MassHunter TOF/QTOF Users Meeting

Similar documents
MassHunter Software Overview

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Making Sense of Differences in LCMS Data: Integrated Tools

Agilent All Ions MS/MS

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Die Nadel im Heuhaufen

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Agilent MassHunter Quantitative Data Analysis

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent MassHunter Quantitative Data Analysis

Application Note. Authors. Abstract. Introduction. Environmental

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

The new Water Screening PCDL

Extend Your Metabolomics Insight!

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Application Note. Edgar Naegele. Abstract

Information Dependent Acquisition (IDA) 1

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

WADA Technical Document TD2003IDCR

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Cerno Application Note Extending the Limits of Mass Spectrometry

TUTORIAL EXERCISES WITH ANSWERS

Agilent ESI and APCI sources: for polar to non-polar compounds

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

QTOF Small Molecule Applications Update. April 10 th, David A. Weil. Application Scientist, Schaumburg, IL

Multi-residue analysis of pesticides by GC-HRMS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

WADA Technical Document TD2015IDCR

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Compounding insights Thermo Scientific Compound Discoverer Software

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Tutorial 2: Analysis of DIA data in Skyline

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

ProMass Deconvolution User Training. Novatia LLC January, 2013

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

Theory and Practical Consequences.

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Agilent Technologies LCMS Portfolio

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Identifying Disinfection Byproducts in Treated Water

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Analyst Software. Peptide and Protein Quantitation Tutorial

UNIFI - Targeted and Untargeted Screening MS Software

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

MetWorks Metabolite Identification Software

Workflow Using Hyphenated Mass Spectrometry Techniques

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Protein Deconvolution Version 2.0

Welcome! Course 7: Concepts for LC-MS

Computer-assisted analysis of complex natural product extracts

Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note

SRM assay generation and data analysis in Skyline

Agilent Technologies at TIAFT 2013

Cerno Application Note Extending the Limits of Mass Spectrometry

Automated and accurate component detection using reference mass spectra

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Agilent G3212 GC-APCI Source

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

LC-MS. Pre-processing (xcms) W4M Core Team. 22/09/2015 v 1.0.0

Tutorial 1: Setting up your Skyline document

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

What s New in NIST11 (April 3, 2011)

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

Application Note. Edgar Naegele. Abstract

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

Building Inflation Tables and CER Libraries

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

OECD QSAR Toolbox v.4.1. Tutorial illustrating new options for grouping with metabolism

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Transcription:

MassHunter TOF/QTOF Users Meeting 1

Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A Workflow consists of three parts: A default method for the Workflow with the parameters and report templates already set for that type of task. A specified layout of the user interface that only shows the windows and table columns that the user needs to see. A new section at the top of the Method Explorer (called a workflow section) which groups together the tabs a user may need while performing a task: 5

Applying a Workflow Configuration Configure for Workflow in the menu bar You will see a warning that applying the Workflow will make changes 7

Using a Workflow After applying the Workflow, go through each tab in the workflow section sequentially to adjust the parameters for your task: 8

Isotope Distribution Calculator There is a standalone Isotope Distribution Calculator included with Qualitative Analysis at: C:\Program Files\Agilent\MassHunter\Workstation\Qual\B.0x.00\Bin\IsotopeDistributionCalculator.exe. Or under Start menu under: In B.03.01 or later: All Programs Agilent MassHunter Workstation Qualitative Analysis B.0x.00 Tools It allows you to model the theoretical abundances and spacing of any particular compound: 12

How To Determine Complexity of Sample/Matrix Acquire MS or AutoMSMS Modes Base Peak Chromatogram Excludes Major Components reference masses Find Compounds by Molecular Feature Extraction (MFE) Base Peak Chromatogram with Exclude m/z 195.09145 +/- 100 ppm 14

Find Compounds by Molecular Feature Results Over 280 Compounds Found in Coffee Spiked with Pesticide 15

Molecular Feature Extractor (MFE) Transforming Data into Chemical Information Raw data Background noise removed Individual m/z peaks grouped into isotope clusters Isotope clusters grouped into molecular features Identification, Quantification, Differential Analysis are performed on chemically qualified compound data 31

Find by Molecular Feature 19

Method Editor MFE 20

Method Editor MFE (cont d) 21

Method Editor MFE (cont d) Similar compounds (e.g. metabolites) will have similar mass defects, so we can use the Mass Defect tab to filter on that. 22

MFE Results 23

Find Compounds by Molecular Feature Results Over 280 Compounds Found in Coffee Spiked with Pesticide 24

Compound List Use found compounds for further analysis: Use Molecular Formula Generator (MFG) on list. Search a Database and match findings Upload the MFE results to Mass Profiler or GeneSpring MS for analysis. 25

Find Compounds by Formula Find Compounds in analysis by inputting: Formulas separated by, CEF file with Formulas A database with Formulas (.csv,.mtl,.cdb) Worklist Formulas 26

Find Compounds by Formula - Options Input Formula Source 28

Find Compounds by Formula Sample Purity Enables the user to do Sample Purity (not Peak Purity) calculations based on the same algorithms as LC/MS ChemStation Sample Purity compares a peak against all other peaks in the data file to determine the estimated purity of the compound After doing a Find Compounds by Formula, pure compounds are marked green and impure are marked yellow 29

Find Compounds by Formula System Suitability Integrate (UV) and Find by Formula Sample Purity It allows the user to calculate system suitability values on a UV chromatogram based on the chosen Pharmacopoeia The results are displayed in the Integration Peak List. 30

System Suitability Calculations Can Be Done for MS, MS/MS, UV and GC Chromatograms 31

Find Compounds by Formula Results Compounds Found Formulas Found 33

Find Compounds by Auto MS/MS Auto MS/MS Data Acquisition function used when the m/z value of the precursor ion is unknown prior to analysis. The instrument acquires a mass spectrum then determines ions meeting preset criteria for precursor ions. MS/MS spectra are taken for each identified precursor. The instrument then switches back to MS operation. Find by Auto MS/MS Data Analysis function used to automatically identify compounds in MS/MS data and create averaged MS and MS/MS spectra for each compound. The functionality is an easy way to mine information from complex data. MS Scan - Precursor Reference Mass Precursor Ion Reference Mass Product Ions MS/MS Scan Product Ions Precursor Ion 34

Start with MS/MS Data Very complex data. Difficult to obtain information. Page 35

Find by Auto MS/MS Algorithm User-specified excluded ions and persistent background are removed from the Auto MS/MS data file. The remaining spectra are then are divided into groups that represent scans from the same compound. This is done (first for positive ion scans, then for negative ion scans) by finding scans that: Have the same precursor m/z within a user-specified tolerance, and Have retention times within a user-specified window of each other, and Have a TIC value that exceeds a user-specified threshold Best Value is to Find Compounds Based on Product Ion Filters 37

Auto MS/MS Parameters Data to be found As of B.03.01 - Can filter results by fragments Appropriate Symmetry for Q-TOF: 10-100 ppm Exclude Reference Masses 38

Find by Auto MS/MS Results MS MS/MS 39

Compound List 40

Find Compound by Integration New function that is similar to Integrate and Extract Peak Spectra. Results are in the form of Compounds rather than Peaks and User Spectra. 42

Find Compound by Integration Best used when compounds are chromatographically separated. Creates Compounds which may be exported as a CEF file. Better labeling after library search than User Spectra: Easer to understand Finds more low level ions 43

Find Compound by Integration Integrator and Peak Filter parameter settings are unique to Find Compounds by Integration. 44

Find Compound by Integration Exclude Mass(es), Peak Spectrum Extraction, Charge State & Results are shared with other method sections. 45

Find Compound by Integration Specify the type of chromatogram to extract & integrate: Will extract the chromatogram even if it is already present. Duplicate TIC when run. Not required to extract the signal in File Open Action. Cannot be used on user defined chromatograms (example EIC). 46

Find Compound by Integration Optional - Extract additional chromatogram (not integrated) Optional - Restrict m/z range on BPC 47

Find Compound by Integration Adjust Delay Time Will adjust the RT of other signals compared to MS. Applied to GC, TWC, etc. signals when signal is extracted, not after. 48

Find Compound by Integration When User Interface Configuration has LC checked the Adjust Delay Time feature is active when extracting signals! 49

Find by Targeted MS/MS Algorithm This algorithm extracts a chromatogram for each targeted mass in the data file. This chromatogram is integrated and if the peaks are not eliminated by one of the filters on this tab, a compound is generated. The algorithm uses the targeted masses input in the acquisition method. 50

Find by Targeted MS/MS Results 51

Find by Targeted MS/MS Can extract MS/MS spectra based on collision energy 52

Identify Compounds Search a Database or Library after Find Compounds Generate Formulas after Find Compounds *Sequence editing 53

Database Searching Search Mode 54

Automated Compound Search METLIN Database 55

Accurate Mass Database vs. Library Database: contains an accurate mass, possibly a retention time, and other compound attributes such as CAS ID and the chemical structure for each compound. Accurate Mass Library: contains the same information as a Database plus MS/MS spectra. By convention, Databases are kept in D:\MassHunter\databases and Libraries are kept in D:\MassHunter\Library Libraries from Agilent have the suffix Lib in the name, e.g. SulfasLib.cdb 57

Accurate Mass Database vs. Library (cont.) When users search an Accurate Mass Database, they are searching for a specific accurate mass (e.g. 156.0761) against the accurate masses listed in the Database. When users search a Library, they are searching for a spectrum against the spectra in the Library. Unit Mass Library Search: accessed by turning on the GC Separation Type in the User Interface Configuration dialog box. The Library Editor for Unit Mass Libraries can be accessed by installing Quantitative Analysis. 58

Accurate Mass Database Searching If an Accurate Mass Database Search finds a compound, it will place the chemical structure in the Product Ion Spectrum and display the structure in the Structure Viewer pane (must be toggled On). Any links to outside information sources about the compound (e.g. Chemical Abstract Service #, CAS) are active click on them to go to a web site. 59

Accurate Mass Library Searching If an Accurate Mass Library Search finds a compound, it will place the chemical structure in the Product Ion Spectrum and display the structure in the Structure Viewer pane (if it is toggled On). Acquired Spectrum It is also possible to display a difference spectrum for the Library hit by toggling the Difference Results button to On in the main toolbar. Library Spectrum Difference Spectrum 60

All Ions MS/MS 61

Why All Ions MS/MS? -The EU s SANCO 12495 compliant screening requires: At least 2 product ions Final confirmation with a reference compound -Fully developed workflow in All Ions MS/MS for compound confirmation and quant method setup. Easy Acquisition method setup Targeted identification of product ions using Agilent s MS/MS libraries Chromatographic confirmation of product ions (coelution score) Rapid Quant method development automatically selects two high quality product ions for each compound, eliminating tedious manual steps -Be prepared for unexpected compounds in the sample -QQQ-like easy acquisition method setup -Productivity tool for faster analysis - Identification and fragment finding done in MH Qualitative Analysis - Routine quantitation and confirmation done in MH Quantitative Analysis 62

All Ions MS/MS Targeted Screening Workflow Acquisition PCDL Qual Quant MassHunter Acquisition m/z, ion species Find by Formula on MS low channel High/Low Fragmentor Voltage on TOF and Q-TOF High/Low Collision Energy on Q-TOF Pesticide library 700+ compounds with spectra) Forensics /Tox library (2720 compounds with spectra ) Qual Report Targets Find EICs for fragments on MS high channel Align EICs of fragments with parent EIC Extract Correlate qualified fragments with target Qualify and confirm fragments Export Quantify target with additional fragment ion confirmation Quant Report 63

minutes All Ions MS/MS Use and combine PCDL libraries with All Ions MS/MS. Export information and automatically create quant methods in seconds. Reduce processing time from one day to a matter of hours. 1400 Processing time 1200 1000 800 600 400 200 Quant Qual 0 Without All Ions With Allons 64

All Ions MS/MS Setup Turn on All Ions MS/MS using the current Formula Source PCDL Minimum Co-elution score 65

All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 66

All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 67

All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 68

All Ions MS/MS: Chromatographic Confirmation of Product Ions Overlaid low and high energy chromatograms Co-elution curves the precursor and product ions agree exactly on their apex! 69

New Compound Details View in Qual rev. B.06.00 New chromatogram and spectrum windows that show data from one compound only. Data belonging to one compound can be overlaid easily and quickly. 70

Quality Score for MFE 71

Molecular Formula Generator - Calculate Compound Formulas You can generate the molecular formula for each selected compound. First, find the Compounds, then use MFG. Example: Structure Elucidation of Degradation Products of the Antibiotic Drug Amoxicillin HO H H H O COOH O OH COOH HN H NH NH 2 N CH H 2 NH CH 3 O N 3 S NH NH S CH 3 S CH 3 H H H N O H O H O HO HO 1 2 3 H COOH CH 3 CH 3 1 Amoxicillin, 2 Amoxicillin penicillinoic acid, 3 Amoxicillin penilloic acid 72

Molecular Formula Generator 73

Molecular Formula Generator Algorithm Determine a mass in the compound to use for MFG: The program looks at clusters of ions and applies rules for isotopic abundance and mass spacing (mass accuracy and resolution are important to achieve this). Apply user knowledge of samples to limit the possible formula: Users fill out the Allowed Species dialog box with their knowledge of the chemistry of their samples. Rule out formulas that are chemically impossible (e.g. CH 7 ) Calculate probability scores for each candidate formula based on: Calculated vs. measured mass Calculated vs. measured abundance ratios Calculated vs. measured mass intervals of isotopes (isotope spacing) 74

Molecular Formula Generator Algorithm (cont.) Rank and display each candidate formula based on its probability score For calculations done in conjunction with MFE, calculate an abundance-weighted average cross score for all species (adducts, dimers, charge states) associated with a compound. These are all listed in the Compound List table 75

Molecular Formula Generator Algorithm MS/MS If MS/MS data are available, the algorithm uses it for greater confidence in formula generation: The algorithm generates tentative formulas for each MS/MS fragment (product ion). Precursor formulas with no related product ions are eliminated For a precursor formula to be valid, it must generate product ions that make sense Proposed precursor formulas are scored and ranked based on their fit with the product ions Algorithm uses coverage (explanation of how the precursor fragmented) and mass error of product ions A single score is provided that combines both MS and MS/MS data 76

Molecular Formula Generator Algorithm MS/MS Note the scores in the Compound List table below: Score (various) MS Score (MS-only) MS/MS (goodness-of-fit of product ions formulas to precursor formula) As of Qual rev. B.02.00, scores are absolute (Best is not fixed at 100) for comparison across formulae and samples. 77

Major Features of Qual B.06.00 All Ions MS/MS Compound Details View New Quality score for MFE Support for new tmrm files Enhanced Molecular Formula Generation New Find Compound Algorithm : Find by Integration Annotate fragment ions with fragment formula generation Save results faster Export format changes 111