K., 1999, pp. 3 21. 3. Z. Zhang and J. Pawliszyn. Headspace solid-phase microextraction. Anal. Chem. 65: 1843 52 (1993). 4. R. Eisent and K. Levsen. Solid-phase microextraction coupled to gas chromatography: a new method for the analysis of organics in water. J. Chromatogr. A 733: 143 57 (1996). 5. M.W. Cole III and B.M. Lawrence. A comparison of selected analytical approaches to the analysis of an essential oil. Flav. Frag. J. 12(1): 1 8 (1997). 6. J.A. Field, G. Nickerson, D.D. James, and C. Heider. Determination of essential oils in hops by headspace solid-phase microextraction. J. Agric. Food Chem. 44: 1769 72 (1996). 7. J.S. Elmore, M.A. Erbahadir, and D.S. Mottram. Comparison of dynamic headspace concentration on Tenax with solid-phase microextraction for the analysis of aroma volatiles. J. Agric. Food Chem. 45: 2638 41 (1997). 8. B. MacGillivray, J. Pawliszyn, P. Fowlie, and C. Sagara. Headspace solid-phase microextraction versus purge and trap for the determination of substituted benzene compounds in water. J. Chromatogr. Sci. 32: 317 22 (1994). 9. A. Steffen and J. Pawliszyn. Analysis of flavor volatiles using headspace solid-phase microextraction. J. Agric. Food Chem. 44: 2187 93 (1996). 10. J. Song, B.D. Gardner, J.F. Holland, and R.M. Beaudry. Rapid analysis of volatile flavor compounds in apple fruit using SPME and time-offlight mass spectrometry. J. Agric. Food Chem. 45: 1801 1807 (1997). 11. Z. Penton. Flavor volatiles in fruit beverages with automated SPME. Food Test. Anal. 2(3): 16 18 (1996). 12. J. Ai. Headspace solid-phase microextraction: dynamics and quantitative analysis before reaching a partition equilibrium. Anal. Chem. 69(16): 3260 66 (1997). 13. J. Ai. Quantitation by SPME before reaching a partition coefficient. Applications of Solid-Phase Microextraction. J. Pawliszyn, Ed. Royal Society of Chemistry, Cambridge, U.K., 1999, pp. 22 40. 14. X. Yang and T. Peppard. Solid-phase microextraction for flavor analysis. J. Agric. Food Chem. 42: 1925 30 (1994). 15. C.L. Arthur, L.M. Killam, K.D. Buchholz, and J. Pawliszyn. Automation and optimization of solid-phase microextraction. Anal. Chem. 64: 1960 66 (1992). 16. L.K. Ng, M. Hupe, J. Harnois, and D. Moccia. Characterization of commercial vodka by solid-phase microextraction and gas chromatography/mass spectrometry analysis. J. Agric. Food Chem. 70: 380 88 (1996). 17. D. Page. Analysis of volatile contaminants in food. Applications of Solid-Phase Microextraction. J. Pawliszyn, Ed. Royal Society of Chemistry, Cambridge, U.K., 1999, pp. 423 34. Manuscript accepted November 27, 2002. 35