Simultaneous analysis of the major metal cations and ammonium by CZE

Similar documents
Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Key Distance Learning Module I: Getting to Know Your Capillary

SCIEX Cation Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

3.1. Preparation of Buffer Solutions

Precision and accuracy of protein size determination using the ActiPix TDA200 Nano-Sizing System

Properties of Compounds

Organic Acids Analysis Kit

Supplementary information 1. INSTRUCTIONS FOR STUDENTS

New CE methods for the determination of inorganic ions and carbohydrates in real matrices

Biochemistry. Biochemical Techniques. 01 Electrophoresis : Basic Concepts

Ion Analysis with Agilent Capillary Electrophoresis Systems. Application Compendium

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Determination of Metal Ions in Algal Solution Samples by Capillary Electrophoresis

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

GENERAL INSTRUCTIONS GENERAL PREPARATION

NICKEL-63/59 IN WATER

Spectrophotometric Determination of Ferrocyanide in Effluents

CZE analysis of artificial sweeteners and preservatives in drinks

CH 4 AP. Reactions in Aqueous Solutions

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Conductivity of Electrolytes in Solution

Analysis of cations and anions by Ion- Selective Electrodes (ISEs)

Lab #3 Reduction of 3-Nitroacetophenone

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Chemistry Determination of Mixed Acids

Graphene oxide was synthesized from graphite using the MH (modified Hummer s method) 30 and

A covalent, cationic polymer coating method for the CESI-MS analysis of intact proteins and polypeptides

q oqo3 Waters Capillary Ion Analysis Method Direct UV Detection at 185 nm of InorganicAnions and Organic Acids 2000

Solutions. Experiment 11. Various Types of Solutions. Solution: A homogenous mixture consisting of ions or molecules

Determination of the inorganic ion composition of standing surface water

Water Hardness and Softening (Bring a water sample from home) Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.2.

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Experiment 10 Acid-Base Titrimetry. Objectives

SOLUBILITY PRODUCT (K sp ) Slightly Soluble Salts & ph AND BUFFERS (Part Two)

Operating Instructions for Ammonium ISE Specifications

Final NYB Fall 2009 Condensed Version (Working Spaces Removed)

Chem 321 Name Answer Key D. Miller

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Chapter 4. Aqueous Reactions and Solution Stoichiometry

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Separation Sciences. 1. Introduction: Fundamentals of Distribution Equilibrium. 2. Gas Chromatography (Chapter 2 & 3)

John Abbott College Department of Chemistry Chemistry 202-NYB-05 Sample Final Exam

Physical Separations and Chromatography

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Modified Adams Assay for Phenolics in Wine

Supplementary Material (ESI) for Chemical Communication

1.17 Capillary electrophoresis

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

CE Solutions.

Synthesis and Analysis of a Coordination Compound

Chapter 4: Types of Chemical Reactions and Solution Stoichiometry

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

Determination of transitions metal ions as complexes with 2, 6-pyridinedicarboxylic acid by capillary electrophoresis

Chemistry 20 Final Review Solutions Checklist Knowledge Key Terms Solutions

Quantitative chemistry Atomic structure Periodicity

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

columns IonPac SCS 1 Silica Cation Separator

EPSS 15 Introduction to Oceanography Spring The Physical and Chemical Properties of Seawater

100 C = 100 X = X = 218 g will fit in this solution. 25 C = 100 X = 3640 X = 36.4 g will fit in this solution.

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

ISO INTERNATIONAL STANDARD

Dilution(*) Chromatography

GENERAL INSTRUCTIONS GENERAL PREPARATION

Physical Chemistry Laboratory I Experiment 3 Effect of Ionic Strength on the Solubility of CaSO 4 (Revised, 01/13/03)

Concentration of Solutions

ProPac WCX-10 Columns

EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

ICSE Chemistry Model Paper-9

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Sampling and DNA Extraction from Wastewater Activated Sludge Standard Protocol

CHEMISTRY QUANTITATIVE AND QUALITATIVE ANALYSIS Fall 2008

4.1.1 (conductance) (conductivity)

Wed Sep 5, Characteristics of Water

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

BUFOTENINE Latest Revision: August 16, 2005

H 2 O WHAT PROPERTIES OF WATER MAKE IT ESSENTIAL TO LIFE OF EARTH? Good solvent High Surface tension Low vapor pressure High boiling point

DETERMINATION OF SMALL ANIONIC SULFUR SPECIES IN MAGNESIUM BASE BISULFITE COOKING LIQUOR BY CAPILLARY ELECTROPHORESIS (CE)

Solutions. Heterogenous Mixture (Not a Solution) Ice Water (w/ Ice Cubes) Smog Oil and Water

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

Experiment 7: The Synthesis of Artificial Hyacinth Odor (1-bromo-2-phenylethene), Part I

Chemistry 1B Experiment 11 49

Chemistry Instrumental Analysis Lecture 23. Chem 4631

Unit V: Solutions. A. Properties of Solutions. B. Concentration Terms of Solutions. C. Mass Percent Calculation. D. Molarity of Solutions

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Reference Manual. Program Help for Electrophoretic Buffer Studies. Version 1.3. Copyright 2001 ANALIS sa/nv

WEEK 2 EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

1-(2-METHOXYPHENYL)PIPERAZINE Latest revision: June 27, 2005

Transcription:

Simultaneous analysis of the major metal cations and ammonium by CZE This method has been published. You can download a copy of the PDF. Cite this method as: Warren CR, Adams MA (2004) Capillary electrophoresis of the major anions and cations in leaf extracts of woody species. Phytochemical Analysis 15: 407-413 DISCLAIMER Before using this or any other analytical method it is imperative that you check that it works with your samples. The bare minimum is to test accuracy and precision. Test accuracy by creating a standard curve by serial dilution of a sample and/or via spike and recovery tests. Both tests will show if the analysis is affected by the sample matrix. Test precision by repeated analysis of the same sample. It s best to do separate precision tests for the analytical method (replicate analyses of the same extract) and for the entire extraction and analysis procedure (extract the same sample several times and carry each extract through the analysis procedure). These tests will show you where poor precision is creeping into your analysis. Remember that your results are qualitative if you rely on a standard curve with a purified analyte. Introduction Separation of cations by capillary electrophoresis was first demonstrated some 20 years ago and in recent times determination of cations by CE has become widespread (Macka and Haddad 1997; Yang et al. 1995). CE requires only very small sample volumes and permits the simultaneous detection of different elements and thus is potentially faster than existing methods (e.g. IC). There are numerous CE methods suitable for the determination of metal cations and ammonium, but few have been tested on biological samples. Bazzanella et al. (1998) developed a CE method suitable for analysis of vacuolor sap extracted from wheat, and this is a modification of that method. 1.1 Detection Most cations lack chromophores and do not give a UV-Vis response. One elegant approach is to use indirect UV detection with a background electrolyte such as imidazole with a high UV absorbance. The background electrolyte provides a high background UV signal, when analytes pass the detector they reduce UV absorbance, thus analytes are detected as "negative peaks" against a high background. Indirect UV is thus a universal detection method it detects anything. The primary drawback of this is that it increases the possibility of interference from similarly charged species. 1.2 Separation In CZE (capillary zone electrophoresis) analytes migrate according to their mass/charge ratio. Hence a prerequisite of CZE is that analytes are charged. Any species that is a cation at ph 4.2 will thus migrate toward the cathode. Potassium and ammonium have similar electrophoretic mobility in an imidazole electrolyte, separation of one from the other is possible by adding the crown ionophore 18-crown-6, which forms complexes with potassium, increasing it s size and slowing down its migration. 2 Preparation of samples Samples generally require little pre-treatment before analysis. Samples such as phloem and xylem sap only require dilution prior to analysis. Analytes can be extracted from leaves with hot water,

methanol/chloroform/water(mcw), or aqueous ethanol. MCW extracts will be cleaner than hot water extracts and should present fewer problems for analysis. Proteins are present in hot water extracts (but not MCW), and these may be a problem for analysis since they bond to the inside of the capillary and consistently increase migration time. Protein-rich samples can be either precipitated with an organic solvent, TCA or ultrafiltered prior to analysis. References Bazzanella A, Lochmann H, Mainka A, Bächmann K (1997) Determination of inorganic anions, carboxylic acids and amino acids in plant matrices by capillary zone electrophoresis. Chromatographia 45: 59-62 Macka M, Haddad PR (1997) Determination of metal ions by capillary electrophoresis. Electrophoresis 18: 2482-2501 Warren CR, Adams MA (2004) Capillary electrophoresis of the major anions and cations in leaf extracts of woody species. Phytochemical Analysis 15: 407-413 Yang Q, Hartmann C, Smeyers-Verbecke J, Massart DL (1995) Method development and validation for the determination of mineral elements in food and botanical materials by capillary electrophoresis. J Chromatogr 717: 415-425 Yang Q, Jimidar M, Hamoir TP, Smeyers-Verbeke J, Massart DL (1994) Determination of alkali and alkaline earth metals in real samples by capillary ion analysis. J Chromatogr 673: 275-285

Materials and methods BGE: 10 mm imidazole, 2 mm 18-crown-6 Background electrolyte (BGE) should be prepared fresh whenever you wish to analyse a batch of samples. BGE probably lasts for a couple of weeks if tightly capped. To make 250 ml of 10 mm imidazole*, 2 mm 18-crown-6*: 1. Clean electrode and calibrate ph meter using fresh ph standards (ca. ph 3 and 5). 2. To a 250 ml erlenmeyer flask add: a magnetic stirrer bar; 0.1702 g of imidazole; 0.132 g of 18-crown-6; approx 230 ml of double DI water. 3. Place on a magnetic stirrer and heat to dissolve 4. Adjust ph to 4.2 with 1 or 0.1 M HCl 5. Make up to 250 ml with double DI water 6. Store in tightly capped container *Imidazole is toxic and corrosive *18-crown-6 is toxic and it lives in the fridge CE setup Capillary: bare fused silica 75 m i.d. x 50 cm effective length Cartridge and carousel temp: 20 C Polarity: positive to negative Run voltage:25 kv Run time: 5 minutes Detector: 200 nm, 10 nm bandwidth, 8 Hz, indirect detection Sample injection: 5 sec * 0.5 psi (standard, but can be changed if necessary) Purge cycles (2): 0.25 M HCl (1 min ), BGE (2 min) It is important that the capillary is rinsed with HCl and BGE prior to each run so as to ensure good reproducibility (see Figs 1b,c). Rinsing with NaOH causes a huge loss of resolution (see Fig 1a) and poor reproducibility. If the capillary is rinsed only with BGE reproducibility is poor, with large increases in MT between runs. Continual electrophoresis affects the electrophoretic properties of the BGE this leads to small increases in MT with every run. This increase stays well within acceptable limits if the BGE vials are replaced every 6-10 runs.

Table 1. Linearity and sensitivity of the method for analysis of the major metal cations and ammonium. The linearity of detector response (peak area) was assessed with standards over the range 0.01 to 1 mm. Detection limit was determined at a signal-to-noise ratio of 3. Cation Linearity (r 2 ) Detection limit (µm) NH 4 + 0.998 10.0 K + 0.999 7.5 Na + 0.999 0.3 Ca 2+ 0.999 0.4 Mg 2+ 0.999 0.3

Table 2. Reproducibility of migration time (MT) and peak area (Area) of cations in a standard solution and a sample. Reproducibility was determined by repeated injection (n = 6) of a mixture of the 5 cations at 0.1 mm each (Standard), or a 5-fold diluted hot-water extract from leaves of E. globulus (Sample). %RSD, percentage relative standard deviation. Standard Sample Cation MT (%RSD) Area (%RSD) MT (%RSD) Area (%RSD) NH 4 + 0.099 4.9 0.17 12.5 K + 0.11 5.7 0.18 3.0 Na + 0.15 5.1 0.19 6.2 Ca 2+ 0.13 1.7 0.20 3.5 Mg 2+ 0.09 5.4 0.20 2.4

Figure 1. Electropherograms of cations in a) standard mixture of 0.1 mm cations, b) first injection of a standard mixture, c) 10 th injection of the same standard mixture, and d) hot-water extract from E. globulus diluted 5-fold with water. In electropherogram a) the capillary was rinsed with 0.25 M NaOH and BGE prior to injection. In b), c) and d) the capillary was rinsed with 0.25 M HCl and BGE prior to injection. CE conditions: capillary, bare fused silica, 57 cm total length, 50 cm effective length x 75 µm i.d.; BGE, 10 mm imidazole, 2.0 mm 18-crown-6, ph 4.2; applied voltage, 25 kv; temperature 20 C. Detection was by indirect UV at 200 nm with a reference at 350 nm. Peaks have been inverted for display. Peaks are: 1, ammonium; 2, potassium; 3, sodium; 4, calcium; 5, magnesium Absorbance at 200 nm d c b 1 2 3 4 5 rep 10 rep 1 a 100 150 200 250 300 Time (seconds)