Low Background Counting At SNOLAB

Similar documents
Ultra-Low Background Counting and Assay Studies At SNOLAB

Ultra-Low Background Measurement Capabilities At SNOLAB

Low Background Physics at SNOLAB

Backgrounds in PICO. Eric Vázquez Jáuregui SNOLAB. AARM Meeting Fermilab; Batavia IL, USA; March 19, 2014

Select Assay Capabilities at PNNL

Studies of the XENON100 Electromagnetic Background

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

Radiometric Measurements of Environmental Radioactivity

Radon Emanation Testing for DRIFT

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

Leaching Studies for the SNO+ Experiment

Study well-shaped germanium detectors for lowbackground

UCLA Dark Matter 2014 Symposium. Origins and Distributions of the Backgrounds. 15 min

arxiv: v1 [physics.ins-det] 26 May 2015

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Outline. Dark Matter Physics at SNOLAB: And Future Prospects. Overview of SNOLAB DarkMatter Program. Status of Current Experiments

First tests of the big volume ultra low background gamma spectrometer

Distillation purification and radon assay of liquid xenon

Renewed whole-body counting chamber in STUK

Radiometric Measurements of Environmental Radioactivity Beta Counting, Alpha and Gamma Spectrometry

A coincidence method of thorium measurement

World Underground Labs: Status and Plans. Mark Chen Queen s University ICFA Seminar October 29, 2008

cryogenic calorimeter with particle identification for double beta decay search

HEROICA: a test facility for the characterization of BEGe detectors for the GERDA experiment

The XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University

Low level radioactivity assays with HPGe detectors

HPGe detector fabrication at CANBERRA. V. Marian, M.O. Lampert, B. Pirard, P. Quirin, J. Flamanc CANBERRA Specialty Detectors (Lingolsheim)

Walter C. Pettus University of Wisconsin Madison. Weak Interactions Discussion Group Yale Physics 21 Oct 2013

European Project Metrology for Radioactive Waste Management

Quality Assurance. Purity control. Polycrystalline Ingots

Simulations, backgrounds, and uncertainties in PICO-2L. Alan Robinson May 20, 2015 AARM, Rapid City South Dakota

Status of the GERDA experiment

Status of KIMS-NaI experiment

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

COUPP: Bubble Chambers for Dark Matter Detection

arxiv: v2 [astro-ph.im] 10 Jan 2012

THE NEXT EXPERIMENT FOR NEUTRINOLESS DOUBLE BETA DECAY SEARCHES ANDER SIMÓN ESTÉVEZ ON BEHALF OF THE NEXT COLLABORATION

Gamma-Spectrum Generator

Gamma background measurements in the Boulby Underground Laboratory

cosmic rays plus interaction with neutrons from fission and (α,n) reactions interaction with cosmic muons and neutrons direct activation

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik

Current status of LUX Dark Matter Experiment

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

A cryogenic detector for 222 Rn

COUPP500: a 500kg Bubble Chamber for Dark Matter Detection

Background measurements in the underground labs: Gran Sasso, Modane and Boulby

Recent Progress from the DEAP-3600 Dark Matter Direct Detection Experiment

Testing DAMA/LIBRA signal with ANAIS-112

Identification of Naturally Occurring Radioactive Material in Sand

A Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants.

Walter C. Pettus on behalf of the DM- ICE collaboration University of Wisconsin Madison. APS April Meeting Session D11: Dark Matter II 13 April 2013

Backgrounds and Sensitivity Expectations for XENON100

The Search for Dark Matter with the XENON Experiment

Cosmogenic and primordial radioisotopes in copper bricks shortly exposed to cosmic rays

arxiv:nucl-ex/ v2 21 Jul 2005

GERDA Meeting, September 2009, LNGS. News from Low-Level-Lab: Attempt to Reduce Neutron Background at Shallow Depths

The MAJORANA DEMONSTRATOR Assay Program and Capabilities Necessary to Support a Future 1 Tonne Scale Experiemnt. E.W. Hoppe

Low Background NAA: A powerful tool for Physics of Rare Experiments and Environmental Sciences

Cosmogenic background for the GERDA experiment. Luciano Pandola INFN, Laboratori del Gran Sasso, Italy

Background Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011

The Sudbury Neutrino Observatory (SNO) and the new SNOLAB

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Background Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH

ARMUG New CAM Developments. Arran Morgan MSc Physicist

Measurements of natural radioactivity in the salt cavern of the Polkowice Sieroszowice copper mine

Waveform Analysis for DM-Ice17. Zachary Pierpoint University of Wisconsin - Madison October 21, 2013 Yale Weak Interactions Discussions Group

The Effects of Exposing UltraLo-1800 Samples to Room Air

Water Purification in Borexino

GERDA experiment A search for neutrinoless double beta decay. Roberto Santorelli (Physik-Institut der Universität Zürich)

arxiv: v1 [nucl-ex] 20 Dec 2008

The need for a large-area low emissivity alpha particle standard

Radioactivity measurements for the ERMES project at the STELLA facility

Dark matter search with the SABRE experiment

Sensitivity and Backgrounds of the LUX Dark Matter Search

Background simulations and shielding calculations

Rn assay and distillation purification

Status of CUORE and Results from CUORICINO. SERGIO DI DOMIZIO UNIVERSITÀ & INFN GENOVA On behalf of the CUORE Collaboration

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

Chem 481 Lecture Material 3/20/09

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

SOURCES of RADIOACTIVITY

24th Seismic Research Review Nuclear Explosion Monitoring: Innovation and Integration

Neutrino Physics with SNO+ Freija Descamps for the SNO+ collaboration

I. Abstract. Majorana nature by searching for neutrinoless double-beta decay (0υββ). Backgrounds from alpha

Beta Screening Options

Basic hands-on gamma calibration for low activity environmental levels

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

The Dortmund Low Background Facility Low-Background Gamma Ray Spectrometry with an Artificial Overburden

Bubble Chambers for Direct Dark Matter Searches in COUPP

Preparatory experiments for cold-neutron induced fission studies at IKI

ANAIS: Status and prospects

Background and sensitivity predictions for XENON1T

Shielding Strategies. Karl Tasso Knöpfle MPI Kernphysik, Heidelberg

Produc'on and coun'ng of uncontained sources in SNO. Simon JM Peeters

The Best Gamma-Ray Detector

arxiv: v2 [physics.ins-det] 15 Nov 2017

Transcription:

Low Background Counting At SNOLAB Ian Lawson Collaboration Meeting Minneapolis, Minnesota, June 22-23, 212 1

Outline SNOLAB and description of the SNOLAB Low Background Gamma Counting System Other material screening and counting systems Existing SNOLAB low background data repository Status of new Canberra gamma counting systems New low background underground lab Summary 2

SNOLAB Surface Facility 2km overburden (6mwe) Underground Laboratory 3m

SNOLAB DEAP-36 MINICLEAN Low Background Counting Drift PGT HPGe Cube Hall COUPP-4 DEAP-1 DAMIC HALO Cryopit COUPP-6 Ladder Labs PICASSO Emanation Chamber SuperCDMS SNO+ SNO Cavern Personnel facilities XRF Canberra HPGe Utility Area 4

SNOLAB Low Background Counting System Establishment of the Low Background Gamma Facility @ SNOLAB in 25. The counter has run continuously since then. Motivation Survey materials for new, existing and proposed experiments (to be) located @ SNOLAB, such as SNO, SNO+, DEAP1, miniclean, PICASSO, EXO,... Have also assayed materials for DM-ICE and DRIFT. Constructed @ SNOLAB from an HPGe detector and its associated shielding located underground at 46 ft level since 1997. Counter manufactured by PGT. Endcap diameter 83 mm. Relative Efficiency is 55% wrt a 7.62 cm dia x 7.62 cm NaI(Tl) detector. Resolution 1.8 kev FWHM. Shielding 2 inches Cu + 8 inches Pb Nitrogen purge at 2L/min to keep radon out. 5

SNOLAB PGT HPGe Counter 6

Uranium Decay Chain 7

Thorium Decay Chain 8

Other Interesting Isotopes Usually Present: 4K 4 146.83 kev 137 Cs 661.66 kev e+ K 4 137 Cs 137m Ba 137 Ba γ 146.8 kev 6Co 6 Co β 1173.2 kev 1332.5 kev 235U Ar β Γ 661.6 kev 143.76 kev 163.33 kev 185.22 kev 25.31 kev γ 1173 kev 6 γ 1332 kev Ni 235 U α 231 Th 4 γ s Occasionally Present: 54 Mn at 834.85 kev Observed in Stainless Steel 7 Be at 477.6 kev 138 La and 176Lu Observed in Carbon based materials, due to neutron activation, samples are particularly affected after long flights. Observed in rare earth samples such as Nd or Gd. 9

Unshielded and Shielded Spectra No Shielding Shielding In Place 1

Background Comparison Unshielded Versus Shielded Activity Isotope 4 Activity Shielded Crystal (Bq) U 7.11 ± 1.64.128 ±.16 Th 36.99 ± 1.21.141 ±.16 238 232 Activity Unshielded Crystal(Bq) K 137 6 1723.33 ± 88.2.189 ±.17 Cs 1. ±.15.2 ±.2 Co.23 ±.52.36 ±.5 Unshielded Measurements done by Yoram Nir-EL 11

PGT HPGe Detector Sensitivity Isotope 4 Typical for Earth's Crust 1 ppb U 81 ppb 12 mbq/kg ~ 1 mbq/kg ~.1 ppb 37 Bq/kg 3 ppm Th 246 ppb 4.1 mbq/kg ~ 1.5 mbq/kg ~.3 ppb 45 Bq/kg 11 ppm.31 mbq/kg ~ 21 mbq/kg ~.7 ppm 8 Bq/kg 2.5 % 238 232 Sensitivity for Standard Size Samples 1 Bq/kg K 32 ppm Better sensitivities have been achieved for specialized very large samples combined with an extremely long counting period: 238 U:.9 ppb, 232 Th:.2 ppb, 4 K: 87 ppb 12

Calibration Spectrum 57 Co 139 Ce 137 Cs 54 Mn 85 Sr 88 Y 65 Zn 88 Y 133 Ba 89 Kr 88 Y New calibration standards are being proposed which have much longer half-lives to allow the calibration sample to be used for several years unlike most commercial multigamma calibration samples. Would be used to cross-calibrate PGT and Canberra detectors. 13

Detector Efficiency From Mixed Calibration Sample Plot by James Loach The efficiency is scaled to individual samples using GEANT 4.9.4 which takes into account the sample components, to account for the density difference between the calibration source and the sample, and the sample geometry. 14

Typical Stainless Steel Spectrum 214 Pb 6 28 Tl Co 214 Bi 28 Tl 15

Typical Efficiency Correction Efficiency correction for steel sample. Use GEANT4.9.4, simulate detector with 1 million events at each energy. Extrapolate between energy bins with a polynomial fit..1 1. Energy (MeV) 16

Electrostatic Counting System Measures 222Rn, 224Ra and 226Ra levels. Sensitivity Levels are: 222 Rn: 1-14 gu/g 224 Ra: 1-15 gth/g 226 Ra: 1-16 gu/g Work is ongoing to improve sensitivity even further. 9 counters located at SNOLAB, 1 on loan to LBL, 1 on loan to U of A, 1 remains at U. of Guelph 17

Alpha Beta (Bi-Po) Counting System Currently located at the SNOLAB hot lab at LU so that spike sources can be measured. Sensitivity for 238U and 232 Th is ~ 1 mbq assuming that the chains are in equilibrium. 18

Material Screening Radon Emanation Chambers Used extensively for counting materials used in the SNO experiment. sensitivity ~5 decays per day. ICP-MS Association with facility at NRC (National Research Council) ICP-MS facility in Ottawa and with GeoLabs in Sudbury. NRC facility can be tuned to maximize sensitivity to U and Th at sub ppt levels. K limits to < 1 ppb. 19

Measurements To Date For Each Experiment Experiment 26 27 28 29 21 211 212 Total (-Jun 17) SNO 2 7 2 11 SNO+ 2 18 14 15 35 1 85 SNOLAB 7 3 9 6 1 35 EXO 1 1 2 1 5 MiniCLEAN 5 1 9 18 8 3 2 46 DEAP 8 8 12 1 8 15 2 63 HALO 2 3 1 1 7 PICASSO 1 1 4 3 9 DM-ICE / DRIFT -- -- -- -- 9 9 4 22 COUPP -- -- -- -- 1 15 8 24 Total 24 23 43 49 34 85 28 296 Calibrations &Tests 3 34 14 9 4 3 6 1 Samples in Detector Queue: - 19, which means up to 19 weeks or more of counting time! - the queue keeps getting longer, so the new counters are very important. 2

SNOLAB Data Repository 21

SNOLAB Data Repository SNOLAB maintains a database in a spreadsheet format for each experiment. The data is shown in units of mbq/kg or pp(b or m). The table shows data from the standard gamma searches:. 238 235 232 4 137 6 U, U, Th, K Cs, Co. While searching for the above gammas, we also search for any other peaks in the spectrum between 1 kev and 28 kev, For example, 54Mn is usually observed in steel. These are also included in the spreadsheet for each sample. The database is available to all SNOLAB users and can be made available to others upon request as it is password protected, contact Ian.Lawson@snolab.ca or Bruce.Cleveland@snolab.ca. 22

Future Low Background Counting At SNOLAB Two new low background high purity Ge Counters were ordered from Canberra One counter is a p-type coaxial detector and the other is a well detector. Canberra also supplied a specially built shield for the well detector. However, the well detector would not fit in the supplied shielding setup as the base of the well detector was too large for the copper disks and the vacuum tube connecting the dewar with the detector was too short for the shielding thickness. The well detector was sent back to Canberra to be rebuilt to fit the shielding, it has not been returned to SNOLAB yet. The shielding was slightly modified to allow the coax detector to fit so that the coax detector could be tested. 24

Future Low Background Counting At SNOLAB The well detector shielding was slightly modified to allow the coax detector to fit so that the coax detector could be tested. The coax detector was then run inside the well detector shielding to characterize the backgrounds in the hope the detector has backgrounds less than the PGT detector, which we used as the basis for maximum background requirements. coax well However, it was determined that the coax detector is anything but low in backgrounds. It has substantial amounts of 232Th and 235U, the other backgrounds are similar to those observed from the PGT counter. 25

Future Low Background Counting At SNOLAB The background levels for a true ultralow background detector should be no more than 1 counts/year from U and Th chain events. coax The activities present are: 228 228 238 4 Th progeny at 3 counts/day well Ra progeny at 3 counts/day U progeny at 5-6 counts/day, although below 226Ra the rate is only about 5 counts/day. K at 18 counts/day Canberra has sent SNOLAB many components to determine where this background is coming from, but so far there is no smoking gun. 26

SNOLAB Low Background Laboratory (under construction) A new dedicated space is being constructed at SNOLAB for a low background lab located in the South Drift (former refuge station). This drift is somewhat isolated from other drifts and is inaccessible to large equipment (fork lift). This will help reduce micro-seismic noise which can effect Ge detectors. South Drift Increased air flow and perhaps other radon reduction techniques will be used. It is known that the compressed air from surface has substantially less radon than the lab air and can be used to reduce radon levels from 135-15 Bq/m3 to 1-5 Bq/m3. Space can accommodate 3-5 Ge detectors, XRF, radon emanation chamber and have room for other types of counters which would benefit from low-cosmic ray background. 27

Summary SNOLAB PGT HPGe low background counting system has run continuously for the past since 25 and has counted 296 samples so far. Counting queue in unusually long at 19 samples, this sometimes limits when samples can be counted in a timely manner. The counter(s) is available for all SNOLAB experiments and can be made available to non-snolab experiments upon request. Two new Canberra Ge detectors were delivered to SNOLAB, but are now being refurbished since they are not ultra-low background as expected. The new counters should allow much higher sensitivity, effort underway to ensure all materials are low background. The well detector will be used for very specialized small samples such as vapourized acrylic. Specialized counting can be done using the ESC or Alpha-Beta Counters and materials can be emanated for Radon. New low background counting lab is being constructed at SNOLAB, final preparations are now underway. 28