REPORT NO. : CRSSA/0032-1/16 PAGE : 1 of Hitachi Chemical (Selangor) Sdn. Bhd. The following merchandise was (were) submitted and identified by the client as: Sample Receiving Date : 07/01/2016 Testing Period : 07/01/2016 to 13/01/2016 : Please see the next page Analysts : Foong Cheng Chee & Shirley Then t +6(03) 121 2320 f +6 (03) 121 9082 www.sgs.com
REPORT NO. : CRSSA/0032-1/16 PAGE : 2 of Test Item (s) : Unit Method Instrument MDL Results Limit Chromium VI (Cr6+) IEC 62321 : 2008 Annex C UV Vis - Spectrophotometer 2 1000 Cadmium (Cd) IEC 62321- : 2013 ICP OES 2 100 Mercury (Hg) IEC 62321-4 : 2013 ICP OES 2 1000 Lead (Pb) IEC 62321- : 2013 ICP OES 2 1000 NOTE: (a) = Not detected (<MDL) (b) = mg/kg (c) MDL= Method Detection Limit (d) Testing based on original basis Analyst: Foong Cheng Chee t +6(03) 121 2320 f +6 (03) 121 9082 www.sgs.com
REPORT NO. : CRSSA/0032-1/16 PAGE : 3 of Test Item (s) : Unit Method Instrument MDL Result Limit PBBs (Polybrominated Biphenyls) Monobromo Biphenyl Dibromo Biphenyl Tribromo Biphenyl Tetrabromo Biphenyl Pentabromo Biphenyl Hexabromo Biphenyl Heptabromo Biphenyl Octabromo Biphenyl Nonabromo Biphenyl Decabromo Biphenyl PBDEs (Polybrominated Diphenyl ethers) as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 1000 Monobromo Diphenyl Ether Dibromo Diphenyl Ether Tribromo Diphenyl Ether Tetrabromo Diphenyl Ether Pentabromo Diphenyl Ether Hexabromo Diphenyl Ether Heptabromo Diphenyl Ether Octabromo Diphenyl Ether Nonabromo Diphenyl Ether Decabromo Diphenyl Ether as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 as per IEC 62321-6: 201 1000 NOTE: (a) = Not detected (<MDL) (b) MDL = Method Detection Limit (c) Testing based on original basis Analyst : Shirley Then t +6(03) 121 2320 f +6 (03) 121 9082 www.sgs.com
REPORT NO. : CRSSA/0032-1/16 PAGE : 4 of Hitachi Chemical (Selangor) Sdn. Bhd. CRSSA/0032-1/16 t +6(03) 121 2320 f +6 (03) 121 9082 www.sgs.com
1. DETERMINATION OF CADMIUM CONTENT BY IEC 62321-2013 Weight sample (0.2-0.g) into digestion vessel 3. DETERMINATION OF MERCURY CONTENT BY IEC 62321-4 2013 Weight sample (0.1-0.g) into digestion vessel REPORT NO. : CRSSA/0032-1/16 PAGE : of 2. DETERMINATION OF LEAD CONTENT BY IEC 62321-2013 Weight sample (0.2-0.g) into digestion vessel 4. DETERMINATION OF HEXAVALENT CHROMIUM BY IEC 62321 2008 Add colour-developing reagent Acidify with H 2SO 4 Let stand for -10 min Analyses by UV- Spectrophotometer (40 nm). DETERMINATION OF PBB/PBDE WITH GC-MS BY IEC 62321-6 201 Weight sample (0.-4.0g) into extraction thimble Soxhlet Extraction with Toluene Filter through 0.4 um membrane filter Analyses by GC-MS (with appropriate dilution) t +6(03) 121 2320 f +6 (03) 121 9082 www.sgs.com