Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Similar documents
Thermo Scientific. Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

anion-exchange column

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

columns IonPac SCS 1 Silica Cation Separator

Determination of trace anions in concentrated hydrofluoric acid

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Utility of the Charge Detector in Ion Chromatography Applications

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

for IonPac AG11-HC IonPac AS11-HC

Thermo Scientific Dionex eluent suppressors for ion chromatography

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

suppressors Eluent Suppressors for Ion Chromatography

Inline sample preparation for the determination of anions in sodium hydroxide

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Overcoming Challenging Matrices in Ion Chromatography

Expanded capabilities in ammonium and amine detection

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

suppressors SRS -ULTRA Self-Regenerating Suppressor

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

The determination of trace anions in concentrated phosphoric acid

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography

High-Performance Chromatography Superior isocratic separation of

Determination of Adsorbable Organic Halogen in Wastewater

groups I and II cations, amines, divalent transition metals

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Monitoring Protein PEGylation with Ion Exchange Chromatography

Determination of Methylamine in Drug Products

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

The Determination of Trace Anions in Concentrated Phosphoric Acid

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of Trace Anions in Organic Solvents

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

IC Columns Introduction

Determination of trace anions in high-nitrate matrices by ion chromatography

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Sample Preparation for Ion Chromatography

IC5000 Ion Chromatography System

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

IonPac Trace Cation Concentrator

Determination of Monochloroacetic Acid in Carbocisteine

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Data Pack. Ion Chromatography Methods. June 2009

ION CHROMATOGRAPHY SYSTEM S 150

Determination of trace anions in concentrated glycolic acid

HILIC Method Development in a Few Simple Steps

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Determination of urea in ultrapure water by IC-MS/MS

The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

ProPac WCX-10 Columns

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts by Ion Chromatography

Transcription:

Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for the analysis of oxyhalides and the common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, chlorate, bromide, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices. The key application for the Dionex IonPac AS anion-exchange column is determination of trace bromate in drinking water matrices using an isocratic carbonate/bicarbonate eluent with suppressed conductivity detection. The Dionex IonPac AS column can be used in combination with the Thermo Scientific Dionex Eluent Generators and the Thermo Scientific Dionex Electrolytic ph Modifier (EPM), which automatically produce potassium carbonate/bicarbonate eluents from water. Determination of Trace Concentrations of Bromate Using the Dionex IonPac AS Column with a Large-Loop Injection. Column: Dionex IonPac AG/AS ( mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, Thermo Scientific Dionex ASRS ULTRA II mm Anion Self-Regenerating Suppressor, Thermo Scientific Dionex AutoSuppression. device, external water mode. Fluoride.. Chlorite.. Bromate.. Chloride. Nitrite.. Chlorate.. Bromide.. Nitrate. Carbonate. Phosphate.. Sulfate Meets Regulatory Requirements The Dionex IonPac AS column meets the performance requirements specified in U.S. EPA Methods. and. for the determination of oxyhalides produced as byproducts in disinfection of drinking water. The selectivity of the Dionex IonPac AS column ensures that bromate, a toxic byproduct in ozone disinfection, can be quantified at low μg/l concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate. The Dionex IonPac AS column allows the analysis of most drinking water, disinfected with ozone, without the use of sample pretreatment or preconcentration. Solvent compatibility permits easy column cleanup after the analysis of samples with hydrophobic components. The Dionex IonPac AS column is available in mm, mm and. mm i.d. formats.

Superior Chromatographic Performance Recommended carbonate based anion-exchange column for trace bromate in drinking water matrices. Optimized isocratic carbonate/bicarbonate eluent for the separation of oxyhalides and inorganic anions in a variety of sample matrices. Carbonate peak well resolved from common inorganic anions and oxyhalides. Meets performance requirements specified in U.S. EPA Methods. and.. Ideal alternative for Dionex IonPac AS-HC column oxyhalide and inorganic anion applications. Simplified Reagent-Free Ion Chromatography (RFIC ) system operation provided by Dionex Eluent Generators and Dionex EPM, which require only a deionized water source to produce potassium carbonate/bicarbonate eluent. Simple, accurate eluent preparations with the Dionex IonPac AS Eluent Concentrate just dilute in deionized water and start operation. Eluent suppression using the Thermo Scientific Dionex AERS Anion Electrolytically Regenerated Suppressor or Thermo Scientific Dionex ACES Anion Capillary Electrolytic Suppressor technology provides RFIC operation with low backgrounds and enhanced analyte sensitivity. High-capacity: μeq/col. ( mm column). Operate at ambient or elevated temperatures. Column selectivity is optimized for a C operating temperature to ensure reproducible retention times in all environmental conditions. Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or for effective column cleanup. Available in standard bore, microbore and capillary formats supporting flow rates from. ml/min to µl/min. High Efficiency Particle Structure The Dionex IonPac AS column was developed using a unique polymer bonding technology. The stationary phase consists of a novel hyper-branched anion-exchange condensation polymer, electrostatically attached to the surface of a wide-pore polymeric substrate. The substrate is surface-sulfonated in exactly the same manner as is common in Thermo Scientific Dionex latex coated anion-exchange materials. However, in this anion-exchange resin, alternating treatments of epoxy monomer and amines produce a coating which is grown directly off the substrate surface as illustrated in Figure. Resin capacity is controlled through the number of alternating coating cycles. The Dionex IonPac AS column uses a high-capacity resin ( μeg/ mm column) with optimized selectivity for the oxyhalides and common inorganic anions in diverse sample matrices. S Economical Capillary Operation The Dionex IonPac AS column is available in the. mm i.d. format for capillary operation to offer the advantage of reduced operating costs. Ideal for limited sample volumes due to higher mass sensitivity. One hundred fold reduction in eluent consumption and waste disposal. mm applications can be directly transferred to the. mm format by reducing flow rate by one hundred fold. Figure is an example of the separation of inorganic anions and oxyhalides using the Dionex IonPac AS Capillary column. Determination of Oxyhalides and Inorganic Anions in Diverse Sample Matrices The Dionex IonPac AS column is designed for the separation of oxyhalides and the common inorganic anions in a variety of sample matrices. These analytes can easily be separated in approximately min using an isocratic carbonate/bicarbonate eluent coupled with suppressed conductivity detection as shown in Figure. Column: Dionex IonPac AG/AS (. mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate: µl/min Inj. Volume:. µl Detection: Suppressed conductivity, Dionex ACES Suppressor, recycle mode. Fluoride.. Chlorite.. Bromate.. Chloride.. Nitrite.. Chlorate.. Bromide.. Nitrate.. Phosphate. Sulfate. Figure. Determination of oxyhalides and inorganic anions using the Dionex IonPac AS Capillary column. Conceptual Illustration of Surface Modification Column: Dionex IonPac AG/AS ( mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl ULTRA II mm Suppressor, Dionex AutoSuppression device, recycle mode Figure. Structure of a Dionex IonPac AS packing particle.. Fluoride. Chlorite. Bromate. Chloride. Nitrite. Chlorate. Bromide. Nitrate. Phosphate. Sulfate Figure. Determination of oxyhalides and inorganic anions using the Dionex IonPac AS column.

Figure shows the separation of the oxyhalides and the common inorganic anions in a municipal drinking water sample. The high-capacity and selectivity allows for the separation of nitrate from carbonate even in the presence of high concentrations (over mg/l) of carbonate. Figure shows the separation of oxyhalides and common inorganic anions in a different municipal drinking water sample using the Dionex IonPac AS Capillary column. This sample was spiked with the surrogates malonate and succinate which are well resolved from the other anions. Column: Dionex IonPac AG/AS ( mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl ULTRA II mm Suppressor, Dionex AutoSuppression device, external water mode.. Fluoride.. Formate NQ. Chlorite.. Chloride.. Unknown NQ. Nitrite.. Unknown NQ. Chlorate.. Bromide.. Nitrate.. Carbonate NQ. Phosphate.. Sulfate.. Unknown NQ NQ: Not Quantified. Figure. Determination of oxyhalides and inorganic anions in a municipal drinking water sample using the Dionex IonPac AS column.. Column: Dionex IonPac AG/AS (. mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate: µl/min Inj. Volume: µl Detection: Suppressed conductivity, Dionex ACES Suppressor, recycle mode -.. Fluoride.. Formate NQ. Chlorite.. Chloride.. Chlorate.. Nitrate.. Phosphate <.. Sulfate.. Malonate.. Succinate.. Oxalate NQ Figure. Separation of oxyhalides, common inorganic anions and surrogate anions in municipal drinking water using the Dionex IonPac AS Capillary column.

Figure shows the separation of inorganic anions, oxyhalides, and organic acids in a chemical plant wastewater sample. Low levels of inorganic anions can easily be determined even in the presence of high levels of sulfate, chlorate, acetate, and formate. Figure shows the analysis of a different wastewater sample using the Dionex IonPac AS Capillary column. Low levels of fluoride, bromate, chlorate and bromide are easily determined in the presence of relatively high levels of chloride, nitrate and sulfate. Column: Dionex IonPac AG/AS ( mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume:. µl ULTRA II mm Suppressor, Dionex AutoSuppression device, external water mode.. Acetate.. Formate.. Chloride.. Nitrite.. Chlorate.. Nitrate.. Phosphate.. Sulfate.. Unknown NQ NQ: Not Quantified. Figure. Separation of inorganic anions, oxyhalides, and organic acids in a chemical wastewater sample using the Dionex IonPac AS column... Column: Dionex IonPac AG/AS (. mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate: µl/min Inj. Volume:. µl Detection: Suppressed conductivity, Dionex ACES Suppressor, recycle mode. Fluoride.. Formate NQ. Chlorite <.. Bromate.. Chloride.. Nitrite <.. Chlorate.. Bromide.. Nitrate.. Phosphate.. Sulfate. Figure. Separation of inorganic anions and oxyhalides in a wastewater sample using the Dionex IonPac AS Capillary column.

Determination of Trace Bromate in Drinking Water Matrices The high-capacity Dionex IonPac AS column can easily determine bromate at low μg/l concentrations in drinking water matrices. Bromate, a disinfection byproduct of the ozonation disinfection process for drinking water, has been cited by the U.S. EPA and the World Health Organization as a potential carcinogen, even at low μg/l concentrations. Treatment plants that use ozone for disinfection are required to monitor bromate, with a MCL of μg/l, plus the common inorganic anions. The Dionex IonPac AS column allows the analysis of most drinking water, disinfected with ozone, without the use of sample pretreatment or preconcentration. This method uses a large-loop injection with an isocratic carbonate/bicarbonate eluent coupled with suppressed conductivity detection as shown in Figure. Figure shows the analysis of trace level bromate in a simulated drinking water sample using the Dionex IonPac AS Capillary column. The injection volume was scaled down to µl simulating the large-loop injection on the standard bore column. Column: Dionex IonPac AG/AS ( mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl ULTRA II mm Suppressor, Dionex AutoSuppression device, recycle mode... Fluoride.. Chlorite.. Bromate.. Chloride. Nitrite.. Chlorate.. Bromide.. Nitrate. Carbonate. Phosphate.. Sulfate Figure. Determination of trace concentrations of bromate using the Dionex IonPac AS column with a large-loop injection.. Column: Dionex IonPac AG/AS (. mm) Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate: µl/min Inj. Volume: µl Detection: Suppressed conductivity, Dionex ACES Suppressor, recycle mode -.. Fluoride.. Acetate NQ. Formate NQ. Chlorite.. Bromate.. Chloride.. Nitrite.. Chlorate.. Bromide.. Nitrate.. Carbonate.. Phosphate.. Sulfate. Figure. The analysis of trace bromate in a simulated drinking water sample using a large-loop injection on the Dionex IonPac AS Capillary column.

Extended Application Capabilities The unique selectivity and high-capacity of the Dionex IonPac AS column make it an ideal column for method development of specialized anion applications. The Dionex IonPac AS column provides excellent separation of a variety of environmental anions including inorganic anions, oxyhalides, oxyanions, and organic acids using potassium hydroxide eluent. With a hydroxide gradient, these analytes are easily separated in less than min as shown in Figure. Figure shows the gradient separation of the same analytes using the Dionex IonPac AS Capillary column. Column: Dionex IonPac AG/AS ( mm) Eluent: Potassium hydroxide: mm from to min, mm from to min, mm from to min. Fluoride. Acetate. Butyrate. Formate Eluent Source: Thermo Scientific Dionex EGC II KOH Cartridge with Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column. Chlorite. Bromate. Chloride. Nitrite. Chlorate Flow Rate:. ml/min. Bromide Inj. Volume: µl. Nitrate ULTRA II mm Suppressor, Dionex AutoSuppression device, recycle mode. Carbonate. Sulfate. Selenate. Oxalate. Phthalate. Phosphate. Chromate. Iodide. Arsenate. Citrate. Thiocyanate. Perchlorate - Figure. Anion separation including inorganic anions, organic acids, oxyanions, and oxyhalides using the Dionex IonPac AS column, using a potassium hydroxide eluent delivered by an eluent generator. Column: Dionex IonPac AG/AS (. mm) Eluent: Potassium hydroxide:. Fluoride. mm KOH from to min,. Acetate. mm KOH from to min,. Butyrate. mm KOH from to min. Formate. Eluent Source: Dionex EGC KOH cartridge. Chlorite.. Bromate. Flow Rate: µl /min. Chloride. Inj. Volume:. µl. Nitrite. Detection: Suppressed conductivity, Dionex ACES. Chlorate. Suppressor, recycle mode. Bromide.. Nitrate.. Carbonate.. Sulfate.. Selenate.. Oxalate.. Phthalate.. Phosphate.. Chromate.. Iodide.. Arsenate.. Citrate.. Thiocyanate.. Perchlorate. Figure. Separation of a wide variety of environmental anions using the Dionex IonPac AS Capillary column.

System Requirements The Dionex IonPac AS Capillary column is recommended for use with the Thermo Scientific Dionex ICS- + or Thermo Scientific Dionex ICS- Capillary HPIC system. The Dionex IonPac AS Analytical column is recommended for use with the Dionex ICS- or Dionex ICS- + RFIC system equipped with an eluent generator and EPM. The Dionex IonPac AS Analytical column can also be used with older Dionex IC systems equipped with an eluent generator and EPM or a Thermo Scientific Dionex RFC- Reagent-Free Controller. The eluent generator is used to automatically produce carbonate and bicarbonate eluents from deionized water. Suppressor Recommendations For optimum ease-of-use and performance, the Dionex IonPac AS column should be used with the Dionex AERS Suppressor or the Dionex ACES Suppressor. Concentrator Columns For concentrator work with a mm or mm Dionex IonPac AS column, use the: Dionex IonPac AG guard column; Ultratrace Anion Concentrator Columns (Dionex IonPac UTAC-ULP, UTAC-XLP, UTAC-ULP, or UTAC-XLP ) or Trace Anion Concentrator Column (Dionex IonPac TAC-ULP) when a single piston pump such as the Thermo Scientific Dionex AXP Auxiliary Pump (pulse damper required) is used for sample delivery. In addition to the concentrator columns listed above, use the Dionex IonPac UTAC-LP, UTAC-LP or TAC-LP when the sample is delivered using a syringe or a low-pressure autosampler, such as the Thermo Scientific Dionex AS-DV Autosampler. For concentrator work with a. mm capillary column, use the Dionex IonPac AG Capillary Guard Column or the Thermo Scientific Dionex IonSwift MAC- Concentrator Column. SPECIFICATIONS Dimensions: Dionex IonPac AS Analytical Column: mm and mm Dionex IonPac AS Capillary Column:. mm Dionex IonPac AG Guard Column: mm and mm Dionex IonPac AS Capillary Guard Column:. mm Maximum Operating Pressure: psi Mobile Phase Compatibility: ph ; % HPLC solvents Substrate Characteristics: Analytical Column: Supermacroporous resin Bead diameter (μm): Pore Size: Å Cross-linking (%DVB): % Guard Column: Microporous resin Bead Diameter (μm): Pore Size: < Å Cross-linking (%DVB): % Ion-Exchange Group: Functional Group: Alkanol quaternary ammonium ion Functional Group Characteristics: Hydrophobicity: Ultralow Capacity: μeq ( mm column). μeq ( mm column) μeq ( mm column). μeq ( mm column). µeq (. mm column). µeq (. mm column) Column Construction: PEEK with threaded ferrule-style end fittings. All components are nonmetallic.

Ordering Information To order in the U.S., call ---, or contact the Thermo Fisher Scientific office nearest you. Outside the U.S., order through your local Thermo Fisher Scientific office or distributor. Refer to the following part numbers. Description Part Number Dionex IonPac AS Columns Dionex IonPac AS Analytical Column ( mm) Dionex IonPac AG Guard Column ( mm) Dionex IonPac AS Analytical Column ( mm) Dionex IonPac AG Guard Column ( mm) Dionex IonPac AS Capillary Column (. mm) Dionex IonPac AG Capillary Guard Column (. mm) Trace Anion Concentrator Columns Dionex IonPac TAC- Trace Anion Concentrator ( mm) Dionex IonPac TAC-LP Trace Anion Concentrator ( mm) Dionex IonSwift MAC- Monolith Anion Concentrator (. mm) (for use with Capillary IC) Dionex IonPac TAC-LP Trace Anion Concentrator ( mm) Dionex IonPac TAC-ULP Trace Anion Concentrator ( mm) Dionex IonPac UTAC-LP Ultra Trace Anion Concentrator Low-Pressure ( mm) Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Ultra Low-Pressure ( mm) Dionex IonPac UTAC-XLP Ultra Trace Anion Concentrator Extremely Low-Pressure ( mm) Dionex IonPac UTAC-LP Ultra Trace Anion Concentrator Low-Pressure ( mm) Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Ultra Low-Pressure ( mm) Dionex IonPac UTAC-XLP Ultra Trace Anion Concentrator Extremely Low-Pressure ( mm) Anion Eluent Concentrates Dionex IonPac AS Eluent Concentrate ( ), ml Product Specifications www.thermoscientific.com/dionex Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Sunnyvale, CA USA is ISO : Certified. Australia + Austria + Belgium + Brazil + China + Denmark + France + Germany + India + Italy + Japan + Korea + Netherlands + Singapore + Sweden + Switzerland + Taiwan + UK/Ireland + USA and Canada + PS_E /M