Baltic Marine Environment Protection Commission

Similar documents
Baltic Marine Environment Protection Commission

Test Method: CPSC-CH-E

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Samples compliant with the WATER

Basic Digestion Principles

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

ICP-OES Application Note Number 35

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

IAEA-TECDOC-9SO. Sampling, storage

Prof. Dr. Biljana Škrbić, Jelena Živančev

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Elemental analysis of river sediment using the Agilent 4200 MP-AES

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Appendix: Laboratory Testing Methods

Analysis of domestic sludge using the Agilent 4200 MP-AES

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

PROFICIENCY TESTING: EXPERIENCES FROM CROATIA ON THE ISSUE OF HEAVY METALS DETERMINATION IN MARINE SEDIMENTS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Certificate of Analysis

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Sodium Chloride - Analytical Standard

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

2101 Atomic Spectroscopy

GB Translated English of Chinese Standard: GB

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

METALS IN WATER BATCH: MATERIAL. Description. Cu, Ni and. Quantity 5% (V/V). Use. the mark in. such a way. water. The are given in QC METAL HL2

Certificate of Analysis

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

PAR Method Method to 2.0 mg/l Pb TNTplus 850

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

ANALYSIS CERTIFICATE OF

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Results of the 18 th and 19 th Needle/Leaf Interlaboratory Comparison Tests

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Preparation of Food and Feed Samples for Metals Analysis

SECTION D.2 AMMONIA NITROGEN

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Opening the analytical black box: Insights into interferences, corrections, and data quality

Determination the elemental composition of soil samples

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

Sediment characteristics of Beaver Lake and implications for remediation; A Pilot Project.

Manual for Marine Monitoring in the COMBINE. General guidelines on quality assurance for monitoring in the Baltic Sea

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use.

Sources of Errors in Trace Element and Speciation Analysis

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Cadmium and lead content

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Handbook of Inductively Coupled Plasma Spectrometry

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

Sodium Chloride - Analytical Standard

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

high temp ( K) Chapter 20: Atomic Spectroscopy

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Transcription:

Baltic Marine Environment Protection Commission Working Group on the State of the Environment and Nature Conservation Copenhagen, Denmark, 22-26 October 2018 STATE & CONSERVATION 9-2018 Document title Guideline on the determination of heavy metals in sediment Code 3MA-3 Rev 1. Category DEC Agenda Item 3MA Development and implementation of Recommendations Submission date 29.10.2018 Submitted by Secretariat Reference This revised document contains the guidelines for the determination of heavy metals in sediment, as revised by STATE & CONSERVATION 9-2018. Page 1 of 6

Guideline for the determination of heavy metals in sediment 1. Introduction This Technical note provides advice on the analysis of heavy metals in total marine and coastal sediments and sieved fractions, including sampling and sample handling. The analysis of heavy metals in sediments basically includes digestion and detection by Graphite Furnace Atomic Absorption (GFAAS), flame atomization, ICP-ES or ICP-MS. All steps of the procedure are susceptible to insufficient recovery and contamination. Quality control measures are recommended in order to regularly monitor the performance of the method. These guidelines are intended to encourage and assist analytical chemists to critically review their methods and to improve their procedures and quality assurance measures, if necessary. These guidelines are not intended as complete laboratory manual. If necessary, guidance should be sought from specialized laboratories. Laboratories should demonstrate validity of each methodological step. Moreover, use of an alternative method, carried out concurrently to the routine procedure, is recommended for validation. The analyses should be carried out by experienced staff. Contracting parties should follow the HELCOM monitoring guideline but minor deviations from this are acceptable if the method achieves comparable results. Validation of the adopted method needs to be performed on the relevant matrix and concentration range e.g. by taking part in intercomparison studies or proficiency testing schemes. 2. Sampling and sample handling The major criterion for successful sediment sampling is to guarantee a fairly undisturbed sample stratification. Of particular interest is the undamaged surface of the sample. Reasonable results are obtained by the application of box corer devices or a multiple corer. Trend monitoring in sediments requires information about the current trace substance burden in the uppermost sediment layer (e.g., 0-1 cm). This first centimeter accumulates the deposits of the recent few years and thus is the object of the routine sediment analysis. In practice, apart from this kind of specialized environment where bioturbation and physical disturbance of sediment are negligible and undisturbed surface sediments can be sampled, it is recommended to sample the top layer of the sediment, from 1 to 5 cm depth, depending on the deposition rate (EU, 2010) Formatted: English (United States) Formatted: English (United States) Only if long-term time series (decades/centuries) of the trace substance burden of the deposit (or background concentration studies) are part of the investigations, the analysis of deeper sediment layers is required. Immediately after sampling, the first 0-1 cm of the core is removed and stored. If the water content is very high it is usually required to get replicates of the sample in order to obtain enough dry weight material for an analyses of a large number of metals. If the entire core is the object of the investigation and information on sedimentation rates is available, the thickness of core slices can be selected to represent certain time periods to achieve a specified statistical power for trend detection. In many cases dating will only be available after a core is separated in slices allowing the relevant slices to be selected for analysis. The sediment composition should be sufficiently constant over depth so that shifts in composition do not determine the concentration profile. If the sediment composition varies with depth, then normalisation of contaminant concentrations from the total samples <2 mm or sieved fraction is required (see Chapter 5 of Deleted: If the entire core is the object of the investigation, it is recommended to dissect the first 10 cm into five 2 cm layers. The deeper part should only be analyzed in distinct sections, which cover the ranges: 15 17 cm, 22 24 cm, and 29 31 cm (Perttilä and Brügmann, 1992). Deleted: Annex Page 2 of 6

this guideline). Pieces of glass or colourless polyethylene tools are recommended for the sectioning of the core. After each layer has been cut off, the tools should be changed and cleaned. The selected sediment layers (samples) should be placed in separate and clean glass or polyethylene (polypropylene/polystyrene) containers or nylon bags carefully labelled and pre-weighted. The label should contain at least the sample identification number, and the date and location of sampling. Commented [A1]: SE: It would be good to refer than to annex 5 in the same guideline to enhance clarity. Note: Reference Pertilää & Brügmann 1992 to be deleted Deleted:. The following procedure is recommended for cleaning the tools and containers for sediment sample handling prior to the sampling campaign. Wash by soaking for 2 3 days in diluted (10%) HNO 3, then rinse with high purity water. During the sampling campaign, the reused tools, the table, and corer components should be carefully cleaned by rinsing with seawater. The tools and containers must be stored dust-free when not in use. A comprehensive description of cleaning procedures for plastic and glass laboratory ware can be found in Annex B-12, Appendix 1 "Technical notes on the determination of trace metals (Cd, Pb, Cu, Co, Zn, Ni, Fe) including mercury in seawater" of these "Guidelines". The samples should be deep frozen as soon as possible after packing. At least immediate cooling in a fridge after sampling is recommended. Take note that freezing of a large bulk of containers should be avoided; the samples in the centre would take longer to cool and this may result in some loss of mercury. Once frozen, the samples can be stored at temperatures of 20ºC or below. 3. Sample pretreatment; contamination control Because trace metals are mostly associated with the fine sediment fraction, it is recommended to focus sampling on muddy sediments, consisting of a predominantly fine grain fraction of less than 63 μm. In case of uncertain grain composition of the sample or sandy sediments, it is recommended to pass the samples through a sieving procedure (OSPAR 2015), to separate a well defined <63µm fraction for further analysis. Be aware that sieving sampled sediments come with a risk of contamination due to the extra working step before analyzing the sample. A quantification of the fine grain fraction (<63µm) of the sediment sample by sieving or measurement with a particle laser provides valuable information to determine the sediment type. Furthermore, this information could be used as a normalization parameter. Prior to the instrumental detection, sediment samples must be digested. The removal of water from the frozen samples is recommended, preferably by freeze-drying. The freeze-drying can be performed directly on the frozen sediments and without change of the container; the loss of mercury is also thus avoided. The freeze-dried sediments can be then stored almost indefinitely. During freeze-drying, samples can (and should) be protected from cross-contamination (particles and vapours) by applying a lid with a small hole covered with filter-paper over the sample container. After drying, it needs to be secured that the sample is thoroughly homogenized before subsampling for metals analysis. To ensure proper homogenization the sediments could be carefully homogenized if needed, e.g., using a ball mill. For the complete digestion of marine sediments, a pressure wet ashing is recommended (e.g. Loring and Rantala, 1991). Since the rate of digestion and efficiency of acid decomposition increase substantially with elevated temperatures and pressure, the closed vessel techniques, using conventional heating or microwave energy, are applied preferably to open systems. Open systems should be checked thoroughly for loss of Hg. The most widely applied technique for sediment mineralization is at present microwave digestion with concentrated acids. Dependent on the matrix optimized compositions of nitric, perchloric and hydrofluoric acid are widely applied. An omission of hydrofluoric acid results in a partial digestion, which leaves the crystalline (SiO 2) matrix of the sediment sample untouched. A full digestion method, which is based on the application of a mixture of nitric and hydrofluoric acid, is described in Loring and Rantala (1990) or McCarthy and Ellis (1991). Al, Li, Fe and TOC are commonly used for normalization of the Page 3 of 6

results of analyses. More information about the application of normalization procedures can be found in Annex B16, OSPAR (2015) and Smedes et al. (2000). Further requirements to avoid losses of the determinand or to solve contamination problems are described by, e.g., Boutron (1990) and Schmidt and Gerwinski (1994). The availability of high purity reagents is a prerequisite for reliable determination of heavy metal concentrations. And the first order of priority is a sufficient supply of high purity water. For contamination control, a procedural blank (recommended in triplicate) has to be carried out throughout all the operational steps parallel to the samples. 4. Calibration For calibration purposes, single standard stock solutions, purchased from a qualified manufacturer or a multielement standard, can be used. Fresh standard stock solutions should be compared with the older standard solutions. Single or multielement standard solutions are prepared by dilution of the stock solution using dilute acid, as required. The concentrations of particular elements in a mixed standard stock solution can be matched in such a way as to produce a single series of working standard solutions for all elements analysed (with the exception of Al and Fe whose concentrations fall in a different range). All standard solutions have to be stored in polyethylene, borosilicate or quartz volumetric flasks. Standard solutions with lower concentrations, if prepared correctly and controlled in a QA system (checking of old versus new, and checking with standards from a different source), can be kept for a period no longer than one month. It must be mentioned that plastic materials used for the production of laboratoryware exhibit certain adsorptive or exchange properties. Hence, boundary-surface interactions can be very important when very dilute analytical solutions are handled. It is thus imperative that volumetric flasks, reagent vessels, pipette tips, etc., for handling sample solutions and low level reference or analyte solutions must never be used for transferring or processing stock solutions of analyte or concentrated reagents. The calibration procedure has to meet some basic criteria in order to give the best estimate of the true element concentration of the sample analysed: the concentrations of standards for the preparation of the calibration curve (function) should cover the range of concentrations as related to practical conditions; the mean of the range should be roughly equal to the expected analyte concentration in the sample; the required analytical precision should be known and achievable throughout the entire range of concentrations; the measured value (instrument signal) at the lower end of the range has to be significantly different from the procedural analytical blank; the chemical and physical properties of the calibration standards must closely resemble those of the sample under investigation, i.e., the difference in density between the standard and environmental sample should be minimized (this is of particular importance in flame atomic absorption determinations); as a general rule, the analysis of each batch of environmental samples should be accompanied by analysis of a certified reference material (CRM) or at least a laboratory reference material (LRM). 5. Instrumental determination Heavy metals appear in marine sediments in low concentrations, ranging from µg kg 1 to mg kg 1 (Szefer, 2002). Stoeppler (1991) provided a comprehensive review of the most frequently used techniques for quantitative analysis of metallic trace elements. Page 4 of 6

Instrumental determination of heavy metals in the acidic solution obtained is carried out depending on the instrument and manufacturer s specifications. In most cases, i.e., in most marine sediments, Cd and Pb can be determined by GFAAS (Graphite Furnace Atomic Absorption), while Cu, Zn, Cr, Ni, Mn, Al, and Fe can also be determined by the less sensitive flame atomization. Multielement methods with plasma atomization have become the standard for analysis of metals in later years (Larsen et al, 2011), as ICP-OES and ICP-MS have the ability to determine all elements in one go. ICP-OES is very robust and generally sensitive enough to cover the metal concentrations expected in sediments, perhaps except Cd, over a large concentration range. As the method is based on emission spectra for ionized metals, possible spectral overlap needs to be corrected, and it is recommended to measure at more than one wavelength if sensitivity allows for it. Both radial and axial view ICP-OES are now available, and have extended the linear range of the calibration to avoid dilution. Detection limits are usually between those of flame and graphite furnace AAS, but new developments are pushing the detection limits closer to the GFAAS limits. ICP-MS is currently state-of-the-art instrumentation for metal analysis, with the possibility to determine almost the entire periodic table at sub ng/l concentrations. Most routine instruments utilize a quadrupole mass spectrometer, so mass resolution is not high enough to avoid overlap of double charged elements or multi-element ions (mainly hydrides, oxides and hydroxides) formed in the plasma. The main concern is for the Ar interferences as the plasma is usually an argon plasma, overlapping with 75 As + as 37 Cl 40 Ar +, and of the Se masses. For As no alternative mass is available but for most other elements, measurement of two or more isotopes can be used for quantification. It is recommended to use a cell with a small gas flow (collision cell or dynamic reaction cell) of H 2, He, NH 4 or CH 4 to remove the polyatomic interference by collision or reaction with the gas in the cell, in combination with mas overlap correction formulas (e.g. de Boer (2000), USEPA 6020 or ISO 17294-2). To correct for changes in the nebulizer and cone system used to transport the ion beam from atmospheric pressure to vacuum in the MS detector, it is recommended to use internal standards of e.g. Ir, Rh, Ge or In. Some elements are prone to memory effects (particularly Hg) and needs extra precautions to avoid carry over effects (e.g. addition of HCl or Au to digest or rinse solution). For both ICP-OES and ICP-MS, modern instruments software includes all the tuning and correction formulas needed and described above to perform the analysis. High resolution ICP-MS can be used to avoid mass overlap corrections, but instruments are more expensive and often difficult to tune and maintain for routine laboratories. 6. Quality Assurance A number of measures should be taken to ensure sufficient quality of the analysis. Six main areas can be identified: 1. digestion efficiency; 2. calibrant and calibration; 3. system performance; 4. long-term stability; 5. internal standards; and 6. frequent participation in interlaboratory proficiency testing schemes (e.g. QUASIMEME two times a year, www.quasimeme.org). Field Code Changed Page 5 of 6

7. References Boutron, C.F. 1990. A clean laboratory for ultralow concentration heavy metal analysis. Fresenius Journal of Analytical Chemistry, 337: 482 491. De boarj.l.m. 2000. Real-time adjustment of ICP-MS elemental equations, J. Anal. At. Spectrom 9(5) 1157-1160 EU. 2010. Guidance Document No. 25. Guidance on chemical monitoring of sediment and biota under the water framework directive. DOI 10.2779/43586 ISO (2016) ISO 17294-2:2016 Water quality -- Application of inductively coupled plasma mass spectrometry (ICP-MS) -- Part 2: Determination of selected elements including uranium isotopes Larsen, M.M., Søndergaard, J., Asmund, G. Parmentier, K and Vermaerchke, P. (2011) Trace elements. In Chemical Marine Monitoring: Policy Framework and Analytical Trends, Quevauviller, P. Roose, P. And Verreet, G. John Wiley /Sons, Ltd. Loring, D.H. 1991. Normalisation of heavy metal data from estuarine and coastal sediments. ICES Journal of Marine Science, 48(1): 101 115. Loring, D.H., and Rantala, R.T. T.1990. Sediments and suspended particulate matter: Total and partial methods of digestion. ICES Techniques in Marine Environmental Sciences, No.9. 14 pp. Loring, D.H., and Rantala, R.T.T. 1991. Manual for the geochemical analyses of marine sediments and suspended particulate matter. Earth-Science Reviews, 32: 235 283. McCarthy H.T., and Ellis P.C. 1991. Comparison of microwave digestion with conventional wet ashing and dry ashing for analysis of lead, cadmium, chromium, copper and zinc in shellfish by flame atomic absorption spectroscopy. Journal of the Association of Official Analytical Chemists, 74: 566 569. OSPAR 2015. JAMP Guidelines for Monitoring Contaminants in Sediments. www.ospar.org Perttilä M., and Brügmann L. (eds.) 1992. Review of contaminants in Baltic sediments. ICES Cooperative Research Report, 180: 1 135. Smedes, F., Davies, I.M., Wells, D., Allan, A., and Besada, V. 2000. Interlaboratory study on sieving and normalisation of geographically different sediments. QUASH, round 5; Report, QUASH Project Office, FRS Marine Laboratory, PO BOX 101, Victoria Road, Aberdeen, AB119DB, UK. Schmidt D., and Gerwinski W. 1994. Design principles of clean laboratories for trace metal analysis. In ICES/HELCOM Workshop on Quality Assurance Procedures for the Baltic Monitoring Programme. Ed. by G. Topping and U. Harms. Baltic Sea Environment Proceedings, 58: 111 117. Stoeppler, M. 1991. Analytical chemistry of metals and metal compounds. In Metals and Their Compounds in the Environment, pp. 105 206. Ed. by E.Merian. VCH Weinheim. Szefer, P. 2002. Metals, metaloids and radionuclides in the Baltic Sea Ecosystem. Trace Metals in the Environment 5, Elsevier, Amsterdam-London-New York-Oxford-Paris-Shannon-Tokyo.752 pp. USEPA (1994) Method 6020, Environmental protection Agency, Washington, DC. Page 6 of 6