Reservoir Monitoring Using Hybrid Micro-Gravity Measurements in the Takigami Geothermal Field, Central Kyushu, Japan

Similar documents
or

Hybrid Gravimetry for Optimization Time Lapse Monitoring Data: A case study in Kamojang Geothermal Field

HEAT AND MASS TRANSFER PROCESSES AFTER 1995 PHREATIC ERUPTION OF KUJU VOLCANO, CENTRAL KYUSHU, JAPAN

CONTINUOUS GRAVITY MEASUREMENTS FOR RESERVOIR MONITORING. M. Sugihara

ABSOLUTE GRAVITY MEASUREMENTS

Reservoir Monitoring in the Okuaizu Geothermal Field Using Multi-Geophysical Survey Techniques

Estimation of Subsurface Structure in the Western Fukuoka City fromgravity Data

Absolute and Relative Gravity Measurements at the Istituto Nazionale di Ricerca Metrologica (INRIM) of Turin (Italy) in June 2006

DEVELOPMENT OF THE OPTIMUM NUMERICAL RESERVOIR MODEL OF THE TAKIGAMI GEOTHERMAL FIELD, OITA, JAPAN

Preliminary Microgravity Measurement Of Paka Geothermal Prospect

Final Report. January Prof. Dr. Olivier Francis

Intermediary Report - August Prof. Dr. Olivier Francis and Prof. Dr. Tonie Van Dam

Numerical Simulation of Devolution and Evolution of Steam-Water Two-Phase Zone in a Fractured Geothermal Reservoir at Ogiri, Japan

Repeat Microgravity and Leveling Surveys at Leyte Geothermal Production Field, North Central Leyte, Philippines

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Using Repeat Microgravity Measurements to Track Reinjection in Liquid-Dominated Fields

Hijiori HDR Reservoir Evaluation by Micro-Earthquake Observation

Numerical Simulation Study of the Mori Geothermal Field, Japan

ABSOLUTE GRAVITY MEASUREMENTS IN LOMONOSOV, SAINT-PETERSBURG, RUSSIA

Practical Application of Directional Drilling at Takigami Geothermal Field

New Energy and Industrial Technology Development Organization (NEDO), Tokyo, Japan. Average power through the year Authorized rated output

Intercomparison of Relative and Absolute Gravimeters. Olivier FRANCIS

RECHARGE ELEVATION OF HOT SPRING STUDY IN THE MT

THREE DIMENSIONAL MODELING OF GEOELECTRICAL STRUCTURE BASED ON MT AND TDEM DATA IN MORI GEOTHERMAL FIELD, HOKKAIDO, JAPAN

Monitoring of geothermal reservoirs by hybrid gravimetry

Shuzo Takemoto*, Yoichi Fukuda*, Toshihiro Higashi*, Maiko Abe*, Shihori Ogasawara*, Sjafra Dwipa**, Dendi Surya Kusuma** & Achmad Andan**

ASSESSMENT OF GEOTHERMAL POTENTIAL AT UNGARAN VOLCANO, INDONESIA DEDUCED FROM NUMERICAL ANALYSIS

Study of Hydrometeorology in a Hard Rock Terrain, Kadirischist Belt Area, Anantapur District, Andhra Pradesh

Takigami geothermal system, northeastern Kyushu, Japan

To the best of our knowledge, the FG5 gravimeter represents the current state-of-the-art in the measurement of absolute gravity.

3D Numerical model of the Obama hydrothermal geothermal system, Southwestern Japan

A Report on a Statistical Model to Forecast Seasonal Inflows to Cowichan Lake

GEOTHERMAL AND HOT SPRING WATER ORIGIN DETERMINATION USING OXYGEN AND HYDROGEN STABLE ISOTOPE IN THE TOYOHIRAKAWA CATCHMENT, HOKKAIDO, JAPAN

3D MAGNETOTELLURIC SURVEY AT THE YANAIZU-NISHIYAMA GEOTHERMAL FIELD, NORTHERN JAPAN

GM 1.4. SEG/Houston 2005 Annual Meeting 639

Japan Engineering Consultants, Inc., Energy and Industrial Technology Development Organization,Tokyo, Japan

MODELING AND NUMERICAL ANALYSIS OF THE TWO-PHASE GEOTHERMAL RESERVOIR AT OGIRI, KYUSHU, JAPAN

ABSOLUTE AND RELATIVE GRAVITY MEASUREMENTS AT ETNA VOLCANO (ITALY)

Geophysical Monitoring Researches for CO 2 Geological Storage. Shinsuke NAKAO Geological Survey of Japan, AIST

Development of a Borehole Gravity Meter for Mining Applications

LOCATING AND CHARACTERIZING ABANDONED MINES USING MICROGRAVITY by Richard C. Benson 1, Ronald D. Kaufmann 1, Lynn Yuhr 1, Richard Hopkins 2 ABSTRACT

ONE YEAR WITH OUR ABSOLUTE GRAVIMETER

NUMERICAL MODELING STUDY OF SIBAYAK GEOTHERMAL RESERVOIR, NORTH SUMATRA, INDONESIA

Chiang Rai Province CC Threat overview AAS1109 Mekong ARCC

** New Energy and Industrial Technology Development Organization (NEDO) Keisoku Co., Ltd. (CK)

RESPONSE OF WAIRAKEI GEOTHERMAL RESERVOIR TO 40 YEARS OF PRODUCTION

Case study of Japan: Reference Frames in Practice

GRAVITY AND MAGNETIC METHODS

GEOTHERMAL ENERGY EXPLORATION IN UGANDA, COUNTRY UPDATE 2006

KMS Technologies KJT Enterprises Inc. Presentation

Conceptual model for non-volcanic geothermal resources - examples from Tohoku Japan

New Developments in Gravity Applications and Instruments

3D temporal evolution of displacements recorded on Mt. Etna from the 2007 to 2010 through the SISTEM method

Technical Note: Hydrology of the Lukanga Swamp, Zambia

Name Period Part I: INVESTIGATING OCEAN CURRENTS: PLOTTING BUOY DATA

Verification and Validation Calculations Using the STAR Geophysical Postprocessor Suite

Keywords: Elevation, gravity, geothermal ABSTRACT

Integrated Interpretation of Gravity, Magnetic & Seismic data for delineation of Basement Configuration in Sadiya Block, Upper Assam, India

Multi-scale evaluations of submarine groundwater discharge

Strategy of 4D Microgravity Survey for the Monitoring of Fluid Dynamics in the Subsurface

FG5 Absolute Gravimeter

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Geophysics for Geothermal Exploration

Prediction of Calcite Scaling at the Oguni Geothermal Field, Japan: Chemical Modeling Approach

INTERPRETATION OF INTERFERENCE EFFECTS IN THREE PRODUCTION WELLS IN THE KAWERAU GEOTHERMAL FIELD, NEW ZEALAND. Lynell Stevens and Kevin J Koorey

Gravimetric Tide observation at Lake Nasser Region, Aswan, Egypt

Magnetic and Gravity Methods for Geothermal Exploration

Investigation of submarine groundwater discharge using several methods in the inter-tidal zone

Istituto Nazionale di Ricerca Metrologica

A distributed runoff model for flood prediction in ungauged basins

Bifurcation Current along the Southwest Coast of the Kii Peninsula

YOKOYAMA (1977) have recently reported the oceanic effects in the coastal

GEOTHERMAL POWER PLANT SITE SELECTION USING GIS IN SABALAN AREA, NW IRAN

Local to Regional Hydrological Model Calibration for the Okavango River Basin from In-situ and Space Borne Gravity Observations

2006 Drought in the Netherlands (20 July 2006)

AN ASSESSMENT OF THE RELATIONSHIP BETWEEN RAINFALL AND LAKE VICTORIA LEVELS IN UGANDA

Absolute Gravity Observation at the National Measurement Institute


Automatic weather station research by Japanese Antarctic Research Expedition in East Droning Maud Land, East Antarctica.

ESTIMATION OF HORIZONTAL ILLUMINANCE BY MEASURED SKY LUMINANCE DISTRIBUTION

Aseismic slip and low-frequency earthquakes in the Bungo channel, southwestern Japan

The Climate of Texas County

Mount Stromlo Gravity Station Gravimetry at the ANU

Università degli Studi di Napoli Federico II, Dipartimento di Scienze della Terra Napoli, Italy

Keywords: geophysics field camp, low to moderate, temperature, geothermal system, Mt Pancar, Indonesia

Development of System for Supporting Lock Position Adjustment Work for Electric Point Machine

Blind fault Configuration in Osaka, Japan based on 2D gravity inversion

Integrated gradient interpretation techniques for 2D and 3D gravity data interpretation

Geothermal Systems: Geologic Origins of a Vast Energy Resource

Computer Activity #3 SUNRISE AND SUNSET: THE SEASONS

Trevor M. Hunta and Warwick M. %slingb

GIS INTEGRATION METHIOD FOR GEOTHERMAL POWER PLANT SITEING IN SABALAN AREA, NW IRAN

Precision Gravimetry in the New Zugspitze Gravity Meter Calibration System

Analysis of Rainfall and Other Weather Parameters under Climatic Variability of Parbhani ( )

Daily Rainfall Disaggregation Using HYETOS Model for Peninsular Malaysia

Topic 7: Geophysical and Remote Sensing Models. Presenter: Greg Ussher Organisation:SKM

Evaluation of tsunami force on concrete girder by experiment simulating steady flow

Geothermal Reservoir Characterization by SP Monitoring

Gravity in the Ryukyu Arc*

Absolute gravimetry. Gabriel Strykowski Geodynamics Department DTU-Space (formerly Danish National Space Center)

Transcription:

Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 Reservoir Monitoring Using Hybrid Micro-Gravity Measurements in the Takigami Geothermal Field, Central Kyushu, Japan Jun Nishijima, Hakim Saibi, Yayan Sofyan, Sachio Shimose, Yasuhiro Fujimitsu, Sachio Ehara, Yoichi Fukuda, Takashi Hasegawa and Makoto Taniguchi Laboratory of Geothermics, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan nishijima@mine.kyushu-u.ac.jp Keywords: reservoir monitoring, hybrid micro-gravity measurement, Takigami geothermal field ABSTRACT Repeated gravity measurements have been applied at the Takigami geothermal power plant in central Kyushu, Japan. We applied a multivariate regression model and removed the effects of shallow groundwater level change in order to extract the gravity change associated with the production and reinjection of geothermal fluids. We used Scintrex CG- 3 and CG-3M gravimeters to measure precise gravity change. We detected gravity changes caused by the production and reinjection. However, we cannot assess the gravity change at the reference station, because we only used the relative gravimeter. Hence we introduced the A10 absolute gravimeter (Micro-g LaCoste, Inc) for not only the assessment of the gravity changes at the reference station, but also the detection of the gravity change caused by the underground fluid flow changes. Hence we introduced the A10 absolute gravimeter (Micro-g LaCoste, Inc) for not only the assessment of the gravity changes at the reference station, but also the detection of the gravity change caused by the underground fluid flow changes. We will report the result of the fluid measurements. 1. INTRODUCTION Some procedures are suggested in order to monitor reservoir changes. Micro-gravity measurement is one of the procedures for geothermal reservoir monitoring. The production and reinjection of geothermal fluid causes mass movement and redistributions, which can cause measurable gravity changes on the surface. We can monitor the mass balance, especially the relation between production and recharge, in the geothermal reservoir. Repeated microgravity measurements have been carried out in some geothermal fields. Gravity decreased about 1000µgal after 30 years in the Wairakei geothermal field, New Zealand (Allis and Hunt, 1986). We started repeated micro-gravity measurement before the commencement of Takigami geothermal power plant using Scintrex CG-3 and CG-3M gravimeters to measure precise gravity change (Figure 1). We applied a multivariate regression model and removed the effect of shallow groundwater level change in order to extract the gravity change associated with the production and reinjection of geothermal fluid (Nishijima et al., 2000). We detected gravity decrease and increase in the production and reinjection zone, respectively. These gravity changes are consistent with the changes in mass balance in the geothermal reservoir. This study suggests that repeated gravity measurement is an effective method to monitor geothermal systems. In a relative gravity measurement, we assumed that the gravity at the reference station does not change. But observed gravity changes include the uncertainty of the reference station, and we cannot separate this uncertainty using relative gravity measurement. Absolute gravimetry can measure the temporal gravity change unequivocally. 1 Figure 1: Distribution of observation points (No. 1 to 27) for the repeat gravity measurement at Takigami geothermal field. 2. TAKIGAMI GEOTHERMAL FIELD Takigami geothermal field is located in the southwestern part of Oita prefecture, central Kyushu, Japan. Geothermal exploration was started in 1979 with various surveys and drilling. The power plant (25MW) was completed in November 1996. The geothermal steam production is conducted by Idemitsu Oita Geothermal Co., Ltd and the electric power generation is conducted by Kyushu Electric Power Co., Inc. The production area is located in eastern shallow (700-1100m depth) part and western deep (1500-2000m depth) part (Takenaka et al., 1995). The production depth is about 2500m and the reinjection depth from 1000m to 1500m. The amount of production is about 12Mt/year, and about

Nishijima et al. the 85% of production is reinjected to the underground not to cause the ground subsidence. 3. GRAVITY MEASUREMENT 3.1 Relative Gravity Measurement Repeated gravity measurements have been applied at Takigami geothermal power plant in central Kyushu, Japan. We conducted repeated gravity measurements in May 1991, at 26 observation points. The repeated gravity measurements were conducted in the interval of a few weeks to several months. The two-way measurement method was taken to evaluate the instrumental drift and precision. We estimated the errors of observation as ±10 µgal at each study field. 3.2 Absolute Gravity Measurement The A10 absolute gravimeter is a portable absolute gravimeter produced by Micro-g LaCoste Inc. It operates on a 12V DC power supply (i.e. vehicle battery). We can measure the absolute gravity using the vehicle battery at the field. The principle of this instrument is simple. A test mass is dropped vertically in a vacuum chamber, and then allowed to fall an average distance of 7 cm. The A10 uses a laser, interferometer, long period inertial isolation device and an atomic clock to measure the position of the test mass very accurately. The raw gravity data are processed with the software g version 7. This software is designed to work with the Micro-g LaCoste absolute gravimeter to acquire and process the gravity data. And this software needs the input of some parameters, including the location of the site (Latitude, Longitude and Altitude), geophysical corrections, and so on. We can correct the effects of the earth tide, ocean load, barometric pressure and polar motion in acquiring the gravity data. 4. EFFECTS OF SHALLOW GROUNDWATER It is necessary to estimate the effect of shallow groundwater changes to detect changes in deep geothermal fluid flow by the repeated gravity measurements. By extending the theory of the autoregressive model (Koike et al., 1995), a multivariate regression model is constructed relating the changes of shallow ground water level to gravity changes: y t = m i= 0 βix t i + ε where y t is a response variable, x t is an explanatory variable with β the coefficient of regression, m is an optimum degree of fit, ε is white noise. We quantitatively estimated the effect of background gravity change using a precipitation-gravity correlation. Figure 2 shows the comparison between the observed and estimated gravity in the production and reinjection zones. As a result, the optimum degrees were decided as between three and eight. This means that precipitation exerts the influence on gravity for a period between three and eight months previous to the gravity measurements. The estimation accuracy of the background gravity is ±10µgal. Before exploitation, there is good agreement between the observed and estimated gravity. However, there are differences up to 40 µgal between observed and estimated gravity just after the commencement of exploitation. The differences in the observed and estimated gravity show the gravity change associated with the production and reinjection of geothermal fluid. 5. RESULT AND DISCUSSIN 5.1 Relative Gravity Measurement According to the result of leveling surveys, there are vertical ground movements in Takigami geothermal field. These ground movements are less than 1cm/year. Assuming a normal free-air gradient of -308.6µgal/m, ground movement causes less than 3µgal. This effect is very small in comparison with the observed gravity change. Consequently, the effect of vertical ground movement is negligible on the observed gravity in short term (several years). But we can t assume long-term (more than 10 years) vertical ground movements to be negligible. Therefore we corrected the effect of vertical ground movement using the leveling survey result. i 50 T14 0 Gravity changes (microgal) -50-100 -150-200 -250-300 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 Figure 2: Comparison between the observed and calculated gravity changes at Takigami geothermal field. 2

The residual gravity changes (due to reservoir effects), taken as the difference between the observed and the calculated gravity effect of ground water level changes at each observation station, can be subdivided into four types of response (Figure 3). The data suggest there were decreases of residual gravity (up to 80 µgal) in the production zone and increases of residual gravity (up to 10 µgal) in the reinjection zone just after the production and reinjection started. geothermal power plant. The center of residual gravity decrease is located just to the south of the power plant. The center of this change is located in the basin structure. The mass movement associated with the production of the geothermal fluid occurred in the basin structure. 5.1.1 West Area This group is located along Nogami river, and gravity changes are small compared with other groups. As soon as the production and reinjection of the geothermal fluid begins a slight decrease of the residual gravity is seen. Gravity decreases from July 1999 until July 2002, and then starts increasing. 5.1.2 Southwest Area This group of response is seen at observation points located in the production zone along the Teradoko fault, in the southwestern part of the observation area. Gravity decreases from the onset of production until July 2002, and then starts increasing. 5.1.3 East Area This group of response is typical of stations located in the eastern production zone along the Noine fault, in the eastern part of the observation area. A decrease of residual gravity was seen immediately after the geothermal fluid production started, and between June and August 1996 gravity increased sharply. After that, residual gravity gradually increased. Figure 4 shows the contour map of gravity changes from 1996 to 1997 just after the commencement of Takigami Figure 4: Distribution of gravity changes from 1996 to 1997. Figure 3: Distribution of typical patterns of residual gravity changes in the Takigami geothermal field. 3

Figure 5 shows the contour map of gravity changes from 2003 to 2007. The gravity changes recovered in this period. Some stations reached their former level. The center of residual gravity increase is located in the southwestern part of the power plant. It seems like the recharge of geothermal fluid comes from southwestern part of the field This study suggests that repeated gravity measurement is an effective method to monitor geothermal reservoirs. These residual gravity changes are consistent with the changes in mass balance in the geothermal reservoir. Thus, the effects of field operations can be isolated, even for fields with relatively low production rates like the Takigami geothermal field. Figure 6: Mass balance based on the contour map of gravity changes at Takigami geothermal field from 1996 to 1997. Figure 5: Distribution of gravity changes from 2003 to 2007. Application of Gauss s Potential Theorem (La Fehr, 1965) to gravity changes gives a quantitative estimate of the mass changes. We based our changes on the contour map of the gravity (Figure 4 and Figure 5). Figure 6 shows the mass balance from 1996 to 1997 just after the commencement of Takigami geothermal power plant. Mass decrease determined by gravity change from 1996 to 1997 is 8.83 Mt. The total discharge, difference between produced (10.53 Mt) and reinjected (8.53 Mt) mass, was 2.0 Mt. The difference between the total discharge and the mass decrease is thought to be a natural mass recharge (-6.83Mt) from the surrounding area. The negative natural mass recharge indicates that the production of geothermal fluid exceeds the recharge from the surrounding area. Figure 7 shows the mass balance from 2003 to 2007. In this period, Mass decrease determined by gravity change is 0.48 Mt. The total discharge, difference between produced (11.44 Mt) and reinjected (10.11 Mt) mass, was 1.78 Mt. The difference between the total discharge and the mass decrease is thought to be a natural mass recharge (2.26Mt) from the surrounding area. This estimation suggests that a large amount of the geothermal fluid was recharged and underground fluid flow is reaching a new equilibrium state. 4 Figure 7: Mass balance based on the contour map of gravity changes at Takigami geothermal field rom 2003 to 2007. 5.2 Absolute Gravity Measurement We chose the 4 stations (T13, T22, T26 and T27) to conduct the repeated gravity measurement using a vehicle battery. We conducted absolute gravity measurement three times (Feb., Apr. and Dec., 2008). A regular repair was carried out on April 2008. Production and reinjection were interrupted in this period. We tried to detect the influence of stopping the production and reinjection of geothermal fluid. The obtained gravity data is combined into a set which usually consist of 100-150 drops. Our typical setup parameters are listed below: Drop interval : 1 second Number of drops/set : 100 Set interval : 2 minutes Number of set : 10 Figure 8 shows the result of absolute gravity measurement. We observed gravity decrease just after the regular repair in the reinjection zone (T26A). After that the gravity recovered in December. These changes seem to be caused

by the change of reinjection. On the other hand, we did not detect the gravity change just after the regular repair in the production zone (T27A). But we detect the gravity decrease at the all stations located in the production zone. In the T26A, the gravity changes are very small (less than 20 µgal) compared with the production area. This station seems well suited to be the reference station for the relative gravity. But we don t have data from the rainy season. We will then measure the absolute gravity in a rainy season. 6. CONCLUSION We started repeated gravity measurements about 5 years ago before the beginning production and reinjection at the Takigami geothermal field. Based on these result, we estimated the background gravity change that is caused by seasonal changes of shallow ground water level by using a multivariate regression model relating gravity to precipitation. As a result, we were able to decide the background gravity change with an accuracy of ±20µgal. We can use the correlation to eliminate the effects of background gravity change. Residual gravity increases of up to 10 µgal were detected in the reinjection zone, and residual gravity decreases of up to 40 µgal were detected in the production zone. These residual gravity changes are consistent with the changes in mass balance in the geothermal reservoir. Thus, the effects of field operations can be isolated, even for fields with relatively low production rates like Takigami. This study suggests that repeated gravity measurement is an effective method to monitor geothermal reservoirs. Figure 8: Absolute gravity data at the Takigami geothermal field. T26A is located in the reinjection zone, the others is located in the production zone. 5

REFERENCES Allis, R. G. and Hunt, T. M.: Analysis of exploitation induced gravity changes at Wairakei geothermal field. Geophysics, Vol. 51, (1986), pp.1647-1660. Koike, K., Doi, E. and Ohmi, M.: Seasonal fluctuations and analysis of ground-water level using multivariate regression model, Geoinformatics, 2, (1991), 255-263. La Fehr, T. R.: The estimation of the total amount of anomalous mass by Gauss s Theorem, Jour. Geophys. Res., Vol. 70, (1965),1911-1919. Micro-g LaCoste Inc. A10 Portable Gravimeter User s Manual, (2006), 7. Nishijima, J., Shimosako, N., Motoyama, T., Fujimitsu, Y., Ehara, S., Ikeda, K., Akasaka, C., Furuya, S., Gotoh, H., and Motomatsu, T.: Gravity Monitoring of Geothermal Reservoirs in the Takigami Geothermal Field, Central Kyushu, Japan - Gravity Changes Caused by Production and Reinjection of Geothermal Fluids -, Journal of the Geothermal Research Society of Japan, 22, (2000), 117-130. Takenaka, T., Gotoh, H., Yamamoto, Y. and Furuya, S.: Exploration and development of the Takigami geothermal system, Kyushu, Japan, Journal of the Society of Resource Geology, 45, (1995), 361-376 (in Japanese with English abstract). 6